• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 51
  • 11
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 159
  • 159
  • 139
  • 68
  • 63
  • 62
  • 59
  • 56
  • 25
  • 21
  • 19
  • 19
  • 17
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estabilização de Cu(III) em meio contendo peptídeos: estudos eletroquímicos e aplicações analíticas / Stabilization of Cu (III) in medium containing peptides: electrochemical studies and analytical applications

Lowinsohn, Denise 05 May 2003 (has links)
Neste trabalho são apresentados alguns resultados relacionados a estudos sobre o comportamento eletroquímico do Cu(II) em meio contendo diferentes peptídeos (tri, tetra e pentaglicina) em função da acidez utilizando-se voltametria cíclica. Os experimentos foram realizados em uma faixa de pH entre 7,0 e 10,0. Experimentos espectrofotométricos e coulométricos também foram feitos, ambos para se caracterizar as espécies de Cu(II) e Cu(III) em solução e provar a existência da degradação dos complexos de Cu(III). Além disso, experimentos para esses sistemas também foram realizados em diferentes temperaturas utilizando eletrodo rotativo na configuração disco-anel. Estudos eletroanalíticos demonstraram a potencialidade de se empregar o sistema Cu(II)/Cu(III) no desenvolvimento de metodologia eletroanalítica para a determinação de sulfito. Neste contexto, um método amperométrico indireto para a determinação de sulfito em fluxo é proposto neste trabalho. O método baseia-se na medida amperométrica (OV vs Ag/AgCI (sat. NaCI)) do Cu(III) gerado quimicamente no processo de auto¬-oxidação do S(IV) em soluções de Cu(II)/tetraglicina na presença de traços de Ni(II) utilizando uma célula em fluxo com sistema adequado para separação de gases. A oxidação espontânea do complexo pelo oxigênio dissolvido e S(IV) é muito lenta ao contrário do que ocorre quando há traços de Ni(II). A faixa de trabalho foi de 20-100 µmoIL-1 com limite de detecção de 2µmoIL-1 (S/N=3). A repetibilidade para a determinação (100µmoIL-1) levou a um desvio de 4,9% (n = 38), valor superior aos encontrados na literatura para determinações de sulfito em vinho por FIA com detecção amperométrica indireta (1-4,6%), e a freqüência analítica foi de 40h-1, valor coerente com os dos outros métodos amperométricos. Ambas as análises de sulfito em amostras de vinhos e de sucos tiveram seus resultados comparados com aqueles obtidos utilizando-se o método padrão. / The electrochemistry of Cu(II) in aqueous solutions containing triglycine, tetraglycine and pentaglycine had been investigated at glassy carbon surfaces. Experiments were carried out in the pH range between 7.0 and 10.0. A correlation between voltammetric waves and the nature of the Cu(II) species involved in the electrochemical steps was performed. Spectrophotometric and coulometric studies were also done to characterise Cu(II) and Cu(III) species in solution and prove the existence of a degradation step related to Cu(III) complexes. Rotating ring-disc voltammetry was employed to follow this chemical step coupled to the electrode reaction, at three different temperatures. Data show that Cu(III)/triglycine species degrade, with faster kinetics, when the results are compared with those obtained for tetraglycine and pentaglycine. An indirect amperometric method for the determination of sulfite in a flow injection configuration is described. The method is based on the amperometric measurement (OV vs Ag/AgCI (sat. NaCI)) of Cu(III) chemically generated by the sulfite induced autoxidation of Cu(II)/tetraglycine complex in the presence of traces of Ni(II) with a manifold that incorporates flow extraction of sulfite as SO2 through a PTFE membrane. The operational range was 2µmoIL-1 with a detection limit of 2µmolL-1 (S/N = 3). The repeatability for the determination (100 2µmolL-1) was evaluated to be 4.9% (n = 20) and the analytical frequency was 40h-1. Results for 3 wines and 2 juices samples showed excellent agreement with those obtained by using a recommended procedure for sulfite analysis.
82

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

André Fernando Lavorante 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
83

Polímeros molecularmente impressos (MIPs) como extratores em fase sólida em sistemas de análises em fluxo / Molecularly imprinted polymers (MIPs) as solid phase extractors in flow systems

