• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 328
  • 180
  • 72
  • 48
  • 21
  • 14
  • 13
  • 13
  • 9
  • 9
  • 6
  • 5
  • 5
  • 5
  • 5
  • Tagged with
  • 826
  • 168
  • 151
  • 109
  • 75
  • 66
  • 65
  • 56
  • 54
  • 48
  • 44
  • 44
  • 43
  • 41
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
521

Comparação biomecânica entre CRIF e placa de reconstrução utilizadas para estabilização de fraturas distais de fêmur de cães / Biomechanical comparison of CRIF and reconstruction plate for stabilization of distal femur fractures in dogs

Fernanda Paes 25 October 2016 (has links)
O presente estudo objetivou comparar biomecanicamente, por meio do ensaio de compressão excêntrica, a resistência dos implantes Clamp and Rod Internal Fixation (CRIF) 5,0 mm versus placa de reconstrução 3,5 mm na fixação de fratura distais de fêmur de cão. Tais implantes foram subdividos em dois grupos, denominados grupo CRIF (GC) e grupo placa (GC). Foram utilizados 22 fêmures de 10 cadáveres de cão entre 2 e 7 anos de idade e peso corporal entre 20 e 40 kg, que foram distribuídos aleatoriamente a serem testados ambos os implantes em cada um dos membros dos pares. Para realização dos testes, foi simulado uma fratura distal nos corpos de prova, através de uma osteotomia de até 0,5 cm, realizada por meio de serra oscilatória, imediatamente proximal ao início da tróclea. Os implantes foram fixados segundo os padrões AOSIF, lateralmente ao fêmur, sendo utilizados três parafusos distais e cinco proximais ao foco de fratura. Foi utilizado o programa de computador PMI para calcular o ponto máximo de resistência antes da falha e avaliadas as variáveis força máxima, deformação máxima real, rigidez, força intermediária e deformação intermediária real. Não foram encontradas diferenças estatisticamente significativas entre os GC e GP quantos as variáveis avaliadas / This study aims to compare the biomechanical properties, through eccentric compression test, of the resistance of the 5.0 mm Clamp and Rod Internal Fixation Implants (CRIF) and 3.5 mm reconstruction plate in fixing dog femur distal fracture. Such implants were subdivided into two groups, called CRIF Group (CG) and plate group (CG). It was used 22 femurs from 11 dog cadavers with age between 2 and 7 years old and body weight between 20 and 40 kg, which was randomly assigned to test both implants in each member of the pair. A distal fracture in the specimens with a gap of 0.5 cm osteotomy, it was simulated to perform the test, performed by the oscillating saw, just proximal to the beginning of the trochlea. Bound the distance from the gap to the distal femur limit was equivalent to the distance between the femoral condyles. The implants were fixed by the standards AO / SIF, laterally to the femur, being used three distal screws and five proximal to the fracture site. The bone was placed longitudinally, and the femoral neck coupled to a concave surface simulating an acetabular device. PMI computer program was used to calculate the maximum point of resistance before failure and evaluated the variables maximum strength, real maximum deformation, stiffness, intermediate strength and real intermediate deformation. No statistically significant differences were found between the GC and GP as the variables evaluated
522

Incidência de osteoporose e prevalência de fraturas referidas por idosos do Município de São Paulo. Estudo SABE: Saúde, Bem-estar e Envelhecimento, 2000 e 2006 / Incidence of self-reported osteoporosis and prevalence of self-reported fractures after 60 year-old in the elderly of São Paulo. SABE Study (Health, wellbeing and aging) 2000 and 2006

