41 |
Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonizationCunha, Tatiana Ramirez 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (α=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (α=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
|
42 |
Resistência à tração entre componentes de pilar híbrido Conexão® submetido a teste de fadiga termomecânica / Tension strength between the two pieces of the hybrid abutment Conexão® after thermomechanical fatigue testBonachela, Clara Fassoni 21 September 2018 (has links)
Os pilares de próteses sobre implantes são determinantes para o sucesso final da restauração. Dentre os mais variados disponíveis no mercado, os pilares híbridos são uma proposta atual que propõe associar otimização da estética com performance biomecânica de qualidade à longo prazo. Sendo assim, o objetivo desse estudo foi verificar a resistência à tração entre os componentes do pilar híbrido parafusado Precision Link® (Conexão®) após ensaio de fadiga térmica e mecânica, através de uma metodologia inovadora proposta pelos autores. Foram utilizados 33 Conjuntos Precision Link 3,5 NP + Coping de Zircônia Base para Acrescentar 3,5 (Conexão), distribuídos em 3 grupos de 11 espécimes, nomeados de acordo com o número de ciclos mecânicos aos quais foram submetidos durante o teste de fadiga (Grupo Controle [G CONTROLE], Grupo de 240 000 ciclos [G1] e Grupo de 480 000 ciclos [G2]). Após o ensaio de fadiga termomecânica, os pilares foram submetidos a teste de tração, por meio de um dispositivo desenvolvido exclusivamente para esse trabalho, adaptado em uma máquina de ensaios universal. Os dados de resistência a tração foram submetidos à análise estatística através da análise de variância a 1 critério e Teste de Tukey para comparações individuais, mediante à qual foi identificada diferença estatisticamente significativa entre G1 e G CONTROLE e G1 e G2, tendo G1 demonstrado valores de resistência a tração menores que os outros grupos (Valores médios: G CONTROLE= 58,172 N, G1= 46,181 N, G2= 64,725 N). Pode-se concluir que a metodologia proposta para esse estudo, com o desenvolvimento de um dispositivo específico de tração é efetiva para identificar os valores de resistência à tração dos componentes de pilares híbridos parafusados Precision Link® (Conexão®) e a exposição aos ciclos termomecânicos testados no ensaio de fadiga influencia nos valores de tração entre os mesmos, primeiro diminuindo-os e depois aumentando-os de volta possivelmente por conta do fenômeno de degradação em baixa temperatura nos componentes de zircônia. / Implant abutments have a key role in the success of dental reabilitations. Among other options, hybrid abutments are a new option that can associate esthetic achievements with efficient long-term biomechanical performance. The purpose of this study was to verify the tension strenght between the components of the screw-retained hybrid abutment Precision Link® (Conexão®) after thermomechanical fatigue test, using an innovative approach. Thirty-three samples of Precision Link (d)3,5 NP + Zirconia Coping Add Base (d)3,5 (Conexão) were divided in three groups of eleven specimens each. The groups were divided by the number of mechanical cycles (Control Group [CONTROL G], Group of 240 000 cycles [G1] and Group of 480 000 cycles [G2]). After the thermomechanical fatigue test, the abutments were submitted to a tension strenght test in a specific device designed by the authors for this study. The referred device was coupled to an universal testing machine. Statistic analysis (ANOVA-1 e Tukey Test) showed G1 had statistical significative lower values of tension strenght than CONTROL G and also than G2. (Mean values: CONTROL G= 58,172 N, G1= 46,181 N, G2= 64,725 N) In conclusion, the methodology proposed for this study was effective in identifying the tension strenght values between the components of the screw-retained hybrid abutment Precision Link® (Conexão®). Also, the thermomechanical fatigue test influenced in the tension strenght values, first reducing the values of tension strenght, then increasing them back, by the transformation of phase of zirconia exposed to a wet environement.
