• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 15
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 69
  • 19
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Implementação de um sistema eletrônico para medir taxa de fluência de energia de radiação na faixa de radioterapia com sensor piroelétrico

Pontes, Wesley [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T19:22:12Z : No. of bitstreams: 1 pontes_w_dr_ilha.pdf: 799811 bytes, checksum: 398dc35d3e3ae3ef3dfe294f8ba6793c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Sensores piroelétricos podem ser utilizados para medir a taxa de fluência de energia (intensidade) da radiação X na faixa de diagnóstico médico e de ortovoltagem. Neste trabalho, foi implementado um sistema eletrônico que pode medir taxa de fluência de energia de radiação gama de 1,25 MeV e fótons X de 6 MV e 15 MV. O sistema é constituído por um sensor piroelétrico, um conversor corrente-tensão de alta sensibilidade e um instrumento para registrar a forma de onda e medir o pulso do sinal produzido pelo sensor. Este instrumento pode ser um osciloscópio, um circuito microcontrolado associado a um display de cristal líquido, ou um módulo de aquisição de dados e um laptop. O sensor piroelétrico e o conversor corrente-tensão foram alojados em uma câmara piroelétrica blindada. Seis tipos de sensores piroelétricos foram avaliados, sendo três cerâmicas e três compósitos. Os resultados obtidos com o sistema eletrônico, utilizando os diferentes tipos de sensores, possibilitaram caracterizá-lo em termos de precisão, resolução e sensibilidade. O sistema apresentou resposta linear com a taxa de fluência de energia da radiação, precisão melhor que 3 % e resolução de 5,56 nW/m2. As constantes piezoelétricas d33 dos sensores utilizados não sofreram alteração após os mesmos terem sido irradiados com 45 Gy de radiação na faixa de radioterapia. Estas características, associadas à importância de se medir a taxa de fluência de energia de radiação ionizante, podem tornar o instrumento piroelétrico muito útil no monitoramento de radiação produzida por equipamentos de radioterapia / Pyroelectric sensors have been be used to measure the energy fluence rate (intensity) of x-radiation in the range of medical diagnosis and orthovoltage. In this work, we implemented an electronic system that can measure the energy fluence rate of 1.25 MeV gamma radiation, 6 MV and 15 MV X-photons. The system consists of a pyroelectric sensor, a high sensitivity current-to-voltage converter and an instrument for measuring and recording the waveform of pulses produced by the pyroelectric sensor. This instrument may be an oscilloscope, a microcontrolled circuit associated with a liquid crystal display, or a data acquisition module connected to a laptop. The pyroelectric sensor and the current-tovoltage converter were placed in an shielded pyroelectric camera. Six types of pyroelectric sensors were evaluated, three ceramics and three composites. The results obtained with the electronic system, using different types of sensors, allowed us to characterize it in terms of precision, resolution and sensitivity. The system has linear response to the energy fluence rate of radiation, precision better than 3 % and resolution of 5,6 nW/m2. The piezoelectric constant d33 of the sensors used have not changed after these have been irradiated with 45 Gy of radiotherapy radiation. These characteristics, associated with the importance of measuring the ionizing radiation energy fluence rate may make the pyroelectric instrument very useful in monitoring radiation produced by radiotherapy equipments
62

Real-time scheduling of dataflow graphs / Ordonnancement temps-réel des graphes flots de données