Marianella Anzola Lujan 22 November 2011 (has links)
Introdução: A osteoporose (OP) é doença caracterizada pela fragilidade do osso e, consequentemente, pelo incremento do risco de fraturas. É considerada problema de saúde pública na maioria dos países. Evidências epidemiológicas apontam associação entre variáveis sociodemográficas, variáveis de estilo de vida (como a ingestão de alimentos e de bebidas alcoólicas e hábito de fumar), e indicadores antropométricos (como índice de massa corporal -IMC-) e risco de OP e fraturas osteoporóticas. Objetivo: Estimar a incidência de OP e a prevalência de fraturas referidas, em idosos domiciliados no Município de São Paulo e verificar associação com variáveis sociodemográficas, de estilo de vida, e IMC. Método: analisaram-se dados do Estudo SABE (Saúde, Bem-estar e Envelhecimento) 2000 - 2006, o qual é estudo epidemiológico, longitudinal, de base domiciliar, cuja amostra inicial foi composta por 2143 idosos (&#8805;60 anos), de ambos os sexos, residentes habituais de domicílios urbanos no Município de São Paulo, e selecionados por amostragem probabilística, sendo que 829 idosos (39%) constituíram a amostra de estudo, em 2000, para análise da incidência de OP referida, em 2006, e 1072 idosos (50%) foi a amostra de estudo para análise de prevalência de fraturas após 60 anos referidas, em 2006. Investigou-se a associação entre variáveis sociodemográficas (sexo, grupo etário, vida no campo por 5 anos ou mais durante a infância ou adolescência, escolaridade e etnia), de estilo de vida (ingestão referida de leite e produtos lácteos, ovos e leguminosas, carnes, peixes e aves, frutas e verduras, frequência de ingestão de bebidas alcoólicas, e hábito de fumar); e variável antropométrica (IMC), com relação à referência de OP e fraturas após 60 anos, em 2006. Para verificar associação entre as variáveis categóricas e o desfecho, utilizou-se o teste de Rao & Scott (p<0,05) e a análise de regressão logística univariada (IC95%).O programa Stata, versão 10.1 foi usado para realizar os cálculos estatísticos. Resultados: Houve 114 casos novos de OP referida em 2006, sendo que o coeficiente de incidência (CI) de OP referida foi estimado em 13,93/1000 pessoas-ano (IC95%=11,60 16,87). O CI de OP referida em mulheres foi 22,95/1000 pessoas-ano (IC95%: 19,08 27,87), e 3,34/1000 pessoas-ano (IC95%: 1,85 6,73), em homens.A prevalência de fraturas após os 60 anos referidas foi 17,16%. Sexo feminino (OR= 7,69; p=0,000) e ingestão referida de bebidas alcoólicas < 4 vezes/semana (OR= 2,26; p=0,019), foram fatores de risco para referência de OP. Sexo feminino (OR=2,38;p=0,000), idade avançada (&#8805;75 anos)(OR=1,72; p=0,012), ingestão referida de bebidas alcoólicas < 4 vezes/semana (OR=2,45; p=0,016), referência de OP em 2000 (OR=1,75; p=0,048), e referência de OP em 2006 (OR=2,29; p=0,000), foram fatores de risco para referência de fraturas após 60 anos. Conclusões: sexo feminino, idade avançada foram fatores de risco para OP e fraturas após os 60 anos. Dentre as variáveis modificáveis, a ingestão de bebida alcoólica com frequência &#8805; 4 vezes/semana, esteve negativamente associado à referência de OP e fraturas após 60 anos. / Introduction: Osteoporosis (OP) is a disease characterized by bone fragility and increased risk of fractures. It is considered a public health problem worldwide. Epidemiological studies have found association between sociodemographic, lifestyle and anthropometrical variables and increased risk of OP and osteoporotic fractures. Objetive: To estimate incidence of self-reported OP, in 2006, and prevalence of fractures after the age of 60 year-old, on a sample of elderly individuals from the Município de São Paulo, and verify association between selected variables and outcome. Method: based on data from the SABE Study (health, well-being and aging) 2000 - 2006, which is an epidemiological prospective study of a probabilistic household sample of elderly population ((&#8805; 66 y), of both sexes, from São Paulo City, Brazil. Association between sociodemographic (sex, age, life in rural area for 5 year or more during childhood or adolescence, schooling, and race) lifestyle (reported food intake (milk and dairy products, eggs and legumes, meat, fish and poultry, fruit and vegetables), reported alcoholic beverages intake) and smoking habit; and anthropometrics\' variables, such as body mass index (BMI) and self-reported OP and fractures after the age of 60 year-old, in 2006. Rao & Scott Test was used to verify association between the categorical variables and outcome (p<0,05) as well as simple logistic regression (CI95%). Stata software, version 10.1, was used for statistical calculation. Results: There were 114 new cases of self-reported OP in 2006, and an incidence rate of 13,93/1000 persons-year (IC95%=11,60 - 16,87). In women the incidence rate was 22,95/1000 persons-year (CI95%: 19,08 - 27,87), and in men it was 3,34/1000 persons-year (IC95%: 1,85 - 6,73). Prevalence of self reported fractures after de age of 60 y was estimated in 17,16%. Female sex (OR= 7,69; p=0,000) and frequency of reported alcoholic beverages intake < 4 times/week (OR= 2,26; p=0,019), were risk factors for self-reported OP. Female sex (OR=2,38;p=0,000), advanced age (&#8805;75 y) (OR=1,72; p=0,012), frequency of reported alcoholic beverages intake < 4 times/week (OR=2,45; p=0,016), self-reported OP in 2000 (OR=1,75; p=0,048), and self-reported OP in 2006 (OR=2,29; p=0,000), were risk factors for reporting fractures after the age of 60 years-old Conclusions: female sex, advanced age, were risk factors for reported OP and fractures after 60 y. Among modifiable variables, intake of alcoholic beverages as often as > 4 times/week was negatively associated with reported OP and fractures after the age of 60 y.
523

"Avaliação do risco potencial de lesão do nervo facial nas vias de acesso pré-auricular e submandibular no tratamento cirúrgico das fraturas do processo condilar da mandíbula" / "Assessment of hte potential risk of lesion of the facial nerve during peauricular and submandibular approaches to the surgical treatment for mandibular condylar process fractures"

