• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 6
  • 6
  • 6
  • 6
  • 5
  • 1
  • Tagged with
  • 58
  • 58
  • 35
  • 25
  • 23
  • 18
  • 18
  • 17
  • 16
  • 14
  • 12
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

A influência das respostas auditivas do estado estável nas respostas auditivas ao implante coclear / Auditory steady-state response influence on cochlear implant auditory response

Julia Santos Costa Chiossi 28 August 2017 (has links)
Introdução: O potencial evocado auditivo de estado estável (PEAEE) é um exame eletrofisiológico que permite a testagem simultânea e binaural do limiar auditivo por frequência específica. Por seu caráter objetivo vem sendo recomendada sua inclusão na bateria de testes para diagnóstico de crianças com deficiência auditiva. A possibilidade de diagnóstico precoce da perda de audição em crianças é fundamental para a redução dos agravos decorrentes da privação sensorial e a tomada de decisão quanto à intervenção adequada, como o uso do implante coclear (IC). A determinação do sucesso do uso do IC é dependente de múltiplos cofatores, entre eles, sugere-se que a presença de audição residual prévia ao implante poderia possibilitar a preservação das vias auditivas e áreas auditivas corticais, proporcionando melhor desenvolvimento das habilidades auditivas e de produção oral da linguagem com o reestabelecimento da entrada sensorial. Objetivo: Verificar a relação entre o PEAEE pré-operatório e a resposta auditiva pós-implante de crianças submetidas ao IC. Casuística e Método: Trata-se de um estudo observacional retrospectivo, desenvolvido a partir da análise de prontuários de pacientes do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, submetidos à cirurgia de IC. Foram incluídas 47 crianças menores de 6 anos à data de realização da cirurgia, diagnosticadas com perda auditiva neurossensorial pré-lingual de grau profundo. Foram coletadas informações audiológicas pré-implantação - PEAEE, PEATE, audiometria comportamental e demais aspectos de caracterização da perda auditiva; a categoria de percepção auditiva e de expressão oral da linguagem antes e após a implantação; além de informações socioeconômicas e da intervenção terapêutica. Resultados: O registro do PEAEE esteve presente em 34 (72,3%) crianças com limiar médio de 89,7 ± 10,2 dB NA na orelha implantada, consideradas as frequências de 0,5; 1; 2 e 4 kHz. A reavaliação foi conduzida em média 7,2 ± 2,1 meses após a cirurgia de IC, quando 23 (49%) sujeitos apresentaram avanço de uma categoria no desenvolvimento da percepção de fala e 4 (8,5%) alcançaram um desempenho dois níveis superior ao da avaliação anterior. O limiar obtido na audiometria em campo com o uso de IC teve média de 44,4 ± 12,4 dB NA, consideradas as frequências de 0,5; 1; 2 e 4 kHz. Quanto à expressão oral da linguagem, 13 (27,6%) crianças tiveram melhora em seu desempenho. Não houve correlação entre os resultados do PEAEE pré-implante e o limiar auditivo (p-valor=0,338) ou a categoria de linguagem (p-valor=0,358) com uso de IC quando controlado pela idade; nem em relação à melhora no desempenho de linguagem oral (p-valor= 0,095). Conclusão: Não houve correlação direta entre o limiar eletrofisiológico mensurado por meio do PEAEE e a resposta auditiva com uso de IC, quando analisados o limiar auditivo comportamental com IC ou a categoria de percepção de fala. / Background: The Auditory Steady State Response (ASSR) is an electrophysiological exam that allows simultaneous and binaural frequency specific testing of hearing thresholds. Considering its objectivity, the test has been recommended for hearing loss diagnosis in young children. This possibility of early identification of hearing impairment is fundamental for minimizing handicaps caused by sensory deprivation and for planning proper intervention, for example, suggesting the use of cochlear implants (CI). The determination of the success of CI prognosis depends on several cofactors. Researchers suggest that residual hearing and hearing thresholds before CI surgery could allow auditory pathways preservation and enable the development of hearing abilities, as well as speech production skills, after the reestablishment of sensory input. Objective: To verify the relation between pre-operatory ASSR and post-CI auditory response in young children. Casuistic and Method: An observational retrospective study was conducted. Medical records were assessed in 47 children, younger than six years old at the CI surgery, diagnosed with sensorineural pre-linguistic hearing loss of profound degree. Information was collected about (a) audiological data - ASSR, ABR, behavioral audiometry, and other hearing loss aspects; (b) category of speech perception and oral language production before and after CI; (c) socioeconomics data and therapy attendance. Results: ASSR record was present in 34 (72.4%) children with mean threshold of 89.7 (10.2 SD) dB HL in the implanted ear, considering the frequencies of 0.5; 1; 2 and 4 kHz. Post-implant evaluation was conducted after a mean of 7.2 (2.1 SD) months of surgery. Then, 23 (49%) subjects enhanced one category of speech perception and four (8.5%) improved two categories, compared to previous evaluation. Field auditory threshold with CI was measure at 44.4 (12.4 SD) dB HL in mean, considering the frequencies of 0.5; 1; 2 and 4 kHz. Analyzing language expression development, 13 (27.6%) children improved their performance. To the age at CI surgery there was no correlation between ASSR thresholds and CI thresholds (p-value=0.338) or speech perception category (p-value=0.358) after CI. No correlation has been found between ASSR and expressive language development (p-value=0.095). Conclusion: There was no direct correlation between electrophysiological thresholds measured by ASSR and hearing response after CI, when analyzed behavioral CI threshold or speech perception.
52

Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável / Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

Ramos, Henrique Faria 02 April 2013 (has links)
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom \"warble\" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal / INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
53

Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável / Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

Henrique Faria Ramos 02 April 2013 (has links)
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom \"warble\" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal / INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
54

Contribuição do avanço tecnológico do processador de fala para usuários de implante coclear Nucleus 22® / Contribution of the technological advance of the speech processor to patients with Nucleus 22®

Magalhães, Ana Tereza de Matos 03 October 2013 (has links)
Objetivo: Identificar as contribuições tecnológicas do processador de fala Freedom® para pacientes implantados com Nucleus 22® e a satisfação dos usuários com a nova tecnologia. Entre os novos recursos disponíveis, foram analisados o efeito da tabela de alocação de frequências, o T-SPL e C-SPL e o ajuste de pré-processamento do som (ADRO®). Material: Este estudo foi prospectivo e exploratório. Foram incluídos adolescentes e adultos implantados com Nucleus 22® no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, usuários efetivos do processador de fala Spectra®, com alguma percepção de frases em contexto fechado e sem experiência anterior com a nova tecnologia. Foram selecionados 17 pacientes, entre as idades de 15 e 82 anos, e implantados há mais de oito anos. Para determinar a contribuição do Freedom®, os limiares auditivos e os testes de percepção de fala foram realizados com o último mapa utilizado com o Spectra® e comparados os mapas criados com o Freedom®. Para identificar o efeito da tabela de alocação de frequências, ambos os mapas convertidos (mesma tabela) e atualizados (tabela nova) foram programados. A tabela escolhida foi mantida, e foram realizados três mapas com diferentes parâmetros: o programa 1 (P1) com T-SPL de 30 dB e do C-SPL de 70 dB, programa 2 (P2) com T-SPL de 25 dB e do C-SPL de 65 dB, e o programa 3 (P3) com ADRO®. A ordem de apresentação dos mapas e dos testes foi randomizada. Para avaliar a satisfação com seus dispositivos auditivos foram utilizados os questionários SADL e APHAB após um mês e um ano de uso do Freedom®. Resultados: A contribuição do processador de fala Freedom® para pacientes usuários do Nucleus 22® foi estatisticamente superior em comparação com o Spectra® em todos os testes de percepção da fala e em todos os limiares audiométricos, tanto individualmente quanto em média, com exceção de 8000 Hz. Em relação à escolha da tabela de frequência, 64,7% dos pacientes (n=11) mantiveram o mapa com a tabela de frequências do Spectra®. Comparando os mapas com diferentes T-SPL e C-SPL, houve diferença estatística tanto nos limiares audiométricos de 500, 1000, 1500 e 2000 Hz quanto na média. Não houve diferença estatística entre os testes de fala com ou sem o uso do ADRO®. Os questionários de satisfação mostraram uma melhora estatisticamente significativa, apenas na subescala que avalia o desempenho em ambiente ruidoso