• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 26
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 83
  • 83
  • 83
  • 40
  • 39
  • 20
  • 20
  • 18
  • 17
  • 15
  • 15
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Técnicas de análise genômica permitem estabelecer o diagnóstico etiológico de crianças com baixa estatura de causa desconhecida / Genomic analysis techniques allow the establishment of etiological diagnosis in short stature children of unknown cause

Homma, Thaís Kataoka 06 June 2019 (has links)
INTRODUÇÃO: Crianças com baixa estatura constituem um grupo heterogêneo. Em uma parcela dos casos, o mecanismo envolvido nesse processo decorre de alterações genéticas. OBJETIVO: Realizar uma investigação clínica e genético-molecular de um grupo de pacientes com baixa estatura de causa desconhecida. MÉTODOS: Selecionamos crianças com baixa estatura persistente (escore-Z de altura <= -2 para idade e sexo) de causa desconhecida para avaliação genômica. O estudo foi dividido em 2 etapas: 1ª etapa - avaliação de 229 pacientes com baixa estatura sindrômica [baixa estatura associada a outros achados dismórficos (atraso de desenvolvimento neuropsicomotor e/ou déficit intelectual, presença de dismorfismos faciais e/ou outras malformações)] por cariótipo molecular (aCGH/SNPa); 2ª etapa: avaliação de 99 crianças com baixa estatura persistente, nascidas pequenas para idade gestacional (PIG - escore-Z de peso e/ou comprimento ao nascer <= -2 para idade gestacional) e classificação de acordo com a presença ou ausência de dismorfismos associados. Essas crianças foram divididas em dois grupos: baixa estatura sindrômica (n=44) e baixa estatura isolada (n=55). Pacientes com baixa estatura sindrômica foram avaliados por sequenciamento exômico (WES). Pacientes com baixa estatura isolada foram avaliados através de painel gênico (n = 39) ou WES (n = 16). RESULTADOS: 1ª etapa: 32 (14%) pacientes com baixa estatura sindrômica apresentaram variações no número de cópias (CNVs) patogênicas ou possivelmente patogênicas. Sete delas são recorrentes em outros estudos e são responsáveis por cerca de 40% de todas as CNVs patogênicas/possivelmente patogênicas encontradas em pacientes com baixa estatura de causa desconhecida. 2ª fase: Dentre os 99 pacientes avaliados com baixa estatura nascidos PIG, foram encontradas 23 variantes patogênicas/possivelmente patogênicas em genes já associados à distúrbios de crescimento. Quinze (34%) nos pacientes com baixa estatura sindrômica, em genes relacionados a processos celulares fundamentais, vias de reparo de DNA e vias intracelulares; e oito (15%) em pacientes com baixa estatura isolada, em genes associados à cartilagem de crescimento e a via RAS/MAPK. CONCLUSÃO: A heterogeneidade dos pacientes com baixa estatura dificulta o diagnóstico clínico. As novas abordagens genômicas permitem estabelecer o diagnóstico etiológico de crianças com baixa estatura de causa desconhecida / BACKGROUND: Patients born small for gestational age (SGA) are a heterogenous group, and in several cases, it is due to genetic processes. AIM: To perform a clinical and genetic-molecular investigation of short stature patients of unknown cause. METHODS: We selected short stature children (height <= -2 SDS for age and sex) of unknown cause for genomic evaluation. The study had two stages: 1st stage - 229 syndromic short stature patients (patients with short stature and dysmorphic features, developmental delay, and/or intellectual disability) were evaluated by molecular karyotype (aCGH/SNPa); 2nd stage: We selected 99 short stature children born SGA (birth weight and/or length <=-2 SDS for gestational age). They were classified according to the presence or absence of dysmorphic features into two groups: syndromic short stature (n=44) and isolated short stature (n=55). Patients with syndromic short stature were evaluated by whole exome sequencing (WES), and patients with isolated short stature were evaluated through a target panel sequencing (n=39) or WES (n=16). RESULTS: 1st stage: 32 (14%) syndromic short stature patients had pathogenic or probably pathogenic copy number variations (CNVs). We observed seven recurrent CNVs that are responsible for about 40% of all pathogenic/probably pathogenic genomic imbalances found in short stature patients of unknown cause. 2nd stage: Of the 99 patients evaluated, 23 pathogenic/likely pathogenic variants were found in genes already associated with growth disorders. Fifteen (34%) syndromic short stature patients had pathogenic variants in genes related to fundamental cellular processes, DNA repair and intracellular pathways; and eight (15%) isolated short stature patients had pathogenic variants in genes associated with growth plate development and the RAS/MAPK pathway. CONCLUSION: The heterogeneity of short stature makes the clinical diagnosis difficult. The new genomic approaches are effective to diagnose a larger number of undiagnosed patients
62

Gestações gemelares com pesos discordantes: estudo da predição ultra-sonográfica e dos resultados neonatais / Twin growth discordance: sonographic prediction and factors related to perinatal outcome