Viviane Grassi 23 June 2008 (has links)
Polímeros molecularmente impressos (MIPs) se afiguram como materiais promissores a serem empregados em extração em fase sólida devido à boa seletividade apresentada por eles. A seletividade dos MIPs está diretamente relacionada ao reconhecimento pelo polímero de uma molécula de interesse, a qual foi empregada previamente como molde no processo de sua síntese. MIPs apresentam como características o fácil preparo, o baixo custo, a possibilidade de síntese em ambientes adversos, e a resistência química na presença de ácidos, bases, íons metálicos, solventes orgânicos bem como resistência física a altas temperaturas e pressões. Neste trabalho, a exploração de MIPs como extratores para separação em fase sólida (SPE) em sistemas de análises em fluxo foi realizada, sendo suas características e desempenho avaliados em relação às determinações espectrofotométricas de catecol, ácico ascórbico e atrazina em amostras de relevãncia ambiental, farmacológica e alimentícia. A possibilidade de separação quiral foi também investigada em relação D e L-ácido ascórbico. Potencialidades e limitações quanto ao emprego dos mesmos em sistemas de análises em fluxo foram observadas e enfatizadas / Molecularly imprinted polymers (MIPs) are promising as material to be used in solid phase extractions due to their high selectivity. MIPs selectivity is directly related to the recognition of a molecule of interest, which was previously employed as template in the synthesis process. The main favorable characteristics of MIPs are the easy preparation, low cost, possibility of synthesis in adverse environments, and chemical resistance in the presence of acids, bases, metal ions, organic solvents as well as the physical resistance to high temperatures and pressures. In the present work, flow systems with molecularly imprinted polymers as in-line solid phase extractors were designed, and their characteristics and efficiencies were assessed in relation to the spectrophotometric determinations of the catechol, ascorbic acid and atrazine in environmental, pharmacological and food samples. Moreover, the feasibility of chiral separation was investigated in relation to D and L-ascorbic acid. Potentialities and limitations of implementing MIPs in flow analysis were highlighted
84

Estudos espectrofotométricos e por quimiluminescência da autoxidação de complexos de Ni(II) ou Cu(II)/tetraglicina induzida por S(IV). Aplicações analíticas / Spectrophotometric and chemiluminescence studies of S(IV) induced autoxidation of Ni(II) or Cu(II)/tetraglycine complexes. Analytical applications.

Rodrigo Leandro Bonifacio 13 May 2004 (has links)
O presente trabalho apresenta estudos da reação de autoxidação de Ni(II)/tetraglicina ou Cu(II)/tetraglicina induzida por S(IV). Estudos espectrofotométricos enfocaram a formação do respectivo íon metálico no estado de oxidação 3+. Verificou-se que S(IV) acelera a autoxidação de Ni(II)/tetraglicina em pH=9,2 (tampão borato), com a determinação de alguns parâmetros cinéticos desta reação. A autoxidação de Cu(II)/tetraglicina induzida por S(IV), caracterizada por efeito sinérgico positivo de Ni(II), foi empregada no desenvolvimento de método analítico para S(IV) na faixa de (0-0,12) milimolar. Este método foi utilizado para estudo da autoxidação de S(IV) catalisada por traços de íons metálicos de transição, em meio não-complexante. Estudos por quimiluminescência abordaram a interação das espécies geradas na autoxidação de Ni(II)/tetraglicina e Cu(II)/tetraglicina induzida por S(IV) com o íon tris-bipiridil-2,2´-rutênio(II). Foi avaliado o efeito de intensificação da radiação emitida, causado por tensoativos ou adições sucessivas de S(IV). A interação das espécies produzidas na autoxidação de Ni(II)/tetraglicina induzida por S(IV) com luminol foi aproveitada para desenvolvimento de método quimiluminescente para determinação de sulfito. O método proposto foi aplicado para determinação de S(IV) livre em amostras de bebidas, açúcar e água de chuva (limite de detecção 0,28 nanomolar). / The current work shows studies concerning the sulfite induced Ni(II)/tetraglycine (NiIIG4) and Cu(II)/tetraglycine (CuIIG4) autoxidation reaction in aqueous medium. Spectrophotometric studies focused on the formation of the correspondent metallic ion in the 3+ oxidation state. It was found that S(IV) accelerates NiIIG4 autoxidation at pH = 9.2 (borate buffer). Some kinetic parameters of this reaction have been successfully determined. S(IV) induced CuIIG4 autoxidation, which is characterized by the remarkable positive synergistic effect of Ni(II), was used in the development of a S(IV) analytical method in the range of (0-12)x10-5 mol L-1. This method was used to study the S(IV) catalyzed autoxidation of metallic transition ions, in non-complexing medium. Chemiluminescence studies approached the interaction between Ru(II)/bipy (tris-bipyridil-2,2´-ruthenium(II) ion) and the species generated in the S(IV) induced NiIIG4 autoxidation. The emitted radiation intensifying effect, which is caused by the presence of certain surfactants or consecutive additions of S(IV), was evaluated. The interaction between the species generated in the S(IV) induced NiIIG4 autoxidation and luminol was used in the development of a sulfite determination method by chemiluminescence. A flow system containing a gas-diffusion unit was used to separate S(IV) from the matrix. Free sulfite was determined in beverages, sugar and rainwater samples, with a detection limit of 2,8 x 10-8 mol L-1.
85