|
43 |
Desenvolvimento de plataforma elíptica osseointegrável para implante dentário, guias de perfuração e técnica cirúrgica de implantação - estudo em fêmures de cães / Development of osseointegrated elliptic platform for dental implant, surgical guides and surgical technique of implantation study in femurs of dogsFerreira, Jonathan 10 February 2009 (has links)
O objetivo deste estudo foi desenvolver um implante dentário para utilização em cães, com formato semelhante aos dentes bi-radiculares destes animais e a técnica cirúrgica para sua implantação, com características que permitam a osseointegração. O implante é composto por três peças, dois implantes cônicos rosqueados unidos à plataforma elíptica cônica por parafusos e implantados abaixo do nível ósseo. Foram utilizados 20 fêmures de cães para o desenvolvimento deste projeto e os implantes foram colocados na região epifisária destes ossos. A perfuração foi guiada através de três tipos de guias cirúrgicas confeccionadas em alumínio com dimensões compatíveis a dos implantes e das plataformas. A osteotomia foi avaliada com mensurações diretas e a adaptação do implante foi avaliada radiograficamente. O implante desenvolvido é bastante semelhante à porção radicular dos dentes bi-radiculares dos cães. A técnica cirúrgica de perfuração e osteotomia foi eficiente e a avaliação radiográfica revelou boa adaptação entre as peças e paralelismo entre os implantes rosqueados. Essas conclusões permitem sugerir que, seguindo esta metodologia, com a plataforma confeccionada em liga de titânio, este tipo de implante deve se osteointegrar ao osso adjacente. / The aim of this study was to develop a dental implant for use in dogs with similar format to the biradicular teeth of these animals and surgical technique for its implantation, with features that allow the osseointegration. The implant is composed of three parts, two conic threaded implants united to a conic elliptical platform by screws and implanted below the bone level. 20 femurs of dogs were used for the development of this project and the implants were placed in the epiphyseal region of the bones. The drilling was guided by three types of surgical guides made of aluminum consistent with dimensions of the implants and platforms. The osteotomy was evaluated with direct measurements and the adaptation of the implant was evaluated radiographically. The implant developed is very similar to the root portion of the biradicular teeth of dogs, the surgical technique of drilling and osteotomy have been efficient and radiographic evaluation showed good adaptation between the parts and parallelism between the threaded implants. These findings suggest that by following this approach, with the platform constructed in titanium, this type of implant should be osseointegrated to the adjacent bone.
|
44 |
Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonizationTatiana Ramirez Cunha 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (α=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (α=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
|
45 |
Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro / Microbiological analysis of the seal with industrial sealant on the microgaps in the different implant connections: in vitro studyTunes, Fábio Sanches Magalhães 29 June 2018 (has links)
A utilização de implantes osseointegráveis e componentes protéticos tornaram-se recursos muito viáveis à resolução de casos simples e complexos na odontologia reabilitadora. No entanto, a junção implante componente pode apresentar problemas, tais como a presença de um microgap entre essas partes constituintes. Assim, vários materiais tem sido testados na tentativa de obstruir esse espaço, com resultados controversos. O objetivo deste estudo foi avaliar in vitro o comportamento de um adesivo anaeróbico (Loctite® 510, Henkel Ltda) monocomponente, de alta resistência e inerte, na vedação do microgap impedindo a passagem bacteriana do meio externo para o interno do conjunto. Foram utilizados 90 implantes de conexão externa hexagonal (n = 30), conexão interna hexagonal (n = 30) e conexão interna cônica (n = 30), divididos em Grupo Controle (n = 45) e Grupo Teste (n = 45). Os implantes foram abertos em fluxo laminar e cada unidade recebeu 3l de BHI estéril internamente. Sobre cada unidade era parafusado um componente protético especifico para cada marca e com torques recomendados pelos fabricantes com torquímetro digital. Os conjuntos Teste receberam ainda uma fina camada de adesivo que era aplicada com microbrush entre as partes; e todas as unidades dos grupos Controle e Teste foram vedados com material obturador provisório na sua porção mais coronal. Cada conjunto foi então imerso em 75 l de Enterococcus faecalis (ATCC 29212) em minitubos até o limite entre a junção implante/componente protético. Todas as amostras foram incubadas em estufa bacteriológica por 7, 14 e 28 dias a 37oC antes de serem reabertas. Após o período proposto, o conteúdo interno dos implantes foi coletado com cones de papel estéreis, diluído e semeado em placas de Petri, incubadas por 48 horas. Houve diferença significante entre o grupo teste e controle no grupo de conexão externa hexagonal, em todos os tempos (Teste de Fischer e Qui-quadrado, p 0.05). O adesivo anaeróbico testado funciona como barreira, não permitindo a migração de bactérias para o meio interno do conjunto implante/componente protético. / The use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