Bouakaz, Adnan 27 November 2013 (has links)
Les systèmes temps-réel critiques sont de plus en plus complexes, et les exigences fonctionnelles et non-fonctionnelles ne cessent plus de croître. Le flot de conception de tels systèmes doit assurer, parmi d’autres propriétés, le déterminisme fonctionnel et la prévisibilité temporelle. Le déterminisme fonctionnel est inhérent aux modèles de calcul flot de données (ex. KPN, SDF, etc.) ; c’est pour cela qu’ils sont largement utilisés pour modéliser les systèmes embarqués de traitement de flux. Un effort considérable a été accompli pour résoudre le problème d’ordonnancement statique périodique et à mémoire de communication bornée des graphes flot de données. Cependant, les systèmes embarqués temps-réel optent de plus en plus pour l’utilisation de systèmes d’exploitation temps-réel et de stratégies d’ordonnancement dynamique pour gérer les tâches et les ressources critiques. Cette thèse aborde le problème d’ordonnancement temps-réel dynamique des graphes flot de données ; ce problème consiste à assigner chaque acteur dans un graphe à une tâche temps-réel périodique (i.e. calcul des périodes, des phases, etc.) de façon à : (1) assurer l’ordonnançabilité des tâches sur une architecture et pour une stratégie d’ordonnancement (ex. RM, EDF) données ; (2) exclure statiquement les exceptions d’overflow et d’underflow sur les buffers de communication ; et (3) optimiser les performances du système (ex. maximisation du débit, minimisation des tailles des buffers). / The ever-increasing functional and nonfunctional requirements in real-time safety-critical embedded systems call for new design flows that solve the specification, validation, and synthesis problems. Ensuring key properties, such as functional determinism and temporal predictability, has been the main objective of many embedded system design models. Dataflow models of computation (such as KPN, SDF, CSDF, etc.) are widely used to model stream-based embedded systems due to their inherent functional determinism. Since the introduction of the (C)SDF model, a considerable effort has been made to solve the static-periodic scheduling problem. Ensuring boundedness and liveness is the essence of the proposed algorithms in addition to optimizing some nonfunctional performance metrics (e.g. buffer minimization, throughput maximization, etc.). However, nowadays real-time embedded systems are so complex that real-time operating systems are used to manage hardware resources and host real-time tasks. Most of real-time operating systems rely on priority-driven scheduling algorithms (e.g. RM, EDF, etc.) instead of static schedules which are inflexible and difficult to maintain. This thesis addresses the real-time scheduling problem of dataflow graph specifications; i.e. transformation of the dataflow specification to a set of independent real-time tasks w.r.t. a given priority-driven scheduling policy such that the following properties are satisfied: (1) channels are bounded and overflow/underflow-free; (2) the task set is schedulable on a given uniprocessor (or multiprocessor) architecture. This problem requires the synthesis of scheduling parameters (e.g. periods, priorities, processor allocation, etc.) and channel capacities. Furthermore, the thesis considers two performance optimization problems: buffer minimization and throughput maximization.
63

Comprehensive Investigation of Energy Fluence Spectra and MLC Modeling Parameters and their Effects on Dose Calculation Accuracy in Pinnacle

Bashehab, Ali Jameel 10 1900 (has links)
<p>The main focus of this work is to improve the existing clinical machine model within the Pinnacle software planning system (at Juravinski Cancer Center, Hamilton, CA). The incident energy fluence spectrum exiting from the accelerator head is considered an important element of the machine model. Relying on the Pinnacle auto modeling function to determine the relative photon fluence spectrum based on percent depth dose curves fitting for various filed sizes, led to different solutions when the process cycle were repeated. This work presents a new method for determining the Pinnacle photon energy fluence spectrum based on 6 MV Varian 21EX machine. A Monte Carlo simulation spectrum based on BEAMnrc code was attenuated to various depths of water. We determine that, the BEAMnrc spectrum attenuated by 15 cm of water gives the closest agreement between the computed and measured depth dose, similar to the clinical machine spectrum.</p> <p>Implementing the novel spectrum into a machine that retained the same modeling parameters as the clinical machine (21ex-JCC) shows a slight better calculation of the output factor. The MLC model parameters were also investigated, however, adjusting the MLC offset table was found to give significant improvements, especially for the small field geometries.</p> <p>The full impact of adjusting the photon energy spectrum, Off-Axis Softening Factor, MLC rounded leaf tip radius and MLC calibration offsets were investigated individually, resulting in a good model parameter fit. Several proposed supplementary setups were created to further assess our model. This include a geometry sensitive to MLC abutment leakage, the calculation of output factors for long and narrow MLC defined fields, and small square MLC and jaws defined fields. A Sun-Point diode detector was used in the measurement of the output factors for its accurate precision at small geometries. In addition, a GAFCHROMIC EBT2 film dosimetry was used in the measurement of the MLC abutment leakage.</p> <p>Our new model shows superior results in comparison to the clinical 21ex-JCC machine model, especially with MLC small field calculations. We conclude that relying on PDD curves and dose profiles validation method in assessing the model might not necessarily lead to the best machine parameters, since these are not sensitive to subtle changes in parameters that have important dosimetric consequences.</p> / Master of Science (MSc)
64

Réorganisation neurofonctionnelle permettant le maintien des habiletés d’évocation lexicale lors du vieillissement

