• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 54
  • Tagged with
  • 56
  • 56
  • 33
  • 32
  • 25
  • 19
  • 11
  • 10
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação de atenuadores de ruido passivos resistivos para grupos geradores de energia / Evaluation of passive resistive silencers of noise for energy generators

Araujo, Nilza Maria Coradi de 12 August 2018 (has links)
Orientador: Stelamaris Rolla Bertoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-12T06:49:31Z (GMT). No. of bitstreams: 1 Araujo_NilzaMariaCoradide_M.pdf: 13106007 bytes, checksum: 70f9cecd051bb62ae31e9b41e050b150 (MD5) Previous issue date: 2004 / Resumo: Esse trabalho tem por objetivo avaliar o desempenho acústico de atenuadores de ruído para grupos geradores de energia. Geradores de energia a diesel são equipamentos extremamente ruidosos e para tratar acusticamente um gerador é necessário, entre outras coisas, o tratamento das aberturas para ventilação. Essas aberturas são geralmente tratadas com atenuadores (silenciadores) de ruído .Existem vários tipos de silenciadores os mais comuns são os passivos resistivos que se caracterizam pelo uso de material absorvente nas paredes internas do duto. Os silenciadores objeto de estudo deste trabalho foram os dutos retangulares com células divisórias paralelas. Para a realização das medidas de desempenho acústico dos silenciadores foi utilizada a metodologia descrita na ISO 11 820 Acoustics - Measurements on Silencers in situo Essa norma apresenta dois parâmetros de avaliação de desempenho acústico: perda por transmissão e perda por inserção. Para realização da avaliação de desempenho acústico, foram construídos e testados 22 tipos diferentes de silenciadores, alterando as dimensões das lamelas, o tamanho do duto e a densidade e espessura do material absorvente. Os resultados das avaliações mostraram que a espessura das lamelas e o comprimento do duto têm uma maior influência na eficiência do atenuador do que a densidade do material absorvente. Realizou-se, ainda, uma análise comparativa entre eficiência e custo entre os silenciadores avaliados. Os resultados dessa analise permitiram estabelecer quais silenciadores que apresentaram a melhor relação custo benefício, isto é, melhor desempenho acústico e menor custo. / Abstract: The objective this work is to evaluate the acoustic performance of the silencers of noise for energy group generators. Generators of energy to Diesel are extremely noisy equipments. For acoustic treatment of a generator it is necessary, among other things, the treatment of the openings of ventilation. The openings are generally treated with silencers of noise. There are several types of silencers, the most common are the passive resistive. The passive resistive silencers are characterized by the use of absorbent material in the internal walls of the lined ducts. The silencer object of the study this work is the rectangular lined duct of the parallel bafflers. For the accomplishment of the measures of acoustic performance of the silencers was used the methodology described in ISO 11 820 Acoustics Measurements on Silencers in situ. The ISO 11 820 standard presents two parameters of evaluation of acoustic performance: transmission loss and insertion loss. For accomplishment of the evaluation of acoustic performance, were built and tested 22 types of different silencers, altering the dimensions of the bafflers the size of the duct and the density and thickness of the absorbent material. The results of the evaluations showed that the thickness of the bafflers and the length of the duct have a larger influence in the efficiency of the silencer than the density of the absorbent material. It was also made a comparative analysis between the efficiency and the cost among the appraised silencer. The results of that analyze allowed to establish which silencer that presented the best cost/benefit relation or the better acoustic performance and lower cost. / Mestrado / Edificações / Mestre em Engenharia Civil
32

Modelo em escala reduzida ao ar livre como ferramenta de validação de simulação computacional de barreiras acústicas / Scale outdoor models as validation tool for computer simulation of noise barriers

