• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 51
  • 11
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 159
  • 159
  • 139
  • 68
  • 63
  • 62
  • 59
  • 56
  • 25
  • 21
  • 19
  • 19
  • 17
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Desenvolvimento de procedimentos analíticos limpos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de cobalto e cádmio em águas / Development of clean analytical procedures employing multicommutation flow analysis systems for photometric determination of cobalt and cadmium in waters

Ticiane Silva Gondim 12 December 2016 (has links)
Esse trabalho tem como objetivo o desenvolvimento de procedimentos analíticos automáticos, empregando o processo de multicomutação em fluxo para determinação espectrofotométrica de cobalto e cádmio em amostras de águas. O trabalho envolveu o desenvolvimento dos módulos de análises para implementar os procedimentos analíticos baseados no processo de multicomutação, o sistema de detecção fotométrica empregando LED como fonte de radiação eletromagnética, o software para controle do módulo de análise e para efetuar aquisição de dados. O módulo de análise para determinação de cobalto foi desenvolvido, utilizando mini-bombas solenóide para o bombeamento das soluções. O procedimento analítico foi baseado na catálise do cobalto na reação de oxidação do Tiron pelo peróxido de hidrogênio e com o sistema de detecção espectrofotométrica com LED com emissão em 425 nm. Após os ajustes necessários do módulo de análise o sistema apresentou bom desempenho analítico. Para a determinação de cobalto em águas foram obtidas as seguintes características analíticas: desvio padrão relativo de 0,04 % (n = 13) para uma amostra com 0,5 µgL-1 de Co, faixa de resposta linear entre 0,13 a 1,5 µgL-1 de Co (R = 0,998, n = 3), limite de detecção de 0,06 µgL-1, frequência analítica de 42 determinações por hora e geração de 1,5 mL de resíduo por determinação. Recuperações entre 84 e 114 % foram obtidas com adição de Co (II) nas amostras de águas. O módulo de análise para determinação cádmio foi desenvolvido e otimizado utilizando duas mini-bombas peristálticas para bombeamento das soluções e esvaziamento do percurso, uma válvula solenoide de três vias e três válvulas solenoide de duas vias, uma cela de fluxo com longo caminho óptico (100 mm) e LED com emissão em 520 nm. O procedimento analítico para a determinação do cádmio foi baseado na formação do complexo pelo Cd (II) com o reagente ditizona em meio micelar com o surfactante Triton X100. O procedimento apresentou faixa de resposta linear de 15,0 a 175,0 µgL-1 de Cd (R = 0,997; n = 3), limite de detecção de 12,5 µgL-1, desvio padrão relativo de 0,57 % (n = 10) para uma amostra de 30 µgL-1 e frequência analítica de 43 amostras por hora. Recuperações entre 84 e 112 % foram obtidas com adição de Cd (II) nas amostras de águas. / This work deals with the development of automatic analytical procedures, based on multicommuted flow analysis process for spectrophotometric determination of cobalt and cadmium in water samples. The work involved the development of the analytical modules and the photometric detector using LEDs as electromagnetic radiation sources. The software to control the flow analysis module and to perform data acquisition, were developed using Quick BASIC4.5 as programming language. The analysis module for cobalt determination, employed solenoid mini-pumps for solutions pumping. The procedure was based on the cobalt catalytic effect on the Tiron oxidation by hydrogen peroxide and the photometric detection at 425 nm. After the necessary adjustments of the flow analysis module, the system showed good analytical performance. The following analytical characteristics for determination of cobalt in water were obtained: a relative standard deviation of 0.04% (n = 13) for a standard solution 0.5 µgL-1 Co, a linear response ranging from 0.13 to 1.5 µgL-1 Co (R = 0.998, n = 3), a detection limit of 0.06 µgL-1, analytical frequency of 42 samples determination per hour and a waste generation of 1.5 mL per determination. Recoveries between 84 and 114% were obtained with the addition of Co (II) in water samples. The analytical module for determination of cadmium was developed, using two peristaltic mini-pumps and solenoid valves. The LED based photometer was furnished with a flow cell of long optical path (100 mm) and a LED with maximum emission at 520 nm. The flow analysis module was assembled with ability to perform a closed loop strategy, which was implemented to improve sensitivity. The analytical procedure for the determination of cadmium was based on reaction of Cd (II) with dithizone in a micelle medium with the surfactant Triton X-100. The procedure showed a linear response ranging from 15.0 to 175.0 µgL-1 Cd (R = 0.997; n = 3), detection limit of 12.5 µgL-1, RSD 0.57% (n = 10) for a sample of 30 µgL-1 and analytical frequency of 43 samples per hour. Recoveries between 84 and 112% were obtained with addition of Cd (II) in water samples.
112

Determinação espectrofotométrica catalítica de molibdênio e ferro explorando calibração multivariada em um sistema de análises químicas em fluxo / Catalytic spectrophotometric determination of Mo(VI) and Fe(III) exploiting multivariate calibration implemented in a flow system