Marsolais, Yannick 12 1900 (has links)
Le maintien de performances cognitives optimales au cours du vieillissement a été associé à des changements adaptatifs au niveau de l’activité cérébrale relative à diverses habiletés qui tendent à décliner avec l’âge. Peu d’études ont toutefois évalué cette réorganisation neurofonctionnelle dans le cadre des habiletés de communication, notamment en ce qui concerne le langage expressif. Or, considérant que plusieurs composantes langagières demeurent généralement intègres chez les aînés, il s’avère nécessaire d’explorer davantage les mécanismes cérébraux sous-jacents afin de mieux cerner les déterminants du vieillissement cognitif réussi. L’objectif de la présente thèse est d’examiner en détail les effets de l’âge sur les patrons d’activations et les interactions fonctionnelles entre les substrats neuraux contribuant aux habiletés de communication expressive. Deux études en neuroimagerie fonctionnelle, ayant recours à des approches méthodologiques distinctes, ont ainsi été menées à l’aide d’un paradigme mixte novateur et d’une tâche auto-rythmée d’évocation lexicale sémantique et orthographique, effectuée par des participants jeunes et âgés présentant plusieurs années de scolarisation. S’intéressant spécifiquement aux patrons d’activations associés à un rendement élevé à cette tâche, la première étude révèle que le maintien des habiletés d’évocation lexicale lors du vieillissement s’accompagne de changements neurofonctionnels superficiels chez les adultes âgés performants. Par contre, la seconde étude indique que les interactions fonctionnelles entre les régions corticales contribuant aux productions lexicales déclinent considérablement avec l’âge, sans qu’il y ait toutefois d’impact au plan comportemental. Cet effet du vieillissement sur l’intégration fonctionnelle du réseau de l’évocation sémantique et orthographique est aussi exacerbé par la difficulté de la tâche, ce qui s’exprime par des perturbations locales de la connectivité fonctionnelle. Somme toute, cette thèse démontre qu’une réorganisation neurofonctionnelle afin de maintenir les habiletés d’évocation lexicale au cours du vieillissement s’avère superflue chez les adultes âgés instruits et performants, et ce, malgré une diminution des interactions fonctionnelles au sein des réseaux corticaux sous-jacents. Ces résultats reflètent possiblement une perte d’efficience neurale avec l’âge, toutefois insuffisante pour avoir un impact comportemental chez des individus bénéficiant de facteurs de protection susceptibles de favoriser le vieillissement réussi, ce qui est discuté à la lumière du concept de réserve cognitive. / The maintenance of optimal cognitive performance in aging has been associated with adaptive changes in cerebral activation patterns for various abilities that tend to decline with age. Yet, few studies have investigated this neurofunctional reorganization based on communication abilities, particularly with regard to the expressive side of language. Considering that a number of language components usually remain well preserved in older adults, it is, however, necessary to further explore the underlying cerebral mechanisms to better understand the determinants of successful cognitive aging. The objective of this thesis is to examine in detail the effects of aging on activation patterns and functional interactions among neural substrates contributing to expressive communication abilities. Two functional neuroimaging studies, using distinct methodological approaches, have been conducted by means of an innovative mixed design and an overt self-paced semantic and orthographic verbal fluency task, performed by well-educated young and older adults. Specifically focusing of cerebral activation patterns associated with high levels of verbal fluency performance, the first study shows that the relative preservation of lexical speech production abilities in aging is characterized by marginal neurofunctional changes in high-performing older adults. Yet, the second study indicates that functional interactions between cortical areas contributing to speech productions significantly decrease with age, without, however, having an impact at the behavioral level. In addition, this effect of aging on the functional integration of the network engaged during semantic and orthographic verbal fluency was found to be exacerbated by task demands, which is expressed by local functional connectivity disruptions. In sum, this thesis demonstrates that a neurofunctional reorganization to maintain lexical speech production abilities in aging is unnecessary in well-educated and high-performing older adults, despite an age-related decrease in functional networks integration. These results may reflect a loss of neural efficiency with age, although insufficient to have behavioral outcomes in individuals who benefited from protective factors known to promote successful aging, which is discussed in light of the concept of cognitive reserve.
65

Etude IRMf de la plasticité cérébrale des réseaux moteurs et cognitifs dans la Sclérose Latérale Amyotrophique / fMRI study of cerebral plasticity of motor and cognitive networks in Amyotrophic Lateral Sclerosis

