• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 279
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 295
  • 295
  • 202
  • 134
  • 109
  • 88
  • 83
  • 74
  • 69
  • 68
  • 66
  • 64
  • 62
  • 61
  • 58
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Software embarcado de controle para triciclo assistido por estimulação elétrica / Embedded control software for a tricycle assisted by electrical stimulation

Brindeiro, George Andrew 20 March 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2017. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2017-08-03T16:20:41Z No. of bitstreams: 1 2017_GeorgeAndrewBrindeiro.pdf: 7244557 bytes, checksum: 8721ced187422d4cb825fa339c97c834 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-09-06T22:53:07Z (GMT) No. of bitstreams: 1 2017_GeorgeAndrewBrindeiro.pdf: 7244557 bytes, checksum: 8721ced187422d4cb825fa339c97c834 (MD5) / Made available in DSpace on 2017-09-06T22:53:07Z (GMT). No. of bitstreams: 1 2017_GeorgeAndrewBrindeiro.pdf: 7244557 bytes, checksum: 8721ced187422d4cb825fa339c97c834 (MD5) Previous issue date: 2017-09-06 / Este trabalho visa estudar e aplicar diferentes técnicas e práticas no desenvolvimento de software embarcado de controle de um triciclo adaptado para a prática do ciclismo auxiliado por estimulação elétrica funcional. Entre normas técnicas relacionadas a dispositivos médicos e boas práticas de engenharia de software, buscou-se entender que estratégias poderiam ser adotadas para mitigar anomalias e avaliar a qualidade de software nesse contexto. Levando em consideração os riscos presentes no dispositivo, foi proposta uma nova arquitetura de software para mitigá-los, utilizando o framework Robot Operating System (ROS). A arquitetura proposta e sua implementação foram avaliadas com base em quatro atributos internos de qualidade de software: modifiabilidade, reusabilidade, verifiabilidade e proteção. / This work aims to study and apply different development techniques and practices to the embedded control software to a tricycle adapted for functional electrical stimulation cycling. Between technical standards related to medical devices and software engineering best practices, it attempts to understand which strategies could be adopted to mitigate anomalies and evaluate the quality of software in this context. Considering the risks presented by the device, a new software architecture was proposed to mitigate them, using the Robot Operating System (ROS) framework. The proposed architecture and its implementation were evaluated based on four internal software quality attributes: modifiability, reusability, verifiability and safety.
32

Modificações no controle inibitório de indivíduos com transtorno do déficit de atenção e hiperatividade submetidos a ETCC : ensaio clínico, randomizado, duplo-cego, cross over