Flavio Francisco de Godoy Peres 16 December 2002 (has links)
RESUMO O nervo facial é uma importante preocupação para o cirurgião durante o acesso à cabeça da mandíbula, quando o tratamento cirúrgico é escolhido. As duas vias mais freqüentemente utilizadas, a pré-auricular e submandibular possuem uma relação anatômica direta com seu ramo temporal e marginal da mandíbula, respectivamente. Tanto o desconhecimento de possíveis variações na sua distribuição anatômica do nervo facial como os elementos fundamentais da técnica cirúrgica influenciam o risco de seqüela pós-operatória. Para a via de acesso pré-auricular, há uma definida posição imediatamente pré-auricular junto à cartilagem do trágus, a incisão relaxante é apontada por alguns autores como manobra preventiva de seqüelas como o lagoftalmo (incapacidade da oclusão palpebral). O plano único profundo à fáscia temporoparietal (na fossa temporal), ao periósteo do arco zigomático, e à fáscia parotideomassetérica geram um retalho que parece proteger os ramos que cruzam o mencionado arco. No que tange à via de acesso submandibular, o ângulo e a base da mandíbula bem como os vasos faciais (artéria e veia faciais) são referenciais anatômicos consagrados na literatura. Entretanto, a mesma literatura aponta para uma freqüente pluricidade na ramificação do clássico nervo marginal da mandíbula, ramo do nervo facial, em uma situação subplatismal a uma distância variável da base da mandíbula. A não identificação do nervo pode acarretar diferentes graus de seqüela labial pela lesão nervosa por compressão ou estiramento mecânicos, queimaduras nervosas na eletrocoagulação imprecisa e tempestiva de vasos adjacentes, ressecção nervosa com a conseqüente paresia transitória ou ainda a paralisia permanente da musculatura do lábio inferior do lado afetado. Lesão térmica ou mecânica devem ser prevenidos durante as manobras hemostasia e sínteses. Para tanto, o mapeamento intra-operatório pré-incisional (paciente sob anestesia geral) de modo ainda bastante incipiente parece ser uma ferramenta promissora na localização precisa de modo a orientar profilaticamente a incisão inicial. / SUMMARY The facial nerve is an important surgeon concern while approaching the mandibular condylar process in the fracture surgical treatment. The preauricular and submandibular pathways are the two most frequently used approaches, which have a direct relation to the temporalis and marginalis mandibulae branches of the facial nerve, respectively. The lack of knowledge over possible variations on their anatomical distribution and mastery of the fundamental elements on surgical technique jeopardize the patient to the postoperative sequels. About the preauricular approach, there is a well-established tragus anterior incision. Some authors point out a continuous relaxing incision as a preventive maneuver to avoid lagophtalmus, for instance. The opening of an unique plane formed by the profound face of the temporoparietal fascia in the temporal region, deep face of periostheum over zygomatic arch and parotideomasseteric fascia as well generates a protective flap which includes facial nerve branches that cross up-and-forwardly the zygomatic arch. In regards to the submandibular approach, the angle and lower border of the mandible as well facial vessels are scientific well-known anatomic landmarks to place the initial incision, preventing the facial nerve from lesion. Nevertheless, recent scientific publications point out some frequent multiple branching patterns in the marginalis mandibulae, a facial nerve branch, always underneath platysm muscle in a variable caudad distance from lower border of the mandible. The lack of identification of the nerve may lead to different degrees of lower lid sequel by compression or strechening strengths, electric burns during imprecise adjacent bleeding vessels electric coagulation maneuver, or even a complete nerve transection responsible for a permanent paralysis of the lower lid. Thermal or mechanical injury should be avoided during haemostatic and synthesis maneuvers. The intra-operative pre-incisional mapping of the facial nerve (patient under general anesthesia), a very new method already on experimentation seems to be a promising tool in the nerve localization in the way to guide the surgeon before initial incision.
524

Decanoato de nandrolona, qualidade óssea e calo ósseo em fratura do fêmur de rato / Nandrolone decanoate, bone quality and bone callus in rat femur fracture

Ana Paula Franttini Garcia Moreno Guimarães 24 August 2017 (has links)
Tem havido grande interesse na investigação de substâncias de ação sistêmica que atuam sobre o sistema musculoesquelético, no sentido de melhorar a qualidade óssea e muscular, e assim, evitar fraturas patológicas decorrentes de osteoporose. Os esteroides anabólicos androgênicos têm importante atuação no metabolismo sistêmico geral, sendo que no osso aumenta sua resistência, massa e, no músculo, combate a sarcopenia. Entretanto, não há investigações consistentes sobre a possível atuação dessas substâncias na consolidação óssea. Este estudo teve como objetivo avaliar o efeito do decanoato de nandrolona na consolidação óssea e na qualidade óssea de fêmures de ratos machos adultos jovens da linhagem Wistar. Foram utilizados 112 animais, divididos em 04 grupos com 02 subgrupos (14 e 28 dias). Um grupo controle (n=17) foi formado por animais sem intervenção, mas apenas com a injeção de veículo inerte. Em outro grupo foi provocada fratura da diáfise do fêmur (n=26). No terceiro grupo os animais receberam apenas decanoato de nandronola (n=23). No quarto grupo foi provocada fratura na diáfise do fêmur associada à administração da mesma dosagem de decanoato de nandrolona (n=26). A fratura provocada no fêmur foi pelo método fechado e obtida com auxílio de uma guilhotina com lâmina romba. Em seguida, a fratura foi fixada por um fio de Kirschner de 1,0 mm de espessura, inserido no canal medular, e o membro pélvico foi radiografado em perfil. O decanoato de nandrolona foi aplicado na dose de 10 mg/kg de massa corporal, por via intramuscular, 02 vezes por semana, durante 14 ou 28 dias, conforme o subgrupo. Após a eutanásia os fêmures direitos foram dissecados e tiveram o comprimento medido. A densidade mineral óssea e o conteúdo mineral ósseo foram determinados pelo método da absorciometria de raios X de dupla energia (DXA). A resistência óssea foi determinada pelo ensaio mecânico de flexão em dois pontos, com o cálculo com a da força máxima e rigidez. O calo ósseo foi avaliado microscopicamente em cortes histológicos corados pela hematoxilina e eosina e examinados em luz comum para a obtenção do seu volume por técnica morfométrica. As outras secções foram coradas em picrosirius red e examinadas em luz polarizada para a quantificação do colágeno tipo I. A significância estatística foi estabelecida em 5%. Não houve diferença significante entre os animais tratados e não tratados pelo decanoato de nandrolona quanto à densidade mineral óssea, conteúdo mineral ósseo, resistência mecânica, tanto para o osso sem fratura, quanto para o calo ósseo. A quantidade de colágeno tipo I também não foi diferente, entretanto, o volume de osso neoformado nos grupos que receberam o esteroide anabolizante foi significantemente maior. A massa corporal foi maior nos grupos que receberam decanoato de nandrolona, embora sem significância estatística. O comprimento ósseo foi maior aos 28 dias no grupo tratado com decanoato de nandrolona. A massa do calo também teve valor significativamente maior aos 28 dias nos animais que receberam o decanoato de nandrolona. Com base nos resultados encontrados, sob as condições experimentais e métodos de avaliação empregados, o decanoato de nandrolona não causou efeitos significativos benéficos ou maléficos, tanto na qualidade do calo ósseo, como na qualidade do osso normal íntegro do rato adulto jovem. / There has been a great interest in investigating systemic substances that can positively act on the musculoskeletal system to improve the bone quality thus avoiding osteoporotic fractures. The anabolic androgenic steroids have an important influence on general metabolism and can increase the bone resistance and bone mass. On muscle, it improves sarcopenic conditions. However, there is no consistent investigation of a possible action of these substances on bone callus. Thus, the aim of this study was to evaluate the effect of decanoate of nandrolone on fracture healing and bone quality of young adult male Wistar rats. One hundred animals were divided into 04 groups and 02 subgroups (14 and 28 days). A control group consisted of animals without any intervention (n=17). In the second group, a femoral shaft fracture was performed (n=26). In the third group, the animals received only decanoate of nandronole (n=23). In the fourth group, a fracture in the femoral shaft was performed and associated with administration of the same dose of decanoate of nandrolone (n=26). The fracture created in the femur was obtained by closed method and achieved with the aid of a blunt blade guillotine. After that, the fracture was fixed with a 1.0 mm thick Kirschner wire that was inserted into the medullary canal, and the limb was X-rayed in profile. Ten mg/kg of body mass of decanoate of nandrolone was administered intramuscularly, 02 times a week for 14 or 28 days, depending on the subgroup. After euthanasia, the right femurs were dissected and had the length measured. Bone mineral density and bone mineral content were determined by the dual-energy x-ray absorptiometry method (DXA). The mechanical properties maximum force and stiffness were determined by the twopoint bending test. The bone callus was evaluated microscopically in sections stained with hematoxylin and eosin and examined under ordinary light microscope to calculate the volume of bone callus by the morphometric technique. Other sections were stained in picrosirius red and examined under polarized light for quantification of type I collagen. The statistical significance was set at 5%. There was no significant difference between the animals treated and not treated with nandrolone decanoate for bone mass density, bone mineral content, mechanical resistance and type I collagen, both for the intact bone and for the bone callus. However, the body mass was higher in the groups that received nandrolone decanoate, although without statistical significance. The femur length was greater in the 28th day in the group treated with nandrolone decanoate. Callus mass also had significant increase at 28 days for animals that received nandrolone decanoate. Based on the results and under the experimental conditions and methods of evaluation, the decanoate of nandrolone did not cause significant benefit or harmfull effects both on callus and on bone qualities.
525

