• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 189
  • Tagged with
  • 191
  • 191
  • 165
  • 83
  • 56
  • 53
  • 51
  • 50
  • 34
  • 31
  • 27
  • 27
  • 26
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
172

Estudo do desajuste angular e vertical em próteses fixas implantossuportadas por meio do MEF-3D

Gomes, Érica Alves [UNESP] 17 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-09-17Bitstream added on 2014-06-13T19:44:52Z : No. of bitstreams: 1 gomes_ea_dr_araca.pdf: 12533208 bytes, checksum: 62db616b630b0f9a9807e6b24297d9e8 (MD5) / Objetivo: A análise pelo método dos elementos finitos tridimensional foi utilizada para avaliar o efeito dos desajustes angular e vertical simulado em próteses fixas implantossuportadas parafusadas de 3 elementos, na resposta biomecânica do tecido ósseo peri-implantar, implantes e componentes protéticos. Material e método: Foram confeccionados 4 modelos tridimensionais, representativos de secção mandibular direita contendo um implante na região de segundo pré-molar (2oPM) e outro na região de segundo molar (2oM) ferulizados por uma prótese metalocerâmica implantossuportada parafusada de 3 elementos, diferenciados pelo tipo de desajuste protético, gerando os grupos: GC (grupo controle) - prótese totalmente adaptada aos implantes, DAU (desajuste angular unilateral) - prótese com desajuste angular unilateral de 100μm na região mesial do 2oM, DVU (desajuste vertical unilateral) - prótese com desajuste vertical unilateral de 100μm na região mesial do 2oM e DVT (desajuste vertical total) - prótese com desajuste vertical de 100μm em toda a plataforma de assentamento da infraestrutura no 2oM. Com a utilização do programa de elementos finitos Ansys® uma força vertical total de 400N foi distribuída em 12 pontos de parada cêntrica, sendo que cada molar recebeu um carregamento total de 150N e o 2oPM de 100N, gerando mapas de tensões. Resultados: Verificou-se que a distribuição e os valores de tensões para o tecido ósseo peri-implantar foram similares para todos os grupos. Os grupos com desajustes alteraram o padrão de distribuição e elevaram a magnitude das tensões em relação ao grupo GC. No grupo DAU os maiores valores de tensões foram observados no corpo do implante e parafuso de retenção. Já nos grupos DVU e DVT elevados valores de tensões foram encontrados na plataforma de assentamento da infraestrutura... / Purpose: The three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in 3-piece implant-supported and screw-retained fixed prostheses on biomechanical response in peri-implant bone tissue, implants and prosthetic components. Material and method: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of second premolar (2°PM) and other in the region of second molar (2°M). The implants were splinted by a 3- piece implant-supported metal ceramic prosthesis and differed according to the type of misfit as represented by the groups: CG (control group) - prosthesis with complete fit to the implants, UAM (unilateral angular misfit) – prosthesis presenting unilateral angular misfit of 100μm in the mesial region of the 2°M, UVM (unilateral vertical misfit) – prosthesis presenting unilateral vertical misfit of 100μm in the mesial region of the 2°M, and TVM (total vertical misfit) – prosthesis presenting total vertical misfit of 100μm in the platform of the framework in the 2°M. A vertical load of 400N was distributed and applied on 12 centric points by the software Ansys®. So, vertical loading of 150N was applied on each molar while vertical load of 100N was applied on the 2°PM. Stress maps were obtained by processing of the finite element software. Results: The stress values and distribution on peri-implant bone tissue were similar for all groups. The groups presenting misfit exhibited different distribution pattern and increased stress magnitude in comparison to the group CG. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework... (Complete abstract click electronic access below)
173

Avaliação do aquecimento ósseo, da viabilidade celular imediata e da deformação de fresas de alta resistência após osteotomia para implantes em tíbias de coelhos

