• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 99
  • 39
  • 24
  • 17
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • Tagged with
  • 593
  • 100
  • 74
  • 71
  • 60
  • 59
  • 52
  • 49
  • 48
  • 43
  • 39
  • 31
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Understanding the origin of 35/37Cl and 16/18O isotope effects on 195Pt and 103Rh NMR nuclear shielding in selected Pt(IV) and Rh(III) complexes : a DFT study

Davis, John Christopher 12 1900 (has links)
Thesis (PhD)--Stellenbosch University, 2013. / Please refer to full text to view abstract.
412

Synthèse des ferrates (VI) de métaux alcalins en utilisant le chlore comme oxydant / Synthesis of alkaline metal ferrates (VI) by using chlorine as oxydant

Ostrosi, Etleva 15 October 2007 (has links)
Ce travail est focalisé sur la synthèse par voie sèche des ferrates de métaux alcalins (A2FeVIO4, A = K, Na) en utilisant le chlore comme oxydant. Les ferrates (VI) sont des composés qui contiennent du fer sous son état d’oxydation +6. Leur importance s’avère grandissante dans le traitement des eaux et des effluents industriels du fait de la nature multifonctionnelle du FeVI. Bien que l’existence de ferrates alcalins soit citée depuis un siècle, ceux-ci n’ont pas fait l’objet d’un nombre considérable d’études. Ceci est principalement du à leur instabilité et aux difficultés concernant les méthodes de préparation. La synthèse de ferrates alcalins dans le réacteur rotatif a été réalisée à température ambiante et la réaction totale de synthèse fut exothermique. Pour les expériences effectuées, des quantités de réactants solides (sel de fer + AOH) allant de quelques dizaines de grammes jusqu’à 400 grammes ont été utilisées. Les effets de différents paramètres sur le déroulement de la synthèse ont été étudiés. Afin d’améliorer le processus de synthèse et appliquer l’extrapolation industrielle, la synthèse de ferrates a été réalisée au sein d’un réacteur à lit fluidisé. Le procédé consiste premièrement, à mélanger préalablement l’hydroxyde de sodium (NaOH) avec le sulfate ferreux (FeSO4?H2O) et deuxièmement, à fluidiser le mélange obtenu en présence du chlore dilué. L’application de ce procédé permet d’atteindre un rendement en FeVI d’environ 56 %. Les résultats obtenus témoignent d’un processus propre et innovant et d’un faible coût pour la synthèse des ferrates de métaux alcalins à plus grande échelle / This work is focused on the dry method synthesis of alkaline metal ferrates (A2FeVIO4, A = K, Na) by using chlorine as oxidant. The ferrates (VI) are compounds which contain iron under its oxidation state +6. They gain growing importance in the industrial effluent and water treatment because of multipurpose nature of FeVI. Although the existence of alkaline ferrates has been mentioned for one century, the alkaline ferrates were not the subject of a considerable number of studies. This is mainly due to their instability and difficulties concerning the methods of preparation. The alkaline ferrate synthesis in the rotary reactor was carried out at room temperature and the whole reaction of synthesis was exothermic. For the realized tests of synthesis, solid quantities of (iron salt + AOH) of a few tens of grams up to 400 grams were used. The effects of various parameters on the synthesis process were studied. In the perspective of improving the process of synthesis and applying the industrial extrapolation, the synthesis of ferrate was realised in a fluidized bed reactor. The proceeding occurs by two successive steps: the first consisting in mixing beforehand the sodium hydroxide with ferrous sulphate and the second to fluidize the mixture obtained in the presence of diluted chlorine. The application of this process makes possible to attain a yield in FeVI of about 56 % and the results obtained show a clean and innovative process of low cost for the synthesis of alkaline metal ferrates on a large scale
413

Uso perioperatório de solução cristaloide balanceada comparado ao de cloreto de sódio 0,9% em crianças submetidas à ressecção de tumor cerebral: ensaio clínico randomizado / Perioperative use of a balanced crystalloid solution versus saline in children undergoing brain tumor resection: a randomized clinical trial

