251

Optimisation de la structure globale des activités de surface d’une centrale géothermique à cogénération électricité/chaleur / Optimization of the overall structure for the surface activities in a geothermal combined heat and power plant

Marty, Fabien 27 November 2017 (has links)
Dirigé par la société Fonroche Géothermie, un consortium de dix partenaires participe au projet FONGEOSEC qui s’inscrit dans le cadre des Investissements d’Avenir de l’ADEME. Ce projet a pour but de concevoir et de réaliser un démonstrateur innovant de centrale géothermique haute enthalpie. L’énergie, ainsi récupérée en profondeur, servira à la cogénération d’électricité et de chaleur. L’une des étapes du projet correspond à l’objectif de cette thèse : développer une méthodologie pour la conception optimale des activités de surface de la centrale géothermique. Il s’agit donc de formuler le problème d’optimisation, de proposer une stratégie de résolution robuste et enfin, de mettre en oeuvre cette stratégie grâce à un outil logiciel.Dans l’outil ainsi développé, la répartition entre la production d’électricité et de chaleur s’effectue en parallèle. Le fluide géothermal est séparé en deux courants, l’un alimentant un Cycle Organique de Rankine (ORC : Organic Rankine Cycle) pour la production d’électricité, et l’autre étant relié à un Réseau de Chaleur Urbain (RCU) pour la distribution de la chaleur. Chaque constituant de l’ORC est dimensionné et la topologie du RCU est déterminée. Cet outil permet alors de déterminer simultanément :quelle est la meilleure répartition entre production d’électricité et de chaleur,quelles sont les meilleures dimensions pour les composants de l’ORC,et quelle est la meilleure topologie du RCU.Concernant l’ORC, l’outil permettra de savoir si l’utilisation d’un éventuel récupérateur de chaleur interne (IHE : Internal Heat Exchanger) est avantageuse ou non. Du point de vue du RCU, tous les consommateurs (sous-stations) envisagés ne sont pas obligatoires. L’outil permettra de choisir quels consommateurs relier au réseau et dans quelle disposition. L’utilisation de variables discrètes est alors nécessaire et le problème d’optimisation ainsi résolu est un problème de type MINLP (Mixed Integer Non Linear Programming).Une méthodologie de résolution permettant l’obtention d’une solution de « confiance » (probablement, mais non certainement, l’optimum global) est proposée. Cette stratégie de résolution est testée pour différents cas d’étude proches des conditions du projet FONGEOSEC. La stabilité et la robustesse de cette stratégie sont alors mises en avant. Une analyse économique et une analyse énergétique sont réalisées. La résolution multi-objectif est alors effectuée dans le but de fournir le meilleur compromis entre bénéfices annuels nets et destruction d’exergie. Pour finir, la diversité des résultats montre qu’il n’est pas satisfaisant de dissocier les études des deux systèmes (ORC et RCU) et démontre l’intérêt de l’outil développé. / A consortium of ten partners, led by “FONROCHE Géothermie”, works on the FONGEOSEC project, an “Investissement d’Avenir” organized by the French Agency for Environment and Energy (ADEME). The aim of this project is to design and create an innovative demonstrator of a high-energy geothermal power plant. The geothermal energy will be used to produce electricity and heat. Among other tasks, this project aims to develop a support tool for the optimal design of the structure for the surface activities in the geothermal plant.Within the developed tool, the repartition between electricity and heat production is in parallel. The geothermal fluid is split in two streams, one is used for an Organic Rankine Cycle (ORC) for electricity production, and the other is connected to a District Heating Network (DHN) for the heat distribution. This tool enables to determine simultaneously:which is the best repartition between electricity and heat,which is the best sizing for ORC components,which is the best configuration for the DHN.About the ORC, the tool will enable to decide if the use of an Internal Heat Exchanger (IHE) is interesting or not. For the DHN point of view, all the consumers envisaged are not mandatory. The tool will enable to choose which consumers it is better to connect to the network and in which disposition. The use of discrete variables is necessary and the optimization problem to be solved is a MINLP (Mixed Integer Non Linear Programming) problem.A solution strategy is implemented in order to obtain a confident solution with a determinist algorithm. This strategy is tested for different study cases close to FONGEOSEC conditions. Stability and Robustness of this strategy are then highlighted. An economic and an exergetic analysis are carried out. In order to find a good compromise between the two objectives, a multi-objective solution is performed. Finally, the diversity of results obtained shows it is not suitable to dissociate ORC and DHN studies and shows the interest of the developed tool.
252