Lisot, Aline, 1980- 08 September 2013 (has links)
Orientador: Stelamaris Rolla Bertoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-23T15:55:45Z (GMT). No. of bitstreams: 1 Lisot_Aline_D.pdf: 22929481 bytes, checksum: b4a8e502fe551c84db705e90815efafe (MD5) Previous issue date: 2013 / Resumo: As barreiras acústicas têm sido empregadas como soluções de mitigação de ruído ambiental. O estudo sobre desempenho de barreiras acústicas é comumente realizado por meio de simulações computacionais em programas específicos de propagação sonora. Testes de modelos em escala reduzida efetuados em câmara anecóica também são ferramentas empregadas neste tipo de avaliação e podem auxiliar na validação do modelo computacional elaborado. A restrição de acesso a câmaras anecóicas e as grandes dimensões de algumas fontes sonoras, como é o caso de subestações elétricas, podem impossibilitar a realização de ensaios em tais câmaras e conduzir aos testes de modelos reduzidos ao ar livre. Estes testes são praticamente inexistentes na literatura, o que confere caráter original à pesquisa apresentada neste trabalho. No caso de subestações elétricas que porventura sejam causadoras de perturbação sonora no seu entorno, assinala-se a impossibilidade de implementação de soluções mitigadoras para posterior validação da solução empregada. Tal restrição ocorre devido, principalmente, à complexidade e às dimensões da fonte. Em casos como o mencionado, é indispensável um estudo prévio da solução mitigadora, o que pode ser feito por meio de simulações computacionais validadas através de modelos em escala reduzida. O presente trabalho tem por objetivo a verificação da viabilidade de utilização de modelos em escala reduzida ao ar livre como ferramenta de validação de simulação computacional de barreiras acústicas. De caráter experimental e cunho exploratório, o trabalho buscou validar modelo de barreira acústica em escala reduzida ao ar livre para teste de propagação sonora em subestação elétrica. A metodologia envolveu a caracterização da fonte sonora em questão, a construção e teste de modelo e a modelagem/simulação computacional da situação reproduzida em escala reduzida com o programa SoundPLAN 6.4®. Os resultados dos testes em escala reduzida foram empregados para validação de simulação computacional de barreira acústica. Concluiu-se que é possível utilizar modelos reduzidos para tal fim, porém, é necessário que se avalie as condições do entorno durante os ensaios. Dentre as características do entorno a serem avaliadas, citam-se as variáveis climáticas no momento da medição, o ruído de fundo do local, a topografia, o tipo de solo e a presença de vegetação e de edificações. Tais informações podem auxiliar na obtenção de resultados fidedignos e, desta forma, garantir o futuro desempenho de soluções mitigadoras de ruído por meio da utilização de modelos em escala reduzida para validação de simulação computacional / Abstract: Noise barriers have been used as solutions to mitigate environmental noise. The study on performance of noise barriers is commonly accomplished through computer simulations with the specific sound propagation software. Tests of reduced scale models made in anechoic chamber are also tools used in this type of evaluation and can assist in validating the developed computer model. The restriction of access to anechoic chambers and the large dimensions of certain sources, such as electrical substations, may not allow tests in these chambers and lead to reduced model tests outdoors. These tests are practically nonexistent in the literature, which gives unique character to the research presented in this work. In the case of electrical substations that may be causing noise disturbance in their surroundings, it is pointed out the impossibility of implementing mitigation solutions to post-validate the solution employed. This restriction is due mainly to the complexity and size of the source. In similar cases, it is necessary a previous study on mitigation solutions, which may be done by way of computer simulations validated through reduced scale models. This work aims to verify the feasibility of using reduced scale outdoor models as a tool for validation of computer simulation of noise barriers. On the basis of experimental approach and exploratory nature, the application to the sound propagation in electrical substations is considered. The methodology involves the characterization of the sound source in question, the construction and testing of reduced scale model and modeling/simulation of the situation reproduced on a reduced scale with the software SoundPLAN 6.4®. The results of tests with scale outdoor model were used to validate computer simulation of acoustic barrier. It was concluded that it is possible to use reduced models for this purpose; however, it is necessary to evaluate the conditions of the environment during the tests. Among the characteristics of the environment to be evaluated, climatic variables at the time of measurement, background noise of the place, topography, soil type and presence of vegetation and buildings are considered. Such information can assist in obtaining reliable results and thus they guarantee the future performance of noise mitigation solutions through the use of reduced scale models for validating computer simulation / Doutorado / Arquitetura e Construção / Doutora em Engenharia Civil
33