Neville, Mariana Fontes Lima 07 December 2018 (has links)
Objetivo: O objetivo deste estudo foi avaliar se o uso de uma solução cristaloide balanceada induz menos alterações metabólicas do que o cloreto de sódio 0,9% em crianças submetidas à ressecção de tumor cerebral. Desenho: Estudo fase II, unicêntrico, de superioridade, randomizado e controlado, realizado no Instituto de Oncologia Pediátrica da Universidade Federal de São Paulo, Brasil. População: crianças com idade entre 6 meses e 12 anos submetidas à ressecção de tumor cerebral. Intervenção: O uso de uma solução cristaloide balanceada durante e após (por 24 horas) ressecção de tumor cerebral foi comparado ao uso de cloreto de sódio 0,9%. Eletrólitos séricos e gasometria arterial foram coletados em três momentos: antes da cirurgia (basal); após a cirurgia [pós-operatório imediato (POI)]; e no primeiro dia pós-operatório (1º DPO). Desfecho primário: O desfecho primário deste estudo foi a variação do cloro sérico (pós-préop Cl), definida como a diferença absoluta entre as concentrações plasmáticas medidas no POI e antes da cirurgia. Desfechos secundários: Como desfechos secundários, foram avaliadas as variações (pós-préop) dos outros eletrólitos e do excesso de bases (BE); a incidência de acidose hiperclorêmica; e o escore de relaxamento cerebral (ERC), avaliado pelo neurocirurgião por meio de escala de 4 pontos. Resultados: 53 pacientes foram incluídos no estudo e randomizados; 27 receberam solução balanceada (grupo SB) e 26, cloreto de sódio 0,9% (grupo NaCl 0,9%). O pós-préop Cl mediano foi significativamente menor no grupo SB [0 (-1,0; 3,0)] do que no grupo NaCl 0,9% [6 (3,5; 8,5)], p < 0,01. O pós-préop BE mediano foi menor [-0,4 (-2,7; 1,3) versus -4,4 (-5,0; -2,3), p < 0,01] e acidose hiperclorêmica menos frequente (4% versus 67%, p < 0,01) no grupo SB do que no grupo NaCl 0,9%. O ERC foi comparável entre os grupos. Conclusão: Em crianças submetidas à ressecção de tumor cerebral, o uso de solução cristaloide balanceada reduziu a variação do cloro sérico comparado ao uso de cloreto de sódio 0,9%. Esses achados respaldam o uso de soluções balanceadas em crianças submetidas à ressecção de tumor cerebral. Registro no Clinical Trials: NCT NCT02707549 / Objective: The aim of this study was to determine if the use of a balanced crystalloid induces less metabolic derangements than 0.9% saline solution in children undergoing brain tumor resection. Design: Phase II, single center, superiority, randomized and controlled trial performed at Instituto de Oncologia Pediátrica, Universidade Federal de São Paulo, São Paulo, Brazil. Population: Pediatric patients (age range, 6 months to 12 years) undergoing brain tumor resection. Intervention: Use of a balanced crystalloid solution during and after (for 24 h) brain tumor resection was compared to saline 0.9%. Serum electrolyte and arterial blood gas analyses were performed before surgery (baseline), after surgery, and at postoperative day 1. Primary outcome: The primary trial outcome was the preoperative to postoperative variation in serum chloride (post-preop Cl) measured as the absolute difference between \"after surgery\" and baseline plasma concentrations. Secondary outcomes: As secondary outcomes, we measured the post-preop of other electrolytes and base excess (BE); hyperchloremic acidosis incidence; and the brain relaxation score, a four-point scale evaluated by the surgeon for assessing brain edema. Results: Fifty-three patients were included in the study; twenty-seven were randomized to receive a balanced crystalloid (balanced group) and twenty-six were randomized to receive 0.9% saline solution (saline group). The median post-preop Cl (mmol l-1) was significantly lower in the balanced [0 (-1.0; 3.0)] than in the saline group [6 (3.5;8.5); p < .01]. Median post-preop BE (mmol l-1) was lower [-0.4 (-2.7; -1.3) versus -4.4 (- 5.0; -2.3); p < .01] and hyperchloremic acidosis less frequent (4% versus 67%; p < .01) in the balanced group than in the saline group. Brain relaxation score was comparable between groups. Conclusions: In children undergoing brain tumor resection, balanced crystalloid solution infusion reduced variation in serum chloride. These findings support the use of balanced crystalloid solutions in children undergoing brain tumor resection
414

Estudos da influência de surfactantes e determinação de cloro em água potável empregando-se TCPO e 2-NPO / Studies of the influence of surfactants and determination of chlorine in drinking water using TCPO and 2-NPO

Matsuda, Margareth Mie Nakamura 16 September 2003 (has links)
As reações quimiluminescentes de oxalato de bis(2,4,6-triclorofenila) (TCPO) e oxalato de bis(2-nitrofenila) (2-NPO), com f1uoranteno como f1uoróforo, em sistemas micelares aquosos, foram estudadas na presença de alguns surfactantes. A oxidação destes oxalatos por peróxido de hidrogênio ou por hidroperóxido de t - butila produz quimiluminescência cuja intensidade depende da acidez e da presença de imidazol. A intensidade de quimiluminescência é maior na presença de alguns surfactantes, especialmente CTAC, OTAC, DDAB, DODAC e &#946;-ciclodextrina. A reação de TCPO com cloro (HCIO, CIO- e Cl2) na presença de 9,10-difenilantraceno como fluoróforo, em meio de acetonitrila/água, também foi investigada. Um sistema de análise por injeção em fluxo para determinação de cloro com aplicação analítica em água de torneira foi desenvolvido. A faixa linear para a curva analítica de cloro e o limite de detecção foram, respectivamente: (0,2 - 3,0)x10-5 e 0,2 x10-5 mol L-1. / The chemiluminescent reactions of bis (2,4,6-trichlorophenyl) oxalate (TCPO) and bis(2-nitrophenyl) oxalate (2-NPO), with fluoranthene as fluorophore, in aqueous micellar systems, were studied in the presence of surfactants. The oxidation of these oxalates by hydrogen peroxide or t-butyl peroxide produces chemiluminescence, which depends on the acidity and imidazole presence. The chemiluminescent intensity is higher in the presence of some surfactants, especially CTAC, OTAC, DDAB, DODAC and &#946;-cyclodextrine. The reaction of TCPO with free chlorine (HCIO, CIO- and Cl2), in the presence of 9,10-diphenylanthracene as fluorophore in acetonitrile/water medium, was also investigated. A flow injection analysis system, for free chlorine determination with analytical application in tap water was developed. The linear range for free chlorine and detection limit were, respectively: (0.2-3.0)x10-5 and 0.2x10-5 mol L-1.
415

