Vlastnosti exkrečně-sekrečních proteinů motolice Fascioloides magna. / Characterization of excretory-secretory proteins of liver fluke Fascioloides magna.

Beránková, Kateřina January 2011 (has links)
Fascioloides magna (the giant liver fluke) originated from North America, is known in the Czech Republic since 1930s. This pathogenic fluke invades mostly cervids, but livestock too. Excretory-secretory products (ES products) contain number of esential biomolecules which are produced by excretory and secretory system of the fluke. These molecules play key role in many biological process during the life cycle not only of fascioloid flukes (e.g. migration in the host tissues, immune evasion and digestion). Due to their antigenic properties they could be also used in immunodiagnostics. Excretory-secretory proteins from adult Fascioloides magna and comparative related species Fasciola hepatica were purified and separated by the basic biochemical methods (1D, 2D electrophoresis, ion-exchange chromatography) and their activity was confirmed by specific (fluorogenic peptide) and nonspecific (gelatine) substrates. By using the mass spectrometry methods (MALDI TOF/TOF), the most abundant peptidolytically active proteins from ES products of F. magna were identified as cathepsin L (FmCL). Recombinant analog of FmCL was expressed in Pichia pastoris expression system. The peptidolytic activity was again confirmed using the synthetic fluorogenic substrates; the specifity of recombinant FmCL active site was...
812