Simione, Renata Moraes 01 December 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-12-22T16:04:47Z No. of bitstreams: 1 2017_RenataMoraesSimione.pdf: 769375 bytes, checksum: 54a9bc55398806f9bf8e227bf082316b (MD5) / Approved for entry into archive by Patrícia Nunes da Silva (patricia@bce.unb.br) on 2018-01-16T17:06:01Z (GMT) No. of bitstreams: 1 2017_RenataMoraesSimione.pdf: 769375 bytes, checksum: 54a9bc55398806f9bf8e227bf082316b (MD5) / Made available in DSpace on 2018-01-16T17:06:01Z (GMT). No. of bitstreams: 1 2017_RenataMoraesSimione.pdf: 769375 bytes, checksum: 54a9bc55398806f9bf8e227bf082316b (MD5) Previous issue date: 2018-01-16 / A Estimulação Elétrica Transcraniana por Corrente Contínua (ETCC) demonstrou ser uma ferramenta promissora para melhorar o desempenho cognitivo em muitas condições neuropsiquiátricas. O objetivo do nosso trabalho foi descrever as modificações no controle inibitório de indivíduos com Transtorno de Déficit de Atenção/Hiperatividade (TDAH) após o ETCC. Métodos: 10 indivíduos foram submetidos a avaliação neuropsicológica e foram classificados de acordo com o DSM-V (Diagnóstico e Manual Estatístico de Distúrbios Mentais). Sua capacidade cognitiva também foi avaliada através da realização de todos os testes incluídos na Escala de Inteligência de Adultos Wechsler 3ª Edicação (WAIS, III). Após a avaliação cognitiva, 10 indivíduos foram divididos aleatoriamente, por sorteio, em 2 grupos: grupo experimental (n = 5) e grupo controle (n = 5). As sessões de tratamento de ETCC e estimulação simulada foram aplicadas a cada grupo de acordo com a fase de estudo. O teste STROOP foi realizado antes, durante e após ETCC e estimulação simulada para avaliar o controle inibitório na população estudada. Resultados: observou-se melhora no controle inibitório no grupo experimental durante as sessões de ETCC. Não houve diferença estatisticamente significativa durante as sessões do grupo placebo. Conclusão: nosso estudo demonstrou que o controle inibitório, em indivíduos com TDAH, pode ser melhorado aplicando a ETCC como ferramenta terapêutica. / Transcranial Direct-Current Stimulation (tDCS) has been proven to be a promising tool to improve cognitive performance in many neuropsychiatric conditions. The aim of our work was to describe modifications in the inhibitory control of individuals with Attention Deficit/Hyperactivity Disorder (ADHD) after tDCS. Methods: 10 individuals underwent neuropsychological evaluation and were classified according to DSM-V (Diagnostic and Statistical Manual of Mental Disorders). Their cognitive ability was also assessed by performing all tests included in Wechsler Adult Intelligence Scale (WAIS, III). After cognitive evaluation, 10 subjects were randomly divided by lot into 2 groups: experimental group (n=5) and Control group (n=5). Treatment sessions of tDCS or sham stimulation were applied to each group according to the phase of study. STROOP test was performed before, during and after tDSC or sham-stimulation sessions to evaluate inhibitory control in the studied population. Results: An improvement in inhibitory control was observed in the experimental group during the TDCS. No significant differences were observed during sham sessions. Conclusion: Our study demonstrated that inhibitory control, in individuals with ADHD, can be improved by applying tDCS as a therapeutic tool.
33

