• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 16
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 30
  • 19
  • 17
  • 11
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Orçamento de obras : análise na composição do BDI (Bonificação e Despesas Indiretas) e sua influência na exequibilidade dos preços das obras públicas / Building construction budget: analysis od BDI (Bonus and Indirect Expenditures) composition and its feasibility of the price of public works

Cunha Júnior, Gilberto José Carneiro da 01 December 2007 (has links)
Made available in DSpace on 2017-06-01T17:57:23Z (GMT). No. of bitstreams: 1 pre-textuais.PDF: 10285130 bytes, checksum: aceb2505631243bd8b01af593e28c82d (MD5) Previous issue date: 2007-12-01 / Breve / O preço de uma obra é composto de custos diretos, custos indiretos e lucro. É justamente sobre essas despesas indiretas e a bonificação (BDI) que residem as maiores dúvidas e questionamentos em relação à conceituação, aplicação e estimação. O custo direto da construção é facilmente orçável. O problema está na estimativa e controle dos demais elementos formadores do preço, como despesas administrativas, financeiras e custos indiretos no canteiro de obras. Quanto mais o BDI refletir os custos indiretos reais, melhores as possibilidades de se ofertar preços exeqüíveis, competitivos e justos. O objetivo da pesquisa é verificar a influência do BDI (Bonificação e Despesas Indiretas) na exeqüibilidade dos preços das obras públicas, sabendo que este é um incremento percentual aplicado aos custos dos serviços de engenharia para formatação de seus preços. O trabalho procurou comparar os percentuais dos componentes do BDI de algumas obras licitadas pela Empresa de Urbanização do Recife URB, com os seus respectivos valores recomendados pela legislação aplicável e literatura especializada sobre o tema, a fim de levantar a hipótese de que os aditivos de preço contratuais observados nos dados da pesquisa, têm estreita relação com a imperfeita composição da taxa do BDI. Ao final da pesquisa verificou-se uma grande incompatibilidade entre os valores ofertados pelas empresas e os recomendados pela literatura. Essas imperfeições na composição do BDI, colaboraram para a concretização de aditivos para a conclusão das obras estudadas
62

Constrição celular apical durante a invaginação do placóide do cristalino em galinhas. / Apical cell constriction during chicken lens placode invagination.

Ricardo Moraes Borges 06 November 2008 (has links)
O cristalino de vertebrados se origina a partir da invaginação do ectoderme que recobre a vesícula óptica. A invaginação epitelial em diversos modelos é causada pela constrição celular apical, mediada pela contração apical de actina e miosina II e regulada pela GTPase RhoA. Neste trabalho nós investigamos se a invaginação do cristalino em embriões de galinha ocorre devido à constrição celular apical e se este evento é controlado por RhoA. Actina filamentosa e miosina II são expressas na porção apical do cristalino durante a invaginação. Quando a polimerização de actina é inibida por Citocalasina D, o cristalino não invagina, sugerindo que a constrição celular apical poderia contribuir para a invaginação do cristalino. RhoA também é expressa durante o desenvolvimento do cristalino, mas a inibição de RhoA, por eletroporação da forma dominante-negativo, não impediu a invaginação do placóide do cristalino, não alterou a distribuição de miosina II na porção apical do cristalino nem sua ativação, indicando que a invaginação do cristalino independe de RhoA. / Vertebrate lens derives from invagination of the ectoderm that overlies optic vesicles. Epithelial invagination in many model systems is driven by apical cell constriction, mediated by actin and myosin II contraction regulated by GTPase RhoA. Here we investigate the possibility that chick lens placode invagination could also be driven by apical cell constriction and controlled by RhoA. We show that actin and myosin II are expressed at lens apical side during lens invagination. Actin polymerization inhibition by in ovo Cytochalasin D treatment prevents lens placode invagination, suggesting that lens placode invagination could be driven by apical cell constriction. RhoA GTPase is also expressed at apical portion of lens placode and during lens invagination. However, when we overexpressed by electroporation the dominant-negative RhoA in the pre-lens ectoderm invagination was not affected. Furthermore, dominant-negative RhoA didnt affect myosin II apical localization nor myosin II phosphorilation, indicating that in lens invagination this process is not regulated by GTPase RhoA.
63

Fundamental study of contact resistance behavior in RSW aluminum

Sun, Ta-chien January 2003 (has links)
No description available.
64

Ultra-sonografia convencional e com Doppler colorido no diagnóstico de estenose da veia porta e da veia hepática em crianças submetidas a transplante hepático segmentar / Portal and Hepatic venous stenoses after pediatric segmental liver transplantation: the role of real time and Doppler ultrasound