Estudo de barreiras acusticas ao ar livre, sob a perspectativa de eficiencia e qualidade sonora

Neto, Maria de Fatima Ferreira 24 May 2002 (has links)
Orientador: Stelamaris Rolla Bertoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-01T21:56:33Z (GMT). No. of bitstreams: 1 Neto_MariadeFatimaFerreira_M.pdf: 3390488 bytes, checksum: 675867527ebf6bb839c6a6e6317a33a3 (MD5) Previous issue date: 2002 / Resumo: o estudo de barreiras acústicas ao ar livre é o objeto de estudo deste trabalho. Esse estudo abrange duas perspectivas:o desempenho acústico das barreiras e a qualidade sonora. Sobre as duas perspectivas,foram realizadas avaliações que compreendem aspectos objetivos e subjetivos. Entende-se como aspectos objetivosos resultadosdas medidasfisicas,como a perda por inserção das barreiras, para a avaliação do desempenho acústico e, os resultados dos parâmetros psicoacústicos definidos por Zwicker, para a avaliação da qualidade sonora. Em relação aos aspectos subjetivos, foi constituído um júri, que opinou sobre a sensação percebida de um estímulo sonoro,recebido através da barreira.Os resultadosdas avaliaçõesde ambos os aspectos, foram comparados a fim de se obter a avaliação final do desempenho das barreiras.A obstrução visual da fonte sonora, por uma barreira acústica, pode causar redução de ruído, nem sempre verdadeira.Os resultados mostram que o desempenho real das barreiras nem sempre corresponde ao desempenho subjetivo porém,reforçam a idéia de que as barreiras acústicas atuam como um auxiliar para a redução de ruído ao ar livre. Há fortes indícios de que os parâmetros psico acústicos poderão ser usados como método de desempenho de barreiras (qualidadesonora) / Abstract: The outdoor acoustic barriers study is the object of this work. This study includes two perspectives: the acoustic barrier performance and the sound quality. These two perspectives were evaluated considering objective and subjective aspects. The physical results, such as the barrier insertion loss, was used to evaluate the objective acoustic performance.The results from the psychoacoustic parameters defined by Zwickerwere used to objectively evaluate the sound quality. Regarding the subjective aspects, a jury was fonned to judge the perceived sensation ftom sonorous stimulus received through the barrier. The experimentalresults of both aspects were comparedto get the final evaluationof the acoustic barriers performance.The sound source visual obstruction caused by an acoustic barrier, ean cause noise reduction which is not always true. The results show that the barrier real performance does not always correspond to the subjective perfomacee,but also reinforce the idea that the acoustic barriersis an auxiliar element to reduce outdoor noise. There are strong evidencesthat the psychoacoustic parameters can be used as a means of barrier performace evaluation (soundquality) / Mestrado / Edificações / Mestre em Engenharia Civil
34

Niveis sonoros e exposição ao ruido em malharias. Estudos de caso : região de Jacutinga, MG