e uso do telefone. Conclusão: A tecnologia contribuiu no desempenho de percepção de fala e nos limiares audiométricos dos pacientes usuários de Nucleus22®. A maioria manteve a tabela de frequência original. As mudanças nos parâmetros de T-SPL e C-SPL mostraram uma melhora dos limiares audiométricos nas frequências principais da fala. As diferenças significantes foram sutis nos questionários de satisfação, demonstrando que os pacientes já estavam adaptados e satisfeitos com o implante coclear / Objective: To identify the technological contributions of the Freedom® speech processor to the patients implanted with Nucleus 22® and the satisfaction of users of the new technology. Among the new features available, we focused on the effect of the frequency allocation table, the T-SPL and C-SPL and the pre-processing gain adjustments (ADRO®). Methods: This study was prospective and exploratory. It included teenage and adult patients implanted with Nucleus 22® who effectively used the implant with no previous experience with the new technology and had at least some speech recognition on a closed set with the Spectra® processor. Seventeen patients met the inclusion criteria, ranging in age from 15 to 82 years and deployed for over 8 years. To determine the contribution of the Freedom®, thresholds and speech perception tests were performed with the last map used with the Spectra® and the maps created for Freedom®. To identify the effect of the frequency allocation table, both converted (same table) and upgraded (new table) maps were programmed. The table selected is maintained, and maps were performed with three different parameters: the first program (P1) was programmed with 30 dB T-SPL and 70 dB C-SPL; the second program (P2) with was programmed with 25 dB T-SPL and 65 dB C-SPL; and the program 3 (P3) with ADRO®. The order of presentation of the maps and the testing was randomized. To assess satisfaction were used SADL and APHAB after one moth and one year of using the Freedom®. Results: The contribution of the Freedom® speech processor to patients with the Nucleus 22® was statistically superior compared to the Spectra® in all tests of speech perception and in all audiometric thresholds, both individually and on average, except for 8000 Hz. Regarding the choice of a frequency allocation table, 64.7% of patients (n=11) maintained the same map that had been used with the Spectra® processor. The sound field threshold was statistically significant at 500, 1000, 1500 and 2000 Hz with 25 dB T-SPL/ 65 dB C-SPL. The patients\' satisfaction there was a statistically significant improvement, only in the sub-scale of speech in noise abilities and telephone use. Conclusions: The Freedom® technology improved the performance of patients with the Nucleus 22®. Most of the patients retained the original frequency table. The changes in the parameters of T-SPL and C-SPL showed an improvement in the audiometric thresholds for the main frequencies of speech. Significant differences were subtle in questionnaires of satisfaction, demonstrating that patients were already adapted and satisfied with the cochlear implant
55

Contribuição do avanço tecnológico do processador de fala para usuários de implante coclear Nucleus 22® / Contribution of the technological advance of the speech processor to patients with Nucleus 22®

