Energianalys av byggnad i industriell miljö : Energikartläggning med effektiviseringsförslag till byggnad innehå̊llande betningsprocess hos Ovako Hofors AB

Broström, Simon January 2015 (has links)
Världen står inför stora utmaningar där energibehovet ständigt ökar i takt med den globala ekonomin. Något de flesta människor idag känner till är kopplingen mellan energianvändning och negativ påverkan av miljö samt klimat. Sveriges industrier står inför stora utmaningar med ständigt växande global marknad. Följder blir tuffare konkurrenssituation för många företag. Konkurrenssituationen medför att företag flyttar sin verksamhet till länder med lägre produktionskostnader. Kostnader vilka i Sverige har ökat väldigt mycket de senaste decennierna. För att stoppa utflyttning av industriverksamhet krävs stora effektiviseringar i industriföretags energianvändning och förändring av attityd gentemot energianvändning. Studien vilken ligger till grund för rapporten utfördes med energikartläggning av en lokal hos ståltillverkaren Ovako Sweden AB i Hofors. Lokalen där energikartläggningen utförts innehåller en process kallad betning. Kartläggningen grundas på data erhållna av ÅF, vilka även har varit samarbetspartners i studien. Väldigt stora mängder energi används i lokalen, närmare bestämt 14 000 MWh. Störst andel energi går till produktionsprocesser i form av ånga och elektricitet. Ånganvändning står för 8 500 MWh medan elektricitetsanvändning uppgår till 4 500 GWh. För ånga kan kostnadsminskning med 60 % implementeras. Elektricitetskostnader kan med föreslagna metoder minskas med uppskattningsvis 14 %. För uppvärmning av lokalen beräknades användningen uppgå till 2 500 MWh. Användning av uppvärmningsenergi kan minskas drastiskt då byggnaden är väldigt dåligt isolerad och använder mycket energi till uppvärmning. Vid införande av samtliga föreslagna åtgärder för uppvärmning sparas totalt 95 % av uppvärmningskostnader
12

Energieffektivisering av byggnad M7 i Umedalen : Energikartläggning med förslag till energieffektiviserande åtgärder ur en ekonomisk synvinkel

Gåsste, Filip January 2016 (has links)
Bostäder och service står för 40 % av Sveriges energianvändning varav hushåll och lokaler står för 90 % av dessa. Det har beslutats i riksdagen att Sveriges energianvändning ska minska med 20 % fram till år 2020 och med 50 % till år 2050. Det finns stora vinster att göra energieffektivisering av byggnader, dels energi-, komfort- och kostnadsmässigt. Syftet med arbetet är att föreslå kostnadseffektiva energibesparande åtgärder. En energikartläggning har gjorts i byggnad M7 som tillhör det gamla sjukhusområdet på Umedalen i Umeå. M7 förvaltas av Balticgruppen som förvärvade byggnaden år 1987. Enligt uppgifter från energideklarationen så är energiprestandan 136 kWh/m2 och år. Enligt beräkningarna ger åtgärdspaketet en minskning av energianvändningen med 66 % till en energiprestanda på 46 kWh/m2 och år. Återbetalningen för åtgärdspaketet är ca 8,5 år. De enskilda åtgärderna som är mest kostnadseffektiva är att byta ut de gamla roterande ventilationsvärmeväxlarna mot nya och optimera styrningen av ventilationen i de två aggregaten, där de sistnämnda åtgärderna har en återbetalningsperiod på 3 och 7 dagar. / In Sweden, housing and services use about 40 % of all energy in which households and other premises stand for 90 % of these. The Parliament has decided that energy consumption must be reduced by 20 % to year 2020 and by 50 % to year 2050. Due to energy efficiency there are great savings to be found in costs, indoor climate and energy. The purpose has been to recommend cost efficient measures to lower the energy consumption. An energy survey has been made in a building, M7, located in Umedalen, Umeå belonging to Balticgruppen AB. The energy performance is 136 kWh/m2*year according to the energy declaration. The calculations of the energy measures result in a drop of energy usage by 66 % to an energy performance of 46 kWh/m2*year and a payback period of 8,5 years. The most cost efficient measures are made in the ventilation with the lowest payback period of only 3 days.
13

