• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 99
  • 39
  • 24
  • 17
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • Tagged with
  • 593
  • 100
  • 74
  • 71
  • 60
  • 59
  • 52
  • 49
  • 48
  • 43
  • 39
  • 31
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
441

Simulação dinâmica de uma Torre de Stripper.

PAFFER, Juliana Zeymer Auad. 24 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-24T00:19:47Z No. of bitstreams: 1 JULIANA ZEYMER AUAD PAFFER – DISSERTAÇÃO (PPGEQ) 2015.pdf: 2369945 bytes, checksum: 31ce517399cfe89bebdd0e7c02c68852 (MD5) / Made available in DSpace on 2018-04-24T00:19:47Z (GMT). No. of bitstreams: 1 JULIANA ZEYMER AUAD PAFFER – DISSERTAÇÃO (PPGEQ) 2015.pdf: 2369945 bytes, checksum: 31ce517399cfe89bebdd0e7c02c68852 (MD5) / Um dos efluentes gerados na indústria de cloro e soda é uma corrente ácida (água saturada de cloro). Esta corrente deve passar por um sistema de tratamento antes de ser descartado, devido ao potencial de dano que este pode causar à flora e à fauna marinha, além de infringir as regulamentações ambientais. Visando reduzir o consumo de energia e atender à especificação do efluente, o objetivo deste trabalho é realizar e avaliar a simulação dinâmica de um sistema de tratamento de efluente ácido. O sistema estudado é composto por uma coluna de stripper e um trocador de calor que pré aquece a corrente de alimentação. O estudo se concentrou em avaliar o comportamento do sistema no estado estacionário e dinâmico frente a alterações nas condições de operação do trocador de calor. As simulações foram realizadas no AspenTM e validados com dados da planta industrial. De acordo com os resultados, reduzindo a eficiência de troca de calor do trocador leva no aumento do consumo de energia e o efluente fica fora das especificações. Desta forma, é muito importante manter a eficiência do trocador de acordo com a de projeto e os controladores sintonizados. / One of the effluents generated by chlor-alkali plant is an acid stream (saturated water chlorine). This stream must pass through a treatment system before being discarded because of damage potential that this may cause to the flora and marine fauna, in addition to breaching environmental regulations. In order to reduce energy consumption and meet the effluent specification, the objective is to implement and evaluate the dynamic simulation of an acid wastewater treatment system. The system is composed of a column stripper and a heat exchanger that heats the pre feed stream. The study focused on evaluating the system behavior in the steady state and dynamic against changes in operating conditions of the heat exchanger. The simulations were accomplished by the simulator Aspen™ and validated with data from industrial plant. According to the results, reducing the efficiency of heat exchanger can make the power consumption increase and the effluent is out of specification. This way, it is very important to keep the heat exchange efficiency according to design and tuned controls.
442

Clorina com fotossensibilizador para Terapia Fotodinâmica sobre Streptococcus mutans / Clhorine as photosensibilizer for photodynamic therapy on Streptococcus mutans