Thermal storage solutions for a building in a 4th generation district heating system : Development of a dynamic building model in Modelica

Eriksson, Rickard, Andersson, Pontus January 2018 (has links)
The world is constantly striving towards a more sustainable living, where every part of contribution is greatly appreciated. When it comes to heating of buildings, district heating is often the main source of heat. During specific times, peak demands are created by the tenants who are demanding a lot of heat at the same time. This demand peak puts a high load on the piping system as well as the need for certain peak boilers that run on non-environmental friendly peak fuel. One solution that is presented in this degree project that solves the time difference between production and demand is by utilizing thermal storage solutions. A dynamic district heated building model is developed with proper heat propagation in the pipelines, thermal inertia in the building and heat losses through the walls of the building. This is all done utilizing 4th generation district heating temperatures. Modelica is the tool that was used to simulate different scenarios, where the preheating of indoor temperature is done to mitigate the possibility for demand peaks. Using an already existing model, implementation and adjustments are done to simulate thermal storage and investigate its effectiveness in a 4th generation district heating system. The results show that short-term energy storage is a viable solution in concrete buildings due to high building mass. However, combining both 4th generation district heating with storage in thermal mass is shown not to be suitable due to low temperatures of supply water, which is not able to increase the temperature of the building’s mass enough.
253

Energy Efficient Renovation Strategies for Swedish and Other European Residential and Office Buildings

Gustafsson, Marcus January 2017 (has links)
The high energy use in the European building stock is attributable to the large share of old buildings with poor energy performance. Energy renovation of buildings is therefore vital in the work towards energy efficiency and reduced environmental impact in the EU. Yet, the strategies and energy system implications of this work have not been made clear, and the rate of building renovation is currently very low. The aim of this thesis is to investigate the economic and environmental aspects of energy renovation strategies, with two main objectives: Renovation of Swedish district heated multi-family houses, including life-cycle cost and environmental analysis and impact on the local energy system; Renovation of European residential and office buildings, including life-cycle cost and environmental analysis and influence of climatic conditions. Buildings typical for the respective regions and the period of construction 1945-1970 were simulated, in order to determine the feasibility and energy saving potential of energy renovation measures in European climates. A variety of systems for heating, cooling and ventilation were studied, as well as solar energy systems, with focus on heat pumps, district heating, low-temperature heating systems and air heat recovery. Compared to normal building renovation, energy renovation can often reduce the life-cycle costs and environmental impact. In renovation of typical European office buildings, as well as Southern European multi-family houses, more ambitious renovation levels can also be more profitable. Exhaust air heat pumps can be cost-effective complements in district heated multi-family houses, while ventilation with heat recovery is more expensive but also more likely to reduce the primary energy use. From a system perspective, simple exhaust ventilation can reduce the primary energy use in the district-heating plant as much as an exhaust air heat pump, due to the lower electricity use. / Byggnadssektorn står för omkring 40 % av den totala energianvändningen i EU. Den höga energianvändningen i Europeiska byggnader kan till stor del tillskrivas den stora andelen gamla byggnader med dålig energiprestanda. Energirenovering av byggnader, eller energieffektivisering genom renovering, kan därför anses utgöra en central del i arbetet mot EU:s klimat- och energimål för år 2030. Trots detta är det ännu inte helt klarlagt vilka strategier som ska tillämpas för att uppnå detta och hur det påverkar energisystemet, och i nuläget är renoveringstakten fortfarande väldigt låg. Målet med denna avhandling är att undersöka ekonomiska och miljömässiga aspekter av strategier för energirenovering, såväl byggnadsskalsåtgärder som aktiva system, för typiska bostads- och kontorsbyggnader i Sverige och i andra Europeiska regioner. Mer specifikt har arbetet följande två inriktningar: Renovering av svenska, fjärrvärmevärmda flerfamiljshus, inklusive livscykelkostnadsanalys och livscykelmiljöanalys samt påverkan på det lokala energisystemet; Renovering av Europeiska bostads- och kontorsbyggnader, inklusive livscykelkostnadsanalys och livscykelmiljöanalys samt påverkan av klimatförutsättningar. Byggnader typiska för respektive region och byggnadsperioden 1945-1970 modellerades och användes i simuleringar för att fastställa den övergripande möjligheten och energibesparingspotentialen för olika renoveringsåtgärder i Europeiska klimat. En rad system för värme, kyla och ventilation studeras, samt solenergisystem, med fokus på värmepumpar, fjärrvärme, lågtemperaturvärmesystem och värmeåtervinning ur frånluft. Jämfört med renovering av byggnader utan energieffektiviseringsåtgärder kan energirenovering i många fall minska såväl livscykelkostnaden som miljöpåverkan. Vid renovering av typiska Europeiska kontorsbyggnader lönar det sig mer att renovera ner till ett uppvärmningsbehov på 25 kWh/(m²∙år) än 45 kWh/(m²∙år), då den minskade kostnaden för köpt energi väger upp den ökade kostnaden för isolering. För flerfamiljshus i södra Europa kan mer ambitiösa mål gällande värmebehov också vara lönsamma, medan en mer måttlig nivå är lämplig för småhus. Solvärme- eller solelsystem kan användas för att minska byggnaders miljöpåverkan. Utan subventioner eller inmatningstariff för överskottsel kan det bli svårt att få lönsamhet i dessa system för kontorsbyggnader i Nord- och Centraleuropa samt för småhus. För flerfamiljshus kan solenergisystem dock sänka den totala livscykelkostnaden, såväl i södra som i norra Europa. Värmeåtervinning och lågtemperaturvärmesystem visade sig båda ha större inverkan i kallare klimat. Lågtemperaturvärmesystem förbättrar värmefaktorn för värmepumpar, i synnerhet när uppvärmningsbehovet är stort i förhållande till varmvattenbehovet. Vid renovering av byggnader med vattenburna radiatorer kan konvertering till tilluftsradiatorer sänka framledningstemperaturen i värmesystemet. I svenska flerfamiljshus kan frånluftsvärmepump vara ett kostnadseffektivt komplement till fjärrvärme, medan från- och tilluftsventilation med värmeåtervinning är dyrare men mer sannolikt att ge en minskad primärenergianvändning. I ett systemperspektiv kan frånluftsventilation utan värmeåtervinning minska primärenergianvändningen i fjärrvärmeverket lika mycket som en frånluftsvärmepump, tack vare den lägre elanvändningen. / iNSPiRe
254

