• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 162
  • 1
  • Tagged with
  • 165
  • 108
  • 42
  • 33
  • 32
  • 30
  • 29
  • 27
  • 24
  • 21
  • 20
  • 19
  • 18
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Avaliação da sensibilidade e especificidade dos exames utilizados no diagnóstico da estenose de artéria renal em prováveis portadores de hipertensão renovascular / Evaluation of sensitivity and specificity of tests used in the diagnosis of renal artery stenosis in patients probably with renovascular hypertension

Flavio Antonio de Oliveira Borelli 17 May 2012 (has links)
A crescente incidência da aterosclerose na população adulta e a obstrução da artéria renal são condições relacionadas à hipertensão renovascular. Independente das comorbidades presentes, a estenose de artéria renal é, por si só, importante causa de mortalidade cardiovascular. Frente a tal realidade, determinar o exame ou exames que possam identificar precocemente esta condição mórbida pode mudar a história natural da doença renovascular. Objetivo: Definir sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo dos exames não invasivos na estenose da artéria renal. Associar estes achados com a análise vascular quantitativa (QVA) das artérias renais. Métodos: Estudo prospectivo com 61 pacientes recrutados entre janeiro de 2008 e agosto de 2011. As características populacionais, os exames de ultrassom Doppler, cintilografia renal com DTPA e a tomografia computadorizada foram selecionados e seus resultados comparados à arteriografia digital das artérias renais e ao QVA. Resultados: A média das idades foi de 65,43 (DP 8,7) anos. Das variáveis relacionadas à população do estudo e comparadas à arteriografia, duas identificaram relação com a estenose da artéria renal, a disfunção renal e os triglicerídeos. A mediana do ritmo de filtração glomerular de 52,8 ml/min/m2 identificou uma razão de chance para estenose de artéria renal de até 10 vezes. Os triglicerídeos associaram-se a uma menor presença de estenose na artéria renal, p < 0,037. A análise da sensibilidade, especificidade, valor preditivo positivo e negativo dos diferentes testes diagnósticos permitiu identificar aquele que melhor detectava a estenose nos suspeitos e afastava nos sadios. O ultrassom doppler com sensibilidade de 82,90%, especificidade 70,00%, valor preditivo positivo 85,00% e preditivo negativo 66,70% e a angiotomografia com sensibilidade de 68,30%, especificidade 80,00%, valor preditivo positivo 87,50% preditivo negativo de 55,20%, foram os exames que permitiram predizer as maiores chances de estenose da artéria renal nos portadores e afastar na população sem estenose. A associação das características populacionais com o QVA, permitiu identificar duas novas variáveis, o sexo e a idade. A média do grau de estenose, 33,47% (DP 29,55) quantificada pelo QVA, identificou menores graus de estenose que na análise visual dos angiogramas. Exames não invasivos positivos em estenoses menores do que 60% da luz do vaso também foram identificados . Os resultados identificados pela curva ROC demonstraram respectivamente a arteriografia, a angiotomografia e o ultrassom Doppler como os exames com melhores chances em predizer estenose significativa da artéria renal. Conclusão: A angiotomografia e o ultrassom Doppler trouxeram qualidade e alta possibilidade no diagnóstico da estenose da artéria renal, com vantagem para o segundo, pois não há necessidade do uso de meio de contraste na avaliação de uma doença que, frequentemente, está acompanhada por portadores de disfunção renal, disfunção ventricular esquerda grave e diabetes melito. A incorporação de uma forma objetiva de medidas das artérias renais aprimora os resultados da angiografia invasiva. / The increasing incidence of atherosclerosis in adults and renal artery stenosis are conditions related to renovascular hypertension. Regardless all risk factors, renovascular stenosis is by itself an important cause of cardiovascular mortality. Choosing appropriate tests that can early identify this morbid condition can change the natural history of renovascular disease. Objective: To define sensitivity, specificity, positive and negative predictive value of non- invasive tests in renal artery stenosis. Associate these findings with the renal arteries quantitative vascular analysis (QVA). Methods: Prospective study with 61 patients selected between January 2008 and August 2011. The population characteristics, Doppler ultrasound scanning, DTPA renal scintigraphy and computed tomography were selected and their results compared with renal arteries digital angiography as well as the comparison to QVA. Results: The mean age was 65.43 (SD 8.7). The risk factors of the study population compared to angiography identified two variables: renal dysfunction and triglycerides. The median glomerular filtration rate of 52.8 ml/min/m2 identified an odds ratio for renal artery stenosis up to 10 times. Triglycerides were associated with lower presence of renal artery stenosis p < 0.037. The analysis of sensitivity, specificity, positive and negative predictive values of different diagnostic tests allowed the identification of the stenosis in the group of suspected patients and this possibility was discarded in the group of healthy patients. Doppler ultrasound scanning with 82.90% sensitivity, 70.00% specificity, 85.00% positive predictive value, 66.70% negative predictive value and computed tomography with 68.30% sensitivity, 80.00% specificity, 87.50% positive predictive value and 55.20% negative predictive value. These were the tests which supplied better chances to predict renal artery stenosis in patients with or without stenosis. The relationship of population characteristics with QVA identified two new variables, gender and age. The mean degree of stenosis 33.47% (SD 29.55) quantified by QVA identified lesser degrees of stenosis than in visual analysis of angiograms. Non- invasive positive stenoses less than 60% of vessel lumen were identified. The results identified by the ROC curve showed respectively angiography, computed tomography, and Doppler ultrasound scanning as better chances for predicting renal artery stenosis. Conclusion: Computed tomography, Doppler ultrasound scanning have brought high quality and ability in the diagnosis of renal artery stenosis, with an advantage to Doppler, which avoids the use of contrast medium in the evaluation of a disease that is often accompanied by patients with renal dysfunction, severe left ventricular dysfunction and diabetes mellitus. The introduction of new methodology to measure renal arteries will certainly improve the angiography results.
142

Medida do strain bidimensional do ventrículo esquerdo pré-implante percutâneo de endoprótese valvar aórtica: correlação com a evolução após o procedimento / Measurement of bidimensional strain of left ventricle before percutaneous implantation of aortic valve endoprosthesis: correlation with evolution after the procedure