Desenvolvimento de um fotômetro portátil e de procedimentos analíticos automáticos para determinação de ânions e cátions em fontes de captação de águas para uso doméstico e industrial / Development of portable photometer and automatic analytical procedures for anions and cations determination in sources of water captation for domestic and industrial uses

Feres Junior, Mario Almir 18 December 2006 (has links)
Neste trabalho, foi desenvolvido equipamento portátil e procedimentos analíticos automáticos para determinação de cátions e anions em águas usadas para consumo humano e suprimento. Os procedimentos foram baseados no processo de multicomutação em fluxo e detecção fotométrica empregando fotômetro feito no laboratório. Os sistemas de fluxo foram construídos empregando válvulas solenóide, com interface independente de comutação acionadas por computador usando apenas um canal de bombeamento. O sistema proposto foi controlado por um computador rodando um software escrito em QuickBasic 4.5. Os dói fotômetros baseados em LED foram desenvolvidos usando como detectores de radiação foto-transistores e foto-diodos. Nos dois casos a fonte de radiação (LED) e o foto-detector foram acoplados a cela de fluxo obtendo assim, uma unidade compacta. O fotômetro foi projetado para usar um foto-transistor para determinações seqüenciais de nitrato, nitrito, ferro(II), ferro(III) em águas de rios.O fotômetro proposto usa um foto-diodo para determinação de cloreto por turbidimetria, fosfato e amonium por fotometria. A sistema de fluxo foi desenhado associando-se os processos de multicomutação e multisite garantindo redução de reagente e de efluente. O sistema sistema foi empregado para determinação de cloreto, fosfato e amônio em águas de rios. Os dois sistemas propostos apresentaram excelente performance incluindo boa precisão, freqüência analítica e baixo consumo de reagente. Além disso, o sistema baseado em multisite apresentou baixo volume de efluente gerado. As dimensões reduzidas de ambos os fotômetros e do modulo de analise em fluxo, permitiram a portabilidade, o que possibilita sua aplicação em condições de campo. / In this work it was developed a portable apparatus and automatic analytical procedures for the determination of cations and anions in waters used for human consumption and industrial provisioning. The procedures were based on the multicommutation process in flow analysis and detection was performed using a homemade photometer. The flow systems were designed employing a set of solenoid valves, which were assembled to work as independent commutation units, thus under computer control several solutions were handled using a single pumping channel. The proposed system was controlled by computer running a software wrote in QuickBasic 4.5. The two LED based photometers were developed using as light detection a phototransistor and a photodiode. In both cases, the radiation source (LED) and the photodector were coupled to the flow cell in order to obtain compact unit. The photometer designed using a phototransistor was employed for the sequential determination of nitrate, nitrite, iron(II) and iron(III) in river water. The photometer designed using a photodiode was employed in the system used for the determination of chloride by turbidimetry, phosphate and ammonium by photometry. The flow system was designed associating the multisite and multicommutation process intending reduction of the reagent consumption and waste generation. The useful of the system was proved performing the determination of chloride, ammonium and phosphate in river water. The two proposed systems presented very overall performance including precision and accuracy, analytical frequency and low reagent consumption. Furthermore, the system based on multisite approach presented a very low volume of waster generation. The reduced dimensions of both photometer and flow system module allow their portability, thus we can suggest that the proposed systems are reliable for work in field condition.
86

Réalisation d'électrodes enzymatiques à réponse rapide pour l'analyse par injection en flux continu (FIA).‎ Application au suivi en ligne de la production de pénicilline par fermentation