Machado, Rita de Cassia Alam 01 November 2006 (has links)
A gemelaridade apresenta algumas intercorrências específicas, como a discordância de peso entre fetos e recém-nascidos (RNs). O objetivo do presente estudo foi predizer a discordância de peso do exame ultra-sonográfico comparada à do parto e avaliar a morbidade e a mortalidade neonatais nas gestações gemelares discordantes quanto ao peso. Este foi um estudo retrospectivo, com levantamento dos casos do período de 1998 a 2004, no Setor de Gestações Múltiplas da Clínica Obstétrica do HCFMUSP. Na avaliação da predição ultra-sonográfica, foram inseridas 221 gestações gemelares e, na avaliação da morbidade e da mortalidade, 151 gestações com partos nessa instituição. A discordância de peso foi definida como >= 20%, sendo excluídos os casos de malformações fetais (n=43) e da Síndrome da transfusão feto-fetal (n=24). Para análise da adequação do peso ao nascimento, utilizou-se a curva de Alexander et al., 1998, para gêmeos. No estudo da predição, foram utilizados quatro intervalos de tempo em relação ao parto (0 a 7 dias - n = 96; 8 a 14 dias - n = 66; 15 a 21 dias - n = 58; 22 a 28 dias - n = 59 gestações), somando 279 avaliações. No grupo de 0 a 7 dias, a estimativa da sensibilidade foi de 93,6%, especificidade de 79,4%, valor preditivo positivo de 89,2%, valor preditivo negativo de 87,1% e acurácia de 88,6%. Nos demais grupos, a sensibilidade e a acurácia foram de 95,8% e 84,9%, 95,6% e 84,5%, 90,9% e 84,8%, respectivamente. Em relação à morbidade, 111 gestações eram concordantes (73,5%) e 40 discordantes quanto ao peso. No grupo discordante, 75% das gestações gemelares apresentaram pelo menos um recém-nascido com Restrição de Crescimento Fetal (RCF). Nesta análise, as gestações gemelares concordantes monocoriônicas obtiveram menor média de idade gestacional no parto (34,3 versus 36,2 semanas, p=0,004), menor peso médio (2067 versus 2334 gramas, p=0,0016) e maior tempo de internação (10,6 versus 7,3 dias, p=0,0023) que as gestações concordantes dicoriônicas. Nas gestações discordantes, não houve diferença significativa em relação à corionicidade. As gestações discordantes, com pelo menos um RN abaixo do percentil 10, apresentaram menor média de idade gestacional (35,2 versus 36,8 semanas, p=0,009) e maior tempo de internação (17,5 versus 8,2 dias, p=0,026). Não foi observada diferença significativa de morbidade e mortalidade entre RNs concordantes e discordantes, com pesos entre os percentis 10 e 90. Os fetos menores das gestações discordantes demonstraram maior freqüência de índice de Apgar inferior a 7 (27,5% versus 7,5%, p=0,01). A avaliação da mortalidade não demonstrou diferença significativa em relação aos grupos concordantes (3,7%) e discordantes (4,5%; p = 1,00). No presente estudo, conclui-se que os quatro grupos apresentaram adequada correlação entre a discordância de peso à ultra-sonografia e no nascimento, porém com melhor predição até sete dias antes do parto. A morbidade neonatal esteve relacionada à RCF do menor feto. A discordância de peso e a corionicidade não interferiram na mortalidade neonatal. / The aim of this study was to evaluate the ability of prenatal ultrasound scans to predict fetal growth discordance in twin pregnancies and perinatal morbidity/mortality associated with these cases. This was a retrospective study (1998-2004) involving twin pregnancies that were scanned and had their delivery at our Institution (HCFMUSP). Cases with fetal malformations (n=43) or twin to twin transfusion syndrome (n=24) were excluded. The study of ultrasound scans consisted of 221 twin pregnancies. The final morbidity/mortality study group consisted of 151 twin pregnancies. Birth weight was evaluated based on twin growth charts published by Alexander et al (1998) and weight discordance as a difference >= 20%. Small for gestacional age (SGA) was defined as birth weight below the 10th centile. The study of ultrasonographic prediction of interwin discordance was made using four different intervals between ultrasound examination and delivery (0 to 7 days, n = 96; 8 to 14 days, n = 66; 15 to 21 days, n = 58; 22 to 28 days, n = 59 pregnancies), with a total of 279 ultrasound examinations. In group 0 to 7 days, the sensitivity was 93,6%, specificity was 79,4%, positive predicted values was 89,2%, negative predicted values was 87,1% and accuracy was 88,6%. In the groups 8 to 14 days, 15 to 21 days and 22 to 28 days the sensitivity and accuracy were 95,8% and 84,9%, 95,6% and 84,5%, 90,9% and 84,8%, respectively. Birthweight discordance was observed in 40 sets of twins (26.5%) and 12 cases were monochorionic MC (30%). Twenty five cases (22.5%) in the non discordant group were MC. In the non discordant group, monochorionic pregnancies showed lower gestational age at delivery (34.3 versus 36.2 wks, p=0.004), lower mean birth weight (2067g versus 2334g, p=0.0016) and longer length of stay in hospital (10.6 versus 7.3 days, p=0.0023) compared to dichorionic twins. In the group with twin birthweight discordance, there were no significant differences between MC and DC pregnancies and 75% of the cases had at least one newborn with SGA. These cases were showed lower gestational age at delivery (35.2 versus 36.8wks, p=0.009) and longer length of stay in hospital (17.5 versus 8.2 days, p=0.026). In the discordant group, the smaller twin had a higher frequency of first minute Apgar score < 7 (27.5% versus 7.5%, p=0.01). Perinatal mortality rate was similar in both groups (discordant 4.5% and concordant 3.7%, p=1.0). There were no significant differences in morbidity and mortality between concordant and discordant twins when birth weight was between the 10 th and 90 th centile. In conclusion, there was a good correlation between fetal growth discordance predicted by prenatal scan and actual birth weight discordance. Neonatal morbidity was related to SGA. Excluding fetal malformation and TTTS cases, birth weight discordance in twin pregnancies is not a significantly associated with neonatal mortality.
63

Caracterização da insensibilidade ao fator de crescimento insulina-símile tipo 1 em pacientes com defeitos no receptor tipo 1 de IGFs (IGF-1R) / Characterization of an insensitivity to type 1 insulin-like growth factor in patients with defects in the type 1 IGF receptor (IGF-1R)