Eliézer de Oliveira 30 November 2015 (has links)
Os efeitos catalíticos de Mo(VI) e Fe(III) na oxidação de iodeto por peróxido de hidrogênio foram explorados visando à determinação simultânea destes. Diferenças nas taxas de reação foram alcançadas através do estabelecimento de duas zonas reacionais distintas para alteração das cinéticas reacionais. Para isto, foi projetado um sistema de análises por injeção em fluxo que permite a inserção de duas alíquotas de amostra, sendo adicionado ácido sulfúrico em uma destas com formação de uma zona de amostra complexa. Cada elemento de fluido desta zona é caracterizado por composição química, tempo de residência e taxa de reação específicas. Os principais parâmetros que afetam a taxa reacional, tais como concentração dos reagentes, comprimento do reator e vazão total, dentre outros, foram avaliados buscando melhoria na sensibilidade e discriminação cinética entre os analitos. Os comprimentos das alças de amostragem e da bobina separadora foram avaliados construindo-se modelos matemáticos visando máxima discriminação nas previsões para os analitos. Os modelos foram construídos a partir da ferramenta quimiométrica PLS (Partial Least Squares) utilizando os dados gerados por medidas de máximos e mínimos ao longo da zona de amostra. O conjunto de calibração era composto por misturas de Mo(VI) e Fe(III) na faixa de concentrações 6,2 - 50,0 ?g L-1 e 0,5 - 7,0 mg L-1, respectivamente. O modelo selecionado apresenta boa habilidade de previsão com valores de RMSEP estimados como 0,67 ?g L-1 para Mo(VI) e 0,21 mg L-1 para Fe(III). Recuperações entre 85 e 114% foram obtidas para amostras de águas naturais. O sistema proposto apresenta estabilidade física, boa repetibilidade entre as leituras (d. p. r. < 2 %), velocidade analítica de 31 h-1 e consumo de 54 mg de iodeto de potássio e 0,30 mg de peróxido de hidrogênio por amostra / The catalytic effects of Mo(VI) and Fe(III) in the oxidation of iodide by hydrogen peroxide were exploited aiming at their simultaneous determination. Differences in reaction rates were achieved by establishing of two distinct reactions zones to modify the reaction kinetics involved. To this end, a flow injection system allowing insertion of two sample aliquots was designed, and sulfuric acid was added to one of the aliquots. A complex sample zone was then established. Each fluid element of this zone was characterized by a given chemical composition, residence time and reaction rate. The main parameters affecting the reaction rate, such as reagent concentrations, analytical path length and total flow rate, among others, were evaluated for improving sensitivity and analyte kinetic discrimination. Influences of sampling loop lengths and distance between initial plugs were studied, and mathematical models were constructed aiming at improved discrimination in prediction of analytes. The models were constructed from the PLS (Partial Least Squares) chemometric tool using data generated by measurements performed on sample zone regions with maximum and minimum local concentrations. The calibration set consisted of Mo(VI) and Fe(III) mixtures in concentration ranges of 6.2 - 50.0 ?g L-1 and 0.5 - 7.0 mg L-1, respectively. The selected model is characterized by good prediction ability prediction, as RMSEP values were estimated as 0.67 ?g L-1 for Mo(VI) and 0.21 mg L-1 for Fe(III), respectively. Recoveries within the 85 - 114% range were obtained for natural waters. The proposed system presents physical stability and favorable characteristics of measurement repeatability (r.s.d.<2%), sampling rate (31 h-1) and reagent consumption (54 mg of KI and 0.30 mg H2O2 per sample)
113

Desenvolvimento de instrumentação e procedimentos automáticos para determinação de arsênio e fluoreto em águas empregando multicomutação em fluxo e detecção fotométrica / Development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutaion and photometric detection