Poujois, Aurélia 31 October 2011 (has links)
Ce travail a porté sur les remaniements corticaux précoces des circuits moteurs et extramoteurs dans la SLA grâce à l’étude des activations IRMf issues de tâches motrices et cognitives. La première partie de nos travaux nous a permis de montrer grâce des tâches simples d’activation motrice en IRMf (1) qu’alors que les patients SLA présentaient un déficit moteur discret, une augmentation des activations corticales est apparue dans les aires sensorimotrices bilatérales du cerveau. (2) Ces modifications précoces de l’activité neuronale étaient corrélées à la latéralisation du déficit moteur du membre ou la prédominance manuelle et surtout, (3) au taux de progression de la maladie à un an et à la survie, suggérant que ce remaniement de l’activité qui correspond probablement à de la plasticité cérébrale a des implications fonctionnelles. Enfin, (4) ce phénomène apparaissait actif puisqu’il s’est poursuivi pendant au moins onze mois. Dans la deuxième partie, nous avons montré lors d’une tâche de fluence verbale silencieuse que (1) les SLA présentaient une suractivation initiale des aires dévolues au processus sémantique avec un renforcement de la connectivité fonctionnelle entre les réseaux (CFR). (2) Au bout de onze mois et alors que l’atteinte des fluences était stable, ce phénomène de compensation s’épuisait avec une diminution conjointe de l’activation des réseaux et de la CFR. La tâche de 2-Back, réalisée alors que les patients ne présentaient pas d’atteinte de la mémoire de travail lors des tests psychométriques, nous a permis de montrer en outre que certains circuits non-moteurs se réorganisaient très précocement chez les patients, alors même qu’ils étaient asymptomatiques / In this work we used motor and cognitive tasks in an fMRI study to explore the early cortical reorganizations of the motor and extra-motor circuits in ALS patients. In a first part, using a simple motor task, we demonstrated (1) that increased cortical BOLD signal changes occurred in specific regions of the brain of ALS patients when their motor deficit was still moderate, and that this early signal changes correlated with (2) the lateralisation of the motor deficit or hand predominance and, more importantly, (3) with the rate of disease progression at one year and survival time, suggesting that modulations of cerebral activity in ALS may have functional implications. Furthermore, (4) this brain plasticity was maintained with time and disease progression during at least eleven months. In a second part, we demonstrated during a silent verbal fluency task (1) that ALS patients presented initially an increased cortical activation of areas devolved to the semantic process with an intensification of the functional network connectivity (FNC). (2) After eleven months and while their performance in tests of verbal fluency was stable, this cerebral compensation ran out with a decrease of the previous cerebral activations and the FNC. A N-back working memory paradigm, realized while the patients did not present any deficit of their working memory, allowed us to show that certain non-motor circuits were reorganized prematurely while patients were still asymptomatic
66

Le caractère adaptatif du cerveau âgé sain dans le maintien des habiletés du traitement lexico-sémantique : une approche neurofonctionnelle

Methqal, Ikram 05 1900 (has links)
No description available.
67

Direct optimization of dose-volume histogram metrics in intensity modulated radiation therapy treatment planning / Direkt optimering av dos-volym histogram-mått i intensitetsmodulerad strålterapiplanering

Zhang, Tianfang January 2018 (has links)
In optimization of intensity-modulated radiation therapy treatment plans, dose-volumehistogram (DVH) functions are often used as objective functions to minimize the violationof dose-volume criteria. Neither DVH functions nor dose-volume criteria, however,are ideal for gradient-based optimization as the former are not continuously differentiableand the latter are discontinuous functions of dose, apart from both beingnonconvex. In particular, DVH functions often work poorly when used in constraintsdue to their being identically zero when feasible and having vanishing gradients on theboundary of feasibility.In this work, we present a general mathematical framework allowing for direct optimizationon all DVH-based metrics. By regarding voxel doses as sample realizations ofan auxiliary random variable and using kernel density estimation to obtain explicit formulas,one arrives at formulations of volume-at-dose and dose-at-volume which are infinitelydifferentiable functions of dose. This is extended to DVH functions and so calledvolume-based DVH functions, as well as to min/max-dose functions and mean-tail-dosefunctions. Explicit expressions for evaluation of function values and corresponding gradientsare presented. The proposed framework has the advantages of depending on onlyone smoothness parameter, of approximation errors to conventional counterparts beingnegligible for practical purposes, and of a general consistency between derived functions.Numerical tests, which were performed for illustrative purposes, show that smoothdose-at-volume works better than quadratic penalties when used in constraints and thatsmooth DVH functions in certain cases have significant advantage over conventionalsuch. The results of this work have been successfully applied to lexicographic optimizationin a fluence map optimization setting. / Vid optimering av behandlingsplaner i intensitetsmodulerad strålterapi används dosvolym- histogram-funktioner (DVH-funktioner) ofta som målfunktioner för att minimera avståndet till dos-volymkriterier. Varken DVH-funktioner eller dos-volymkriterier är emellertid idealiska för gradientbaserad optimering då de förstnämnda inte är kontinuerligt deriverbara och de sistnämnda är diskontinuerliga funktioner av dos, samtidigt som båda också är ickekonvexa. Speciellt fungerar DVH-funktioner ofta dåligt i bivillkor då de är identiskt noll i tillåtna områden och har försvinnande gradienter på randen till tillåtenhet. I detta arbete presenteras ett generellt matematiskt ramverk som möjliggör direkt optimering på samtliga DVH-baserade mått. Genom att betrakta voxeldoser som stickprovsutfall från en stokastisk hjälpvariabel och använda ickeparametrisk densitetsskattning för att få explicita formler, kan måtten volume-at-dose och dose-at-volume formuleras som oändligt deriverbara funktioner av dos. Detta utökas till DVH-funktioner och så kallade volymbaserade DVH-funktioner, såväl som till mindos- och maxdosfunktioner och medelsvansdos-funktioner. Explicita uttryck för evaluering av funktionsvärden och tillhörande gradienter presenteras. Det föreslagna ramverket har fördelarna av att bero på endast en mjukhetsparameter, av att approximationsfelen till konventionella motsvarigheter är försumbara i praktiska sammanhang, och av en allmän konsistens mellan härledda funktioner. Numeriska tester genomförda i illustrativt syfte visar att slät dose-at-volume fungerar bättre än kvadratiska straff i bivillkor och att släta DVH-funktioner i vissa fall har betydlig fördel över konventionella sådana. Resultaten av detta arbete har med framgång applicerats på lexikografisk optimering inom fluensoptimering.
68