Leal, Andréa de Castro 13 September 2012 (has links)
Introdução: Crianças nascidas pequenas para a idade gestacional (PIG) apresentam maior risco de permanecerem com baixa estatura na vida adulta. Os fatores de crescimento insulino-símile tipo 1 e 2 (IGF-1 e IGF-2) são os principais fatores endócrinos determinantes do crescimento fetal. A maioria das ações conhecidas destes hormônios é mediada via um receptor tirosina quinase, conhecido como IGF-1R. As mutações inativadoras e deleções do gene do IGF1R em heterozigose vêm sendo relatadas de forma crescente nos últimos 9 anos em pacientes com história de déficit de crescimento pré e pós-natal. Postula-se que pelo menos 2 a 3% das crianças nascidas PIG poderiam apresentar defeitos no IGF1R. O quadro clínico destes pacientes apresenta grande variabilidade quanto à gravidade do retardo de crescimento pré- e pós-natal e aos parâmetros hormonais. Objetivo: Caracterizar in vitro a resistência ao IGF-1 de pacientes com defeitos no IGF1R, identificados em nosso ambulatório. Material e métodos: Desenvolvemos cultura de fibroblastos de 2 controles (C1 e C2) e de 4 pacientes nascidos PIG (SGA1, SGA2, SGA3 e SGA4) com suspeita de insensibilidade ao IGF-1 por ausência de recuperação do crescimento na vida pós natal. Destes pacientes, um paciente (SGA1) era portador de mutação missense em heterozigose no gene IGF1R (p.Arg511Trp) e os demais apresentavam baixa expressão dos IGF1R em leucócitos periféricos quando avaliados por PCR em tempo real. Um destes pacientes (SGA2) apresentava também a variante alélica p.Gly6Arg do IGF1R em heterozigose, alteração esta encontrada também em controles e familiares sem déficit de crescimento. As ações do IGF-1 foram determinadas por ensaios de proliferação, análise da expressão do IGF-1R e estudos de fosforilação de proteínas da via de sinalização do IGF-1 em fibroblastos (via PI3K). Resultados: As linhagens SGA1, SGA2, SGA3 e SGA4 proliferaram respectivamente 55%, 66%, 64% e 28% a menos sob estímulo de IGF-1 em relação ás linhagens controles. No estudo da expressão do RNAm do IGF1R por PCR em tempo real, foi observada redução na expressão do IGF1R nas linhagens SGA2, SGA3 e SGA4 em relação aos controles, assim como o conteúdo total da proteína IGF-1R. Por outro lado, a linhagem SGA1 mostrou expressão aumentada do IGF1R e no conteúdo da proteína em relação aos controles. Em relação á ativação da via PI3K, todas as linhagens dos pacientes apresentaram menor fosforilação de AKT após estímulo com IGF-1, quando comparadas com as linhagens controles. Conclusão: Demonstramos a presença de insensibilidade parcial ao IGF-1 nas linhagens estudadas. A baixa expressão do IGF1R observada em leucócitos periféricos nas linhagens SGA2, SGA3 e SGA4 foi confirmada em fibroblastos tanto em nível de RNAm quanto da sua proteína. Nestas linhagens a insensibilidade ao IGF-1 é secundária a diminuição da expressão deste receptor. Em contraste a na linhagem com a mutação p.Arg511Trp (SGA1) observou-se expressão normal do IGF-1R na superfície celular. Pacientes com alterações no gene IGF1R não apresentam um fenótipo característico que os diferencie de outras crianças nascidas PIG sem alterações neste gene, mostrando a importância dos estudos moleculares neste grupo de pacientes / Small for gestational age (SGA) children are at a greater risk of having a short stature in adulthood. The type 1 and 2 insulin-like growth factors (IGF-1 and IGF-2) are the main endocrine factors determining fetal growth, and most of the known actions of these hormones are mediated via a receptor tyrosine kinase, IGF-1R. Inactivating mutations and deletions of the IGF1R gene in heterozygosis have been reported with increasing frequency in the last 9 years in patients with a history of a failure to thrive pre- and postnatally. It is postulated that at least 2-3% of the children born SGA could be defective for the IGF1R. The clinical presentation of these patients is highly variable with regard to the severity of growth retardation and pre- and post-natal hormonal parameters. Objectives: The goal of this study was to identify the in vitro insensitivity to IGF-1 in patients with defects in IGF1R. Methods: We developed fibroblast cultures from two controls (C1 and C2) and 4 patients born SGA (SGA1, SGA2, SGA3 and SGA4) with a suspected insensitivity to IGF-1 by the absence of catch-up growth during their postnatal life. Of these patients, one (SGA1) carried a heterozygous missense mutation in the IGF1R gene (p.Arg511Trp), and the others exhibited low expression levels of IGF1R in their peripheral leukocytes, as evaluated using real-time PCR. One of these patients (SGA2) was also heterozygous for the allelic variant p.Gly6Arg of IGF1R, an alteration also found in the controls and family members not displaying growth restriction. The actions of IGF-1 were determined using proliferation assays, an analysis of the expression of IGF- 1R and phosphorylation studies of proteins of the IGF-1 signaling pathway in fibroblasts (via PI3K).Results: The SGA1, SGA2, SGA3 and SGA4 fibroblasts proliferated 55%, 66%, 64% and 28%, respectively, less under the stimulation of IGF-1 compared to the control lines. Using real-time PCR, the IGF1R mRNA expression showed reduced levels of IGF1R in the SGA2, SGA3 and SGA4 cells compared to the controls, and the total IGF-1R protein was also decreased in these cells. Moreover, the SGA1 cells showed increased expression levels of IGF1R mRNA and protein compared to the controls. In relation to the activation of PI3K, all of the cells showed decreased phosphorylation of AKT after the stimulation with IGF-1 compared to the control cells. Conclusion: We demonstrated the presence of a partial insensitivity to IGF-1 in the studied samples. The low expression of IGF1R observed in the peripheral leukocytes in the SGA2, SGA3 and SGA4 fibroblasts was confirmed at both the mRNA and protein levels, and the Andréa de Castro Leal Doutorado insensitivity of the cells to IGF-1 is secondary to the decreased expression of the receptor. In contrast, the cells with the mutation p.Arg511Trp (SGA1) displayed normal IGF-1R expression on the cell surface. The patients with alterations in the IGF1R gene do not exhibit a characteristic phenotype that differentiates them from other children born SGA and with no changes in this gene, thus showing the importance of molecular studies for this group of patients
64

Variações no número de cópias cromossômicas submicroscópicas como causa de baixa estatura de início pré-natal / Submicroscopic chromosomal copy number variants as a cause of prenatal onset short stature

