• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 189
  • Tagged with
  • 191
  • 191
  • 165
  • 83
  • 56
  • 53
  • 51
  • 50
  • 34
  • 31
  • 27
  • 27
  • 26
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Intercambialidade de componentes protéticos em diferentes marcas de implantes / Evaluation of the connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy

Zanardi, Piero Rocha 05 November 2012 (has links)
O presente estudo avaliou a intercambiabilidade dos componentes protéticos de implantes de hexágono externo medindo-se a precisão da interface implante/pilar (I/P) com microscopia eletrônica de varredura. Foram utilizados dez implantes para cada uma de três marcas (SIN, Conexão, Neodent) com seus respectivos pilares (base metálica de CoCr , rotacional e não rotacional) e um de marca alternativa (Microplant) em um arranjo com todas as combinações de I/P possíveis. O valor de referência para a intercambiabilidade das várias marcas de componentes foi definido pela diferença do pilar original para com seu respectivo implante. Dessa maneira, a intercambiabilidade foi considerada válida quando o resultado para um determinado pilar colocado sobre um implante fosse igual ou menor que a diferença medida, quando o pilar da mesma marca do implante foi posicionado. Um grau de desajuste foi observado em todos os espécimes. De uma maneira geral, o pilar antirrotacional foi mais preciso do que o rotacional. Estes variaram de 0,6 16,9m, com mediana 4,6m, enquanto o antirrotacional foi de 0,3 12,9m, com mediana de 3,4m. Os espécimes com o pilar e o implante Conexão tiveram uma diferença maior que o conjunto original para SIN e NEO (p<0,05). Apesar de estes últimos apresentarem resultados semelhantes com seus respectivos pilares, quando trocados, não mantiveram a mesma precisão original. Os resultados sugerem que a marca alternativa seria a única que apresentaria compatibilidade com todos os sistemas, enquanto as outras marcas não seriam completamente intercambiáveis. / The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface using scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and that of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the component of the same brand as the implant was positioned, interchangeability was considered valid. Some degree of maladjustment was observed on all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6 16.9m, with a median of 4.6m; the former from 0.3 12.9m, with a median of 3.4m. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for Sin and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.
162

Comparação entre ressonância magnética e tomografiacomputadorizada por feixe cônico para diagnóstico de regiões com enxertos em seios maxilares / Comparison between magnetic resonance imaging and cone beam computed tomography for the diagnosis of regions with grafts in the maxillary sinuses

Laurino, Fernando Antonio Reis 12 April 2019 (has links)
Uma das maneiras para corrigir a falta de volume ósseo em região posterior de maxila é o uso de enxertos ósseos para levantamento de assoalho de seio maxilar. O diagnóstico por imagem da região que recebeu o enxerto permite um planejamento cirúrgico preciso para a colocação de implantes dentários. Dentre os métodos descritos na literatura, a tomografia computadorizada por feixe cônico (TCFC), é uma técnica precisa para a obtenção de mensurações fiéis das dimensões do rebordo, e para avaliação da densidade mineral óssea (DMO). Recentemente, estudos têm demonstrado a técnica por imagem de ressonância magnética (RM) como uma técnica alternativa para avaliação da DMO também, além de apresentar a vantagem de não emitir radiação ionizante. No entanto, não existe um consenso na literatura sobre a diferença da precisão dos métodos descritos acima para diagnósticos clínicos de enxertos feitos em região de seio maxilar. Diante disso, o objetivo do presente estudo é comparar e correlacionar as medidas das dimensões obtidas de regiões enxertadas em seio maxilar de imagens de TCFC com as imagens de RM. / One of the ways to correct the lack of volume in a posterior plane of the jaw is the use of body grafts for lifting the maxillary sinus floor. Imaging of the region receiving the treatment allows for a precise surgical procedure for an association of dental implants. Among the methods in the literature, concomitant cone beam computed tomography (CBCT), is a precise technique for the application of resonance frequency measurements, and for the evaluation of bone mineral density (BMD). This study is a method for the evaluation of magnetic resonance imaging (MRI) in which an alternative technique for evaluation in the BMD also has an advantage of not emitting ionizing radiation. However, there is no consensus in the literature regarding the choice of the above schemes for clinical diagnoses of grafts made in the maxillary sinus region. Therefore, the present study is comparable and correlated with the images of grafted images in maxillary CBCT images with MRI images.
163