Responsividade aos parâmetros de eletroestimulação dos músculos paralisados para o ciclismo na paraplegia / Study of responsiveness to electrical stimulation of paralyzed muscles in paraplegia

Guimarães, Juliana Araújo 06 December 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação em Ciências e Tecnologias em Saúde, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-03-27T21:57:22Z No. of bitstreams: 1 2017_JulianaAraújoGuimarães.pdf: 4713798 bytes, checksum: 735fa8d79073975408c71b3cad609347 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-04-03T14:46:06Z (GMT) No. of bitstreams: 1 2017_JulianaAraújoGuimarães.pdf: 4713798 bytes, checksum: 735fa8d79073975408c71b3cad609347 (MD5) / Made available in DSpace on 2018-04-03T14:46:06Z (GMT). No. of bitstreams: 1 2017_JulianaAraújoGuimarães.pdf: 4713798 bytes, checksum: 735fa8d79073975408c71b3cad609347 (MD5) Previous issue date: 2018-03-03 / Fundação de Apoio à Pesquisa do Distrito Federal (FAP-DF); Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES); Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); Associação de Centro de Treinamento de Educação Física Especial (CETEFE). / Introdução: É imperativo o desenvolvimento de tecnologias assistivas que possibilitem a pessoas com lesão medular a realização de exercícios físicos em intensidade suficiente para prevenir complicações relacionadas a inatividade física e proporcionar modificações positivas no estado de saúde. Objetivos: Nesse sentido, este estudo observacional investigou a responsividade e características dessa responsividade à eletroestimulação por parâmetros pré-estabelecidos (comumente aplicados na prática da FES), reconhecendo assim alguns requisitos para a prática de ciclismo assistido por eletroestimulação. Métodos: Quatorze pessoas com lesão medular foram avaliadas quanto as possíveis variáveis preditoras de responsividade a eletroestimulação: fatores pessoais, aspectos relacionados à condição de saúde, características estruturais e funcionais, variáveis de estabilidade hemodinâmica, assim como atividade e participação. Resultados e Discussão: Observamos uma variedade de respostas (entre contração equivalente a grau 1/5 e grau 4/5 na escala MRC) relacionada aos diferentes níveis e completudes da lesão medular encontradas nessa amostra. O nível de lesão acima de T12 e a etiologia traumática seriam fatores preditores do sucesso da responsividade por parâmetros pré-definidos para a estimulação elétrica funcional. Ao acompanhar a responsividade à eletroestimulação em sessões repetidas para os participantes que não foram responsivos na sessão inicial, levantamos como características que poderiam favorecer tal responsividade: a preservação parcial das raízes periféricas abaixo do nível de lesão e a preservação de um nível de trofismo muscular que possibilite ainda a reorganização do aparato de excitação-contração. Conclusão: é possível que os pacientes classificados como não responsivos sejam falsos negativos em função do emprego de parâmetros inadequados. Recomendamos que estudos eletrodiagnósticos sejam utilizados para a eleição individual dos melhores parâmetros de eletroestimulação. / Muscular paralysis, autonomic alterations, and secondary complications from immobility make physical activity and sport a challenge for people with spinal cord injury. The few existing options are activities that require the upper limbs, often overwhelmed in everyday activities such as locomotion and transfers. Often the practice of the activity requires the use of equipment and specialized professional that, when available, usually have a high financial cost. In this context, people with spinal cord injury continues to be the most inactive part of society and, as a consequence, it presents lower life expectancy and high rates of early mortality due to cardiovascular and respiratory complications, as well as high rates of hospitalization. For these reasons, it is imperative to develop assistive technologies that enable people with spinal cord injury to perform physical exercises at sufficient intensity to prevent complications related to physical inactivity. And, in addition, provide positive changes in health status, based on the reflections on fundamental concepts to identify the well-being of a human being, based on the most current models of health care and classification of health-related information. This study has an observational methodological basis designed to meet each of the specific objectives set to achieve the general objective of this proposal, which was to investigate the responsiveness and characteristics of this responsiveness to the electrical stimulation by pre-established parameters (commonly applied in FES practice), recognizing thus some requirements for the practice of cycling assisted by electrostimulation. Fourteen people participated in the protocol in a sample predominantly formed by young adult women with spinal cord injury, living for more than two years with the condition of paraplegia. The patients were evaluated as the variables selected by us as possible predictors of electrostimulation responsiveness that were organized by: personal factors (age and gender); by aspects related to the health condition (chronicity, cause of injury, level and completeness of the injury); by structural and functional characteristics identified by the American Spinal Injury Association, known as ASIA Impairment Scale (AIS), as well as Body Mass Index (BMI), lower limb perimeters, thoracic cirtometry, of hemodynamic stability (blood pressure and XV heart rate), as well as the activity and participation quantified by the amount of sports practiced and Functional Independence Measure. During the application of the protocol, we observed a variety of responses (between contractions sketches equivalents to grade 1/5 to stronger contractions, equivalent to grade 4/5 on the MRC scale) related to the different levels and complements of the spinal cord injury found in this sample. We found suggestive results that the level of injury above T12 and the traumatic etiology of the lesion would be factors that could predict the success of electrostimulation responsiveness by predefined parameters for functional electrical stimulation. When monitoring the responsiveness to electrostimulation in repeated sessions for participants who were not responsive to electrostimulation in the initial session, we pointed as characteristics that could favor such responsiveness: partial preservation of the peripheral roots below the level of injury and the preservation of a level of trophism muscle that allows the reorganization of the excitation-contraction apparatus.
34