Suzuki, Lisa 10 May 2006 (has links)
INTRODUÇÃO: Nos pacientes pediátricos, em razão das limitações relacionadas ao tamanho dos receptores, são utilizados segmentos do fígado provenientes de \"cadáver\" ou de doador vivo (\"fígado reduzido\"). As complicações decorrentes das anastomoses cirúrgicas podem ser de natureza vascular e biliar, sendo que a maior causa de perda do enxerto deve-se à trombose ou estenose da artéria hepática, veia porta e veias hepáticas. A ultra-sonografia convencional e com Doppler colorido (US-DC) pode ser utilizada para avaliação dessas complicações. Todavia, apesar da alta sensibilidade e especificidade deste método, há poucas descrições a respeito de parâmetros que podem ser utilizados para o estudo das alterações vasculares. OBJETIVO: Estabelecer parâmetros de ultra-sonografia convencional e com Doppler colorido (US-DC) para o diagnóstico de estenose da VP e VH no transplante hepático reduzido em crianças. MÉTODO: Estudo retrospectivo de 134 US-DC realizado em 48 crianças submetidas a transplante hepático segmentar no Instituto da Criança do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo (ICr-HC-FMUSP), entre janeiro de 2002 e julho de 2005. No estudo da VP, os seguintes parâmetros foram analisados: calibre da VP na anastomose; velocidade máxima na anastomose (VP1); velocidade máxima no segmento pré-anastomose (VP2) e relação entre as velocidades máximas na anastomose/préanastomose (VP1/VP2). No estudo da VH, foram analisados: velocidade máxima na anastomose (VH1); velocidade na VH (VH2) e relação entre as velocidades máximas na anastomose/VH (VH1/VH2). Pacientes com estenose confirmada pela angiografia foram incluídos no grupo estenose e pacientes com angiografia ou cirurgia normal ou com boa evolução clínica foram incluídos grupo controle. RESULTADOS: Quatorze US-DC tiveram estenose da VP confirmadas pela portografia. O calibre da VP na anastomose foi menor no grupo estenose do que no grupo controle (média 2,5mm e 6,3mm respectivamente); PV1 e PV1/PV2 foram maiores no grupo estenose do que no grupo controle (média PV1 = 172cm/s, PV1/PV2 = 5,1 / PV1 = 83cm/s, PV1/PV2 = 1,8 respectivamente). O calibre da VP < 3,3mm apresentou a melhor correlação com a portografia (sensibilidade = 93% e especificidade = 88%), seguidos de VP1 > 128cm/s (sensibilidade = 86% e especificidade = 84%) e VP1/VP2 > 2,4 (sensibilidade = 79% e especificidade = 86%). Doze US-DC tiveram estenose da VH confirmada pela angiografia. A VH1 e HV1/VH2 foram maiores no grupo estenose do que no grupo controle (média VH1 = 202.2cm/s, VH1/VH2 = 6,0 / VH1 = 136,8cm/s, VH1/VH2 = 3,0 respectivamente). A relação VH1/VH2 > 4 apresentou a melhor correlação com a angiografia (sensibilidade = 83% e especificidade = 84%) seguido de VH1 > 128cm/s (sensibilidade = 83% e especificidade = 52%). CONCLUSÃO: Calibre da VP < 3,3mm na anastomose e relação das velocidades VH1/VH2 > 4 são altamente sensíveis e específicos no diagnóstico das estenoses da anastomose da VP e VH respectivamente, no póstransplante hepático em crianças / INTRODUCTION: Cadáveric split liver and living donor liver transplantation is mostly performed in children because of a shortage of suitable hepatic allograft in this population. Real time and Doppler ultrasound (CD-US) is the initial imaging modality for detection and follow-up of early and delayed vascular and non-vascular complications after liver transplant, but there are only few studies concerning its value in the diagnosis of venous complications. OBJECTIVE: Determine real time and Doppler ultrasound (CD-US) diagnostic parameters of portal (PV) and hepatic vein (HV) stenoses after segmental liver transplantation in children and assess their sensitivity and specificity. METHOD: Retrospective study of 134 CD-US performed in 48 patients submitted to segmental liver transplantation at Child Institute of University of Sao Paulo Medical School from January 2002 through July 2005. PV parameters: diameter at the anastomosis, velocities at the anastomosis (PV1) and at the pre-anastomosis segments (PV2) and the ratio PV1/PV2. HV parameters: velocities at the HV anastomosis to the inferior vena cava (HV1), at HV (HV2) and the ratio HV1/HV2. Stenosis group: patients with stenosis confirmed by angiography. Control group: patients presenting normal angiography or uneventhfull surgery or good clinical outcome. RESULTS: Fourteen CD-US had PV stenosis confirmed by portography. Diameter of PV at the anastomosis: narrower in the stenosis group (2.5mm) than in the control group (6.3mm) (p<.5). Mean PV1 and PV1/PV2: higher in the stenosis group than in the control group (PV1 = 172 cm/s, PV1/PV2 = 5.1/PV1 = 83cm/s, PV1/PV2 = 1.8). Statistical analysis determined as predictive of PV stenosis: PV diameter < 3.3mm (sensitivity of 93% and specificity of 88.4%); PV1 > 128cm/s (sensitivity of 86% and specificity of 84%) and PV1/PV2 > 2.4 (sensitivity of 79% and specificity of 86%). Twelve CD-US had HV stenosis confirmed by angiography. Mean HV1 and HV1/HV2: higher in the study group (HV1 = 202.2cm/s, HV1/HV2 = 6.0 / HV1 = 136.8cm/s, HV1/HV2 = 3.0) (p<.05). Statistical analysis determined as predictive of HV stenosis: PV1 > 128cm/s (sensitivity of 83% and specificity of 52%) and HV1/HV2 > 4 (sensitivity of 83% and specificity of 84%). CONCLUSION: PV diameter < 3.3mm at the anastomosis and HV1/HV2 > 4.0 are highly predictive for detection of PV and HV stenosis respectively, after pediatric segmental liver transplantation
65