Carvalho, Abrahão Cavalcante Gomes de Souza [UNESP] 15 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-15Bitstream added on 2014-06-13T20:30:33Z : No. of bitstreams: 1 carvalho_acgs_me_araca.pdf: 682833 bytes, checksum: 3da34d67f34af6e497f53ac11e8e701c (MD5) / O propósito deste trabalho foi avaliar a influência da reutilização de fresas de alta resistência sobre o aquecimento ósseo, a viabilidade celular imediata e a deformação das fresas após osteotomia para implantes em tíbias de coelhos. Para isso, foram utilizados 12 coelhos machos brancos (Oryctolagus cunilicus, Nova Zelândia), que foram submetidos a 200 sequências de fresagens para implantes na cortical superior de suas tíbias. Foram estabelecidos 6 grupos (G1 a G6) que correspondiam ao número de osteotomias realizadas por cada fresa (0, 10, 20, 30, 40 e 50). Cada leito cirúrgico recebia a seguinte sequência de fresagem: fresa tipo lança e helicoidais de 2,0mm, 2,8mm, 3,0mm e 3.15mm. As áreas osteotomizadas foram coletadas para análise imunoistoquímica, as oscilações térmicas foram quantificadas e as fresas utilizadas receberam análise por microscopia eletrônica de varredura. Nos resultados, houve uma correlação alta entre a porcentagem de deformação e o número de reutilização de cada fresa (Coeficiente de Correlação de Pearson r = 0,984). Observou-se também que as fresas do tipo lança apresentaram maior deformação após o uso do que as fresas helicoidais (proporção de 2:1). Não houve correlação estatística significativa entre aumento da reutilização da fresa e aquecimento ósseo (p > 0,05). No entanto, observouse que a oscilação térmica durante a fresagem da lança é maior que as demais fresagens (proporção de 3:1). Na análise imunoistoquímica, observou-se um equilíbrio fisiológico da expressão das proteínas Osteoprotegerina e RANKL em todos os grupos, no entanto, houve maior expressão de todas as proteínas no Grupo 6. De acordo com a metodologia aplicada, foi possível concluir que as fresas avaliadas não causam aquecimento ósseo significativo em até 50 reutilizações, no entanto, causam maior trauma tecidual na 50ª fresagem... / The purpose of this study was evaluate the influence of high resistence drill reuse over bone heating, immediate bone-cell viability and drills wear after implant osteotomies in rabbit tibias. Therefore, 12 male white rabbits (Oryctolagus cunilicus, New Zealand) received 200 implant sequential osteotomies over the superior cortical of their tibia. Six groups were established (G1 to G6), according to the number of osteotomy of each drill (0, 10, 20, 30, 40 and 50). The implant sequence of drills was: spear drill, 2,0mm, 2.8mm, 3.0mm and 3.15mm helicoidal drills. The receptor-beds were collected to imunohistochemistry, the thermal changes were quantified and the drills received scanning electron microscopy analysis. In the results, a great correlation degree between drill wear and number of osteotomies was observed (Pearson’s Correlation Coefficient r = 0,984). Another result was that spear drill have more deformation than helicoidal drills (2:1 proportion). The bone heating analysis concluded that there was no statistical siginificance between number of osteotomy and bone heating (p > 0,05). However, the thermal changes during spear drilling was greater than during helicoidal drillings (3:1 proportion). Imunohistochemistry results showed a physiological balance of Osteoprotegerin and RANKL immunolabeling in all groups, however there was a greater immunolabeling of all proteins in the last group. According to this metodology, the conclusion is that the tested drills do not caused significant bone heating after 50 reuses, however, they caused more tissue trauma at 50th osteotomy. So, the studied system must be reused for 40 times, and the spier drill must be substituted after 20 osteotomies.
174

Reconstrução alveolar por aumento do assoalho do seio maxilar com beta-tricálcio fosfato ou osso autógeno para reabilitação com prótese implantossuportada / Alveolar reconstruction by enlargement of the maxillary sinus floor with beta-tricalcium phosphate or autogenous bone for rehabilitation with implant-supported prosthesis