|
46 |
Efeito de terapia fotodinâmica utilizando curcumina como fotossensibilizante sobre o biofilme de S. gordonii formado sobre superfícies lisa e rugosa de titânio / Effect of photodynamic therapy using curcumin as a photosensitizer on the S. gordonii biofilm formed on smooth and rough surfaces of titaniumRancan, Flavia Luiza 13 March 2017 (has links)
A prevenção das doenças periimplantares baseia-se em procedimentos de rotina na clínica, com a remoção mecânica do biofilme associada ou não de agentes antimicrobianos locais e sistêmicos. No entanto, o controle do biofilme oral sobre a superfície de implantes é dificultado particularmente sobre as superfícies rugosas do titânio, que apesar de facilitarem a osseointegração, também favorecem a formação do biofilme. Objetivos: Objetivou-se analisar in vitro o efeito da TFD (Terapia fotodinâmica) usando curcumina como fotossensibilizador sobre o biofilme formado na superfície de discos de titânio com superfície rugosa e lisa. Material e Métodos: Biofilme mono espécie de Streptococus gordonii, colonizador inicial do biofilme dental, foi formado em superfícies lisas (usinadas) e rugosas (tratadas) de discos de titânio por 72 horas. Os discos lisos e rugosos foram então distribuídos em 3 grupos: tratados por 5 minutos com curcumina (60?M), clorexidina 0,12% como controle positivo e solução de DMSO (dimetilsufóxido), etanol e água como controle negativo (veículo da curcumina). As amostras foram divididas em 2 sub-grupos: ativado por LED azul (455-492nm) por 7 minutos e não-ativado. A atividade metabólica do biofilme foi determinada pelo método de redução do Sal tetralisol XTT e os resultados analisados estatisticamente pela análise da variância (ANOVA) seguida pelo teste de Tukey (p < 0,05). Resultados: Na ausência de luz, apenas o tratamento com clorexidina promoveu redução microbiana (controle positivo). O tratamento com curcumina ativada pela luz azul reduziu o número de bactérias viáveis no biofilme em 71% nos discos lisos e em 77% nos rugosos, não havendo diferença estatística com o controlepositivo.Conclusão: Os dados in vitro indicam que TFD associada à curcumina tem atividade sobre biofilme microbiano, sugerindo seu potencial no controle do biofilme oral sobre a superfície de titânio, e que este efeito independe da topografia da superfície. / Prevention of periimplant diseases is based on routine procedures in the clinic, with the mechanical removal of biofilm associated or not with local and systemic antimicrobial agents. However, the control of oral biofilm on the surface of implants is particularly difficult on the rough surfaces of titanium, which, although facilitating osseointegration, also favors biofilm formation. Objectives: The objective of this study was to analyze in vitro the effect of PDT using curcumin as a photosensitizer on the biofilm formed on the surface of titanium discs with a rough and smooth surface. Material and Methods: Biofilm mono species of Streptococus gordonii, initial colonizer of the dental biofilm, was formed on smooth (machined) and rough (treated) surfaces of titanium discs for 72 hours. The smooth and rough discs were then divided into 3 groups: treated for 5 minutes with curcumin (60 ?M), 0.1% chlorhexidine as a positive control and DMSO, ethanol and water solution as a negative control. The samples were divided into 2 subgroups: activated by blue LED (455-492nm) for 7 minutes and non-activated. The metabolic activity of the biofilm was determined by the reduction XTT salt method and the results analyzed statistically by ANOVA followed by the Tukey\'s test (p <0.05) Results: In the absence of light, only the chlorhexidine treatment promoted microbial reduction (positive control). The blue light-activated curcumin treatment reduced the number of viable bacteria in the biofilm in 71% in the smooth discs and in 77% in the wrinkles, and there was no statistical difference with the positive control. Conclusion: In vitro data indicate that PDT associated with curcumin has activity on microbial biofilm, suggesting its potential in the control of oral biofilm on the titanium surface, and that this effect is independent of surface topography.