Canton, Ana Pinheiro Machado 13 April 2015 (has links)
A pesquisa de variações no número de cópias (CNVs; copy number variants) cromossômicas tem revelado o importante papel destas alterações genômicas na diversidade populacional e na etiologia de doenças humanas. O modelo de associação de CNVs a doenças envolve deleções e/ou duplicações individualmente raras, mas com segmentos cromossômicos de tamanhos relevantes. Os pacientes com baixa estatura de início pré-natal constituem um grupo heterogêneo com quadros clínicos complexos frequentemente resultantes de alterações genéticas, que, desde o período intrauterino, perturbam os mecanismos e vias de desenvolvimento e crescimento fetais. Assim sendo, aventamos a hipótese de que CNVs raras possam estar entre as causas genéticas de baixa estatura de início prénatal. Para tanto, nosso estudo visou avaliar a presença de deleções ou duplicações submicroscópicas em um grupo selecionado de pacientes nascidos pequenos para idade gestacional (PIG) com baixa estatura persistente sem causa definida. Foram avaliados 51 pacientes nascidos PIG com baixa estatura persistente após o 4º ano de vida que apresentavam dismorfismos, atraso de desenvolvimento neuropsicomotor (DNPM) ou deficiência intelectual, porém sem caracterizar síndromes conhecidas e com cariótipo normal. Amostras de DNA dos pacientes foram submetidas à hibridização genômica comparativa por microarray (aCGH; array comparative genomic hybridization) baseada em oligonucleotídeos na plataforma 60K. Os achados foram comparados com CNVs descritas em bancos de dados de controles normais. Foram identificadas 18 CNVs, ausentes em controles saudáveis, em 17 dos 51 pacientes (33%). As alterações foram avaliadas para classificação de sua patogenicidade de acordo com os seguintes critérios: 1) padrão de herança e segregação familiar; 2) sobreposição a coordenadas genômicas de síndromes conhecidas; 3) sobreposição a CNVs patogênicas descritas em banco de dados; 4) e conteúdo gênico. Quatro CNVs, encontradas em 3 pacientes, foram classificadas como patogênicas: 1) del 22q11.21; 2) dup 10q26.2-26.3 e del 10q26.3; e 3) del 4q28.2-q31.21. Cinco CNVs, encontradas em 5 pacientes, foram classificadas como provavelmente patogênicas: 4) del 3q27.1-q27.3; 5) del 20p13; 6) dup 14q11.2-q12; 7) dup 16q24.1-q24; e 8) dup Xq31.1-q13.2. Somando os grupos, encontramos CNVs patogênicas ou provavelmente patogênicas em 16% do total de pacientes. De acordo com a segregação familiar, 4 variações foram consideradas de significado clínico incerto, enquanto 5 foram benignas. Para estabelecer uma relação causal genótipo-fenótipo e identificar genes associados a baixa estatura de início pré-natal, foi realizada uma análise ampla do conteúdo gênico das variações classificadas como patogênicas, provavelmente patogênicas ou de significado clínico incerto, através do uso de efetivas ferramentas de bioinformática. Nossos resultados nos levam às seguintes conclusões: 1) a frequência de CNVs patogênicas e provavelmente patogênicas no estudo foi de 16%, evidenciando que CNVs raras provavelmente estão entre as causas genéticas de baixa estatura de início pré-natal; 2) o aCGH permitiu a elucidação do diagnóstico e das bases genéticas envolvidas no fenótipo em 8 pacientes selecionados; e 3) foram encontradas CNVs em diferentes regiões cromossômicas, com diferentes genes candidatos, que podem estar envolvidos nos mecanismos de regulação do crescimento e/ou nas vias regulatórias de desenvolvimento intrauterino / Analysis of chromosomic copy number variants (CNVs) have demonstrated the important role of these genomic imbalances in population diversity and human disease. The model of CNV disease association involves deletions and/or duplications that are individually rare but encompass chromosomal segments of relevant size. Prenatal onset short stature patients constitute a complex group characterized by clinical heterogeneity. The causes of prenatal growth impairment frequently involve genetic changes that disturb the mechanisms and the pathways of fetal growth and development. Thus, we hipothesized that rare CNVs might contribute to the genetic etiology of prenatal onset short stature. In order to evaluate this assumption, our study analyzed the presence of submicroscopic deletions and/or duplications in a selected group of patients born small for gestational age with persistent short stature but without a recognized cause. A total of 51 patients with prenatal and postnatal growth retardation associated with dysmorphic features, developmental delay and/or intellectual disability, but without criteria for known syndromes, were selected. All patients had normal G-banded karyotyping. Array-based comparative genomic hybridization (aCGH) in a whole-genome 60K platform was performed using DNA obtained from all patients. Detected CNVs were compared with CNV data from healthy controls individuals, excluding common copy number polymorphisms. In 17 of the 51 patients screened (33%), 18 rare CNVs were identified. The pathogenicity of CNVs was assessed by considering the following criteria: inheritance and familial segregation; overlap with genomic coordinates for a known genomic imbalance syndrome; overlap with CNVs previously identified in other patients with prenatal onset short stature; and gene content. Four distinct CNVs, found in three patients, were classified as pathogenic: 1) del 22q11.21; 2) dup 10q26.2-26.3 and del 10q26.3; and 3) del 4q28.2-q31.21. Five CNVs, found in five patients, were classified as probably pathogenic: 4) del 3q27.1-q27.3; 5) del 20p13; 6) dup 14q11.2-q12; 7) dup 16q24.1-q24; and 8) dup Xq31.1-q13.2. Taken both groups together, we found pathogenic or probably pathogenic CNVs in 16% of patients. According to familial segregation, four variants were considered as variants of uncertain clinical significance, while five variants were considered as benign. In an attempt to establish a causal genotype-phenotype correlation and to identify genes involved in growth impairment of prenatal onset, the gene content of the variants was analyzed using bioinformatics tools for gene prioritization. Based on our results, it is possible to make the following conclusions: 1) the frequency of pathogenic or probably pathogenic CNVs was at least 16%, indicating that rare CNVs are probably among the genetic causes of prenatal onset short stature; 2) aCGH clarified the diagnosis and the genetic etiology involved in the phenotype of 8 selected patients; and 3) we found CNVs in distinct chromosomal regions with several candidate genes that may be involved in the mechanisms of growth regulation and/or in the regulatory pathways of intrauterine development
65

Gastrosquise: avaliação do padrão de crescimento fetal e predição de baixo peso no nascimento / Fetal gastroschisis: evaluation of pattern and prediction of low birth weight

Centofanti, Sandra Frankfurt 08 October 2014 (has links)
INTRODUÇÃO: Gastrosquise é uma malformação da parede abdominal do feto e uma das principais complicações relacionadas à restrição de crescimento fetal. Objetivo principal: avaliar o padrão de crescimento de fetos com gastrosquise para cada parâmetro biométrico. Objetivo secundário: avaliar o déficit de crescimento em três períodos gestacionais e predizer recém-nascidos pequenos para idade gestacional a partir de medidas de parâmetros biométricos abaixo do percentil 10. MÉTODOS: Este é um estudo do tipo coorte retrospectivo. Foram selecionados 70 casos para avaliação do padrão de crescimento. As medidas de cada parâmetro biométrico: circunferência cefálica, circunferência abdominal, comprimento femoral, razão circunferência cefálica/circunferência abdominal e peso fetal estimado foram plotadas em um gráfico de dispersão para comparação com a curva de referência. A diferença porcentual entre as médias das medidas dos fetos com gastrosquise em relação aos normais foi determinada. Para a avaliação do déficit de crescimento foram incluídos 59 casos, com ao menos um exame em cada período gestacional (I:20 a 25 semanas e 6 dias; II:26 a 31 semanas e 6 dias; III: 32 semanas até o parto). O déficit de cada parâmetro biométrico foi obtido a partir da comparação entre os períodos gestacionais. Para a predição de recém-nascido pequeno para idade gestacional foram utilizadas as medidas abaixo do percentil 10 de cada parâmetro biométrico nos períodos I e II. RESULTADOS: Na avaliação do padrão de crescimento, observa-se diferença significativa entre os fetos com gastrosquise e fetos normais a partir de 20 semanas de gestação (p<0,005). Na avaliação do déficit de crescimento, apenas peso fetal estimado apresentou diferença significativa (p=0,030). O porcentual de fetos com peso fetal estimado abaixo do percentil 10 no período 2 foi 40% maior do que no período 1, e 93% maior no período 3 do que no 1. Na predição de recémnascidos pequeno para idade gestacional, apenas a circunferência cefálica (razão chance= 6.07; sensibilidade= 70.8%; especificidade= 71.4%) e a circunferência abdominal (razão chance=0,558; sensibilidade= 41,7%; especificidade= 80%) no período II, foram consideradas. CONCLUSÃO: Fetos com gastrosquise apresentam medidas dos parâmetros biométricos significativamente menores do que as de fetos normais, a partir de 20 semanas de gestação. Na avaliação do déficit de crescimento, observa-se maior incidência de restrição de crescimento fetal nos períodos II e III em comparação ao período I. É possível predizer recém-nascidos com baixo peso ao nascimento, a partir de medidas de circunferência cefálica e circunferência abdominal, abaixo do percentil 10 no período II / INTRODUCTION: Gastroschisis is a congenital abdominal wall defect of the fetus and one of its main complications is related to fetal growth restriction. OBJECTIVES: Primary: To evaluate the growth pattern of fetuses with gastroschisis according to each biometric parameter; Secondary: to evaluate growth deficit in three gestational periods and to predict low birth weight from measures of biometric parameters below the 10th percentile. METHODS: This is a retrospective cohort study. We selected 70 cases for evaluation of the growth pattern. The measurements of each biometric parameter: head circumference, abdominal circumference, femur length, head circumference/abdominal circumference ratio and estimated fetal weight were plotted in a growth chart for comparison with the curve of normality. The percentage difference between the mean values of the fetuses with gastroschisis in relation to normal fetuses was then determined. For the evaluation of growth deficit 59 cases with at least one exam in each gestational period (I: 20 to 25 weeks and 6 days; II: 26 to 31 weeks and 6 days; III: 32 weeks until delivery) were included. The deficit of each biometric parameter was obtained from the comparison between these gestational periods. For the prediction of low birth weight, the measures below the 10th percentile of each biometric parameter in periods I and II were tested. RESULTS: In the evaluation of the growth pattern a significant difference between the fetuses with gastroschisis and normal fetuses from 20 weeks of gestation (p < 0.005) is observed. In the evaluation of growth deficit only estimated fetal weight showed a significant difference (p= 0.030). The percentage of fetuses with estimated fetal weight values below 10 percentile in period 2 was 40% higher than that in period I, and 93% higher in period III than in I. In the prediction of low birth weight, only head circunference (odds ratio= 6.07; sensitivity= 70.8 %; specificity = 71.4 %) and abdominal circunference (odds ratio= 0.558; sensitivity = 41.7 %; specificity = 80 %) in period II were predictive. CONCLUSION: Fetuses with gastroschisis show biometric parameters measures significantly smaller than the measures of normal fetuses with 20 weeks of gestation and/or more. In the evaluation of growth deficit, there is a higher incidence of fetal growth restriction in periods II and III. It is possible to predict newborns with low birth weight from measures of head circunfernce and abdominal circunference below the 10th percentile in period II
66