Avaliação da deformação média gerada nos intermediários e na região peri-implantar durante as etapas de confecção da prótese parcial fixa parafusada: análise com strain gauges / Evaluation of abutment and simulated bone tissue mean deformation around dental implants, during fabrication stages of screw-retained fixed partial prostheses: strain gauges analysis

Max Dória Costa 30 May 2011 (has links)
A adaptação passiva e estabilidade têm se tornado os dois pré-requisitos de maior importância na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi avaliar, com auxílio dos strain gauges ou extensômetros lineares elétricos, a deformação média ocorrida nos intermediários e na região peri-implantar mediante a instalação da infraestrutura parafusada durante sete etapas de confecção da prótese parcial fixa. Para a investigação, foi utilizado um modelo experimental homogêneo à base de poliuretano com dois implantes hexágono externo paralelos entre si. Sobre os implantes foram acoplados pilares Multi-unit de 5 mm de altura que receberam na sua superfície três strain gauges dispostos de maneira eqüidistante entre si. Também foram colados na superfície superior do bloco experimental quatro strain gauges para cada implante, posicionados nas faces mesial, distal, vestibular e lingual visando medir as tensões nestas áreas. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. As leituras foram realizadas em sete momentos, obtendo os valores médios de deformação no poliuretano e no intermediário respectivamente: 1) cilindros de cobalto-cromo pré-fabricados usinados como grupo controle (36,4µ&#x3B5; e 87,5µ&#x3B5;), 2) infraestrutura sobrefundida em monobloco com liga de níquel-cobalto-cromo (340,3µ&#x3B5; e 131,4µ&#x3B5;), 3) em seguida seccionada com espaço livre para solda (43,2µ&#x3B5; e 66,6µ&#x3B5;), 4) seccionada com espaço para solda preenchida com resina acrílica quimicamente ativada (Duralay) (74µ&#x3B5; e 86,8µ&#x3B5;), 5) seccionada e soldada (280µ&#x3B5; e 146,2µ&#x3B5;), 6) soldada com aplicação de cerâmica (288,7µ&#x3B5; e 151,1µ&#x3B5;) e 7) finalizada com aplicação do glaze, acabamento e polimento (359,9µ&#x3B5; e 197,8µ&#x3B5;). Estes resultados mostraram um aumento crescente da deformação média tanto nos intermediários como no poliuretano durante todas as etapas de confecção, com excessão da fundição em monobloco que atingiu altos valores, próximos da prótese finalizada. Desta forma, o procedimento de soldagem diminuiu os níveis de derformação, enquanto a aplicação da cobertura cerâmica, glaze, acabamento e polimento, aumentaram as deformações. / Passive fit and stability have become the most important prerequisites during the choice of materials and techniques to implant-supported prostheses. Therefore, the aim of this study was to verify the mean deformation in abutments and simulated bone tissue around dental implants, with the use of strain gages, during framework screw retention, analyzing seven fabrication stages of the fixed partial denture. For this research, an experimental model based on homogeneous polyurethane with two external hexagon implants parallel to each other, provided with 5 mm height multi-unit abutments. For each, abutment surface received three equidistant strain gauges and the experimental block received upper surface four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The tests were performed screwing the specimens on the abutment using an electronic torque with 10 Ncm maximum force. The readings were made in seven moments, with abutment and polyurethane mean deformation, respectively: 1) control group: cobalt-chromium prefabricated machined cylinder (36,4µ&#x3B5; e 87,5µ&#x3B5;), 2) framework fabricated by 1-piece method in nickel-cobalt-chromium alloy (340,3µ&#x3B5; e 131,4µ&#x3B5;), 3) framework sectioned with space for welding (43,2µ&#x3B5; e 66,6µ&#x3B5;), 4) weld space filled with chemically activated acrylic resin (Duralay) (74µ&#x3B5; e 86,8µ&#x3B5;), 5) framework sectioned and soldered (280µ&#x3B5; e 146,2µ&#x3B5;), 6) framework welded and ceramic application (288,7µ&#x3B5; e 151,1µ&#x3B5;) and 7) framework concluded applying glaze, finishing and polishing (359,9µ&#x3B5; e 197,8µ&#x3B5;). The results showed the mean strain increase in abutment and polyurethane over fabrication stages, except that framework fabricated by 1-piece method reached high values close to finished prostheses. Thus, the welding procedure decreased strain levels in simulated bone tissue around dental implants, while ceramic and glaze application, finishing and polishing procedures, increased strain.
164