|
47 |
Análise da durabilidade, retenção e tensão em overdentures retidas por implantes associadas ou não a mini-implantes posteriores / Durability, retention and stress analysis of implants-retained overdentures associated or not to posterior mini-implantsAlves, Suleima do Vale 02 June 2017 (has links)
O objetivo desse estudo in vitro foi analisar a durabilidade, retenção e tensão gerada nos implantes de overdenture retidas por sistema bola/O\'ring ou barra/clipe, associados ou não a mini-implantes na região posterior da mandíbula. Foram utilizados implantes anteriores cone-Morse (3,75 x 11 mm) e mini-implantes de corpo único (2 x 10 mm) e os grupos divididos em (n=12): G2O: overdenture sobre 2 implantes com bola/O´rings; G1B: overdenture sobre 2 implantes com barra/clipe; G4O: overdenture sobre 2 implantes com bola/O´rings e 2 mini-implantes na região posterior; G1B2O: overdenture sobre 2 implantes com barra/clipe e 2 mini-implantes na região posterior. Para avaliação qualitativa das áreas de compressão e/ou tração nos modelos em poliuretano, foi realizado o método de correlação de imagens digitais, com carregamento oclusal (300 N) e pontual (250 N) com captura em vista frontal e lateral dos modelos experimentais. Foi realizado ensaio de fadiga acelerada progressiva com cargas de 80 N, 140 N, 200 N, 260 N, 320 N e 380 N, frequência de 5Hz, totalizando 120.000 ciclos. Para avaliação da retenção os modelos foram submetidos a ensaio de tração previamente a termociclagem (Tempo 1), após 200 N (Tempo 2) e após 380 N (Tempo 3) e a força de retenção foi registradas em triplicata e a média obtida em cada tempo. A análise da durabilidade dos componentes retentivos foi realizada após os ensaios de tração nos tempos determinados por microscopia óptica. As imagens da aplicação de carga oclusal, mostraram que as tensões nos grupos 1B e 1B2O foram semelhantes, nos grupos 2O e 4O apresentaram tensões de tração na região anterior, porém no grupo 4O houve melhor distribuição por toda área analisada. Na aplicação de carga pontual, todos os modelos apresentaram tensões de compressão na região posterior e de tração na anterior, porém com maior intensidade nos modelos 2O e 4O, e menor intensidade nos modelos 1B e 1B2O. Nas análises sobre a retenção dos componentes, não houve diferença significativa (p < 0,05) entre os grupos 1B-1B2O, porém houve diferença significativa entre os grupos 2O-4O, notando maior força retentiva no grupo 4O. As comparações entre os grupos, 1B-2O e 1B2O-4O houve diferença significativa, sendo que os grupos com sistema barra/clipe obtiveram maior retenção que os grupos com O´rings. Nas imagens microscópicas não houve diferença significativa na estrutura interna dos O´rings, porém houve diferença significativa nos clipes. Conclui-se que a durabilidade, retenção e distribuição de tensão não se altera com a colocação de mini-implantes posteriores em overdentures com sistema retentivo barra/clipe. Com sistema retentivo bola/O\'ring a instalação de mini-implantes aumentou a força de retenção e favoreceu a distribuição das tensões, reduzindo a alavanca para posterior. / The purpose of this in vitro study was to analyze the durability, retention and strength caused for implants-retained overdentures by ball/O-ring system or bar/clip, associated or not mini-implants in the posterior region of the mandible. Anterior Morse taper connection implants (3.75 x 11 mm) and single-body mini-implants (2 x 10 mm) were used and the groups divided to (n=12): G2O: implants-retained overdentures 2 implants with ball/O-rings ; G1B: implants-retained overdentures 2 bar/clip implants; G4O: implants-retained overdentures 2 implants with ball/O-rings and 2 mini-implants in the posterior region ; G1B2O: implants-retained overdentures 2 implants with bar/clip and 2 mini-implants in the posterior region. For the qualitative evaluation of compression and/or traction areas in polyurethane models, a digital image correlation method (DIC) with occlusal (300 N) and punctual (250 N) loading was applied with frontal and lateral views of the experimental models. An accelerated progressive fatigue test with loads of 80 N, 140 N, 200 N, 260 N, 320 N and 380 N, frequency of 5 Hz, completing120,000 cycles. In order to evaluate the retention force, the models were submitted to traction force, previously to thermocycling (Time 1) after 200 N (Time 2) and posteriorly 380 N (Time 3), being the retention force recorded in triplicate. The durability analysis, by optic microscopy, of the retentive components was performed after the