Microlaboratórios autônomos para monitoramento de parâmetros de qualidade da água. / Autonomous microlaboratories for water quality monitoring parameters.

Rocha, Zaira Mendes da 10 November 2009 (has links)
Neste trabalho, foram desenvolvidos MicroLaboratórios Autônomos (MLA), baseados no conceito de MicrosSistemas de Análise Total (TAS), que permitem a integração das etapas associadas ao método analítico em único dispositivo. Os MLA foram fabricados utilizando a tecnologia LTCC (Low Temperature Co-fired Ceramics), que permitiu um alto grau de integração das plataformas químicas microfluídica e eletrônica, utilizando o mesmo substrato. O MLA amperométrico foi construído de forma a integrar canais, misturadores e eletrodos (auxiliar, de referência e de trabalho (sendo o último facilmente removível, tornando o dispositivo mais versátil)). Também, possui integrado em sua superfície um potenciostato, capaz de aplicar potenciais constantes e registrar com precisão correntes na faixa de nA a A. Com o equipamento, foram realizadas medições de cianeto de ferro e cloro livre confirmando a funcionalidade do MLA amperométrico. Para tal, foram testadas concentrações de K4Fe(CN)6 variando de 0,1 3 mM, apresentando faixa linear de 0,1 a 0,75 mM com coeficiente de correlação linear de 0,997 e RSD de 1,91 % (calculado para a amostra de 0,75 mM, n = 13). Cloro livre foi medido na faixa de 0,35 7,10 mM apresentando resposta linear com r2 = 0,998, o RSD obtido foi de 1,93 % (3,5 mM; n = 15). O cloro livre foi medido em amostra reais de piscinas na faixa 0,4 a 1,1 mg L-1 e os resultados foram comparados com o método DPD (Ndietil- p-fenilenodiamina) apresentando resultados similares com r2 = 0,91. O MLA fotométrico segue o mesmo princípio do amperométrico com canais, misturadores, célula de fluxo, detector, arranjo de LEDs (420, 480, 515, 565, 590, 630 e 700 nm) e eletrônica de controle integrados no mesmo substrato. O equipamento foi desenvolvido permitindo dois modos de operação: espectrofotômetro e fotômetro. No modo espectrofotométrico foi empregado na determinação qualitativa e quantitativa de diversos corantes (alaranjado de metila, azul de metileno, verde de bromocressol e vermelho de fenol). Já na opção fotométrico foi usado na determinação de fósforo reativo em águas, por meio de um sistema completamente automatizado. Neste caso, o controle de diversas válvulas e uma bomba peristáltica permitiu a implementação de procedimentos de automatização como: multicomutação, amostragem binária e parada de fluxo (stopped flow. A utilização deste sistema automatizado permitiu a comparação entre dois métodos de preparações de amostra: diluição on-line (utilizando as válvulas) e preparadas manualmente. Para ambos os casos foram analisadas duas faixas de concentrações (0,1 a 1 mg L-1 e 1,5 a 15 mg L-1). A primeira faixa apresentou-se linear para ambos os métodos de preparação de amostra, apresentando limites de detecção para fósforo reativo de 15,8 g L-1 e 14,9 g L-1. Por outro lado, foi observado que a segunda faixa de concentração não obedece à lei de Beer. Na segunda faixa, a curva analítica foi linear no intervalo de concentração de 1,5 a 7,5 mg L-1 de fósforo reativo com r2 = 0,965 e RSD de 0,43 % (7,5 mg L-1, n = 3). A frequência de medições analíticas foi de 30 determinações por hora, o que indica que a plataforma proposta pode ser utilizada em monitoramente contínuo e de tempo real. / Analysis System (uTAS) concept which allows the integration of all steps related to an analytical process in a single device. The developed MLAs were used to monitor water quality. The MLAs were fabricated using the LTCC (Low Temperature Co-fired Ceramics) technology which allows a high integration level between chemical, microfluidics and electronics platforms on the same substrate. The amperometric MLA was build in order to integrate channels, mixers and electrodes (reference, auxiliary and work) being the last one easily removable making the device even more versatile. It also has, integrated on its surface, a potentiostate capable of applying constant voltages and precisely recording currents in the range from nA to A. With this equipment, measurements were conducted for free chlorine and iron, confirming the functionality of the amperometric MLA. Concentrations from 0,1 to 3 mM of K4Fe(CN)6 were evaluated obtaining a linear range from 0,1 to 0,75 mM with a linear correlation coefficient of 0,997 and a RSD of 1,91 % (calculated for the 0,75 mM sample with n = 13). Free chlorine was evaluated in the range from 0,35 to 7,10 mM obtaining a linear response with a r2 = 0,998, the obtained RSD was 1,93 % (for 3,5 mM; n = 15). Free chlorine was also evaluated in real samples from swimming pools in the range from 0,4 to 1,1 mg·L-1, comparing the results with those obtained by the colorimetric DPD method, showing similar values with a r2 = 0,91. The photometric MLA follows the same principle of the amperometric one, with channels, mixers, flow cell, detector, LEDs array (420, 480, 515, 565, 590, 630 e 700 nm) and control electronics, integrated in the same substrate. This equipment was developed for two operation modes: spectrophotometric and photometric. The spectrophotometric mode was used for qualitative and quantitative determination of different dyes (methyl orange, methylene blue, bromocressol green and phenol red). The photometric option was used for the determination of phosphate concentration in water, by means of a fully automated system. In this case the control of several valves and a peristaltic pump allowed the implementation or automated procedures like multicommutation, binary sampling and stopped flow. The use of this automated system allowed the comparison between two methods for sample preparation: online dilution (with valves) and manual preparation. In both cases two concentration ranges were evaluated (0,1 a 1 mg L-1 and 1,5 a 15 mg L-1). The first range linear for both sample preparation methods, with detection limits of 15,8 g L-1 e 14,9 g L-1 for orthophosphate. On the other side it was observed that in the second range of concentrations it does not obey the Beers law. In the second range, the analytics curve was linear in the interval from 1,5 to 7,5 mg L-1 of orthophosphate with a r2 = 0,965 and a RSD of 0,43 % (7,5 mg L-1, n = 3). The analytical frequency was about 30 determinations per hour, which indicates a good performance of the proposed device for on-line and real time monitoring.
416