Energianalys och förbättringsåtgärder : Axel Dahlströms Torg 3

Carlander, Nathalie, Vagiström, Sara January 2016 (has links)
För att få en tydlig bild av energiflöden i byggnaden Axel Dahlströms torg 3 utfördes en energianalys på byggnaden. Den syftade till att identifiera hur energi tillförs samt används eller bortförs byggnaden, vilket genomfördes genom balansberäkningar angående energiflöden. På så vis möjliggjordes en diskussion kring åtgärder för att energieffektivisera byggnaden. Projektet genomfördes till stor del med hjälp av antaganden baserade på litteratur, inventering av byggnad samt bestämmelser inom branschen. Eftersom balansen i slutändan skulle gå jämnt upp (tillförd energi och bortförd/använd energi ska vara lika stora) kunde resultatet till stor del kontrolleras genom att iaktta skillnaden mellan tillfört och bortfört var. I rapporten uppgick denna skillnad till ca 5 %, vilket bestämdes vara acceptabelt för rapportens ändamål. Balansen visade då att byggnadens totala årsenergibehov var 205 kWh/m2 varav 78 kWh/m2 var el. Då balansen fastställts som korrekt undersöktes en rad olika åtgärder. Dessa har samlats i rapporten till ett åtgärdspaket för effektivare energianvändning och ett bättre inneklimat. Åtgärderna behandlar system kring ventilation, belysning och värme. I den mån möjligt har eldrivet konverterats till vattenburet, då fjärrvärme föredras till uppvärmning framför el. Med presenterat åtgärdspaket beräknades byggnadens nya årsenergibehov till 150 kWh/m2. Av detta var 56 kWh/m2 elenergi. Totalt innebar åtgärdspaketet en relativ energibesparing på 27 % av dagens behov.
14

Effektivitetsanalys av Vakuumsystemet i Pappersmaskin 1 : En del av energikartläggningen på Nymölla Bruk / Efficiency Analysis of the Vacuum System in Paper Machine 1

Svensson, Anton, Liljeqvist, Leon January 2019 (has links)
Nymölla Mill is a papermill in the paper division of Stora Enso. Due to its size, the company is forced by law to make energy mappings every fourth year, in order to ensure that that the company is running its business in a sustainable way. When performing an energy mapping, one is supposed to make deeper analyses of the more energy demanding functions at the company as well as a more general mapping of the entire business. The vacuum system in one of the paper machines (paper machine 1) at the mill, is a major energy consumer and is therefore required by law to be analyzed more deeply. This analysis will constitute the main focus of this bachelor thesis, which is made by two students at Jönköping’s School of Engineering, with a total of 30 credits (15 credits per student). The purpose of this thesis is to assist Nymölla Mill in their work with the energy mapping, by making an efficiency analysis of the vacuum system in paper machine 1. The hope is that this thesis will contribute with improvement suggestions, which will make the whole business more efficient and sustainable in an energy perspective. To support this purpose two research questions was formulated, where the first one focuses on the energy losses in the vacuum system and the other on the possible improvements. In order to get the necessary background knowledge, a literature study was made where the law entitled “Lagen om energikartläggning i stora företag” stood in the center. Available energy data has been analyzed and processed in order to form the basis of the energy mapping. In the aim of getting a nuanced picture of the focal point, own observations have been performed alongside with interviews of people who has different perspectives of the vacuum system. The research questions were investigated through analyzing the result of the findings alongside with the literature in the theoretical background. The primary literature focus was on lean, since it was requested by the company itself. The thesis finally resulted in that energy losses were identified and that suggested actions were brought up and discussed. / Nymölla Bruk är ett pappersbruk i Stora Ensos pappersdivision. På grund av företagets storlek måste det enligt lag utföra energikartläggningar vart fjärde år. Detta för att säkerställa att man driver sin verksamhet på ett hållbart sätt. I en energikartläggning ska man främst utföra djupare analyser på de mer energikrävande funktionerna i verksamheten och en mer övergripande kartläggning av hela verksamheten. Vakuumsystemet i en av pappersmaskinerna (pappersmaskin 1) på bruket är en stor energianvändare och kräver därför enligt lag en djupare energianalys. Denna analys utgör huvudfokus i detta examensarbete som är på kandidatnivå av två studenter på Jönköpings Tekniska Högskola, med en total poängomfattning på 30 hp (15 hp per student). Syftet med arbetet är att assistera Nymölla Bruk i deras arbete med energikartläggningen, genom att göra en effektivitetsanalys av vakuumsystemet i pappersmaskin 1. Förhoppningen är att arbetet ska kunna bidra med förbättringsförslag som gör verksamheten mer effektiv och hållbar ur ett energiperspektiv. Som stöd till detta syfte har två frågeställningar formulerats, där den första fokuserar på förluster i vakuumsystemet och den andra på förbättringsmöjligheter. För att skapa den nödvändiga kunskapsgrunden genomfördes en litteraturstudie där lagen om energikartläggning i stora företag stod i centrum. Tillgängliga energidata har behandlats och bearbetats med syftet att utgöra grunden i energikartläggningen. I strävan efter en nyanserad bild av fokusområdet har egna observationer genomförts tillsammans med intervjuer av personer med olika perspektiv av vakuumsystemet. Frågeställningarna utreddes genom att analysera resultatet i nulägesbeskrivningen tillsammans med den litteratur som studerats i det teoretiska ramverket. Extra fokus lades på litteraturen om lean, eftersom det var ett önskemål från företaget. Arbetet resulterade slutligen i att energiförluster identifierades och att möjliga åtgärder för dessa togs fram och diskuterades.
15