Marcelo Alves Teixeira 12 May 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de fluoreto e arsênio em águas empregando o conceito de multicomutação em fluxo e detecção fotométrica. Na determinação de fluoreto, o controle dos dispositivos foi realizado empregando um computador, programado em QuickBasic 4.5. O fotômetro desenvolvido utilizava um fotodetector (OPT301), uma cela de fluxo com 60 mm de caminho óptico e um LED (\'lambda\' = 525 nm), usado como fonte de radiação. Os sinais gerados pelo fotômetro foram convertidos para digital empregando um multímetro digital, que os transferia para o computador através da interface serial RS-232. O procedimento para a determinação de fluoreto foi baseado no método de zircônio/ vermelho de alizarina S, onde o fluoreto retira o zircônio da estrutura metal ligante formando um complexo incolor. Após a seleção das variáveis de controle, o procedimento proposto apresentou resposta linear na faixa de 0,25 a 1,75 mg L-1 (LD = 0,06 mg L-1), desvio relativo menor que 3,5%, freqüência de amostragem de 45 h-1. No sistema para determinação de arsênio em águas, o controle do módulo de análise foi realizado utilizando um microcontrolador da série PIC 18F2553, o qual contém um conversor A/D interno de 12 bits de resolução e capacidade de operar com taxa de amostragem de até 100.000 s-1. O mesmo recebia os parâmetros de controle por um computador via USB 2.0, que utilizava a mesma interface para transferir os dados provenientes do fotômetro. O software para essa comunicação foi escrito em Delphi 7.0 e a linguagem C foi utilizada para a programação do microcontrolador. Como sistema de detecção foi o mesmo empregado na determinação de fluoreto, utilizando um LED (\'lambda\' = 625 nm) como fonte de radiação. O procedimento proposto para a determinação de arsênio foi baseado na reação do arsênio inorgânico com boro-hidreto, onde a arsina formada reagia com azul de metileno em meio micelar. A descoloração da solução de azul de metileno era proporcional à concentração de arsênio presente na amostra. A procedimento proposto apresentou resposta linear na faixa de 2,5 a 40 \'mü\'g L-1 (r = -0,995), limite de detecção de 0,3 \'mü\'g L-1, desvio relativo menor que 6,5 %, freqüência de amostragem de 25 h-1. / The development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutation and photometric detection were proposed. For fluoride determination, the system was controlled by a microcomputer equipped with MS-Dos environment and running a software written in Quick Basic 4.5. It was used a homemade photometric detector OPT301, a 60 mm pathway flow cell, and a light emitting diode (\'lambda\' = 525 nm) as light source. Data acquisition was performed by using a digital multimeter and a microcomputer with RS- 232 serial interface. The method was based on a complexation reaction between fluoride and alizarin red S, where the fluoride takes out the zircon from the metal-binding moieties resulting in color bleaching. After optimization of parameters, the procedure provided linear response in the 0.25 to 1.75 mg L-1 range, limit of detection of 0.06 mg L- 1, coefficient of variation lower than 3.5 %, and sample throughput of 45 determinations per hour. For arsenic determination, the control module was performed by using a PIC 18F2553 microcontroller equipped with a 12 bits resolving power A/D internal converter, working at 100,000 sampling per second rate. Data acquisition was performed by a microcomputer equipped with Windows environment and running a software written in Delphi 7.0. A LED (\'lambda\' = 625 nm), as radiation source, was used for As determinations by using the same detection system used for fluoride determination. The method for As determination was based on the color bleaching of methylene blue in micellar media by AsH3 produced from inorganic As and NaBH4. The color bleaching of methylene blue was proportional to As concentration in the sample. The proposed method provided linear response in the 2.5 to 40 \'mü\'g L-1 range, limit of detection of 0,3 \'mü\'g L-1, coefficient of variation lower than 6.5 %, and sample throughput of 25 determinations per hour.
114

Desenvolvimento de uma câmara flow-batch com aquecimento direto e de procedimentos analíticos para determinação fotométrica de açúcares redutores em vinhos e de manganês em amostras vegetais / Development of a flow- batch chamber with direct heating and analytical procedures for photometric determination of reducing sugars in wine and manganese in plant samples