Calibração de modelo de decaimento de cloro aplicado a setor de rede de distribuição de água / Calibration of the chlorine decay model applied to a prototype water supply distribution network sector

Moraes, Fausto de Assis 29 September 2008 (has links)
O crescente adensamento populacional em grandes centros urbanos vem propiciando crescentes demandas hídricas. Esse fato aliado às limitações das fontes para abastecimento, tanto do ponto de vista quantitativo como qualitativo, impõe que políticas de gerenciamento da água sofram transformações no futuro próximo. Nesse sentido, devem merecer atenção especial as técnicas de reuso, bem como o uso racional e otimizado da água em meio urbano. O presente trabalho enfoca um dos principais aspectos do gerenciamento da qualidade da água para abastecimento, que é a manutenção do residual de cloro no interior da rede conforme a Portaria 518/2004. Trata-se de um problema complexo, uma vez que o cloro decai, ao longo do tempo, e se mistura nos nós da rede, sofrendo mudanças de concentração. Visando à modelagem e simulação do comportamento do cloro residual como uma ferramenta eficiente de gerenciamento dos sistemas de distribuição de água, muitos estudos têm sido realizados e reportados pela literatura assumindo-se que os efeitos do decaimento são representados pelos coeficientes Kbulk e Kwall. O presente trabalho realiza a calibração hidráulica e de qualidade para um setor de distribuição de água real do município de São Carlos - SP - Brasil, considerando o vazamento. Para tanto, calibradores hidráulicos já testados por outros autores foram usados, e um calibrador de qualidade para resolução do problema inverso, que utilizam em conjunto o simulador EPANET 2.0 e os algoritmos genéticos (AGs) como ferramenta de otimização, foram desenvolvidos. Foi evidenciada a importância de se considerar o vazamento na calibração hidráulica e conseqüentemente na calibração de qualidade. Foi desenvolvida também uma metodologia para a calibração dos parâmetros dos AGs através do uso do \"Particle Swarm Optimization\" (PSO). Foram testados ainda diversos modelos de vazamento para determinação de qual modelo seria capaz de representar de maneira mais fidedigna o comportamento hidráulico da rede e os resultados obtidos apontaram os modelos que admitem vazamento por comprimento linear da tubulação como sendo mais adequados. / The rising population density of large urban centers is gradually increasing water supply demands. This together with the paucity of water sources requires that the future water administration policies go through a transformation from both quantitative and qualitative points of view. Thus rational use of available water and water reuse deserve special attention in the urban environment. This study focuses on one these main aspects of water quality management, namely, the maintenance of residual chlorine in the hydraulic network according the respective Directive nº 518/2004. This is a complex problem in view of the fact chlorine decays in time and undergoes mixing at the network nodes, consequently producing changes in its concentration. Numerous studies on modeling and simulation of behavior of residual chlorine, as an efficient water distribution system management tool, have been made and reported in literature. These studies assume that chlorine decay in the network can be represented through Kbulk and Kwall coefficients. This research work conducts hydraulic and water quality calibration of a prototype water distribution sector in the city of São Carlos - SP - Brazil, while taking into account leakages in the network. Hydraulic calibration programs previously tested by others and a water quality calibration program were employed for the solution of the inverse problem for determination of unknown parameters. This problem was solved using hydraulic simulator EPANET 2.0 in conjunction with the genetic algorithms (AGs). These procedures showed the importance of considering network leakages in hydraulic calibration and consequently in the calibration of water quality. A method for the calibration of AG parameters was also developed through the use of \"Particle Swarm Optimization\" (PSO). Various representations for leakage were tested in order to identify the model that best described the hydraulic performance of the network. Thus it was possible to show that the models, which consider leakage per unit length, were the most adequate.
417