Avaliação de possíveis mecanismos envolvidos no efeito antinociceptivo do C-terminal da S100A9 murina sobre a dor neuropática experimental / Evaluation of possible mechanisms involved in the antinociceptive effect of the C-terminus of murine S100A9 on experimental neuropathic pain: an experimental approach

Paccola, Carina Cicconi 13 February 2008 (has links)
O peptídeo sintético idêntico ao C-terminal da proteína S100A9 murina (pS100A9m) possui efeito antinociceptivo em diferentes modelos de dor inflamatória aguda. No presente estudo, o efeito do pS100A9m foi avaliado sobre a dor neuropática induzida pela constrição crônica (CCI) do nervo ciático em ratos. Ainda, foram investigados os possíveis mecanismos envolvidos neste efeito. A nocicepção foi avaliada pelos testes de hiperalgesia, alodinia e dor espontânea. Os animais foram tratados com diferentes doses do pS100A9m pelas vias intraplantar, oral ou intratecal 14 dias após a CCI e a nocicepção avaliada após 1 hora. As três vias de administração bloquearam a hiperalgesia, a alodinia e a dor espontânea decorrentes da dor neuropática. A duração do efeito do pS100A9m varia de acordo com a via utilizada e com o fenômeno nociceptivo testado. Ainda, a injeção intraplantar do peptídeo, na pata contralateral à CCI, inibiu a hiperalgesia e a alodinia observadas após a constrição do nervo. Quando o pS100A9m foi administrado pela via intraplantar no 7° dia após a CCI, ele também induziu inibição da hiperalgesia inflamatória que é observada nesse período. Os prováveis mecanismos envolvidos no efeito antinociceptivo do pS100A9m foram investigados pela administração de antagonistas de receptores de serotonina, noradrenalina, GABA (A e B) e opióides. Os resultados obtidos demonstraram que apenas o antagonista de receptor GABAB reverteu completamente o efeito antinociceptivo do pS100A9m sobre a dor neuropática, detectada no 14º dia pós-cirúrgico. Além disso, foram avaliadas as expressões das proteínas Egr-1, Fos e TNF&alpha; na medula dos ratos submetidos à CCI e tratados com o peptídeo 7 ou 14 dias do procedimento cirúrgico. O aumento na expressão das proteínas Egr-1 e Fos foi evidenciado tanto no 7º como no 14º dia após a CCI, em animais que não receberam nenhum tratamento ou aqueles que foram tratados com o veículo do peptídeo. Por outro lado, o pS100A9m inibiu a expressão destas duas proteínas no lado ipsolateral à CCI no corno dorsal da medula espinhal dos animais. Com relação ao TNF&alpha;, apenas no 7º dia após a CCI foi detectado o aumento na expressão desta proteína. Ainda, foi neste período que o pS100A9m acarretou inibição da expressão do TNF&alpha; no corno ventral de animais submetidos ao procedimento cirúrgico. Estes resultados demonstram que o C-terminal da S100A9 murina inibe a dor neuropática experimental por uma ação dependente de receptores GABAB, sugerindo que este peptídeo possivelmente promova uma ativação dos mecanismos inibitórios espinhais, acarretando em redução da ativação de neurônios na medula. Desta forma, o pS100A9m demonstra um potencial terapêutico para o tratamento de dores persistentes. / The synthetic peptide identical to the C-terminus of murine S100A9 protein (mS100A9p) has antinociceptive effect on different acute inflammatory pain models. In this study, the effect of mS100A9p was evaluated on neuropathic pain induced by chronic constriction injury (CCI) of the sciatic nerve in rats, and the possible mechanisms involved in this effect were investigated. Hyperalgesia, allodynia, and spontaneous pain were assessed to evaluate nociception. Rats were treated with different doses of mS100A9p by intraplantar, oral, or intrathecal routes on day 14 after CCI, and nociception was evaluated 1 hour later. These three routes of administration blocked hyperalgesia, allodynia and spontaneous pain. The duration of mS100A9p effect depends on the route used and the phenomenon analyzed. Moreover, intraplantar injection of mS100A9p in the contralateral paw inhibited the hyperalgesia and allodynia induced by CCI. When mS100A9p was administered by intraplantar route on day 7 after CCI, it reversed the inflammatory hyperalgesia observed in this period. The mechanisms likely involved in the antinociceptive effect of mS100A9p were investigated by administration of antagonists of serotonin, norepinephrine, GABA (A and B) and opioid receptors. Only the GABAB receptor antagonist completely reversed the antinociceptive effect of mS100A9p on neuropathic pain on day 14 after CCI. Besides, the expression of Egr-1, Fos and TNF&alpha; proteins was evaluated in the spinal cord of rats submitted to CCI and treated with mS100A9p on days 7 or 14 after CCI. The expression of Egr-1 and Fos was increased in animals not treated or treated with vehicle on days 7 and 14 after CCI. On the other hand, mS100A9p inhibited the expression of these two proteins in the dorsal horn of spinal cord ipsilateral to CCI. The increase in TNF&alpha; expression was observed exclusively on day 7 after CCI. In the same time period, mS100A9p nhibited the expression of TNF&alpha; in the ventral horn of spinal cord of animals submitted to CCI. The results obtained herein demonstrate that the C-terminus of murine S100A9 protein inhibits the experimental neuropathic pain by a GABAB-dependent action, suggesting that this peptide promotes the activation of spinal inhibitory mechanisms leading to the reduction of activation of spinal neurons. Therefore, mS100A9p demonstrates a potential therapeutic use in persistent pain syndromes.
66

