• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 162
  • 1
  • Tagged with
  • 165
  • 108
  • 42
  • 33
  • 32
  • 30
  • 29
  • 27
  • 24
  • 21
  • 20
  • 19
  • 18
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Estudo comparativo entre ultra-sonografia com Doppler colorido, angiografia por ressonância magnética, por subtração digital 2D e 3D na doença dos vasos carotídeos cervicais / A comparative study of Doppler ultrasound, magnetic resonance angiography, 2D and 3D digital subtraction angiography in cervical carotid stenoocclusive disease

Barros, Cristiano Ventorim de 02 October 2009 (has links)
INTRODUÇÃO: Os métodos diagnósticos não invasivos, como a ultra-sonografia com Doppler colorido (USDC) e a angiografia por ressonância magnética contrastada (ARMC) têm sido cada vez mais utilizados para o estudo da estenose das artérias carótidas internas (ACI). Nos testes comparativos a arteriografia por subtração digital bidimensional (ASD 2D) tem sido o padrão de referência, porém é um método caro, invasivo e com diversas complicações descritas, além disso, com a realização da arteriografia por subtração digital rotacional (ASD 3D), começou a se interrogar se a ASD 2D não estaria subestimando as estenoses. OBJETIVOS: Comparar as medidas de estenose obtidas pelos métodos não invasivos com a ASD 2D e 3D, utilizando o critério do North American Symptomatic Carotid Endarterectomy Trial (NASCET), além de comparar os dois métodos invasivos entre si, tentando identificar se os métodos não invasivos podem substituir a ASD 2D na rotina e se a ASD 2D tende subestimar a estenose em relação a ASD 3D. MÉTODOS: 92 pacientes que haviam sido indicados de maneira prospectiva e consecutiva para realização da ASD 2D, foram selecionados para o estudo, sendo encaminhados para realizar também a ASD 3D, a ARMC e o USDC. Os resultados das medidas da maior estenose, realizadas através das imagens fonte em estação de trabalho, por dois observadores em consenso, obtidas em cada um dos testes (USDC, ARMC) e dos resultados concordantes dos dois, foi comparada com os exames de referência (ASD 2D e ASD 3D). Foi feita também uma avaliação dos resultados dos exames invasivos entre si. RESULTADOS: 98 ACI foram incluídas no trabalho. Os resultados obtidos pelo coeficiente de correlação de Pearson e pelo coeficiente de correlação intraclasse, que variaram de 0,91 a 0,96, demonstraram respectivamente uma excelente correlação entre as modalidades diagnósticas e que há uma forte concordância entre os seus resultados (ambos com p <0,001). Os valores de sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia das diversas comparações variaram respectivamente de 76 a 100%, de 92 a 100%, 79 a 100%, 90 a 100% e 90 a 100%. DISCUSSÃO: As comparações com maior sensibilidade, especificidade e acurácia foram respectivamente a (USDC+ARMC) x ASD 3D com 100%, 100% e 100%; ARMC x ASD 3D com 100%, 96% e 97% e ASD 2D x ASD 3D, com 89%, 94% e 93%. A ASD 2D categorizou as estenoses em 11 casos (11,3%) uma classe abaixo das obtidas na ASD 3D, além de classificar 4 estenoses a menos que a ASD 3D na classe de 70-94%. CONCLUSÕES: Os métodos não invasivos principalmente se avaliados em conjunto podem substituir a ASD 2D na avaliação da estenose da ACI. A ASD 2D tendeu a subestimar levemente as estenoses quando comparada com a ASD 3D / INTRODUCTION: Noninvasive techniques such as Doppler ultrasound (DUS) and contrast enhanced magnetic resonance angiography (CEMRA) are each day more used in the evaluation of the internal carotid arteries (ICA). On comparison studies 2D digital subtraction angiography (2D DSA) has been considerate as the reference standard, however its an expensive and invasive method, with well known risks, besides the use of 3D digital subtraction angiography (3D DSA) showed that 2D DSA can potentially result in an underestimation of the stenosis. OBJECTIVES: Compare stenosis measurements of noninvasive methods with 2D and 3D DSA, using the North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria, compare the two noninvasive methods with each other, trying to identify if they can substitute 2D DSA on the daily basis and if that 2D DSA tends to underestimate the stenosis compared with 3D DSA. METHODS: 92 patients that were prospective and consecutive scheduled for 2D DSA were selected to participate in the study which included perform also a 3D DSA, CEMRA and DUS. The measurements of the greatest stenosis, made with the raw images in a workstation, by two observers in consensus, obtained with each modality (DUS, CEMRA) and the concordant results of both, were compared with the reference standard (2D and 3D DSA). Also a comparison between the invasive methods was made. RESULTS: 98 ICA were included. The results obtained by Pearson correlation coefficient and intraclass correlation coefficient, that range from 0.91 and 0.96, showed respectively a excellent correlation between the diagnostic modalities and that there are a great agreement between them (both with p<0.001). Sensitivity, specificity, positive and negative predictive values, and accuracy values of the different comparisons range respectively from 76% to 100%, 92 to 100%, 79 to 100%, 90 to 100% and 90 to 100%. DISCUSSION: Comparisons with higher sensitivity, specificity and accuracy were respectively (DUS+CEMRA) x 3D DSA, with 100%, 100% and 100%; CEMRA x 3D DSA with 100%, 96% and 97% and 2D DSA x 3D DSA with 89%, 94% and 93%. 2D DSA categorized 11 cases (11,3%) of ICA stenosis as one category lower than 3D DSA, including 4 less cases of the 70-94% class. CONCLUSIONS: The noninvasive methods, especially if evaluated together, can replace 2D DSA in the study of cervical carotid steno-occlusive disease. 2D DSA tends to lightly underestimate carotid stenosis when compared to 3D DSA
152

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Pinto, Nathali Cordeiro 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy
153

Avaliação de endoprótese nacional em traquéia de coelhos. / Auto-expansible endoprosthesis. Biocompatibility in rabbits trachea.