Avaliação do volume e da vascularização renais ao ultrassom tridimensional em fetos com restrição de crescimento intrauterino / Evaluation of fetal renal volume and vascularization with the threedimensional ultrasound in intrauterine growth restriction

Senra, Janaina Campos 21 November 2018 (has links)
INTRODUÇÃO: Na restrição de crescimento intrauterino, a resposta adaptativa a hipóxia, com priorização do fluxo sanguíneo para órgãos nobres, causa vasoconstricção periférica, com aumento da resistência nas artérias renais. Com isso, o desenvolvimento renal é prejudicado e fetos restritos apresentam volumes renais menores. No entanto, a literatura é escassa em estudos que utilizem a ultrassonografia tridimensional na avaliação renal e não descreve a relação desse possível dano renal com desfechos neonatais adversos. Tal técnica tem sido utilizada para mensurar volumes de órgãos e quantificar fluxos sanguíneos de baixa resistência, podendo ser também aplicada para melhorar a avaliação do volume e vascularização renal na restrição de crescimento. OBJETIVOS: Comparar a razão entre o volume renal total e o peso fetal estimado (VRT/PFE) entre fetos com e sem restrição. Além disso, correlacionar o VRT/PFE com a dopplervelocimetria fetal e os índices de vascularização renal e avaliar a associação dos parâmetros renais com eventos neonatais adversos nos fetos restritos. MÉTODOS: O volume total e a vascularização renal de fetos restritos e normais foram avaliados pela ultrassonografia tridimensional e a técnica VOCAL. Os índices de vascularização renal foram corrigidos pela profundidade renal (IVcp, IVFcp and IFcp). Os testes t para amostras independentes e Mann-Whitney foram utilizados para a comparação entre os grupos. Modelos lineares generalizados foram aplicados para avaliar a associação entre as características renais e os eventos neonatais adversos. RESULTADOS: Setenta e um fetos restritos foram comparados a 194 fetos com crescimento normal. O VRT/PFE foi menor no grupo restrito (p < 0,001). Porém essa razão não se correlacionaou com os parâmetros dopplervelocimétricos, os índices vasculares renais ou qualquer evento neonatal adverso. CONCLUSÃO: A razão entre o volume renal total e o peso fetal estimado tende a diminuir na restrição de crescimento intrauterino / INTRODUCTION: In fetal growth restriction, the adaptive response to hypoxia, with prioritization of blood flow to noble organs, causes peripheral vasoconstriction, such as increased resistance in the renal arteries. Then, renal development is impaired and restricted fetuses have lower renal volumes. However, the literature is scarse in studies using three-dimensional ultrasound in renal assessment and does not describe the relationship of this potential renal damage with adverse neonatal outcomes. That technique has been used to mesure volumes and quantify blood flows of low resistance and could also be applied to improve the evaluation of renal volume and vascularization in fetal growth restriction. OBJECTIVES: To compare the ratio of total renal volume to estimated fetal weight (TRV/EFW) among fetuses with and without grown restriction. Fhurthermore, we aim to correlate TRV/EFW with fetal dopplervelocimetry and renal vascularization indexes and to evaluate the association of renal parameters with adverse neonatal events in restricted fetuses. METHODS: Total renal volume and renal vascularization of restricted and normal fetuses were evaluated by three-dimensional ultrasonography and the VOCAL technique. Renal vascularization indexes were corrected for renal depth (VIcd, VFIcd and FIcd). The t-tests for independent samples and Mann-Whitney test were used for comparisons between groups. Generalized linear models were applied to evaluate the association between renal characteristics and adverse neonatal events. RESULTS: Seventy-one restricted fetuses were compared to 194 normally growing fetuses. The TRV/EFW was lower in the restricted group (p < 0.001). However, this ratio did not correlate with Doppler velocimetric parameters, renal vascular indexes or any adverse neonatal events. CONCLUSION: The ratio of total renal volume to estimated fetal weight tends to decrease in intrauterine growth restriction
67

Avaliação do volume e da vascularização renais ao ultrassom tridimensional em fetos com restrição de crescimento intrauterino / Evaluation of fetal renal volume and vascularization with the threedimensional ultrasound in intrauterine growth restriction