Ferreira, Sabrina [UNESP] 06 October 2017 (has links)
Submitted by SABRINA FERREIRA null (sabrife@bol.com.br) on 2017-10-26T16:31:30Z No. of bitstreams: 1 TESE FINAL.docx: 68772200 bytes, checksum: f6722c6fe1365b9fe81b2aa5d5b01539 (MD5) / Rejected by Monique Sasaki (sayumi_sasaki@hotmail.com), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Por favor, corrija o formato do arquivo e realize uma nova submissão. Agradecemos a compreensão. on 2017-10-31T17:57:48Z (GMT) / Submitted by SABRINA FERREIRA null (sabrife@bol.com.br) on 2017-11-02T18:44:52Z No. of bitstreams: 1 TESE FINAL.pdf: 1299336 bytes, checksum: 6585035d2ca784a2d052292a49407084 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-11-10T18:05:35Z (GMT) No. of bitstreams: 1 ferreira_s_dr_araca.pdf: 1299336 bytes, checksum: 6585035d2ca784a2d052292a49407084 (MD5) / Made available in DSpace on 2017-11-10T18:05:35Z (GMT). No. of bitstreams: 1 ferreira_s_dr_araca.pdf: 1299336 bytes, checksum: 6585035d2ca784a2d052292a49407084 (MD5) Previous issue date: 2017-10-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A altura insuficiente do osso alveolar é um fator limitante para a reabilitação oral com próteses implantossuportadas. Taxas de sucesso clínico com uso de biomateriais à base de beta-tricálcio fosfato (b-TCP) para elevação do assoalho do seio maxilar (EASM) mostraram que são excelentes alternativas ao osso autógeno (OA). Portanto, objetivo foi avaliar a formação óssea do enxerto de b-TCP em bloco, seis meses após EASM, comparada ao OA por meio de análises tomográfica, microtomográfica e histomorfométrica. Para isso, Oito seios maxilares foram enxertados com b-TCF e sete OA. Após 6 meses, foram obtidas biópsias durante à instalação de implantes dentários. Não houve diferença significante (ANOVA) entre a contração do volume dos seios maxilares preenchidos por OA e b-TCP (p=0,113), bem como para todos os parâmetros microtomográfico (ANOVA) BV/TV (p=0.089), Tb.Th (p=1.000), Tb.Sp (p=0,989) e Tb.N (p=0.917). Na histomorfometria quando comparada a porcentagem ósseo em OA e b-TCP também não foi encontrada diferença estatística (ANOVA, p=0,794). Em conclusão, os resultados deste estudo indicam que ambos OA e b-TCP são adequados para o uso com segurança para o procedimento de EASM pela técnica da janela lateral. O material sintético apresenta boa estabilidade volumétrica com formação óssea semelhante ao OA suportada pelos parâmetros em análises 2D e 3D que se complementam. No entanto, a metodologia da análise volumétrica utilizada neste estudo parece representar a estabilidade volumétrica geral do procedimento, não somente do biomaterial, quando na técnica for utilizado o enxerto em bloco e não particulado. / The insufficient height of the alveolar bone is a limiting factor for oral rehabilitation with implants. Clinical success rates using beta-tricalcium phosphate (b-TCP) biomaterials for maxillary sinus floor elevation (MSFE) have been shown to be excellent alternatives to autogenous bone (AB). Therefore, the objective was to evaluate bone formation of the b-TCP graft in a block, six months after MSFE, compared to AB by means of tomographic, microtomographic and histomorphometric analyzes. For this, eight maxillary sinuses were grafted with b-TCF and seven AB. After 6 months, biopsies were obtained during the installation of dental implants. There was no significant difference (ANOVA) between the volume contraction of the maxillary sinus filled by AB and b-TCP (p = 0.113), as well as for all microtomographic parameters (ANOVA) BV/TV (p = 0.089), Tb.Th (p = 1.000), Tb.Sp (p = 0.989) and Tb.N (p = 0.917). In histomorphometry, when comparing bone percentage in AB and b-TCP, no statistical difference was found (ANOVA , p = 0.794). In conclusion, the results of this study indicate that both AB and b-TCP are suitable for safe use for the MSFE procedure by the side window technique. The synthetic material presents good volumetric stability with bone formation similar to AB supported by the parameters in 2D and 3D analyzes that complement each other. However, the volumetric analysis methodology used in this study seems to represent the general volumetric stability of the procedure, not only of the biomaterial, when in graft and non-particulate graft technique.
175

Sobrevida de implantes submetidos à carga funcional imediata na região interforaminal através do uso de anéis de retenção isolados em uma prótese total removível / Survival rates of implants submited to immediate funcional load in the interforaminal region using retention rings on a removable complete denture

Renato da Silva Fraga 12 March 2009 (has links)
O presente trabalho teve como objetivo comparar clinicamente através da taxa de sobrevida e análise de freqüência de ressonância, dois implantes instalados na região anterior da mandíbula, submetidos à carga funcional imediatamente a instalação dos implantes, através de anéis de retenção isolados presos a uma sobredentadura, com um implante instalado na mesma região, livre de carga funcional. Com este objetivo, onze pacientes foram selecionados para instalação de três implantes osteointegráveis em cada, sendo o implante livre de cargas funcionais utilizado como grupo controle. Através dos resultados obtidos, dos vinte e dois implantes submetidos à carga funcional imediata, dois foram perdidos, apresentando uma taxa de sobrevida proporcional a amostra de 93.9%. Quanto ao grupo controle, nenhum implante foi perdido. Após 4 anos de controle clínico, todos os implantes apresentam-se osteointegrados. / The present study aimed to clinically compare through resonance frequency analysis and survival rate, one implant installed in the mandibular anterior region, free from functional load, with two implants installed in the same region, submitted to immediate functional load through isolated retention rings attached to an overdenture. With this purpose, eleven patients were selected for installation of three implants in each. The implants free from functional load were used as the control group. Through the obtained results, two implants of the twenty-two implants submitted to immediate functional load were lost, representing a survival rate of 93.9%. As for the control group, no implants were lost. After 4 years of clinical control all implants remained integrated.
176