Avaliação de endoprótese nacional em traquéia de coelhos. / Auto-expansible endoprosthesis. Biocompatibility in rabbits trachea.

Faria, Celso Murilo Nálio Matias de 22 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:38Z (GMT). No. of bitstreams: 1 celsomurilonmdefaria_dissert.pdf: 1426679 bytes, checksum: 62fc4b90d691c716aef67c9e6590368e (MD5) Previous issue date: 2011-11-22 / Introduction: the utilization of endoprosthesis has its main indication in the neoplasic obstructions do not surgically treatable. The foreign industry dependence is one of the barriers we found for the broad utilization of such devices. The relevance of this research is the development of a national prosthesis from easy access and low cost. Objective: to assess the biocompatibility of nitinol endoprosthesis with polyurethane in the rabbits trachea. Material and Method: Seventeen rabbits were studied from the New Zealand breed (Oryctolagus Sylvilagus), eight male and five female, with an average weight of 3255g (from 2570 to 4270g). The endoprosthesis were applied orally through laringoscopy, under general anesthesia and released in the middle third of the trachea. Radiological study was made to assure the placement of the endoprosthesis that allowed to compare the index of migration of the endoprosthesis in millimeters. The proposed time segment was 30 days. The microscopic variables study was proceeded: dilatation, incorporation and granolomatous tissue and histological cuts from the tracheal and lungs segments for microscopic study. The histological study measured the inflammatory process, the parietal alterations and the kind of epithelium observed in the tracheal bed. Results: Thirteen animals were included in the final study. The average segment time was 26 days (15 to 35 days in observation). Six animals underwent a radiological study during euthanasia and it was demonstrated displacement with migration of the prosthesis for the distal trachea in five animals. There was absence in one. It was shown the prosthesis had a complete expansion in seven animals and partial expansion in six. The incorporation of prosthesis in the tracheal lumen was observed in two animals and adhered in eleven. Granulomatous tissue was present in ten animals and absent in three. The histological study of the mucosa and submucosa showed inflammatory process predominantly of Polymorphonuclear cells as in the contact region with the prosthesis as in the proximal. The depth of the inflammatory process in the tracheal wall was larger in the tracheal area in contact with the prosthesis. The alterations of the respiratory epithelium: the metaplasia parameter was the most frequent in the area without contact with the prosthesis. Corrosion and ulceration were predominant in the area in contact with the prosthesis. The metaplasia parameter was the most frequent in the area in contact with the prosthesis. Conclusion: the nitinol endoprosthesis auto-expandable covered with polyurethane, produced by Braile Biomédica and implanted in the trachea of rabbits was easy to apply and liberation in the tracheal lumen. The endoprosthesis recovered with polyurethane showed in radiographic assessment distal migration, good radial expandability and formation of granuloma tissue. It was also observed an inflammatory process predominantly acute and restricted to the superficial portions of the trachea. The most frequent epithelium alterations in contact with the prosthesis were ulceration and regenerative