Elastische Rückstoßatomspektrometrie leichter Elemente mit Subnanometer-Tiefenauflösung

Kosmata, Marcel 29 February 2012 (has links) (PDF)
In der vorliegenden Arbeit wird erstmals das QQDS-Magnetspektrometer für die höchstauflösende Ionenstrahlanalytik leichter Elemente am Helmholtz-Zentrum Dresden-Rossendorf umfassend vorgestellt. Zusätzlich werden sowohl alle auf die Analytik Einfluss nehmenden Parameter untersucht als auch Methoden und Modelle vorgestellt, wie deren Einfluss vermieden oder rechnerisch kompensiert werden kann. Die Schwerpunkte dieser Arbeit gliedern sich in fünf Bereiche. Der Erste ist der Aufbau und die Inbetriebnahme des QQDS-Magnetspektrometers, der zugehörige Streukammer mit allen Peripheriegeräten und des eigens für die höchstauflösende elastische Rückstoßanalyse entwickelten Detektors. Sowohl das umgebaute Spektrometer als auch der im Rahmen dieser Arbeit gebaute Detektor wurden speziell an experimentelle Bedingungen für die höchstauflösende Ionenstrahlanalytik leichter Elemente angepasst und erstmalig auf einen routinemäßigen Einsatz hin getestet. Der Detektor besteht aus zwei Komponenten. Zum einen befindet sich am hinteren Ende des Detektors eine Bragg-Ionisationskammer, die zur Teilchenidentifikation genutzt wird. Zum anderen dient ein Proportionalzähler, der eine Hochwiderstandsanode besitzt und direkt hinter dem Eintrittsfenster montiert ist, zur Teilchenpositionsbestimmung im Detektor. Die folgenden zwei Schwerpunkte beinhalten grundlegende Untersuchungen zur Ionen-Festkörper-Wechselwirkung. Durch die Verwendung eines Magnetspektrometers ist die Messung der Ladungszustandsverteilung der herausgestreuten Teilchen direkt nach einem binären Stoß sowohl möglich als auch für die Analyse notwendig. Aus diesem Grund werden zum einen die Ladungszustände gemessen und zum anderen mit existierenden Modellen verglichen. Außerdem wird ein eigens entwickeltes Modell vorgestellt und erstmals im Rahmen dieser Arbeit angewendet, welches den ladungszustandsabhängigen Energieverlust bei der Tiefenprofilierung berücksichtigt. Es wird gezeigt, dass ohne die Anwendung dieses Modells die Tiefenprofile nicht mit den quantitativen Messungen mittels konventioneller Ionenstrahlanalytikmethoden und mit der Dickenmessung mittels Transmissionselektronenmikroskopie übereinstimmen, und damit falsche Werte liefern würden. Der zweite für die Thematik wesentliche Aspekt der Ionen-Festkörper-Wechselwirkung, sind die Probenschäden und -modifikationen, die während einer Schwerionen-bestrahlung auftreten. Dabei wird gezeigt, dass bei den hier verwendeten Energien sowohl elektronisches Sputtern als auch elektronisch verursachtes Grenzflächendurchmischen eintreten. Das elektronische Sputtern kann durch geeignete Strahlparameter für die meisten Proben ausreichend minimiert werden. Dagegen ist der Einfluss der Grenzflächendurchmischung meist signifikant, so dass dieser analysiert und in der Auswertung berücksichtigt werden muss. Schlussfolgernd aus diesen Untersuchungen ergibt sich für die höchstauflösende Ionenstrahlanalytik leichter Elemente am Rossendorfer 5-MV Tandembeschleuniger, dass die geeignetsten Primärionen Chlor mit einer Energie von 20 MeV sind. In Einzelfällen, wie zum Beispiel der Analyse von Bor, muss die Energie jedoch auf 6,5 MeV reduziert werden, um das elektronische Sputtern bei der notwendigen Fluenz unterhalb der Nachweisgrenze zu halten. Der vierte Schwerpunkt ist die Untersuchung von sowohl qualitativen als auch quantitativen Einflüssen bestimmter Probeneigenschaften, wie beispielsweise Oberflächenrauheit, auf die Form des gemessenen Energiespektrums beziehungsweise auf das analysierte Tiefenprofil. Die Kenntnis der Rauheit einer Probe an der Oberfläche und an den Grenzflächen ist für die Analytik unabdingbar. Als Resultat der genannten Betrachtungen werden die Einflüsse von Probeneigenschaften und Ionen-Festkörper-Wechselwirkungen auf die Energie- beziehungsweise Tiefenauflösung des Gesamtsystems beschrieben, berechnet und mit der konventionellen Ionenstrahlanalytik verglichen. Die Möglichkeiten der höchstauflösenden Ionenstrahlanalytik werden zudem mit den von anderen Gruppen veröffentlichten Komplementärmethoden gegenübergestellt. Der fünfte und letzte Schwerpunkt ist die Analytik leichter Elemente in ultradünnen