Aperfeiçoamento do método de elementos analíticos para simulação de escoamento em rochas porosas fraturadas / Improvement of the analytical element method for simulating of flow in fractured porous rocks

Ivan Silvestre Paganini Marin 07 October 2011 (has links)
Escoamento de água subterrânea em meios porosos fraturados é um problema de grande importância, principalmente nos contextos de petróleo, energia geotérmica e repositórios geológicos. Com o aquecimento da Terra, a geração de energia com baixa emissão de gases estufa torna-se imperativa, considerando o crescimento de uso de energia e o impacto do aquecimento global. Dentre as opções disponíveis para geração de energia, a energia nuclear apresenta-se como candidata. Entretanto, dentre os riscos do uso de energia nuclear, o destino do combustível usado e de materiais provenientes de descomissionamento é um problema em aberto. Repositórios geológicos surgem como uma alternativa para a estocagem de médio e longo prazo, por serem capazes de proporcionar isolamento em escalas geológicas de tempo. O principal vetor de propagação do material radioativo estocados em repositórios é a água subterrânea, e meios fraturados estão presentes na maioria dos domínios. Fraturas podem propagar a água subterrânea e, portanto, solutos com velocidades muito maiores que as do meio poroso. Além disso, fraturas são, geralmente, sistemas multiescala, em que diferentes escalas - de centímetros a kilômetros - podem ter um papel significativo. Métodos como elementos finitos, apesar de representarem certos comportamentos do escoamento em fraturas, têm dificuldade em simular sistemas com grandes diferenças de escala, já que necessitam de discretização do domínio. O Método de Elementos Analíticos (MEA) surge como uma alternativa a esse problema, pois não necessita de discretização de domínio, podendo simular características hidrogeológicas em diferentes escalas. Este trabalho tem como proposta aperfeiçoar o MEA, desenvolvendo um elemento analítico para fraturas que interagem com o meio poroso, aplicando os desenvolvimentos recentes na teoria do Método. Baseado na Integral de Cauchy e em transformações de coordenadas, o novo formalismo de solução no plano permite maior precisão na imposição das condições de contorno, sendo aplicado para inomogeneidades circulares, inomogeneidades poligonais formadas por line doublets e para o elemento de fratura. Dificuldades numéricas na simulação para fraturas levaram ao desenvolvimento de um método matricial de solução, aplicado com sucesso para todos os elementos apresentados neste trabalho. Soluções exatas para a inomogeneidade circular e para uma fratura foram comparadas com inomogeneidades poligonais equivalentes, com sucesso. O método matricial permitiu também um estudo da convergência do método iterativo e possibilita a melhoria do Método de Elementos Analíticos em geral. / Groundwater flow in fractured porous media is a recent and modern problem, considering the petroil, geothermic energy and geologic repositories context. As the Earth warms, low \'CO IND.2\' energy generation is paramount, when the projections of energy demand and worsening of the global warming effects are factored in. Nuclear energy generation appears as one of the canditates to generate electricity with low \'CO IND.2\' emissions. Several factors must be considered, thought, when nuclear energy is concerned. The spent nuclear fueld and the decomission residues must be safely stored for long periods of time. One of the alternatives for mid and long term disposal is the use of geological repositories. Because of its characteristics, groundwater studies must be conducted to assert the safety of the repositories, as its the main contaminant vector for the stored nuclear material. Fractures must be considered in those studies, as they are usually present in almost all settings considered for repositories, and can propagate groundwater (and dissolved solutes) with very high speeds, several orders of magnitude faster than the porous media. Fractures also forms multiscale problems, where different problem scales - from centimeters to kilometers - can influence the behavior of the groundwater flow and the consequent solute transport. The usual groundwater simulation methods, even when capable of including fracture phenomena, have problems with the scale differences, as they usually depend on domain discretization. The Analytic Element Method is based on analytic solutions of the groundwater governing equations and does not depend on domain discretization, being able to tackle multiscale problems that the other methods cant produce a feasible solution. The Analytic Element Method has been developed in recent years and has been applied in different fields, as wellhead protection area delineation. This work proposes to improve the Analytic Elemento Method developing an analytic element for flow in fractures, using the recent developments as the direct use of Cauchy Integrals in the plane. These new developments allow increased precision on the numerical boundary conditions matching. This method is applied on circular inhomogeneities, polygonal inhomogeneities modelled by line doublets and the fracture element. Numerical problems in the boundary condition matching for the fractures led to the development of matrix solution method, used on all elements presented in this work. Exact solutions for one circular inhomogeneity and for one fracture allowed comparison with the numerical ones, with satisfactory results. The matrix method also permitted a convergence study of the iterative methods, possibilitating for the general improvement of the Analytic Element Method.
526