Avaliação da incontinência urinária 8 anos após a realização de estimulação elétrica transvaginal

Trindade, Camila Martins Chaves January 2010 (has links)
Resumo não disponível
35

Utilização da estimulação elétrica neuromuscular (EENM) em crianças com paralisia cerebral do tipo diplegia espástica

Staub, Ana Lucia Portella January 2005 (has links)
Resumo não disponível
36

Estimulação elétrica neuromuscular para o fortalecimento muscular, função e dor em pacientes com osteoartrite do joelho : uma revisão sistemática com meta-análise

Bispo, Vinícius Araújo 23 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação em Ciências da Reabilitação, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-09-10T22:41:38Z No. of bitstreams: 1 2018_ViníciusAraújoBispo.pdf: 597175 bytes, checksum: b9d67e5d7e3141712989590fb535dd4e (MD5) / Approved for entry into archive by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-09-11T20:32:28Z (GMT) No. of bitstreams: 1 2018_ViníciusAraújoBispo.pdf: 597175 bytes, checksum: b9d67e5d7e3141712989590fb535dd4e (MD5) / Made available in DSpace on 2018-09-11T20:32:28Z (GMT). No. of bitstreams: 1 2018_ViníciusAraújoBispo.pdf: 597175 bytes, checksum: b9d67e5d7e3141712989590fb535dd4e (MD5) Previous issue date: 2018-09-10 / Desenho do estudo: Trata-se de um estudo do tipo revisão sistemática com meta-análise Introdução. A estimulação elétrica neuromuscular (EENM) é amplamente utilizada como estratégia para melhorar o desempenho muscular. No entanto, os parâmetros físicos utilizados e a sua efetividade para promover um aumento na força muscular, redução da dor ou melhora na função física em pacientes com osteoartrite (OA) do joelho ainda não são completamente estabelecidos. Objetivo: Investigar os efeitos da EENM na produção de força muscular, redução da dor e melhora da função física em pacientes com osteoartrite do joelho. Métodos: A partir das palavras-chaves pré-estabelecidas, foram pesquisados apenas ensaios clínicos randomizados (ECRs) nas bases de dados: Pubmed, Embase, LILACS, PEDro e no Registro Central de Ensaios Controlados da Cochrane Central (CENTRAL). Dois revisores independentes selecionaram os estudos de acordo com os critérios de inclusão, extraíram os dados e avaliaram a qualidade metodológica. Extração dos dados e síntese: Os estudos foram elegíveis para esta revisão se comparassem a intervenção realizada por meio da EENM de forma isolada ou combinada com o exercício versus um grupo que realizou exercício convencional ou um grupo controle (Sem nenhuma intervenção). Aqueles estudos que incluíram medidas de resultados para valores relacionados ao torque isométrico máximo, torque evocado (% Contração Isométrica Voluntária Máxima - CIVM), nível de desconforto alto relatado, escala de dor e nível da função física foram elegíveis para avaliação. Apenas onze estudos foram incluídos nesta revisão. Após realizar as análises estatísticas para os desfechos da força muscular isométrica, função física e dor, foi identificado uma diferença estatística significativa favorável apenas para um aumento da força muscular isométrica. Este resultado benéfico se restringe apenas para a comparação da utilização da EENM versus o grupo controle. A qualidade metodológica dos ensaios elegíveis foi moderada, com uma média de cinco pontos na escala PEDro. Limitações: Algumas limitações surgem da estratégia de pesquisa para identificar estudos clínicos. Seguindo as recomendações da Cochrane Colaborações, as pesquisas foram complementadas pela identificação de possíveis estudos elegíveis na busca manual, bem como os registros de ensaios clínicos. Conclusão: Sugere-se que a EENM comparada ao grupo controle oferece benefícios para promover um aumento na força muscular isométrica do músculo quadríceps femoral em pacientes com osteoartrite do joelho. Porém, a EENM não promove uma redução da dor ou melhora na função física nesta população quando comparado ao controle e ao exercício. / Study design: This is a systematic review with meta-analysis. Introduction: The Neuromuscular Electrical Stimulation (NMES) is widely used as a strategy to improve a muscle performance. However, the physical parameters used and their effectiveness to promote an increase in muscle strength, pain reduction or improvement in physical function in patients with osteoarthritis (AO) of the knee are not yet established completely. Objective: To investigate the effects of NMES on the production of muscle strength, pain reduction and improvement of the physical function of patients with osteoarthritis of the knee. Methods: From pre-established keywords, were investigated only randomized clinical trials (ECRs) in databases: Pubmed, Embase, LILACS, PEDro and in a Cochrane Central Register of Controlled Trials. Two independent reviewers selected the studies according the inclusion criteria, they extracted the data and evaluated the methodological quality. Data extraction and synthesis: The studies were eligible for this review if they compared the intervention performed through the Neuromuscular Electrical Stimulation in isolation or combined with exercise versus a group that performed conventional exercise or a control group. Those studies that include measures of results for values related to maximum isometric torque, evoked torque (% Maximum Voluntary Isometric Contraction - MVIC), level of self-reported discomfort, pain scale and level of physical function were eligible for evaluation. After performing the statistical analyzes for the isometric muscle strength, function and pain outcomes, a statistically significant difference was found favorable only for an increase in isometric muscle strength. This beneficial result is restricted only to the comparison of NMES use versus the control group. The methodological quality of the eligible trials was moderate, with an average of 5 points on the PEDro scale. Limitations: Some limitations emerge from a research strategy to identify clinical studies. Following the recommendations of Cochrane Collaborations, the research was complemented by identifying possible eligible studies in the manual search as well as clinical trial records. Conclusion: It is suggested that the NMES when compared with the control group offers benefits to promote an increase in isometric muscle strength of quadriceps femoris muscle in patients with osteoarthritis of the knee. However, the NMES does not promote a reduction in pain or improvement of physical function in this population compared to control and exercise.
37

