• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1466
  • 17
  • 16
  • 15
  • 15
  • 11
  • 10
  • 8
  • 7
  • 7
  • 5
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 1537
  • 773
  • 607
  • 598
  • 356
  • 276
  • 160
  • 156
  • 153
  • 151
  • 139
  • 127
  • 123
  • 115
  • 111
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Determinação das doses efetivas de alimentos, água e solo na região do CAUB-I através da espectrometria de raios gama / Determination of the effective doses of foods, water and ground in the region CAUB-I through the gamma spectrometry technique

Ferreira, Katrine Cappucio 23 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2018. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-16T19:46:17Z No. of bitstreams: 1 2018_KatrineCappucioFerreira.pdf: 1839461 bytes, checksum: f5f2a6f874fe8fdab8cabd50e22d6d6a (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T21:25:22Z (GMT) No. of bitstreams: 1 2018_KatrineCappucioFerreira.pdf: 1839461 bytes, checksum: f5f2a6f874fe8fdab8cabd50e22d6d6a (MD5) / Made available in DSpace on 2018-07-20T21:25:22Z (GMT). No. of bitstreams: 1 2018_KatrineCappucioFerreira.pdf: 1839461 bytes, checksum: f5f2a6f874fe8fdab8cabd50e22d6d6a (MD5) Previous issue date: 2018-07-16 / Estudo de índices de radioatividade no ambiente tem grande importância no monitoramento de níveis de radiação a que o homem está exposto, seja direta ou indiretamente. Nesse sentido, este trabalho teve como objetivo a determinação experimental das doses efetivas de radiação natural e artificial presentes em alimentos, água, solo e fertilizante, na região administrativa produtora de alimentos CAUB-I, localizada no Distrito Federal. Para tal, foram coletados e analisados através da técnica de espectrometria Gama cuja atividade foi medida empregando-se detector HPGe (High Pure Germanium). Os resultados obtidos mostraram o elemento Bismuto (210Bi) encontrado em amostras de solo com atividade reduzida variando entre 5,47 ± 0,03 e 12,57 ± 0,13 Bq/kg-1 enquanto o elemento Chumbo (210Pb) apresentou valores entre 10,55 ± 0,14 a 55,5 ± 0,50 Bq/kg-1. Em praticamente todas as amostras de água foi detectado a presença do elemento Potássio (40Ka) com variação entre 4,02 a 15,4 Bq/kg-1. A amostra de fertilizante apresentou os elementos 40K e o 235U, sabe-se que os outros elementos estão na cadeia de decaimento do Urânio; sendo assim podemos considerar que toda a cadeia está contaminada com esses radionuclídeos. A dose efetiva calculada foi abaixo dos valores da UNSCEAR e do CENEN, entretanto não exime a contaminação da população pelos radionuclídeos. / Study of radioactivity indices in the environment is of great importance without monitoring of levels of radiation to whom the man is exposed, either directly or indirectly. In this sense, the objective of this work was the experimental determination of the effective doses of natural and artificial radiation present in food, water, soil and fertilizer in the administrative administrative region of food CAUB-I, located in the Federal District. For the control of HPGe (High Pure Germanium). The results showed the Bismuth element (210Bi) found in soil samples with reduced activity ranging from 5.47 ± 0.03 to 12.57 ± 0.13 Bq/kg-1 while the element Lead (210Pb) presented values between 10,55 ± 0.14 to 55.5 ± 0.50 Bq/kg-1. In practically all the water samples to detect a presence of the element Potassium (40Ka) with variation between 4.02 to 15.4 Bq/kg-1. A sample of fertilizer showed the elements 40K and 235U, other elements are known to be in the Uranium decay chain; Be well informed with these radionuclides. An effective dose calculated and below the values of UNSCEAR and CENEN, between which there is no contamination of the population by radionuclides.
52

Caracterização de estirpes de Aeromonas Spp. E Esherichia Colli através de Espectrometria de Massa Maldi-tof