Meier, Helmut 25 June 1993 (has links) (PDF)
Ce travail concerne la réalisation d'une électrode enzymatique utilisable pour le suivi en ligne (<i>on-line</i>) d'un procédé de fermentation. Cette étude a nécessité la mise au point d'une nouvelle technique d'immobilisation, applicable à différentes enzymes. Elle est basée sur la formation de liaisons covalentes entre l'enzyme et l'agent portant: le glutaraldéhyde. La méthode consiste en une adsorption de l'enzyme suivie du dépôt, par vaporisation, de l'agent réticulant sur l'extrémité sensible des électrodes de pH en verre. Ce procédé d'immobilisation assure un temps de réponse extrêmement court du biocapteur. Cette performance est un avantage indéniable pour des mesures en continu, tel qu'un système d'analyse par injection en flux continu (FIA). Par la suite, nous avons développé des systèmes FIA incorporant trois différents types de cellules de détection appropriées aux besoins analytiques. Des électrodes à pénicillinase et à uréase, préparées selon la méthode décrite ci-dessus, ont été installées et utilisées dans ces cellules. Les systèmes biocapteurs-FIA, ainsi conçus, ne nécessitent alors ni réacteur enzymatique, ni réactif. De plus, le temps de réponse très court du biocapteur allie aux avantages de la FIA et aux spécificités des cellules a permis d'obtenir une cadence de mesure très élevée. Ce système d'analyse a été applique aux mesures en ligne de la concentration de pénicilline au cours de sa production fermentaire et aux mesures automatiques de l'urée dans les échantillons de sérum humain. Pour cela, nous avons automatise le système biocapteur-FIA et conçu une nouvelle cellule a écoulement agite pour l'installation des électrodes à uréase et a pénicillinase. Ce système biocapteur-FIA donne des résultats satisfaisants pour la détermination de l'urée et surtout s'est révélé extrêmement performant pour le suivi hors ligne et en ligne de la concentration de pénicilline pendant plusieurs fermentations d'une durée de 250 heures environ. Dans ce dernier cas, la comparaison des mesures effectuées avec le système biocapteur-FIA et une méthode classique de dosage (HPLC) est favorable à l'analyseur biocapteur-FIA qui assure des mesures en ligne avec une bonne fiabilité et a un moindre cout, mais aussi en raison de sa simplicité. En rendant possible une exploitation immédiate des mesures en ligne de la concentration en pénicilline par l'ordinateur central de l'installation fermentaire, le système biocapteur-FIA présente un pas important dans l'amélioration du contrôle et/ou de la modélisation des bioprocédés.
87

Determination Of Silver By Chemical Vapour Generation And Atomic Absorption Spectrometry

Ozturk, Cagla Pinar 01 September 2004 (has links) (PDF)
A method for determination of silver has been developed based on chemical vapour generation atomic absorption spectrometry (CVGAAS). Volatile species of silver in acidified medium were generated by the reduction of sodium tetrahydroborate / these species were sent to a flame-heated quartz tube atomizer (QTA) following isolation by using a gas-liquid separator. Flow injection (FI) was used for sample introduction. Optimization of parameters such as / concentrations of acid and NaBH4 concentration, flow rates of solutions and carrier gas were made. The influences of the well-known chemical modifier, Pd, and the effect of diethyldithiocarbomate (DDTC) were also examined. Interference study has been carried out for Ni(II), Co(II), Cu(II), Fe(III), Au(III), As(III), Pb(II), Se(IV) and Sn(II) . A detection limit of 7.5 ng mL-1 (n=11) was obtained with a 0.2 mL sample volume. With the FI-CVGAAS system 5.6 times sensitivity enhancement was achieved over flame atomic absorption spectrometry (FAAS).
88

Desenvolvimento de procedimento analítico para determinação de paracetamol em formulações farmacêuticas empregando análise por injeção em fluxo e detecção espectrofotométrica. / Development of analytical procedure for determination of paracetamol in pharmaceutical formulations employing flow injection analysis and spectrophotometric detection.