Lucas Arraes de França 24 May 2017 (has links)
INTRODUÇÃO: O implante transcateter de prótese valvar aórtica (TAVI) surge nos dias atuais como uma opção terapêutica para os pacientes sintomáticos portadores de estenose aórtica grave. Cerca de 200 mil pacientes em todo o mundo já foram submetidos ao TAVI. Não há grandes estudos que tenham avaliado a correlação prognóstica entre parâmetros ecocardiográficos antes do TAVI e eventos cardiovasculares a longo prazo. É relevante analisar se o strain pré-procedimento e outros parâmetros se comportam como fatores preditores independentes de eventos após o procedimento. MÉTODOS: Foram avaliados, de novembro de 2009 a outubro de 2016, 86 pacientes, submetidos a avaliação ecocardiográfica antes do TAVI e 30 dias após o procedimento, com análise do strain do ventrículo esquerdo pelo speckle tracking bidimensional e outros parâmetros ecocardiográficos. Esses pacientes foram acompanhados clinicamente e avaliados quanto aos desfechos: mortalidade global, mortalidade cardiovascular, classe funcional de insuficiência cardíaca e necessidade de reinternação cardiovascular. RESULTADOS: O strain global longitudinal pré-TAVI reduzido (valor absoluto) aumentou a chance de reinternação cardiovascular (OR: 0,87; 0,77 ±0,99; P= 0,038). A redução da relação E/e´ em 30 dias após o TAVI associou-se à queda da mortalidade global (OR: 0,97; 0,95 ±0,99; P = 0,006), bem como valores elevados pré procedimento dessa relação se associaram a maiores taxas de insuficiência cardíaca classe funcional III ou IV da New York Heart Association após a intervenção (OR: 1,08; 1±1,18; P = 0,049). CONCLUSÃO: Os resultados deste trabalho indicam que o strain global longitudinal pré-procedimento demonstrou ser um preditor de reinternação cardiovascular pós-intervenção a longo prazo. A relação E/e´ pré-procedimento apresentou correlação diretamente proporcional com o desenvolvimento de insuficiência cardíaca classe funcional III ou IV a longo prazo, assim como sua queda acentuada 30 dias após o procedimento correlacionou-se com menor mortalidade global. / INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is a therapeutic option for symptomatic patients with severe aortic stenosis. Approximately 200,000 patients around the world have already undergone TAVR. No large studies have evaluated prognostic correlation between echocardiographic parameters before TAVR and long-term cardiovascular events. It is relevant to analyze strain before procedure and how other parameters work as independent predictors of events after the procedure. METHODS: A total of 86 patients were evaluated from November 2009 to October 2016. They underwent echocardiographic evaluation before TAVR and 30 days after the procedure with analysis of strain of the left ventricle by bidimensional speckle tracking and other echocardiographic parameters. Patients were followed clinically and evaluated in relation to outcomes: global mortality, cardiovascular mortality, functional class of heart failure and need for cardiovascular readmissions. RESULTS: Global longitudinal strain before reduced TAVR (absolute value) increased the chance of cardiovascular readmission (odds ratio: 0.87; 0.77 ± 0.99; p = 0.038). Reduction of E/e´ relationship 30 days after TAVI was associated with a drop in global mortality (odds ratio: 0.97; 0.95 ± 0.99; p = 0.006). In addition, high values for this relation before the procedure were associated with higher rates of New York Heart Association functional class III or IV heart failure after the intervention (odds ratio: 1.08; 1.00 ± 1.18; p = 0.049). CONCLUSIONS: Results of this study indicate that global longitudinal strain before the procedure is a predictor of cardiovascular readmission after TAVR. The E/e´relationship before the procedure presented a correlation directly proportional to the development of long-term functional class III or IV heart failure as well as its accentuated drop 30 days after the procedure was correlated with lower global mortality.
143

Estudo randomizado comparativo entre duas técnicas de proteção embólica cerebral no tratamento endovascular das estenoses carotídeas / Flow-­reversal versus filter protection: a pilot carotid artery stenting randomized trial

Luís Henrique de Castro Afonso 04 September 2014 (has links)
O acidente vascular cerebral (AVC) e a primeira causa de obito no Brasil e a principal de incapacidade no mundo. A doenca aterosclerotica carotidea esta associada a cerca de 15% dos AVC. A endarterectomia cirurgica e o tratamento padrao-­ouro para as estenoses carotideas sintomaticas. A angioplastia carotidea com stent via endovascular (ACS) e uma alternativa terapeutica a endarterectomia. O desenvolvimento de dispositivos de protecao embolica levou a reducao das taxas de complicacao durante a ACS. A tecnica de protecao mais utilizada na pratica clinica e a protecao distal com filtro. As estrategias de protecao proximal, por bloqueio ou reversao do fluxo carotideo, tem revelado resultados promissores em relacao a protecao distal com filtro durante a ACS. Assim, o objetivo do estudo foi comparar a reversao de fluxo e o filtro de protecao durante a ACS. Os objetivos primarios foram a incidencia, o numero e o tamanho das lesoes cerebrais isquemicas por ressonancia magnetica pela sequencia diffusion-­weighted-­imaging (DWI) apos a ACS. Os objetivos secundarios foram as complicacoes cardiacas e eventos cerebrovasculares (CCEC), ataque isquemico transitorio (AIT) e as lesoes cerebrais isquemicas definitivas na imagem por ressonancia magnetica pela sequencia fluid-­attenuated inversion recovery (FLAIR) no seguimento de tres meses. As lesoes isquemicas foram obtidas por ressonancia magnetica (RM) de campo 3 Tesla. Os pacientes foram avaliados quanto aos desfechos neurologicos atraves das escalas do National Institutes of Health Stroke Scale (NIHSS) e modified Rankin Scale (mRS). Quarenta pacientes foram incluidos randomicamente no estudo. Comparado a reversao de fluxo (n=21) o filtro de protecao (n=19) resultou em uma reducao significativa na incidencia (15,8% vs. 47,6%, p=0,03), no numero (0,73 vs. 2,6, p=0,05) e no tamanho (0,81 vs. 2,23 mm, p=0,05) das novas lesoes cerebrais isquemicas. Dois pacientes, um de cada grupo, apresentaram AIT no seguimento de tres meses. Nao foram observadas CCEC na internacao ou no seguimento de tres meses. Neste estudo, o filtro de protecao mais eficaz que a reversao de fluxo na protecao cerebral durante a angioplastia carotidea com stent por acesso femoral. / Objectives: Carotid artery stenting (CAS) has become an alternative treatment for patients presenting symptomatic carotid artery stenosis. The improvement in clinical outcomes with CAS has been associated with the development of embolic protection devices. The trial aim is to compare flow-­reversal versus filter protection during CAS through femoral access. Methods: Patients were randomly enrolled in CAS using flow-­reversal or filter protection. The primary endpoints were the incidence, number and size of new ischemic brain lesions after CAS. The secondary endpoints included major adverse cardiac and cerebrovascular events (MACCE), transient ischemic attack (TIA) and definitive ischemic brain lesions on fluid-­attenuated inversion recovery magnetic resonance image (FLAIR-­MRI) at a three-­month follow-­up. Ischemic brain lesions were assessed by a 3T-­MRI. Neurological outcomes were evaluated by means of the National Institutes of Health Stroke Scale (NIHSS) and the modified Rankin Scale (mRS). Results: Forty consecutive patients were randomly assigned. Compared to flow-­reversal (n=21), filter protection (n=19) resulted in a significant reduction in the incidence (15.8% vs. 47.6%, p=0.03), number (0.73 vs. 2.6, p=0.05) and size (0.81 vs. 2.23 mm, p=0.05) of new ischemic brain lesions. Two patients, one from each group, presented TIA at the three-­month follow-­up. There were no MACCE in the hospital or at the three-­month follow-­up. Conclusions: In this small sample size trial, filter protection was more effective than flow-­reversal in reducing ischemic brain lesions during CAS through femoral approach.
144