Faria, Celso Murilo Nálio Matias de 22 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:38Z (GMT). No. of bitstreams: 1 celsomurilonmdefaria_dissert.pdf: 1426679 bytes, checksum: 62fc4b90d691c716aef67c9e6590368e (MD5) Previous issue date: 2011-11-22 / Introduction: the utilization of endoprosthesis has its main indication in the neoplasic obstructions do not surgically treatable. The foreign industry dependence is one of the barriers we found for the broad utilization of such devices. The relevance of this research is the development of a national prosthesis from easy access and low cost. Objective: to assess the biocompatibility of nitinol endoprosthesis with polyurethane in the rabbits trachea. Material and Method: Seventeen rabbits were studied from the New Zealand breed (Oryctolagus Sylvilagus), eight male and five female, with an average weight of 3255g (from 2570 to 4270g). The endoprosthesis were applied orally through laringoscopy, under general anesthesia and released in the middle third of the trachea. Radiological study was made to assure the placement of the endoprosthesis that allowed to compare the index of migration of the endoprosthesis in millimeters. The proposed time segment was 30 days. The microscopic variables study was proceeded: dilatation, incorporation and granolomatous tissue and histological cuts from the tracheal and lungs segments for microscopic study. The histological study measured the inflammatory process, the parietal alterations and the kind of epithelium observed in the tracheal bed. Results: Thirteen animals were included in the final study. The average segment time was 26 days (15 to 35 days in observation). Six animals underwent a radiological study during euthanasia and it was demonstrated displacement with migration of the prosthesis for the distal trachea in five animals. There was absence in one. It was shown the prosthesis had a complete expansion in seven animals and partial expansion in six. The incorporation of prosthesis in the tracheal lumen was observed in two animals and adhered in eleven. Granulomatous tissue was present in ten animals and absent in three. The histological study of the mucosa and submucosa showed inflammatory process predominantly of Polymorphonuclear cells as in the contact region with the prosthesis as in the proximal. The depth of the inflammatory process in the tracheal wall was larger in the tracheal area in contact with the prosthesis. The alterations of the respiratory epithelium: the metaplasia parameter was the most frequent in the area without contact with the prosthesis. Corrosion and ulceration were predominant in the area in contact with the prosthesis. The metaplasia parameter was the most frequent in the area in contact with the prosthesis. Conclusion: the nitinol endoprosthesis auto-expandable covered with polyurethane, produced by Braile Biomédica and implanted in the trachea of rabbits was easy to apply and liberation in the tracheal lumen. The endoprosthesis recovered with polyurethane showed in radiographic assessment distal migration, good radial expandability and formation of granuloma tissue. It was also observed an inflammatory process predominantly acute and restricted to the superficial portions of the trachea. The most frequent epithelium alterations in contact with the prosthesis were ulceration and regenerative hyperplasia. / Introdução: a utilização de endoprótese tem a principal indicação nas obstruções neoplásicas e nas obstruções não tratáveis cirurgicamente. A dependência da indústria estrangeira é uma das barreiras para utilização ampla destes dispositivos. A relevância deste trabalho é o desenvolvimento de uma prótese nacional de fácil acesso e baixo custo. Objetivo: avaliar endoprótese de nitinol revestida com poliuretano, na traqueia de coelhos. Material e Método: foram estudados 17 coelhos, da raça Nova Zelândia (Oryctolagus Cuniculus). Oito machos e nove fêmeas, com peso médio de 3522g (de 2570 a 4270g). As endopróteses foram aplicadas via oral, por meio de laringoscopia, sob anestesia geral, e liberadas no terço médio das traqueias. Realizou-se estudo radiológico para assegurar a posição da endoprótese que permitiu comparar o índice de migração da endoprótese em milímetros. O tempo proposto de seguimento foi de 30 dias. Procedeu-se ao estudo das variáveis macroscópicas: dilatação, incorporação e tecido de granulação e cortes histológicos dos segmentos traqueais e pulmonares para estudo microscópico. O estudo histológico mensurou o processo inflamatório, as alterações parietais e o tipo de epitélio observado no leito traqueal. Resultados: 13 animais foram incluídos no estudo definitivo. O tempo médio de seguimento foi 26 (15 a 35) dias em observação. Em seis animais submetidos a estudo radiológico por ocasião da eutanásia, demonstrou-se deslocamento com migração da prótese para traqueia distal, em cinco; ausência de migração em um. Demonstrou-se que a prótese tinha expansão completa em sete animais e parcial em seis. A incorporação da prótese na luz traqueal foi observada em dois animais, e aderido em 11. Tecido de granulação esteve presente em dez animais e ausente em três. O estudo histológico da mucosa e submucosa demonstrou processo inflamatório com predomínio de polimorfonucleares tanto na região em contato com a prótese quanto na proximal. A profundidade do processo inflamatório na parede traqueal foi maior na área traqueal em contato com a prótese. Das alterações do eptélio respiratório, o parâmetro metaplasia foi o mais frequente na área sem contato com a prótese. Corrosão e ulceração predominaram na área em contato com a prótese. Conclusões: A escolha do coelho no desenho do presente estudo prejudicou o resultado. Trata-se de estudo pioneiro tanto na utilização de coelho para estudo de endoprótese, quanto no desenvolvimento de endoprótese metálica autoexpansível nacional. As dificuldades foram naturais deste pioneirismo, mas prejudicaram o resultado final. A endoprótese autoexpansível de nitinol recoberta de poliuretano, produzida pela Braile Biomédica Ltda, (Brasil) e implantada na traqueia de coelhos, demonstrou-se de fácil aplicação e liberação na luz traqueal. Apresentou elevada taxa de migração, boa expansibilidade radial. Verificou-se alta frequência na formação de tecido de granulação e baixa permeabilidade. Observou-se ainda processo inflamatório predominantemente agudo e restrito ás porções superficiais da traquéia. As alterações epiteliais mais freqüentes em contato com a prótese foram ulceração e hiperplasia regenerativa.
154