Janaina Campos Senra 21 November 2018 (has links)
INTRODUÇÃO: Na restrição de crescimento intrauterino, a resposta adaptativa a hipóxia, com priorização do fluxo sanguíneo para órgãos nobres, causa vasoconstricção periférica, com aumento da resistência nas artérias renais. Com isso, o desenvolvimento renal é prejudicado e fetos restritos apresentam volumes renais menores. No entanto, a literatura é escassa em estudos que utilizem a ultrassonografia tridimensional na avaliação renal e não descreve a relação desse possível dano renal com desfechos neonatais adversos. Tal técnica tem sido utilizada para mensurar volumes de órgãos e quantificar fluxos sanguíneos de baixa resistência, podendo ser também aplicada para melhorar a avaliação do volume e vascularização renal na restrição de crescimento. OBJETIVOS: Comparar a razão entre o volume renal total e o peso fetal estimado (VRT/PFE) entre fetos com e sem restrição. Além disso, correlacionar o VRT/PFE com a dopplervelocimetria fetal e os índices de vascularização renal e avaliar a associação dos parâmetros renais com eventos neonatais adversos nos fetos restritos. MÉTODOS: O volume total e a vascularização renal de fetos restritos e normais foram avaliados pela ultrassonografia tridimensional e a técnica VOCAL. Os índices de vascularização renal foram corrigidos pela profundidade renal (IVcp, IVFcp and IFcp). Os testes t para amostras independentes e Mann-Whitney foram utilizados para a comparação entre os grupos. Modelos lineares generalizados foram aplicados para avaliar a associação entre as características renais e os eventos neonatais adversos. RESULTADOS: Setenta e um fetos restritos foram comparados a 194 fetos com crescimento normal. O VRT/PFE foi menor no grupo restrito (p < 0,001). Porém essa razão não se correlacionaou com os parâmetros dopplervelocimétricos, os índices vasculares renais ou qualquer evento neonatal adverso. CONCLUSÃO: A razão entre o volume renal total e o peso fetal estimado tende a diminuir na restrição de crescimento intrauterino / INTRODUCTION: In fetal growth restriction, the adaptive response to hypoxia, with prioritization of blood flow to noble organs, causes peripheral vasoconstriction, such as increased resistance in the renal arteries. Then, renal development is impaired and restricted fetuses have lower renal volumes. However, the literature is scarse in studies using three-dimensional ultrasound in renal assessment and does not describe the relationship of this potential renal damage with adverse neonatal outcomes. That technique has been used to mesure volumes and quantify blood flows of low resistance and could also be applied to improve the evaluation of renal volume and vascularization in fetal growth restriction. OBJECTIVES: To compare the ratio of total renal volume to estimated fetal weight (TRV/EFW) among fetuses with and without grown restriction. Fhurthermore, we aim to correlate TRV/EFW with fetal dopplervelocimetry and renal vascularization indexes and to evaluate the association of renal parameters with adverse neonatal events in restricted fetuses. METHODS: Total renal volume and renal vascularization of restricted and normal fetuses were evaluated by three-dimensional ultrasonography and the VOCAL technique. Renal vascularization indexes were corrected for renal depth (VIcd, VFIcd and FIcd). The t-tests for independent samples and Mann-Whitney test were used for comparisons between groups. Generalized linear models were applied to evaluate the association between renal characteristics and adverse neonatal events. RESULTS: Seventy-one restricted fetuses were compared to 194 normally growing fetuses. The TRV/EFW was lower in the restricted group (p < 0.001). However, this ratio did not correlate with Doppler velocimetric parameters, renal vascular indexes or any adverse neonatal events. CONCLUSION: The ratio of total renal volume to estimated fetal weight tends to decrease in intrauterine growth restriction
68

Funkcija miokarda leve komore i dnevno-noćni ritam arterijskog krvnog pritiska kod gestacijske hipertenzije / Left ventricular function and circadian rhythm of the arterial blood pressure in gestational hypertension

Ilić Aleksandra 29 June 2015 (has links)
<p>Cilj: Svrha ovog istraživanja je da se odredi uticaj promena u funkciji, morfologiji i geometriji leve komore (LK) i odusustva očuvanog dnevno-noćnog profila krvnog pritiska (KP) na intrauterini zastoj u rastu fetusa (IUGR) i preterminsko zavr&scaron;avanje trudnoće kod gestacijske hipertenzije (GH), reverzibilnost tih promena posle porođaja i povezanost GH sa prisustvom arterijske hipertenzije u porodici. Metodologija: U ovu studiju, koja je koncipirana kao prospektivna, uključeno je 90 trudnica, 30 normotenzivnih, 30 sa GH i dipping profilom KP i 30 sa GH i non-dipping profilom KP. Svim ispitanicama urađen je kompletan dvo-dimenzionalni, pulsni i tkivni Doppler ehokardiografski pregled i ambulatorni 24-h monitoring KP u trećem trimestru trudnoće i 6 nedelja posle porođaja. Rezultati i diskusija: U grupi trudnica sa GH značajno vi&scaron;e su bili poremećeni parametri sistolne, dijastolne i globalne funkcije (EF, s&rsquo;, E, A, E/A, E/e&rsquo;, DTE, IVRT, IVCT, ET, Tei indeks, CO, CW, Ees), morfologije (IVSd, PLWd, RWT, masa miokarda, p&lt;0,0005) i geometrije LK (abnormalna geometrija 67,7% vs 3,3% kod normotenzivnih, p&lt;0,0005). Najizraženije promene bile su u podgrupi non-dippera. Posle porođaja registrovano je značajno popravljanje svih promenjenih ehokardiografskih parametara, a 96,7% ispitanica iz non-dipper podgrupe imale su očuvan dnevno-noćni ritam posle porođaja. U grupi sa GH utvrđeno je postojanje arterijske hipertenzije u porodici u 80% slučajeva u odnosu na 26,7% u kontrolnoj grupi (p&lt;0,0005). Analizom rezultata utvrđeno je da su povećanje maksimalne vrednosti noćnog dijastolnog KP, indeksa mase miokarda i totalne vaskularne rezistence nezavisni prediktori IUGR-a, dok su povećanje prosečne vrednosti noćnog sistolnog KP i indeksa mase miokarda i smanjenje EF nezavisni prediktori preterminskog porođaja. Zaključak: Promene u funkciji i morfologiji leve komore i non-dipping profil KP kod GH imaju prognostički uticaj na pojavu IUGR-a i preterminsko zavr&scaron;avanje trudnoće.</p> / <p>Objective: The purpose of this study was to determine the influence of changes in function, morphology, and geometry of the left ventricle (LV) and a non-dipping arterial blood pressure (BP) pattern on the intrauterine growth restriction (IUGR) and preterm delivery in pregnant women with gestational hypertension (GH), reversibility of these changes after delivery and connection between BP in family with GH. Methods: This prospective study included 90 pregnant women, 30 normotensive, 30 with GH and dipping BP pattern and 30 with GH and non-dipping BP pattern. All participants underwent a complete two-dimensional, pulsed and tissue Doppler echocardiography and 24-h ambulatory blood pressure monitoring in the third trimester and 6 weeks after delivery. Results and discussion: Participants with GH had more impaired parameters of the LV systolic, diastolic and global function (EF, s&rsquo;, E, A, E/A, E/e&rsquo;, DTE, IVRT, IVCT, ET, Tei index, CO, CW, Ees), morphology (IVSd, PLWd, RWT, myocardial mass, p&lt;0,0005) and geometry (abnormal geometry 67,7% vs 3,3% in normotensive, p&lt;0,0005). The greatest changes were noticed in non-dippers. All changed echocardiographic parameters became improved, while 96,7 % non-dipper participants became dipper after delivery. Arterial hypertension in family was present in 80% women with GH vs 26,7% in normotensive (p&lt;0,0005). Analyses revealed that maximum night-time diastolic BP, mass index and total vascular resistance were identified as independent predictors of IUGR. Average systolic night-time BP, mass index and EF were identified as independent predictors of preterm delivery. Conclusion: Changes in LV function, morphology and geometry and a non-dipping pattern of BP in GH predicts IUGR and preterm delivery.</p>
69