Gonsalves, Arlan de Assis 18 April 2008 (has links)
The quantification of active principles is an indispensable stage of medicines quality control. For that reason a number of methodologies intended for pharmaceutical applications is constantly growing up. Thus, in view of great analysis demands, the development of low-cost, fast and automatized procedures is very useful. In this way, the present work proposes an analytical procedure for determination of paracetamol in pharmaceutical formulations employing Flow Injection Analysis (FIA) coupled to spectrophotometric detection. Interests for paracetamol is due to its large use as analgesic/antipyretic in Brazil. The proposed procedure is based on diazo-coupling reaction between sulfanilic acid and paracetamol in alkaline medium which forms an orange-reddish diazocompound that absorbs intensively at 500 nm. Optimization studies were carried out with experimental parameters and plotting a reference curve for determination of paracetamol. The linear work range including concentrations between 4.00 and 16.00 mg L-1 of paracetamol, with a correlation coefficient of 0.9991. The limit of detection for the considered work range shown be equal to 0.30 mg L- 1. The relative standard deviation to 10 replicates of the standard solution containing 8.00 mg L-1 of paracetamol was 1.28 %. The real sample analysis by the proposed procedure and by the official method demonstrated comparables results. The nominal amounts of paracetamol declared by the fabricants on the label of all analyzed pharmaceuticals formulations showed good agreement with the official specifications. Recovery studies in real samples revealed a mean rate of 97.1 % of the paracetamol standard added, assuring in such way the confidence of the proposed procedure. Studies realized in this work makes evident the viability of the use of the proposed procedure for determination of paracetamol, since this method has adopted an simple mechanized system, practice and produce results that do not differ significatively from the official method. Other advantages related at this procedure are the use of low toxic reagents and of low cost, good precision (repeatability) and reproducibility, generation of cromogenic product highly stable and suitable sensibility for quality control purposes. / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A quantificação de princípios ativos é uma etapa indispensável do controle de qualidade de medicamentos, e em virtude disto, o número de metodologias desenvolvidas destinadas às aplicações farmacêuticas vem crescendo constantemente, visto que, diante de grandes demandas de análises, o desenvolvimento de procedimentos rápidos, pouco dispendiosos e automatizados é de grande valia. Desta forma, o presente trabalho propõe o desenvolvimento de procedimento analítico para determinação de paracetamol em formulações farmacêuticas empregando Análise por Injeção em Fluxo (FIA) associada à detecção espectrofotométrica. O interesse por este analito reside no fato deste fármaco ser um dos analgésicos/antipiréticos mais utilizados no Brasil. O procedimento proposto baseia-se na reação de diazoacoplamento entre ácido sulfanílico e paracetamol em meio alcalino com formação de um diazocomposto laranja-avermelhado que absorve intensamente em 500 nm. Foram realizados estudos de otimização dos parâmetros experimentais e construída uma curva de referência para determinação de paracetamol. A faixa linear de trabalho compreendem concentrações entre 4,00 e 16,00 mg L-1 de paracetamol, com um coeficiente de correlação de 0,9991. O limite de detecção para a faixa de trabalho considerada mostrou-se igual a 0,30 mg L-1. O desvio padrão relativo para 10 replicatas da solução padrão contendo 8,00 mg L-1 de paracetamol foi 1,28 %. As análises das amostras reais pelo procedimento proposto e pelo método oficial demonstraram resultados comparáveis. Os teores nominais de paracetamol declarados pelos fabricantes nos rótulos de todas as formulações farmacêuticas analisadas mostraram conformidades com as especificações oficiais. Estudos de recuperação em amostras reais revelaram uma taxa média de 97,1 % do padrão de paracetamol adicionado, garantindo desta forma a confiabilidade do procedimento proposto. Os resultados alcançados neste trabalho evidenciaram a viabilidade do emprego do procedimento proposto para a determinação de paracetamol, uma vez que este método adotou um sistema mecanizado simples, prático e quando aplicado para a quantificação de paracetamol em amostras comerciais produziu resultados que não diferiram significativamente do método oficial. Outras vantagens relacionadas a este procedimento são o uso de reagentes pouco tóxicos e de baixo custo, boa precisão (repetibilidade) e reprodutibilidade, geração de produto cromogênico altamente estável e com sensibilidade adequada para propósitos de controle de qualidade.
89