Dallagassa, Cibelle de Borba January 2012 (has links)
Orientadora : Profa. Dra. Cyntia M.T. Fadel Picheth / Co-orientadores : Profa. Dra. Leda S. Chubatsu, Prof. Dr. Luciano Huergo / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Ciências Farmacêuticas. Defesa: Curitiba, 01/03/2012 / Bibliografia: fls. 59-68 / Área de concentração: Análises clínicas / Resumo: Aeromonas spp. são bactérias capazes de causar uma série de infecções em humanos, variando de diarréia não complicada até meningite e septicemia. Escherichia coli fazem parte da microbiota intestinal de humanos, onde são benéficas para o hospedeiro. No entanto existem estirpes patogênicas capazes de causar infecções intestinais, denominadas E. coli diarreiogênicas (DEC), e extra-intestinais (ExPEC) como as E. coli uropatogênicas (UPEC). O objetivo desse trabalho foi caracterizar estirpes de Aeromonas spp. e E. coli através de Espectrometria de Massa MALDI-TOF. Foram analisadas 99 estirpes de Aeromonas spp. e 143 estirpes de E.coli, incluindo comensais isoladas da microbiota intestinal, patotipos, e estirpes de referência. As bactérias foram cultivadas em ágar MacConkey por 18 horas, a 36±1°C, ao ar. O extrato celular preparado a partir de ~10 colônias foi utilizado para análise. O ácido ?-ciano-4-hidroxicinâmico (10 mg/ml) dissolvido em acetonitrila:ácido trifluoroacético 2,5% (1:1) foi utilizado como matriz. Alíquotas dos extratos foram analisadas em espectrômetro de massa MALDI-TOF-MS (Autoflex; Bruker Daltonics) equipado com um laser de nitrogênio (337nm) (Bruker Daltonics). Os íons positivos foram obtidos utilizando uma aceleração de 20Hz no modo linear. Os espectros resultaram da soma dos íons obtidos de 100 tiros do laser em 10 posições diferentes da amostra. A aquisição dos espectros foi realizada de forma manual com uma resolução mínima de 600 arb e máxima de 1500 arb e analisados em uma faixa de relação carga/massa (m/z) de 3.000 a 20.000 Da.O processamento dos espectros foi realizado utilizando o software Flex Analysis v. 3.0 (Bruker Daltonics).Para E. coli os ensaios foram feitos em triplicata, e para Aeromonas spp em triplicata e em duas datas diferentes. Os espectros gerados foram analisados com o software Speclust gerando a lista de picos em comum e um dendrograma. Os picos m/z 4259, 5051, 6304 foram detectados em todas as estirpes de Aeromonas analisadas, o que indica que podem ser marcadores para bactérias deste gênero. O pico m/z 9180 foi observado em Aeromonas spp e E. coli, mas é importante para a identificação de Aeromonas. A espectrometria de massa MALDI-TOF foi capaz de diferenciar as espécies de Aeromonas. Dois picos, m/z 5380 e 7271, foram encontrados em todas as estirpes de E. coli analisadas. Os picos m/z 4364, 5095, 6253, 6314, 9060 e 9532 foram observados em 92 a 99% das E. coli. Estes picos são importantes para identificar E. coli. Foi possível diferenciar o grupo das E. coli comensais e das UPEC das demais categorias dessa bactéria. A metodologia de MALDI-TOF tem capacidade para distinguir as bactérias estudadas, no entanto é necessário otimizar a metodologia para distinguir maior número dos grupos de E. coli. / Abstract: Aeromonas spp are bacteria associated with human infections varying from diarrhea to meningitis and septicemia. Escherichia coli are part of intestinal microbiota of humans where are beneficial to host. However there are several pathogenic strains able to cause intestinal infections, called diarrheagenic E. coli (DEC), and extra-intestinal infections (ExPEC), as uropathogenic E. coli (UPEC). The aim of this work was to characterize Aeromonas and E. coli strains using MALDI-TOF Mass Spectrometry. We analyzed 99 Aeromonas strains, and a total of 143 E. coli including commensal, pathotypes and reference strains. Bacteria were grown overnight on MacConkey agar at 36±1°C, under air. Cells extracts were prepares with ~10 colonies. Alpha-cyano-4-hydroxycinnamic acid (10mg/ml) in acetonitrile:2,5% trifluoroacetic acid (1:1) was used as matrix. Aliquots of extracts were analyzed in a MALDI-TOF mass spectrometer (Autoflex, Bruker Daltonics) equipped with a nitrogen laser (337 nm). The positive ions were obtained with a 20 Hz acceleration in linear mode. The spectra were obtained from the sum of 100 laser shots in 10 different positions of sample. Acquisition of spectra was performed manually with a minimum resolution of 600 and maximum of 1500 arb, in a range of 3000 - 20000 Da. Processing of spectra was done with Flex Analysis v.3 (Bruker Daltonics). For E.coli tests were realized in triplicates, and for Aeromonas spp in triplicates and at 2 different days. The spectra were analyzed with software SPECLUST which generated lists of common peaks and a dendrogram. Peaks m/z 4259, 5051, 6304 were found in all Aeromonas strains, indicating that may be markers for the genera. Peak m/z 9180 was found in Aeromonas spp and also in E. coli, but is also important to identification of Aeromonas. MALDI-TOF mass spectrometry allowed to distinguish Aeromonas species. In E. coli, peaks m/z 5380 and 7271 were found in all strains. Peaks m/z 4364, 5095, 6253, 6314, 9060 and 9532 were detected in 92 to 99% of E. coli. All these peaks are important to identify E. coli strains. In addition, commensal E. coli strains and UPEC strains were distinguished from other categories of these bacteria. The MALDI-TOF metodology has the ability to distinguish the bacteria studied, however it should be optimized to achieve this objective.
53

Desenvolvimento de metodologias analíticas para avaliar a digestibilidade de nutrientes metálicos utilizados na nutrição de peixes