Avaliação da influência da angulação do implante osseointegrado associado à prótese parcial removível classe I mandibular pelo método dos elementos finitos

Santos, Ciandrus Moraes de Freitas [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T19:16:56Z : No. of bitstreams: 1 santos_cmf_me_araca.pdf: 1084188 bytes, checksum: 0a96538ac84e5167cd37297d47e91a27 (MD5) / Universidade Estadual Paulista (UNESP) / A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Quando dessa associação, na instalação do implante, por motivos anatômicos ou diversos, o mesmo pode ser instalado com certa angulação. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e a tendência ao deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL), e da própria PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com diferentes angulações, localizado na distal do rebordo residual, atuando apenas como suporte para a base da prótese. Foram utilizados 6 modelos, os quais, em corte sagital, representam: Modelo A (MA) - hemiarco contendo o dente natural 33 somente e o rebordo alveolar distal; Modelo B (MB) - semelhante ao MA, com um PPREL convencional substituindo os dentes ausentes; Modelo C (MC) - semelhante ao anterior, com um implante verticalizado a 0o na região distal do rebordo, sob a base da prótese; Modelo D (MD) - semelhante ao MC, com o implante angulado a 5º para mesial; Modelo E (ME) - semelhante ao MD, com o implante angulado a 15º para mesial; Modelo F (MF) - semelhante ao ME, com o implante angulado a 30º para mesial. Com o auxílio do programa de elementos finitos ANSYS 8.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que: para a maioria das estruturas analisadas, quanto menor o ângulo do implante, menores as tensões observadas nos modelos; O MD (com implante a 5o) foi o que apresentou as melhores combinações de resultados, sendo portanto a melhor opção nas condições estudadas. / The prosthetic resolution of arches with free end saddles by association among removable partial denture and osseointegrated implants, still have a low use in dentistry clinic. This way, the purpose of this study was to evaluate, by the bidimensionsal finite element analysis, the tension distribution and the displacement tendency in the supporting structures of a free end removable partial denture (FERPD), and the own FERPD, associated to an osseointegrated implant of 10,0 x 3,75 mm (Bränemark System), located in the distal area of the free end saddle, acting solely as support for the prosthesis base. Six models in sagital cut were utilized. Such represented: Model A (MA) - hemi arch containing the inferior left canine and the free end saddle; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with a vertical implant (0o) in the distal of the free end saddle, under the prosthesis base; Model D (MD) - similar to the previous, with the implant in an angulation of 5° to the mesial; Model E (ME) - similar to the previous, with the implant in an angulation of 15°; Model F (MF) - similar to the previous, with the implant angulation of 30°. With the aid of the finite element analysis program ANSYS 8.0, the models were loaded with 50 N of vertical forces on each cuspid of the teeth. The maps analysis allowed conclude that: For the most of analyzed structures, as lower the implant's angle, the lower the observed tension in the models. The MD (implant at 5°) was the better results combination, being the best option in the studied conditions.
165

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos

Tabata, Lucas Fernando [UNESP] 05 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-05Bitstream added on 2014-06-13T20:37:56Z : No. of bitstreams: 1 tabata_lf_me_araca.pdf: 8309973 bytes, checksum: 5d726f976a2382ac0dc6e3d5eff78d89 (MD5) / Universidade Estadual Paulista (UNESP) / No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below)
166

Análise fotoelástica da tensão entre diferentes tipos de sistemas de retenção em próteses obturadoras palatinas implanto-retidas ou não e com ou sem reembasamento “soft”