Ana Tereza de Matos Magalhães 03 October 2013 (has links)
Objetivo: Identificar as contribuições tecnológicas do processador de fala Freedom® para pacientes implantados com Nucleus 22® e a satisfação dos usuários com a nova tecnologia. Entre os novos recursos disponíveis, foram analisados o efeito da tabela de alocação de frequências, o T-SPL e C-SPL e o ajuste de pré-processamento do som (ADRO®). Material: Este estudo foi prospectivo e exploratório. Foram incluídos adolescentes e adultos implantados com Nucleus 22® no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, usuários efetivos do processador de fala Spectra®, com alguma percepção de frases em contexto fechado e sem experiência anterior com a nova tecnologia. Foram selecionados 17 pacientes, entre as idades de 15 e 82 anos, e implantados há mais de oito anos. Para determinar a contribuição do Freedom®, os limiares auditivos e os testes de percepção de fala foram realizados com o último mapa utilizado com o Spectra® e comparados os mapas criados com o Freedom®. Para identificar o efeito da tabela de alocação de frequências, ambos os mapas convertidos (mesma tabela) e atualizados (tabela nova) foram programados. A tabela escolhida foi mantida, e foram realizados três mapas com diferentes parâmetros: o programa 1 (P1) com T-SPL de 30 dB e do C-SPL de 70 dB, programa 2 (P2) com T-SPL de 25 dB e do C-SPL de 65 dB, e o programa 3 (P3) com ADRO®. A ordem de apresentação dos mapas e dos testes foi randomizada. Para avaliar a satisfação com seus dispositivos auditivos foram utilizados os questionários SADL e APHAB após um mês e um ano de uso do Freedom®. Resultados: A contribuição do processador de fala Freedom® para pacientes usuários do Nucleus 22® foi estatisticamente superior em comparação com o Spectra® em todos os testes de percepção da fala e em todos os limiares audiométricos, tanto individualmente quanto em média, com exceção de 8000 Hz. Em relação à escolha da tabela de frequência, 64,7% dos pacientes (n=11) mantiveram o mapa com a tabela de frequências do Spectra®. Comparando os mapas com diferentes T-SPL e C-SPL, houve diferença estatística tanto nos limiares audiométricos de 500, 1000, 1500 e 2000 Hz quanto na média. Não houve diferença estatística entre os testes de fala com ou sem o uso do ADRO®. Os questionários de satisfação mostraram uma melhora estatisticamente significativa, apenas na subescala que avalia o desempenho em ambiente ruidoso e uso do telefone. Conclusão: A tecnologia contribuiu no desempenho de percepção de fala e nos limiares audiométricos dos pacientes usuários de Nucleus22®. A maioria manteve a tabela de frequência original. As mudanças nos parâmetros de T-SPL e C-SPL mostraram uma melhora dos limiares audiométricos nas frequências principais da fala. As diferenças significantes foram sutis nos questionários de satisfação, demonstrando que os pacientes já estavam adaptados e satisfeitos com o implante coclear / Objective: To identify the technological contributions of the Freedom® speech processor to the patients implanted with Nucleus 22® and the satisfaction of users of the new technology. Among the new features available, we focused on the effect of the frequency allocation table, the T-SPL and C-SPL and the pre-processing gain adjustments (ADRO®). Methods: This study was prospective and exploratory. It included teenage and adult patients implanted with Nucleus 22® who effectively used the implant with no previous experience with the new technology and had at least some speech recognition on a closed set with the Spectra® processor. Seventeen patients met the inclusion criteria, ranging in age from 15 to 82 years and deployed for over 8 years. To determine the contribution of the Freedom®, thresholds and speech perception tests were performed with the last map used with the Spectra® and the maps created for Freedom®. To identify the effect of the frequency allocation table, both converted (same table) and upgraded (new table) maps were programmed. The table selected is maintained, and maps were performed with three different parameters: the first program (P1) was programmed with 30 dB T-SPL and 70 dB C-SPL; the second program (P2) with was programmed with 25 dB T-SPL and 65 dB C-SPL; and the program 3 (P3) with ADRO®. The order of presentation of the maps and the testing was randomized. To assess satisfaction were used SADL and APHAB after one moth and one year of using the Freedom®. Results: The contribution of the Freedom® speech processor to patients with the Nucleus 22® was statistically superior compared to the Spectra® in all tests of speech perception and in all audiometric thresholds, both individually and on average, except for 8000 Hz. Regarding the choice of a frequency allocation table, 64.7% of patients (n=11) maintained the same map that had been used with the Spectra® processor. The sound field threshold was statistically significant at 500, 1000, 1500 and 2000 Hz with 25 dB T-SPL/ 65 dB C-SPL. The patients\' satisfaction there was a statistically significant improvement, only in the sub-scale of speech in noise abilities and telephone use. Conclusions: The Freedom® technology improved the performance of patients with the Nucleus 22®. Most of the patients retained the original frequency table. The changes in the parameters of T-SPL and C-SPL showed an improvement in the audiometric thresholds for the main frequencies of speech. Significant differences were subtle in questionnaires of satisfaction, demonstrating that patients were already adapted and satisfied with the cochlear implant
56