Immundiagnostische Charakterisierung der bovinen Protothekenmastitis

Rösler, Uwe 28 November 2001 (has links)
Die Protothekenmastitis des Rindes ist eine therapieresistente, weltweit vorkommende Infektionskrankheit. Das ätiologische Agens, die farblose Alge Prototheca (P.) zopfii, kommt ubiquitär in feuchten Habitaten vor und verursacht fakultativ akute bis chronische Entzündungen des Rindereuters. Es gibt Hinweise auf das Vorkommen eines speziellen, Mastitis-assoziierten Biotyps von P. zopfii, der sogenannten Variante II. Durch die oft zu beobachtende endemische Ausbreitung in Milchviehbeständen sowie durch die nachhaltige Therapieresistenz, welche oft zum wirtschaftlichen Totalverlust der betroffenen Milchkühe führt, stellen Protothekenmastitiden beim Rind ein großes ökonomisches Problem für den betroffenen Betrieb dar. Da bisher nur sehr beschränkte Erkenntnisse zur lokalen und systemischen Immunantwort sowie zur Erregerausscheidung im Verlaufe der Protothekenmastitis des Rindes vorlagen, wurden die verschiedenen klinischen Stadien dieser Infektion serologisch, kulturell sowie durch Bestimmung der Zahl der somatischen Zellen in der Milch charakterisiert. Zu diesem Zwecke wurden drei verschiedene ELISA-Systeme entwickelt, die anschließend auch auf ihren möglichen Einsatz bei der Diagnostik der Protothekenmastitis hin untersucht wurden. Dies geschah in einem hochgradig an Protothekenmastitis erkrankten Milchviehbestand. Darüber hinaus wurden verschiedene Isolate von P. zopfii auxanographisch, biochemisch, serologisch und genetisch untersucht, um eine Differenzierung innerhalb der Algenspezies P. zopfii vornehmen zu können. Anhand der auxanographischen, biochemischen, serologischen und genetischen Untersuchungen war eine eindeutige Differenzierung von drei verschiedenen Bio-, Sero- und Genotypen innerhalb der Algenspezies P. zopfii möglich. Alle untersuchten Mastitisisolate konnten eindeutig der Variante II von P. zopfii zugeordnet werden, womit dieser Variante eine besondere epidemiologische Bedeutung bei der Entstehung der Protothekenmastitis des Rindes zu zukommen scheint. Die Untersuchungen dieser Arbeit zeigen, dass akut infizierte Tiere sowohl die höchsten Antikörperaktivitäten an IgG im Blutserum sowie an IgA und IgG1 im Milchserum als auch die höchsten Gehalte an somatischen Zellen in der Milch aufweisen. Chronisch infizierte Milchkühe weisen zum Teil sehr hohe Antikörperaktivitäten in der Milch auf und unterschieden sich nicht signifikant von akut infizierten Tieren. Demgegenüber weisen diese chronisch infizierten Tiere signifikant höhere IgG-Aktivitäten im Blutserum sowie IgA- und IgG1-Aktivitäten in der Milch auf als nicht infizierte Tiere. Somit ist eine eindeutige Differenzierung zwischen infizierten und nichtinfizierten Kühen möglich. Die ELISAs zum Nachweis von spezifischem IgA und IgG1 im Milchserum erwiesen sich als besonders geeignet, um infizierte Kühe zu identifizieren. Beide serologischen Testsysteme wiesen Sensitivitäten von 96,3 % für IgA sowie 92,6 % für IgG1 und Spezifitäten von 94,4 % (IgA) und 96,3 % (IgG1) auf. Demgegenüber wies der ELISA zum Nachweis von spezifischem IgG im Blutserum bei einer Spezifität von 100 % nur eine Sensitivität von 81,5 % auf. Die sehr gute Reproduzierbarkeit der Tests wurde durch Intra-Assay-Variationen von 6,08 % für den Nachweis von IgA im Milchserum und 7,20 % für IgG1 sowie durch die geringe Inter-Assay-Variation von 6,32 % (IgA) und 9,74 % (IgG1) belegt. Der Einsatz dieser Testsysteme bei der Sanierung eines hochgradig mit P. zopfii infizierten Milchviehbestandes zeigte, dass die serologische Diagnostik dem bisher gebräuchlichen kulturellen Erregernachweis bei