Bertucci, Wagner 05 July 1999 (has links)
Orientador: Stelamaris Rolla Bertoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-25T09:16:14Z (GMT). No. of bitstreams: 1 Bertucci_Wagner_M.pdf: 3122881 bytes, checksum: 91e94623658d550179f8cd49c3357184 (MD5) Previous issue date: 1999 / Resumo: O ruído é um dos principais problemas ocupacionais enfrentado pelos trabalhadores em malharias. A região de Jacutinga é um dos principais pólos de fabricação de malhas no país e existem poucas informações sobre os níveis de ruídos gerados por equipamentos e máquinas de malharias, bem como sobre a dose de exposição de ruído de seus trabalhadores. Este trabalho apresenta um estudo sobre os níveis de ruído gerados pelos diferentes tipos de máquinas empregados nas malharias. Analisa os diferentes espaços utilizados para a implantação das empresas e sua influência nos níveis de ruído. Levanta os tipos e marcas de máquinas utilizadas nas diferentes atividades de malharia. Investiga as características das máquinas através de seus espectros sonoros. Também nesse trabalho são apresentados os resultados das doses de exposição de ruído dos trabalhadores nas diferentes atividades dentro das - malharias. Os resultados encontrados sugerem cuidados especiais tanto sobre o espectro do ruído ambiente quanto o espectro de exposição. Os valores de níveis e dose de ruído ficaram na faixa de 80 a 85 dB(A), o que justifica a aplicação de plano de ação para o controle de ruído / Abstract: The noise is one of the main occupancy problems suffered by workers in knitted articles factories. The Jacutinga's region is one of the main points, where knitted articles are produced in Brazil, and there are few informations about noise levels due to knitted equipments and machines and how much the workers are exposed to this noise. This work presents a study about noise levels, due to many kinds of machines in knitted factories. It analyses different places used to implanting companies, and their influence on noise levels. It lists the types and marks of machines utilized in the different ways of production of knitted articles. It relates the machines attributes by their noise spectrums. Also in this work, are showed the results of noise exposition dose on workers, in different activities within the knitted factories. Since these results, it should be taken special attention as about local noise spectrum, as about - exposition spectrum. The noise levels and dose were among 80 and 85 dB(A), and this suggests the application of an action plan to controlling the noise / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
35

Controle ativo de vibrações em vigas e placas usando uma abordagem de intensidade estrutural / Active control oi vibmtion in beams and plates using a structuml intensity approach

Pereira, Allan Kardec Araujo 26 March 1999 (has links)
Orientador: Jose Roberto de França Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-25T10:44:12Z (GMT). No. of bitstreams: 1 Pereira_AllanKardecAraujo_D.pdf: 9794175 bytes, checksum: 619e00345631f64039182d262ce4f5e0 (MD5) Previous issue date: 1999 / Resumo: O objetivo deste trabalho foi estudar a aplicabilidade de uma metodologia de controle de vibrações em estruturas usando uma abordagem de intensidade estrutural (SI). Tal metodologia (ASIC) foi então aplicada ao estudo de vigas e placas em flexão. Técnicas de estimativa da SI em estruturas foram revistas e foram utilizados acelerômetros e sensores cerâmicos piezelétricos para as medidas de vibração. Para fins de controle, as estruturas foram identificadas usando algoritmos Q-Markov Cover e os modelos obtidos foram utilizados em simulações numéricas. Experimentos também foram implementados. Para o caso do controle da SI em vigas, o ASIC foi comparado com outras metodologias quais sejam, o FXLMS, o FXLMS MIMO e o método de Gibbs-Fuller. O ASIC se mostrou em média ligeiramente mais efetivo que o Gibbs-Fuller para os casos de excitação tonal e bastante mais efetivo para os casos de multi-frequência. Já para o caso de controle de placas, foi utilizada uma configuração com um atuador e oito sensores para a estimativa do divergente da SI. Tal configuração só permitiu atenuações locais para os casos estudados. Modificações na metodologia foram propostas e o controlador se transformou em controlador geral de intensidade, tanto acústica quanto estrutural / Abstract: The main goal of this work was to study the aplicability of a new methodology to control structural vibrations using a structural intensity approach. This methodology was then used to control flexural vibration in beams and plates. Techniques to estimate the structural intensity were revised. Accelerometers and piezelectric sensors were used in order to measure the vibration. The structures were identified using a Q-Markov Cover algorithm and the identified models were used in numerical simulations. Experiments were made using a DSP board. In the case of the beam, the ASIC was compared to the FXLMS, the MIMO FXLMS and the Gibbs-Fuller methods. The ASIC method performed slightly better throughout the investigated frequency range when compared to the Gibbs-Fuller method in the case of tonal excitation. For the case of multiple frequencies, the ASIC performed much better than the Gibbs-Fuller. In the case of the plate, only one actuator and eight sensors were used. With this configuration, the ASIC only controlled the vibrations locally. Some changes in the ASIC were proposed which made it a general intensity controller / Doutorado / Mecanica dos Sólidos e Projeto Mecanico / Doutor em Engenharia Mecânica
36