Estudo dos parâmetros do decaimento do cloro residual em sistema de distribuição de água tratada considerando vazamento / Study of the residual decay parameters in water distribution systems with leakage

Salgado, Sérgio Ricardo Toledo 15 February 2008 (has links)
O uso do cloro como desinfetante em sistemas de água para abastecimento é prática comum nas estações de tratamento de água. Introduzido durante o processo de tratamento, o cloro participa de diversas reações com compostos de naturezas orgânicos e inorgânicos no interior das tubulações. Tais reações ocorrem na massa líquida e junto às paredes das tubulações e são responsáveis pelo decaimento do cloro ao longo das redes. Visualizando a modelagem como uma ferramenta eficiente para gerenciar o cloro residual em sistemas de distribuição de água, muitos estudos foram realizados e reportados pela literatura, assumindo que os efeitos de decaimento de cloro podem ser bem representados pelos coeficientes kb e kw. Entretanto, a determinação de valores para parâmetros em questão não é uma tarefa fácil, devido à complexidade dos sistemas enfocados em termos da diversidade de materiais das tubulações e mananciais (superficiais e subterrâneos). No Brasil, apesar de legislação recente estabelecer limites restritivos para o cloro na água potável (após desinfecção, a concentração de cloro deve observar a concentração mínima de 0,5 mg/L, sendo o mínimo nível aceito em sistemas de distribuição de 0,2 mg/L e o máximo de 2,0 mg/L), poucos estudos enfocam a avaliação dos parâmetros de decaimento. Esta pesquisa apresenta a aplicação de um modelo inverso elaborado para determinar a ordem para o modelo de decaimento do cloro e os valores globais e/ou locais para o kb e o kw. Sendo programado com o suporte do simulador de EPANET 2 (toolkit) e os algoritmos genéticos como ferramenta de otimização, implementado através da biblioteca de GAlib C++. Os estudos foram realizados em dois sistemas reais da distribuição da água em que foram considerados parâmetros globais e parâmetros específicos da qualidade. Para a investigação da determinação de parâmetros de decaimento de cloro em sistemas de distribuição com vazamento em função da pressão, foi adotada uma rede hipotética com três fontes de cloro. Esse sistema permitiu a calibração e a validação do modelo, assim como a avaliação da influência hidráulica na determinação dos resultados de qualidade de água. / The use of chlorine as disinfectant in water supply systems has been a common practice adopted by the water industry. Introduced during the treatment process, chlorine participates in several reactions with compounds of organic and inorganic nature inside the pipes. Such reactions that occur in the bulk and the wall of the pipes are responsible for chlorine decay along the networks. Visualizing the modeling as an efficient tool to manage the chlorine residual in water distribution systems, many studies have been conducted and reported by the literature, assuming that the chlorine decay effects can be well represented by the decay coefficients kb and kw. However, the determination of values for theses parameters is not an easy task, due to the complexity of the focused systems in terms of pipe materials and water supply sources diversity (surface water and groundwater). In Brazil, instead of recent legislation stating more strict limits for chlorine in drinking water (after disinfection, chlorine concentration has to observe the minimum concentration of 0.5 mg/L, being the minimum accepted level in the distribution system of 0.2 mg/L and the maximum of 2.0 mg/L), few studies focus on the evaluation of the decay parameters. This research reports the application of an inverse model built to determine the order for chlorine decay model and the global and/or local values for kb and kw. It is codified with the support of EPANET 2 (Toolkit) simulator and technology of genetic algorithms as optimization tool, which is implemented by using the GAlib C++ library. The studies were conducted on two real water distribution systems considering both global and specific quality parameters. A hypothetical network with three sources of chlorine was studied too, admitting leakage as pressure function. This system permitted both calibration and validation of the model as well as the evaluation of hydraulic calibration influence on the water quality results.
418

Microlaboratórios autônomos para monitoramento de parâmetros de qualidade da água. / Autonomous microlaboratories for water quality monitoring parameters.