Efeitos do ultra-som de baixa intensidade sobre a consolidação óssea em fraturas de ossos longos (rádio e ulna, fêmur, tíbia e fíbula) em cães (Canis familiaris) / Low-intensity ultrasound effects on the healing of long bone fractures (radius and ulna, femur, tibia and fibula) in dogs (Canis familiaris)

Valéria Lima de Sousa 13 August 2003 (has links)
Este trabalho teve como objetivo realizar a investigação clínica dos efeitos do ultra-som de baixa intensidade como tratamento adjuvante na consolidação óssea de fraturas de ossos longos (rádio e ulna, fêmur, tíbia e fíbula) em cães. Foram utilizados 29 cães de raças variadas, 17 fêmeas e 12 machos, com faixa etária entre seis e 72 meses, 2,3 a 43 kg de peso corporal, portadores de fraturas recentes em ossos longos (rádio e ulna, fêmur, tíbia e fíbula), submetidos a procedimentos de osteossíntese (pinos intramedulares, fixação esquelética externa ou a associação destes métodos) e provenientes da rotina hospitalar de três instituições. Um dos cães apresentou fratura bilateral de tíbia e fíbula, tendo sido consideradas 30 fraturas. Os animais foram divididos em três grupos, de acordo com o local da fratura: GI (rádio e ulna), GII (fêmur), e GIII (tíbia e fíbula). Realizou-se o tratamento adjuvante de fraturas com ultra-som pulsado de baixa intensidade (30 mW/cm2 , durante 20 minutos, por 21 dias consecutivos) em 12 cães e 17 animais foram utilizados como controle. Todos os pacientes foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e aos 30 e 60 dias posteriores ao procedimento cirúrgico. Nos exames radiográficos foram observadas características de consolidação óssea, incluindo a presença ou ausência de reação periostal, ponte cortical, linha de fratura e formação de calo ósseo. O teste estatístico não paramétrico bilateral de Mann-Whitney foi empregado para a análise dos resultados dos achados radiográficos constatados nos animais dos grupos controle e tratado, não tendo sido verificadas diferenças significativas entre eles. Apesar da ausência de comprovação estatística, a maioria das fraturas tratadas com estimulação ultra-sônica demonstrou sinais clínicos e radiográficos de evolução favorável ao processo de consolidação óssea. Conforme os resultados observados neste estudo, o ultra-som pulsado de baixa intensidade pode ser indicado como tratamento adjuvante de fraturas recentes de ossos longos (rádio e ulna, fêmur, tíbia e fíbula), em animais da espécie canina. / This research had the purpose of investigating the clinical effects of low-intensity ultrasound on the healing of long bone fractures (radius and ulna, femur, tibia and fibula) in dogs. Twenty-nine dogs of different breeds were included in this study, being 17 females and 12 males, with ages ranging from six to 72 months, and weight from 2.3 to 43 kg. These animals presented a clinical history of recent long bone fractures (radius and ulna, femur, tibia and fibula), and underwent osteosynthesis procedures (intramedullary pins, external skeletal fixation or the association of both). All of the animals originated from three different veterinary hospitals. One of the dogs presented bilateral tibial fracture, encompassing a total of 30 fractures in such group. The animals were divided into three groups, according to the fracture site: GI; (radius and ulna), GII (femur), and GIII (tibia and fibula). The treatment with pulsed low-intensity ultrasound (30 mW/cm2 , for 20 minutes, for 21 consecutive days) was performed on 12 dogs, using 17 animals as a control group. All patients were evaluated through physical and radiographic examination before surgery, immediately on the postoperative, and after 30 and 60 days from the osteosynthesis. Postoperative and follow-up radiographs were examined for periosteal reaction, cortical bridging, fracture line and callus. The non-parametric bilateral Mann-Whitney Test was used to investigate the radiographic findings in the group undergoing treatment and in the control group. There were no significant statistical differences between them. In spite of these statistical results, most of the fractures treated with pulsed low-intensity ultrasound showed clinical and radiographic signs of bone healing in progress. According to these results, pulsed low-intensity ultrasound can be indicated as an adjunctive treatment for recent long bone fractures (radius and ulna, femur, tibia and fibula) in dogs.
527