Um estudo do controle ativo de ruidos em dutos usando o algoritmo do minimo erro medio quadratico com referencia filtrada / A study of active noise control in ducts using reference filtered least mean square algorithm

Nunes, Ronaldo Fernandes 11 March 1999 (has links)
Orientador: Jose Maria Campos dos Santos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-25T19:56:09Z (GMT). No. of bitstreams: 1 Nunes_RonaldoFernandes_M.pdf: 5604429 bytes, checksum: 3e2d42b8a7421a42a727f76195057b6e (MD5) Previous issue date: 1999 / Resumo: Neste trabalho foi estudado o controle ativo de ruído em dutos usando técnicas de filtragem adaptativa. Foi utilizado o método de controle adaptativo do Mínimo Erro Médio Quadrático (Least Mean Square - LMS) normalizado com sinal de referência filtrado, NFXLMS. Três geometrias de dutos montados em uma bancada experimental para os casos de controle monocanal, multierro e multiexcitação foram verificados. Os sinais de perturbação investigados foram: tonal (seno), aleatório e uma com composição de duas senoidais no caso multiexcitação. Avaliações das impedâncias analíticas e experimentais foram verificadas no estudo de uma configuração do duto para o caso de controle monocanal. Simulações e experimentos foram realizados para diversas geometrias de dutos e diferentes tipos de excitação. Parâmetros do algoritmo, como o número de pesos do filtro adaptativo, faixa de frequência de perturbação, fator de convergência do algoritmo e freqüência de amostragem foram investigados nos casos tratados. Os resultados encontrados nos experimentos realizados para o controlador monocanal e multierro confirmaram as avaliações efetuadas nas simulações. Para o caso multiexcitação, limitações da placa de processamento de sinal não permitiram a obtenção de resultados conclusivos / Abstract: In this work was investigated the active control of noise in ducts using the techniques of adaptive filtering. The normalized, filtered reference Least Mean Square algorithm control method - NXLMS was used. Three shapes of duct system in a supported experimental test rig for the cases of control mono-channel, multi-error, and multi-input were verified. The investigated disturbance signals were: tonal (sine), random, and a composition of two sinusoids for the case of multi-input. Evaluations of analytical and experimental impedances were verified in a configuration study of mono-channel duct contraI case. Simulations and experiments were accomplished for several duct shapes and different types of excitations. AIgorithm parameters, such as the weight number of adaptive filter, the disturbance frequency range, the convergence factor of the algorithm, and the sampling frequency were investigated in the treated cases. The experimental results obtained for the mono-channel and multi-error controller confirm the evaluations obtained in the simulations. For the multi-input case, limitations of the DSP board didn't allow to obtain conclusive results / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
37

Estudo da absorção sonora de arranjos decorativos contendo espécies vegetais / Sound absorption study of decorative arrangements containning vegetable species