der Identifikation intermittierender Erregerausscheider überlegen ist. Es wurde deutlich, dass 70,5% der infizierten Tiere die Erreger über einen Zeitraum von 12 Monaten permanent ausschieden und mindestens weitere 4,9 %, wahrscheinlich jedoch wesentlich mehr, dieser infizierten Tiere intermittierende Erregerausscheider waren. Somit scheint der serologische Erregernachweis für die Diagnostik der Protothekenmastitis des Rindes besser geeignet zu sein als die kulturelle Diagnostik. Dabei wurde die höchste Sensitivität durch die Kombination des Nachweises von spezifischem IgA und IgG1 im Milchserum erzielt. / Protothecosis is a severe, often endemic mastitis in cattle caused by colorless algae of the genus Prototheca. Only little and insufficient knowledge about the organism itself, and the host immune response to this infection existed. Therefore, the aim of this thesis was to characterize the local and systemic immune response and the possible elimination or persistence of the pathogen in the host. To gain more information on the specific immune response, different clinical stages of infection were characterized serologically, culturally, and by determination of the number of the somatic cells in milk. Three different ELISA systems were developed, which were also examined for their diagnostic application potential. For the investigations, a dairy herd highly infected with Prototheca zopfii and severe clinical manifestation of protothecal mastitis was used. The ELISA was evaluated using serum and whey from animals with different clinical stages of infection. As antibody isotypes, IgG in serum, and IgA and IgG1 in whey were used. In addition, different isolates of P. zopfii were biochemically, serologically, and genetically examined in order to allow a differentiation of individual isolates within the species P. zopfii. The biochemical, serological and genetic investigations allowed a clear differentiation of the three known Variants of P. zopfii. All examined mastitis isolates could be assigned to variant II of P. zopfii. Therefore, it can be concluded that this variant has a particular epidemiological significance in the etiology of bovine protothecal mastitis. The serological investigations showed high antibody activities during acute and chronic stage of infection. The antibody activity was low in chronically infected, but presently cultural negative animals and also in uninfected animals. A strong correlation was observed between whey IgA and whey IgG1 antibody activity and the count of somatic cells in milk. Whereas, only a weak correlation exists to the number of algae cells excreted with the milk. A sensitivity of 96 % and a specificity of 94 % were calculated for the ELISA based on IgA levels. The ELISA for detection of specific IgG1 in whey shows a sensitivity of 92,6 % and a specificity of 96,3 %. Intra-assay and interassay variations were calculated to be at 6.08 % and 6.32 %, respectively. Based on these data, these ELISAs are suitable for discrimination between infected and uninfected animals, and might therefore be used for the screening of affected herds. When used in the remediation of a high-grade infected dairy herd the serological showed clear advantages in the identification of intermittent shedders. By culturing of Prototheca from milk, it was shown that 70.5% of the infected animals were permanent shedders, whereas 4.9 % were intermittent shedders. Since intermittent shedders could be clearly identified serologically, but might not be recognized by culturing, it can be assumed that serological diagnostics is more suitable for the identification of inapparently infected, intermittent shedders.
813