Estudo comparativo entre ultra-sonografia com Doppler colorido, angiografia por ressonância magnética, por subtração digital 2D e 3D na doença dos vasos carotídeos cervicais / A comparative study of Doppler ultrasound, magnetic resonance angiography, 2D and 3D digital subtraction angiography in cervical carotid stenoocclusive disease

Cristiano Ventorim de Barros 02 October 2009 (has links)
INTRODUÇÃO: Os métodos diagnósticos não invasivos, como a ultra-sonografia com Doppler colorido (USDC) e a angiografia por ressonância magnética contrastada (ARMC) têm sido cada vez mais utilizados para o estudo da estenose das artérias carótidas internas (ACI). Nos testes comparativos a arteriografia por subtração digital bidimensional (ASD 2D) tem sido o padrão de referência, porém é um método caro, invasivo e com diversas complicações descritas, além disso, com a realização da arteriografia por subtração digital rotacional (ASD 3D), começou a se interrogar se a ASD 2D não estaria subestimando as estenoses. OBJETIVOS: Comparar as medidas de estenose obtidas pelos métodos não invasivos com a ASD 2D e 3D, utilizando o critério do North American Symptomatic Carotid Endarterectomy Trial (NASCET), além de comparar os dois métodos invasivos entre si, tentando identificar se os métodos não invasivos podem substituir a ASD 2D na rotina e se a ASD 2D tende subestimar a estenose em relação a ASD 3D. MÉTODOS: 92 pacientes que haviam sido indicados de maneira prospectiva e consecutiva para realização da ASD 2D, foram selecionados para o estudo, sendo encaminhados para realizar também a ASD 3D, a ARMC e o USDC. Os resultados das medidas da maior estenose, realizadas através das imagens fonte em estação de trabalho, por dois observadores em consenso, obtidas em cada um dos testes (USDC, ARMC) e dos resultados concordantes dos dois, foi comparada com os exames de referência (ASD 2D e ASD 3D). Foi feita também uma avaliação dos resultados dos exames invasivos entre si. RESULTADOS: 98 ACI foram incluídas no trabalho. Os resultados obtidos pelo coeficiente de correlação de Pearson e pelo coeficiente de correlação intraclasse, que variaram de 0,91 a 0,96, demonstraram respectivamente uma excelente correlação entre as modalidades diagnósticas e que há uma forte concordância entre os seus resultados (ambos com p <0,001). Os valores de sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia das diversas comparações variaram respectivamente de 76 a 100%, de 92 a 100%, 79 a 100%, 90 a 100% e 90 a 100%. DISCUSSÃO: As comparações com maior sensibilidade, especificidade e acurácia foram respectivamente a (USDC+ARMC) x ASD 3D com 100%, 100% e 100%; ARMC x ASD 3D com 100%, 96% e 97% e ASD 2D x ASD 3D, com 89%, 94% e 93%. A ASD 2D categorizou as estenoses em 11 casos (11,3%) uma classe abaixo das obtidas na ASD 3D, além de classificar 4 estenoses a menos que a ASD 3D na classe de 70-94%. CONCLUSÕES: Os métodos não invasivos principalmente se avaliados em conjunto podem substituir a ASD 2D na avaliação da estenose da ACI. A ASD 2D tendeu a subestimar levemente as estenoses quando comparada com a ASD 3D / INTRODUCTION: Noninvasive techniques such as Doppler ultrasound (DUS) and contrast enhanced magnetic resonance angiography (CEMRA) are each day more used in the evaluation of the internal carotid arteries (ICA). On comparison studies 2D digital subtraction angiography (2D DSA) has been considerate as the reference standard, however its an expensive and invasive method, with well known risks, besides the use of 3D digital subtraction angiography (3D DSA) showed that 2D DSA can potentially result in an underestimation of the stenosis. OBJECTIVES: Compare stenosis measurements of noninvasive methods with 2D and 3D DSA, using the North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria, compare the two noninvasive methods with each other, trying to identify if they can substitute 2D DSA on the daily basis and if that 2D DSA tends to underestimate the stenosis compared with 3D DSA. METHODS: 92 patients that were prospective and consecutive scheduled for 2D DSA were selected to participate in the study which included perform also a 3D DSA, CEMRA and DUS. The measurements of the greatest stenosis, made with the raw images in a workstation, by two observers in consensus, obtained with each modality (DUS, CEMRA) and the concordant results of both, were compared with the reference standard (2D and 3D DSA). Also a comparison between the invasive methods was made. RESULTS: 98 ICA were included. The results obtained by Pearson correlation coefficient and intraclass correlation coefficient, that range from 0.91 and 0.96, showed respectively a excellent correlation between the diagnostic modalities and that there are a great agreement between them (both with p<0.001). Sensitivity, specificity, positive and negative predictive values, and accuracy values of the different comparisons range respectively from 76% to 100%, 92 to 100%, 79 to 100%, 90 to 100% and 90 to 100%. DISCUSSION: Comparisons with higher sensitivity, specificity and accuracy were respectively (DUS+CEMRA) x 3D DSA, with 100%, 100% and 100%; CEMRA x 3D DSA with 100%, 96% and 97% and 2D DSA x 3D DSA with 89%, 94% and 93%. 2D DSA categorized 11 cases (11,3%) of ICA stenosis as one category lower than 3D DSA, including 4 less cases of the 70-94% class. CONCLUSIONS: The noninvasive methods, especially if evaluated together, can replace 2D DSA in the study of cervical carotid steno-occlusive disease. 2D DSA tends to lightly underestimate carotid stenosis when compared to 3D DSA
155