traction tests at the determined times. The application images of the occlusal load, showed that the stress in groups 1B and 1B2O were similar, in groups 2O and 4O presented stress in the anterior region, but in the 4O group, there was better distribution throughout the analyzed area. In the application of punctual loading, all the models presented compression tensions in the posterior region and traction in the anterior one, but with greater intensity in the 2O and 4O models, and lower intensity in the 1B and 1B2O models. In the retention analyzes of the components, there was no significant difference (p <0.05) between groups 1B-1B2O, but there was a significant difference between groups 2O-4O, noting a higher retentive force in the 4O group. The comparisons between the groups, 1B-2O and 1B2O-4O showed a significant difference, and the groups with bar/clip systems obtained higher retention than the groups with O-rings. In the microscopic images, there was no significant difference in the O-rings internal structure, but there was a significant difference in the clips images. It was concluded that the durability, retention and stress distribution do not change with the placement of posterior mini-implants in overdentures with retentive bar/clip system. With retentive system ball/O-ring the installation of mini-implants increased the retention force and favored much the distribution of the stress, thus reducing the forefoot leverage to the posterior part of the prosthesis.
|
48 |
Efeito do jateamento com óxido de alumínio e uso de adesivo, no afrouxamento do parafuso de pilares protéticos cônicos, com indexador de restaurações implanto suportadas / Effect of aluminium oxide blasting and use of adhesive on abutment screw loosening torque of morse taper with index for implant-supported restorationsHirayama, Patrícia Mitiko Asanuma 26 September 2012 (has links)
O sucesso dos trabalhos protéticos, executados sobre os implantes osseointegrados, depende da estabilidade da conexão entre implante e pilar protético. Dentre as conexões protéticas existentes, as conexões cônicas têm demonstrado um desempenho melhor, tanto em termos mecânicos, como biológicos. A retenção friccional do pilar cônico é a grande responsável pela resistência aos movimentos laterais e oclusais da mastigação. Com a introdução de indexadores no desenho dessas conexões a característica mecânica mudou, levantando dúvidas em relação a sua atuação. Neste trabalho, avaliou-se o efeito do jateamento e uso do adesivo no torque de desaperto dessas conexões. Vinte e oito pilares synOCta® da marca Straumann® foram avaliados quanto ao torque de aperto inicial de 35 N.cm e torque de desaperto após ciclagem mecânica. Três grupos experimentais foram testados em relação ao grupo controle: modificação da superfície cônica por jateamento com óxido de alumínio, aplicação de adesivo entre as partes e o jateamento mais o adesivo. O grupo jateamento com aplicação do adesivo foi o único que apresentou valores de desaperto superiores quando comparado ao grupo controle. A rugosidade criada pelo jateamento, associada ao adesivo, elevou significantemente os valores de torque de desaperto do parafuso em comparação ao torque de aperto. / The success of the prosthetic work performed over dental implants depends on the stability of the connection between implant and abutment. Among the existing prosthetic connections, the conical connections have shown better performance, both mechanical and biological. The frictional retention of the morse taper is largely responsible for the resistance to lateral and occlusal movements of mastication. With the introduction of indexes in the design of these connections, the mechanical characteristic changed, raising doubts about its performance. In this study, we evaluated the effect of blasting and use of adhesive on abutment screw loosening torque of these connections. Twenty-eight synOcta® pillars Straumann® brand were evaluated for initial tightening torque of 35 N.cm and loosening torque after mechanical cycling. Three experimental groups were tested related to the control group: modification of the conical surface by blasting with aluminum oxide, aplication of adhesive between the parties and blasting added to the adhesive. The group blasted with adhesive application was the only one that showed values of loosening torque higher when compared to control group. The roughness created by blasting associated with the adhesive, significantly elevated values of abutment screw loosening torque against the tightening torque.