Custo direto do implante por cateter de bioprótese valvar aórtica nas diferentes vias de acesso / Direct cost of transcatheter aortic valve implantation in the different access routes

Eliana Bittar 31 March 2017 (has links)
Introdução: Uma nova alternativa de tratamento foi desenvolvida, o Implante por Cateter de Bioprótese Valvar Aórtica (TAVI, em inglês, Transcatheter Aortic Valve Implantation), indicado para os pacientes portadores de estenose aórtica grave com várias comorbidades, considerados inoperáveis pelo tratamento cirúrgico convencional. O TAVI ainda não foi incorporado ao rol de políticas de saúde do Brasil pelo Sistema Único de Saúde (SUS), tampouco pela Agência Nacional de Saúde Suplementar (ANS), pois há escassez de evidências científicas fundamentadas em análise econômica do procedimento que relatem os resultados e o custo a longo prazo em comparação à cirurgia convencional. Objetivo: Identificar o custo direto médio do implante por cateter de bioprótese valvar aórtica, verificar se há alteração significativa de custo nas diferentes vias de acesso utilizadas e identificar os fatores preditores que possam elevar o custo do procedimento. Método: Trata-se de uma pesquisa com abordagens quantitativa, exploratória, descritiva, transversal, retrospectiva e documental, realizada em um hospital da Secretaria de Estado de Saúde de São Paulo (SES-SP), da Administração Direta, especializado no tratamento de doenças cardiovasculares de alta complexidade. A população do estudo correspondeu aos procedimentos eletivos do TAVI, desde a inauguração da sala híbrida, em março de 2012, até agosto de 2015, totalizando 108 procedimentos, sendo 92 por via transfemoral, 8 por via transapical e 8 por via transaórtica. Resultados: O custo direto médio dos procedimentos TAVI nas três vias totalizou R$ 82.230,94. Por via transfemoral, esse custo médio foi de R$ 82.826,38; por via transaórtica, R$ 79.440,91; e por via transapical, R$ 78.173,41. O total de material e medicamento/solução representou, por via transfemoral, 91,89% do total do custo direto médio do procedimento TAVI; por via transapical, 91,81%; e por via transaórtica, 90,69%, e o custo fixo com a válvula transcateter, no valor de R$ 65 mil, representou 78,47% sobre o custo total do procedimento TAVI, por via transfemoral; 83,14%, por via transapical; e 81,82%, por via transaórtica. O Teste Kruskal-Wallis Teste das Variáveis Contínuas apresentou diferença estatisticamente significativa entre as vias de acesso. No custo total do procedimento TAVI, o Teste de Bonferroni mostrou diferença na associação entre as vias transfemoral e transapical. No entanto, na associação com a via transaórtica, não apresentou diferença estatisticamente significativa. Os fatores preditores que elevaram o custo do procedimento TAVI foram: vias de acesso, duração do procedimento, material de hemodinâmica, medicamento/solução, material de consumo, material de perfusão, total de material e medicamento/solução, recursos humanos, gases medicinais, depreciação e energia. A segunda válvula foi a única variável referente às intercorrências no Centro Cirúrgico que elevou o custo do procedimento. A média de idade dos pacientes com indicação ao TAVI foi de 81,50 ±6,96 anos. Conclusão: O TAVI é um avanço a ser discutido e acompanhado, havendo a necessidade de reforçar novas pesquisas que avaliem os benefícios do tratamento com base nos resultados e custos, a fim de auxiliar na tomada de decisão para incorporação desse tratamento para o público-alvo, melhorando a qualidade de vida dos pacientes e proporcionando a integração destes novamente às atividades diárias. / Introduction: A new treatment alternative has been developed, the Transcatheter Aortic Valve Implantation (TAVI), indicated for patients with severe aortic stenosis with various comorbidities deemed inoperable by conventional surgical treatment. TAVI has not yet been incorporated into the Brazilian health policies by the Public Health System (SUS), or by the National Supplementary Health Agency (ANS), because there is a shortage of scientific evidence based on an economic analysis of the procedure that reports the results and the long-term costs compared to conventional surgery. Objective: To identify the average direct cost of the transcatheter aortic valve implantation, to verify if there is significant change of cost in the different access routes used, and to identify predictive factors that could increase the cost of the procedure. Method: This is a study with quantitative, exploratory, descriptive, transversal, retrospective, and documentary approaches, carried out in a hospital of the State Department of Health of São Paulo (SES-SP), of the Direct Administration, specialized in the treatment of high-complexity cardiovascular diseases. The study population corresponded to TAVI elective procedures, from the inauguration of the hybrid room, in March 2012, up to August 2015, totaling 108 procedures, of which 92 were transfemoral, 8 were transapical, and 8 were transaortic. Results: The average direct cost of the TAVI procedures in the three routes totaled R$ 82,230.94. Transfemorally, this average cost was R$ 82,826.38; through the transaortic route, R$ 79,440.91; and through the transapical route, R$ 78,173.41. The total material and medication / solution represented 91.89% of the total average direct cost of the TAVI procedure through the transfemoral route; 91.81% through the transapical route; and 90.69% through the transaortic route, and the fixed cost with the transcatheter valve, in the amount of R$ 65,000.00, represented 78.47% of the total cost of the TAVI procedure through the transfemoral route; 83.14%, through the transapical route; and 81.82% through the transaortic route. The Kruskal-Wallis Test Continuous Variables Test showed a statistically significant difference among the access routes. In the total cost of the TAVI procedure, the Bonferroni Test showed a difference in the association between the transfemoral and transapical routes. However, in the association with the transaortic route, there was no statistically significant difference. Predictive factors that increased the cost of the TAVI procedure were: access routes, length of procedure, hemodynamic material, drug / solution, consumption material, infusion material, total material and medicine/solution, human resources, medical gas, depreciation and energy. The second valve was the only variable related to the complications in the or that increased the cost of the procedure. The mean age of patients with TAVI was 81.50 ± 6.96 years. Conclusion: TAVI is an advance to be discussed and monitored, and there is a need to encourage new studies that evaluate the benefits of treatment based on the results and costs, in order to assist in the decision making for the incorporation of this treatment into its population, improving the quality of life of patients and providing once again their integration into daily activities.
145