Mensuração do torque de desaperto do componente protético em conexão do tipo cone-morse em implantes dentários utilizando deposição de carbono sobre a superfície de atrito / Measurement of the morse taper abutment removal torque in dental implants using a carbon deposition above the attrition surface

Alexandre do Valle Wuo 10 February 2009 (has links)
Os implantes cone morse apresentam um travamento e vedamento por meio de atrito entre as paredes do implante e do pilar protético. Nos sistemas convencionais do tipo Hexágono externo e interno, para reduzir o afrouxamento dos parafusos protéticos, são utilizados materiais de cobertura de superfície, como carbono e ouro. Não foram encontradas referências na literatura da utilização desse tipo de deposição em componentes do sistema cone morse. O propósito desse estudo é mensurar, registrar e avaliar os valores do torque de desaperto em pilares protéticos dos tipos sólido e parafuso passante do sistema cone morse com a deposição de carbono na zona de atrito do pilar protético. Foram utilizados 40 implantes cone morse com seus respectivos pilares divididos em 4 grupos (n=10): G1- pilar sólido; G2- pilar sólido com deposição de carbono na zona de atrito do sistema morse; G3- estudo somente do parafuso do pilar passante; G4- estudo somente do parafuso do pilar passante com deposição de carbono na ponta ativa; G5- estudo somente do pilar passante sem ação do parafuso; G6- estudo somente do pilar passante revestido em carbono na zona de atrito do sistema morse sem ação do parafuso. Cada pilar recebeu uma seqüência de 5 apertos e desapertos (20Ncm para o pilar sólido e 10Ncm para o parafuso passante). Os resultados mostraram no teste estatístico ANOVA para dois fatores de variação (desaperto e carbono), haver diferença estatística significante entre os grupos: G1 maior que G2 (p < 0,01); G4 maior que G3 (p < 0,01); G6 maior que G5 (p < 0,01). Esse estudo concluiu que o grupo controle G1 mostrou maior valor através da media aritmética (23,706 Ncm) em relação ao grupo experimental G2 (22,114 Ncm); o grupo experimental G4 mostrou maior valor através da media aritmética (8,218 Ncm) em relação ao grupo controle G3 (7,354 Ncm) e o grupo experimental G6 mostrou maior valor através da media aritmética (10,268 Ncm) em relação ao grupo controle G5 (6,906 Ncm), mostrou também que não houve diferença significativa (p > 0,01) para o fator desaperto em todos os grupos estudados, ou seja, não houve interferência da deformação do material com a repetição dos ciclos de aperto e desaperto. / The morse taper implants present a locking and sealing by means of the attrition between implants internal walls and the abutment. In the external and internal conventional hexagon system, to reduce the prosthetic screw loosing, its used covering surface materials, as carbon and gold. Literature reference using these kind of surface deposition were not found in morse taper abutment implants. The aim of this study is to measure, register and evaluate the removal torque values in morse taper solid abutment and passing screw abutment with carbon deposition in attrition zone. They were used 40 morse taper implants with their respective abutments divided in 4 groups (n = 10): G1 solid abutment; G2 - solid abutment with carbon deposition in attrition zone; G3 evaluation only in the screw of the passing abutment; G4 - evaluation only in the screw of the passing abutment with carbon deposition in the screw thread; G5 - evaluation only in the passing abutment without the screw action; G6 - evaluation only in the passing abutment with carbon deposition in attrition zone without the screw action. Each abutment received a sequence of 5 tightening and removal torque (20Ncm in solid abutment and 10Ncm in passant screw abutment). The results of ANOVA statistic test for two factors of variation (removal torque and carbon), showed that there is significant statistic difference between the groups: G1 higher than G2 (p < 0.01); G4 higher than G3 (p < 0.01); G6 higher than G5 (p < 0.01). This study concluded that control group G1 showed a higher value through the arithmetical media (23.706Ncm) in relation of the experimental group G2 (22.114Ncm); the experimental group G4 showed higher value through the arithmetical media (8.218Ncm) in relation of the control group G3 (7.354Ncm) and the experimental group G6 showed higher values through the arithmetical media (10.268Ncm) in relation of the control group G5 (6.906Ncm), and also showed that there was not significant difference (p < 0.01) to the removal torque factor in all the groups studied, that is, there was not a material deformation interference with the tightening and removal torque cycles repetition.
177

Relação da distância interimplantar e altura do ponto de contato na formação de papilas gengivais: estudo em cães / Influence of interimplantar distance and height from the point of contact in the formation of gingival papilae: a study in dogs