Acurácia da tomografia computadorizada de múltiplos detectores dual-source no diagnostico da doença arterial coronariana: revisão sistemática / Accuracy of Dual-Source Computed Tomography for the Diagnosis of Coronary Artery Disease: Systematic Review and Meta-analysis

Aline Monte de Mesquita 26 April 2010 (has links)
A Tomografia Computadorizada Dual-Source (TCDS) é uma tecnologia de imagem que permite a visualização da estenose coronária de uma maneira não-invasiva. Estudos recentes demonstraram uma alta acuracia deste teste diagnóstico, quando comparado ao padrão de referência, a angiografia coronária invasiva (ACI). O objetivo deste trabalho foi sintetizar as evidências de acurácia desta tecnologia por meio de uma revisão sistemática e uma síntese quantitativa (meta-análise) e avaliar possíveis diferenciais de acurácia relacionados aos seguintes subgrupos de pacientes: com frequência cardíaca elevada, arritmias cardíacas, escore de cálcio elevado e índice de massa corporal (IMC) elevado. Foi realizada uma busca bibliográfica nas bases de dados MEDLINE e LILACS no período de janeiro de 2000 a outubro de 2009. Foram selecionados estudos em inglês, espanhol e português que comparassem a TCDS com a ACI em pacientes com suspeita ou doença arterial coronariana (DAC) e que permitissem a extração de dados suficientes para a construção de uma tabela 2X2. Três avaliadores independentes extraíram as características dos estudos e resultados, com as divergências resolvidas por consenso. Foram incluídos 20 estudos na revisão sistemática, que utilizaram três unidades de análise: paciente, vaso e segmento arterial. Nas unidades de análises paciente, vaso e segmento arterial, os valores das sensibilidades sumárias foram respectivamente de 98% (IC de 95%, 96% a 99%), 94% (IC de 95%, 89-% a 97%) e 93% (IC de 95%, 89% a 95%) e das especificidades sumárias foram respectivamente 84% (IC de 95%, 76% a 89%), 92% (IC de 95%, 87% a 95%) e 96% (IC de 95%, 91% a 98%). Também foi avaliada a acurácia nos subgrupos de pacientes com frequência cardíaca elevada e escore de cálcio aumentado. Na análise por subgrupos de pacientes, a sensibilidade e especificidade se mantiveram altas em pacientes com frequência cardíaca elevada 93% (IC de 95%, 90% a 95%) e 98% (IC de 95%, 95% a 99%), respectivamente. Já em pacientes com elevada calcificação (> 400 unidades de agatston) a especificidade diminuiu bastante, caindo para 79% (IC de 95%, 25% a 98%). A evidência disponível aponta para uma elevada acurácia da TCDS para a detecção da estenose coronária. Entretanto, a população que mais se beneficiaria desta tecnologia população com dor torácica e risco intermediário de DAC geralmente não esteve incluída nos estudos. Foram incluídos pacientes com alta probabilidade pré-teste da doença, já que os estudos foram realizados usualmente em centros de referência, com indivíduos com indicação prévia de angiografia coronária invasiva / Dualsource computed tomography (DSCT) is an imaging technology that enables the visualization of coronary artery stenosis in a non-invasive way. Earlier studies showed high accuracy compared to conventional coronary angiography. The aims of this study were to evaluate the evidence of this technology using a meta-analytic process and its accuracy in different subgroups such as patients with high heart rates, arrhythmia, increased calcium score and high body mass index. A search of the literature in MEDLINE and LILACS was performed and articles published between January 2000 and October 2009. Studies in English, Spanish and Portuguese that compared DSCT with conventional coronary angiography performed for all patients and included sufficient data for compilation of 2 X 2 tables were included. Three investigators independently extracted the characteristics of the studies and differences were settled by consensus. Twenty studies were included in the systematic review, using three units of analysis: patient, vessels and segment. Analysis of patients, vessels and segments yielded a sensitivity of 98% (95% CI, 96% to 99%), 94% (95% CI, 89% to 97%) and 93% (95% CI, 89% to 95%) and a specificity of 84% (95% CI, 76% to 89%), 92% (95% CI, 87% to 95%) and 96% (95% CI, 91% to 98%), respectively. We also analyzed the accuracy of DSCT in subgroups of patients with high heart rate and increased calcium score. The analyses of patients subgroups demonstrated that sensitivity and specificity remained high in patients with high heart rate 93% (CI 95%, 90% to 95%) and 98% (CI 95%, 95% to 99%), respectively. In patients with increased calcium score (> 400 Agatston units) the specificity declined significantly, falling to 79% (95%, 25% to 98%). The available evidence points to a high accuracy of DSCT for the detection of coronary artery stenosis. However, the population who might benefit from this technology - individuals with chest pain and intermediate risk of coronary artery disease, CAD have not generally been included in the retrieved studies since the studies were usually conducted in reference centers where patients usually have an indication for invasive coronary angiography, and consequently a high pretest probability of CAD
156