Análise da aplicabilidade da técnica NIRS ao estudo da atividade cerebral sob três condições distintas : estimulação visual, realização de exercícios físicos e apneia induzida em pacientes com estenose carotídea / Analysis of the applicability of the NIRS technique to the study of brain activity under three different conditions: visual stimulation, practice of physical exercices and induced apnea in patients with carotid stenosis

Anjos, Carlos Alessandro Silva dos, 1978- 11 May 2014 (has links)
Orientadores: Roberto José Maria Covolan, Rickson Coelho Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-25T21:27:17Z (GMT). No. of bitstreams: 1 Anjos_CarlosAlessandroSilvados_D.pdf: 14228439 bytes, checksum: 3f8ec7a93c1a21bbd6147d80351b5c9b (MD5) Previous issue date: 2014 / Resumo: A atividade cerebral envolve uma complexa rede de processos neurofisiológicos cuja demanda energética requer constante aporte de glicose e oxigênio, supridos através da microcirculação sanguínea cerebral. Variações na circulação sanguínea cerebral decorrentes de ativação neuronal podem ser detectadas e registradas através da técnica óptica denominada NIRS (near infrared spectroscopy). Neste trabalho, desenvolvemos estudos sobre a aplicabilidade da técnica NIRS sob três diferentes abordagens, envolvendo indivíduos saudáveis e portadores de uma condição patológica específica. Os estudos com indivíduos saudáveis foram focados na aplicabilidade da técnica NIRS para investigar alterações hemodinâmicas associadas à estimulação do córtex visual e à realização de exercício físico. No caso envolvendo condição patológica, investigamos a aplicabilidade clínica desta mesma técnica para avaliar a perfusão cerebral de pacientes com estenose carotídea. Nos estudos sobre estimulação do córtex visual, buscou-se estabelecer uma relação entre a frequência do estímulo apresentado ao voluntário e parâmetros obtidos das curvas hemodinâmicas. Nos experimentos associados a exercícios físicos, ciclistas semiprofissionais e indivíduos fisicamente ativos realizaram testes em bicicletas simulando tipos específicos de provas, envolvendo tarefas abertas (teste progressivo) e fechadas (teste contra relógio em uma prova de 4Km), em diferentes condições (controle, ingestão de placebo ou cafeína), buscando caracterizar diferenças em aspectos da hemodinâmica cerebral a elas associadas. Por fim, nos experimentos envolvendo indivíduos com estenose carotídea, foram realizadas medidas de NIRS, durante a realização de testes de apneia com duração de 30 segundos, buscando estabelecer a aplicabilidade da técnica na avaliação clínica deste tipo de patologia. Para cada uma dessas abordagens, foram estabelecidos parâmetros associados às respostas hemodinâmicas obtidas através de tarefas e estímulos específicos, que permitiram caracterizar e quantificar os processos fisiológicos envolvidos em cada tipo de experimento, demonstrando assim a aplicabilidade da técnica NIRS para o estudo da atividade cerebral sob as condições experimentais em questão / Abstract: Brain activity involves a complex network of neurophysiological processes whose energy demand requires constant supply of glucose and oxygen which is provided by the cerebral microcirculation. Changes in cerebral blood flow due to neuronal activation can be detected and recorded by the optical technique called NIRS (near infrared spectroscopy). In this work, we developed studies on the applicability of the NIRS technique under three different approaches, involving healthy subjects and patients with a specific pathological condition. Studies in healthy subjects were focused on the applicability of the NIRS technique to investigate hemodynamic changes associated with stimulation of the visual cortex and the performance of physical exercise. In the case involving pathological condition, we investigated the clinical applicability of this same technique to evaluate cerebral perfusion in patients with carotid stenosis. In studies of stimulation of the visual cortex, we sought to establish a relationship between the frequency of the stimulus presented to volunteer and parameters obtained from the hemodynamic curves. In the experiments associated with exercise, semi-professional cyclists and physically active subjects performed tasks on bicycles simulating specific types of tests, involving open tasks (progressive test) and closed (a 4km test against the clock), under different conditions (control, placebo or caffeine intake), seeking to characterize differences in aspects of cerebral hemodynamics associated with them. Finally, in experiments involving individuals with carotid stenosis, NIRS measurements were carried out during apnea tests lasting 30 seconds, from which we sought to establish the applicability of the technique in the clinical evaluation of this type of pathology. For each of these approaches, parameters associated with the hemodynamic responses obtained by stimulation of specific tasks allowed to characterize and quantify the physiological processes involved in each type of experiment, thus demonstrating the applicability of the NIRS technique to the study of brain activity under the experimental conditions in question / Doutorado / Física / Doutor em Ciências
146