Marcos Augusto Stolf Brasil 27 July 2016 (has links)
Neste trabalho foi desenvolvido um sistema analítico tendo como elemento central uma câmara flow-batch com aquecimento direto e fotômetro acoplado, empregado para determinação de açúcares redutores em vinhos e de manganês em amostras vegetais. A instrumentação foi implementada utilizando o conceito flow-batch e o processo de multicomutação em fluxo. A proposta da câmara com aquecimento direto foi concebida para viabilizar procedimentos analíticos baseados em reações lentas. Adicionalmente, foi realizada a instalação do sistema de detecção fotométrica no próprio corpo da câmara, eliminando a necessidade de resfriamento e transporte da solução para outro componente para monitoramento. Esta estratégia possibilitou a redução das dimensões do sistema e o incremento na frequência de amostragem. O controle do sistema é realizado usando aplicativo desenvolvido na linguagem Visual Basic®, o qual aciona seus componentes e realiza a leitura do sinal analítico através de uma interface. Para propulsão dos fluidos é utilizada uma bomba peristáltica multicanal, ambos dispositivos foram desenvolvidos dentro do presente trabalho. Para a determinação de açúcares redutores em vinho, o método analítico adotado utiliza como reagente cromogênico o hexacianoferrato (III) de potássio em meio alcalino sob aquecimento (50 oC) e leitura em 420 nm. O sistema apresentou uma faixa de resposta linear entre 0,75 e 6% (m/v) frutose (R2= 0,999), limite de detecção de 0,14% (m/v; n = 11), desvio padrão relativo menor que 4%, e frequência analítica de 75 determinações por hora. O procedimento para a determinação de manganês foi baseado na reação de oxidação à permanganato, utilizando como agente oxidante periodato de sódio em meio ácido, aquecimento a 55 oC, e leitura em 530 nm. Após estabelecer as variáveis de controle, o sistema apresentou faixa de resposta linear entre 5 e 30 mg.L-1(R² = 0,997), limite de detecção de 2 mgL-1 (n = 11) Mn2+, desvio padrão relativo de 5%, e frequência analítica de 40 determinações por hora. A exatidão dos resultados foi avaliada aplicando o teste t-Student, onde foram comparados os resultados obtidos com os procedimentos propostos com aqueles obtidos com métodos de referência, e não foram observadas diferenças significativas ao nível de confiança de 95 % / In this work was developed an analytical system, employing a flow-batch chamber with direct heating coupled to a LED based photometer, which was tailored for the determination of reducing sugars in wine and manganese in plant samples. The instrumentation was implemented using the flow-batch concept and multicommutation flow analysis process. The proposed camera with direct heating was designed to enable analytical procedures based on slow reactions. The photometer coupling to the flow-batch chamber body, eliminated the need for a cooling step and as well as solution transportation for another component, where signal would be monitored. This strategy allowed the reduction of the system dimensions, and enabling an increase in sampling frequency. The system control was performed using software developed in Visual Basic ® language, which drove the actives components of the system. For fluid propulsion was used a multichannel peristaltic pump, which was also developed in the present work. For the determination of reducing sugars in wine, the analytical procedure was based on the reaction of potassium hexacyanoferrate (III) in an alkaline medium under heating at 50 ° C, which was monitored at 420 nm. The procedure provided a linear response ranging from 0.75 to 6.00 % (w / v) fructose (R2 = 0.999), a 0.14% limit of detection (w/v, n = 11), a relative standard deviation less than 4.0 %, and an analytical frequency of 75 determination per hour. The procedure for the determination of manganese was based on the permanganate oxidation reaction in acid medium, using sodium periodate solution as an oxidizing reagent. The flow-batch was maintained at 55 ° C, and signal was monitored at 530 nm. After establishing the control variables, the procedure provided a linear response ranging from 5.0 to 30.0 mg L-1 (R2 = 0.997), a detection of limit 2.0 mg L-1 (n = 11) Mn2+, a relative standard deviation of 5.0 % (n = 8) and an analytical frequency of 40 determination per hour. The accuracy of the results was assessed by applying the Student t-test between results obtained employing the proposed procedures and a reference method, and not significant difference at 95 % confidence level was observed
115