Garcia, Maíra Terra 04 May 2018 (has links)
Submitted by MAÍRA TERRA GARCIA null (maa.terra@hotmail.com) on 2018-05-18T19:56:12Z No. of bitstreams: 1 Dissertação Final.pdf: 2946838 bytes, checksum: ea178be5bf5fe9de6d90f99275e65044 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-05-21T17:11:24Z (GMT) No. of bitstreams: 1 garcia_mt_me_sjc.pdf: 2946838 bytes, checksum: ea178be5bf5fe9de6d90f99275e65044 (MD5) / Made available in DSpace on 2018-05-21T17:11:24Z (GMT). No. of bitstreams: 1 garcia_mt_me_sjc.pdf: 2946838 bytes, checksum: ea178be5bf5fe9de6d90f99275e65044 (MD5) Previous issue date: 2018-05-04 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A terapia fotodinâmica (TFD) vem se mostrando eficaz na redução de patógenos bucais e diferentes fotossensibilizadores têm sido investigados. O objetivo desse estudo foi avaliar a eficácia da TFD sobre Streptococcus mutans usando dois fotossensibilizadores derivados da Clorina, Photoditazine (PDZ) e Fotoenticine (FTC), associados à irradiação Laser (660nm, 50 mw/cm²). Esses fotossensibilizadores também foram comparados com o Azul de Metileno (AM) que já tem seus efeitos comprovados contra S. mutans. Para realização desse trabalho, foram isoladas 11 amostras clínicas de S. mutans a partir de pacientes com lesões de cáries ativas. Essas amostras foram identificadas pela Reação em Cadeia da Polimerase (PCR), seguida por confirmação em sequenciamento automático. Também foi incluída no estudo uma cepa padrão de referência (S. mutans UA159). Os efeitos da TFD foram testados sobre S. mutans em culturas planctônicas e sobre biofilmes formados em dentes bovinos. Os resultados foram avaliados pela contagem de células viáveis e Microscopia Eletrônica de Varredura (MEV). A capacidade dos fotossensibilizadores em penetrar nas células de S. mutans foi avaliada por meio da absorbância em espectrofotômetro. Os dados foram analisados por ANOVA e teste de Tukey. Na identificação das amostras, verificou-se que todas apresentaram o fragmento de 517 pb específico para S. mutans e que o sequenciamento demonstrou similaridade de 87% com a cepa de referência. Em culturas planctônicas, todos os fotossensibilizadores reduziram as células de S. mutans com diferença significante em relação ao grupo sem tratamento. O FTC conseguiu atingir 100% de redução tanto para a cepa de referência como para as cepas clínicas. Nos testes em biofilmes, houve redução bacteriana de 4 log para o AM, 6 log para o PDZ e de 5 a 8 log para o FTC. Na cepa padrão de referência, o FTC levou a eliminação total das células de S. mutans. Além disso, verificou-se que o FTC foi o fotossensibilizador com maior capacidade de desestruturar o biofilme e penetrar nas células de S. mutans. Concluiu-se que os fotossensibilizadores derivados da clorina demonstraram maior atividade antimicrobiana na TFD contra S. mutans em relação ao AM, sendo esse efeito mais significativo para o FTC. / A terapia fotodinâmica (TFD) vem se mostrando eficaz na redução de patógenos bucais e diferentes fotossensibilizadores têm sido investigados. O objetivo desse estudo foi avaliar a eficácia da TFD sobre Streptococcus mutans usando dois fotossensibilizadores derivados da Clorina, Photoditazine (PDZ) e Fotoenticine (FTC), associados à irradiação Laser (660nm, 50 mw/cm²). Esses fotossensibilizadores também foram comparados com o Azul de Metileno (AM) que já tem seus efeitos comprovados contra S. mutans. Para realização desse trabalho, foram isoladas 11 amostras clínicas de S. mutans a partir de pacientes com lesões de cáries ativas. Essas amostras foram identificadas pela Reação em Cadeia da Polimerase (PCR), seguida por confirmação em sequenciamento automático. Também foi incluída no estudo uma cepa padrão de referência (S. mutans UA159). Os efeitos da TFD foram testados sobre S. mutans em culturas planctônicas e sobre biofilmes formados em dentes bovinos. Os resultados foram avaliados pela contagem de células viáveis e Microscopia Eletrônica de Varredura (MEV). A capacidade dos fotossensibilizadores em penetrar nas células de S. mutans foi avaliada por meio da absorbância em espectrofotômetro. Os dados foram analisados por ANOVA e teste de Tukey. Na identificação das amostras, verificou-se que todas apresentaram o fragmento de 517 pb específico para S. mutans e que o sequenciamento demonstrou similaridade de 87% com a cepa de referência. Em culturas planctônicas, todos os fotossensibilizadores reduziram as células de S. mutans com diferença significante em relação ao grupo sem tratamento. O FTC conseguiu atingir 100% de redução tanto para a cepa de referência como para as cepas clínicas. Nos testes em biofilmes, houve redução bacteriana de 4 log para o AM, 6 log para o PDZ e de 5 a 8 log para o FTC. Na cepa padrão de referência, o FTC levou a eliminação total das células de S. mutans. Além disso, verificou-se que o FTC foi o fotossensibilizador com maior capacidade de desestruturar o biofilme e penetrar nas células de S. mutans. Concluiu-se que os fotossensibilizadores derivados da clorina demonstraram maior atividade antimicrobiana na TFD contra S. mutans em relação ao AM, sendo esse efeito mais significativo para o FTC. / Photodynamic therapy (PDT) has been shown to be effective in reducing oral pathogens and different photosensitizers have been investigated. The objective of this study was to evaluate the efficacy of PDT on Streptococcus mutans using two photosensitizers derived from Chlorine, Photoditazine (PDZ) and Fotoenticine (FTC) associated with Laser irradiation (660 nm, 50 mw / cm²). These photosensitizers were also compared to Methylene Blue (AM) that already has its proven effects against S. mutans. To perform this work, 11 clinical samples of S. mutans were isolated from patients with active caries lesions. These samples were identified by the Polymerase Chain Reaction (PCR), for confirmation in automatic sequencing. Also included in the study was a standard standard (S. mutans UA159). The effects of PDT were tested on S. mutans in planktonic cultures and on biofilms formed in bovine teeth. Results of viable cell and Scanning Electron Microscopy (SEM) tests. The ability of the photosensitizers to penetrate the S. mutans cells was evaluated by spectrophotometer absorption. Data were analyzed by ANOVA and Tukey's test. In the identification of the samples, all the presentations of the 517 bp fragment specific for S. mutans and that the sequencing demonstrate similarity of 87% with a reference strain were found. In planktonic cultures, all photosensitizers reduced as S. mutans cells with a significant difference in relation to the untreated group. The FTC achieved a 100% reduction for both the reference strain and the clinical strains. In biofilm tests, there was a 4 log reduction for AM, 6 log for PDZ and 5 to 8 log for FTC. In the standard reference strain, FTC led to the complete elimination of S. mutans cells. In addition, it was found that FTC was the photosensitizer with the greatest capacity to de-structure the biofilm and penetrate S. mutans cells. It was concluded that the photosensitizers derived from chlorine showed a greater antimicrobial activity in PDT against S. mutans in relation to AM, being this effect more significant for the FTC. / 2016/09296-8
443

Diafragmas de PEUAPM para aplicação no processo de produção eletrolítica de cloro-soda.