Influência da doença aterosclerótica arterial coronária crítica na mortalidade hospitalar de pacientes portadores de estenose aórtica submetidos à substituição valvar / Influence of critical atherosclerotic coronary artery disease in hospital mortality of patients with aortic stenosis submitted to aortic valve replacement

José de Lima Oliveira Junior 03 September 2008 (has links)
Com o aumento da expectativa de vida nas últimas décadas, tem ocorrido aumento concomitante da prevalência da estenose aórtica degenerativa e da doença aterosclerótica arterial coronária. O presente estudo visa avaliar a influência da doença ateroslerótica arterial coronária crítica na mortalidade hospitalar de pacientes portadores de estenose aórtica submetidos à substituição valvar isolada ou combinada à revascularização do miocárdio. No período de janeiro de 2001 a março de 2006, no Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, foram analisados 448 pacientes submetidos à substituição valvar aórtica isolada (grupo GI) e 167 pacientes submetidos à substituição valvar aórtica combinada à revascularização do miocárdio (grupo GII). Os dados pré-operatórios eleitos para análise foram: sexo, idade, índice de massa corpórea, antecedentes de: acidente vascular cerebral, diabete melito, doença pulmonar obstrutiva crônica, febre reumática, hipertensão arterial sistêmica, endocardite, infarto agudo do miocárdio, tabagismo, fração de ejeção do ventrículo esquerdo, doença aterosclerótica arterial coronária crítica, fibrilação atrial crônica; operação valvar aórtica prévia (conservadora), classe funcional de insuficiência cardíaca congestiva, valor sérico de creatinina e de colesterol total, tamanho da prótese utilizada, extensão (completa ou incompleta) e número de anastomoses distais da revascularização do miocárdio, tempo de circulação extracorpórea e tempo de pinçamento aórtico. No estudo estatístico empregou-se análise univariada (teste Qui-Quadrado e teste t de Student) e multivariada (regressão logística) para avaliação da influência da doença aerosclerótica arterial coronária crítica na mortalidade hospitalar dos dois grupos estudados. No grupo GI (substituição valvar aórtica isolada), a mortalidade hospitalar foi 14,3% (64 óbitos), sendo 14,5% (58 óbitos) nos pacientes sem doença aterosclerótica arterial coronária crítica associada (grupo GIB) e 12,8% (6 óbitos) nos que apresentavam essa associação (grupo GIA). No grupo GII (substituição valvar aórtica combinada à revascularização do miocárdio), a mortalidade hospitalar foi 17,6% (29 óbitos), sendo 16,1% (20 óbitos) nos pacientes submetidos à substituição valvar aórtica combinada à revascularização completa do miocárdio (grupo GIIA) e 20,9% (9 óbitos) nos com revascularização incompleta do miocárdio (grupo GIIB). Nos pacientes submetidos à substituição valvar aórtica isolada, a presença de doença aterosclerótica arterial coronária crítica associada, em pelo menos duas artérias, influenciou a mortalidade hospitalar (p= 0,016). Nos pacientes submetidos à substituição valvar aórtica combinada à revascularização do miocárdio, o número de artérias coronárias com doença aterosclerótica crítica e a extensão da revascularização do miocárdio realizada não influenciaram a mortalidade hospitalar (p>0,05), mas a realização de mais de três anastomoses distais influenciou (p= 0,03). / With the increase in life expectancy in recent decades has occurred concomitant increase in the prevalence of degenerative aortic stenosis and atherosclerotic coronary artery disease. This study aim to evaluate the influence of critical atherosclerotic coronary artery disease in hospital mortality of patients with aortic stenosis underwent isolated valve replacement or combined coronary artery bypass grafting. In the period of january 2001 to March 2006, at the Heart Institute University of Sao Paulo Medical Center were examined 448 patients underwent isolated aortic valve replacement (GI group) and 167 patients underwent combined aortic valve replacement and coronary artery bypass grafting (GII group). Preoperative data analised were: sex, age, body mass index, history of stroke, diabetes mellitus, chronic obstructive pulmonary disease, rheumatic fever, hypertension, endocarditis, myocardial infarction, smoking, chronic atrial fibrillation. Left ventricular ejection fraction, concomitant critical atherosclerotic coronary artery disease, previous surgical aortic valvuloplasty, congestive heart failure functional class, serum creatinine and cholesterol level, aortic valve prosthesis size, concomitant complete or incomplete coronary artery bypass grafting and number of bypass grafts, cardiopulmonary bypass and aortic cross clamping time. Univariate statistical analysis (Chi-square and Student\'s t test) and multivariate (logistic regression) were used to evaluate the influence of critical atherosclerotic coronary artery disease in hospital mortality of two groups. GI group (isolated aortic valve replacement) hospital mortality was 14.3% (64 deaths), and 14.5% (58 deaths) in patients without associated critical atherosclerotic coronary artery disease (GIB group) and 12.8% (6 deaths) in patients with that association (GIA group). GII group (combined aortic valve replacement and coronary artery bypass grafting) hospital mortality was 17.6% (29 deaths), and 16.1% (20 deaths) in patients underwent combined aortic valve replacement and complete coronary artery bypass grafting (GIIA group) and 20.9% (9 deaths) in patients with combined incomplete coronary artery bypass grafting (GIIB group). In patients underwent isolated aortic valve replacement, associated critical atherosclerotic coronary artery disease, of at least two arteries, influenced hospital mortality (p = 0016). In patients underwent combined aortic valve replacement and coronary artery bypass grafting, the number of coronary arteries with critical atherosclerotic disease and coronary artery bypass grafting extension didnt influenced hospital mortality (p> 0.05), but more than three coronary distal anastomoses influenced the hospital mortality (p = 0.03).
147