Desenvolvimento de sistemas de análises em fluxo por multicomutação para determinação de poluentes ambientais / Development of systems of flow injection analysis with commutation for determination of environmental pollutants

Carlos Martín Infante Córdova 23 September 2008 (has links)
O presente trabalho teve como objetivo o desenvolvimento de procedimentos analíticos baseados na análise em fluxo com multicomutação, acoplada à detecção por fluorescência, espectrofotometria com longo caminho óptico ou quimiluminescência em guias de ondas (LCW), para a determinação de poluentes ambientais. Os procedimentos desenvolvidos atendem aos requisitos de sensibilidade e limite de detecção impostos pela legislação ambiental vigente e as características analíticas encontram-se em concordância com as tendências atuais de redução do consumo de amostras e reagentes, da geração de resíduos e de custo, apresentando alta freqüência de amostragem e operação simples. Os módulos de análises desenvolvidos são compactos, podendo ser adaptados para o monitoramento in situ. Com o acoplamento da cela LCW de 100 cm de caminho óptico a sistemas de análises por injeção em fluxo e monossegmentado, para medidas por turbidimetria e espectrofotometria, foi observada significativa melhora nos limites de detecção e sensibilidade. Discrepâncias entre o aumento de sensibilidade verificado e previsto pela lei de Beer têm relação com diferenças de dispersão em celas de 1 e 100 cm. Para a determinação espectrofotométrica de paraquat, foi desenvolvido um módulo de análises com micro-bombas solenóides. Ácido dehidroascórbico foi empregado como reagente, sendo a solução estável por uma semana. Resposta linear foi observada de 0,1 a 5,0 mg L1, r=0,997, com limite de detecção, coeficiente de variação e freqüência de amostragem estimados em 22 &#181;g L-1, 1,0% (n=10) e 63 h-1, respectivamente. Os resultados para amostras de águas foram concordantes com o procedimento de referência (95% de confiança). Para a determinação fluorimétrica de cianeto dissociável em ácidos, foi desenvolvido um módulo de análises com válvulas solenóides, explorando a reação com oftalaldeído e glicina. Sensibilidade 2 vezes maior foi observada com a retenção da zona de amostra por 60 s, com resposta linear entre 1 e 200 &#181;g L-1, r=0,999. O coeficiente de variação, limite de detecção e freqüência de amostragem foram estimados em 1,4% (n=10), 0,5 &#181;g L-1 e 22 h-1, respectivamente. Com prévia etapa de separação por difusão gasosa, o procedimento foi aplicado em amostras de águas naturais, sendo os resultados concordantes com o procedimento de referência ao nível de confiança de 95%. Para a especiação redox de cromo, os procedimentos analíticos foram baseados em sistemas de análises em fluxo com micro-bombas solenóides. O Cr(VI) foi determinado por espectrofotometria de longo caminho óptico com difenilcarbazida. Resposta linear foi observada entre 2 e 40 g L-1, r=0,973. O limite de detecção, coeficiente de variação e freqüência de amostragem foram estimados em 1,8 &#181;g L-1, 0,6% (n=10) e 55 h-1, respectivamente. Quimiluminescência foi utilizada para determinar Cr(III), com resposta linear observada entre 2 e 50 &#181;g L-1, com r=0,999. O limite de detecção, coeficiente de iv variação e freqüência de amostragem foram estimados em 0,38 &#181;g L-1, 3,3% (n=10) e 50 h-1, respectivamente. Oxidação em linha foi também implementada para a determinação espectrofotométrica de cromo total. Em amostras de águas naturais, os resultados foram concordantes para Cr(VI), mas efeitos de matriz foram observados para Cr(III), aparentemente devido à complexação com sustâncias húmicas. / This work aimed the development of analytical procedures based on flow analysis with multicommutation, coupled to detection by fluorescence, long pathlength spectrophotometry or chemiluminescence in liquid-core waveguides (LCW), for determination of environmental pollutants. The developed procedures are in accordance with the requirements of sensitivity and detection limits of the current environmental legislation and the analytical characteristics are in agreement with current trends as low sample and reagents consumption, low waste generation, high sampling rate, low cost and simple operation. The compact flow systems could be adapted for in situ monitoring. Improvements in detection limit and sensitivity were observed by coupling the 100-cm LCW to flow injection analysis and monosegmented flow analysis for turbidimetric and spectrophotometric measurements. Discrepancies between the experimentally evaluated increase in sensitivity and that estimated by the Beers law are related to differences in sample dispersion with 1 and 100 cm flow cells. A multicommuted flow-system with solenoid micro-pumps was used for the spectrophotometric determination of paraquat. The reducing reagent, dehydroascorbic acid, was stable for at least one week. Linear response was observed from 0.1 to 5.0 mg L-1, with r=0.997 and detection limit, coefficient of variation and sampling rate estimated as 22 &#181;g L-1, 1.0% (n=10) and 63 h-1, respectively. The procedure was applied for paraquat determination in water samples, yielding results in agreement with the reference procedure at the 95% confidence level. For the fluorimetric determination of Weak Acid Dissociable Cyanide, a multicommuted flow system was development with solenoid valves, exploiting the reaction with o-phthalaldehyde and glycine. A two-fold higher sensitivity was observed with a 60-s stopped-flow interval, with linear response between 1 and 200 &#181;g L-1, r=0.999. The coefficient of variation, detection limit and sampling rate were estimated as 1.4% (n=10), 0.5 &#181;g L-1 and 22 h-1, respectively. After separation by gas diffusion, the procedure was applied to the analysis of natural water samples, with results in agreement with the reference procedure at the 95% confidence level. For redox chromium speciation, the procedures were based on a multicommuted flow system with solenoid micro-pumps. The determination of Cr(VI) was performed by long pathlength spectrophotometrywith diphenylcarbazide. Linear response was observed between 2 and 40 g L-1, r=0.973. The detection limit, coefficient of variation and sampling rate were estimated as 1.7 g L-1, 0.6% (n=10) and 55 h-1, respectively. Chemiluminescence was used to determine Cr(III), being the linear response observed between 2 and 50 &#181;g L-1, with r=0.999. The detection limit, coefficient of variation and sampling rate were estimated as 0.38 &#181;g L-1, 3.3% (n=10) and 50 h-1, respectively. On-line oxidation was also implemented for the determination of total chromium. In natural water samples, results were consistent for Cr(VI), but matrix vi effects were observed in Cr(III) determination, apparently in view of complexation with humic substances.
116

Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína / Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine

Oliveira, Laura Siqueira de 17 January 2012 (has links)
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense. / The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.
117

Desenvolvimento de sistemas de análises em fluxo por multicomutação para determinação de poluentes ambientais / Development of systems of flow injection analysis with commutation for determination of environmental pollutants