Estratégias para a determinação de minoxidil

Sousa, Rogério Adelino de 04 September 2009 (has links)
Made available in DSpace on 2016-06-02T20:34:18Z (GMT). No. of bitstreams: 1 2757.pdf: 3606841 bytes, checksum: 1cbaf9d57ef931332c3b9f278a479c5a (MD5) Previous issue date: 2009-09-04 / Universidade Federal de Sao Carlos / In this work methods for determining minoxidil (MX) in commercial samples and electrolytes of synthetic plasma and urine are presented. The minoxidil is a pharmaceutical whose blood vessel dilation property is used in the treatment of the Arterial Hypertension and in the treatment of the Alopécia Areata. Three commercial samples were analyzed, the Regaine® (Pharmacia, USA) and the magistral formulation (Porto Bianco, Brazil) both are topical use solutions, in a mixture of ethanol and propilenoglicol as vehicle, containing 2 % (20 mg mL-1) and 5 % of minoxidil (50 mg mL-1) respectively, and Loniten® (Rhodia, Brasil) containing 10 mg of MX per tablet. Three proposals for the determination of minoxidil in commercial samples and electrolytes of synthetic plasma and urine were considered. The first procedure was the determination of MX in the samples using flow injection analysis with spectrophotometric detection in two setups. For the setup procedure using single line with a wavelength of 400 nm, which can quantify the MX present in samples, showing recovery values of 99.7 and 104.8 % for Loniten® and the Regaine® respectively, and 102.5 % for the magistral sample. In merging-zones setup, the detection was in 345 nm, the MX was determined in the samples with recovery 101.3 % for Loniten® and 99.8 % to Regaine® and 103.7 % for the magistral. For both configurations, all the results from flow agree with the labeled values and the results from the chromatographic method (comparative method) in 95 % confidence (t-Student test). In the second procedure, an electroanalytical determination of MX is described using two composite electrodes, the graphite-polyurethane (GPUE) and graphite-silicone rubber (GSRE). Cyclic voltammetry was used to study the electroactive area of electrodes (GPUE = 0.093 cm2; GSRE = 0.089 cm2), the diffusion coefficient of MX (in order of 8.0 x10-6 cm2 s-1) and to study the mechanism of electro-oxidation of MX of which involves one electron per proton. With the support of analytical curves were determined the levels of MX in the samples by different voltammetric techniques; cyclic voltammetry (CV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV). The recovery values are in the range between 96.0 and 110 %, depending on the sample and the voltammetric technique. The electrochemical impedance spectroscopy showed that the mass transport is controlled by diffusion and also there is a weak and reversible adsorption that for both the electrodes. The third method describes the determination of MX and furosemide (FR) using high performance liquid chromatography (HPLC) with spectrophotometric detection. The wavelengths of 275 and 285 nm were for the detection of FR and MX respectively. The mobile phase used was methanol/triethylamine (99:1, V/V) in the flow rate of 0.5 mL min-1. The column used was a C18 Supelco®. The recoveries were 97.7 and 102.4 % for Loniten® and Lasix® respectively. Finally is presented the characterization of the product of oxidation of MX. The informations obtained from infrared spectroscopy technique, were compared with results obtained by nuclear proton magnetic resonance. Two structures were proposed as product of redox reaction between the MX and KMnO4, the desoximinoxidil and another new structure. / No presente trabalho, são apresentados métodos para a determinação minoxidil (MX) em amostras comercias e eletrólitos de plasma e urina sintéticos. O