Comparação da função diastólica entre o pré e pós-operatório de pacientes portadores de estenose aórtica ou insuficiência aórtica, baseados em dados bioquímicos e ecocardiográficos / Comparing after and before aortic valve replacement diastolic function in patients with aortic stenosis(AS) or aortic regurgitation(AR)

Berta Paula Napchan Boer 09 February 2010 (has links)
INTRODUÇÃO: Avaliação da função diastólica de pacientes portadores de estenose ou insuficiência aórtica submetidos à troca valvar. OBJETIVOS: Avaliação da função diastólica através da análise do NTpró-BNP como método não invasivo para caracterização da insuficiência cardíaca diastólica, comparando com os dados ecocardiográficos através do Doppler Pulsado em Fluxo Mitral, Doppler Pulsado em Veias Pulmonares e Doppler Tecidual em portadores de IAO e EAO. MÉTODOS: Foram avaliados 63 pacientes, 32 pacientes com IAO (25 pacientes do sexo masculino e 7 do sexo feminino), 31 pacientes com EAO (11 pacientes do sexo masculino e 20 pacientes do sexo feminino). As variáveis foram comparadas na média entre os pacientes portador de IAO e EAO no pré e pós-operatório. RESULTADOS: A idade dos pacientes variou de 21 a 81 com média de 55 anos. Observa-se diferença quanto à média de idades entre as diferentes patologias (t-Student p< 0,0001). Os pacientes com IAO apresentam uma média de idade igual a 45,7±14,3 com variação entre 21 e 79 anos e os pacientes com EAO apresentam uma média de idade igual a 61,5±14,7 com variação entre 21 e 81 anos. Na IAO em relação à disfunção diastólica tivemos os seguintes dados com significância estatística do pré para o pós-operatório (6 meses): TRIV (p=0,0011), diferença entre Tempo de onda A mitral e onda A pulmonar (p=0,0097), Vol. Sistólico de AE (p=0,0019), Vol Sistólico de AE Indexado (0,0011), Vol. Diastólico de AE (p=0,0110), DDVE (p<0,0001), DSVE (p<0,0001), VSF (p<0,0001), VDF (p<0,0001), Massa Indexada de VE (p<0,0001) e Relação Volume/Massa do VE (p<0,0001). Na EAO em relação à disfunção diastólica tivemos os seguintes dados com significância estatística do pré para o pós-operatório (6 meses): E/E (p=0,0379), TRIV (p=0,0072), diferença entre o tempo de onda A mitral e tempo de onda A pulmonar (p=0,0176), Vol sistólico de AE(p=0,0242), Vol. Sistólico de AE indexado (p=0,0237), FEdeAE (p=0,0339), DDVE (p=0,0002), DSVE (p=0,0085), VDF (p=0,0194), Massa Indexada de VE (p<0,0001) e Relação Volume/Massa de VE(p<0,0001). O NTpró-BNP se correlacionou positivamente com os diversos graus de disfunção diastólica tanto no pré como pós-operatório CONCLUSÃO: Foram verificados no estudo da função diastólica variação com significância estatística tanto na IAO como na EAO na comparação do pré e o pós-operatório. Da mesma forma notamos variação do NT-proBNP com correlação com as variáveis ecocardiográficas que caracterizam a disfunção diastólica. / INTRODUCTION: Assessment of diastolic function in patients with aortic stenosis or aortic regurgitation waiting for aortic valve replacement. OBJECTIVE: Assesment of diastolic function with Doppler methods:Doppler signals from transvalvar mitral inflow, tissue Doppler imaging (TDI) and Doppler in pulmonary veins(DPV) correlating with serum brain peptide natriuretic (NTproNP) before and 6 months after aortic valve replacement (AVR). METHODS: We have analyzed 63 patients, 32 with AR (25 males and 7 females), 31 AS (11 males and 20 females).The indices were compared with AS and AR before and after AVR. RESULTS: The ages of patients ranged from 21 to 81 mean age was 55 years old.We have seen difference between mean age of AS and AR (t-Student-p<0.0001). Patients with AR have had mean age 45.67 plus/minus 14.28, range 21 to 79 years old and patients with AS have had mean age 61.50 plus/minus 14.72, range 21 to 81 years old. The patients who had AR the indices showed differences: Isovolumetric Relaxation Time IRT(p=0.0011), Diference between the pulmonary A wave duration and mitral A duration (p=0.0097), Left Atrial Systolic Volume (p=0.0019), Left Atrial Systolic Volume Index(p=0.0011), Left Atrial Diastolic Volume (p=0.0110), Left Ventricular Diastolic Diameter (p<0.0001), Left Ventricular Systolic Diameter (p<0.0001), End Systolic Volume (p<0.0001), End Diastolic Volume (p<0.0001), Left Ventricular Mass Index (p<0.0001) and Left Ventricular Volume and Left Ventricular Mass Index ratio (p<0.0001). Analyzing patients with AS the indices who showed differences: (The ratio of mitral velocity to early diastolic velocity of the mitral annulus) E/E (p=0.0379)(Isovolumetric Relaxation Time)(p=0.0072) IRT, Diference between the pulmonary A wave duration and mitral A duration (p=0.0176), Left Atrial Sistolic Volume (p=0.0242), Left Atrial Systolic Volume Index (p=0.0237), Left Atrial Ejection Fraction (p=0.0339) Left Ventricular Diastolic Diameter (p=0.0002), Left Ventricular Systolic Diameter (p=0.0085), End Diastolic Volume (LVEDV) (p=0.0194), Left ventricular Mass Index(p<0.0001), Left Ventricular Volume and Mass Index Ratio (p<0.0001). CONCLUSIONS: As we studied diastolic function we have verified significant statistic variation in aortic regurgitation and aortic stenosis comparing before and after aortic valve replacement. Likewise we have seen there is correlation between NTproBNP and echocardiographic variables that show diastolic dysfunction.
148

[en] MEASUREMENTS ON THE FLOW OF A HIGHLY SHEAR-THINNING LIQUID PAST AN AXISSYMMETRIC CONTRACTION-EXPANSION: APPLICATION TO BLOOD FLOW THROUGH STENOTIC VESSELS / [pt] MEDIÇÕES DO ESCOAMENTO DE UM LÍQUIDO VISCOPLÁSTICO ATRAVÉS DE UMA CONTRAÇÃO-EXPANSÃO AXISSIMÉTRICA: APLICAÇÕES AO ESCOAMENTO DO SANGUE EM ARTÉRIAS COM ESTENOSE