Neves, Renato de Cássio Ferreira [UNESP] 01 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-01Bitstream added on 2014-06-13T19:35:48Z : No. of bitstreams: 1 neves_rcf_me_botfmvz.pdf: 1630721 bytes, checksum: 6496f87884155504d466203bb4b0406e (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / O objetivo do presente trabalho foi desenvolver e otimizar um método para determinação de cobre em amostras de fezes e rações de peixes por GFAAS utilizando-se a introdução direta de suspensões das amostras no tubo de grafite do espectrômetro recoberto internamente com carbeto de tungstênio como modificador permanente. Os limites de detecção (LOD) e de quantificação (LOQ) calculados em relação a 20 leituras do branco das suspensões (0,50 % m/v de fezes ou ração isentas de cobre) foram de 0,24 e 0,79 μg L-1 para as suspensões padrão de fezes e de 0,26 e 0,87 μg L-1 para as suspensões padrão de ração. O método proposto foi aplicado em estudos de digestibilidade de cobre em diferentes amostras de rações de peixes e mostraram-se de acordo com os resultados obtidos utilizando amostras previamente mineralizadas por digestões ácidas utilizando-se forno de microondas. / The aim of the present work was to develop and optimize a method to determine copper in samples of feces and fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer’s graphite tube coated internally with tungsten carbide that acts as chemical modifiers. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (0.50 % m/v of feces or feed devoid of copper) were 0.24 and 0.79 μg L-1 for the standard feces slurries and 0.26 and 0.87 μg L-1 for the standard feed slurries. The proposed method was applied in studies of digestibility of copper in different fish feeds and their results proved compatible with that obtained from samples mineralized by acid digestion using microwave oven.
54

Perfil lipídico do sêmen de touros Nelore (Bos taurus indicus) de alta e baixa resistência espermática à criopreservação / Lipid profile the bull’s semen Nelore (Bos taurus indicus) high and low sperm cryopreservation resistance

Zorzetto, Mariana Furtado [UNESP] 01 July 2016 (has links)
Submitted by MARIANA FURTADO ZORZETTO (mary-zorze@hotmail.com) on 2017-05-30T20:52:06Z No. of bitstreams: 1 Tese Mariana Zorzetto.pdf: 1032812 bytes, checksum: 6bf6fb1f8c4f684c7b15d0acf665a4cb (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-05-31T18:03:24Z (GMT) No. of bitstreams: 1 zorzetto_mf_dr_bot.pdf: 1032812 bytes, checksum: 6bf6fb1f8c4f684c7b15d0acf665a4cb (MD5) / Made available in DSpace on 2017-05-31T18:03:24Z (GMT). No. of bitstreams: 1 zorzetto_mf_dr_bot.pdf: 1032812 bytes, checksum: 6bf6fb1f8c4f684c7b15d0acf665a4cb (MD5) Previous issue date: 2016-07-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A composição dos lipídeos da membrana espermática e do plasma seminal estão entre os fatores que podem influenciar a capacidade fecundante do sêmen. Desta maneira, este estudo objetivou analisar as diferenças do perfil lipídico do ejaculado de bovinos da raça Nelore, resistentes e sensíveis à criopreservação. Foram utilizados 15 touros da raça Nelore para colheitas de sêmen utilizando eletroejaculador. Os ejaculados foram diluídos com meio convencional na concentração de 25x106 espermatozoides/palheta. Os animais foram divididos em dois grupos conforme a resistência pós-criopreservação, grupo A (Bad freezer, touros sensíveis à criopreservação) e grupo B (Good freezer, touros resistentes à criopreservação). O sêmen fresco foi analisado quanto morfologia realizada por microscopia de interferência diferencial (DIC), cinética espermática e integridade da membrana. Na pós-descongelação as amostras foram avaliadas quanto a cinética espermática, integridade das membranas plasmáticas e acrossomal, caspase ativa, peroxidação lipídica. A análise do perfil de lipídios foi realizada por espectrometria de massa MALDI-MS. Foi possível observar diferença no perfil lipídico dos espermatozoides e do plasma seminal entre os grupos, com maior abundância relativa dos íons m/z 704,59; m/z 804,59 e m/z 943,77 no grupo A nos espermatozoides. No plasma seminal houve maior abundância relativa de 34 íons lipídicos nos touros do grupo B. Assim sendo, conclui-se que existe diferença no perfil de lipídios dos espermatozoides e no plasma seminal de touros sensíveis ou resistentes à criopreservação. / Lipid compositions of the sperm membrane are among the factors that can influence the semen fertilizing capacity. Likewise, the lipid composition of seminal plasma can interfere in sperm quality. In this sense, this study aimed to analyze differences between lipid profile of the ejaculate and sperm parameters from bulls (Nelore breed) wich are resistant and susceptible to cryopreservation. In the study 15 Nelore bulls were used for semen collection by electroejaculation. The samples were diluted with yolk egg-based extender (Botu-Bov®). The animals were divided into two groups according to semen quality after cryopreservation: group A (Bad freezer, bulls sensitive to cryopreservation) and group B (Good freezer, bulls resistant to cryopreservation). Fresh semen was analyzed for sperm morphology by differential interference contrast microscopy (DIC), kinetic parameters by CASA and by plasma membrane integrity by epifluorescence microscopy. In post-freezing the samples were evaluated for kinetic parameters by CASA, sperm viability by flow cytometry (plasma and acrosomal membrane integrity, lipid peroxidation and active caspase) and plasma mebrane integrity by epifluorescence microscopy. Analysis of lipid profile were carried out by mass spectrometry MALDIMS of the sperm membrane lipids (Experiment 1) and from seminal plasma (Experiment 2). In Experiment 1 was observed difference in sperm lipid profile between the groups. The group A showed highest relative abundance of ions m/z 704.59; m/z 804.59 e m/z 943.77 on spermatozoa. In seminal plasma, here was a greater relative abundance of 34 lipid ions in bulls than group B. Therefore, in conclusion there are differences in the sperm lipid profile and seminal plasma lipid profile between sensitive or resistant bulls to semen cryopreservation.
55