VIANA, Kaline Melo de Souto. 27 September 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-09-27T18:51:38Z No. of bitstreams: 1 KALINE MELO DE SOUTO VIANA – TESE (PPGEP) 2006.pdf: 3746935 bytes, checksum: 4a030ab6637f715855808519f3e7825e (MD5) / Made available in DSpace on 2018-09-27T18:51:38Z (GMT). No. of bitstreams: 1 KALINE MELO DE SOUTO VIANA – TESE (PPGEP) 2006.pdf: 3746935 bytes, checksum: 4a030ab6637f715855808519f3e7825e (MD5) Previous issue date: 2009-02-06 / Para a avaliação de diafragmas alternativos ao de amianto para produção de cloro e soda cáustica a partir da eletrólise da salmoura, foi utilizada uma célula eletroquímica em escala de bancada pelo processo diafragma. O objetivo foi investigar a possível substituição dos diafragmas de amianto por diafragmas de PEUAPM. Desta forma, este trabalho foi dividido em duas etapas. Na primeira etapa, foi realizada a investigação da resistência química do PEUAPM na forma de fibras, em meio ácido, básico e salino, numa temperatura de 90ºC, simulando-se as condições de operação das células eletroquímicas para produção cloro-soda. Para isto, foram utilizados os ensaios de infravermelho (FTIR), calorimetria diferencial exploratória (DSC), tração e microscopia eletrônica de varredura (MEV). Na segunda etapa, foram realizadas eletrólises e para isto foram confeccionados diafragmas com diferentes composições, variando de 100% amianto (diafragma utilizado como referência), passando pelo balanço de 5:95 a 90:10% de PEUAPM:amianto, até 100% PEUAPM. Para caracterização eletroquímica utilizou-se a determinação do número de MacMullim, bem como determinação dos parâmetros operacionais após 72 horas de eletrólise, numa temperatura de aproximadamente 85ºC, onde foram quantificados os seguintes parâmetros: eficiência de corrente, eficiência de energia, teor de cloretos e teor de cloratos, com o objetivo de correlacionar os dados obtidos com o novo diafragma aos dados obtidos com o diafragma de amianto (utilizado industrialmente). As condições operacionais utilizadas foram: diafragma de amianto, PEUAPM: amianto e PEUAPM, alimentação contínua de uma salmoura ácida (pH entre 3,5 e 4,0) na concentração de 320 g/L, densidade de corrente anódica de 2,63 KA/m2 com um tempo total de operação da célula eletrolítica na intensidade de corrente de 13,1 A de aproximadamente 72 horas, até atingir a concentração de 12% de NaOH (de acordo com os parâmetros industriais). Os resultados obtidos na etapa I, evidenciaram que as fibras de PEUAPM apresentam boa resistência ao ataque químico das soluções de NaCl, HCl e salmoura na temperatura de 90ºC, durante as 96 horas de exposição, apresentando apenas um início de oxidação, detectada pela presença de carbonilas, além de uma redução de 15% na cristalinidade das fibras de PEUAPM. Já por meio dos resultados obtidos na etapa II, observou-se que os diafragmas amianto/PEUAPM estudados não apresentaram bom empacotamento de fibras e que há uma tendência de redução da eficiência de corrente (E.C.) e eficiência de energia (E.E.) com o aumento do percentual de PEUAPM. Assim, conclui-se que as fibras de PEUAPM são um substituto em potencial para as fibras de amianto na produção cloro-soda. / To evaluate the alternatives diaphragm in relation to the asbestos in the chloro-alkali production from the electrolysis of brine, it was used an electrochemical cell in a laboratory scale by diaphragm process. The aim of this work is to study the substitution of asbestos diaphragm by UHMWPE. So, this work was divided in two steps. Firstly, it was done an investigation related to the chemical resistance of the UHMWPE in a fiber shape and in acid, base and salty solutions and 90oC of temperature. This condition was similar to the electrochemical cell operation in the chloro-alkali industry. It was used test of infrared (FTIR), differential scanning calorimetry (DSC), tensile strength and scanning electron microscopy (SEM) to evaluate the UHMWPE fibers. In the second step it was done the electrolysis with different compositions of diaphragm, changing from 100% of asbestos (used as reference) to 5:95, 90:10% of UHMWPE, until 100% of UHMWPE. To chemical characterization it was estimated the MacMullin number, as well the operational cell parameters, such as, current and energy efficiency, amounts of chlorates and chlorides. The aim of to study these parameters is the correlate the new diaphragm with the asbestos (used currently in the industry). The operational conditions used in this study were: continue feed of acid brine (pH from 3.5 to 4.0), concentration of 320 g/L, anodic current density of 2.63 KA/m2, and total time operation in the electrolytic cell of approximately 74 ho urs (current intensity of 13.1A) until reach 12% of NaOH concentration (similar to the industrial conditions). The results obtained in the first step showed that the UHMWPE fibers presented good resistance to the chemical attack of NaCl, HCl and brine solution at 90oC and in the period of 96 hours of exposition. It was observed only an start of oxidation, with presence of carbonyl groups, also it was observed an decrease in 15% in the crystallinity of the UHMWPE fibers. From the results of the second step it was observed that the asbestos/UHMWPE diaphragms studied presented good fiber packing and a tendency to decrease current and energy efficiencies with the increase of the UHMWPE content. So, it was concluded that with the conditions of preparation of asbestos/UHMWPE diaphragm done in this study the use of these in the choro-alkali production still limited due to the low surface energy and physical interaction presented by the UHMWPE fibers and it was necessary an previous surface treatment of the fibers.
444