ERICK FABRIZIO QUINTELLA ANDRADE COELHO 03 December 2001 (has links)
[pt] Estenose é uma constrição ou estreitamento de um duto ou de uma passagem. Este termo é usado freqüentemente em referência a constrições que ocorrem em vasos sangüíneos, especialmente em artérias. Um vaso estenótico geralmente causa estagnação do fluxo sangüíneo e portanto a formação de trombos, os quais podem ser bastante pre- judiciais à saúde humana. Neste trabalho realizam-se experimentos com a técnica de velocimetria por imagens de partículas (PIV) a fim de estudar o escoamento de um líquido que possui uma tensão limite de escoamento (ou líquido viscoplástico) através de um tubo na vizinhança de uma constrição axissimétrica. Escolheu-se a reologia do líquido de modo a se aproximar daquela do sangue de hematócrito igual a 54%. Estudaram-se números de Reynolds e números de escoamento característicos para diferentes artérias. Obtiveram-se também resultados para fluidos Newtonianos, para fins de comparação. Entre outros resultados, observou- se que a reologia não Newtoniana causa mudanças significativas no padrão de escoamento na vizinhança da estenose. Como as condições para formação de trombos estão diretamente relacionadas com o padrão de escoamento, estudos do escoamento do sangue através de artérias com estenose que supõem uma reologia Newtoniana podem levar a conclusões errôneas. / [en] Stenosis is a constriction or narrowing of a duct or passage. This word is often used to refer to constrictions that occur in blood vessels, especially arteries. A stenotic vessel generally causes blood flow stagnation and hence formation of thrombus, which may be rather harmful to the human physiology. In this work we perform particle image velocimetry (PIV) experiments to study the flow of an yield-stress (or highly shear-thinning) liquid through a tube in the neighborhood of an axisymmetric constriction. The rheology of the liquid was chosen to be close to the one of blood with 54% hematocrit. Reynolds and Yield number values characteristic to different arteries have been studied. Results for a Newtonian liquid were also obtained, for comparison purposes. Among other findings, it has been observed that the non-Newtonian rheology causes a significant change in the flow pattern in the neighborhood of the stenosis. Because the conditions for thrombus formation are directly related to the flow pattern, studies of the flow through stenotic vessels that assume a Newtonian rheology may lead to erroneous conclusions.
149

Alterações de difusão e perfusão cerebral por RM em angioplastia carotídea com \"stent\" sob proteção cerebral por filtros / Changes in diffusion and perfusion weighted magnetic resonance imaging in carotid angioplasty with stenting under cerebral protection by filters

Sá Júnior, Antenor Tavares de 09 October 2009 (has links)
INTRODUÇÃO: A angioplastia carotídea com stent (ACS) sob proteção cerebral é opção terapêutica em pacientes com estenose carotídea. Existe o risco de embolia apesar da utilização do filtro e as modificações na perfusão cerebral após tratamento da estenose carotídea não são claras. O propósito deste estudo é avaliar, após ACS sob proteção cerebral por filtros, modificações nas seqüências de RM de difusão (DWI) e perfusão (PWI), correlacionando-as com os aspectos técnicos da ACS, com as características da estenose e com dados demográficos dos pacientes. MÉTODO: Trinta e seis pacientes portadores de estenose carotídea com idade média de 72,08 anos foram submetidos a exame de RM um dia antes e até 72 horas após a ACS com filtro de proteção. Todos os pacientes eram assintomáticos após a ACS. Áreas de restrição na DWI após a ACS foram correlacionadas com aspectos demográficos, com aspectos da técnica de angioplastia e com a presença de infartos prévios por RM. Os parâmetros CBV volume sanguíneo cerebral, MTT tempo de trânsito médio e TTP tempo para o pico são empregados para análise por PWI. RESULTADOS: Na DWI, 18 de 36 (50,00%) pacientes apresentaram novos focos (NF) de restrição na DWI após ACS. Todos os NF foram clinicamente silenciosos (100%). Estes NF eram localizados em território cerebral nutrido pela artéria carótida submetida à ACS em 77,19% e menores que 10 mm em 91,53%. Os NF em território cerebral não irrigado pela artéria carótida submetida à angioplastia correspondiam a 22,81% destes. A presença de infartos cerebrais prévios na RM foi o único fator com influência no aparecimento de NF (p=0,037). Fatores demográficos e aspectos relacionados com a técnica de angioplastia não tiveram importância na gênese dos NF. Na PWI foi observada melhora nos parâmetros temporais TTP (p<0,001) e MTT (p=0,019) quando comparados de forma normalizada em relação ao território contralateral. CONCLUSÃO: Os novos focos de restrição na DWI após ACS (NF) foram mais comuns no território ipsilateral (77,19%), no entanto houve NF no território contralateral à ACS (22,81%), possivelmente, associados ao cateterismo diagnóstico. Os NF, na sua maioria, são de pequeno diâmetro (<10 mm em 91,53%). Melhora precoce na PWI, observada nos dados normalizados, foi demonstrada nos parâmetros temporais (TTP e MTT). / INTRODUCTION: Carotid angioplasty with stent (CAS) under cerebral protection is a therapeutic option in patients with carotid stenosis. There is a risk of embolism even with a filter, and changes in cerebral perfusion after treatment are not clearly understood. The purpose of this study was to evaluate changes in diffusion- (DWI) and perfusion- (PWI) weighted magnetic resonance imaging (MRI) sequences correlating them with the technical aspects of CAS, stenosis characteristics and patient demographic data. METHODS: Thirty-six carotid stenosis patients with an mean age of 72.08 years were submitted to MRI exam one day before and up to 72 hours after CAS with filter protection. All patients were asymptomatic after CAS. Areas of restriction on DWI were correlated to demographic aspects, technique of angioplasty as well the presence of previous stroke by MRI. The parameters, CBV - cerebral blood volume; MTT - mean transit time, and TTP- time to peak, are used for PWI analysis. RESULTS: Eighteen of the 36 patients (50.00%) presented new focus (NF) of restriction by DWI after CAS. All new focus were clinically silent. The NF were located in the cerebral area fed by the carotid artery submitted to CAS in 77.19% and smaller than 10mm in 91.53%. NF in cerebral area not irrigated by carotid artery submitted by angioplasty correspond to 22,81 %. The presence of previous ischemic lesion on MRI was the only factor which influenced the appearance of NF (p=0.037). Demographic factors and aspects related to angioplasty technique had no importance on NF genesis. Improvement in PWI timing parameters - TTP (p<0.001) and MTT (p=0.019) were observed in relation to the contralateral territory (normalized data). CONCLUSION: The restriction NF in the DWI after CAS are more common in the ipsilateral territory (77.19%), however there were some NF in the contralateral territory to the CAS (22.81%), possibly associated with diagnostic catheterization. Most of the NF were small in diameter (<10mm in 91.53%). Short-term improvement in PWI were demonstrated by normalized timing parameters (TTP and MTT).
150