Comparison of a Novel Cell-based Reporter Assay and a Competitive Binding ELISA for the Detection of Thyrotropin-Receptor (TSHR) Autoantibodies (TRAb) in Graves’ Disease Patients

Hata, Misako 16 April 2010 (has links)
No description available.
814

Entwicklung immunchemischer Methoden zur Spurenanalytik der Sprengstoffe Nitropenta und Trinitrotoluol

Hesse, Almut 04 May 2017 (has links)
Der Sprengstoff PETN ist äußerst schwer zu detektieren. Ein verbesserter anti-PETN-Antikörper wurde durch Anwendung des Bioisosterie-Konzepts entwickelt. Diese polyklonalen IgGs sind sehr selektiv und sensitiv. Die Nachweisgrenze des ELISAs beträgt 0,15 µg/L. Der Messbereich des Immunoassays liegt zwischen 1 und 1000 µg/L. Die Antikörper sind recht pH-stabil als auch robust gegen Lösungsmittelzusätze. Für die Umweltanalytik von TNT wurde eine HPLC-kompatible Affinitätssäule mit porösem Glas als Trägermaterial hergestellt. Um die anti-TNT-Antikörper selektiv aus den TNT-Seren zu isolieren, wurde eine Trennung an einer Dinitrophenyl-Affinitätssäule durchgeführt. Zur Optimierung der Kopplungsmethode wurden orangefarbene Dabsyl-Proteine synthetisiert und auf der Oberfläche gebunden. Die Färbung wurde als Indikator für die Ligandendichte verwendet. Wegen der hohen Affinitätskonstanten der anti-TNT-IgGs lässt sich TNT nicht reversibel von der TNT-Affinitätssäule eluieren. Daher wurde eine neuartige Elutionsmethode entwickelt, die thermische Online-Elution. Die maximale Kapazität einer TNT- Affinitätssäule betrug 650 ng TNT bzw. 10 µg/mL Säulenvolumen. Um die Ligandendichte der TNT-Affinitätssäulen zu bestimmen, wurde ein neues Verfahren entwickelt, da die spektroskopischen Proteinbestimmungsmethoden nicht geeignet waren. Zur Proteinbestimmung wurde eine HPLC-Trennung der Aminosäuren Tyr und Phe ohne vorherige Derivatisierung entwickelt. Die Proteinhydrolysezeit wurde durch Einsatz einer Mikrowelle von 22 h auf 30 min verkürzt. Zur internen Kalibrierung wurden HTyr und FPhe verwendet. Die Nachweisgrenze bei 215 nm ist sowohl für Tyr als auch für Phe 0,05 µM (~ 10 µg/L). Dieses neue Verfahren, das als Aromatische Aminosäureanalyse (AAAA) bezeichnet werden kann, wurde zur Proteinbestimmung von homogenen Proben mit NIST-BSA validiert, wobei die Nachweisgrenze für Proteine 16 mg/L (~ 300 ng BSA) ist. Die relative Standardabweichung incl. der Hydrolysestufe beträgt 5%. / The explosive Pentaerythritol tetranitrate (PETN) is extremely difficult to detect. An improved antibody against PETN was developed by using the bioisosteric concept. These polyclonal antibodies are highly selective and sensitive. The limit of detection (LOD) of the ELISA was determined to be 0.15 µg/L. The dynamic range of the assay was found to be between 1 and 1000 µg/L. The antibodies are sufficiently pH-stable and resistant to solvent additives. An HPLC-compatible TNT-affinity column with porous glass as support material was prepared for the environmental analysis. In order to isolate the anti-TNT antibodies of the TNT sera a separation was carried out on a dinitrophenyl-affinity column. To optimize the immobilization method, orange-coloured dabsyl proteins were synthesized and bound to the surface. The colour intensity was found to be an indicator for the immobilization rate. In consequence of the high affinity constants of the anti-TNT antibodies, TNT can''t elute by a typical acidic elution step. Therefore, a novel separation approach, the thermal online-elution was developed. The maximum capacity of an affinity column was 650 ng TNT or 10 µg/mL of column volume. To quantify the immobilization rate of proteins, a new method has been developed, because the usual protein determination methods were unsuitable. Therefore an HPLC separation method of Tyr and Phe was developed without prior derivatization. Two internal standard compounds, HTyr and FPhe, were used for calibration. The LOD was estimated to be 0.05 µM (~ 10 µg/L) for Tyr and Phe at 215 nm. The protein hydrolysis time was reduced from 22 h to 30 min using microwave technique. This procedure, that was termed aromatic amino acid analysis (AAAA), has been validated for protein determination of homogeneous samples with NIST-BSA. The LOD for proteins was calculated to be below 16 mg/L (~ 300 ng BSA absolute). The relative standard deviation, including the hydrolysis step, is 5%.
815