hyperplasia. / Introdução: a utilização de endoprótese tem a principal indicação nas obstruções neoplásicas e nas obstruções não tratáveis cirurgicamente. A dependência da indústria estrangeira é uma das barreiras para utilização ampla destes dispositivos. A relevância deste trabalho é o desenvolvimento de uma prótese nacional de fácil acesso e baixo custo. Objetivo: avaliar endoprótese de nitinol revestida com poliuretano, na traqueia de coelhos. Material e Método: foram estudados 17 coelhos, da raça Nova Zelândia (Oryctolagus Cuniculus). Oito machos e nove fêmeas, com peso médio de 3522g (de 2570 a 4270g). As endopróteses foram aplicadas via oral, por meio de laringoscopia, sob anestesia geral, e liberadas no terço médio das traqueias. Realizou-se estudo radiológico para assegurar a posição da endoprótese que permitiu comparar o índice de migração da endoprótese em milímetros. O tempo proposto de seguimento foi de 30 dias. Procedeu-se ao estudo das variáveis macroscópicas: dilatação, incorporação e tecido de granulação e cortes histológicos dos segmentos traqueais e pulmonares para estudo microscópico. O estudo histológico mensurou o processo inflamatório, as alterações parietais e o tipo de epitélio observado no leito traqueal. Resultados: 13 animais foram incluídos no estudo definitivo. O tempo médio de seguimento foi 26 (15 a 35) dias em observação. Em seis animais submetidos a estudo radiológico por ocasião da eutanásia, demonstrou-se deslocamento com migração da prótese para traqueia distal, em cinco; ausência de migração em um. Demonstrou-se que a prótese tinha expansão completa em sete animais e parcial em seis. A incorporação da prótese na luz traqueal foi observada em dois animais, e aderido em 11. Tecido de granulação esteve presente em dez animais e ausente em três. O estudo histológico da mucosa e submucosa demonstrou processo inflamatório com predomínio de polimorfonucleares tanto na região em contato com a prótese quanto na proximal. A profundidade do processo inflamatório na parede traqueal foi maior na área traqueal em contato com a prótese. Das alterações do eptélio respiratório, o parâmetro metaplasia foi o mais frequente na área sem contato com a prótese. Corrosão e ulceração predominaram na área em contato com a prótese. Conclusões: A escolha do coelho no desenho do presente estudo prejudicou o resultado. Trata-se de estudo pioneiro tanto na utilização de coelho para estudo de endoprótese, quanto no desenvolvimento de endoprótese metálica autoexpansível nacional. As dificuldades foram naturais deste pioneirismo, mas prejudicaram o resultado final. A endoprótese autoexpansível de nitinol recoberta de poliuretano, produzida pela Braile Biomédica Ltda, (Brasil) e implantada na traqueia de coelhos, demonstrou-se de fácil aplicação e liberação na luz traqueal. Apresentou elevada taxa de migração, boa expansibilidade radial. Verificou-se alta frequência na formação de tecido de granulação e baixa permeabilidade. Observou-se ainda processo inflamatório predominantemente agudo e restrito ás porções superficiais da traquéia. As alterações epiteliais mais freqüentes em contato com a prótese foram ulceração e hiperplasia regenerativa.
67

Avaliação de possíveis mecanismos envolvidos no efeito antinociceptivo do C-terminal da S100A9 murina sobre a dor neuropática experimental / Evaluation of possible mechanisms involved in the antinociceptive effect of the C-terminus of murine S100A9 on experimental neuropathic pain: an experimental approach