Córdova, Carlos Martín Infante 23 September 2008 (has links)
O presente trabalho teve como objetivo o desenvolvimento de procedimentos analíticos baseados na análise em fluxo com multicomutação, acoplada à detecção por fluorescência, espectrofotometria com longo caminho óptico ou quimiluminescência em guias de ondas (LCW), para a determinação de poluentes ambientais. Os procedimentos desenvolvidos atendem aos requisitos de sensibilidade e limite de detecção impostos pela legislação ambiental vigente e as características analíticas encontram-se em concordância com as tendências atuais de redução do consumo de amostras e reagentes, da geração de resíduos e de custo, apresentando alta freqüência de amostragem e operação simples. Os módulos de análises desenvolvidos são compactos, podendo ser adaptados para o monitoramento in situ. Com o acoplamento da cela LCW de 100 cm de caminho óptico a sistemas de análises por injeção em fluxo e monossegmentado, para medidas por turbidimetria e espectrofotometria, foi observada significativa melhora nos limites de detecção e sensibilidade. Discrepâncias entre o aumento de sensibilidade verificado e previsto pela lei de Beer têm relação com diferenças de dispersão em celas de 1 e 100 cm. Para a determinação espectrofotométrica de paraquat, foi desenvolvido um módulo de análises com micro-bombas solenóides. Ácido dehidroascórbico foi empregado como reagente, sendo a solução estável por uma semana. Resposta linear foi observada de 0,1 a 5,0 mg L1, r=0,997, com limite de detecção, coeficiente de variação e freqüência de amostragem estimados em 22 &#181;g L-1, 1,0% (n=10) e 63 h-1, respectivamente. Os resultados para amostras de águas foram concordantes com o procedimento de referência (95% de confiança). Para a determinação fluorimétrica de cianeto dissociável em ácidos, foi desenvolvido um módulo de análises com válvulas solenóides, explorando a reação com oftalaldeído e glicina. Sensibilidade 2 vezes maior foi observada com a retenção da zona de amostra por 60 s, com resposta linear entre 1 e 200 &#181;g L-1, r=0,999. O coeficiente de variação, limite de detecção e freqüência de amostragem foram estimados em 1,4% (n=10), 0,5 &#181;g L-1 e 22 h-1, respectivamente. Com prévia etapa de separação por difusão gasosa, o procedimento foi aplicado em amostras de águas naturais, sendo os resultados concordantes com o procedimento de referência ao nível de confiança de 95%. Para a especiação redox de cromo, os procedimentos analíticos foram baseados em sistemas de análises em fluxo com micro-bombas solenóides. O Cr(VI) foi determinado por espectrofotometria de longo caminho óptico com difenilcarbazida. Resposta linear foi observada entre 2 e 40 g L-1, r=0,973. O limite de detecção, coeficiente de variação e freqüência de amostragem foram estimados em 1,8 &#181;g L-1, 0,6% (n=10) e 55 h-1, respectivamente. Quimiluminescência foi utilizada para determinar Cr(III), com resposta linear observada entre 2 e 50 &#181;g L-1, com r=0,999. O limite de detecção, coeficiente de iv variação e freqüência de amostragem foram estimados em 0,38 &#181;g L-1, 3,3% (n=10) e 50 h-1, respectivamente. Oxidação em linha foi também implementada para a determinação espectrofotométrica de cromo total. Em amostras de águas naturais, os resultados foram concordantes para Cr(VI), mas efeitos de matriz foram observados para Cr(III), aparentemente devido à complexação com sustâncias húmicas. / This work aimed the development of analytical procedures based on flow analysis with multicommutation, coupled to detection by fluorescence, long pathlength spectrophotometry or chemiluminescence in liquid-core waveguides (LCW), for determination of environmental pollutants. The developed procedures are in accordance with the requirements of sensitivity and detection limits of the current environmental legislation and the analytical characteristics are in agreement with current trends as low sample and reagents consumption, low waste generation, high sampling rate, low cost and simple operation. The compact flow systems could be adapted for in situ monitoring. Improvements in detection limit and sensitivity were observed by coupling the 100-cm LCW to flow injection analysis and monosegmented flow analysis for turbidimetric and spectrophotometric measurements. Discrepancies between the experimentally evaluated increase in sensitivity and that estimated by the Beers law are related to differences in sample dispersion with 1 and 100 cm flow cells. A multicommuted flow-system with solenoid micro-pumps was used for the spectrophotometric determination of paraquat. The reducing reagent, dehydroascorbic acid, was stable for at least one week. Linear response was observed from 0.1 to 5.0 mg L-1, with r=0.997 and detection limit, coefficient of variation and sampling rate estimated as 22 &#181;g L-1, 1.0% (n=10) and 63 h-1, respectively. The procedure was applied for paraquat determination in water samples, yielding results in agreement with the reference procedure at the 95% confidence level. For the fluorimetric determination of Weak Acid Dissociable Cyanide, a multicommuted flow system was development with solenoid valves, exploiting the reaction with o-phthalaldehyde and glycine. A two-fold higher sensitivity was observed with a 60-s stopped-flow interval, with linear response between 1 and 200 &#181;g L-1, r=0.999. The coefficient of variation, detection limit and sampling rate were estimated as 1.4% (n=10), 0.5 &#181;g L-1 and 22 h-1, respectively. After separation by gas diffusion, the procedure was applied to the analysis of natural water samples, with results in agreement with the reference procedure at the 95% confidence level. For redox chromium speciation, the procedures were based on a multicommuted flow system with solenoid micro-pumps. The determination of Cr(VI) was performed by long pathlength spectrophotometrywith diphenylcarbazide. Linear response was observed between 2 and 40 g L-1, r=0.973. The detection limit, coefficient of variation and sampling rate were estimated as 1.7 g L-1, 0.6% (n=10) and 55 h-1, respectively. Chemiluminescence was used to determine Cr(III), being the linear response observed between 2 and 50 &#181;g L-1, with r=0.999. The detection limit, coefficient of variation and sampling rate were estimated as 0.38 &#181;g L-1, 3.3% (n=10) and 50 h-1, respectively. On-line oxidation was also implemented for the determination of total chromium. In natural water samples, results were consistent for Cr(VI), but matrix vi effects were observed in Cr(III) determination, apparently in view of complexation with humic substances.
118