Alterações de difusão e perfusão cerebral por RM em angioplastia carotídea com \"stent\" sob proteção cerebral por filtros / Changes in diffusion and perfusion weighted magnetic resonance imaging in carotid angioplasty with stenting under cerebral protection by filters

Antenor Tavares de Sá Júnior 09 October 2009 (has links)
INTRODUÇÃO: A angioplastia carotídea com stent (ACS) sob proteção cerebral é opção terapêutica em pacientes com estenose carotídea. Existe o risco de embolia apesar da utilização do filtro e as modificações na perfusão cerebral após tratamento da estenose carotídea não são claras. O propósito deste estudo é avaliar, após ACS sob proteção cerebral por filtros, modificações nas seqüências de RM de difusão (DWI) e perfusão (PWI), correlacionando-as com os aspectos técnicos da ACS, com as características da estenose e com dados demográficos dos pacientes. MÉTODO: Trinta e seis pacientes portadores de estenose carotídea com idade média de 72,08 anos foram submetidos a exame de RM um dia antes e até 72 horas após a ACS com filtro de proteção. Todos os pacientes eram assintomáticos após a ACS. Áreas de restrição na DWI após a ACS foram correlacionadas com aspectos demográficos, com aspectos da técnica de angioplastia e com a presença de infartos prévios por RM. Os parâmetros CBV volume sanguíneo cerebral, MTT tempo de trânsito médio e TTP tempo para o pico são empregados para análise por PWI. RESULTADOS: Na DWI, 18 de 36 (50,00%) pacientes apresentaram novos focos (NF) de restrição na DWI após ACS. Todos os NF foram clinicamente silenciosos (100%). Estes NF eram localizados em território cerebral nutrido pela artéria carótida submetida à ACS em 77,19% e menores que 10 mm em 91,53%. Os NF em território cerebral não irrigado pela artéria carótida submetida à angioplastia correspondiam a 22,81% destes. A presença de infartos cerebrais prévios na RM foi o único fator com influência no aparecimento de NF (p=0,037). Fatores demográficos e aspectos relacionados com a técnica de angioplastia não tiveram importância na gênese dos NF. Na PWI foi observada melhora nos parâmetros temporais TTP (p<0,001) e MTT (p=0,019) quando comparados de forma normalizada em relação ao território contralateral. CONCLUSÃO: Os novos focos de restrição na DWI após ACS (NF) foram mais comuns no território ipsilateral (77,19%), no entanto houve NF no território contralateral à ACS (22,81%), possivelmente, associados ao cateterismo diagnóstico. Os NF, na sua maioria, são de pequeno diâmetro (<10 mm em 91,53%). Melhora precoce na PWI, observada nos dados normalizados, foi demonstrada nos parâmetros temporais (TTP e MTT). / INTRODUCTION: Carotid angioplasty with stent (CAS) under cerebral protection is a therapeutic option in patients with carotid stenosis. There is a risk of embolism even with a filter, and changes in cerebral perfusion after treatment are not clearly understood. The purpose of this study was to evaluate changes in diffusion- (DWI) and perfusion- (PWI) weighted magnetic resonance imaging (MRI) sequences correlating them with the technical aspects of CAS, stenosis characteristics and patient demographic data. METHODS: Thirty-six carotid stenosis patients with an mean age of 72.08 years were submitted to MRI exam one day before and up to 72 hours after CAS with filter protection. All patients were asymptomatic after CAS. Areas of restriction on DWI were correlated to demographic aspects, technique of angioplasty as well the presence of previous stroke by MRI. The parameters, CBV - cerebral blood volume; MTT - mean transit time, and TTP- time to peak, are used for PWI analysis. RESULTS: Eighteen of the 36 patients (50.00%) presented new focus (NF) of restriction by DWI after CAS. All new focus were clinically silent. The NF were located in the cerebral area fed by the carotid artery submitted to CAS in 77.19% and smaller than 10mm in 91.53%. NF in cerebral area not irrigated by carotid artery submitted by angioplasty correspond to 22,81 %. The presence of previous ischemic lesion on MRI was the only factor which influenced the appearance of NF (p=0.037). Demographic factors and aspects related to angioplasty technique had no importance on NF genesis. Improvement in PWI timing parameters - TTP (p<0.001) and MTT (p=0.019) were observed in relation to the contralateral territory (normalized data). CONCLUSION: The restriction NF in the DWI after CAS are more common in the ipsilateral territory (77.19%), however there were some NF in the contralateral territory to the CAS (22.81%), possibly associated with diagnostic catheterization. Most of the NF were small in diameter (<10mm in 91.53%). Short-term improvement in PWI were demonstrated by normalized timing parameters (TTP and MTT).
157

Acurácia da tomografia computadorizada de múltiplos detectores dual-source no diagnostico da doença arterial coronariana: revisão sistemática / Accuracy of Dual-Source Computed Tomography for the Diagnosis of Coronary Artery Disease: Systematic Review and Meta-analysis