Avaliação radiográfica, histomorfométrica e de função de vôo após fixação de osteotomias distais de úmero em pombas (Columba livia), com modelo inédito de fixador externo articulado. Estudo comparativo de fixador transarticular dinâmico e estático / Radiographic histomorphometric and of flight function evaluations after distal humeral osteotomies in pigeons (Columba livia), with inedit articulated external fixator. Comparative study of dynamic and static transarticular fixators

Vanessa Couto de Magalhães Ferraz 26 September 2008 (has links)
O tratamento de fraturas umerais distais em aves impõe grande dificuldade, devido a córtices muito finas dos ossos A artrodese com fixador externo da articulação úmero-rádio-ulnar é inviável para aves que se pretende reintroduzir ao meio ambiente. Doze animais foram divididos em dois grupos: cirurgias bilaterais com anquilose de uma asa (asa estática) e manutenção da articulação da outra (asa dinâmica) (grupo 1), e cirurgia unilateral, com manutenção da função da articulação (asa dinâmica), sendo a outra controle (asa intacta) (grupo 2). Foram feitas avaliações clínicas, radiológicas, morfológicas do osso, histomorfométricas (de ambos os grupos) e de capacidade de vôo (grupo 2). A 6 semanas, todos os animais apresentavam fraturas consolidadas, com excessão de dois animais do grupo 1, que somente apresentaram consolidação das asas dinâmicas às 9 semanas e das estáticas às 12 semanas. Todos os animais do grupo 2 apresentaram capacidade de vôo adequada, antes de 13 semanas após a cirurgia. No grupo 1 o úmero da asa dinâmica representava 99,1% do comprimento do da asa estática, e no grupo 2, estes eram 99,5% em relação à asa intacta. A amplitude da asa, no grupo 2, demonstrou que a relação da asa dinâmica/intacta foi de 93%, e no grupo 1 a relação asa dinâmica/estática foi de 105%. O volume do osso intacto foi de aproximadamente 29% da área estudada, enquanto o da asa estática foi de 19% e das asas dinâmicas, de 22%. Houve diferença entre o número de osteoblástos das asas intactas e dinâmicas, porém não houve diferença entre as asas estáticas e intactas e entre as dinâmicas e as estáticas, e também não houve diferença do número de osteoclástos entre nenhum tipo de asa. A razão da superfície óssea pelo volume ósseo indica a quantidade de áreas de reabsorção. Não houve diferença entre as asas estática e dinâmica, porém houve diferença entre estas e os controles. O método proposto de técnica para fixação de fraturas umerais distais, sem a anquilose da articulação úmero-rádio-ulnar, demonstrou ser efetivo em manter o comprimento ósseo, a amplitude da asa e assim, garantindo a capacidade de vôo das aves tratadas, além de demonstrar ser equivalente histológicamente à técnica tradicional e mais estável de anquilose da articulação, para este tipo de fratura, e até mesmo, no período estudado, ser equivalente ao osso são, sendo um método adequado para a reparação de fraturas distais de úmero em aves quando se pretende a reabilitação destes animais. / The treatment of humeral distal fractures in birds is very difficult, because these bones are very brittle. Ankylosis of the humeral-radio-ulnar joint with an external fixator is unviable for birds intended for re-habilitation and reintroduction. Twelve animals were used and they were divided in two groups: bilateral surgeries, with ankylosis of one wing (static wing) and maintenance of the joint function of the other wing (dynamic wing) (group 1), and unilateral surgery, with maintenance of the joint function of the wing (dynamic wing), and the other was used as control group (intact wing) (group 2). Clinical, radiographic, morphologic and histomorphometric evaluations of the wings and bones (of both groups) and of evaluations of flight capacity (in group 2) were made. At 6 weeks, all animals had healed fractures, except two animals in group 1, that only presented consolidation of the dynamic wing at 9 weeks and the static wings at 12 weeks. All animals in group 2 were capable of flying before 13 weeks after surgery. In group 1, the humerus of the dynamic wing was 99.1% the length of that of the static wing, and in group 2, these were 99.5% compared to the intact wing. Wing amplitude, in group 2, showed a dynamic/ intact ratio of 93%, and in group 1 the dynamic/ static wing ratio was 105%. The volume of the intact bone was approximately 29% of the studied area, while in the static wing it was of 19% and in the dynamic wing, 22%. There was a difference in the number of osteoblasts of the intact and dynamic wings, but there was no difference between static and intact, and between dynamic and static wings, and also, there was no difference in the numbers of osteoclasts between any wings. The bone surface/ volume ratio indicates the amount of resorption areas. There was no significant difference between static and dynamic wings, but there was a difference between static and intact wings. The proposed method of distal humeral fracture fixation technique, without ankylosis of the humerus-radius-ulna joint, demonstrated being effective in keeping bone length, wing amplitude e therefore, guaranteeing flight capacity of the birds treated, as well as being histologically equivalent to the tradicional, more stable, joint ankylosis technique, for thise kind of fracture, and even, for the studied period, being equivalent to healthy bone, being an adequate method for fracture repair for this kind of fracture in birds, when one intends rehabilitation of these animals.
528