Spatiella mönster och lager av organiskt klor och klorid i barrskogsjord i sydöstra Sverige / Spatial patterns and storage of organic chlorine and chloride in coniferous forest soil in south-east Sweden

Wesström, Karin January 2002 (has links)
The concentration and storage of organic chlorine and chloride were determined in soil, to a depth of 40 cm, in a coniferous forest in the Stubbetorp catchment area in south-east Sweden. Also, the spatial distribution of the two forms of chlorine was determined. Soil samples were collected at 49 of the nodes in a grid with approximately 105 m between the nodes. The analysis of spatial variability suggested that no spatial autocorrelation was present either within the variable organic chlorine or chloride. This means that no sample was more influenced by another nearby sample, as compared to other samples further away. Instead, linear interpolation was used to construct contour maps of the concentrations. The contour maps indicated that the two forms of chlorine have similar spatial patterns and the highest concentrations could be found in the main valley area, with moss soil and forest dominated by pine (Pinus sylvestris (L.)). The two variables showed a significant positive correlation. This could be due to the fact that chloride is the limiting factor for formation in Swedish soil or that the two forms of chlorine are only indirectly related through variables as soil moisture or organic matter. The storage of organic chlorine when a depth of 40 cm was taken into account was seven times the storage compared to an earlier study where only the top-soil was sampled. The storage of organic chlorine in the area is of such size that changes in this storage are likely to have an impact on the transport of chloride. The fact that no spatial autocorrelation could be found in either of the variables suggests that the scale chosen is not suitable for describing spatial autocorrelation on a smaller level, due to processes e.g. microbially induced formation. At the same time the chosen scale is probably too small for detecting spatial autocorrelation on the larger scale due to e.g. deposition and precipitation.
445

Decaimento da concentração de cloro residual livre nas redes de abastecimento de água / Determination of concentration of free residual chlorine in water supply networks