Entwicklung und Validierung eines Enzyme-linked Immunosorbent Assays (ELISA) für die Quantifizierung von Carbamazepin in Abwasser, Oberflächenwasser und Trinkwasser

Bahlmann, Arnold 17 April 2013 (has links)
Ein kompetitiver ELISA (Enzyme-linked Immunosorbent Assay) für den Nachweis von Carbamazepin (CBZ) mit einer Bestimmungsgrenze von ca. 30 ng/L wurde entwickelt und validiert. Dieser in Gewässern häufig auftretende anthropogene Marker wurde anschließend in einer Vielzahl an Proben aus Abwässern, Oberflächengewässern und Trinkwässern nachgewiesen. Der ELISA zeigte eine exzellente Präzision und erbrachte in allen Matrizes geringfügig höhere Analysenergebnisse als die Referenzmethode HPLC-MS/MS. Die beständige Überbestimmung der CBZ-Konzentration in Höhe von ca. 7 % konnte auf die Präsenz von Cetirizin und geringen Mengen des persistenten Metaboliten 10,11 Epoxy¬carbamazepin (EP-CBZ) zurückgeführt werden. Die Bindungseigenschaften des verwendeten Antikörpers wurden anhand der Kreuz¬reaktivi¬täten von 37 Substanzen eingehend untersucht. Nach Kopplung von Flüssig¬chromato¬graphie und ELISA konnte das strukturell nicht mit CBZ verwandte Anti¬histaminikum Cetirizin als Kreuzreaktand identifiziert werden. Der störende Einfluss dieses Kreuz¬reaktanden auf den CBZ-ELISA konnte nach einer Änderung des pH-Wertes im Proben¬puffer minimiert werden. Die pH-abhängige Selektivitätssteuerung ermöglichte überdies die Entwicklung eines Dual-Analyt-Immunoassays für die parallele Bestimmung von CBZ und Cetirizin. Darüber hinaus wurden die Metaboliten EP-CBZ, DiOH-CBZ, 2-OH-CBZ, 3-OH-CBZ und 10 OH-CBZ in Abwasser, Oberflächenwasser und Trinkwasser quantifiziert. DiOH-CBZ erwies sich als ähnlich persistent wie CBZ und wurde in besonders hohen Konzentrationen gefunden. Außerdem wurden mehrere weitere bislang nicht identifizierte Abbauprodukte von CBZ gefunden. Da weder Probenvorbereitung noch Probenanreicherung erforderlich sind, ist der Test schnell und kostengünstig durchführbar. Die für den Test nötigen Probenvolumen sind mit weniger als 1 mL sehr gering. Diese Eigenschaften erlauben ein Hochdurchsatzscreening und machen die Methode interessant für den Einsatz im Gewässermonitoring. / A competitive ELISA (enzyme-linked immunosorbent assay) for the quantitation of carbamazepine (CBZ) was developed and validated. A limit of quantitation (LOQ) of ca. 30 ng/L allowed for the quantitation of CBZ in many samples from wastewater, surface water and drinking water. The method was found to be excellently precise, but it displayed slightly higher results than obtained by the reference method liquid chromatography-tandem mass spectrometry (LC-MS/MS). The nearly constant overestimation of 7 % could be attributed to the presence of small amounts of cetirizine and the persistent metabolite 10,11 epoxy¬carbamazepine (EP-CBZ). The binding properties of the antibody were studied by determining the cross-reactivities of 37 compounds. Hyphenating liquid chromatography to ELISA led to the discovery of the cross-reactive antihistamine cetirizine that shares no obvious structural similarity with CBZ. The bias caused by cetirizine was eliminated by changing the pH value of the sample buffer. Moreover, the antibody’s pH-dependent selectivity enabled a dual-analyte immunoassay for the parallel determination of CBZ and cetirizine. Furthermore, the metabolites EP-CBZ, DiOH-CBZ, 2-OH-CBZ, 3-OH-CBZ and 10-OH-CBZ were quantified in wastewater, surface water and drinking water. DiOH-CBZ showed the highest concentrations of all analaytes investigated and was found to be equally persistent as CBZ. In addition, several further degradation products of CBZ were found that could not be identified. The ELISA allowed the detection of diurnal and seasonal fluctuations of analyte concentrations in wastewater and surface water. The anthropogenic marker CBZ enabled to trace wastewater from the source to the receiving waters. Since neither sample pretreatment nor enrichment is necessary, the method is very fast and cost-effective. Only a small sample volume (less than 1 mL) is needed making this ELISA an appropriate high-throughput screening tool for environmental monitoring.
816