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bones

Martins, Graziela de Souza Queiroz 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant
57

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bones

Graziela de Souza Queiroz Martins 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant
58

A política nacional de atenção à saúde auditiva: avanços e entraves no município do Rio de Janeiro / National policy for health care hearing: advances and obstacles in the municipality of Rio de Janeiro

Amaral, Luciana Santos January 2009 (has links)
Made available in DSpace on 2011-05-04T12:36:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2009 / iculdades do processo de implementação da Política Nacional de Atenção à Saúde Auditiva (PNASA), no município do Rio de Janeiro. Parte-se do pressuposto que tal política ainda não está efetivamente implementada, e grande parte das realizações está restrita ao fornecimento de aparelho auditivo, com reduzido número de acompanhamentos e procedimentos essenciais para se obter um melhor resultado com o uso da prótese. Em 2004, o Ministério da Saúde elaborou a PNASA, buscando uma atuação mais efetiva para a melhoria da qualidade de vida das pessoas com problemas auditivos. No estado do Rio de Janeiro, atualmente, existem 13 unidades de Serviços de Saúde Auditiva. Dentre estas, quatro localizam-se no município do Rio de Janeiro, porém, no momento da pesquisa apenas duas encontravam-se habilitadas. Em 2005, o município apresentava cerca de 190 mil pessoas com deficiência auditiva. Verificou-se a necessidade de realizar um estudo que tratasse dos aspectos relacionados ao processo de implementação dessa Política, devido ao reduzido número de estudos sobre o assunto. A pesquisa envolveu duas etapas: a primeira incluiu entrevistas semi-estruturadas com atores-chave para uma descrição das unidades de saúde em estudo. Os atores selecionados fazem parte de dois grupos: profissionais de saúde envolvidos no atendimento de pacientes com problemas auditivos e usuários da Política. A segunda etapa refere-se à coleta de dados desde o início da habilitação de cada unidade até a época da realização da pesquisa; buscando caracterizar a demanda existente. Não se pode dizer que, hoje, no município, o atendimento ao paciente com perda auditiva seja realizado de forma integral. Apesar dos avanços conseguidos no processo de implementação da PNASA, que possibilitaram a ampliação do atendimento às pessoas com alteração auditiva, ainda existe uma necessidade de melhora no diagnóstico precoce, na agilidade da aquisição das próteses auditivas, da reabilitação e da garantia do acesso ao acompanhamento do usuário. / This research remains in a proposal to identify and discuss the main achievements and difficulties of the implementation process of National Policy for Hearing Health Care (NPHHC), in Rio de Janeiro council. It has been assumed that this policy is not effectively implemented, and most of the output is restricted to the provision of hearing, with a reduced number of accompaniments and procedures essential to get a better result with the use of the prosthesis. In 2004, the Ministry of Health produced the NPHHC, seeking a more effective action for improving quality of life for people with hearing problems. In the state of Rio de Janeiro, currently, there are 13 units of Hearing Department of Health. Among these, four are located in Rio de Janeiro, however, during this research there were only two qualified. In 2005, the council had about 190 thousand people with hearing loss. There is a need to conduct a study that treats aspects of the process of implementing this policy, due to the reduced number of studies on this subject. The research involved two stages: the first included semi-structured interviews with key players for a description of the health units under study. The actors are selected from two groups: health care professionals involved in caring for patients with hearing problems and users of policy. The second stage refers to data collection since the early clearance of each unit until the time of the completion of research seeking to characterize the existing demand. Nowadays, in the council, the care to patients with hearing loss is not made in full time. Despite the progress made in implementation of NPHHC, which enabled the expansion of care for people with hearing impairment, there is still need for improvement in early diagnosis, agility in the acquisition of hearing aids, rehabilitation and guarantees of access to monitoring user.

Page generated in 0.0433 seconds