Immobilisation d'enzymes pour la réalisation de biocapteurs : Analyse par injection en flux continu (FIA) : Applications au dosage des composes polluants

Kumaran, Satish 02 December 1991 (has links) (PDF)
Cette étude porte sur la réalisation de biocapteurs et la mise au point d'un système d'analyse par injection en flux continu (FIA). Ces systèmes sont destinés au dosage de composés polluants présents dans l'eau, notamment de pesticides organophosphorés et de carbamates. Ces biocapteurs associent une électrode de pH et une membrane enzymatique. Différentes techniques d'immobilisation des cholinestérases (acétylcholinestérase et butyrylcholinestérase) sur des membranes polyamide pré-activées, par piégeage dans un gel polymère et sur des membranes en toile de Nylon™ sont d'abord présentées. Ensuite, l'optimisation des conditions opératoires et la comparaison de leurs performances sont examinées. Des capteurs enzymatiques à réponse rapide, pour le dosage de substrat, sont réalisés grâce à une nouvelle technique d'immobilisation d'enzyme sur électrode de verre (Brevet français F-9011630, 1990). L'innovation de cette technique réside dans le dépôt par vaporisation d'un agent réticulant sur l'extrémité sensible de l'électrode de verre. Une simulation mathématique de la réponse de ces biocapteurs permet d'apprécier les quantités d'enzyme immobilisées. Un système FIA basé sur l'inhibition de l'acétylcholinestérase immobilisée au sein d'un réacteur tubulaire à une rangée de billes, est mis au point pour le dosage des organophosphates et des carbamates. Plusieurs paramètres opératoires sont d'abord optimisés. Ce système est ensuite appliqué au dosage d'insecticides contaminant accidentellement l'eau de mer. La réactivation, dans le réacteur, de l'enzyme inhibée permet sa réutilisation de nombreuses fois.
119

Determina??o de Verapamil e Oxcarbazepina em amostras de urina e formula??es farmac?uticas por amperometria pulsada em FIA

Lima, Amanda Barbosa January 2016 (has links)
Data de aprova??o ausente. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2017-03-24T17:42:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-04-20T19:16:33Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) / Made available in DSpace on 2017-04-20T19:16:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) Previous issue date: 2016 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Verapamil (VP) e Oxcarbazepina (OX) s?o f?rmacos de baixo ?ndice terap?utico que necessitam de rigoroso controle de qualidade em formula??es farmac?uticas, bem como de an?lises em fluidos biol?gicos para estudos farmacol?gicos de elimina??o dessas drogas. Neste sentido, o desenvolvimento de m?todos simples, r?pidos e de baixo custo ? de extrema import?ncia para quantifica??o desses f?rmacos nessas amostras. Deste modo, o presente trabalho apresenta um m?todo eletroanal?tico em fluxo para determinar VP e OX tanto em formula??es farmac?uticas, quanto em amostras de urina. A t?cnica eletroqu?mica utilizada para quantifica??o foi a Amperometria de M?ltiplos Pulsos (MPA) acoplada a um sistema de an?lise por inje??o em fluxo (FIA), utilizando o diamante dopado com boro (BDD). Foram aplicados tr?s pulsos de potencial pela MPA para determina??o do VP em meio de ?cido sulf?rico 0,1 mol L-1, sendo +1,6 V para a oxida??o e, posteriormente, +0,2 V para redu??o do produto gerado do VP e +0,1 V para a limpeza do eletrodo de BDD. Para a determina??o de OX, tamb?m foram otimizados tr?s pulsos de potencial em meio de tamp?o acetato 0,1 mol L-1 (pH 4,0), sendo + 1,7 V para a oxida??o da OX e gera??o do produto que foi reduzido em -1,1 V e -1,3 V para a limpeza do eletrodo de BDD. Em ambos os casos, apenas o sinal obtido nos pulsos de potencial de redu??o foram utilizados para quantifica??o dos f?rmacos. As faixas lineares de trabalho obtidas para quantifica??o do VP e da OX foram de 0,8 a 40,0 ?mol L-1 (R= 0,9976) e 2,0 a 80,0 ?mol L-1 (R= 0,9989), respectivamente. Os limites de detec??o foram calculados em 0,16 ?mol L-1 para VP e 0,42 ?mol L-1 para OX. Uma boa repetibilidade foi obtida para 10 an?lises consecutivas desses f?rmacos, com desvio padr?o relativo de 2,2% para VP e 0,94 % para OX. Os estudos de adi??o e recupera??o do VP e OX em amostras farmac?uticas e urina apresentaram resultados pr?ximos a 100% e o doseamento do VP foi validado pela metodologia oficial. Altas frequ?ncias anal?ticas foram alcan?adas pelo sistema FIA com 45 e 65 determina??es por hora de VP e OX, respectivamente, usando al?as de amostragem inferiores a 200 ?L e vaz?es de 3,5 mLmin-1. An?lises desses f?rmacos em amostras de urina mostraram que ? poss?vel determin?-los mesmo na presen?a de altas concentra??es de ?cido asc?rbico e ?cido ?rico. Portanto, o m?todo proposto mostrou-se como alternativa simples e r?pida para quantifica??o desses f?rmacos em formula??es farmac?uticas e urina. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, [2016]. / Verapamil (VP) and Oxcarbazepine (OX) are drugs of narrow therapeutic index that require strict quality control in pharmaceutical formulations and analysis in biological fluids for pharmacological studies of elimination of these drugs. In this sense, the development of simple, fast and low-cost methods is very important to quantify these drugs in pharmaceutical samples. Therefore, this work presents a electroanalytical method in flow for determining VP and OX in pharmaceutical formulations and human urine samples. The electrochemical technique used for quantification was performed by multiple pulses amperometry (MPA) coupled to a flow injection analysis system (FIA), using boron-doped diamond (BDD) as working electrode. Were applied three potential pulses by MPA for the determination of VP in sulfuric acid 0.1 mol L-1: (1) +1.6 V for oxidation of VP, (2) +0.2 V for reduction of the generated product of VP in the fisrt potential pulse, (3) +0.1 V for cleaning of the BDD electrode surface. The determination of OX also was performed by MPA in three potential pulses in 0.1 mol L-1 acetate buffer (pH 4.0): (1) +1.7 V for oxidation of OX and generation of the product that it was reduced at (2) -1.1 V, and (3) -1.3 V for cleaning of the BDD electrode surface. In both cases, only the signal obtained in the reduction potential pulses were used for quantification of drugs. The linear ranges of work obtained for quantitation of VP and OX were 0.8 to 40.0 ?mol L-1 (R = 0.9976) and 2.0 to 80.0 ?mol L-1 (R = 0, 9989), respectively. The detection limits were calculated to be 0.16 ?mol L-1 for VP and 0.42 ?mol L-1 for OX. Good repeatabilities were obtained for 10 consecutives injections of these drugs, with relative standard deviation of 2.2% for VP and 0.94% for OX. The addition and recovery studies for VP and OX in pharmaceutical and urine samples were close to 100% and determination of VP was validated by the official methodology. High analytical frequencies were achieved by FIA system of 45 and 65 determinations per hour for VP and OX, respectively, using sampling handles less than 200 ?L and flow rate of 3.5 mLmin-1. The analysis of these drugs in urine showed that it is possible to determine this sample even in the presence of high concentrations of ascorbic acid and uric acid. Therefore, the present method by MPA-FIA proved to be a quick and easy alternative to quantify VP and OX in pharmaceutical formulations and urine.
120