MX é um fármaco que, devido à sua propriedade vasodilatadora, é usado no tratamento da Hipertensão Arterial e no tratamento da Alopécia Areata (calvice). Foram analisadas três amostras comerciais, Regaine® (Pharmacia, EUA), formulação de uso tópico manipulada pela Farmácia de Manipulação Porto Bianco (São Carlos, Brasil) e o Loniten® (Rhodia, Brasil), sendo o primeiro e o segundo soluções de uso tópico contendo 2 % (20 mg mL-1 m/v) e 5 % (50 mg mL-1 m/V) de MX, respectivamente; o terceiro medicamento é apresentado em forma de comprimidos contendo 10 mg de minoxidil, o qual é utilizado no tratamento da hipertensão arterial. Também foram analisados os teores de MX contido nos eletrólitos do plasma e da urina artificiais.Nesse trabalho foram propostas três metodologias para a determinação do MX nas amostras. O primeiro procedimento foi a determinação de MX nas amostras usando análise em fluxo com detecção espectrofotométrica em duas configurações diferentes, as quais monitoraram a formação de um produto amarelado formado a partir da reação entre MX e HNO2 formado in situ. A primeira configuração foi de linha única, com detecção no comprimento de onda de 400 nm, na qual foi possível quantificar o MX presente nas amostras, com recuperações de 99,7 e 104,8 % para o Loniten® e o Regaine®, respectivamente, e 102,5 % para a amostra manipulada. Na segunda configuração, de zonas coalescentes e detecção 345 nm, o MX foi determinado nas amostras com recuperação entre 101,3 % para o Loniten®, 99,8 % para o Regaine ® e 103,7 % para o Manipulado. Observou-se, para ambas as configurações, que todos os resultados do método de análise em fluxo concordam com os valores rotulados das amostras analisadas e com os resultados do método cromatográfico (método comparativo), em 95 % de confiança (teste t-Student). No segundo método, é descrita a determinação eletroanalítica de MX usando dois eletrodos compósitos de grafite-poliuretana (GPUE) e grafiteborracha de silicone (GSRE). Foi usada voltametria cíclica para o obtenção da área eletroativa dos eletrodos (GPUE = 0,093 cm2; GSRE = 0,089 cm2), do coeficiente difusão do MX (na ordem de 8,0x10-6 cm2 s-1) e para estudo do mecanismo da eletro-oxidação da MX, que é de um elétron por próton. Com o auxílio das curvas analíticas, foram determinados os teores de MX contidos nas amostras por diferentes técnicas voltamétricas, voltametria cíclica (CV), voltametria de onda quadrada (SWV) e voltametria de pulso diferencial (DPV), usando ambos os eletrodos. Os valores de recuperação estão no intervalo entre 96,0 e 110 %, dependendo da amostra e da técnica voltamétrica. A espectroscopia de impedância eletroquímica descreveu qual o circuito elétrico foi equivalente à eletro-oxidação do minoxidil e, ainda, mostrou que há adsorção fraca e reversível para ambos os eletrodos. O terceiro método descreve a determinação de MX e furosemida (FR), usando cromatografia líquida de alta eficiência (HPLC) com detecção espectrofotométrica. Os comprimentos de onda de detecção foram 275 e 285 nm para a FR e o MX, respectivamente. A fase móvel usada foi metanol/trietilamina (99:1; V/V) na vazão de 0,5 mL min-1. A coluna usada foi uma C18 da Supelco®. As recuperações foram 97,7 e 102,4 % para o Loniten® e o Furosem®, respectivamente. Finalmente, é apresentada a caracterização do produto de oxidação do MX. Para a caracterização, foi usada a espectroscopia de infravermelho e as informações obtidas foram comparadas com os resultados obtidos na ressonância magnética nuclear de prótons. Foram propostas, através da técnicas IR e RMN, duas estruturas resultantes da reação redox entre o MX e o KMnO4, o desoximinoxidil e uma outra estrutura, inédita na literatura o 3,5-dióxido-2,4- dinitro-6-piperidinopirimidina.
90