Carina Cicconi Paccola 13 February 2008 (has links)
O peptídeo sintético idêntico ao C-terminal da proteína S100A9 murina (pS100A9m) possui efeito antinociceptivo em diferentes modelos de dor inflamatória aguda. No presente estudo, o efeito do pS100A9m foi avaliado sobre a dor neuropática induzida pela constrição crônica (CCI) do nervo ciático em ratos. Ainda, foram investigados os possíveis mecanismos envolvidos neste efeito. A nocicepção foi avaliada pelos testes de hiperalgesia, alodinia e dor espontânea. Os animais foram tratados com diferentes doses do pS100A9m pelas vias intraplantar, oral ou intratecal 14 dias após a CCI e a nocicepção avaliada após 1 hora. As três vias de administração bloquearam a hiperalgesia, a alodinia e a dor espontânea decorrentes da dor neuropática. A duração do efeito do pS100A9m varia de acordo com a via utilizada e com o fenômeno nociceptivo testado. Ainda, a injeção intraplantar do peptídeo, na pata contralateral à CCI, inibiu a hiperalgesia e a alodinia observadas após a constrição do nervo. Quando o pS100A9m foi administrado pela via intraplantar no 7° dia após a CCI, ele também induziu inibição da hiperalgesia inflamatória que é observada nesse período. Os prováveis mecanismos envolvidos no efeito antinociceptivo do pS100A9m foram investigados pela administração de antagonistas de receptores de serotonina, noradrenalina, GABA (A e B) e opióides. Os resultados obtidos demonstraram que apenas o antagonista de receptor GABAB reverteu completamente o efeito antinociceptivo do pS100A9m sobre a dor neuropática, detectada no 14º dia pós-cirúrgico. Além disso, foram avaliadas as expressões das proteínas Egr-1, Fos e TNF&alpha; na medula dos ratos submetidos à CCI e tratados com o peptídeo 7 ou 14 dias do procedimento cirúrgico. O aumento na expressão das proteínas Egr-1 e Fos foi evidenciado tanto no 7º como no 14º dia após a CCI, em animais que não receberam nenhum tratamento ou aqueles que foram tratados com o veículo do peptídeo. Por outro lado, o pS100A9m inibiu a expressão destas duas proteínas no lado ipsolateral à CCI no corno dorsal da medula espinhal dos animais. Com relação ao TNF&alpha;, apenas no 7º dia após a CCI foi detectado o aumento na expressão desta proteína. Ainda, foi neste período que o pS100A9m acarretou inibição da expressão do TNF&alpha; no corno ventral de animais submetidos ao procedimento cirúrgico. Estes resultados demonstram que o C-terminal da S100A9 murina inibe a dor neuropática experimental por uma ação dependente de receptores GABAB, sugerindo que este peptídeo possivelmente promova uma ativação dos mecanismos inibitórios espinhais, acarretando em redução da ativação de neurônios na medula. Desta forma, o pS100A9m demonstra um potencial terapêutico para o tratamento de dores persistentes. / The synthetic peptide identical to the C-terminus of murine S100A9 protein (mS100A9p) has antinociceptive effect on different acute inflammatory pain models. In this study, the effect of mS100A9p was evaluated on neuropathic pain induced by chronic constriction injury (CCI) of the sciatic nerve in rats, and the possible mechanisms involved in this effect were investigated. Hyperalgesia, allodynia, and spontaneous pain were assessed to evaluate nociception. Rats were treated with different doses of mS100A9p by intraplantar, oral, or intrathecal routes on day 14 after CCI, and nociception was evaluated 1 hour later. These three routes of administration blocked hyperalgesia, allodynia and spontaneous pain. The duration of mS100A9p effect depends on the route used and the phenomenon analyzed. Moreover, intraplantar injection of mS100A9p in the contralateral paw inhibited the hyperalgesia and allodynia induced by CCI. When mS100A9p was administered by intraplantar route on day 7 after CCI, it reversed the inflammatory hyperalgesia observed in this period. The mechanisms likely involved in the antinociceptive effect of mS100A9p were investigated by administration of antagonists of serotonin, norepinephrine, GABA (A and B) and opioid receptors. Only the GABAB receptor antagonist completely reversed the antinociceptive effect of mS100A9p on neuropathic pain on day 14 after CCI. Besides, the expression of Egr-1, Fos and TNF&alpha; proteins was evaluated in the spinal cord of rats submitted to CCI and treated with mS100A9p on days 7 or 14 after CCI. The expression of Egr-1 and Fos was increased in animals not treated or treated with vehicle on days 7 and 14 after CCI. On the other hand, mS100A9p inhibited the expression of these two proteins in the dorsal horn of spinal cord ipsilateral to CCI. The increase in TNF&alpha; expression was observed exclusively on day 7 after CCI. In the same time period, mS100A9p nhibited the expression of TNF&alpha; in the ventral horn of spinal cord of animals submitted to CCI. The results obtained herein demonstrate that the C-terminus of murine S100A9 protein inhibits the experimental neuropathic pain by a GABAB-dependent action, suggesting that this peptide promotes the activation of spinal inhibitory mechanisms leading to the reduction of activation of spinal neurons. Therefore, mS100A9p demonstrates a potential therapeutic use in persistent pain syndromes.
68

Ultra-sonografia convencional e com Doppler colorido no diagnóstico de estenose da veia porta e da veia hepática em crianças submetidas a transplante hepático segmentar / Portal and Hepatic venous stenoses after pediatric segmental liver transplantation: the role of real time and Doppler ultrasound