|
49 |
Avaliação da influência da força de mordida na prótese parcial removível classe I mandibular associada ao implante osseointegrado, pelo método dos elementos finitos /Lucas, Liliana Vicente Melo de. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Resumo: A associação entre as próteses parciais removíveis e os implantes osseointegrados é, ainda, uma opção de tratamento muito pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), localizado na região posterior do rebordo alveolar desdentado, atuando como suporte para a base da prótese. Para tanto, foram criados três modelos, os quais, em corte sagital, representam: modelo A (MA) - hemiarco contendo o dente natural 33 somente e o A rebordo desdentado distal; modelo B (MB) - semelhante ao MA, com uma PPREL convencional substituindo os dentes ausentes; modelo C (MC) - semelhante ao anterior, com um implante na região posterior do rebordo, sob a base da prótese. Com o auxílio do programa de elementos finitos ANSYS 5.4, os modelos foram carregados com forças verticais e oblíquas de 45º, tanto no sentido de mesial para distal como no sentido inverso, de magnitude de 50 N, em cada ponta de cúspide. A análise dos mapas de tensões permitiu concluir que: 1) a tendência de deslocamento no modelo com a PPR apoiada sobre implante é menor que no modelo com a prótese somente; 2) as forças oblíquas de 45º promovem uma tendência de deslocamento e valores de tensão maiores que a força vertical; 3) a força oblíqua de 45º, no sentido de mesial para distal, gera valores de tensão menores que a de distal para mesial e 4) a presença do implante osseointegrado, sob a base da prótese, promove alívio do dente suporte. / Abstract: The association among the removable partial dentures and the osseointegrated implants is still a non very explored option of treatment in the modern prosthetic dentistry. Because of this, the objective of this study is to evaluate, using the two-dimensional finite element analysis, the tension distribution in the support structures of the distal extension removable partial denture (RPD) associated with a 10.0 x 3.75 mm osseointegrated implant (Branemark System), located in the posterior area of the toothless alveolar edge, acting as support for the prosthesis base. Then, three plane strain models were created, represented in sagital cut: Model A (MA) - hemiarc containing the natural tooth 33 and the toothless alveolar edge; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with an implant in the posterior area of the edge, under the denture base. With the aid of the finite element program ANSYS 5.4, the models were loaded with vertical and 45º inclined forces, in both mesial and distal sides, with 50 N, on each peak point. The analysis of the tensions map allowed to conclude that: 1) the displacement tendency in the model with the RPD supported by the implant is smaller than the model with prosthesis only; 2) the oblique forces of 45º promote a displacement tendency and larger tension values than the vertical force; 3) the mesial to distal 45º oblique force generates smaller tension values than the one of distal to mesial and 4) the presence of the osseointegrated implant, under the denture base, promotes relief to the support tooth. / Mestre
|
50 |
Ostéo-intégration des implants dentaires à partir de l’étude de recherche clinique ZIR-ROC : matériaux, techniques opératoires, limites et perspectives / Dental implant Osseointegration : ZIR-ROC clinical research : materials, operative surgery, limits and perspectivesFauroux, Marie-Alix 13 December 2016 (has links)
Introduction : Depuis les premiers implants dentaires Bränemark, les techniques chirurgicales et les matériaux implantaires ont évolué. La référence en terme de matériau implantaire est le Titane. Cependant, d’autres matériaux comme le Zircone ont été proposés pour suppléer le Titane en cas d’allergie au Titane mais aussi pour améliorer la bio-intégration de l’implant dentaire et l’esthétique. Les facteurs de risques d’échec implantaire des implants en Titane incluent, entre autre, l’hygiène orale, la consommation de tabac et la mise en charge immédiate. Objectif : L’étude ZIR-ROC a donc été menée dans le but d’étudier le taux de survie de ces implants zircone après 2 ans de suivi, de recueillir des informations sur l’intégration tissulaire des implants et de rechercher les facteurs de risque d’échec des implants en Zircone. Matériel et méthode : l’étude ZIR-ROC a été menée dans le service de chirurgie orale du CHU de Montpellier sur des implants monobloc en Zircone de la société Paris Implant®. La pose de 43 implants a été déterminée pour permettre l’analyse statistique des résultats. Le forage et l’insertion des implants ont été réalisés à l’aide du système de chirurgie guidée 2ingis®. La variable principale pour évaluer l’ostéo-intégration des implants a été le score délivré par le Periotest®. 