Efeitos da mobilização motora precoce em pacientes em ventilação mecânica

Torquato, Joana Maccarini 15 March 2013 (has links)
Dissertação de Mestrado apresentada ao Programa de Pós-Graduação em Ciências da Saúde da Universidade do Extremo Sul Catarinense para obtenção do título de Mestre em Ciências da Saúde. / The mechanical ventilation (MV) is an essential ventilatory support in patients with acute respiratory insufficiency in intensive care units (ICU), but long periods of exposure to MV can promote several changes in the clinical and redox state. This study aimed to evaluate the effects of different physical therapy protocols (electrical stimulation and passive exercise) and the relation these protocols on clinical indicators and oxidative damage parameters in patients exposed to MV. 86 patients, age > 18 yrs, both sex under MV for more than 2 days and to stayed in the ICU for at least 5 days were divided into 4 groups: control (n=24), passive exercise (n=19), electrical stimulation (n=21) and passive exercise plus electrical stimulation (n=22). The clinical data were collected daily and noted in the patient´s medical record and blood samples (3-mL) were collected from each patient twice, at the beginning of the implementation of protocols (baseline) and at the end of treatment for oxidative damage analysis. In relation the characteristics of patients, no major significant differences were observed between groups although death during protocol presented a borderline association (F = 7.296, p = 0.048). Clinical data, no was observed significant difference between groups either on baseline or on their the Last Observation Carried Forward (LOCF). While we have not observed significant differences on thiol content variation from baseline (H = 2.904, p = 0.406), xylenol variation was significant between groups (H = 19.521, p = 0.0002). Post hoc analysis indicated significant differences between protocol 1 and 4 (q = 3.912) as well as 1 and 3 (q = 3.430). Observed variation on xylenol content is not explained by protocol length (p = 0.943). It was not possible to provide conclusive results about the effects of the protocols used. However, there is evidence that the therapeutic routines that contribute for reduce oxidative damage. However it is suggested future studies with greater control of the variables ensuring better stratification of subjects. / A ventilação mecânica (VM) é um apoio essencial ventilatório em pacientes com insuficiência respiratória aguda em unidades de terapia intensiva (UTI), mas longos períodos de exposição a VM pode promover várias mudanças no quadro clínico e no estado redox. Este estudo teve como objetivo avaliar os efeitos de diferentes protocolos fisioterapêuticos (eletroestimulação e exercício passivo) e a relação destes protocolos com indicadores clínicos e os parâmetros de dano oxidativo em pacientes expostos à VM. Oitenta e seis pacientes, com idade superior a 18 anos, de ambos os gêneros sob VM por mais de 2 dias e que permaneceram na UTI pelo menos por 5 dias foram divididos em 4 grupos: controle (n = 24), exercício passivo (n = 19), eletroestimulação (n = 21) e exercício passivo mais eletroestimulação (n = 22). Os dados clínicos foram coletados diariamente por meio do registo médico do paciente e as amostras de sangue (3-mL) foram coletadas de cada paciente, duas vezes, uma no início da aplicação de protocolos (basal) e no final do tratamento para análise de danos oxidativo. Em relação as características dos pacientes, não existem grandes diferenças significativas observadas entre os grupos, embora a morte durante o protocolo apresentou uma associação limítrofe (F = 7,296, p = 0,048). Os dados clínicos, não apresentaram diferenças significativas entre os grupos, quer nos valores basais ou a ultima observação realizada (LOCF). Embora não tenhamos observado diferenças significativas na variação basais no conteúdo total de tióis (H = 2,904, p = 0,406), uma variação significativa foi observada em xilenol entre os grupos (H = 19,521, p = 0,0002). Análise post hoc indicaram diferenças significativas entre o protocolo 1 e 4 (q = 3,912), bem como 1 e 3 (q = 3,430). A variação no conteúdo xilenol não mostrou correlação com o tempo de exposição a VM (p = 0,943). Não foi possível fornecer resultados conclusivos sobre os efeitos dos protocolos usados. No entanto, há evidências de que as rotinas terapêuticas contribuem para reduzir os danos oxidativos. Sugere-se estudos futuros com maior controle das variáveis que garantem uma melhor estratificação dos indivíduos.
38

Efeitos da eletroestimulação transcutânea do nervo tibial sobre a variabilidade da frequência cardíaca nos índices lineares e não lineares / transcutaneous electrical stimulation of the tibial nerve effects on heart rate variability in the linear and nonlinear indices