Oliveira, Luciano de 13 July 2018 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-13T11:23:42Z No. of bitstreams: 2 Dissertação - Luciano de Oliveira - 2018.pdf: 5027134 bytes, checksum: a0469fdd822b10eda9e451f4b9c889b2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-13T11:51:19Z (GMT) No. of bitstreams: 2 Dissertação - Luciano de Oliveira - 2018.pdf: 5027134 bytes, checksum: a0469fdd822b10eda9e451f4b9c889b2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-08-13T11:51:19Z (GMT). No. of bitstreams: 2 Dissertação - Luciano de Oliveira - 2018.pdf: 5027134 bytes, checksum: a0469fdd822b10eda9e451f4b9c889b2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-07-13 / The chlorination process is the most used to promote disinfection of water intended for human consumption. During the course of chlorinated water in the supply systems, the concentration of free residual chlorine (FRC), whose reaction rate depends on the characteristics of the natural water, occurs. In this work, we studied the decay of the FRC concentration related to the reactions in the liquid mass in two types of water, of subterranean and superficial origin, with different concentrations of organic matter, with the perspective of the influence of the water travel time, dependent on consumption scenarios in real distribution networks, whose supply modules are characterized by low population density and that operate under the initial demand conditions predicted in the projects. The effect of temperature and total organic carbon on the values of mass decay kinetic constants (k b ), used in mathematical models that simulate water quality, was considered. The results showed that the variation of the kb values is directly proportional to the water temperature and the TOC. For initial concentrations close to 1.00 mg.L -1 , the values of the kinetic constants for waters from surface water sources maintained in the temperature ranges of 20 to 21 °C and 30 to 31 °C were respectively 0.0888 day -1 and 0.1200 day -1 for samples collected at the ETA filter output of the DAIAsystem and TOC value of 0.4798 mg.L -1 and equal to and 0.1680 day -1 and 0.3024 day -1 for the samples collected at the filter outputs of the Piancó and TOC system ETA of 0.8750 mg.L - . In samples of groundwater with TOC of 0.1740 mg.L -1 , maintained at the same temperature 1 ranges, the kinetic coefficients were 0.0264 day -1 and 0.0480 day -1 , respectively. Experiments for temperature between 30 and 31 °C and near test duration showed a significant difference in chlorine decay behavior in filtered water samples collected at conventional treatment plants, which showed a residual chlorine loss percentage of 64.81% in relation to the initial concentration of 1.08 mg.L -1 of disinfectant (ETA DAIA) and 33.65% in relation to the initial concentration of 1.05 mg.L -1 of disinfectant (ETA Piancó). Raw water samples from the underground spring lost 14.33% of the initial concentration of 1.04 mg.L -1 . The travel times for the most critical nodes and the minimum disinfectant concentrations at the entrance of the supply modules to comply with the legislation were 40 hours and 0.27-0.28 mg.L -1 for the distribution networks of the condominium Valley of the Birds and 144 hours and 0.30-0.36 mg.L -1 for the condominium Terras Alphaville. / O processo de cloração é o mais utilizado para promover a desinfecção das águas destinadas ao consumo humano. Durante o percurso da água clorada nos sistemas de abastecimento ocorre o decaimento da concentração do cloro residual livre (CRL), cuja taxa de reação depende das características da água natural. Neste trabalho estudou-se o decaimento da concentração do CRL relacionado às reações na massa líquida em dois tipos de águas, de origem subterrânea e superficial, com diferentes concentrações de matéria orgânica, com aperspectiva da influência do tempo de percurso da água, dependente de cenários de consumo em redes de distribuição reais, cujos módulos de abastecimento são caracterizados pelo baixo adensamento populacional e que operam nas condições iniciais de demanda previstas nos projetos. Considerou-se o efeito da temperatura e do carbono orgânico total sobre os valores das constantes cinéticas de decaimento em massa (k b ), utilizadas nos modelos matemáticos que simulam a qualidade da água. Os resultados mostraram que a variação dos valores de k b é diretamente proporcional à temperatura da água e ao COT. Para concentrações iniciais próximas a 1,00 mg.L -1 os valores das constantes cinéticas, para águas provenientes de mananciais superficiais mantidas nas faixas de temperatura de foram, respectivamente, iguais a 0,0888 20 a 21 °C e 30 a 31 °C, dia -1 e 0,1200 dia -1 para amostras coletas na saída do filtro da ETA do sistema DAIA e valor de COT de 0,4798 mg.L -1 e iguais a e 0,1680 dia -1 e 0,3024 dia -1 para as amostras coletas na saídas do filtro da ETA do sistema Piancó e COT de 0,8750 mg.L -1 . Em amostras de água subterrânea com COT de 0,1740 mg.L -1 , mantidas nas mesmas faixas de temperatura, os coeficientes cinéticos foram iguais a 0,0264 dia -1 e 0,0480 dia -1 , respectivamente. Os experimentos para temperatura entre 30 e 31 °C e tempos próximos de duração dos testes demonstraram diferença significativa no comportamento do decaimento do cloro em amostras de água filtrada coletadas nas estações de tratamento convencional que apresentaram porcentagem de perda de cloro residual de 64,81 % em relação à concentração inicial de 1,08 mg.L -1 de desinfetante (ETA DAIA) e 33,65 % em relação à concentração inicial de 1,05 mg.L -1 de desinfetante (ETA Piancó). Amostras de água bruta do manancial subterrâneo perderam 14,33 % da concentração inicial de 1,04 mg.L -1 . Os tempos de percurso para os nós mais críticos e as concentrações mínimas de desinfetante na entrada dos módulo de abastecimento para atendimento à legislação foram iguais a 40 horas e 0,27-0,28 mg.L -1 para as redes de distribuição do condomínio Vale dos Pássaros e 144 horas e 0,30-0,36 mg.L -1 para o condomínio Terras Alphaville.
446

Aplicacao do processo avancado de oxidacao por feixe de eletrons na degradacao de compostos organicos presentes em efluentes industriais

DUARTE, CELINA L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:56Z (GMT). No. of bitstreams: 1 06654.pdf: 9860874 bytes, checksum: a9212efd0462f2603abb2f237d62a703 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
447

Estudos da influência de surfactantes e determinação de cloro em água potável empregando-se TCPO e 2-NPO / Studies of the influence of surfactants and determination of chlorine in drinking water using TCPO and 2-NPO