Immunochemical and chromatographic methods for two anthropogenic markers of contamination in surface waters

Carvalho, Jose Joao 08 December 2011 (has links)
Koffein (1,3,7-Trimethylxanthin) und Coprostanol (5beta-cholestan-3beta-ol) wurden im Berliner Oberflächenwasser nachgewiesen. Ihre Konzentrationen korrelierten mit dem Verunreinigungsgrad der Proben, was nahelegt, dass sie sich als Marker für menschliche Aktivität eignen. Bemerkenswerterweise wurde Koffein in jeder einzelnen Oberflächenwasserprobe oberhalb der Bestimmungsgrenze von 0,025 µg/L gefunden. Um Oberflächenwasserproben in größeren Serien zu untersuchen, war die Entwicklung zweier neuer Methoden erforderlich: ein Immunoassay, basierend auf einem monoklonalen Antikörper für Koffein und eine dispersive flüssig-flüssig Mikroextraktionsmethode (DLLME), gefolgt von Flüssigkeitschromatographie gekoppelt mit Tandem-Massenspektrometrie (LC-MS/MS) für Coprostanol. Der entwickelte Koffein-Immunoassay zeigt die beste je erhaltene Nachweisgrenze für Koffein (0,001 µg/L), erlaubt Hochdurchsatz-Analysen und erfordert keine Probenvorbereitung. Der Assay wurde auch erfolgreich für die Messung von Koffein in Getränken, Haarwaschmitteln, Koffeintabletten und menschlichem Speichel angewendet. Antikörper gegen Coprostanol sind nicht kommerziell erhältlich. Eine neue Strategie Anti-Coprostanol-Antikörper zu generieren wurde erarbeitet, die eine analoge Verbindung – Isolithocholsäure (ILA) – als Hapten verwendet, mit der eine Gruppe von Mäusen immunisiert wurde. Ein polyklonales Anti-ILA-Serum wurde produziert, welches Coprostanol bindet, aber die niedrige Affinität erlaubte nicht den Aufbau eines Immunoassays, der die Messung von Umweltkonzentrationen des Anayten (im Bereich ng/L) zulässt. Spezifische Anti-ILA-Immunglobuline G wurden auch in den Faeces der Mäuse gefunden. Coprostanol wurde in den Wasserproben durch die Verwendung einer neuentwickelten LC-MS/MS-Methode unter APCI-Ionisation (atmospheric pressure chemical ionisation) gemessen. Konzentrationen oberhalb von 0,1 µg/L wurden nach Voranreicherung der Probe mittels DLLME bestimmt. / Caffeine (1,3,7-trimethylxanthine) and coprostanol (5beta-cholestan-3beta-ol) were detected in samples of Berlin’s surface water. Their concentrations correlated with the contamination status of the samples, suggesting their usefulness as markers of human activity. Remarkably, caffeine concentrations were always well above the limit of quantitation of 0.025 µg/L. In order to screen surface water samples in larger series, the development of two novel methods was required: a monoclonal antibody-based immunoassay for caffeine and a dispersive liquid-liquid microextraction (DLLME) method, followed by liquid chromatography tandem mass spectrometry (LC-MS/MS) for coprostanol. The caffeine immunoassay developed shows the best analytical limit of detection (LOD) obtained so far for caffeine (0.001 µg/L), allows high-throughput analysis, and does not require sample pre-treatment. The assay was also successfully employed to measure caffeine in beverages, shampoos, caffeine tab-lets, and human saliva. Antibodies to coprostanol are not commercially available. A new strategy to generate anti-coprostanol antibodies was elaborated using an analogous com-pound as hapten – isolithocholic acid (ILA) – and immunizing a group of mice. A polyclonal anti-ILA serum was produced, which binds coprostanol but the low affinity did not permit setting up an immunoassay to measure environmental concentrations of the analyte (in the range of ng/L). Specific anti-ILA immunoglobulin G were also found in the faeces of the immunized mice. Coprostanol was quantified in the water samples using a newly developed LC-MS/MS method using atmospheric pressure chemical ionisation (APCI). Concentrations above 0.1 µg/L were determined after sample preconcentration using DLLME. This extraction method also proved to be successful for enrichment of coprostanol-related compounds such as cholesterol, cholestanol, cholestanone, ergosterol, and stigmasterol.
817

Développement d’outils analytiques pour la détection de biomolécules directement dans des fluides sanguins