22 variables secondaires ont été recueillies tels que les indices gingivaux et de plaque ainsi que l’analyse rétro-alvéolaire. Les données ont été relevées juste avant la chirurgie implantaire, ainsi qu’à 1 semaine, 4 semaines, 5 mois, 1 an et 2 ans. La méthode de Kaplan-Meier, le modèle de Cox et les analyses en composantes principales ont été utilisés pour l’analyse statistique. Résultats : Tous les implants ont présenté une bonne stabilité primaire post-opératoire (valeurs du Periotest comprises entre -8 et +1 ; moyenne à -5,7). Le taux d’échec implantaire a atteint 31% après les 5 premiers mois d’ostéo-intégration. Une mobilité clinique a été observée pour les implants perdus. Les facteurs de risque décrits dans la littérature ont été retrouvés dans le modèle de Cox avec une significativité pour la consommation de tabac et d’alcool et sans significativité statistique pour la densité osseuse ou encore la mise en place d’une couronne provisoire. Par ailleurs, la présence de plaque et d’inflammation gingivale a été observée en faible quantité sur les implants en Zircone. Discussion et conclusion : Le Zircone apparaît comme un matériau biocompatible pour des implants dentaires. Les causes des échecs implantaires précoces observés sont probablement multiples et cette étude n’a pas permis de démontrer l’implication seule de la Zircone dans ces échecs. La recherche des facteurs d’échecs implantaires a conduit à évaluer la technique chirurgicale utilisée pour cette étude mais aussi le dessin de l’implant. De plus, une étude in vitro comparant des implants à base de Zircone et de Titane a été entreprise pour évaluer l’affinité de cellules souches d’origine dentaire pour les 2 matériaux. / Introduction: Since first Bränemark dental implants were implanted, operative surgery and materials for implantation have evolved. Titanium was the gold standard for dental implant material. But others materials like Zirconium were studied in replacement of Titanium due to allergy, bio-integration end aesthetic reasons. Contributing risk factors of Titanium implant failure include oral hygiene, tabacco and early loading among others factors. Objective: The aim of this clinical study was to evaluate survival rate of Zircon implants after 2 years, to collect information for tissue integration of Zirconium implant and to identify risk factors for Zircon implant failure. Material and Methods: ZIR-ROC study, conducted in the Oral Surgery Departement in Montpellier University Hospital, used zircon monobloc (ZIR-ROC®) implants (Paris Implant Society®). 43 implants were required for statistical analysis. Drilling and implantation were conducted with 2ingis® surgical guide system. The Periotest® value was the first endpoint for the implant osseointegration analysis. Gingival and dental plaque indices as well as intraoral X-ray analysis were part of the 22 secondary variables. Data were collected just after implantation surgery, and then, 1 week, 4 weeks, 5 months, 1 year and 2 years after implantation. Kaplan-Meier method, Cox regression model and principal component analysis were used for statistical analysis. Results: All implants showed postoperative optimal primary stability (Periotest® values between -8 and +1; mean: -5,7). Implants failure rate reached 31 percent after the 5 initial months of osseointegration. Clinical mobility was observed for the failed implants. Risk factors published in the scientific literature were observed in the Cox regression model with significant statistical effect for tobacco and alcohol consumption but without significant statistical effect for osseous density or even temporary crown insertion. Furthermore, gingival inflammation and dental plaque presence were low on Zircon implant. Discussion and Conclusion: Zirconium remains a biocompatible material for dental implantation but there were probably many reasons for the observed early implant failures and this study could not demonstrate the only involvement of Zirconium based material. Operative surgery used in this clinical study and the design of the implants were studied for researching other risk factors. In addition, an in vitro study comparing Zirconium versus Titanium as gold standard, was conducted for testing affinity of dental stems cells on Titanium and Zirconium-based dental materials.
|
Page generated in 0.0901 seconds