Margareth Mie Nakamura Matsuda 16 September 2003 (has links)
As reações quimiluminescentes de oxalato de bis(2,4,6-triclorofenila) (TCPO) e oxalato de bis(2-nitrofenila) (2-NPO), com f1uoranteno como f1uoróforo, em sistemas micelares aquosos, foram estudadas na presença de alguns surfactantes. A oxidação destes oxalatos por peróxido de hidrogênio ou por hidroperóxido de t - butila produz quimiluminescência cuja intensidade depende da acidez e da presença de imidazol. A intensidade de quimiluminescência é maior na presença de alguns surfactantes, especialmente CTAC, OTAC, DDAB, DODAC e β-ciclodextrina. A reação de TCPO com cloro (HCIO, CIO- e Cl2) na presença de 9,10-difenilantraceno como fluoróforo, em meio de acetonitrila/água, também foi investigada. Um sistema de análise por injeção em fluxo para determinação de cloro com aplicação analítica em água de torneira foi desenvolvido. A faixa linear para a curva analítica de cloro e o limite de detecção foram, respectivamente: (0,2 - 3,0)x10-5 e 0,2 x10-5 mol L-1. / The chemiluminescent reactions of bis (2,4,6-trichlorophenyl) oxalate (TCPO) and bis(2-nitrophenyl) oxalate (2-NPO), with fluoranthene as fluorophore, in aqueous micellar systems, were studied in the presence of surfactants. The oxidation of these oxalates by hydrogen peroxide or t-butyl peroxide produces chemiluminescence, which depends on the acidity and imidazole presence. The chemiluminescent intensity is higher in the presence of some surfactants, especially CTAC, OTAC, DDAB, DODAC and β-cyclodextrine. The reaction of TCPO with free chlorine (HCIO, CIO- and Cl2), in the presence of 9,10-diphenylanthracene as fluorophore in acetonitrile/water medium, was also investigated. A flow injection analysis system, for free chlorine determination with analytical application in tap water was developed. The linear range for free chlorine and detection limit were, respectively: (0.2-3.0)x10-5 and 0.2x10-5 mol L-1.
448

Desinfestação e estabelecimento in vitro de segmentos caulinares de camu-camuzeiro / Disinfestation and in vitro establishment of stem segments of camu-camu tree

Maria da Conceição da Rocha Araújo 02 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O camu-camuzeiro (Myrciaria dubia (H. B. K.) McVaugh) é uma espécie frutífera pertencente à família Myrtaceae, de ocorrência espontânea nas margens de rios e lagos da Amazônia. Apresenta potencial econômico, uma vez que o fruto é considerado a maior fonte natural de vitamina C, chegando a atingir 6112 mg de ácido ascórbico por 100 g de polpa, despertando interesse comercial por parte dos produtores e consumidores. Apesar da importância econômica, pouco se sabe sobre os aspectos da multiplicação in vitro desta espécie, o que poderia elevar significativamente a sua produtividade. Neste sentido, objetivou-se com o presente trabalho testar diferentes concentrações de produtos pra desinfestação e estabelecimento de uma cultura asséptica, utilizando explantes de segmentos caulinares de camu-camu provenientes de plantas mães, mantidas em ambiente ex vitro. O trabalho foi dividido em quatro experimentos: 1) Avaliação do efeito do hipoclorito de sódio na assepsia dos explantes de segmentos caulinares de camu-camu in vitro; 2) Avaliação de diferentes concentrações de cloreto de mercúrio na desinfestação in vitro de segmentos caulinares de camu-camu; 3) Determinação da melhor concentração e tempo de imersão de dióxido de cloro na desinfestação in vitro de segmentos caulinares de camu-camu; 4) Uso de antibióticos para o controle da contaminação bacteriana em culturas in vitro de segmentos caulinares de camu-camu. Após 30 dias, avaliou-se o percentual de contaminação e a porcentagem de explantes estabelecidos. A utilização de hipoclorito de sódio a 1,5 % de cloro ativo, por 12 minutos, proporcionou maiores porcentagens de descontaminação (98%), o que resultou na obtenção de bons índices de estabelecimento (87,9%). O cloreto de mercúrio mostrou-se tóxicos aos explantes, mesmo nas menores concentrações. Com a utilização do dióxido de cloro na concentração de 50%, em exposição no tempo de 30 minutos, obteve-se 60% dos explantes desinfestados e 60% estabelecidos. Quanto aos antibióticos, menores índices de contaminação e maiores de estabelecimento (0% e 50% respectivamente) foram obtidos quando utilizou ampicilina na concentração de 100 mg.L-1. Portanto, para desinfestação in vitro de camu-camuzeiro, via segmentos caulinares, deve-se utilizar hipoclorito de sódio a 1,5 % por 12 minutos, com adição no meio de cultura de 100 mg.L-1 de antibiótico ampicilina. / The camu-camu tree (Myrciaria dubia (H.B.K.) McVaugh) is a fruit-bearing species belonging to the family Myrtaceae of spontaneous occurrence on the banks of rivers and lakes of Amazonia. It presents economic potential, since its fruits are thought the greatest natural source of vitamin C, bordering 6,112g of ascorbic acid per 100 g of pulp, arising commercial interest on the part of the farmers and consumers. In spite of the economic importance, little is known about the aspects of the in vitro multiplication of this species, which could raise significantly its yield. In this sense, it was aimed through this work to test different concentrations of products for disinfestation and establishment of an aseptic culture by utilizing explants of stem segments of camu-camu coming from mother plants kept in ex vitro environment. The work was divided into four experiments: 1) evaluation of the effect of sodium hypochlorite upon the asepsis of the explants of stem segments of camu-camu in vitro; 2) to evaluate different concentrations of mercury chlorite in the in vitro disinfestation of camu-camu stem segments; 3) to determine the best concentration and immersion time of chlorine dioxide in the in vitro disinfestations of camum-camu stem segments; 4) Use of antibiotics for the control of bacterial contamination in in vitro cultures of camu-camu stem segments. After 30 days‟ time, the percent of contamination and the percentage of established explants were evaluated. The use of sodium hypochlorite at 1.5%of active chlorine for 12 minutes provided highest percentages of decontamination (98%), which resulted into the obtaining of good establishment indices (87.9%). Mercury chlorite proved toxic to the explants even at the lowest concentrations. Through the use of chlorine dioxide at the concentration of 50% under exposition in the 30 minutes‟ time, 60% of the disinfected explants and 50% of the established ones were obtained. As to the antibiotics, decreased contamination indices and increased establishment indices (0% and 50%, respectively) were reached when ampicillin at the concentration of 100 mg/ L was utilized. Therefore, for in vitro disinfection of camu-camu tree via stem segments, one should utilize 1.5% sodium hypochlorite for 12 minutes, with addition in the culture medium of 100 mg/ L of antibiotic ampicillin.
449