Breault-Turcot, Julien 09 1900 (has links)
Cette thèse porte sur le développement de biocapteurs basés sur la technique de résonance des plasmons de surface (SPR) pour effectuer des analyses directement dans un fluide sanguin n’ayant subi aucune purification ou dilution. L’ensemble des biocapteurs discutés exploiteront un instrument SPR portable développé dans le groupe du professeur Masson. Le premier volet de la thèse portera sur le processus d’interférence lié à l’adsorption non spécifique du sérum à la surface du capteur. L’analyse des biomolécules adsorbées sera effectuée en combinant la SPR à la spectrométrie de masse. Les informations obtenues seront exploitées pour la construction de biocapteurs adaptés à l’analyse en milieu sanguin. Un premier biocapteur développé ciblera la protéine antigène prostatique spécifique (APS) contenue dans le sérum servant de biomarqueur pour dépister le cancer de la prostate. Pour détecter les faibles concentrations de cette protéine directement dans le sérum, un matériel plasmonique microstructuré sera utilisé pour amplifier les signaux obtenus et sera recouvert d’une monocouche peptidique minimisant l’adsorption non spécifique du sérum. L’instrument SPR aura été adapté pour permettre également la détection simultanée de fluorescence. Un test ELISA sera ainsi effectué en parallèle du test SPR. Chacune des techniques fournira un contrôle pour la deuxième, tout en permettant de détecter le biomarqueur au niveau requis pour dépister la maladie. La combinaison des deux méthodes permettra aussi d’élargir la gamme dynamique du test de dépistage. Pour terminer, l’instrument SPR portable sera utilisé dans le cadre de détection de petites biomolécules ayant un potentiel thérapeutique directement dans un échantillon de sang. Des peptides ayant une activité anti-athérosclérotique pourront ainsi être détectés à même un échantillon de sang ni purifié ni dilué, et ce à des concentrations de l’ordre du micromolaire. Une modification de la microfluidique via l’introduction d’une membrane poreuse au cœur de celle-ci sera la clé permettant d’effectuer de telles analyses. La présente thèse met de l’avant de nouvelles stratégies et des modifications instrumentales permettant d’analyser des protéines et des petites molécules directement dans un échantillon non purifié de sérum ou de sang. Les modifications apportées au système fluidique, à l’instrument SPR et au niveau du biocapteur employé permettront d’effectuer des biodétections dans des matrices aussi complexes que les fluides sanguins. Les présents travaux mettent en lumière la capacité d’un instrument SPR/fluorescence portable à faire en 12 minutes la biodétection d’un marqueur du cancer de la prostate directement dans un échantillon de sérum. Finalement, on rapporte ici un des premiers articles où un biocapteur SPR est utilisé à même un échantillon de sang non-purifié pour faire des biodétections. / This thesis discusses the development of surface plasmon resonnance (SPR) biosensors to perform detection directly on unpurified and undiluted blood based fluids such as serum or blood. Every biosensor discussed in the following chapters rely on a home-built portable SPR device developed in Professor Masson’s research laboratories. Non-specific adsorption, which greatly hinders biosensing in crude fluids, will be the first topic of the thesis. Serum adsorption was performed on the SPR sensor surface and then characterized by SPR and mass spectrometry. This study provided useful information for biosensing directly in blood-based fluids. It also provided a better fundamental understanding of the nonspecific adsorption process on surfaces. The first biosensor was developed to detect prostate specific antigen (PSA), a protein normally contained in serum, which is a known biomarker for prostate cancer. In order to detect low concentrations of this protein directly in serum, a microstructured gold film was used to amplify the signal generated by the binding event on the biosensor. A peptide monolayer covered the metallic surface of the sensor to reduce non-specific protein adsorption. The SPR portable instrument was modified to simultaneous detect fluorescence in order to perform a SPR and ELISA test in a single instrumental platform. Each technique provided a control for the other for detection of the prostate cancer biomarker at concentration levels required for the screening of the disease. The SPR and ELISA combination also extended the dynamic range of the biosensing assay. Finally, the portable SPR device was used to detect small biomolecules with potential therapeutic activity directly in a sample of blood. Peptides with an anti-atherosclerotic activity were thus detected in an unpurified and undiluted blood sample at micromolar concentration. The addition of a porous membrane to the microfluidic used for the biosensing assay facilitated the successful detection of these molecules in whole blood. The present thesis describes novel strategies and instrumental modifications to unlock the possibility of performing biosensing directly on unpurified and undiluted blood-based fluids. Modifications of the fluidic system, the SPR instrument and biosensor used will allow detection in fluids with high complexity such as serum or blood. The work described herein reports a prostate cancer screening assay performed in 12 minutes directly in serum using a portable SPR/fluorescence instrument. Finally, this thesis reports one of the first scientific papers where a SPR biosensor is used to perform analysis directly in blood.
818

"Diagnóstico da doença de Chagas em bancos de sangue: linfoproliferação, detecção de anticorpos e estudo epidemiológico em indivíduos com provas sorológicas inconclusivas" / Diagnostic of Chagas disease in blood banks: lymphoproliferation, antibodies detection and epidemiological data in individuals with inconclusive serology

Yamamoto, Celia Regina Furucho 27 March 2006 (has links)
O objetivo deste estudo foi avaliar a contribuição de linfoproliferação (1 parâmetro) em associação a provas sorológicas de alto desempenho (4 parâmetros), estudo epidemiológico (1) e parasitológico (1) em indivíduos com sorologia convencional inconclusiva para a doença de Chagas. Mostramos que o diagnóstico de doença de Chagas é provável quando 3 ou mais desses parâmetros são positivos em 7 (15/73). A combinação: TESA-blot e linfoproliferação positivos revelou-se útil diante de antecedentes epidemiológicos positivos / This study aims to evaluate the contribution of lymphoproliferation (1 parameter) in association with high performance serological tests (4), epidemiological data (1) and parasitological tests (1) for Chagas disease in patients with inconclusive conventional serological tests. We showed that this diagnosis is probable in individuals presenting > three positive of these 7 parameters (15 of 73 individuals). The combination of TESA-blot, lymphoproliferation was useful when epidemiological data were positive
819