Vinadé, Rafael dos Santos 14 July 2015 (has links)
This study aims to present a sustainable alternative to noise attenuation in external or internal environments through the application of vegetated arrangements as sound absorbers. This proposal arises from the need to adapt the conventional sound absorption systems, and from the concern for environmental preservation. There was also concern about the decorative applicability of these systems, so its appearance should be aesthetically interesting. To compose the proposal, plant arrangements, containing the Buriti palm (Trithrinax brasiliensis Mart.), arranged in ornamental flowerpots build in MDF (Medium Density Fiberboard plank) and decorated with another plant, known as Barba-de-pau (Tillandsia usneoides) were analyzed. Measurements were performed to identify the sound absorption coefficient (α) of these arrangements, through experiments in reverberation chamber of the Acoustic Engineering Laboratory in the Federal University of Santa Maria, according to ISO 354/2003 standard using the interrupted noise method. From these tests, it was determined the reverberation time (RT) and subsequently the sound absorption coefficient α. The composition containing the two plants and the ornamental flowerpots presented the average sound absorption coefficient between 0,11 and 0,27 from 100 Hz to 5000 Hz range. Thus, it is recommended to use this alternative for noise attenuation in a given room, or using their application in series, containing combined vegetated arrangements. / Este estudo busca apresentar uma alternativa sustentável para atenuação de ruído em ambientes externos ou internos, através da aplicação de arranjos vegetados como absorvedores sonoros. Esta proposta surge da necessidade de adaptação dos sistemas convencionais de absorção sonora, bem como a partir da preocupação com a preservação ambiental. Há também a preocupação com a aplicabilidade decorativa destes sistemas, portanto, sua aparência deve ser esteticamente interessante. Para compor a proposta, houve a análise de arranjos de plantas contendo a palmeira Buriti (Trithrinax brasiliensis Mart.), montadas em cachepôs confeccionados em MDF (Painéis de fibra de média densidade) e decorados com outra planta, conhecida como Barba-de-pau (Tillandsia usneoides). Foram realizadas medições para identificar o coeficiente de absorção sonora α destes arranjos, através de ensaios desenvolvidos em câmara reverberante do Laboratório de Engenharia Acústica da Universidade Federal de Santa Maria, segundo a norma ISO 354/2003, empregando a metodologia de ruído interrompido. A composição contendo as duas plantas e o cachepôs em MDF apresentou o coeficiente de absorção sonora médio que variou entre 0,11 e 0,27 no intervalo de 100Hz até 5000Hz. Assim, recomenda-se a utilização desta alternativa para atenuação de ruído em um dado recinto, ou ainda utilizando sua aplicação em série, contendo vários arranjos vegetados combinados.
38

Avaliação das propriedades mecânicas e emissão de ruído de roldanas poliméricas de POM/TPU utilizadas na indústria moveleira

Roman Júnior, Celso 19 December 2014 (has links)
Misturas de poliacetal (POM), polímero de engenharia com boas propriedades mecânicas, com poliuretano termoplástico (TPU), um polímero composto por uma fase rígida e outra flexível visam buscar alternativa de materiais a serem utilizadas em bandas externas de roldanas, visando a diminuição da emissão de ruído das roldanas quando utilizadas em sistema de movimentação de portas de armários, em contato com um trilho metálico. Neste trabalho foram avaliadas as propriedades mecânicas, físicas, térmicas e morfológica de misturas de POM/TPU nas proporções 100/0, 80/20, 70/30, 60/40, 50/50, 40/60 e 0/100 (m/m). As misturas foram preparadas em extrusora dupla rosca corrotante e após os corpos de prova foram injetados em injetora convencional. O aumento dos teores de TPU nas misturas promoveu o aumento da resistência ao impacto, à abrasão e diminuição na dureza do material. Houveram aumentos da temperatura de deflexão térmica das misturas com o aumento do teor de POM. Através da microscopia eletrônica de varredura (MEV) pode ser analisada uma mistura homogênea com partículas dispersas de TPU em formato de gotículas. A avaliação de emissão de ruído mostrou que com a diminuição do módulo de elasticidade, com o aumento da quantidade TPU na mistura, ocorre a redução da emissão de ruído do mesmo, esta redução fica evidente em frequências acima de 1kHz, ocorrendo uma redução da emissão de ruído de 2-5dB. / Bolsa Desenvolvimento de Tecnologia e Inovação / Polyoxymethylene (POM), an engineering polymer with good mechanical properties, blended with thermoplastic polyurethane (TPU), a polymer composed by a flexible and a rigid phase, are an alternative of materials to be used in external bands of pulleys, aiming to reduce the noise emission of pulleys when used in system drive cabinets doors, occurring pulleys contact with a metallic rail. In this work, the mechanical, physical, thermal and morphological properties of POM/TPU blends were evaluated in the proportions of 100/0, 80/20, 70/30, 60/40, 50/50, 40/60 and 0/100 (w/w). The blends were prepared in a twin screw extruder and after the samples were injected in a conventional injector. The increase in the levels of TPU on the blends promoted a rise in the impact resistance, abrasion and a decrease in the material hardness. There was an increase in the deflection heat temperature of the blends with enhanced content of POM. Through scanning electron microscopy (SEM) was observed a blend with the presence of dispersed TPU particles. The noise emission showed that with the decrease in the modulus of elasticity of the polymer occurs a reduction of noise emission. This reduction is evident in frequencies above 1 kHz, causing 2-5dB reduction of noise emission.
39