Aline Monte de Mesquita 26 April 2010 (has links)
A Tomografia Computadorizada Dual-Source (TCDS) é uma tecnologia de imagem que permite a visualização da estenose coronária de uma maneira não-invasiva. Estudos recentes demonstraram uma alta acuracia deste teste diagnóstico, quando comparado ao padrão de referência, a angiografia coronária invasiva (ACI). O objetivo deste trabalho foi sintetizar as evidências de acurácia desta tecnologia por meio de uma revisão sistemática e uma síntese quantitativa (meta-análise) e avaliar possíveis diferenciais de acurácia relacionados aos seguintes subgrupos de pacientes: com frequência cardíaca elevada, arritmias cardíacas, escore de cálcio elevado e índice de massa corporal (IMC) elevado. Foi realizada uma busca bibliográfica nas bases de dados MEDLINE e LILACS no período de janeiro de 2000 a outubro de 2009. Foram selecionados estudos em inglês, espanhol e português que comparassem a TCDS com a ACI em pacientes com suspeita ou doença arterial coronariana (DAC) e que permitissem a extração de dados suficientes para a construção de uma tabela 2X2. Três avaliadores independentes extraíram as características dos estudos e resultados, com as divergências resolvidas por consenso. Foram incluídos 20 estudos na revisão sistemática, que utilizaram três unidades de análise: paciente, vaso e segmento arterial. Nas unidades de análises paciente, vaso e segmento arterial, os valores das sensibilidades sumárias foram respectivamente de 98% (IC de 95%, 96% a 99%), 94% (IC de 95%, 89-% a 97%) e 93% (IC de 95%, 89% a 95%) e das especificidades sumárias foram respectivamente 84% (IC de 95%, 76% a 89%), 92% (IC de 95%, 87% a 95%) e 96% (IC de 95%, 91% a 98%). Também foi avaliada a acurácia nos subgrupos de pacientes com frequência cardíaca elevada e escore de cálcio aumentado. Na análise por subgrupos de pacientes, a sensibilidade e especificidade se mantiveram altas em pacientes com frequência cardíaca elevada 93% (IC de 95%, 90% a 95%) e 98% (IC de 95%, 95% a 99%), respectivamente. Já em pacientes com elevada calcificação (> 400 unidades de agatston) a especificidade diminuiu bastante, caindo para 79% (IC de 95%, 25% a 98%). A evidência disponível aponta para uma elevada acurácia da TCDS para a detecção da estenose coronária. Entretanto, a população que mais se beneficiaria desta tecnologia população com dor torácica e risco intermediário de DAC geralmente não esteve incluída nos estudos. Foram incluídos pacientes com alta probabilidade pré-teste da doença, já que os estudos foram realizados usualmente em centros de referência, com indivíduos com indicação prévia de angiografia coronária invasiva / Dualsource computed tomography (DSCT) is an imaging technology that enables the visualization of coronary artery stenosis in a non-invasive way. Earlier studies showed high accuracy compared to conventional coronary angiography. The aims of this study were to evaluate the evidence of this technology using a meta-analytic process and its accuracy in different subgroups such as patients with high heart rates, arrhythmia, increased calcium score and high body mass index. A search of the literature in MEDLINE and LILACS was performed and articles published between January 2000 and October 2009. Studies in English, Spanish and Portuguese that compared DSCT with conventional coronary angiography performed for all patients and included sufficient data for compilation of 2 X 2 tables were included. Three investigators independently extracted the characteristics of the studies and differences were settled by consensus. Twenty studies were included in the systematic review, using three units of analysis: patient, vessels and segment. Analysis of patients, vessels and segments yielded a sensitivity of 98% (95% CI, 96% to 99%), 94% (95% CI, 89% to 97%) and 93% (95% CI, 89% to 95%) and a specificity of 84% (95% CI, 76% to 89%), 92% (95% CI, 87% to 95%) and 96% (95% CI, 91% to 98%), respectively. We also analyzed the accuracy of DSCT in subgroups of patients with high heart rate and increased calcium score. The analyses of patients subgroups demonstrated that sensitivity and specificity remained high in patients with high heart rate 93% (CI 95%, 90% to 95%) and 98% (CI 95%, 95% to 99%), respectively. In patients with increased calcium score (> 400 Agatston units) the specificity declined significantly, falling to 79% (95%, 25% to 98%). The available evidence points to a high accuracy of DSCT for the detection of coronary artery stenosis. However, the population who might benefit from this technology - individuals with chest pain and intermediate risk of coronary artery disease, CAD have not generally been included in the retrieved studies since the studies were usually conducted in reference centers where patients usually have an indication for invasive coronary angiography, and consequently a high pretest probability of CAD
158

Efeito do tamoxifeno na fibrose, colágeno e expressão do transforming growth factor -B1, -B2 e -B3 na anastomose da via biliar principal deporcos