Remoção de atividade estrogênica do hormônio 17β-Estradiol em processos de oxidação de águas para abastecimento / Removal of estrogenic activity of the hormone 17β-estradiol in oxidation processes for drinking water

Paulo Rogério Martins da Silva 25 October 2013 (has links)
Muitos oxidantes químicos reativos acarretam na ruptura de estruturas moleculares complexas de vários tipos de compostos orgânicos decompondo-as em estruturas mais simples e propiciando condições melhores para uma efetiva ação de micro-organismos na degradação biológica. A presença de hormônios, entre eles o 17β-estradiol, em estações de tratamento de esgoto e em águas subterrâneas e superficiais mostra a necessidade de uma avaliação dos processos de tratamento convencionais. O objetivo deste trabalho foi a análise e remoção de hormônios através de técnicas de cloração e ozonização de amostras reais de águas de saída de filtro de estações de tratamento de água (ETAs), operadas pelo Serviço Autônomo de Água e Esgoto (SAAE) de São Carlos (ETA Centro), que capta águas dos ribeirão Feijão e córrego Espraiado e pela Sociedade de Abastecimento de Água e Saneamento S/A (SANASA) de Campinas (ETAs 3 e 4), que capta águas do rio Atibaia. Foram realizados ensaios contaminando-se as amostras com 17β-estradiol, que é o hormônio natural mais presente no meio ambiente, em concentração de 6.000 ng L-1, submetendo-se tratamento com dosagens em torno de 0,5 e 2,0 mg L-1 desses oxidantes, em tempos de contato de, respectivamente, 10 e 30 min. As amostras submetidas à contaminação e tratamento e as de controle (sem contaminação e tratamento) foram analisadas através da remoção do 17β-estradiol com a verificação da atividade estrogênica das amostras por ensaios de Sistema de Expressão de Estrogênio Induzida por Levedura Bioluminescente (BLYES), que apresentou-se como uma ferramenta simples. Os resultados apresentados neste trabalho demonstram que a oxidação por ozônio se mostrou mais eficiente do que aquela por cloro para a remoção da atividade estrogênica causada, única e exclusivamente, pelo 17β-estradiol para uma dosagem inicial desse hormônio relativamente alta (6.000 ng L-1). Todavia, em todos os ensaios a concentração final da atividade estrogênica permaneceu acima do limite de quantificação desses hormônio, indicando que a remoção não foi completa, mesmo em condições favoráveis, isto é, matriz limpa, com padrões de potabilidade para os parâmetros físico-químicos. / Many reactive chemical oxidants cause the disruption of the complex molecular structures of various types of organic compounds decomposing them into simpler structures and providing better conditions for effective action of micro-organisms in the biological degradation. The presence of hormones, including 17β-estradiol in sewage treatment plants and groundwater and surface water shows the need for an evaluation of conventional treatment processes. The aim of this study was the analysis and removal of hormones through techniques of chlorination and ozonation of real samples of output filter water in water treatment plants (WTP), operated by the Serviço Autônomo de Água e Esgoto (SAAE) of São Carlos (Center WTP), which captures waters from Espraiado stream and Feijão stream and the Sociedade de Abastecimento de Água e Saneamento S/A (SANASA) de Campinas (WTPs 3 and 4), which captures water from the Atibaia river. Assays were performed contaminating the samples with 17β-estradiol, which is the natural hormone more present in the environment, in a concentration of 6.000 ng L-1 submitting themselves to treatment with dosages of around 0.5 to 2.0 mg L-1 of these oxidants in times of contact, respectively, 10 and 30 min. The samples subjected to contamination and treatment and control samples (without contamination and treatment) were analyzed by removing 17β-estradiol with estrogenic activity verification of the samples by Bioluminescent Assays or Estrogen-Inducible Yeast Expression System (BLYES), which was presented as a simple tool. The results presented here demonstrate that the oxidation by ozone was more effective than with chlorine to remove estrogenic activity caused solely by 17β-estradiol for an initial dosage of the hormone relatively high (6000 ngL -1) However, in all experiments the final concentration of estrogenic activity remained above the limit of quantification of these hormones, indicating that removal was not complete, even under favorable conditions, clean matrix with quality for drinking water physico-chemical parameters.
450