Schichten unter Berücksichtigung aller in dieser Arbeit vorgestellten Modelle, wie die Reduzierung des Einflusses von Strahlschäden oder die Quantifizierung der Elemente im dynamischen Ladungszustandsnichtgleichgewicht. Es wird die Tiefenprofilierung von Mehrschichtsystemen, bestehend aus SiO2-Si3N4Ox-SiO2 auf Silizium, von Ultra-Shallow-Junction Bor-Implantationsprofilen und von ultradünnen Oxidschichten, wie zum Beispiel High-k-Materialien, demonstriert. / In this thesis the QQDS magnetic spectrometer that is used for high resolution ion beam analysis (IBA) of light elements at the Helmholtz-Zentrum Dresden-Rossendorf is presented for the first time. In addition all parameters are investigated that influence the analysis. Methods and models are presented with which the effects can be minimised or calculated. There are five focal points of this thesis. The first point is the construction and commissioning of the QQDS magnetic spectrometer, the corresponding scattering chamber with all the peripherals and the detector, which is specially developed for high resolution elastic recoil detection. Both the reconstructed spectrometer and the detector were adapted to the specific experimental conditions needed for high-resolution Ion beam analysis of light elements and tested for routine practice. The detector consists of two compo-nents. At the back end of the detector a Bragg ionization chamber is mounted, which is used for the particle identification. At the front end, directly behind the entrance window a proportional counter is mounted. This proportional counter includes a high-resistance anode. Thus, the position of the particles is determined in the detector. The following two points concern fundamental studies of ion-solid interaction. By using a magnetic spectrometer the charge state distribution of the particles scattered from the sample after a binary collision is both possible and necessary for the analysis. For this reason the charge states are measured and compared with existing models. In addition, a model is developed that takes into account the charge state dependent energy loss. It is shown that without the application of this model the depth profiles do not correspond with the quantitative measurements by conventional IBA methods and with the thickness obtained by transmission electron microscopy. The second fundamental ion-solid interaction is the damage and the modification of the sample that occurs during heavy ion irradiation. It is shown that the used energies occur both electronic sputtering and electronically induced interface mixing. Electronic sputtering is minimised by using optimised beam parameters. For most samples the effect is below the detection limit for a fluence sufficient for the analysis. However, the influence of interface mixing is so strong that it has to be included in the analysis of the layers of the depth profiles. It is concluded from these studies that at the Rossendorf 5 MV tandem accelerator chlorine ions with an energy of 20 MeV deliver the best results. In some cases, such as the analysis of boron, the energy must be reduced to 6.5 MeV in order to retain the electronic sputtering below the detection limit. The fourth focus is the study of the influence of specific sample properties, such as surface roughness, on the shape of a measured energy spectra and respectively on the analysed depth profile. It is shown that knowledge of the roughness of a sample at the surface and at the interfaces for the analysis is needed. In addition, the contribution parameters limiting the depth resolution are calculated and compared with the conventional ion beam analysis. Finally, a comparison is made between the high-resolution ion beam analysis and complementary methods published by other research groups. The fifth and last focus is the analysis of light elements in ultra thin layers. All models presented in this thesis to reduce the influence of beam damage are taken into account. The dynamic non-equilibrium charge state is also included for the quantification of elements. Depth profiling of multilayer systems is demonstrated for systems consisting of SiO2-Si3N4Ox-SiO2 on silicon, boron implantation profiles for ultra shallow junctions and ultra thin oxide layers, such as used as high-k materials.
69