Diogo Rodrigues Cruvinel 24 April 2009 (has links)
Os implantes dentais são considerados uma modalidade de tratamento bastante previsível para a reposição de dentes perdidos. Os implantes osseointegráveis principalmente quando colocados em regiões anteriores devem oferecer, além de excelente função, ótima estética, e fonética. Sendo que o critério para o sucesso envolve o estabelecimento do contorno de tecido mole, apresentando a área interproximal intacta. O propósito deste estudo foi avaliar a influência das diferentes distâncias (3 e 5 mm) entre a crista óssea e ponto de contato interdental, na formação de papila gengival associado à presença de diferentes distâncias (2 e 3 mm) entre implantes contíguos e na região de extremo livre mesial e distal. Foram selecionados para o experimento 8 cães adultos jovens e executada a exodontia dos 4 pré-molares mandibulares: p1, p2, p3, p4, para cada hemi-mandibula. Três meses após as exodontias foram colocados 3 implantes Replace Select Tapered com superfície tratada e dimensões de 4,3 X 10 mm, em cada hemimandibula animal. O primeiro implante foi colocado a 10 mm da distal do canino remanescente, o segundo (intermediário) foi colocado a 2 mm do primeiro e o terceiro implante (posterior) foi colocado a 3 mm do segundo. Foi iniciada a reabilitação protética, no dia da colocação dos implantes. Primeiramente foi feita a moldagem para a confecção das próteses metálicas. As coroas metálicas definitivas, confeccionadas, apresentaram distância do ponto de contato à crista óssea de 3 e 5 mm lado esquerdo e direito respectivamente. Ao completar 12 semanas pós-colocação das próteses definitivas, os animais foram sedados e as análises clínicas foram executadas. Esta avaliação foi feita a partir da utilização de um compasso de pontas secas, medindo as distâncias entre os pontos de contato e as pontas das papilas (PC - P) e dos pontos de contato aos extremos livres mesial e distal (PC - ELM e PC ELD respectivamente). O delineamento das situações experimentais foi executado levando em consideração as associações das diferentes distâncias interimplantar com as diferentes distâncias do ponto de contanto a crista óssea, assim encontramos a seguinte disposição: Situação 01 (PC3A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado esquerdo; Situação 02 (PC3B) Distância do ponto de contato, a gengiva interproximal sendo à distância interimplantar de 2 mm, lado esquerdo da mandíbula; Situação 03 (PC3C) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado esquerdo da mandíbula; Situação 04 (PC3D) Distância do ponto de contato a gengiva do extremo livre distal, do lado esquerdo Situação 05 (PC5A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado direito; Situação 06 (PC5C) Distância do ponto de, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado direito da mandíbula; Situação 07 (PC5B) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 2 mm, lado direito da mandíbula e Situação 08 (PC5D) Distância do ponto de contato a gengiva do extremo livre distal, do lado direito. Ao analisar as medias das alturas gengivais temos: PC3A a média de 2,9±0,5 mm; PC3D 2,5±0,5 mm; PC3B 1,8±0,6 mm; PC3C 2,0±0,8 mm; PC5A 3,0±0,5 mm; PC5D 3,5±0,4 mm; PC5C 3,6±0,4 mm e PC5B 3,9±0,7 mm. Como as premissas de aderência à distribuição normal, independência entre os indivíduos estudados e pareamento entre as diferentes etapas foram cumpridas, empregou-se a análise de variância (ANOVA) para mensurações repetidas, a dois fatores. Nos casos em que a ANOVA encontrou diferença entre as situações testadas, uma comparação a posteriori foi executada por meio do teste de Bonferroni. O nível de significância empregado para todos os testes foi de 0,05 (5%). Logo as distâncias de 2,0 e 3,0 mm entre implantes contíguos não apresentaram diferença significativa na formação de papila quando as restaurações protéticas são confeccionadas com 3 ou 5 mm de distância entre o ponto de contato e a crista óssea. Considerando a provável reabsorção óssea em ambos os grupos, quando a distância do ponto de contato à crista óssea foi inicialmente de 3 mm esta condição apresentou melhores resultados na formação de papilas do que a distância de 5 mm em todas as situações estudadas. A presença do ponto de contato de 3 mm influência positivamente na formação de papila, quando comparada com as regiões de extremo livre. / The dental implants are considered a form of treatment rather