Fatores de risco e resultados associados ao baixo peso ao nascimento / Risk factors and outcomes associated to low birth weight

Coutinho, Pedro Ribeiro 30 November 2007 (has links)
Orientador: Jose Guilherme Cecatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-27T12:06:33Z (GMT). No. of bitstreams: 1 Coutinho_PedroRibeiro_M.pdf: 1815537 bytes, checksum: f5725b438362876b5a75c9dc23a340b1 (MD5) Previous issue date: 2007 / Resumo: Introdução: O baixo peso (BP) ao nascimento (<2.500g) constitui-se preocupação em saúde pública especialmente em países em desenvolvimento devido às suas consequências tanto a curto quanto a longo prazo. Justificativa: O estudo dos determinantes e dos resultados maternos e perinatais associados ao BP pode fornecer subsídios para o seu enfrentamento, seja através da aplicação de medidas preventivas primárias e secundárias ou por orientações de políticas de saúde pública que visem à promoção de atenção pré-natal e vigilância ao trabalho de parto adequadas. Objetivos: Avaliar os fatores de risco associados ao BP e seus resultados maternos e perinatais. Métodos: O componente que abordou os fatores associados ao BP teve o desenho de um estudo de caso-controle, enquanto o componente que investigou os resultados e complicações associados ao BP teve o desenho de um estudo de coorte retrospectivo. Foram coletadas informações sobre 43.944 partos realizados no CAISM de 1986 a 2004, armazenadas em banco de dados informatizado da instituição. Foram consideradas todas as gestações acima de 20 semanas que resultaram em recém nascidos (RN) com peso entre 500 e 3.999g. Foram excluídos os casos de natimortos, gestações múltiplas e com peso ignorado. Os RN foram divididos em dois grupos: 1) RN de baixo peso (<2.500g); 2) RN de peso normal (entre 2.500 e 3.999 gramas). Inicialmente foi avaliada a prevalência dos possíveis fatores de risco comparativamente entre casos (baixo peso) e controles, calculando-se o odds ratio (OR) e IC95%. Posteriormente foi calculada a incidência comparativa dos resultados maternos e perinatais de acordo com a presença de baixo peso, estimando-se as razões de risco (RR) e IC95%. Análise de regressão logística múltipla foi também realizada para ambas as abordagens. Resultados: Idade, baixa escolaridade, baixo peso materno prégestacional, tabagismo além do quarto mês de gestação, antecedente de cesárea, intervalo inter-partal =24 e =37 meses, antecedentes maternos de hipertensão arterial, cardiopatia e parto prematuro, poucas consultas (=5) e início tardio do pré-natal (além do 3º mês), ocorrência na gestação atual de ruptura prematura de membranas, aumento da pressão arterial, doenças infecciosas e hemorragias mostraram-se fatores de risco para BP. Primeira gravidez e obesidade materna prégestacional foram fatores protetores para BP. Recém-nascidos com BP mostraram mais sinais de comprometimento perinatal, como quantidade anormal de líquido amniótico (especialmente oligoâmnio), padrão suspeito de cardiotocografia intraparto, malformação congênita, índices de Apgar mais baixos e maior prematuridade. Também associaram-se a maior risco de indução do parto e cesárea, mas menor risco de fórcipe. Conclusões: O BP associou-se a desfechos maternos e perinatais desfavoráveis e seus determinantes na população estudada não diferiram de achados de estudos prévios. Vários dos determinantes do BP são modificáveis ou clinicamente controláveis, o que reforça a importância do aconselhamento pré-conceptual, implementação de medidas de prevenção primária e secundária no que se refere a morbidades maternas e promoção de assistência pré-natal adequada. Os resultados também reforçam a importância de maior vigilância durante o trabalho de parto nas gestações de alto risco, especialmente naquelas em que se detecta restrição de crescimento fetal ou que evoluem para trabalho de parto prematuro / Abstract: Introduction: Low birth weight (LBW) is a key issue in public health due to its short and long term consequences, especially in developing countries. Rationale: The knowledge on LBW determinants and its maternal and perinatal outcomes warrant a means of developing primary and secondary prevention policies and improving public heathcare through the promotion of a more adequate prenatal and labor care.Objectives: To identify the risk factors of LBW and the maternal and perinatal outcomes associated with its occurrence. Methods: An unmatched case-control study determined the risk factors of LBW and a retrospective cohort study determined the outcomes associated with LBW. There were analysed 43,944 deliveries that took place at CAISM between 1986 and 2004 and are recorded in an institution¿s database. All births occurring at >20 weeks whose weight ranged between 500 and 3,999g were included in the analysis. Stillbirths, twins and those cases with missing weight information were excluded. The newborns were divided into two groups: 1) LBW (<2,500g) and 2) normal birth weight (between 2,500 and 3,999g). Bivariate and multiple regression analysis determined the crude and adjusted odds ratios (OR) and risk ratios (RR) with their corresponding 95%CI for the association of LBW with its risk factors and outcomes, respectively. Results: Age, poor education, low maternal pre pregnancy weight, smoking beyond the fourth month of pregnancy, previous cesarean section, interdelivery interval =24 months and =37 months, maternal history of hypertension, cardiopathy and preterm delivery, few prenatal visits (=5) and late beginning prenatal care (after the 3rd month), premature rupture of membranes, increased blood pressure, infectious diseases and hemorrhages during current pregnancy were all associated with low birth weight. Maternal obesity and being a primigravida were found to be protective factors. LBW infants showed more often signs of perinatal compromise such as abnormal amniotic fluid (especially olygohydramnios), nonreassuring patterns of fetal heart rate, malformation, lower Apgar scores and lower gestational age at birth. They were associated with a greater risk of labor induction and cesarean delivery, but lower risk of forceps. Conclusion: There was a clear association between LBW and unfavorable maternal and neonatal outcomes. The LBW determinants in this population are mostly in accordance with the findings of previous studies. Many of the risk factors are modifiable or may be clinically controlled, which reinforces the importance of preconceptual counseling, the implementation of primary and secondary prevention of maternal morbidities and adequate prenatal care. Also worth mentioning is the importance of better labor surveillance in high risk pregnancies, especially women carrying growth restricted fetuses or presenting preterm labor / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
70