Avaliação dos niveis de nitrato e nitrito na alimentação oferecida a trabalhadores de Campinas e Limeira, São Paulo / Evaluation of the levels of nitrate and nitrite in the feeding offered to workers in Campinas and Limeira, São Paulo

Carmo, Antonio Silverio do 13 August 2018 (has links)
Orientador: Felix Guillermo Reyes Reyes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-13T22:13:43Z (GMT). No. of bitstreams: 1 Carmo_AntonioSilveriodo_M.pdf: 527215 bytes, checksum: 30ae91eecb94c7fde3ce55aa4c1ed5cb (MD5) Previous issue date: 2009 / Resumo: O setor de alimentação coletiva para os trabalhadores está em constante expansão no Brasil, destacando-se pela empregabilidade direta e indireta e pela contribuição na renda econômica do país. O PAT (Programa de Alimentação do Trabalhador) foi instituído com o objetivo de melhorar as condições das refeições oferecidas nas empresas aos trabalhadores. O cardápio oferecido contém, dentre outras preparações, saladas, carnes e embutidos de forma geral, por isso a importância de monitorar os saís de nitrito e nitrato nessas refeições. Os sais de nitrato e nitrito estão naturalmente presentes no ambiente, na água e nos vegetais, sendo também utilizados como aditivo alimentar, principalmente como agente antimicrobiano em produtos cárneos. Desta forma os trabalhadores estão sujeito à exposição aos compostos nitrogenados em função do cardápio elaborado. O nitrato é considerado um composto de baixa toxicidade e seu risco à saúde humana depende da sua redução ao nitrito, o qual pode conduzir a metamioglobinemia ou formar compostos N-nitrosos. O Comitê da Organização das Nações Unidas para Agricultura e Alimentação/Organização Mundial da Saúde (FAO/OMS) de Peritos em Aditivos Alimentares (JECFA) estabeleceu uma ingestão diária aceitável (IDA) para nitrato e nitrito de 0-3,7 mg kg-1 de peso corpóreo e de 0-0,07 mg kg-1 de peso corpóreo, respectivamente. No presente trabalho foi validado um método para a determinação de nitrito e nitrato em refeições coletivas utilizando análise por injeção em fluxo (FIA), com determinação espectrofotométrica através da formação do complexo FeSCNNO+. Foram avaliados os seguintes parâmetros analíticos: faixa linear, linearidade, sensibilidade, limite de quantificação e exatidão. O método foi utilizado para a determinação de nitrito e nitrato em refeições oferecidas a trabalhadores de Campinas e Limeira, no Estado de São Paulo. Os teores médios (mínimo e máximo) de nitrito e nitrato nas amostras analisadas foram de 6,25 (4,66 e 9,89) mg kg-1 de nitrito e 35,63 (1,56 e 75,44) mg kg-1 de nitrato. Estimou-se a ingestão de nitrito e nitrato através do consumo do almoço oferecido aos trabalhadores, considerando o teor médio (mínimo e máximo) de nitrito e nitrato nas amostras analisadas, o peso médio dos indivíduos (66 kg) e o peso médio da refeição (400g). Os valores de ingestão média (mínimos e máximos) calculados foram 0,04 (0,02 e 0,05) mg kg-1 peso corpóreo/refeição para nitrito e 0,21 (0,01 e 0,54) mg kg-1 corpóreo /refeição para nitrato. Considerando que o almoço representa 40 % do total de alimentos consumidos diariamente, a ingestão de nitrito, mais não a de nitrato, supera o valor de IDA estabelecido pelo JECFA, o que indica que medidas devam ser tomadas visando minimizar o risco à saúde dos trabalhadores decorrente da ingestão de nitrito / Abstract: The sector of collective meals to the workers is continually expanding in Brazil and stands out for it¿s contribution to the countries economy and the direct and indirect number of associated jobs. The Feeding Worker Program was instituted with the objective of improving the quality of meals offered by companies to workers. Nitrate and nitrite salts are naturally presents in the atmosphere, water and in vegetables, and are also used as food additives, mainly as antimicrobial agents in meat products. Nitrate is considered to have relatively low toxicity and the risk to human health primarily depends on its reduction to nitrite, which can cause methaemoglobinaemia, or form N-nitroso compounds such as nitrosamines that may cause cancers. The menu offered in the Feeder Worker Program usually contains salads, meats and processed food all of which may contain nitrite and nitrate, potentially exposing the workers to these compounds and justifying the monitoring of these compounds in the workers food. The Joint FAO/WHO Committee on Food Additives (JECFA) established an acceptable daily intake (ADI) for nitrate and nitrite of 0-3.7 mg kg-1 of body weight and 0-0.7 mg kg-1 of body weight, respectively. In the present work a method was validated for nitrite and nitrate determination in collective meals using flow injection analysis (FIA), with spectrophotometric determination through the formation of FeSCNNO+. The following performance criteria for nitrite and nitrate were evaluated: linear range, linearity, sensitivity, limit of detection, limit of quantitation and accuracy. The method was used for the determination of nitrite and nitrate in meals offered to workers in Campinas and Limeira, in the State of São Paulo. The average levels (minimum and maximum) of nitrite and nitrate in the analyzed samples were 6.25 (4.66 and 9.89) mg kg-1 for nitrite and 35.63 (1.56 and 75.44) mg kg-1 for nitrate. Considering the daily exposure to nitrite and nitrate through the consumption of the meals offered to the workers, using an average weight of individuals of 66 kg and weight of the average meal eaten of 400 g, the average exposure (minimum and maximum) to nitrite was 0.04 (0.02 and 0.05) mg kg-1 per meal and to nitrate 0.21 (0.01 and 0.54) mg kg-1 per meal. Taking into consideration that lunch represent 40 % of total foods daily consumption, the nitrite intake, but not nitrate, overcome the ADI value established by JECFA, suggesting that measurements should be taken in order to minimize the risk to the workers health due to nitrite intake / Mestrado / Mestre em Ciência de Alimentos

Page generated in 0.0929 seconds