predictable for replacement of lost teeth Implants should offer, as well as excellent function, aesthetics and phonetics great, especially when placed in anterior regions, where the criterion for success involves the establishment contour of the soft tissue, showing the area intact interproximal The purpose of this study was to evaluate the influence of different distances between the bone crest and interdentally contact point, with 3 and 5 mm, the formation of gingival papilla associated with the presence of different distances of 2 and 3 mm between implants and the adjacent region of mesial and distal end free. Were selected for the experiment 08 dogs and young adults performed the extraction of the 4 pre molars mandibles: p1, p2, p3, p4, for each hemi-mandible. Three months after the tooth extractions were placed 3 Replace Select Tapered implants with treated surface and dimensions of 4.3 X 10 mm in each animal hemi mandibles. The first implant was placed at 10 mm distal of the canine left, the second (middle) was placed at 2 mm from the first and third implant (back) was placed at 3 mm from the second. Prosthetics rehabilitation has begun on the day of the placement of implants. First was the casting for the manufacture of metal stents, since the provisional prostheses were made of acrylic resin so that the distance between the point of contact and the bone crest is 3 mm on the left side of the mandible and 5 mm on the right. The final metal crowns, made, made from the point of contact to bone crest of 3 and 5 mm. After completing 12 weeks after placement of final prosthesis, the animals were sedated and the clinical tests were performed. This evaluation was made from the use of a dry bar for tips, measuring the distances between the points of contact and the tips of the papillae (PC - P) and the contact points of the mesial and distal ends free (PC - PC and ELM - ELD respectively). The design of the experimental situations was implemented taking into account the associations of different distances interimplantar with different distances from the long bone crest, we found the following provision: Location - 01 (PC3A) Distance from the point of contact to end the free gingiva mesial to the left; Situation - 02 (PC3B) Distance from the point of contact, the gingival interproximal distance being interimplantar of 2 mm, the left side of the mandible; Situation - 03 (PC3C) Distance from the point of contact, the gingival interproximal and interimplantar a distance of 3 mm, the left side of the mandible; Situation - 04 (PC3D) Distance from the point of contact to the extreme free gingival distal to the left position - 05 (PC5A) Distance from the point of contact to the extreme free gingival mesial on the right side; Situation - 06 (PC5C) distance from the interproximal gingival interimplantar the distance of 3 mm, right side of the jaw; Situation - 07 (PC5B) Distance from the point of contact, the gingival interproximal the distance interimplantar of 2 mm, the right side of the mandible and Situation - 08 (PC5D) Distance from the point of contact to free distal end of the gingival on the right side. In examining the measures of gingival heights are: PC3A an average of 2.9 ± 0.5 mm; PC3D 2.5 ± 0.5 mm; PC3B 1.8 ± 0.6 mm; PC3C 2.0 ± 0.8 mm; PC5A 3.0 ± 0.5 mm; PC5D 3.5 ± 0.4 mm; PC5C 3.6 ± 0.4 mm and PC5B 3.9 ± 0.7 mm. As adherence to the assumptions of normal distribution, independence among the subjects studied and matching between the different stages have been completed, using the analysis of variance (ANOVA) for repeated measurements, the two factors. Where ANOVA found the difference between the conditions tested, a posteriori comparison was performed using the Bonferroni test. The significance level used for all tests was 0.05 (5%). Once the distances of 2.0 and 3.0 mm between adjacent implants showed no significant difference in the formation of the papilla when prosthetic restorations are made with 3 or 5 mm distance between the point of contact and the bone crest. Considering the probable bone resorption in both groups, where the distance from the point of contact to the bone crest was originally the condition of 3 mm showed better results in the formation of papillae than the distance of 5 mm in all cases studied. The presence of the point of contact 3-mm positively influence the formation of papilla, when compared with regions of extreme freedom.
178