Estudo dos parâmetros do decaimento do cloro residual em sistema de distribuição de água tratada considerando vazamento / Study of the residual decay parameters in water distribution systems with leakage

Sérgio Ricardo Toledo Salgado 15 February 2008 (has links)
O uso do cloro como desinfetante em sistemas de água para abastecimento é prática comum nas estações de tratamento de água. Introduzido durante o processo de tratamento, o cloro participa de diversas reações com compostos de naturezas orgânicos e inorgânicos no interior das tubulações. Tais reações ocorrem na massa líquida e junto às paredes das tubulações e são responsáveis pelo decaimento do cloro ao longo das redes. Visualizando a modelagem como uma ferramenta eficiente para gerenciar o cloro residual em sistemas de distribuição de água, muitos estudos foram realizados e reportados pela literatura, assumindo que os efeitos de decaimento de cloro podem ser bem representados pelos coeficientes kb e kw. Entretanto, a determinação de valores para parâmetros em questão não é uma tarefa fácil, devido à complexidade dos sistemas enfocados em termos da diversidade de materiais das tubulações e mananciais (superficiais e subterrâneos). No Brasil, apesar de legislação recente estabelecer limites restritivos para o cloro na água potável (após desinfecção, a concentração de cloro deve observar a concentração mínima de 0,5 mg/L, sendo o mínimo nível aceito em sistemas de distribuição de 0,2 mg/L e o máximo de 2,0 mg/L), poucos estudos enfocam a avaliação dos parâmetros de decaimento. Esta pesquisa apresenta a aplicação de um modelo inverso elaborado para determinar a ordem para o modelo de decaimento do cloro e os valores globais e/ou locais para o kb e o kw. Sendo programado com o suporte do simulador de EPANET 2 (toolkit) e os algoritmos genéticos como ferramenta de otimização, implementado através da biblioteca de GAlib C++. Os estudos foram realizados em dois sistemas reais da distribuição da água em que foram considerados parâmetros globais e parâmetros específicos da qualidade. Para a investigação da determinação de parâmetros de decaimento de cloro em sistemas de distribuição com vazamento em função da pressão, foi adotada uma rede hipotética com três fontes de cloro. Esse sistema permitiu a calibração e a validação do modelo, assim como a avaliação da influência hidráulica na determinação dos resultados de qualidade de água. / The use of chlorine as disinfectant in water supply systems has been a common practice adopted by the water industry. Introduced during the treatment process, chlorine participates in several reactions with compounds of organic and inorganic nature inside the pipes. Such reactions that occur in the bulk and the wall of the pipes are responsible for chlorine decay along the networks. Visualizing the modeling as an efficient tool to manage the chlorine residual in water distribution systems, many studies have been conducted and reported by the literature, assuming that the chlorine decay effects can be well represented by the decay coefficients kb and kw. However, the determination of values for theses parameters is not an easy task, due to the complexity of the focused systems in terms of pipe materials and water supply sources diversity (surface water and groundwater). In Brazil, instead of recent legislation stating more strict limits for chlorine in drinking water (after disinfection, chlorine concentration has to observe the minimum concentration of 0.5 mg/L, being the minimum accepted level in the distribution system of 0.2 mg/L and the maximum of 2.0 mg/L), few studies focus on the evaluation of the decay parameters. This research reports the application of an inverse model built to determine the order for chlorine decay model and the global and/or local values for kb and kw. It is codified with the support of EPANET 2 (Toolkit) simulator and technology of genetic algorithms as optimization tool, which is implemented by using the GAlib C++ library. The studies were conducted on two real water distribution systems considering both global and specific quality parameters. A hypothetical network with three sources of chlorine was studied too, admitting leakage as pressure function. This system permitted both calibration and validation of the model as well as the evaluation of hydraulic calibration influence on the water quality results.

Page generated in 0.0352 seconds