Chambrone, Joana Zambrano [UNESP] 29 June 2016 (has links)
Submitted by JOANA ZAMBRANO CHAMBRONE null (jo_chambrone@hotmail.com) on 2016-08-15T21:25:10Z No. of bitstreams: 1 DEFESA - Joana Zambrano Chambrone.pdf: 1196001 bytes, checksum: 59124632b4658567fdd3f09803a86cbe (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-17T13:26:49Z (GMT) No. of bitstreams: 1 chambrone_jz_me_prud.pdf: 1196001 bytes, checksum: 59124632b4658567fdd3f09803a86cbe (MD5) / Made available in DSpace on 2016-08-17T13:26:49Z (GMT). No. of bitstreams: 1 chambrone_jz_me_prud.pdf: 1196001 bytes, checksum: 59124632b4658567fdd3f09803a86cbe (MD5) Previous issue date: 2016-06-29 / Introdução: A incontinência urinária (IU) é um sintoma que vai se caracterizar pela perda involuntária de urina, causando problemas higiênicos, sociais, psicológicos. Existem três tipos de IU e uma delas é a de urgência (IUU). A eletroestimulação transcutânea do nervo tibial (ETNT) pelo aparelho TENS é um dos tratamentos mais eficazes para esse tipo IU. A população mais atingida pela IUU são as mulheres que estão na menopausa e neste período é comum elas sofrerem com patologias cardíacas, por este motivo, torna-se importantíssimo identificar o que podem ser fatores de risco cardiovasculares. Um dos métodos que podemos utilizar para avaliar esse estresse cardíaco é a Variabilidade da Frequência Cardíaca (VFC). Objetivo: Verificar se a aplicação do TENS pode alterar a modulação autonômica da frequência cardíaca e se este tratamento é seguro. Métodos: 15 mulheres na menopausa e com IUU foram submetidas a um protocolo experimental com três etapas: Análise da VFC durante dez minutos de repouso, ETNT por vinte minutos e Análise da VFC durante período de trinta minutos de recuperação. Os parâmetros frequência cardíaca (FC), pressão arterial (PA), frequência respiratória(f) e os índices da VFC, no domínio do tempo (RMSSD, PNN50, SDNN), da frequência (LF e HF(ms2) e LF/HF) e geométrico (SD1), foram observados durante o repouso e na recuperação. Para as comparações dos valores dos índices da VFC entre os momentos (repouso vs. períodos de recuperação) foi utilizado o teste de ANOVA uma via seguida pelo pós-teste de Bonferroni para distribuições paramétricas ou o pós-teste de Newman Keuls para distribuições não paramétricas. A significância estatística foi fixada em 5% para todas as análises. Resultados: Não foram encontradas diferenças entre os momentos entre repouso e recuperação pós ETNT. Conclusão: A ETNT não foi capaz de influenciar a regulação autonômica dessas mulheres. / Urinary incontinence (UI) is a symptom that will be characterized by the involuntary loss of urine, causing sanitary, social, psychological problems. There are three types of UI and one of them is urgent (UUI). Transcutaneous electrical stimulation of the tibial nerve (TETN) the TENS unit is one of the most effective treatments for this type UI. The population most affected by IUU are women who are in menopause and this period is common they suffer with heart problems, for this reason, it is important to identify what can be cardiovascular risk factors. One of the methods we can use to evaluate cardiac stress this is the Heart Rate Variability (HRV). Objective: To determine whether the application of TENS can change the autonomic modulation of heart rate and if this treatment is safe. Methods: 15 postmenopausal women with UUI and were subjected to an experimental protocol with three steps: HRV analysis for ten minutes of rest, TETN for twenty minutes and Analysis of HRV during thirty minutes of recovery. The parameters heart rate (HR), blood pressure (BP), respiratory rate (f) and the indices of HRV in the time domain (RMSSD, PNN50, SDNN), frequency (LF and HF (ms2) and LF / HF ) and geometric (SD1), were observed during rest and recovery. For comparisons of the values ​​of HRV indices between times (vs. rest periods of recovery) was used ANOVA one way followed by Bonferroni post-test for parametric distributions or the Newman Keuls post-test for nonparametric distributions . Statistical significance was set at 5% for all analyzes. Results: No differences were found between the moments of rest and post TETN recovery. Conclusion: TETN was unable to influence the autonomic regulation of these women.
39

Capacidade cardiorrespiratória em cardiopatas : instrumentos diretos e indiretos de avaliação e os efeitos da mioestimulação elétrica