Estudo mecânico &quot;in vitro&quot; da resistência a forças axiais do parafuso canulado de 3,5mm de diâmetro, em comparação ao parafuso convencional de mesmo diâmetro, em fraturas de cabeça e colo femoral / Mechanical study &quot;in vitro&quot; of the resistance of axial forces of 3.5mm cannulated screws in comparison with conventional screws of the same diameter, in head and femoral neck fractures

Daniel Castelo Branco Baccarin 28 June 2006 (has links)
Em razão da complexidade da osteossíntese nas regiões de colo e cabeça femorais, aliado à dificuldade da boa redução e fixação da fratura, objetivou-se estudar comparativamente os efeitos das cargas com forças axiais nos conjuntos osso-parafuso convencional e osso-parafuso canulado. O parafuso canulado possui eficiente capacidade compressiva e por possuir uma cânula central é capaz de simplificar a técnica cirúrgica se comparado aos parafusos ósseos convencionais. Foram utilizados dois parafusos dispostos paralelamente, inseridos da porção lateral do fêmur, abaixo do trocânter maior, em direção à cabeça femoral em 14 fêmures de cães acima de 20 kilos de peso, subdivididos em 2 grupos de 7 fêmures com parafusos convencionais e 7 fêmures com parafusos canulados , sem sinais macroscópicos ou radiográficos de moléstias ósseas. Os resultados obtidos mostraram que não houve diferenças estatísticas na força máxima e na rigidez nos dois grupos, e em todos os ensaios, os implantes não sofreram deformação, portanto conclui-se que as resistências dos parafusos convencional e canulado, utilizados na osteossíntese de fraturas de cabeça e colo de fêmur, são semelhantes. / Because of the complexity of osteosynthesis of femoral head and neck fractures and the difficulty of good reduction and fixation of the fractures, we studied comparatively the effects of load and axial forces of bone-conventional screws and bone-cannulated screws. The cannulated screw presents efficient compressive capacity and it presents a central cannula capable of simplifying the surgical technique if compared to conventional bone screws. We used two screws placed parallel, inserted in the lateral aspect of the femur, beneath the greater trocanter, directed to the femoral head, in fourteen femurs of dogs over 20Kg, subdivided in two groups of seven femurs each, the first with conventional screws and the second with cannulated screws, with no macroscopic or radiographic signs of bone diseases. The results didn´t show any statistical differences in maximum strength and rigidity of both groups and the implants didn´t suffer deformities in any essays, therefore we conclude that the resistances of conventional and cannulated screws, used in of femoral heads and necks fracture repairs, are similar.
529

Análise mecânica e fotoelástica de quatro diferentes métodos de fixação em fraturas de corpo mandibular / Mechanical and photoelastic analysis of four different fixation methods for mandibular body fractures

Rodrigues, Danillo Costa, 1981- 24 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T15:32:49Z (GMT). No. of bitstreams: 1 Rodrigues_DanilloCosta_D.pdf: 786712 bytes, checksum: 20e5c6c3c2775a5b2c547eae752381d0 (MD5) Previous issue date: 2014 / Resumo: O propósito do presente estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fotoelástica, quatro métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de poliuretano e resina fotoelástica. O trabalho foi dividido em quatro grupos: O grupo I, foi fixado com duas placas do sistema 2,0mm, uma na zona de tensão e outra na zona de compressão mandibular. No grupo II, utilizou-se uma placa do sistema 2,0mm na zona central da mandíbula e uma barra de Erich na zona dentada. O grupo III, foi fixado com uma placa do sistema 2,4mm na zona de compressão e uma barra de Erich na zona dentada. E no grupo IV, foi empregada uma placa do sistema 2,0mm na zona de tensão e uma placa do sistema 2,4mm na zona de compressão. Os métodos de fixação utilizados em cada grupo foram semelhantes em ambos os testes. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®. Os valores foram analisados pelo teste de Shapiro-Wilk. Em seguida, foi aplicada a Análise de Variância (ANOVA), Kruskal-Wallis e posteriormente, o teste de Tukey e Mann-Whitney com correção de Bonferroni. Para a análise do teste fotoelástico, as hemimandíbulas em resina fotoelástica foram fotografadas quando a máquina de ensaio registrou o deslocamento final de 3mm e as franjas formadas no substrato foram avaliadas de forma qualitativa. Os resultados dos testes mecânicos indicaram que o grupo II apresentou menor resistência, seguido dos grupos I, IV e III. O teste fotoelástico confirmou a maior formação de tensão no grupo de menor resistência mecânica. Dessa forma concluiu-se que em fraturas lineares de corpo de mandíbula a utilização de placa do sistema 2,4mm apresentou maior resistência e que o emprego de apenas uma placa do sistema 2,0mm na zona central apresentou maior tensão / Abstract: The purpose of this study was to evaluate comparatively through linear load testing and photoelastic analysis, four methods of fixation in simulated fractures on polyurethane hemimandibles body and photoelastic resin. The study was divided into four groups: Group I was fixed with two plates of 2.0 mm system, one in the tension zone and another in compression zone. In Group II, it was used a 2.0 mm plate in the neutral zone and an Erich bar. Group III was fixed with a 2.4 mm plate in the compression zone and an Erich bar. The group IV was employed a 2.0 mm plate in tension zone and a 2.4 mm plate in the compression zone. The fixation methods used in each group were similar in both tests. Linear load testing was performed using an Instron® mechanical universal testing machine. After the tests, the values were analyzed by the Shapiro-Wilk test, Analysis of Variance (ANOVA), Kruskal -Wallis test and subsequently the Tukey test, and Mann-Whitney test with Bonferroni correction. For the analysis of photoelastic test, the hemimandibles were photographed in photoelastic resin when the testing machine recorded the final displacement of 3mm and the fringes formed on the substrate were evaluated qualitatively. The results of mechanical tests indicated that the group II had lower resistance, followed by the groups I, III and IV. The photoelastic test confirmed the increased formation of tension in the group of lower mechanical strength. Thus, it was concluded that in linear mandibular body fracture using the system board 2.4 mm presented more resistance and the use of only one 2.0 mm plante in the central area of the mandible showed higher tension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
530