Zaira Mendes da Rocha 10 November 2009 (has links)
Neste trabalho, foram desenvolvidos MicroLaboratórios Autônomos (MLA), baseados no conceito de MicrosSistemas de Análise Total (TAS), que permitem a integração das etapas associadas ao método analítico em único dispositivo. Os MLA foram fabricados utilizando a tecnologia LTCC (Low Temperature Co-fired Ceramics), que permitiu um alto grau de integração das plataformas químicas microfluídica e eletrônica, utilizando o mesmo substrato. O MLA amperométrico foi construído de forma a integrar canais, misturadores e eletrodos (auxiliar, de referência e de trabalho (sendo o último facilmente removível, tornando o dispositivo mais versátil)). Também, possui integrado em sua superfície um potenciostato, capaz de aplicar potenciais constantes e registrar com precisão correntes na faixa de nA a A. Com o equipamento, foram realizadas medições de cianeto de ferro e cloro livre confirmando a funcionalidade do MLA amperométrico. Para tal, foram testadas concentrações de K4Fe(CN)6 variando de 0,1 3 mM, apresentando faixa linear de 0,1 a 0,75 mM com coeficiente de correlação linear de 0,997 e RSD de 1,91 % (calculado para a amostra de 0,75 mM, n = 13). Cloro livre foi medido na faixa de 0,35 7,10 mM apresentando resposta linear com r2 = 0,998, o RSD obtido foi de 1,93 % (3,5 mM; n = 15). O cloro livre foi medido em amostra reais de piscinas na faixa 0,4 a 1,1 mg L-1 e os resultados foram comparados com o método DPD (Ndietil- p-fenilenodiamina) apresentando resultados similares com r2 = 0,91. O MLA fotométrico segue o mesmo princípio do amperométrico com canais, misturadores, célula de fluxo, detector, arranjo de LEDs (420, 480, 515, 565, 590, 630 e 700 nm) e eletrônica de controle integrados no mesmo substrato. O equipamento foi desenvolvido permitindo dois modos de operação: espectrofotômetro e fotômetro. No modo espectrofotométrico foi empregado na determinação qualitativa e quantitativa de diversos corantes (alaranjado de metila, azul de metileno, verde de bromocressol e vermelho de fenol). Já na opção fotométrico foi usado na determinação de fósforo reativo em águas, por meio de um sistema completamente automatizado. Neste caso, o controle de diversas válvulas e uma bomba peristáltica permitiu a implementação de procedimentos de automatização como: multicomutação, amostragem binária e parada de fluxo (stopped flow. A utilização deste sistema automatizado permitiu a comparação entre dois métodos de preparações de amostra: diluição on-line (utilizando as válvulas) e preparadas manualmente. Para ambos os casos foram analisadas duas faixas de concentrações (0,1 a 1 mg L-1 e 1,5 a 15 mg L-1). A primeira faixa apresentou-se linear para ambos os métodos de preparação de amostra, apresentando limites de detecção para fósforo reativo de 15,8 g L-1 e 14,9 g L-1. Por outro lado, foi observado que a segunda faixa de concentração não obedece à lei de Beer. Na segunda faixa, a curva analítica foi linear no intervalo de concentração de 1,5 a 7,5 mg L-1 de fósforo reativo com r2 = 0,965 e RSD de 0,43 % (7,5 mg L-1, n = 3). A frequência de medições analíticas foi de 30 determinações por hora, o que indica que a plataforma proposta pode ser utilizada em monitoramente contínuo e de tempo real. / Analysis System (uTAS) concept which allows the integration of all steps related to an analytical process in a single device. The developed MLAs were used to monitor water quality. The MLAs were fabricated using the LTCC (Low Temperature Co-fired Ceramics) technology which allows a high integration level between chemical, microfluidics and electronics platforms on the same substrate. The amperometric MLA was build in order to integrate channels, mixers and electrodes (reference, auxiliary and work) being the last one easily removable making the device even more versatile. It also has, integrated on its surface, a potentiostate capable of applying constant voltages and precisely recording currents in the range from nA to A. With this equipment, measurements were conducted for free chlorine and iron, confirming the functionality of the amperometric MLA. Concentrations from 0,1 to 3 mM of K4Fe(CN)6 were evaluated obtaining a linear range from 0,1 to 0,75 mM with a linear correlation coefficient of 0,997 and a RSD of 1,91 % (calculated for the 0,75 mM sample with n = 13). Free chlorine was evaluated in the range from 0,35 to 7,10 mM obtaining a linear response with a r2 = 0,998, the obtained RSD was 1,93 % (for 3,5 mM; n = 15). Free chlorine was also evaluated in real samples from swimming pools in the range from 0,4 to 1,1 mg·L-1, comparing the results with those obtained by the colorimetric DPD method, showing similar values with a r2 = 0,91. The photometric MLA follows the same principle of the amperometric one, with channels, mixers, flow cell, detector, LEDs array (420, 480, 515, 565, 590, 630 e 700 nm) and control electronics, integrated in the same substrate. This equipment was developed for two operation modes: spectrophotometric and photometric. The spectrophotometric mode was used for qualitative and quantitative determination of different dyes (methyl orange, methylene blue, bromocressol green and phenol red). The photometric option was used for the determination of phosphate concentration in water, by means of a fully automated system. In this case the control of several valves and a peristaltic pump allowed the implementation or automated procedures like multicommutation, binary sampling and stopped flow. The use of this automated system allowed the comparison between two methods for sample preparation: online dilution (with valves) and manual preparation. In both cases two concentration ranges were evaluated (0,1 a 1 mg L-1 and 1,5 a 15 mg L-1). The first range linear for both sample preparation methods, with detection limits of 15,8 g L-1 e 14,9 g L-1 for orthophosphate. On the other side it was observed that in the second range of concentrations it does not obey the Beers law. In the second range, the analytics curve was linear in the interval from 1,5 to 7,5 mg L-1 of orthophosphate with a r2 = 0,965 and a RSD of 0,43 % (7,5 mg L-1, n = 3). The analytical frequency was about 30 determinations per hour, which indicates a good performance of the proposed device for on-line and real time monitoring.
419