Elastische Rückstoßatomspektrometrie leichter Elemente mit Subnanometer-Tiefenauflösung

Kosmata, Marcel 21 December 2011 (has links)
In der vorliegenden Arbeit wird erstmals das QQDS-Magnetspektrometer für die höchstauflösende Ionenstrahlanalytik leichter Elemente am Helmholtz-Zentrum Dresden-Rossendorf umfassend vorgestellt. Zusätzlich werden sowohl alle auf die Analytik Einfluss nehmenden Parameter untersucht als auch Methoden und Modelle vorgestellt, wie deren Einfluss vermieden oder rechnerisch kompensiert werden kann. Die Schwerpunkte dieser Arbeit gliedern sich in fünf Bereiche. Der Erste ist der Aufbau und die Inbetriebnahme des QQDS-Magnetspektrometers, der zugehörige Streukammer mit allen Peripheriegeräten und des eigens für die höchstauflösende elastische Rückstoßanalyse entwickelten Detektors. Sowohl das umgebaute Spektrometer als auch der im Rahmen dieser Arbeit gebaute Detektor wurden speziell an experimentelle Bedingungen für die höchstauflösende Ionenstrahlanalytik leichter Elemente angepasst und erstmalig auf einen routinemäßigen Einsatz hin getestet. Der Detektor besteht aus zwei Komponenten. Zum einen befindet sich am hinteren Ende des Detektors eine Bragg-Ionisationskammer, die zur Teilchenidentifikation genutzt wird. Zum anderen dient ein Proportionalzähler, der eine Hochwiderstandsanode besitzt und direkt hinter dem Eintrittsfenster montiert ist, zur Teilchenpositionsbestimmung im Detektor. Die folgenden zwei Schwerpunkte beinhalten grundlegende Untersuchungen zur Ionen-Festkörper-Wechselwirkung. Durch die Verwendung eines Magnetspektrometers ist die Messung der Ladungszustandsverteilung der herausgestreuten Teilchen direkt nach einem binären Stoß sowohl möglich als auch für die Analyse notwendig. Aus diesem Grund werden zum einen die Ladungszustände gemessen und zum anderen mit existierenden Modellen verglichen. Außerdem wird ein eigens entwickeltes Modell vorgestellt und erstmals im Rahmen dieser Arbeit angewendet, welches den ladungszustandsabhängigen Energieverlust bei der Tiefenprofilierung berücksichtigt. Es wird gezeigt, dass ohne die Anwendung dieses Modells die Tiefenprofile nicht mit den quantitativen Messungen mittels konventioneller Ionenstrahlanalytikmethoden und mit der Dickenmessung mittels Transmissionselektronenmikroskopie übereinstimmen, und damit falsche Werte liefern würden. Der zweite für die Thematik wesentliche Aspekt der Ionen-Festkörper-Wechselwirkung, sind die Probenschäden und -modifikationen, die während einer Schwerionen-bestrahlung auftreten. Dabei wird gezeigt, dass bei den hier verwendeten Energien sowohl elektronisches Sputtern als auch elektronisch verursachtes Grenzflächendurchmischen eintreten. Das elektronische Sputtern kann durch geeignete Strahlparameter für die meisten Proben ausreichend minimiert werden. Dagegen ist der Einfluss der Grenzflächendurchmischung meist signifikant, so dass dieser analysiert und in der Auswertung berücksichtigt werden muss. Schlussfolgernd aus diesen Untersuchungen ergibt sich für die höchstauflösende Ionenstrahlanalytik leichter Elemente am Rossendorfer 5-MV Tandembeschleuniger, dass die geeignetsten Primärionen Chlor mit einer Energie von 20 MeV sind. In Einzelfällen, wie zum Beispiel der Analyse von Bor, muss die Energie jedoch auf 6,5 MeV reduziert werden, um das elektronische Sputtern bei der notwendigen Fluenz unterhalb der Nachweisgrenze zu halten. Der vierte Schwerpunkt ist die Untersuchung von sowohl qualitativen als auch quantitativen Einflüssen bestimmter Probeneigenschaften, wie beispielsweise Oberflächenrauheit, auf die Form des gemessenen Energiespektrums beziehungsweise auf das analysierte Tiefenprofil. Die Kenntnis der Rauheit einer Probe an der Oberfläche und an den Grenzflächen ist für die Analytik unabdingbar. Als Resultat der genannten Betrachtungen werden die Einflüsse von Probeneigenschaften und Ionen-Festkörper-Wechselwirkungen auf die Energie- beziehungsweise Tiefenauflösung des Gesamtsystems beschrieben, berechnet und mit der konventionellen Ionenstrahlanalytik verglichen. Die Möglichkeiten der höchstauflösenden Ionenstrahlanalytik werden zudem mit den von anderen Gruppen veröffentlichten Komplementärmethoden gegenübergestellt. Der fünfte und letzte Schwerpunkt ist die Analytik leichter Elemente in ultradünnen Schichten unter