Méthodologie pour la conception optimisée des réseaux de chaleur et de froid urbains intégrés / Optimisation strategy for the district energy systems design

Apostolou, Matthildi 30 November 2018 (has links)
La thèse présente un modèle d’optimisation mathématique ainsi qu’une méthodologie d’étude pour la conception optimale de réseaux de chaleur et de froid flexibles et intégrant des technologies innovantes (les smart réseaux ou réseaux 4e génération). Dans ce modèle, différentes contraintes énergétiques, économiques et environnementales sont alors considérées. Le modèle considère des réseaux de chaud (ou de froid) à différents niveaux de température, ainsi que différents sites de production et demande d’énergie. Le tracé du réseau ainsi que la configuration de l’ensemble des systèmes de production sont obtenus en minimisant soit l'exergie totale consommée soit le coût total pour l’investissement et l’opération des systèmes. Le modèle mathématique développé est formulé en un problème MINLP multi-période. Les contraintes du modèle sont présentées dans plusieurs modèles imbriqués. Le premier modèle M1 est multi-période et inclut les contraintes d’échanges avec le réseau et un moyen de stockage thermique. Le deuxième modèle, appelé M2, contient l’ensemble du modèle M1 ainsi que des nouvelles contraintes permettant de dimensionner des pompes à chaleur à COP variable. Le troisième modèle M3 inclut le modèle M2 ainsi que de nouvelles contraintes pour le tracé géographique des réseaux et la prise en compte des flux d’électricité. Une méthodologie d’étude est aussi présentée, permettant, à l’aide du modèle M3 développé, de traiter des cas d’étude complexes et réalistes. La méthodologie propose une décomposition du problème selon trois étapes consécutives. Cette méthodologie est alors utilisée et illustrée pour un cas d’étude complexe : l’optimisation d’un nouveau quartier, considérant des PAC, un stockage de chaleur saisonnier et de la production PV. / This thesis presents a mathematical optimization model and a methodology for the optimal design of district heating and cooling networks. The various constraints in energy balances, costs and environmental criteria can be considered in order to propose structures of flexible and innovative networks.The model allows the consideration of heating (or cooling) networks at different temperature levels, as well as different production sites and heat demands. The network’s layout as well as the optimal architecture of the heat production systems are achieved by minimizing either the total exergy consumed or the total cost for the investment and operation of the systems.The developed mathematical model is formulated into a multi-period MINLP problem. The constraints of the model are presented in nested models. The first model M1 considers the multi-period aspect and includes the constraints related to the heat exchanges between production/demand streams with the network and a thermal storage. The second model, called M2, contains the entire model M1 as well as new constraints for sizing heat pumps with variable COP. The model M3 includes the model M2 as well as new constraints for the geographical layout of the networks and the consideration of electricity balance in the problem.A methodology is also presented making it possible, using the model M3, to deal with complex and realistic case studies. The methodology proposes a decomposition of the problem following three consecutive steps. This methodology is then used for the optimization of a new district, considering heat pumps, seasonal heat storage and PV production.
255