Otimização dos procedimentos de extração e desempenho analítico da espectrometria de emissão ótica com plasma acoplado indutivamente na análise de amostras de solos / Procedures optimization of extraction and analytical performance of the inductively coupled plasma optical emission spectrometry in analysis of soil samples

Santos, Lenio da Silva January 2018 (has links)
Os avanços da química analítica instrumental permitiram uma melhoria substancial na obtenção de informações importantes em diferentes áreas do conhecimento, dentre elas a Ciência do Solo. Este trabalho abordou questões relacionadas à análise química de solo por espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES). Estudos envolvendo correlação de resultados, determinação simultânea multielementar e interferências da técnica de ICP OES foram abordados em quatro capítulos: 1) revisão bibliográfica sobre ICP OES abordando funcionamento, interferências e usos com diferentes extratores; 2) teores de potássio, cálcio, magnésio, alumínio, enxofre, cobre, zinco, manganês e boro determinados por ICP OES em amostras de solo do sul do Brasil; 3) extração multielementar pela solução de Mehlich-3 e determinação simultânea por ICP OES em amostras de solo; 4) eficácia do Multicomponent Spectral Fitting (MSF) na estimativa do valor correto de fósforo determinado por ICP OES. As principais conclusões foram: 1) relações lineares significativas entre teores dos K, Ca, Mg, Al, S, Cu, Zn, Mn e B determinados por ICP e técnicas de referência; 2) a técnica ICP apresentou maior sensibilidade em relação a titulação para determinar Al trocável 3) A interpretação dos resultados do B com base nos valores obtidos pelo método curcumina-COL pode ocasionar erros devido a este não ser hábil em discriminar teores entre a estreita faixa de deficiência e suficiência para este elemento; 4) O uso da solução de Mehlich-3 em conjunto com a técnica de ICP OES teve correlação significativa para a extração de P, K, Ca, Mg, Cu e Zn em amostras de solo, podendo ser utilizado em laboratórios de análise de solo, embora não se tenha ganho prático em utilizá-la devido não ser possível determinar Al e Mn; 5) A solução de Mehlich-3 extraiu teores de Al, S, Mn e de B que não se correlacionaram significativamente com os teores extraídos pelas soluções extratoras de referência, não sendo, nas condições testadas, recomendado seu uso em conjunto com a técnica de ICP OES para a finalidade de diagnóstico da disponibilidade destes elementos; 6) A eficácia do MSF para determinar o valor verdadeiro de fósforo em matriz contendo Cu foi dependente da concentração de Cu e da relação fósforo:cobre; 7) A linha espectral do P em 213,618 nm foi mais sensível à presença do Cu em solução sendo preferível utilizar os resultados da linha espectral em 214,914 nm para determinação do P quando não utilizado o ajuste MSF. / Advances in instrumental analytical chemistry have allowed a substantial improvement in obtaining important information in different areas of knowledge, such as Soil Science. This work addressed questions related to soil chemical analysis by inductively coupled plasma optical emission spectrometry (ICP OES). Studies involving correlation of results, simultaneous multielementar determination and interferences of the ICP OES technique were addressed in four chapters: 1) bibliographic review on ICP OES addressing operation, interferences and uses with different extractors; 2) potassium, calcium, magnesium, aluminum, sulfur, copper, zinc, manganese and boron determined by ICP OES in soil samples from southern Brazil; 3) multielement extraction by the Mehlich-3 solution and simultaneous determination by ICP OES in soil samples; 4) efficiency of the multicomponent spectral fitting (MSF) in the estimation of the correct value of phosphorus determined by ICP OES. The main conclusions about these studies were: 1) Significant linear relationships were found for K, Ca, Mg, Al, S, Cu, Zn, Mn and B determined by ICP and reference techniques; 2) The ICP technique presented higher sensitivity in relation to titration to determine Al in the extracts (3) The interpretation of the results of B on the basis of the values obtained by the curcumin-COL method may lead to errors because it is not able to discriminate between the narrow range of deficiency and sufficiency for this element; 4) The use of the Mehlich-3 solution in conjunction with the ICP OES technique had significant correlation for the extraction of P, K, Ca, Mg, Cu and Zn in soil samples, and could be used in soil analysis laboratories, although there is no practical gain in using it because it is not possible to determine Al and Mn; 5) The Mehlich-3 solution extracted contents of Al, S, Mn and B that did not significantly correlate with the contents extracted by the reference extractor solutions, and it was not recommended, under the conditions tested, its use in conjunction with the ICP OES for the purpose of diagnosing the availability of these elements; 6) The efficacy of the MSF to determine the true value of phosphorus in the Cu-containing matrix was dependent on the concentration of Cu and the phosphorus:copper ratio; 7) The spectral line of P at 213.618 nm was more sensitive to the presence of Cu in solution and it is preferable to use the spectral line of 214.914 nm for determination of P when the MSF setting is not used.
56