Siqueira, Orlando Hiroshi Kiono January 2017 (has links)
Submitted by Verônica Esteves (vevenesteves@gmail.com) on 2018-01-11T14:41:24Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese Orlando Siqueira.pdf: 2924925 bytes, checksum: c32bce21e6c777f33da53c373787cb05 (MD5) / Approved for entry into archive by Verônica Esteves (vevenesteves@gmail.com) on 2018-01-11T14:41:40Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese Orlando Siqueira.pdf: 2924925 bytes, checksum: c32bce21e6c777f33da53c373787cb05 (MD5) / Made available in DSpace on 2018-01-11T14:41:40Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese Orlando Siqueira.pdf: 2924925 bytes, checksum: c32bce21e6c777f33da53c373787cb05 (MD5) Previous issue date: 2017 / Universidade Federal Fluminense. Hospital Universitário Antônio Pdro / Introdução: A anastomose término-terminal no tratamento da lesão das vias biliares durante a colecistectomia laparoscópica tem sido associada à formação de estenose. O objetivo deste estudo foi investigar experimentalmente o efeito do tratamento oral com tamoxifeno (tmx) sobre a fibrose, o colágeno e o transforming growth factor TGF-β1, - β2 e - β3 na anastomose da via biliar principal de porcos. Métodos: Vinte e seis porcos foram divididos em três grupos [sham (n = 8), controle (n = 9) e tmx (n = 9)]. Os ductos biliares foram seccionados e anastomosados nos grupos controle e tmx. Tmx (40 mg / dia) foi administrado oralmente ao grupo tmx, e os animais foram eutanasiados após 60 dias. A fibrose foi analisada pela coloração com tricromo de Masson. Picrosirius red foi utilizado para quantificar o teor total de colágeno e a proporção de colágeno tipo I / III. A expressão de mRNA do TGF-β1, -β2 e - β3 foi quantificada usando a reação em cadeia da polimerase em tempo real (qRT-PCR). Resultados: Os grupos de controle e estudo apresentaram fibrose maior do que o grupo sham, e o grupo de estudo apresentou fibrose menor do que o grupo controle (p = 0,011). Os grupos controle e tmx apresentaram maior teor total de colágeno do que o grupo sham (p = 0,003) e não houve diferença significativa entre os grupos controle e tmx. A proporção de colágeno tipo I / III foi maior no grupo controle do que nos grupos sham e tmx (p = 0,015) e não houve diferença significativa entre os grupos sham e tmx. Não houve diferenças significativas na expressão de mRNA de TGF-β1, -β2 e -β3 entre os grupos (p> 0,05). Conclusões: Tmx diminuiu a fibrose e impediu a alteração na proporção de colágeno tipo I / III causada pelo procedimento. / Introduction: End-to-end anastomosis in the treatment of bile duct injury during laparoscopic cholecystectomy has been associated with the formation of stenosis. The aim of this study was to experimentally investigate the effect of oral treatment with tamoxifen (tmx) on fibrosis, collagen and transforming growth factor TGF-β1, - β2 and – β3 on anastomosis of the common bile duct in pigs. Methods: Twenty-six pigs were divided into three groups (sham (n = 8), control (n = 9) and tmx (n = 9)). The bile ducts were sectioned and anastomosed in the control and tmx groups. Tmx (40 mg / day) was administered orally to the tmx group, and the animals were euthanized after 60 days. Fibrosis was analyzed by Masson's trichrome staining. Picrosirius red was used to quantify the total collagen content and the proportion of collagen type I / III. Expression of TGF-β1, -β2 and -β3 mRNA was quantified using the real-time polymerase chain reaction (qRT-PCR). Results: The control and study groups presented higher fibrosis than the sham group, and the study group had lower fibrosis than the control group (p = 0.011). The control and tmx groups presented higher total collagen content than the sham group (p = 0.003) and there was no significant difference between the control and tmx groups. The proportion of type I / III collagen was higher in the control group than in the sham and tmx groups (p = 0.015) and there was no significant difference between the sham and tmx groups. There were no significant differences in TGF-β1, -β2 and -β3 mRNA expression between the groups (p> 0.05). Conclusions: Tmx decreased fibrosis and prevented the change in the proportion of collagen type I / III caused by the procedure.
159

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Nathali Cordeiro Pinto 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy
160