Avaliação da associação da gordura pericárdica medida pela tomografia computadorizada com a presença de aterosclerose coronária subclínica em pacientes com hipercolesterolemia familiar / Study of the association of pericardial fat determined by computed tomography with the presence of subclinical coronary atherosclerosis in patients with familial hypercholesterolemia

Mangili, Leonardo Celeste 27 September 2016 (has links)
A hipercolesterolemia familiar (HF) é uma doença causada por um grupo de alterações genéticas que resultam em altas concentrações de colesterol no sangue e aumento na prevalência de aterosclerose subclínica e risco de eventos coronarianos precoces. Apesar da importância do colesterol como fator causal da aterosclerose na HF, o curso desta última é variável e influenciado por outros fatores de risco. A gordura pericárdica é um compartimento da gordura visceral e está associada à presença de aterosclerose coronária subclínica em populações sem HF. Este estudo avaliou a associação da gordura pericárdica com a presença e extensão da aterosclerose coronária subclínica em pacientes com HF. Noventa e sete pacientes com HF diagnosticada por critérios clínicos, confirmada geneticamente em 67% dos casos, foram submetidos a angiotomografia de coronárias e determinação do escore de cálcio (CAC). Foram analisadas a presença de placas, de estenose luminal > 50%, de CAC > 0 e do percentil de CAC > 75. Para se quantificar a extensão e gravidade da aterosclerose coronária subclínica foram avaliados de forma contínua a CAC, o Segment-Involvement Score (SIS) e o Segment-Stenosis Score (SSS). O volume de gordura pericárdica foi aferido por método semiautomático e dividido em dois compartimentos: gordura epicárdica (localizada dentre do saco pericárdico) e mediastinal (localizada fora do pericárdio). Para avaliar a associação dos volumes de gordura pericárdica com a aterosclerose subclínica foram ajustados modelos de regressão logística e linear. Os pacientes tinham idade média de 45 (±13) anos, com predomínio do sexo feminino. Foi encontrada presença de placas coronarianas e de CAC em 47,4% e 45,4% dos pacientes, respectivamente. Idade, colesterol total, LDL-C, HDL-C, apolipoproteína A-I, apolipoproteína B, presença de xantomas de tendão de Aquiles e clearance de creatinina foram associados a aterosclerose coronária subclínica na análise univariada. Os volumes de gordura pericárdica se associaram à presença de síndrome metabólica, hipertensão arterial, idade, IMC, a circunferência abdominal, o colesterol não-HDL, triglicerídeos e glicemia de jejum. Na análise multivariada em modelos ajustados para idade, sexo, tabagismo, HDL-C, LDL-C, circunferência abdominal, síndrome metabólica e uso prévio de estatinas, a gordura epicárdica foi associada independentemente com o percentil de CAC > 75 e foi diretamente proporcional a intensidade da CAC, SSS e SIS. Em conclusão, a gordura epicárdica associou-se independentemente à maior extensão e gravidade de aterosclerose coronária subclínica em pacientes com HF / Familial hypercholesterolemia (FH) is a disease caused by a group of genetic mutations resulting in high blood cholesterol and elevated prevalence of subclinical atherosclerosis and early coronary events. Although high cholesterol is the driving cause of atherosclerosis in FH, the course of the latter is variable and is affected by other risk factors. Pericardial fat (PF) is a visceral fat compartment that is associated to the presence of subclinical atherosclerosis in non-FH populations. The present study sought to determine the association of PF with the presence and extent of subclinical coronary atherosclerosis in FH subjects. Ninety-seven patients with clinical diagnosis of FH, genetically confirmed in 67%, were submitted to coronary tomography angiography and coronary artery calcium (CAC) quantification. The presence of plaques, luminal stenosis > 50%, CAC > 0, CAC percentile above 75 were evaluated. In order to evaluate the extent and severity of subclinical atherosclerosis, the CAC scores, Segment-Involvement Score (SIS) and Segment-Stenosis Score (SSS) were also measured. Pericardial fat volumes were measured by semi automated method and divided in two compartments: epicardial fat (located inside the pericardial sac) and mediastinal fat (located outside pericardial sac). Logistic regression and linear models tested the association of PF volumes with subclinical coronary atherosclerosis. Patients were predominantly female, with mean age of 45 (± 13) years. Coronary plaques and CAC were found respectively in 47.4% and 45.4% of patients. Age, total cholesterol, LDL-C, HDL-C, apolipoproteins A-I and B, the presence of Achilles xanthomas and creatinine clearance were associated with subclinical coronary atherosclerosis in univariate analysis. PF volumes were associated with the presence of metabolic syndrome, hypertension age, BMI, abdominal circumference non-HDL-cholesterol triglycerides and fasting glucose. On multivariate analysis in models adjusted for age, sex, smoking, HDL-C, LDL-C, abdominal circumference, metabolic syndrome and previous statin use epicardial fat was independently associated with CAC > 75th percentile, and was directly proportional to the intensity of CAC, SSS and SIS. In conclusion, epicardial fat was independently associated with a greater extension and severity of subclinical atherosclerosis in FH patients

Page generated in 0.0642 seconds