Métodos de avaliação da disponibilidade de Potássio para as plantas em solos do Rio Grande do Sul / Methods for assessing the availability of potassium for plants in soil of Rio Grande do Sul

Amorim, Magno Batista January 2014 (has links)
Os principais laboratórios de análise de solo de rotina brasileiros utilizam a solução Mehlich-1 para determinação de potássio disponível no solo. Os outros cátions de maior importância no complexo de troca (Ca, Mg, Mn, Na e Al) são determinados pela solução de cloreto de potássio (KCl 1,0 mol L-1). Porém estes procedimentos possuem limitações químicas e operacionais. Logo, a necessidade de novos extratores é discutida no meio cientifico, principalmente com a recente adoção da técnica de espectrometria de emissão ótica por plasma acoplado indutivamente (ICP-OES). Assim, o objetivo do presente estudo foi comparar diferentes soluções extratoras (Mehlich-1, Melich-3, KCl 1,0 mol L-1 e NH4Cl 1,0 mol L-1) com a solução padrão de AcNH4 1,0 mol L-1, como extratores de K e demais cátions do solo, e verificar a capacidade dos extratores em predizer a disponibilidade de K para as plantas em solos do Rio Grande do Sul. Para isso, foram desenvolvidos três estudos, dois em laboratório e um em casa de vegetação. Nos estudos em laboratório foram utilizados diferentes tempos de agitação (5, 30 e 60 minutos), relação solo:solução (1:5, 1:10 e 1:20 v/v) e tempos de decantação (2 e 16 horas). Em casa de vegetação foram conduzidos dois cultivos com milho. Os coeficientes de correlação entre todos os métodos foram altos. No entanto, os valores obtidos pela solução de Mehlich-1 foram, em geral, menores que os obtidos por AcNH4 e NH4Cl, mesmo quando o tempo de agitação foi aumentado. Quando a relação solo:solução foi diminuída o Mehlich-1 extrai ainda menos K do solo. Os teores obtidos de K, Ca, Mg, Mn, Al e Na pela solução NH4Cl 1,0 mol L-1, com no mínimo 30 minutos de agitação, foram semelhantes aos obtidos pelos procedimentos padrão de AcNH4 (K) e KCl (Ca, Mg, Mn, Al e Na), independente da relação solo:solução e do tempo de decantação. Todas as soluções foram eficientes em predizer a disponibilidade de K para as culturas. De modo geral os resultados obtidos indicam que é viável substituir as soluções tradicionais Mehlich-1 e KCl 1,0 mol L-1 na extração de cátions trocáveis do solo, pela solução de NH4Cl mol L-1 em laboratórios que dispõem de ICP-EOS. / The main Brazilian soil testing laboratories use Mehlich-1 solution for determination of available potassium in the soil. The other most important cations in the exchange complex (Ca, Mg, Mn, Na and Al) are determined using a solution of potassium chloride (KCl 1.0 mol L- 1). However, these procedures have chemical and operational limitations. Therefore, the need for new extractors is discussed in the scientific environment, especially with recently adoption of ICP-OES in routine soil testing laboratories. The aim of this study was to compare different extraction solutions (Mehlich-1, Melich-3, KCl 1.0 mol L-1 and NH4Cl 1.0 mol L-1) with the standard solution of 1.0 mol L AcNH4-1, as K, Ca, Mg, Mn, Na and Al extractors from the soil, and verify the ability of extractants to predict K availability to plants in soils of Rio Grande do Sul. Treatments tested in laboratory consisted of three soill:solution ratio (1:5, 1:10 and 1:20 v / v), two settling times (2 and 16 hours) and three agitation times (5, 30 and 60 minutes). In the greenhouse were made two maize crops cycles. The correlation coefficients between all methods were high. However, the values obtained by Mehlich-1 solution were generally lower than values obtained using AcNH4 NH4Cl and even when the stirring time was increased. When the soil:solution ratio decreased, Mehlich-1 extract less exchangeable K. The values obtained to K, Ca, Mg, Mn, Al and Na using NH4Cl 1.0 mol L-1 solution, at least 30 minutes of stirring, were similar to values obtained by standard procedures AcNH4 (K) and KCl (Ca, Mg, Mn, Al and Na), regardless of soil:solution ratio and settling time. All solutions were effective in predicting K availability to agricultural cultures. Overall the results indicate that it is feasible to replace the traditional solutions Mehlich-1 and KCl 1.0 mol L-1 in the extraction of soil exchangeable cations by solution of NH4Cl mol L-1 in laboratories that have an ICP - EOS.
57