Ribeiro, Paula do Prado [UNESP] 13 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-13Bitstream added on 2014-06-13T20:18:39Z : No. of bitstreams: 1 ribeiro_pp_me_araca.pdf: 1296460 bytes, checksum: 0aa88d770aee2b3e8787125e444deac4 (MD5) / O câncer da região de cabeça e pescoço é uma doença muito prevalente no Brasil, e as principais formas de tratamento são a cirurgia acompanhada ou não da radioterapia e quimioterapia. Perdas parciais ou totais de osso maxilar podem comprometer seriamente a fisiologia bucal causando sequelas como comunicações buconasosinosal. Neste caso, podese optar como forma de tratamento pela reabilitação protética com a aplicação de implantes osseointegrados. A literatura odontológica tem mostrado inúmeros trabalhos que avaliam a distribuição de forças com a finalidade de recolher melhores subsídios para o planejamento de próteses bucomaxilofaciais, que ainda é pouquíssimo explorada. Dentre os métodos utilizados, o da fotoelasticidade tem sido aceito, especialmente por permitir uma análise fiel da distribuição de forças. Assim, a proposta deste trabalho foi verificar a tendência de distribuição de forças e estresse, através do método fotoelástico, que incidem sobre diferentes tipos de sistemas de retenção em implantes (o’ring, barra clipe e o’ring/barra clipe) associado a próteses obturadoras palatinas implantoretidas e também em próteses obturadoras mucossuportadas (sem implante), utilizandose ou não de silicone com reembasamento direto (Sofreliner). O conjunto (prótese e modelo fotoelástico) foi posicionado em polariscópio circular e recebeu aplicação de carga de 100 N a velocidade de 10 mm/s no primeiro molar de cada prótese. Após as aplicações de carga houve a formação franjas correspondentes à tensão registrada. Então, as imagens foram transferidas para um computador e analisadas no programa ADOBE Photoshop. Ao se comparar os três sistemas de retenção das próteses obturadoras palatinas implantoretidas com a prótese mucossuportada (sem implantes), podese observar que as tensões foram distribuídas de forma mais homogênea... / The head and neck cancer is a very prevalent disease in Brazil and the main treatment is the surgery with or without radiation therapy and chemotherapy. Partial or total bone maxillary defects could involve seriously oral physiology causing consequences as buconasosinosal communications. In this case could be applied other option of treatment as prosthetic rehabilitation associated with osseointegrated implants. Scientific literature demonstrated countless studies that evaluate the force distribution with the aim to provide better subsidies for the planning of bucomaxillofacial prostheses, which still have few researches. Between the methodologies, the photoelastic method has been accepted; especially by allow an accurate analysis of the force distribution. Thus, the aim of this study was to verify the tendency of force distribution and the stress on different types of retention system (o’ring, clip bar and o’ring/clip bar) associated with palatal obturator prostheses with implant retention and conventional obturator prostheses (without implants), with or without silicone soft lining(Sofreliner), by means of photoelastic method. The set (prosthesis and photoelastic model) was located in circular polariscope and was applied a load of 100 load N at 10 mm/s on the first molar of each prostheses. After the load applications was registered the tension fringes. The images was transferred to a computer and analyzed at ADOBE Photoshop software. When compared the three retention systems of the palatal obturator prostheses and mucosupported prostheses (without implants), it can be observed that the stress was distributed more homogeneous and in lesser amount that the conventional prostheses, when compared to the other prostheses that presented implants and retention systems. With relation to stress distribution in the different retention systems, the bar clip... (Complete abstract click electronic access below)
167

Torque na instalação de implantes dentais pós-transplante de fíbula microvascularizado / Torque in the installation of dental implants in posttransplant microvascularized fibula