A clonidina reduz a pressão arterial pulmonar em portadores de estenose mitral

Garcia, Maria Helena Domingues 29 September 2005 (has links)
Pulmonary circulation is a high flow, low resistance, and low pressure system. Several pathologies, including mitral stenosis, may elevate the impedance of this blood circuit and lead to a pulmonary arterial hypertension. Such syndrome is usually related to a high morbity and patient s death may occur because of the ischemic failure of right ventricle. The use of systemic vasodilating drugs to treat this syndrome is limited by the simultaneous systemic arterial hypotension they often produce. More selective agents to the pulmonary vasculature, such as synthetic analogs of prostacyclin, endothelin receptor inhibitors, and phosphodiesterase III inhibitors, have been choosen for medium and long-term treatment. Unfortunately, the most selective pulmonary hypotensive agent, the inhaled nitric oxide, which is used for short-term treatment, requires special and costly equipment for its administration, making it inaccessible to many hospitals. Furthermore, some degree of toxicity was associated with that substance. The lack of an ideal substance that simultaneously shows pulmonary selectivity, atoxicity, easy handling, accessibility and low cost, motivated the present study to test the effects of clonidine on pulmonary circulation. Clonidine is an alfa-2 adrenergic agonist. It promotes a systemic cardiocirculatory balance by modulating the adrenergic discharge at both central and peripheral levels. When used in clinical doses it presents no toxicity. Furthermore, it is easy to handle, accessible, and inexpensive. However, little has been reported about its pulmonary effect. Therefore, this work aimed to evaluate the effects of clonidine on the pulmonary arterial pressure, on the hemodynamics parameters concerned to the pulmonary circulatory system, as well as on the right ventricular function. At the same time, the action of clonidine on the systemic hemodynamics, cardiac rate, cardiac index and stroke index was also evaluated. This investigation took into account the degree of selectivity of this agent to the pulmonary vessels as well as the presence of a biphasic effect on the pulmonary arterial pressure. This effect has been largely reported on the vascular periferal system. The present research was performed as a prospective clinical trial developed on a group of 16 patients with pulmonary hypertension caused by mitral stenosis of rheumatic origin. Data were obtained before the anesthetic induction, but under the patient sedation. During the control phase, the variations of hemodynamic parameters under the action of a placebo were evaluated. During the test phase, the behavior of these parameters was evaluated under the clonidine effect. The time schedule for data measurements was the following: T0 (initial control); T1 (10 minutes after placebo administration); T2 (20 minutes after placebo administration); T3 (10 minutes after clonidine administration); T4 (20 minutes after clonidine administration). T2 was used as the control time to study the clonidine effects. Statistical analysis showed that during the control phase the variables remained unchanged, but under the effect of clonidine there was a significant reduction of the mean values concerned to the following parameters: pulmonary arterial mean pressure (27.1%) and systemic arterial mean pressure (20%), pulmonary vascular resistance index (34%) and systemic vascular resistance index (14.6%), right and left ventricular systolic work indexes (19.9% and 10%, respectively), right atrium pressure (11.5%), pulmonary arterial wedge pressure (21.5%), heart rate and cardiac index (15.8% and 7.9%, respectively). Besides that, a significant increase of the stroke index (10.2%) occured. The biphasic effect on the sistemic arterial pressure occured in 50% of the studied patients, whereas the same effect on the pulmonary arterial pressure was observed in 20% of the same sample. Clonidine also exerted a moderately selective action on the pulmonary circulation, demonstrated through the reduction of the relationship between mean value of the pulmonary vascular resistance index and mean value of the systemic vascular resistance index evaluated at the times T2 and T3. / A circulação pulmonar é um sistema de alto fluxo, baixa resistência e baixa pressão. Patologias diversas, dentre elas a estenose mitral, podem elevar a impedância desse circuito, desencadeando a síndrome de hipertensão arterial pulmonar. Esta cursa com elevada morbidade, podendo levar ao óbito pela falência isquêmica do ventrículo direito. A utilização de drogas vasodilatadoras periféricas no tratamento dessa síndrome ficou limitada pela simultânea hipotensão arterial sistêmica que provoca. Agentes mais seletivos sobre a vasculatura pulmonar, como os análogos sintéticos da prostaciclina, os inibidores dos receptores de endotelina e os inibidores da fosfodiesterase III, têm sido as drogas de eleição para o tratamento de médio e de longo prazo. O mais seletivo dos agentes hipotensores pulmonares, o óxido nítrico inalado, aplicado ao tratamento de curto prazo, exige equipamento especial e oneroso para a sua administração, tornando-o inacessível a muitos nosocômios. Paralelamente, possui potencial toxicidade. A inexistência de um fármaco ideal que apresente, simultaneamente, seletividade sobre a pequena circulação, atoxicidade, fácil manuseio e disponibilidade, além de ser pouco oneroso, conduziu ao estudo da clonidina sobre a árvore circulatória pulmonar. Este agente terapêutico é um agonista alfa-2 adrenérgico, com efeitos favoráveis reconhecidos sobre o equilíbrio circulatório sistêmico por modular a descarga adrenérgica em níveis central e periférico. É atóxico quando utilizado em doses clínicas. Além disso, oferece fácil manuseio, boa acessibilidade e baixo custo. Os estudos a respeito da sua ação pulmonar são escassos. Assim, a presente investigação teve como objetivo avaliar os efeitos da clonidina sobre a pressão arterial pulmonar, sobre os demais parâmetros hemodinâmicos da pequena circulação e sobre a função ventricular direita. Paralelamente, analisou as ações sobre a hemodinâmica sistêmica, a freqüência cardíaca, o índice cardíaco e o índice de ejeção. Foi também investigado o grau de seletividade pulmonar desse agente, bem como a presença de um efeito bifásico sobre a pressão arterial pulmonar, pois este efeito tem sido amplamente relatado no sistema vascular periférico. Para a execução dos objetivos propostos, um ensaio clínico prospectivo, realizado antes da indução anestésica, mas sob sedação, foi desenvolvido num grupo de 16 pacientes, todos portadores de hipertensão pulmonar resultante de estenose mitral de origem reumática. Durante a fase controle foram analisadas as variações dos parâmetros hemodinâmicos sob a ação de um placebo. Durante a fase teste foi avaliado o comportamento dos mesmos parâmetros sob a ação da clonidina. A padronização dos tempos nos quais se fez a coleta de dados foi a seguinte: T0 (controle inicial); T1 (10 min após a administração do placebo); T2 (20 min após o placebo); T3 (10 min após a administração da clonidina); T4 (20 min após a clonidina). A análise estatística dos resultados demonstrou não haver alteração das variáveis estudadas durante a fase controle. Todavia, sob o efeito da clonidina houve variações estatisticamente significantes dos mesmos parâmetros nos seus valores médios: redução da pressão arterial pulmonar média (27,1%) e da pressão arterial sistêmica média (20%), dos índices de resistência vascular pulmonar (34%) e sistêmica (14,6%), dos índices de trabalho sistólico dos ventrículos direito (19,9%) e esquerdo (10%), da pressão do átrio direito (11,5%), da pressão de oclusão da artéria pulmonar (21,5%), da freqüência cardíaca (15,8%) e do índice cardíaco (7,9%), ao lado de uma elevação significante do índice de ejeção (10,2%). O efeito bifásico sobre a pressão arterial sistêmica ficou evidente em 50% dos pacientes estudados, enquanto que o mesmo efeito sobre a pressão arterial pulmonar ocorreu em 20% da amostra estudada. A clonidina também exerceu uma ação moderadamente seletiva sobre a circulação pulmonar, demonstrada através da diminuição do quociente obtido entre o valor médio do índice de resistência vascular pulmonar e valor médio do índice de resistência vascular sistêmica, ambos avaliados nos tempos T2 e T3.

Page generated in 0.0636 seconds