Detecção de fraturas radiculares verticais em radiografias convencionais e digitais obtidas em três diferentes sistemas na presença e ausência de material intracanal / Detection of vertical root fractures in conventional and digital radiography obtained in three different systems in the presence and absence of intracanal materials

Nascimento, Helena Aguiar Ribeiro do, 1986- 24 August 2018 (has links)
Orientador: Deborah Queiroz de Freitas França / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T14:50:35Z (GMT). No. of bitstreams: 1 Nascimento_HelenaAguiarRibeirodo_M.pdf: 1294865 bytes, checksum: aad6a2937765cf9381c0d31a4575d026 (MD5) Previous issue date: 2014 / Resumo: O objetivo no presente estudo foi avaliar a detecção de fraturas radiculares verticais (FRVs) em radiografias convencionais (RCs) e obtidas em três sistemas digitais com diferentes condições intracanal. Foram utilizados 40 dentes humanos unirradiculares com as coroas seccionadas na junção cemento-esmalte. Em seguida, os dentes foram divididos em dois grupos com 20 dentes em cada: grupo controle sem fratura e grupo com FRV. As FRVs foram induzidas em uma máquina de ensaio universal. Após, todos os dentes foram posicionados individualmente no alvéolo de uma secção mandíbula humana seca. Foram obtidas imagens de todos os dentes de acordo com a condição intracanal: sem preenchimento, com guta-percha, com pino metálico e com pino de fibra de vidro. As imagens foram obtidas utilizando-se a técnica do paralelismo e três incidências (orto, mésio e distorradial), com filme convencional (Kodak), placas de armazenamento de fósforo (Digora Optime® e VistaScan®) e um sensor CMOS (SnapShot®). Todas as imagens foram avaliadas por cinco examinadores em uma escala de 5 pontos. Após trinta dias, 25% da amostra foi reavaliada. As reprodutibilidades intra e interexaminador foram avaliadas por meio do Teste Kappa ponderado. Foram calculados os valores de sensibilidade, especificidade, acurácia, valores preditivos positivo e negativo. A comparação das avaliações com o padrão-ouro foi obtida utilizando a área sob a curva ROC, comparadas por meio da análise de variância dois critérios com teste post-hoc de Tukey e nível de significância de 5%. As reprodutibilidades intra e interexaminador exibiram valores de moderado a substancial. Apenas a sensibilidade apresentou diferença significante entre as modalidades de imagem, com valores superiores para o SnapShot (53,3%) e VistaScan (46,0%), seguidos pela RC (41,0%) e Digora (37,5%). Ainda o sistema SnapShot (0,82) apresentou área sob a curva ROC maior que os demais (VistaScan: 0,70; Digora: 0,64; RC: 0,68) na presença do pino de fibra de vidro. Foi possível concluir que todas as modalidades de exame apresentaram um bom desempenho no diagnóstico de FRV na ausência de material intracanal e inferior na presença do pino metálico ou guta-percha. Na condição com pino de fibra de vidro, sistemas digitais com maiores resoluções devem ser preferidos / Abstract: This study aimed to evaluate the detection of vertical root fractures (VRFs) in conventional radiography (CR) and three digital systems in teeth with different intracanal condition. The sample consisted of forty single-rooted human teeth, in which the crowns were sliced at the cementoenamel junction. Then, the teeth were divided equally in two groups: control without fracture and root fracture. The VRFs were induced through a universal testing machine. After this process, all teeth were individually placed in a dry mandible. The images were obtained of all teeth according to the intracanal condition: no filling, gutta-percha, metal and fiberglass post. The images were obtained using the parallelism technique with three different horizontal angulations (ortho, mesial and distorradial) with conventional film (CF) (Kodak), two storage phosphor plates (Digora Optime® and VistaScan®) and one CMOS sensor system (SnapShot®). All images were evaluated by five examiners on a 5-point scale. After thirty days, 25% of the images were re-evaluated. The intra and interobserver reproducibility were calculated using the weighted-kappa test. Values of sensitivity, specificity, accuracy, positive and negative predictive values were calculated. The area under the ROC curve of all modalities in the presence of different intracanal materials was calculated and compared using the two-way analysis of variance (ANOVA) with post-hoc Tukey test and a significance level of 5%. The intra- and interobserver reproducibility values ranged from moderate to substantial. Only the sensitivity showed a significant difference between imaging modalities, with higher values for SnapShot (53,3%) and VistaScan (46,0%), followed by the CR (41,0%) and Digora (37,5%). Also SnapShot (0,82) had an area under the ROC curve greater than the others in the fiberglass post group (VistaScan: 0,70; Digora: 0,64; CR: 0,68). It was concluded that all imaging modalities had a good performance in the diagnosis of VRF in the absence of intracanal materials and lower in the presence of the metal post or gutta-percha. In the fiberglass post group, digital systems with higher resolution should be used / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica

Page generated in 0.06 seconds