Neves, Laura Maria Tomazi 04 April 2014 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação em Ciências e Tecnologia em Saúde, 2014. / Submitted by Laura Conceição (laurinha.to@gmail.com) on 2014-11-27T18:31:18Z No. of bitstreams: 1 2014_LauraMariaTomaziNeves.pdf: 4189180 bytes, checksum: 176fd857c790e25a65b8d25e92290ed6 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2014-11-27T19:24:28Z (GMT) No. of bitstreams: 1 2014_LauraMariaTomaziNeves.pdf: 4189180 bytes, checksum: 176fd857c790e25a65b8d25e92290ed6 (MD5) / Made available in DSpace on 2014-11-27T19:24:28Z (GMT). No. of bitstreams: 1 2014_LauraMariaTomaziNeves.pdf: 4189180 bytes, checksum: 176fd857c790e25a65b8d25e92290ed6 (MD5) / Introdução: O Estudo 1 teve como objetivo desenvolver uma versão brasileira do Duke Activity Status Index (DASI) e adaptar culturalmente para a avaliação indireta da CCR em pacientes com doença cardiovascular no Brasil. Métodos: O processo de tradução envolveu quatro etapas: tradução inicial, retrotradução, revisão multidisciplinar por um comitê e préteste com 16 indivíduos (8 cardiopatas e 8 indivíduos saudáveis). Os testes qui-quadrado e Mann -Whitney foram empregados para determinar as diferenças entre os controles e os indivíduos com doença cardíaca. Resultados: A amostra foi caracterizada por indivíduos com idade ≥ 50 anos, não-fumantes (56,2%), fisicamente inativos (57,25%). O nível de não compreensão foi de menos de 10 % da amostra. As dúvidas foram prevalentes em indivíduos com doença cardíaca (75%) em relação ao nível de fadiga causada ao executar uma tarefa. Conclusão: O DASI foi traduzido e adaptado para o Português Brasileiro com sucesso. Introdução: O Estudo 2 teve como objetivo a realização de uma revisão sistemática e metanálise dos efeitos EENM sobre as medidas ergoespirométricas: consumo de oxigênio no pico do exercício (VO2pico), consumo de oxigênio no limiar ventilatório (VO2LV), freqüência cardíaca pico (FCpico) e potência em pacientes com IC. Métodos: Foi realizada uma busca sistemática, sem restrição de data ou idioma nas bases de dados Medline, mbase.com, Cochrane Central Register of Controlled Trials, CINAHL, Amedeo e Pedro. Foram incluídos ensaios clínicos randomizados, com ou sem estratégia de cruzamento, de intervenções baseadas na EENM utilizando eletrodos de superfície para produzir uma contração muscular comparativamente aos cuidados médicos habituais ou exercício em indivíduos com IC. Os estudos foram classificados de forma independente para a qualidade (Jadad, Pedro e Escala de Qualidade da Pesquisa). Para avaliação do efeito da intervenção foi utilizado forest plot, mean difference, teste Z e p-valor (≤0,05). A heterogeneidade foi avaliada através do teste quiquadrado e o viés de publicação foi avaliado de forma qualitativa (Begg’s funnel plots) e quantitativamente (Egger’s regression). Resultados: Primeira revisão sistemática com metanálise que analisou o impacto da EENM no VO2pico, VO2LV, FCpico e potência em pacientes com IC, sendo que esta proporciona ganhos semelhantes na potência em comparação com o exercício ou tratamento habitual, e produz efeitos benéficos sobre o VO2pico, VO2LV, FCpico, mas não maiores do que o exercício. Conclusão: A EENM melhora no desempenho do TECP e, portanto, pode ser uma intervenção terapêutica valiosa, alterando positivamente a trajetória clínica dos pacientes com IC. _________________________________________________________________________________________________ ABSTRACT / Introduction: Study 1 aimed to develop a Brazilian version of the Duke Activity Status Index (DASI) and culturally adapt this instrument for indirect assessment of CRC in patients with cardiovascular disease in Brazil. Methods: The translation process involved four stages: initial translation, back translation, multidisciplinary committee review and previous testing with 16 individuals (8 cardiac patients and 8 healthy subjects). The chi- square and Mann-Whitney tests were used to determine differences between controls and individuals with heart disease. Results: The sample was characterized by individuals aged ≥ 50 years, non-smokers (56.2 %), physically inactive (57.25 %). The level of non-understanding was less than 10% of the sample. Doubts were prevalent in individuals with heart disease (75 %) compared to the level of fatigue caused to perform a task. Conclusion: The DASI was successfully translated and adapted to Brazilian Portuguese. Introduction: Study 2 aimed to conduct a systematic review and meta-analysis of the effects of NMES on ergospirometric measures: oxygen consumption at peak exercise (VO2peak), oxygen consumption at the ventilator threshold (VO2LA), peak heart rate (HRpeak) and peak workload (PW) in HF patients. Methods: A systematic search without language or date restriction was performed in data bases: Medline, Embase.com, Cochrane Central Register of Controlled Trials, CINAHL, Amedeo and Pedro. Were included randomized clinical trials, with or without crossover strategy based on interventions with NMES using surface electrodes to produce a muscle contraction compared to usual medical care or aerobic exercise in HF patients. Studies were classified independently for quality (Jadad, Pedro and Quality Scale Research). To evaluate the effect of intervention were used forest plot, mean difference, Z test and p-value (≤ 0.05). Heterogeneity was assessed using the chisquared test and publication bias was assessed qualitatively (Begg's funnel plots) and quantitatively (Egger's regression). Results: First systematic review with meta-analysis that examined the impact of NMES in VO2peak , VO2AT , HRpeak and PW in HF patients, demonstrating that NMES provides similar improvement in PW compared with exercise or usual care, and produces beneficial effects on VO2peak , VO2AT , HRpeak, but not greater than exercise. Conclusion: NMES improved performance CPX and therefore viii may be a valuable therapeutic intervention, positively altering the clinical course of HF patients.
40