Energikartläggning av biogasanläggningen, Kungsängens gård / Energy mapping at the biogas plant, Kungsängens gård

Andersson, Mats January 2011 (has links)
The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed. The objective of this energy survey was to obtain a detailed understanding of the energy use in the biogas production. The energy survey was divided into two parts: electricity and heat. Each part was treated separately and with somewhat different approach. To estimate the electricity usage during the projcet the rated power of each selected unit operation was noted and multplied with thenmeasured time of usage. By doing that the total amount of energy consumed is obtained. During the project a total amount of 152 kWh/ton electricity was used. The 12 largest electricity consumers had a combined usage of 106 kWh/ton, corrresponding to 70 % . The heat survey was subdivided into hot water and steam. Hot water is used to keep the biogas digesters and facilities warm. Steam is exclusively used in the heat pretreatment. Thermal energy consumption was as following: Keeping the biogas digester warm consumed close to 20 % of the total heating demand, corresponding to 40,8 kWh/ton. Heat pretreatment accounted for 62 % of the total heating demand, corresponding to 129 kWh/ton. Heating demand for other staff facilities accounted for 18 % of the total heating demand, corresponding to 37,7 kWh/ton.
16

Energikartläggning hos RostiGP i Gislaved / Energy audit of RostiGP in Gislaved

Johansson, Anton January 2012 (has links)
In today’s modern age, energy consumption has become a major issue, both from an environmental viewpoint and cost perspective. Because of a rapid technologic change and increased costs of production of electricity, the demand to develop effective methods for energy efficiency industries have grown.The electricity-intensive industries, such as plastic industry, the demand to reduce energy consumption has grown significantly over the past 10 years, which have led to the development of different methods to determine and locate energy-consuming parts in the industry. This also means being able to prioritize and organize activities in the industry.In this study the measurements of voltage, current, power and PF performance on injection molding machines (K-TEC 275 form Ferromatik Milacron in Germany) with a focus to locate, within a machine, various measures that could improve energy use in the plastics industry, in this case RostiGP in Gislaved. These measurements have been carried out with the help of a power quality clamp meter to carry out time logs of the machines for some time during normal word rate. Logging data were analyzed and documented to be used as a basis for access to various measures to improve energy use. In some cases it was carried out with calculations with the value and data from the company itself.While measuring, it was observed that the machines energy use was relatively well optimized for the terms and conditions as they have with their supplier (Gislaved Energy Ltd). This contributed to an improvement by only improving the PF would not be sufficiently to reduce consumption, but to reduce consumption you are forced to reduce the active power through the engine replacement or replacement of devices with new technology that can work more efficiently and cheaper. It also means that it is important to keep your system optimized and are well supervised to avoid unnecessary energy uses in your compressed air system of forgetting the lights in a premises where no staff staying for long periods. / I dagens moderna ålder så har energianvändningen blivit en stor fråga, både ur en miljösynpunkt som kostnadssynpunkt. P.g.a. den snabba tekniska utvecklingen samt förhöjda kostnader på produktion av elektricitet så har efterfrågan att ta fram effektiva metoder för att energieffektivisera industrier vuxit.Inom elintensiva industrier, såsom plastindustrin, så har efterfrågan att kunna minska energiförbrukningen vuxit markant de senaste 10 åren, vilket ha lett till utvecklingen av olika metoder för att kunna avgöra och lokalisera energikrävande punkter inom industrin. Det gäller också metoder för att kunna prioritera och organisera åtgärder som finns inom industrin.Inom denna studie så har mätningar inom spänning, ström, effekt och PF genomförts på formsprutningsmaskiner (K-TEC 275 av Ferromatik Milacron i Tyskland) med fokus att lokalisera, inom en maskintyp, olika åtgärder som skulle kunna förbättra energianvändningen inom plastindustrin, i detta fall RostiGP i Gislaved. Dessa mätningar har genomförts med hjälp av en effektanalysator för att kunna genomföra tidsloggningar på maskinerna under en viss tid under normal arbetstakt. Loggningarna som togs fram analyserades och dokumenterades för att kunna användas som ett underlag för att komma på olika åtgärder som skulle förbättra energianvändandet. I vissa fall så genomfördes beräkningar med värden och underlag som företaget själva bistod med.Under mätningens gång så kunde det observeras att maskinernas energianvändning var relativt bra optimerade efter de villkor och bestämmelser som de har med deras elleverantör (Gislaveds energi AB). Detta bidrog till att förbättringar genom att endast förbättra PF inte skulle vara tillräcklig effektivt för att kunna minska förbrukningen, utan för att kunna minska förbrukningen är man tvungen att minska den aktiva effekten genom maskinbyte eller byta ut olika enheter med ny teknik som kan arbeta effektivare och billigare. Det medför också att det är viktigt att hålla systemen optimerade och under god uppsikt för att undvika onödiga energianvändningar som läckage i tryckluftsystem eller att glömma lyset i en loka där ingen personal vistas under längre tid.
17