Lisa Suzuki 10 May 2006 (has links)
INTRODUÇÃO: Nos pacientes pediátricos, em razão das limitações relacionadas ao tamanho dos receptores, são utilizados segmentos do fígado provenientes de \"cadáver\" ou de doador vivo (\"fígado reduzido\"). As complicações decorrentes das anastomoses cirúrgicas podem ser de natureza vascular e biliar, sendo que a maior causa de perda do enxerto deve-se à trombose ou estenose da artéria hepática, veia porta e veias hepáticas. A ultra-sonografia convencional e com Doppler colorido (US-DC) pode ser utilizada para avaliação dessas complicações. Todavia, apesar da alta sensibilidade e especificidade deste método, há poucas descrições a respeito de parâmetros que podem ser utilizados para o estudo das alterações vasculares. OBJETIVO: Estabelecer parâmetros de ultra-sonografia convencional e com Doppler colorido (US-DC) para o diagnóstico de estenose da VP e VH no transplante hepático reduzido em crianças. MÉTODO: Estudo retrospectivo de 134 US-DC realizado em 48 crianças submetidas a transplante hepático segmentar no Instituto da Criança do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo (ICr-HC-FMUSP), entre janeiro de 2002 e julho de 2005. No estudo da VP, os seguintes parâmetros foram analisados: calibre da VP na anastomose; velocidade máxima na anastomose (VP1); velocidade máxima no segmento pré-anastomose (VP2) e relação entre as velocidades máximas na anastomose/préanastomose (VP1/VP2). No estudo da VH, foram analisados: velocidade máxima na anastomose (VH1); velocidade na VH (VH2) e relação entre as velocidades máximas na anastomose/VH (VH1/VH2). Pacientes com estenose confirmada pela angiografia foram incluídos no grupo estenose e pacientes com angiografia ou cirurgia normal ou com boa evolução clínica foram incluídos grupo controle. RESULTADOS: Quatorze US-DC tiveram estenose da VP confirmadas pela portografia. O calibre da VP na anastomose foi menor no grupo estenose do que no grupo controle (média 2,5mm e 6,3mm respectivamente); PV1 e PV1/PV2 foram maiores no grupo estenose do que no grupo controle (média PV1 = 172cm/s, PV1/PV2 = 5,1 / PV1 = 83cm/s, PV1/PV2 = 1,8 respectivamente). O calibre da VP < 3,3mm apresentou a melhor correlação com a portografia (sensibilidade = 93% e especificidade = 88%), seguidos de VP1 > 128cm/s (sensibilidade = 86% e especificidade = 84%) e VP1/VP2 > 2,4 (sensibilidade = 79% e especificidade = 86%). Doze US-DC tiveram estenose da VH confirmada pela angiografia. A VH1 e HV1/VH2 foram maiores no grupo estenose do que no grupo controle (média VH1 = 202.2cm/s, VH1/VH2 = 6,0 / VH1 = 136,8cm/s, VH1/VH2 = 3,0 respectivamente). A relação VH1/VH2 > 4 apresentou a melhor correlação com a angiografia (sensibilidade = 83% e especificidade = 84%) seguido de VH1 > 128cm/s (sensibilidade = 83% e especificidade = 52%). CONCLUSÃO: Calibre da VP < 3,3mm na anastomose e relação das velocidades VH1/VH2 > 4 são altamente sensíveis e específicos no diagnóstico das estenoses da anastomose da VP e VH respectivamente, no póstransplante hepático em crianças / INTRODUCTION: Cadáveric split liver and living donor liver transplantation is mostly performed in children because of a shortage of suitable hepatic allograft in this population. Real time and Doppler ultrasound (CD-US) is the initial imaging modality for detection and follow-up of early and delayed vascular and non-vascular complications after liver transplant, but there are only few studies concerning its value in the diagnosis of venous complications. OBJECTIVE: Determine real time and Doppler ultrasound (CD-US) diagnostic parameters of portal (PV) and hepatic vein (HV) stenoses after segmental liver transplantation in children and assess their sensitivity and specificity. METHOD: Retrospective study of 134 CD-US performed in 48 patients submitted to segmental liver transplantation at Child Institute of University of Sao Paulo Medical School from January 2002 through July 2005. PV parameters: diameter at the anastomosis, velocities at the anastomosis (PV1) and at the pre-anastomosis segments (PV2) and the ratio PV1/PV2. HV parameters: velocities at the HV anastomosis to the inferior vena cava (HV1), at HV (HV2) and the ratio HV1/HV2. Stenosis group: patients with stenosis confirmed by angiography. Control group: patients presenting normal angiography or uneventhfull surgery or good clinical outcome. RESULTS: Fourteen CD-US had PV stenosis confirmed by portography. Diameter of PV at the anastomosis: narrower in the stenosis group (2.5mm) than in the control group (6.3mm) (p<.5). Mean PV1 and PV1/PV2: higher in the stenosis group than in the control group (PV1 = 172 cm/s, PV1/PV2 = 5.1/PV1 = 83cm/s, PV1/PV2 = 1.8). Statistical analysis determined as predictive of PV stenosis: PV diameter < 3.3mm (sensitivity of 93% and specificity of 88.4%); PV1 > 128cm/s (sensitivity of 86% and specificity of 84%) and PV1/PV2 > 2.4 (sensitivity of 79% and specificity of 86%). Twelve CD-US had HV stenosis confirmed by angiography. Mean HV1 and HV1/HV2: higher in the study group (HV1 = 202.2cm/s, HV1/HV2 = 6.0 / HV1 = 136.8cm/s, HV1/HV2 = 3.0) (p<.05). Statistical analysis determined as predictive of HV stenosis: PV1 > 128cm/s (sensitivity of 83% and specificity of 52%) and HV1/HV2 > 4 (sensitivity of 83% and specificity of 84%). CONCLUSION: PV diameter < 3.3mm at the anastomosis and HV1/HV2 > 4.0 are highly predictive for detection of PV and HV stenosis respectively, after pediatric segmental liver transplantation
69