Studies of a microporous membrane for analyte preconcentration and separation

Jacob, Silvana do Couto January 1994 (has links)
Submitted by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2016-05-11T13:46:20Z No. of bitstreams: 1 Thesis-1994-Jacob.pdf: 26119019 bytes, checksum: b8e19fd69a5cb720e5071df7ae1b03bb (MD5) / Approved for entry into archive by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2016-05-11T14:21:12Z (GMT) No. of bitstreams: 1 Thesis-1994-Jacob.pdf: 26119019 bytes, checksum: b8e19fd69a5cb720e5071df7ae1b03bb (MD5) / Made available in DSpace on 2016-05-11T14:21:12Z (GMT). No. of bitstreams: 1 Thesis-1994-Jacob.pdf: 26119019 bytes, checksum: b8e19fd69a5cb720e5071df7ae1b03bb (MD5) Previous issue date: 1994 / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Departamento de Entomologia. Rio de Janeiro, RJ, Brasil. / A dual phase gas diffusion-FIA system containing a tubular PTFE-membrane was studied as a mean of producing gas samples for routine 15N/14N isotopic ratio mass spectrometry. The method is based on Rittenberg's reaction; the ammonium sample is injected into a liquid alkaline stream containing hypobromite and the N2 gas produced in the reaction diffuses across a PTFE-membrane into a helium carrier stream which carries it to the detector. Initially here, the use of a tubular microporous PTFE-membrane as a device for the preconcentration of samples in aqueous solutions was investigated. The performance of such a membrane was studied under a variety of operating conditions. A qualitative model of the membrane mechanism was developed based on the diffusion transport of vapour away from the contained liquid surface through the connected pore space. The dispersion undergone by the sample in the GD-FIA system containing this preconcentration unit was also studied and this FIA system was applied as a practical device for the determination and speciation of aluminium in a river water sample. The procedure for generating nitrogen gas involved optimisation of the system parameters including the oxidation reaction step and the production on-line of the chemicals used. The nitrogen gas was generated easily and rapidly, allowing a sample throughput capability of the order of 20 h-1. The system was applied to the determination of total nitrogen content in agricultural sample prepared by the Kjeldahl digestion. The method offered precision and accuracy comparable to those of the standard distillationtitration procedure. Isotope ratios were determined with good precision and means for obtaining accuracy comparable with established techniques were developed. It was also shown that the DPGD-FIA system can be readily adapted to enable different forms of nitrogen e. g. N02-, N03- and NH4+ to be determined.

Page generated in 0.1009 seconds