Poluição sonora urbana: a influência de modificações em escapamentos de motocicletas na emissão de ruído / Urban noise pollution: influence of modifications on exhaust systems for noise emission

Forcetto, André Luiz Silva 11 April 2016 (has links)
A poluição sonora urbana, em especial a gerada por motocicletas com escapamentos modificados, afeta indistintamente a saúde de toda população de diversas maneiras e tende a aumentar, ao contrário da emissão de gases, que vem se reduzindo ao longo dos anos. Com o objetivo de conter o ruído gerado pelo tráfego urbano, vários países desenvolvem procedimentos, leis e ações mitigatórias como barreiras acústicas e asfaltos fonoabsorventes, porém há grande quantidade de motocicletas, veículo tipicamente de alto potencial de incômodo e ruidoso, que circulam com sistemas de escapamento adulterados e emitem ainda mais excesso de ruído. A inspeção veicular é ferramenta importante no controle de emissões de gases poluentes de veículos em uso, mas falha em restringir aqueles que ultrapassam os limites legais de ruído e, somado a isto, há o agravante de o condutor submeter-se a poluição sonora que ele mesmo produz. A fiscalização de rua surge como alternativa de controle ambiental, mas algumas vezes é contestada por ser subjetiva ou por faltar uma metodologia simples, confiável e eficaz. Buscou-se então compreender a relação entre o aumento do nível sonoro da motocicleta com escapamento modificado ao circular no trânsito e a emissão sonora medida na condição de inspeção, o chamado ruído parado, para trazer subsídios à formação de métodos mais eficazes de fiscalização e controle. Para isto foram avaliadas motocicletas quanto à emissão de ruído em circulação e ruído parado e os resultados obtidos apontam que os escapamentos modificados possuem nível sonoro muito mais elevado que os originais, com forte correspondência entre os dois métodos de medição. Esta poluição sonora atinge de modo particularmente intenso os profissionais, motoboys, que modificam suas motocicletas, pois eles se submetem a todos os fatores que favorecem a perda auditiva por excesso de ruído. Outras questões surgiram em paralelo ao tema principal e foram brevemente avaliadas para se compor o quadro geral, como o nível sonoro de escapamentos não originais avaliados segundo os procedimentos de homologação, a contribuição que a motocicleta traz ao ruído urbano e que resultados estes trazem quanto ao torque e potência da motocicleta. Estes estudos indicaram que a motocicleta modificada contribui fortemente para a poluição sonora urbana, afetando principalmente o condutor e sem trazer ganhos efetivos em termos de potência e dirigibilidade. / The urban noise pollution, in particular the one produced for motorcycles with tampered exhaust systems, affects indistinctly the health of all people in many ways and tends to grow up, in opposite to gaseous emissions, that is getting down through years. With the goal of mitigate noise generated from urban traffic, many countries develop procedures, laws and actions as acoustic barrier and phono absorbent asphalt, but there are still a great amount of motorcycles, typically a high annoying and noisy vehicle, running with tampered mufflers and producing excessive noise. In use vehicle inspection is an important tool on gaseous emissions control but fails to restrain excessive noise, a problem that get worse up due the rider is subjects him/herself to the own sound pollution. Roadside control comes as an alternative but sometimes is rejected as subjective or due a lack of a simple, easy, trustable method. This research looks for the relationship between increased sound level of modified motorcycles in traffic and noise emission in inspection mode, also known as stationary noise, to bring subsidies to develop more efficient control methods. For this, it were evaluated motorcycles for traffic and stationary noise emission and the results point that modified exhaust systems have a very higher sound level than original mufflers, with strong relationship between these two measurement methods. This sound pollution affects in a very special mode the professionals, called in Brazil motoboys, which modify their motorcycles, because they subjected themselves to all factors for noise-induced hearing loss. Other questions come in parallel to the main focus and were briefly studied in order to compound the whole picture as sound level of replacement mufflers according homologation procedures, the motorcycle contribution to the urban sound pollution and the results for power and torque. These studies point to that modified motorcycles strongly contribute to urban noise, affecting especially the driver and with no effective gain in engine power and motorcycle handling.
40