Influência de correntes de média e baixa frequência e da dobra cutânea sobre o desconforto sensorial e o pico de torque extensor do joelho / Influence of medium and low frequency currents and of skinfold on sensory discomfort and knee joint torque

Medeiros, Flávia Vanessa de Araújo 05 August 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação Stricto-Sensu em Educação Física, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2015-01-26T19:15:07Z No. of bitstreams: 1 2014_FlaviaVanessadeAraujoMedeiros_Parcial.pdf: 1618537 bytes, checksum: a3daf8316b2aa321fca6131f83675bf5 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2015-01-30T15:41:27Z (GMT) No. of bitstreams: 1 2014_FlaviaVanessadeAraujoMedeiros_Parcial.pdf: 1618537 bytes, checksum: a3daf8316b2aa321fca6131f83675bf5 (MD5) / Made available in DSpace on 2015-01-30T15:41:27Z (GMT). No. of bitstreams: 1 2014_FlaviaVanessadeAraujoMedeiros_Parcial.pdf: 1618537 bytes, checksum: a3daf8316b2aa321fca6131f83675bf5 (MD5) / Contextualização: Tem sido afirmado que a corrente de média frequência é mais eficaz do que a corrente de baixa frequência para a induzir elevado torque articular com baixo desconforto sensorial; e que a espessura da dobra cutânea (EDC) pode influenciar na eficiência da eletroestimulação neuromuscular (EENM). Entretanto, existem poucos estudos comparativos sobre o tema. Objetivo: Investigar os efeitos de duas correntes de média frequência (AUS1 e AUS2), duas de baixa freqüência (FES1 e FES2) e da EDC sobre o desconforto e o torque isométrico extensor do joelho. Métodos: O estudo foi dividido em duas partes: 1) Comparação do torque evocado por cada uma das correntes e do grau de desconforto percebido durante e imediatamente após a EENM. 2) investigação dos efeitos da EDC sobre as variáveis analisadas em dois subgrupos G1(EDC menor) e G2 (EDC maior). Resultados: Parte 1: FES1 evocou torque 21% superior a FES2 e 23% superior a AUS2. AUS1 induziu torque 21% superior a FES2 e 22% superior a AUS2 (p<0,01 em todas as comparações). Não houve diferença significativa entre FES1 e AUS1, bem como entre AUS2 e FES2 (p>0,05 nas duas comparações). Correntes com maior largura de pulso foram mais desconfortáveis que correntes com menor largura de pulso. Parte 2: G1 evocou torque 28% superior ao G2 (p<0,01), o desconforto eliciado pela EENM não diferiu significativamente entre os subgrupos (p=0,425). Conclusão: Parte 1: correntes com maior largura de pulso eliciam maior torque articular com maior desconforto. Parte 2: a EDC influencia na magnitude do torque evocado e na intensidade de corrente requerida, mas não na percepção de desconforto. / Background: It has been supposed that the medium frequency current is more effective than low frequency current to induce torque with less sensory discomfort and that skinfold thickness (SFT) can to influence on efficacy of neuromuscular electrical stimulation (NMES). However, there have been few comparative studies on the subject. Objective: To investigate the effects of two medium frequency currents (AUS1 and AUS2), two low frequency currents (FES1 and FES2) and SFT on discomfort and on the isometric knee extensor torque. Methods: The study was divided into two parts: 1) Comparison of the torque evoked by each of the currents and the degree of discomfort perceived during and immediately after the NMES. 2) investigation of the effects of skinfold thickness on the variables analysed into two subgroups G1 (lower skinfold thickness) and G2 (larger skinfold thickness). Results: Part 1: FES1 evoked torque 21% higher than FES2 (p<0,01) and 23% higher than AUS2 (p<0,01). AUS1 induced torque 21% higher than FES2 (p<0,01). Currents with smaller pulse width (FES2 and AUS2) are more comfortable than currents with higher pulse width (FES1 and AUS1). Part 2: There are significant differences between the subgroups in relation to the NMES-evoked torque; the intensity of the current correlates positively with the skinfold thickness, negatively with the evoked torque and does not correlate with the induced discomfort. Conclusion: Part 1: currents with greater pulse width induce greater joint torque with greater discomfort. Part 2: G1 evoked torque 28% higher than G2 (p<0,01), the discomfort elicited by NMES did not differ significantly between subgroups.

Page generated in 0.0859 seconds