Estimativa do peso do recem-nascido por meio de medidas ultrassonograficas bidimensionais e do volume da coxa fetal / Birth weight precition by two-dimensional ultrasound measurements and fetal thigh volume

Bennini Junior, João Renato, 1978- 27 November 2018 (has links)
Orientadores: Cleisson Fabio Andrioli Peralta, Ricardo Barini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-27T11:44:05Z (GMT). No. of bitstreams: 1 BenniniJunior_JoaoRenato_M.pdf: 1809698 bytes, checksum: 399e6ab502353af527e35953428d5e09 (MD5) Previous issue date: 2009 / Resumo: Introdução: Alguns estudos demonstram que a predição do peso fetal usando a volumetria dos membros fetais é mais precisa do que quando se usam medidas bidimensionais (2D). Até hoje, somente o método multiplanar foi utilizado para a volumetria dos membros fetais. Desta forma, a utilidade do método rotacional (VOCAL®) para este fim nunca foi testada. Objetivos: Avaliar as variabilidades intra e interobservadores e a concordância entre as medidas do volume da coxa fetal realizadas com os métodos multiplanar e VOCAL®. Comparar as acurácias das fórmulas com medidas do volume da coxa fetal com as acurácias das fórmulas com medidas 2D. Comparar as acurácias das fórmulas deste estudo com as acurácias das fórmulas já publicadas. Métodos: 210 pacientes foram avaliadas, formando um grupo para gerar as fórmulas (n = 150) e um grupo para validá-las (n = 60). Os pacientes utilizados para gerar as fórmulas também foram utilizados para avaliar as variabilidades intra e interobservadores e a concordância entre as medidas realizadas pelos métodos multiplanar e VOCAL®. Foram utilizadas análises de regressão polinomial para criar uma equação com medidas 2D, uma com o volume da coxa fetal medido pelo método multiplanar (CoxaM) e uma com o volume da coxa fetal medido pelo método VOCAL® (CoxaV). Utilizaram-se testes t de Student pareados para comparar as acurácias das equações deste estudo com as acurácias das fórmulas já publicadas. Foram utilizadas análises proporcionais de Bland e Altman para avaliar as variabilidades intra e interobservadores e a concordância entre as medidas realizadas pelos métodos multiplanar e VOCAL®. Resultados: A diferença média percentual entre as medidas pelos métodos multiplanar e VOCAL® foi de -0,04 com limites de concordância de 95% de -8,17 e 8,09. A diferença média percentual e os limites de concordância de 95% entre as medidas na avaliação das variabilidades intra e interobservadores foram -1,10 (-7,67 to 5,47) e 0,61 (-7,68 to 8,91) para o método VOCAL® e 1,03 (-6,35 to 8,41) e -0,68 (-11,42 to 10,06) para o multiplanar. As melhores fórmulas para cálculo do peso fetal estimado (PFE) foram: PFE = -562.824 + 11.962 x CA x CF + 0,009 x DBP² x CA² (CA: circunferência abdominal; CF: comprimento femoral; DBP: diâmetro biparietal); PFE = 1033.286 + 12.733 x CoxaM; PFE = 1025.383 + 12.775 x CoxaV. Tanto no grupo que gerou as fórmulas como no grupo utilizado para validá-las não houve diferença significativa entre as acurácias das fórmulas com medidas 2D ou tridimensionais (3D). Quando aplicadas nas pacientes deste estudo, as acurácias das fórmulas 2D e 3D já publicadas foram significativamente piores dos que as das novas fórmulas. Conclusões: Os métodos VOCAL® e multiplanar são intercambiáveis para a volumetria da coxa fetal. Possivelmente as maiores fontes de discrepâncias na estimativa do peso fetal são as diferenças fenotípicas entre as pacientes utilizadas para criar as fórmulas. Os dados deste estudo reforçam a necessidade de fórmulas específicas para cada população, independentemente do uso de medidas 2D ou 3D. / Abstract: Introduction: Some authors have demonstrated that the prediction of birth weight using fetal limb volumetry is more precise than with two-dimensional ultrasound (2DUS). To date, only the multiplanar method has been used for fetal limb volumetry, so the usefulness of the rotational technique (VOCALTM - Virtual Organ Computer- aided AnaLysis) for this purpose has never been tested. Objectives: To evaluate the repeatability, reproducibility and agreement of measurements performed with multiplanar and VOCALTM techniques for total fetal thigh volumetry. To compare the accuracies of birth-weight-predicting models with total fetal thigh volumetry with models derived from 2DUS parameters. To compare the performances of our new formulas with those of previously published equations. Methods: 210 patients were prospectively evaluated to compose a formula-generating group (n = 150) and a prospective-validation group (n = 60). The patients of the formula-generating group were also used to evaluate the repeatability, reproducibility and the agreement of the measurements of multiplanar and VOCALTM techiniques for fetal thigh volumetry. Polynomial regression analysis was performed in the formula-generating group to generate one equation with 2DUS measurements, one with fetal thigh volume measured by the multiplanar technique (ThiM) and one with fetal thigh volume obtained by the VOCALTM method (ThiV). Paired samples t-tests were used to compare the accuracies of our equations with those of previously published 2D and three-dimensional (3D) equations. Proportionate Bland and Altman analyses were performed to determine the agreement between the two methods and to evaluate intra- and inter-observer variability. Results: The mean percentage difference between measurements performed with the VOCALTM and multiplanar techniques was -0.04 and the 95% limits of agreement were -8.17 and 8.09. The mean percentage difference and 95% limits of agreement between paired measurements in the assessment of intra- and inter-observer variability were -1.10 (-7.67 to 5.47) and 0.61 (-7.68 to 8.91) for the VOCALTM technique and 1.03 (-6.35 to 8.41) and -0.68 (-11.42 to 10.06) for the multiplanar method. The formulas with the best fit for the prediction of birth weight (EFW) were: EFW = -562.824 + 11.962 x AC x FL + 0.009 x BPD² x AC² (AC: abdominal circumference; FL: femur length; BPD: biparietal diameter); EFW = 1033.286 + 12.733 x ThiM; EFW = 1025.383 + 12.775 x ThiV. For both the formula-generating and the rospective-validation groups, there was no significant difference between the accuracies of the new 2DUS and 3DUS models. When applied to our population, the accuracies of previously published 2DUS and 3DUS formulas were significantly worse than our models. Conclusions: The VOCALTM and multiplanar techniques can be used interchangeably for total fetal thigh volumetry. We believe that the greatest sources of discrepancies in estimation of birth weight are the phenotypic differences among patients used to create each of the formulas mentioned in this study. Our data reinforce the need for customized birth weight prediction formulas, regardless of whether 2DUS or 3DUS measurements are employed. / Mestrado / Tocoginecologia / Mestre em Tocoginecologia

Page generated in 0.1338 seconds