Produção de padrões para análise espectrométrica por emissão óptica de uma liga de aço AISI/SAE 1020

Brehm, Feliciane Andrade January 1999 (has links)
A composição química dos aços é de fundamental importância para suas propriedades mecânico-metalúrgicas. Durante o processo de fabricação de ligas metálicas, faz-se normalmente uso do espectrômetro de emissão óptica para a determinação da composição química. Este equipamento é capaz de fornecer uma análise multielementar em um intervalo de tempo muito pequeno, permitindo, assim, possíveis correções necessárias para obtenção da composição química final desejada antes do vazamento. Esta ferramenta tem como princípio de funcionamento a análise comparativa, necessitando de materiais de referência, também chamados padrões, para sua recalibração. A principal característica destes materiais de referência é sua homogeneidade em termos de composição química e física. O presente trabalho tem a finalidade de analisar a metodologia adotada para produzir padrão de referência de um aço AISI/SAE 1020 através de um programa interlaboratorial. As amostras foram obtidas por meio de um tarugo proveniente de um processo de lingotamento contínuo, que foi tratado termo-mecanicamente por processos de laminação, forjamento e usinagem antes da obtenção das amostras propriamente ditas. Após uma análise prévia da superfície das amostras, estas foram distribuídas aos integrantes do grupo analítico e analisadas nos espectrômetros de emissão óptica existentes nos seus próprios laboratórios. Foi realizada, ainda, uma análise metalográfica da superfície das amostras para que fosse verificada a homogeneidade microestrutural das amostras. O tratamento estatístico dos dados, baseado na norma ISO Guide 35, e a análise metalográfica comprovam que é possível certificar tecnicamente os teores dos elementos carbono, silício, manganês, fósforo, enxofre, cromo, níquel, molibdênio, alumínio, estanho e cobre nos materiais de referência. / The chemical composition of steel is extremely important for its mechanical and metallurgical properties. During the processing of metallic alloys, an optical emission spectrometer is used to determine the chemical composition. This equipment is able to give a multielementar analysis in a very short time interval, enabling corrections that may be necessary to obtain the final chemical composition of the casting. The working principle of this tool is the comparative analysis that needs standards, also called reference materials for its calibration. The main characteristic of these reference materials is their homogeneity in terms of physical and chemical properties. The present work aims to analyze the methodology adopted to produce the reference pattern of an AISI/SAE 1020 steel, through an interlaboratorial program. The samples were obtained from billets, which were produced via continuous casting process. Before obtaining samples the billets passed through rolling, forging and machining processes. After a previous analysis of the sample surface, the samples were distributed to the members of the analytical group, who analyzed them on the optical emission spectrometers from their own laboratories. Furthermore, a microstructure analysis of the sample surface was carried out to verify the microstructural homogeneity of the samples. The data statistic treatment, based on the ISO Guide 35 standard, and the microstructure analysis prove that it is possible to certify, technically, the content of the elements carbon, silicon, manganese, phosphorous, sulfur, chromium, nickel, molybdenum, aluminum, tin, copper in the reference materials.
58

Microscopia de força atômica associada à espectrometria de massa na caracterização de sistemas protéicos