Energikartläggning Lagret 8 Skellefteå : Energikartläggning och åtgärdsplan på uppdrag av Fastighets AB Polaris i Skellefteå

Södergren, Nina January 2015 (has links)
En energikartläggning är en rapport som sammanställer energianvändning i en fastighet eller del av en byggnad. Med hjälp av olika mätningar och beräkningar kan man visa vilka delar i byggnaden som kräver mycket energi, både värme och el. I denna kartläggning ingår utredning av energi till ventilation, radiatorer och värme, vatten, kyla, belysning samt elförbrukning och analys av klimatskalet. Utifrån denna kartläggning kan man sedan utarbeta en åtgärdsplan som kan leda till förändringar och ombyggnationer och omprogrammeringar som sparar in på energianvändningen. Denna rapport innehåller en energikartläggning av Lagret 8 i Skellefteå. Förfrågan på denna kartläggning kommer från fastighetsägaren Fastighets AB Polaris som sedan bestämmer om de vill gå vidare med något eller några av de åtgärder som utretts i rapporten. De åtgärder som har utretts är fokuserade på det som Polaris kan påverka och syftar då på driftkostnader och driftenergi. Verksamhetsenergin är något som är svårare att påverka då den varierar med vilken typ av verksamhet som sker i lokalen och i vilken utsträckning. Byggnaden består av tre olika huskroppar som hyrs av fem olika företag och åtgärderna är paketerade så att de fokuserar på varje huskropp för sig. Det finns också outhyrda delar i fastigheten. Åtgärdspaketen som föreslås att förbättra energiprestandan för Lagret 8 är: För Fastighets AB Polaris (SSC, Schneider och Feelgood) Fläktbyten på TA09 Tilläggsisolering av tak på Xzakt-byggnaden Injustering av radiatorer Vinterkompensering på aggregat TA09 För Xzakt Kundrelationer Fläktbyten på TA01 Minska drifttid på TA01 CO2 styrning med spjäll i lunchrum 106 Paus Vinterkompensering av aggregat TA01 För SSC Klingan AB Skellefteå Fläktbyten på TA06Klingan Byte till fjärrstyrd port Närvarostyrd ventilation på Lager/Svets (Rum nummer: SVETSARE) Vinterkompensering av aggregat TA02, TA03 och TA05. / This report is the result of three years of studying to get a degree in Bachelor of Science in energy technology and it contains an energy audit of Lagret 8 in Skellefteå owned by Fastighets AB Polaris. The building consists of three connected buildings which are rented by five different companies. There are also vacant parts of the property. This energy audit includes the investigation of energy for ventilation, radiators and heat, water, air-conditioning, lighting and electricity consumption and analysis of the building envelope Based on this investigation an action plan have been developed and the changes to be done will hopefully lead to a better environment inside the building and also contribute to lower the energy consumption.   The calculations of energy savings and pay-back time in the action plan are focused on the ones that Polaris can affect and do something about. The ones that can be affected are for example energy for ventilation and air-conditioning. Operational energy is something that is more difficult to influence as it varies with the type of activity that takes place in the facility and to what extent   The action plan to improve the energy performance of Lagret 8 are sorted for every part of the building. They are presented below:   For Fastighets AB Polaris (SSC, Schneider Electrics and Feelgood företagshälsa) Ventilation fan replacement on TA09 Additional insulation of roofs on Xzakt building Balancing the temperature of the radiators Winter compensation to TA09 For Xzakt Kundrelationer AB Ventilation fan replacement on TA01 Reduce the operating time of TA01 CO2 control with a throttle in the lunchroom 106 Paus Winter compensation of TA01 For SSC Klingan AB Skelleftea Ventilation fan replacement on TA06Klingan Change to RC doors Presence -controlled ventilation in storage area ( Rooms number: WELDER ) Winter compensation of TA02 , TA03 and TA05 .
18