Avaliação da microestrutura óssea de sítios implantares e fatores relacionados às alterações no nível ósseo marginal e estabilidade de implantes dentários: estudo clínico prospectivo / Assessment of microstructure of jawbone sites and factors related to the changes on marginal bone level and dental implant stability: prospective clinical study

Dias, Danilo Rocha 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T17:49:23Z No. of bitstreams: 1 Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-12T17:49:32Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:43:01Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:25:37Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Made available in DSpace on 2014-12-16T09:25:37Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) Previous issue date: 2013-07-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Bone characteristics influence surgical/prosthetic planning of implant treatment, but it is not clear their influence on longitudinal outcomes. This study aimed to investigate the association between jawbone microstructure and changes on marginal bone level (MBL) and implant stability (IS) after loading, in a 1-year follow-up. Forty-one volunteers received 97 dental implants, installed in bone sites classified from 1 to 4, according to Leckholm & Zarb (1985). Cortical bone thickness was measured on computed tomography images. Histomorphometric and microtomographic analyses were performed in bone specimens obtained by using a trephine bur, at first drilling. Peak insertion torque (PIT) and implant stability quotient (ISQ) measured by resonance frequency analysis (RFA) were registered at implant insertion. Periapical radiographs were standardized to measure the MBL, and were taken at three moments, when the ISQ was also measured: at uncovering stage, at loading and at 1-year follow-up. Agreement analysis between histomorphometry and microcomputed tomography (microCT) showed that these methods are complementary, but not interchangeably. Association tests revealed that ISQ changes were not affected by MBL changes. Bone type 4 (according L&Z) presented higher changes on ISQ, especially during osseointegration. Microstructure parameters (histomorphometric and microCT parameters) and cortical thickness did not influence ISQ changes and MBL changes. These results suggest that bone characteristics influence primary implant stability, but do not predict implant success after osseointegration. / Características do tecido ósseo influenciam o planejamento cirúrgico/protético dos implantes dentários, mas não está clara sua relação com o resultado longitudinal do tratamento com implantes. O objetivo deste estudo foi investigar a associação entre microestrutura óssea de sítios implantares da maxila e mandíbula, as alterações de nível ósseo marginal (MBL) e a estabilidade dos implantes (IS) até o período de 1 ano após a aplicação de carga oclusal. Quarenta e um pacientes receberam 97 implantes dentários, instalados em sítios ósseos classificados como tipos 1 a 4, de acordo com a classificação de Leckholm & Zarb (1985). A espessura de osso cortical foi mensurada em imagens de tomografia computadorizada. Análises microtomográficas e histomorfométricas foram realizadas em espécimes ósseos obtidos com trefina na primeira perfuração para instalação dos implantes. Torque de inserção final (PIT) e quociente de estabilidade do implante (ISQ) medido por análise de freqüência de ressonância (RFA) foram registrados durante a instalação dos implantes. Radiografias periapicais padronizadas para mensuração do MBL foram obtidas em tres momentos, quando novos registros do ISQ foram também realizados: durante a cirurgia de reabertura, na instalação das próteses e 1 ano após aplicação da carga oclusal. A análise de concordância entre os métodos de microtomografia computadorizada (microCT) e histomorfometria, mostrou que estes métodos são complementares, mas não intercambiáveis. Testes de associação mostraram que as alterações na IS não foram afetadas pelas alterações no MBL. Ossos classificados como tipo 4 apresentaram as maiores alterações da IS, principalmente durante a osseointegração. Os parâmetros microestruturais (parâmetros microtomográficos e histomorfométricos) e a espessura de cortical não influenciaram as alterações de IS e do MBL. Estes resultados sugerem que as características do sítio ósseo influenciam a estabilidade primária, mas não são preditores do sucesso dos implantes após a osseointegração.
179

Análise tridimensional comparativa de reabilitações para a região posterior da mandíbula, por meio do método de elementos finitos / Three-dimensional comparative analysis of rehabilitations for the posterior mandible, with the Finite Element Method

Marco Antonio Amorim Vasco 05 November 2010 (has links)
A reabilitação da região posterior da mandíbula com implantes dentários é complexa, especialmente em casos de reabsorção óssea moderada a severa. Embora existam diversas possibilidades de tratamento para essa região, os implantes curtos e a lateralização tem se destacado como alternativas viáveis e de menor tempo de tratamento. O objetivo deste trabalho foi avaliar, comparativamente, o risco mecânico dos dois tratamentos mencionados, com especial atenção ao risco de perda óssea e de fratura do parafuso. Para tanto, foram processadas tomografias de mandíbulas e realizada engenharia reversa de implantes e componentes protéticos para reconstrução de modelos tridimensionais, a fim de simular o comportamento biomecânico de próteses parciais fixas de três elementos, suportadas por dois implantes, utilizando simulações com o Método dos Elementos Finitos. Os modelos de implantes utilizados foram baseados nos implantes MK III (Nobel Biocare), com 5 e 4 mm de diâmetro por 7 de comprimento, representando implantes curtos, e com 4 e 3.75 mm de diâmetro por 15 de comprimento, representando implantes sob tratamento de lateralização do nervo alveolar inferior. Modelos distintos foram confeccionados para representar implantes tratados em um estágio (carga imediata) e dois estágios (implantes osseointegrados). Todos os modelos receberam simulação prévia de pré-tensão, referente a tensão gerada pelo torque do parafuso. Um padrão de carga oclusal axial e outro com carga oclusal oblíqua em 45% foram simulados, resultando em 16 diferentes simulações. A análise dos resultados revelou que o risco mecânico para perda óssea na região periimplantar, quando analisados implantes colocados em dois estágios, é maior para tratamentos com implantes curtos. Entretanto, para implantes colocados em um estágio, o maior risco de perda óssea foi para os implantes colocados com lateralização do nervo alveolar inferior. Quanto aos resultados dos parafusos, embora não se observou claras tendências quando simuladas cargas axiais, sob cargas oblíquas, os implantes de maior diâmetro e menor comprimento tiveram o menor risco à fratura do parafuso. / The rehabilitation of the posterior region of the mandible with dental implants is complex, especially in cases of moderate to severe bone loss. While there are several treatment options for this region, the use of short implants and lateralization has emerged as viable alternatives with less treatment time. The objective of this study was to comparatively evaluate the mechanical risk of both treatments mentioned, with special attention to the risk of bone loss and screw fracture. For this, CT scans of mandibles were processed and implants and prosthetic components were reverse engineered for reconstruction of three dimensional models to simulate the biomechanical behavior of fixed partial dentures of three elements, supported by two implants, using simulations with the Finite Element Method. The models of implants were based on MK III implants (Nobel Biocare) with 5 and 4 mm in diameter by 7 mm in length, representing short implants, and 4 and 3.75 mm in diameter by 15 mm long, representing implants used in treatments with lateralization of the inferior alveolar nerve. Several models were modeled to represent implants treated in one stage (immediate load) and two stages (osseointegrated implants). All models were simulated with pre-stress concerning the stresses generated by the torque of the screw. Axial and oblique oclusal loads at 45% were simulated, resulting in 16 different simulations. The results showed that the mechanical risk for bone loss, when osseointegrated implants were analyzed, is greater for treatments with short implants. However, for implants placed in one stage, the increased risk of bone loss was for implants placed with lateralization of the inferior alveolar nerve. Concerning the results of screws, there were no clear trends when axial loads were simulated, however, under oblique loads, the implants of larger diameter and shorter length had the lowest risk of screw fracture.
180