Análise e caracterização de soluções acústicas para mitigar os ruídos oriundos de instalações hidrossanitárias prediais. / Analysis and characterization of acoustical solutions to mitigate the noise from hydrossanitary systems in buildings.

Rocha, Raquel Rossatto 27 March 2018 (has links)
O ruído excessivo é considerado problema de saúde pública devido ao seu impacto a saúde humana. Nas edificações residenciais, os ruídos emitidos por instalações hidrossanitárias são maioria nas reclamações dos usuários. Neste contexto, destaca-se a necessidade do controle acústico em edificações residenciais, em específico deste estudo, para o controle do ruído hidrossanitário em instalações prediais. A norma NBR 15575: 2013 estabelece parâmetros para que os ruídos gerados por instalações hidrossanitárias não produzam níveis de pressão sonora elevados no interior dos dormitórios. Os níveis elevados provocam uma percepção auditiva desagradável e podem gerar constrangimentos entre vizinhos, devido à falta de privacidade. O objetivo deste artigo é avaliar e comparar os resultados de possíveis soluções acústicas para mitigar os níveis de pressão sonora gerados pelas instalações hidrossanitárias prediais, devido o acionamento de descargas de vasos sanitários e abertura de torneiras. Foram realizadas medições de níveis de pressão sonora conforme a norma ISO 16032: 2004 adaptada para laboratório em câmara de ensaios acústicos hidrossanitários do Instituto de Pesquisas Tecnológicas (IPT) para nove amostras de envelopamento acústico. Os resultados técnicos encontrados através das grandezas LZeq,nT, LAeq,nT e LASmax,nT foram analisados e comparados para cada amostra medida no tubo envelopado e no tubo aparente. Para as amostras analisadas, a maioria das amostras apresenta ? L >= 20 dB no acionamento da descarga do vaso sanitário e ? L >= 10 dB para o ruído oriundo da abertura da torneira. Através da estimativa custo-benefício, verificou-se que a amostra C possui a melhor relação entre as amostras estimadas. / Excessive noise is considered a public health problem due to its impact on human health. In residential buildings, the noises emitted by hydrosanitary are the source of most complaints from users. In this context, we highlight the need for acoustic control in residential buildings, in the specific case of this work, for the control of hydrosanitary systems noise in building. The standard NBR 15575: 2013 establishes parameters for the noises generated by hydrosanitary systems do not produce highs sound pressure levels inside the bedroom. When these levels are high, they cause a nasty hearing perception and can generate constraints between neighbors, due to the lack of privacy. The goal of this dissertation is to evaluate and analyze the results of possible acoustic solutions to mitigate the sound pressure levels generated by hydrosanitary systems, due to the triggering of discharge activation of toilets and tap opening. For this, measurements of sound pressure levels as ISO 16032: 2004 adapted to laboratory in acoustic testing environment hydrosanitary Instituto de Pesquisas Tecnológicas (IPT) to nine samples. Evaluated and compared the technical results found through the variable, LZeq,nT, LAeq,nT e LASmax,nT, for each sample as the tube enveloped and apparent tube. The results for the samples analysed are satisfactory, since most samples reduce more than 20 dB for noise generated due to the discharge activation and 10 dB for noise from the tap opening. Through the cost-benefit analysis, it was found that the sample C has the best relation between estimated samples.

Page generated in 0.1108 seconds