Berücksichtigung aller in dieser Arbeit vorgestellten Modelle, wie die Reduzierung des Einflusses von Strahlschäden oder die Quantifizierung der Elemente im dynamischen Ladungszustandsnichtgleichgewicht. Es wird die Tiefenprofilierung von Mehrschichtsystemen, bestehend aus SiO2-Si3N4Ox-SiO2 auf Silizium, von Ultra-Shallow-Junction Bor-Implantationsprofilen und von ultradünnen Oxidschichten, wie zum Beispiel High-k-Materialien, demonstriert. / In this thesis the QQDS magnetic spectrometer that is used for high resolution ion beam analysis (IBA) of light elements at the Helmholtz-Zentrum Dresden-Rossendorf is presented for the first time. In addition all parameters are investigated that influence the analysis. Methods and models are presented with which the effects can be minimised or calculated. There are five focal points of this thesis. The first point is the construction and commissioning of the QQDS magnetic spectrometer, the corresponding scattering chamber with all the peripherals and the detector, which is specially developed for high resolution elastic recoil detection. Both the reconstructed spectrometer and the detector were adapted to the specific experimental conditions needed for high-resolution Ion beam analysis of light elements and tested for routine practice. The detector consists of two compo-nents. At the back end of the detector a Bragg ionization chamber is mounted, which is used for the particle identification. At the front end, directly behind the entrance window a proportional counter is mounted. This proportional counter includes a high-resistance anode. Thus, the position of the particles is determined in the detector. The following two points concern fundamental studies of ion-solid interaction. By using a magnetic spectrometer the charge state distribution of the particles scattered from the sample after a binary collision is both possible and necessary for the analysis. For this reason the charge states are measured and compared with existing models. In addition, a model is developed that takes into account the charge state dependent energy loss. It is shown that without the application of this model the depth profiles do not correspond with the quantitative measurements by conventional IBA methods and with the thickness obtained by transmission electron microscopy. The second fundamental ion-solid interaction is the damage and the modification of the sample that occurs during heavy ion irradiation. It is shown that the used energies occur both electronic sputtering and electronically induced interface mixing. Electronic sputtering is minimised by using optimised beam parameters. For most samples the effect is below the detection limit for a fluence sufficient for the analysis. However, the influence of interface mixing is so strong that it has to be included in the analysis of the layers of the depth profiles. It is concluded from these studies that at the Rossendorf 5 MV tandem accelerator chlorine ions with an energy of 20 MeV deliver the best results. In some cases, such as the analysis of boron, the energy must be reduced to 6.5 MeV in order to retain the electronic sputtering below the detection limit. The fourth focus is the study of the influence of specific sample properties, such as surface roughness, on the shape of a measured energy spectra and respectively on the analysed depth profile. It is shown that knowledge of the roughness of a sample at the surface and at the interfaces for the analysis is needed. In addition, the contribution parameters limiting the depth resolution are calculated and compared with the conventional ion beam analysis. Finally, a comparison is made between the high-resolution ion beam analysis and complementary methods published by other research groups. The fifth and last focus is the analysis of light elements in ultra thin layers. All models presented in this thesis to reduce the influence of beam damage are taken into account. The dynamic non-equilibrium charge state is also included for the quantification of elements. Depth profiling of multilayer systems is demonstrated for systems consisting of SiO2-Si3N4Ox-SiO2 on silicon, boron implantation profiles for ultra shallow junctions and ultra thin oxide layers, such as used as high-k materials.

Page generated in 0.026 seconds