Estudo sobre o comportamento biomecânico de implantes curtos com variação da espessura da cortical óssea por meio do método dos elementos finitos / Biomechanical behavior of short implants varying thickness of cortical bone by finite element method

José Augusto Conde Neto 01 October 2012 (has links)
Este estudo teve como objetivo analisar e comparar o comportamento biomecânico de um implante de comprimento curto com um implante de comprimento padrão, no que diz respeito às tensões ósseas ao redor do implante. Foi considerado como variável o aumento da espessura óssea cortical, em dois tipos: fino e espesso. Os modelos de elementos finitos em três dimensões (3D) foram criados a partir de uma secção de mandíbula de 20 mm, referente ao segundo pré-molar, com um implante endósseo único inserido dentro do osso esponjoso com cortical fina de 0,5 mm e cortical espessa de 2,0 mm. Uma carga oclusal vertical de 100 N e uma carga oblíqua de 40 N foram aplicadas. Os ossos cortical e esponjoso foram considerados isotrópicos e linearmente elásticos e o critério de avaliação foi o de tensões de von Mises. O implante curto utilizado foi de 4,1 mm de diâmetro por 6,0 mm de comprimento, e o implante padrão de 4,1 mm de diâmetro por 10,0 mm de comprimento (ambos da marca Straumann®). A prótese sobre o implante foi composta por um pilar sólido de 5,5 mm de altura e por uma coroa de segundo pré-molar. Conforme as simulações pelo MEF, pôde-se concluir que: 1) O aumento da espessura óssea favoreceu uma melhor distribuição das tensões, registrando valores mais baixos na região cervical cortical. 2) O modelo de implante curto na situação de cortical espessa apresentou melhores resultados biomecânicos comparado com o modelo de implante padrão na situação de cortical fina. / The aim of this monograph was to analyze and compare the biomechanical behavior of a short length implant against a standard length implant, regarding stress distribution on the bone around the implant. Bone cortical thickness of the ridge was considered as thin and thick. The 3D finite element models were created of a 20-mm second premolar section of the mandible with a single endosseous implant embedded in cancellous bone with thin cortical of 0.5 mm and with thick cortical of 2.0 mm. A vertical occlusal load of 100 N and an oblique load of 40 N were applied. The cortical and cancellous bone were considered to be isotropic and linearly elastic Von Mises stress criterion was used for analysis. The short implant used was of 4.1 mm of diameter and 6 mm in length, and the standard implant was of 4.1 mm of diameter and 10 mm in length (both Straumann ®). The prosthesis on the implant consisted of a solid abutment of 5.5 mm in height and a crown of second premolar. Conclusions: 1) Increasing bone thickness favored a better stress distribution, showing lower values in the cervical cortical bone. 2) Short implants with thin cortical situations showed better biomechanical results compared to standard implants with thick cortical situations.

Page generated in 0.0774 seconds