Teplárenské sítě / Piping systems for district heating

Malach, Tomáš January 2018 (has links)
In the first part of master thesis is presented general introduction to district heating system (DHS) and hydraulic calculation for DHS. The next part deals with analysis operation of DHS and the pressure diagram for certain time interval. Subsequently, the thermohydraulic characteristics for the hydraulic main branch (comparing manual calculation with software calculation) and also the selected thermal and hydraulic characteristics for the whole DHS are shown. The last part is focused on the determination of the amount of heat supplied based on the ultrasonic flowmeter and the temperature probes. Subsequently, the computer simulation is also carried out, aiming at approximating the real heat supply from heat source to solved thermal network in winter.
256

Posouzení kotle na odpadní teplo / Assessment of transfer line exchanger

Hradil, Lukáš January 2009 (has links)
This theses work is concerned with assessment of transfer line exchanger behind pusher furnace. First part is describing technical characteristic and parametres. The most important part of this theses is thermic calculation of the boiler. Last following part is concerned with suggestions of constructional modifications of heating surface for proper functioning of boiler. These modifications are demonstrated by scheme in the enclosure.
257

Zdroj na biomasu v Teplárně Brno - sever / Biomass Heating Power Plant Brno-nord

Saňka, Marek January 2014 (has links)
The master’s thesis topic is the feasibility study of new biomass source construction in power heating plant Brno-North. The first part is focused on historical and current conditions and future development of heat distributions networks and sources of Brno. The power heating plant operation Brno-North is described in more detail including the current heat scheme of operation and plan for the future development. Next chapters are focused on projection of new biomass source. At first, it is defined heat output, operation range and parameters of the new source based on the data of real needs after the heating network modernization. Afterward, selected conceptual variants of the new source are discussed in more detail and for each of the variants are performed heat balance calculation and assembled heat scheme of operation. At the same time it is processed warehouse management calculation and economic analysis of the project. The final chapter evaluates the technical and economic parameters of variants and recommends the most suitable variant of the project.
258

Konstruktion av en nedsänkt värmeväxlare för nyttjande av lågvärdig värme vid urladdning av bergrum / Construction of a submerged heat exchanger for the use of low-grade heat when discharging a rock storage