Logrado, Daniel Lima 06 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, 2009. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2010-03-10T18:47:46Z No. of bitstreams: 1 2009_DanielLimaLogrado.pdf: 4716490 bytes, checksum: 5cc801a6d076dff66b230bb9caddb891 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-05-11T18:33:52Z (GMT) No. of bitstreams: 1 2009_DanielLimaLogrado.pdf: 4716490 bytes, checksum: 5cc801a6d076dff66b230bb9caddb891 (MD5) / Made available in DSpace on 2010-05-11T18:33:52Z (GMT). No. of bitstreams: 1 2009_DanielLimaLogrado.pdf: 4716490 bytes, checksum: 5cc801a6d076dff66b230bb9caddb891 (MD5) Previous issue date: 2009-06 / Visando o desenvolvimento de uma metodologia analítica rápida e econômica orientada para estudos de sistemas moleculares formados por proteínas, o presente trabalho teve como objetivo primordial a associação entre duas poderosas técnicas para análise de proteínas, a microscopia de força atômica (AFM) e a espectrometria de massa (MS). Tendo como perspectiva principal para a associação AFM-MS o estudo do interatoma. A microscopia de força atômica é uma importante técnica para análise de sistemas supramoleculares, dentre outras informações, permite à obtenção da topografia desses sistemas possibilitando que as dimensões das estruturas que o compõe sejam mensuradas, sendo assim, essa ferramenta de análise fornece informações importantes no que diz respeito a estruturas quaternárias formadas por proteínas, sugerindo como as subunidades interagem para formação de complexos moleculares. A determinação precisa da massa molecular por espectrometria de massa possibilita a solução de diversos problemas relacionados às questões bioquímicas, como a determinação direta das estruturas primária e quaternária de proteínas, determinação de modificações pós traducionais, identificação de proteínas e etc. Graças a sua versatilidade e sensibilidade, a espectrometria de massa vem se destacando como ferramenta indispensável para a análise de proteínas. O presente trabalho propõe a associação da microscopia de força atômica com a espectrometria de massa objetivando análises rápidas nas quais uma mesma amostra é submetida às duas ferramentas analíticas, identificando, também, em quais aspectos essas duas técnicas se complementam na investigação de sistemas protéicos. Nos experimentos, proteínas adsorvidas em superfície de mica, suporte frequentemente utilizado nas análises por AFM, tiveram sua morfologia estudada por AFM e, em seguida, foram analisadas por MALDI-MS na mesma superfície, adaptada a placa do MALDI por meio de uma fita dupla face. Em outras circunstâncias, a amostra adsorvida em mica foi submetida a reações para caracterização e identificação das proteínas por MALDI-MS. __________________________________________________________________________________________ ABSTRACT / Aiming the development of analytical methodology oriented for rapid analysis of protein supramolecular systems, we present in this work the association between two powerful techniques for protein analysis: atomic force microscopy (AFM) and mass spectrometry (MS). The AFM-MS prospects are mainly directed to the interactome study. Atomic force microscopy is a powerful analytical technique for supramolecular systems. Among other information, it provides the system topography and enables the measurement of subunits dimensions. So, it deals about an analytical tool which provides important information regarding the quaternary protein structure, giving a track about how subunits interact to each other in molecular complexes formation. The precise molecular weight determination by mass spectrometry allows the solution of various problems related to biochemical issues, such as determining proteins primary and quaternary structure, characterization of their post-translational modifications, proteins identification and so on. Thanks to its versatility and sensitivity, mass spectrometry has been highlighting as an indispensable analytical tool for protein analysis. This work suggests the association of atomic force microscope and mass spectrometry for rapid analysis of a single sample. We identified the aspects in which these techniques are complementary for investigation of protein systems. For the first time, proteins adsorbed onto mica surface (support often used in AFM analysis) were identified by MALDI-MS, after having their topography examined by AFM. Samples adsorbed on mica were also subjected to reactions for protein characterization and identification by MALDI-MS.
59

Avaliação da transcrição, expressão e indução de genes que codificam peptídeos antimicrobianos em Hypsiboas raniceps por ferramentas de biologia molecular e espectrometria de massa

Barbosa, Eder Alves 02 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Biológicas, Departamento de Biologia Celular, 2010. / Submitted by Fernanda Weschenfelder (nandaweschenfelder@gmail.com) on 2010-11-16T17:45:46Z No. of bitstreams: 1 2010_EderAlvesBarbosa.pdf: 2016959 bytes, checksum: d0a01e4a8d5a19d2073a2e7c900a90a8 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-11-16T22:59:58Z (GMT) No. of bitstreams: 1 2010_EderAlvesBarbosa.pdf: 2016959 bytes, checksum: d0a01e4a8d5a19d2073a2e7c900a90a8 (MD5) / Made available in DSpace on 2010-11-16T22:59:58Z (GMT). No. of bitstreams: 1 2010_EderAlvesBarbosa.pdf: 2016959 bytes, checksum: d0a01e4a8d5a19d2073a2e7c900a90a8 (MD5) / O presente trabalho descreve um modelo experimental que permite avaliar as alterações nos níveis de transcrição de RNAs, síntese e processamento de peptídeos presentes nas secreções cutâneas de anfíbios. A partir deste modelo, foram utilizadas ferramentas de biologia molecular em associação com técnicas de obtenção de imagens moleculares por espectrometria de massa, com o objetivo de avaliar como Hypsiboas raniceps reage a um modelo experimental no qual anfíbios são submetidos a diferentes tipos de estresses (bióticos e abióticos). A utilização das técnicas de biologia molecular conjugadas a imagens de íons moleculares por espectrometria de massa permitiu as análises dos níveis de transcrição de diversos genes, assim como da síntese dos peptídeos codificados a partir destes, em uma mesma região do tecido animal. Os resultados sugerem que a aplicação do estímulo elétrico (estresse abiótico) promove um aumento imediato dos níveis de transcrição dos genes e seus respectivos peptídeos antimicrobianos em H. raniceps o qual se estende por até 36 horas, período no qual as glândulas granulares tornam-se carregadas de peptídeos novamente e os níveis de transcrição voltam a diminuir. De forma análoga aos dados anteriores, a presença de micro-organismos (Estresse biótico) na pele de H. raniceps parece estimular o sistema imune inato de defesa ao promover o aumento dos níveis de transcrição dos genes que codificam peptídeos antimicrobianos. Sob condições experimentais complementares às anteriores, anfíbios submetidos ao contato tópico com os antibióticos, oxacilina, gentamicina e ampicilina, apresentaram níveis de expressão gênica superiores àqueles dos anfíbios que foram expostos unicamente a micro-organismos. O modelo experimental proposto apresenta-se como uma estratégia alternativa para estudos de análise da expressão diferencial de peptídeos em tecidos biológicos. _________________________________________________________________________________ ABSTRACT / The present work describes a strategy for in situ identification of antimicrobial peptides present in frog skin, their respective RNA transcription levels and peptide synthesis variation analysis. The chosen experimental model is based on molecular biology and imaging mass spectrometry (IMS) techniques to investigate the antimicrobial peptide skin composition of Hypsiboas raniceps when the anuran is submitted to biotic and abiotic stress. Under a mild electrical shock stimulation high transcriptional levels of RNA encoding antimicrobial peptides can be observed for 36 hours, only after that antimicrobial peptides ions are detected by IMS experiments whereas the transcriptional levels decrease. When the animals are exposed to pathogenic microorganisms (biotic stress) there is an evident increase in gene expression levels leading to a corresponding increment on antimicrobial polypeptide content in the skin. In a complementary experiment, frogs were washed with an antibiotic solution, containing oxacillin, gentamicin and ampicilin. Under this conditions superior RNA expressions levels than the previous experiments were observed suggesting that the microorganism-based molecules that composed the antibiotic solution may have triggered the defense mechanism more efficiently. The experimental model introduced here represents an alternative strategy for differential gene expression analysis and peptides identification directly on biological tissue.
60