Estudo da utilização de filmes poliméricos a base de DNA como sistema carreador de fármacos e ativos / Study the use of DNA-based polymer films as a drug and active drug delivery system.

Jayme, Cristiano Ceron 08 March 2018 (has links)
Os filmes poliméricos a base de DNA (DNA-PFs) são um sistema de veiculação de fármacos extremamente promissor aplicado à medicina moderna além de convergir busca de alternativas mais seletivas para o tratamento de câncer de boca via Terapia Fotodinâmica. A Ftalocianina de alumínio-cloro (AlClPc) é um fotossensibilizador de segunda geração aplicado em terapia fotodinâmica (TFD) caracterizado por seu caráter anfifílico e tendência de autoagregação em meio aquoso, prejudicando diretamente seu potencial de aplicação. Objetivando a busca das melhores condições de incorporação da (AlClPc) ao (DNA) foram determinadas as melhores proporções dos componentes a serem estudadas em diferentes condições de solubilidade. Os (DNA-PFs) foram preparados via Casting e para esclarecer sua compatibilidade e aplicabilidade, foram avaliados os aspectos morfológicos, bioquímicos e adesão celular das células de carcinoma escamosas orais (OSCC) nos (DNA-PFs). Foi observada uma alteração inicial e temporária na morfologia das células, devido ao processo de ligação ao filme nos estágios iniciais, conforme esperado, que retorna então a um estado morfológico normal mais tarde na configuração. Os estudos de citometria de fluxo mostraram baixa citotoxicidade de (DNA-PFs) no sistema, apresentando viabilidade superior a 90% em todos os (DNA-PFs) testados. Corroboram com esses resultados as análises da cinética do ciclo celular, mostrando que a cinética das células OSCC é mantida na presença de (DNA-PFs). Esses resultados indicam uma alta biocompatibilidade dos (DNA-PFs) produzidos. Após a incorporação da (Al- ClPc) aos (DNA-PFs) efetuou-se o uso do novo do sistema de veiculação aplicado a (TFD). Ficando evidente o aumento da morte celular, nas respectivas doses aplicadas. Tento em vista a redução de viabilidade celular apresentada pelo tratamento dos (DNA-PFs-AlClPc) verificou- se ainda o tipo de morte celular induzida pelo tratamento indicando como via preferencial de morte celular ocasionado por apoptose Estes resultados servem como base e possibilitam a abertura de novas perspectiva do potencial uso dos (DNA-PFs) aplicados como sistema de veiculação de fármacos para o tratamento fotodinâmico. / DNA-based polymer films (DNA-PFs) are an active drug delivery system applied to modern medicine besides converging search for more selective alternatives for the treatment of oral cancer through Photodynamic Therapy (PDT). Aluminum chlorine phthalocyanine (AlClPc) is a second-generation photosensitizer applied in PDT characterized by amphiphilic and tendency for self-aggregation in the aqueous medium, directly damaging its application potential. Aiming the search for the best conditions of incorporation of AlClPc to DNA the best proportions of the components to be studied under different solubility conditions were determined. The DNA-PFs were prepared via Casting and to clarify their compatibility and applicability, the morphological, biochemical and cell adhesion aspects of oral squamous cell carcinoma (OSCC) were evaluated in DNA-PFs. An initial and temporary alteration in cell morphology was observed due to the process of binding to the film in the initial stages, as expected, which then returns to a normal morphological state later in the configuration. Flow cytometry studies showed low cytotoxicity of DNA-PFs in the system, presenting viability higher than 90% in all DNA-PFs tested. They corroborate with these results the analyzes of the cell cycle kinetics, showing that the kinetics of OSCC cells is maintained in the presence of DNA-PFs. These results demonstrate high biocompatibility of the DNA-PFs produced. After incorporation of AlClPc to the DNA-PFs, the new one of the delivery system applied to PDT was used. The increase in cell death was evident in the several doses applied. Given the reduction of cell viability presented by the treatment of DNA-PFs-AlClPc, the type of cell death induced by the treatment was also showing, as the preferential route of cell death caused by apoptosis. These results allow new opportunities for potential use DNA-PFs DNA applied as a drug delivery system for PDT.
420