Öman, Sandra January 2020 (has links)
Behovet av att kunna lagra energi blir allt större och nödvändigare i takt med utvecklingen och användningen av de förnyelsebara energikällorna. Bergrumslagring är en beprövad metod som oftast används för att säsongslagra värme från fjärrvärme. Tidigare har ett examensarbete på PiteEnergi utförts med mål att undersöka om det är möjligt att lagra fjärrvärme från ett lågtempererat nät på Haraholmen i ett närliggande bergrum. Resultatet blev att det fanns goda förutsättningar men vid urladdning fanns en stor mängd energi fortfarande kvar i bergrummet. Detta arbete är en fortsättning på det, att undersöka om det är möjligt att nyttja även den lågvärdiga energin i bergrummet med en nedsänkt värmeväxlare. Den nedsänkta värmeväxlaren har i detta examensarbete konstruerats och resulterade i 3 mil långa stålrör, uppdelade i fem parallellkopplade värmeväxlare med ytterdiametern 89 mm.  Den nedsänkta värmeväxlaren som i detta projekt är konstruerad har en återbetalningstid på 10 år och en livslängd på 30 år. Vinsten av investeringen skulle efter 30 år vara ungefär 30 miljoner kronor. Ungefär 1 GWh mer än tidigare är möjligt att årligen ta ut med en nedsänkt värmeväxlare, jämfört med en klassisk som endast nyttjar den högvärdiga energin i bergrumsvattnet som är tillräckligt varmt att köra direkt ut på fjärrvärmenätet. / As the development and use of renewable energy sources grow, the need for energy storage is becoming increasingly important. Rock storage is a tried and tested method most commonly used to store seasonal heat from district heating. A previous degree project was carried out at PiteEnergi, with the aim of investigating whether it is possible to store district heating from a low-temperature grid at Haraholmen in an adjacent cavern. The conclusion was that there are good conditions for rock storage, but when discharging there were still a lot of energy left in the cavern. This degree project is a continuation of a previous work, to investigate the possibility of using a submerged heat exchanger to utilize even the low energy left in the underground caverns. The submerged heat exchanger has been designed in this thesis and resulted in 30 kilometre long steel pipes, divided into five parallel coupled heat exchangers with the outer diameter of 89 mm. The immersed heat exchanger constructed in this project has a payback time of 10 years and a life expectancy of 30 years. After 30 years, the profit from the investment would be about 30 million SEK. Compared to a classic heat exchanger, the submerged heat exchanger has the possibility of annually charging about 1 GWh more than before. This compared to a classic heat exchanger that only uses the high-quality energy from the water in the underground cavern that is hot enough to run directly to the district heating network.
259

Felsökning : En förstudie inom organisationsförändring hos Värmevärden i Nynäshamn AB