"Resposta imune humoral na malária humana: quantidade e qualidade de anticorpos anti-Plasmodium falciparum" / Humoral immune response in human malaria : quantity and quality of anti-Plasmodium falciparum antibodies

Leoratti, Fabiana Maria de Souza 24 August 2004 (has links)
Neste estudo avaliamos a resposta imune humoral de indivíduos naturalmente expostos à malária em áreas endêmicas no Brasil. Os anticorpos IgG, IgG1, IgG2, IgG3, IgG4, IgM, IgE e IgA anti-formas eritrocitárias de Plasmodium falciparum foram determinadas por ELISA. Anticorpos IgG, IgG1, IgG2 de alta avidez e IgG3 de baixa avidez predominaram nos indivíduos sem complicações de malária ou assintomáticos, enquanto anticorpos IgG4, IgE e IgM predominaram nos indivíduos com complicações clínicas por malária. Os resultados mostram que mesmo em regiões com transmissão instável de malária pode ser observado o desenvolvimento de imunidade protetora quando anticorpos apropriados são produzidos / In this study, we have evaluated the humoral immune response of individuals naturally exposed to malaria living in endemic areas of Brazil. We determined IgG, IgG1, IgG2, IgG3, IgG4, IgM, IgE and IgA antibodies against Plasmodium falciparum blood stages by ELISA. We observed that the level of high avidity IgG, IgG1 and IgG2 and low avidity IgG3 antibodies were higher in asymptomatic individuals or with uncomplicated malaria, while IgG4, IgE and IgM antibodies were higher in individuals with complicated malaria. Taken together the results showed that even in unstable malaria regions it can be observed the development of protective immunity against malaria when appropriate antibodies are produced
820

Caracterització dels receptors de l'activador tissular del plasminogen (tPA) en càncer de pàncrees

Roda Noguera, Oriol 30 May 2006 (has links)
El càncer de pàncrees és altament agressiu i representa la cinquena causa de mort al mon occidental. Anteriorment, en el nostre laboratori, vam identificar que el receptor tissular del plasminogen (tPA) hi està sobre-expressat i juga un paper important el la progressió tumoral. En la present tesi hem profunditzat en l'estudi del mecanisme molecular de tPA i seus receptors en aquest càncer. En primer lloc hem caracteritzat en detall la interacció de tPA amb Annexina A2 (principal receptor de tPA en endoteli i altament expressada en pàncrees) demostrant que les dades publicades sobre la seqüència responsable de la interacció no eren correctes. A més a més hem caracteritzat les proteïnes de lisats cel·lulars pancreàtics que interaccionen amb tPA mitjançant un assaig pull down i posterior anàlisi proteòmic. de tot identificant un conjunt de possibles lligands de tPA. D'entre aquests hem seleccionat galectina 1, una lectina que mai s'ha descrit que interaccioni amb tPA, per realitzar la caracterització bioquímica i funcional del seu paper com a nou lligand de tPA en càncer de pàncrees. / Pancreatic cancer is a highly aggressive disease and represents the fifth cause of death in occidental world. Our laboratory has previously reported tissue type plasminogen activator (tPA) over expression in this cancer and its role in tumoral progression. During the present thesis we have studied tPA and its molecular mechanism through its receptors in this tumor.We have first characterized tPA interaction with annexin A2 (its main receptor in endothelium and highly expressed in pancreas). Our results showed that published data about the sequence responsible of this interaction was not correct. We have also identified a set of new putative tPA receptors in pancreatic cell lisates using a pull down assay and proteomic analysis. One of the proteins identified was galectin 1, a lectin with not know relation with tPA. We performed a biochemical and functional characterization of the interaction between these two proteins in pancreatic cancer.