Remoção de atividade estrogênica do hormônio 17&beta;-Estradiol em processos de oxidação de águas para abastecimento / Removal of estrogenic activity of the hormone 17&beta;-estradiol in oxidation processes for drinking water

Silva, Paulo Rogério Martins da 25 October 2013 (has links)
Muitos oxidantes químicos reativos acarretam na ruptura de estruturas moleculares complexas de vários tipos de compostos orgânicos decompondo-as em estruturas mais simples e propiciando condições melhores para uma efetiva ação de micro-organismos na degradação biológica. A presença de hormônios, entre eles o 17&beta;-estradiol, em estações de tratamento de esgoto e em águas subterrâneas e superficiais mostra a necessidade de uma avaliação dos processos de tratamento convencionais. O objetivo deste trabalho foi a análise e remoção de hormônios através de técnicas de cloração e ozonização de amostras reais de águas de saída de filtro de estações de tratamento de água (ETAs), operadas pelo Serviço Autônomo de Água e Esgoto (SAAE) de São Carlos (ETA Centro), que capta águas dos ribeirão Feijão e córrego Espraiado e pela Sociedade de Abastecimento de Água e Saneamento S/A (SANASA) de Campinas (ETAs 3 e 4), que capta águas do rio Atibaia. Foram realizados ensaios contaminando-se as amostras com 17&beta;-estradiol, que é o hormônio natural mais presente no meio ambiente, em concentração de 6.000 ng L-1, submetendo-se tratamento com dosagens em torno de 0,5 e 2,0 mg L-1 desses oxidantes, em tempos de contato de, respectivamente, 10 e 30 min. As amostras submetidas à contaminação e tratamento e as de controle (sem contaminação e tratamento) foram analisadas através da remoção do 17&beta;-estradiol com a verificação da atividade estrogênica das amostras por ensaios de Sistema de Expressão de Estrogênio Induzida por Levedura Bioluminescente (BLYES), que apresentou-se como uma ferramenta simples. Os resultados apresentados neste trabalho demonstram que a oxidação por ozônio se mostrou mais eficiente do que aquela por cloro para a remoção da atividade estrogênica causada, única e exclusivamente, pelo 17&beta;-estradiol para uma dosagem inicial desse hormônio relativamente alta (6.000 ng L-1). Todavia, em todos os ensaios a concentração final da atividade estrogênica permaneceu acima do limite de quantificação desses hormônio, indicando que a remoção não foi completa, mesmo em condições favoráveis, isto é, matriz limpa, com padrões de potabilidade para os parâmetros físico-químicos. / Many reactive chemical oxidants cause the disruption of the complex molecular structures of various types of organic compounds decomposing them into simpler structures and providing better conditions for effective action of micro-organisms in the biological degradation. The presence of hormones, including 17&beta;-estradiol in sewage treatment plants and groundwater and surface water shows the need for an evaluation of conventional treatment processes. The aim of this study was the analysis and removal of hormones through techniques of chlorination and ozonation of real samples of output filter water in water treatment plants (WTP), operated by the Serviço Autônomo de Água e Esgoto (SAAE) of São Carlos (Center WTP), which captures waters from Espraiado stream and Feijão stream and the Sociedade de Abastecimento de Água e Saneamento S/A (SANASA) de Campinas (WTPs 3 and 4), which captures water from the Atibaia river. Assays were performed contaminating the samples with 17&beta;-estradiol, which is the natural hormone more present in the environment, in a concentration of 6.000 ng L-1 submitting themselves to treatment with dosages of around 0.5 to 2.0 mg L-1 of these oxidants in times of contact, respectively, 10 and 30 min. The samples subjected to contamination and treatment and control samples (without contamination and treatment) were analyzed by removing 17&beta;-estradiol with estrogenic activity verification of the samples by Bioluminescent Assays or Estrogen-Inducible Yeast Expression System (BLYES), which was presented as a simple tool. The results presented here demonstrate that the oxidation by ozone was more effective than with chlorine to remove estrogenic activity caused solely by 17&beta;-estradiol for an initial dosage of the hormone relatively high (6000 ngL -1) However, in all experiments the final concentration of estrogenic activity remained above the limit of quantification of these hormones, indicating that removal was not complete, even under favorable conditions, clean matrix with quality for drinking water physico-chemical parameters.

Page generated in 0.0787 seconds