Schönning, MaiLi January 2021 (has links)
Dagens uppvärming av hus kan ske med fjärrvärme och bakom leveransen av fjärrvärme finns det oftast en anläggning med en panna och operatörer som ska säkerställa driften så att hushållen får möjlighettill uppvärming. Vid eventuella störningar i anläggningen är det viktigt att operatörerna får möjlighet att felsöka problemet och därmed säkerställa driften av pannan, vilket ställer krav på felsökningen som operatörerna utför. Det här examensarbetet var i samarbete med Värmevärden i Nynäshamn AB och utfördes från juli 2020 till januari 2021. Syftet med projektet var att undersöka om det gick att identifiera vilka områden företaget behövde arbeta med för att förbättra den mekaniska felsökningen. Målet var att presentera ett förbättringsförslagför att ge operatörerna bättre förutsättningar vid felsökning av anläggningen. Projektprocessen som användes var projektcirkeln med två iterativa faser. För att planera projektet användes ett Gantt-schema och metoderna som användes för att samla information från operatörerna var observationer, intervjuer och information från företagets interna dokumentation. Inledningsvis genomfördes en kontextundersökning som var utgångspunkten i det här projektet. Ostrukturerade intervjuer med operatörerna och informationssamling från företagets interna dokumentation visade att företaget har utvecklingspotential gällande felsökning, grundorsaksanalyser och ensamarbete. Utifrån den kunskapen inhämtades därefter lämplig teori som grundorsaksanalys, ensamarbete, inlärning och kompetensutveckling, människans handlingsbeteenden, avvikelser i verksamheten, ta fram en metodstandard samt incidentrapportering. Kunskapen bidrog med ökad förståelse kring situationen och en djupare förståelse för ämnena. Därefter utfördes en datainsamling med hjälp av åtta intervjuer som pågick under tre dagar samt treobservationer i samband med besöken för intervjuerna. Denna datainsamling låg till grund för beskrivning av nuläget. Observation användes för att se hur tavlan med daglig styrning nyttjades men även för att studera hur personalen hanterade ett oplanerat strömavbrott. Slutligen analyserades även ”flippkortstavlan” som fanns inne i kontrollrummet som har fasta arbetsuppgifter, fördelade på jämna och ojämnaveckor. En intervju genomfördes med underhållsledaren men personen var ensam och därför kunde svaret inte skrivas ut i rapporten, med hänsyn till anonymiteten. Utifrån ovanstående datainsamling behövdes ytterligare information och teori för att komplettera kunskapen där ämnena var framtidens operatörer, systematiskt arbetsmiljöarbete, säkerhet och risk och förbättringsarbete. Därefter genomfördes en analys av nuläget där den teoretiska referensramen kopplades ihop med nuläget, som förklarade vilken möjlighet till förändring som fanns inom respektive område. Resultatet bestod av områden som företaget har möjlighet att förbättra. Operatörernas situation och säkerhet vid ensamarbete behövde förbättras för att kunna skapa en tryggare arbetsmiljö, exempelvisgenom att utföra riskanalyser och förbättra säkerhetsutrustningen i anläggningen. För att genomföra en felsökning fanns det möjlighet att använda en checklista med korta och enkla frågor som togs fram underprojektet. En förklaring till varför grundorsaken var så pass viktig att genomföra och förslag på vem som är ansvarig för att en grundorsaksanalys utfördes förklarades i resultatet. Det föreslogs även att ta fram en handlingsplan för grundorsaksanalyserna för att kunna genomföra dessa. För att möjliggöra lärande av felsökning var det viktigt att ha ordentlig dokumentation. För att skapa en lärande organisation föreslogs det att företaget kunde använda en iterativ process samt att se de anställda till individer som har olika förutsättningar. Värmevärden i Nynäshamn borde även ta fram en handlingsplan för att uppnå organisatoriskt lärande men även möjliggöra kunskapsöverföring för operatörerna. Vid störningar var det viktigt att skapa kontinuitet för arbetsuppgifter inte ska falla mellan stolarna. För att möjliggöra hanteringenav avvikelser gavs det även förslag på hjälpmedel att använda sig av i processen, som iterativa processer, tavlor för att kunna överblicka arbetsuppgifterna och verktygstavlor kunde placeras ut i anläggningen. Företagets dokumentation hade förbättringspotential gällande vokabulär och hur termer användes där även flödesschemat vid händelser hade utvecklingspotential. Till sist lyftes även hur företaget kunde gör aför att möjliggöra bättre kontinuitet vid händelser som sträcker sig under en längre tid. Diskussionskapitlet syftade till att diskutera och besvara relevans, reflektion och slutsatser och till sists vara på projektets sex frågeställningar. Rekommendationerna poängterade vad som skulle förändras först och förslagen presenterades i en prioriteringslista. Punkterna baserades på operatörernas intervjuer och den teoretiska referensramen. Första förändringen som rekommenderades att genomföra var att undersöka och genomföra en riskanalys på ensamarbetet. Det rekommenderades även att gå igenom säkerhetsutrustningen i anläggningen och hantera tidsbristen genom att tidsinventera arbetsuppgifterna, även de oförutsedda händelserna för att se hur mycket tid som lades på dessa. I rekommendationen förklarades även hur en förändringsplan implementerades för att kunna realisera förändringar. Till sist handlade vidarearbete om punkter som hade uppmärksammats under projektet, där det fanns potential att göra en förändring men punkterna behövde undersökas ytterligare för att se hur förändringen skulle genomföras. / Today’s heating of houses can take place with district heating and behind the delivery of district heating is there are often a facility with a boiler and operators that will ensure heating of the households. In the event of disturbances of the plant it is important that the operators are given the opportunity to troubleshoot the problem and thereby ensure that the boiler and the plant is working, which places demands on the troubleshooting that the operators perform. This master thesis was a collaboration with Värmevärden in Nynäshamn AB and was conducted from July 2020 to January 2021. The purpose of this project was to investigate whether it is possible to identify which areas the company needed to work with to improve the mechanical troubleshooting. The goal was to present an improvement proposal to give the operators better conditions when troubleshooting the facility. The process of the project was the project circle with two iterative phases. A Gantt-chart was used to plan the project and the methods used to gather information from the operators were observations, interviews, and information from the company’s internal documentation. Initially in the project, a context study was conducted which was the starting point for this project. Unstructured interviews with the operators and information gathering from the company’s internal documentation showed that the company had a development potential regarding troubleshooting, root cause analysis and working alone. Based on that knowledge, useful theory was then obtained such as root cause analysis, solo work, learning and competence development, human action behaviours, deviation in the business, developing a method standard and reporting incidents. The knowledge contributed with and increased understanding for the situation and deeper understanding for the topics. Subsequently, a data collection was made with help of eight interviews for three days, as well as three observations in connection with the visits for the interviews. This data collection was the basis for describing the current situation. Observation was used to see how the board with daily control was used but also to study how the staff handled an unplanned power outage. Finally, the ”flip cardboard” that was inside the control room, which has fixed tasks even and uneven weeks, was also analysed. An interview was conducted with the maintenance manager, but the person was alone and therefore the answer could not be printed in the report with regard to anonymity. Based on the data collection, additional information and theory were needed to supplement the knowledge where the subjects were the operators of the future, systematic work environment work, safety and risk and improvement work. The current situation was then analysed with the help of the theoretical framework, which explained the possibility of change in each area. An analysis of the current situation was then performed where the theoretical framework was linked to the current situation. The result consisted of areas that the company had the opportunity to improve. The operators’ situation and safety in working alone needed to be improved to be able to create a safer work environment, for example by carrying out risk analyses and improving the safety equipment in the facility. To perform a troubleshooting, it was possible to use a checklist with short and simple questions that was provided during this project. An explanation of why the root cause was so important to perform and suggestions on who is responsible for a root cause analysis was given in the result. It was also proposed to develop an action plan for the root cause analyses in order to be able to implement them. To enable to learn from the troubleshooting, it was important to have proper documentation. To create a learning organisation, it was suggested that the company used an iterative process and to saw the employees as individuals who had different conditions. Värmevärden in Nynäshamn should also develop an action plan to achieve organisational learning but also enable knowledge transfer for the operators. In the event of disturbances, it was important to create continuity so that work tasks do not fall between the chairs. To enable the handling of deviations, suggestions was also given for aids to use in the process, such as iterative processes, boards to be able to overview the work tasks and tool boards can be placed in the facility. The company’s documentation had potential for improvement regarding vocabulary and how terms were used, where the flow charts for events also had development potential. Finally, it also highlighted what the company could do to enable better continuity in the event of events that extend for a longer period.  The discussion chapter aimed to discuss and answer relevance, reflection and conclusions and finally answer the project’s six questions. The recommendations were intended to point out what should be changed first, and the proposals was presented in a priority list. The areas were based on the operators’ interview and the theoretical framework of this project. The first change that was recommended to be implemented was to investigate and perform a risk analysis of the work done alone. It was also recommended to go through the safety equipment in the facility and manage the lack of time by time-inventorying the work tasks, including the unforeseen events to see how much time that was spent on these events. The recommendation also explained how a change plan should be implemented in order to be able to realise changes. Finally, the further work highlighted areas that had been noticed during the project, where there was potential to make a change but the areas needed to be investigated further to see how the change would be implemented.
260