Einfluss des lymphatischen Systems auf die Entwicklung einer Herzinsuffizienz durch Erhöhung der Nachlast / Effect of lymphoid cells on the progression of pressure overload-induced heart failure

Sasse, André 06 December 2017 (has links)
No description available.
70

Nano-mélangeurs bolométriques supraconducteurs à électrons chauds en Y-Ba-Cu-O pour récepteur térahertz en mode passif / Superconducting Y-Ba-Cu-O hot electron bolometric nano-mixers for terahertz passive receivers

Ladret, Romain 06 July 2016 (has links)
Nous étudions un mélangeur d'ondes térahertz (THz) réalisé avec le supraconducteur à haute température critique YBaCuO en couches ultraminces (10 à 50 nm). Le travail vise à concevoir un démonstrateur portable pour la détection hétérodyne térahertz passive, avec une cryogénie simplifiée à 60-80 kelvin (projet ANR MASTHER).Le principe de détection est le bolomètre à électrons chauds (HEB) jusqu'à présent développé avec des supraconducteurs à basse température critique. L'effet HEB est mis en ¿uvre dans une constriction en YBaCuO (quelques centaines de nm de dimensions latérales). Cette structure conduit à un détecteur THz sensible et rapide (bande passante instantanée de 100 GHz). Le rayonnement THz est couplé à la constriction par une antenne planaire large bande.En premier lieu, les échanges thermiques entre réservoirs d'électrons et de phonons (YBaCuO et son substrat) sont modélisés. Nous établissons ainsi les conditions optimales pour le HEB en termes de dimensions de la constriction et de puissance de l'oscillateur local requises pour un mélange performant (gain et bruit). Par rapport aux modèles antérieurs, nous introduisons une approche de "point chaud" nouvelle incluant l'influence de la fréquence THz dans YBaCuO, ainsi que l'adaptation d'impédance entre la constriction et l'antenne. En second lieu, nous décrivons l'optimisation des étapes de micro-fabrication des HEB, en particulier les lithographies électronique et optique, pour obtenir des constrictions de 300 nm de côté. De premiers dispositifs ont été testés en détection directe infrarouge. Les performances entre des couches d'YBaCuO ultraminces préparées suivant différentes techniques sont comparées. / We report on the development of a terahertz (THz) wave mixer made from high critical temperature superconducting YBaCuO ultrathin films (10 to 50 nm). The work is part of the MASTHER ANR project aiming at a portable demonstrator for passive terahertz heterodyne detection, implementing simplified cryogenics (60 to 80 kelvin). The detection principle is that of the hot electron bolometer (HEB) so far mainly developed with low critical temperature superconductors. The HEB effect is implemented in an YBaCuO constriction (a few hundred nm in lateral dimensions). This structure can lead to a sensitive and fast THz detector (theoretical instantaneous bandwidth of 100 GHz). The THz radiation is coupled to the YBaCuO constriction by means of a wideband planar antenna. The new aspects first concern the modeling of heat exchange between electrons and phonons reservoirs (YBaCuO and its substrate). Our results establish the optimum operating conditions in terms of dimensions of the constriction and the local oscillator power required for high performance THz mixing (conversion gain and noise temperature). We are introducing in particular a new "hot spot" modeling approach, which takes into account the influence of the terahertz frequency in the YBaCuO material and the impedance matching between the antenna and the constriction. Second, we have developed and optimized the HEB micro-fabrication process in clean room, especially the electronic and optical lithography steps, to obtain constrictions of 300 nm lateral size. Our first devices have been tested by direct detection in the infrared. The performance between YBaCuO ultrathin films prepared using various techniques are compared.

Page generated in 0.1138 seconds