Produção de padrões para análise espectrométrica por emissão óptica de uma liga de aço AISI/SAE 1020

Brehm, Feliciane Andrade January 1999 (has links)
A composição química dos aços é de fundamental importância para suas propriedades mecânico-metalúrgicas. Durante o processo de fabricação de ligas metálicas, faz-se normalmente uso do espectrômetro de emissão óptica para a determinação da composição química. Este equipamento é capaz de fornecer uma análise multielementar em um intervalo de tempo muito pequeno, permitindo, assim, possíveis correções necessárias para obtenção da composição química final desejada antes do vazamento. Esta ferramenta tem como princípio de funcionamento a análise comparativa, necessitando de materiais de referência, também chamados padrões, para sua recalibração. A principal característica destes materiais de referência é sua homogeneidade em termos de composição química e física. O presente trabalho tem a finalidade de analisar a metodologia adotada para produzir padrão de referência de um aço AISI/SAE 1020 através de um programa interlaboratorial. As amostras foram obtidas por meio de um tarugo proveniente de um processo de lingotamento contínuo, que foi tratado termo-mecanicamente por processos de laminação, forjamento e usinagem antes da obtenção das amostras propriamente ditas. Após uma análise prévia da superfície das amostras, estas foram distribuídas aos integrantes do grupo analítico e analisadas nos espectrômetros de emissão óptica existentes nos seus próprios laboratórios. Foi realizada, ainda, uma análise metalográfica da superfície das amostras para que fosse verificada a homogeneidade microestrutural das amostras. O tratamento estatístico dos dados, baseado na norma ISO Guide 35, e a análise metalográfica comprovam que é possível certificar tecnicamente os teores dos elementos carbono, silício, manganês, fósforo, enxofre, cromo, níquel, molibdênio, alumínio, estanho e cobre nos materiais de referência. / The chemical composition of steel is extremely important for its mechanical and metallurgical properties. During the processing of metallic alloys, an optical emission spectrometer is used to determine the chemical composition. This equipment is able to give a multielementar analysis in a very short time interval, enabling corrections that may be necessary to obtain the final chemical composition of the casting. The working principle of this tool is the comparative analysis that needs standards, also called reference materials for its calibration. The main characteristic of these reference materials is their homogeneity in terms of physical and chemical properties. The present work aims to analyze the methodology adopted to produce the reference pattern of an AISI/SAE 1020 steel, through an interlaboratorial program. The samples were obtained from billets, which were produced via continuous casting process. Before obtaining samples the billets passed through rolling, forging and machining processes. After a previous analysis of the sample surface, the samples were distributed to the members of the analytical group, who analyzed them on the optical emission spectrometers from their own laboratories. Furthermore, a microstructure analysis of the sample surface was carried out to verify the microstructural homogeneity of the samples. The data statistic treatment, based on the ISO Guide 35 standard, and the microstructure analysis prove that it is possible to certify, technically, the content of the elements carbon, silicon, manganese, phosphorous, sulfur, chromium, nickel, molybdenum, aluminum, tin, copper in the reference materials.

Page generated in 0.0675 seconds