Energikartläggning av förskola : Underlag för energieffektiviseringsåtgärder av byggnaden Metreven samt fördjupning avseende potential för uppfyllande av Boverkets krav gällande nära- nollenergibyggnad

Lehtonen, Joakim January 2020 (has links)
The Swedish residential sector consumes almost 39 % of Sweden’s final energy consumption. The European Union framework ”Clean Energy for all Europeans package” strives to promote a 32,5 % reduction as a result of energy efficiency measures. The Swedish legislation BBR regulates rules regarding new buildings, extensions and reconstruction of existing buildings. Excerpt 9 regards how energy is being used and determines the demands e.g. for a buildings primary energy use to be classified as a near zero energy building (NZEB). The energy use of a building, located in Västerås, Sweden, is being decided. Various energy efficiency packages are applied to a model in the simulation software IDA ICE. The results are compared with each other deciding the potential benefits of the energy efficiency measures. A substantial decrease of the energy consumption is detected, especially for the energy efficiency packages containing a geothermal heat pump (66 – 78 %). A life cycle cost analysis shows that the package containing a ventilation heat recovery system (FTX) combined with a geothermal heat pump is the optimal solution through an economical point a view. The solution yields a profit after 14 years. The analysis shows that all geothermal solutions, except a system consisting of a geothermal heat pump, FTX, energy efficient windows, rooftop insulation and a photovoltaic system, yields a profit during a 30-year investment period. None of the packages containing a district heat exchanger yield a profit. The simulation results show that by implementing any of the geothermal heat pump packages, the demands for classifying the building according to an NZE building are fulfilled. Regarding the district heating packages, only the package containing all the energy efficiency measures (energy efficient windows, rooftop insulation and PV) meets the demands to be classified as an NZE building. Regarding the environmental impact due to implementing the energy efficiency measures, the results show a reduced impact from applying the geothermal heat pump packages is equivalent to the energy consumption reductions. The results show that by implementing a district heating system, more than one additional energy efficiency measure must be applied to avoid an increased environmental impact. This thesis shows that implementing energy efficiency measures can decrease energy consumption and yield an economical profit to the existing building stock.