Energikartläggning i Sundbybergs stad / Mapping of Energy Consumption in Municipal Buildings in the City of Sundbyberg

Söderkvist, Lina, Dégeus, Malin January 2007 (has links)
No description available.
19

Energikartläggning av tand- och vårdcentralen i Lessebo

Lindskär, Lindskär, Rydell, Jimmy January 2013 (has links)
För att kunna minska den ständigt ökande energianvändningen i världen så måstebyggnader energieffektiviseras, för att kunna göra en energieffektivisering är ett braverktyg att först göra en energikartläggning. Denna rapport uppskattarenergiförbrukningen såväl som inneklimatet i Lessebos tand- och vårdcentral, byggnadenstod klar i november 2011. Fastighetsägarna vill att fastigheten ska uppnå energistämpelngreenbuilding © , som utlovar en uppvärmning och driftkostnad på högst 75 kWh/m2inklusive fastighetsel, exklusive verksamhetsel. Tillsammans med energikartläggningensom har gjorts genom att mäta och uppskatta varje elektrisk maskins energiförbrukninghar en analys av inneklimatet gjorts. Detta gjordes genom att göra en enkät sompersonalen fick svara på samt mäta sex olika värden i tre av rummen för att teoretisktberäkna missnöjdheten av hur personalen uppfattar inneklimatet. För ett av dessa rum därmätningar inte var möjliga har en simulering över temperaturen för sommaren gjorts.Den totala värme- och fastighetselförbrukningen mellan sista augusti 2012 till sistaaugusti 2013 uppskattas till 69 kWh/m2. Därmed uppnår byggnaden de krav som ställs föratt byggnaden ska få energistämpeln greenbuilding. Totala elanvändningen för fastighetenär 18 % lägre än den genomsnittsliga vårdlokalen enligt energimyndighetens granskningöver vårdlokaler 2007. Enligt en modell/simulering så borde 66 % av personalen varamissnöjda med personalrummet (1037) vintertid, vilket stämmer bra överens medenkätsvaren som säger att 65 % är missnöjda
20

Energikartläggning av en äldre fastighet : En kartläggning kring energiförbrukningen och kostnadsbesparande lösningar för en äldre fastighet

Lindgren, Rickard January 2016 (has links)
On the behalf of Norrporten in Umeå have an energy audit been made on an older part of a building. The goal has been to calculate the distribution of energy carriers in the property and to find out what the operating cost for the building is. With that in mind so have different methods to reduce energy and operating costs been examined and its effect on energy consumption. This survey analyzes ventilation, heating, water heating and climate shell of the property. Measures to reduce energy consumption due to operations in the building have not been examined. The simulation program IDA ICE was used for energy calculations. The results show that the property currently use about 150 MWh/year of heat and about 104 MWh/year of electricity. This means an annual operating cost of about 200 600 SEK. Among the largest energy consuming parts are: Heating of the facility Heating of domestic hot water Ventilating el for fan operation The total savings opportunity is apparent to about 14,600 kWh/year of electricity and about 39,600 kWh/year of district heating.