Maluf, Paulo Sérgio Zaidan [UNIFESP] 27 April 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-27 / INTRODUÇÃO: A reabilitação mastigatória com implantes dentais tornou-se, atualmente, uma terapêutica comum e necessária para pacientes edêntulos. Técnicas em implantodontia são aperfeiçoadas constantemente, dentre as quais o torque, para fixação dos cilindros de titânio em osso, considerado fundamental no prognóstico de sucesso da osteointegração. A reconstrução com retalhos microcirúrgicos, em ossos da face, tem sido cada vez mais realizadas em pacientes para reparação de sequelas pós-cirúrgicas. Para a completa reabilitação funcional desses pacientes é necessária a instalação de implantes osseointegráveis para o suporte de próteses dentais, mas inexistem pesquisas que determinem o torque necessário para estabilização inicial, desses implantes, em transplantes ósseos revascularizados. OBJETIVO: Mensurar o torque na instalação de implantes de titânio, em transplante de fíbula microrrevascularizado e consolidado, para reconstrução de maxila e mandíbula. MÉTODOS: Foram instalados 28 implantes dentais, em sete pacientes, com reconstrução cirúrgica em maxila e mandíbula por retalhos microcirúrgicos. No momento da instalação dos implantes mensurou-se o torque para estabilização final, cujos dados foram tabulados e analisados. RESULTADOS: O torque mínimo para instalação dos implantes foi de 20Ncm em 39,3% dos implantes, e o máximo de 45Ncm em 28,5%. CONCLUSÃO: A medida do torque no implante de titânio em transplante de fíbula microrrevascularizado, para reconstrução maxilomandibular, variou de 20 a 45Ncm, não tendo sido observada nenhuma influência relativamente ao gênero, à faixa etária e ao tempo de transplante. / INTRODUCTION: The masticatory rehabilitation with dental implants has become, a therapeutic technique for edentulous patients. Techniques in dental implant are constantly perfected, as the torque to fix the cylinders in a bone, considered fundamental in the prognosis of success in bone integration. The reconstruction with microsurgical flaps, in facial bones, has been increasingly performed in patients to repair the post-surgical sequelae. For the complete functional rehabilitation of these patients, the installation of bone integrable implants is necessary. With the objective of supporting the dental prosthesis, but there are no studies that determine the necessary torque to the initial stabilization of these dental implants in bone revascularized transplants. OBJECTIVE: To measure torque in installation of titanium implants, fibula microrevascularized and consolidated, in reconstruction of maxilla and mandibula. METHODS: Twenty eight dental implants were installed in seven patients with surgical reconstructions in the maxila and mandibular by microsurgical flaps. At the time of the installation of the implants, torque for final stabilization was measured, whose data were tabulated and analyzed. RESULTS: The minimum torque for installation of the implants was of 20Ncm in 39,3% of the implants, and the maximum, of 45Ncm in 28,5%. CONCLUSION: The measure of torque in implants of titanium of fibula microrevascularized transplants, for maxilomandibular reconstruction, varied from 20 to 45Ncm, and no influence related to gender, to age group or to time of transplant has been observed. / TEDE
168

Sobrevida de implantes submetidos à carga funcional imediata na região interforaminal através do uso de anéis de retenção isolados em uma prótese total removível / Survival rates of implants submited to immediate funcional load in the interforaminal region using retention rings on a removable complete denture

Renato da Silva Fraga 12 March 2009 (has links)
O presente trabalho teve como objetivo comparar clinicamente através da taxa de sobrevida e análise de freqüência de ressonância, dois implantes instalados na região anterior da mandíbula, submetidos à carga funcional imediatamente a instalação dos implantes, através de anéis de retenção isolados presos a uma sobredentadura, com um implante instalado na mesma região, livre de carga funcional. Com este objetivo, onze pacientes foram selecionados para instalação de três implantes osteointegráveis em cada, sendo o implante livre de cargas funcionais utilizado como grupo controle. Através dos resultados obtidos, dos vinte e dois implantes submetidos à carga funcional imediata, dois foram perdidos, apresentando uma taxa de sobrevida proporcional a amostra de 93.9%. Quanto ao grupo controle, nenhum implante foi perdido. Após 4 anos de controle clínico, todos os implantes apresentam-se osteointegrados. / The present study aimed to clinically compare through resonance frequency analysis and survival rate, one implant installed in the mandibular anterior region, free from functional load, with two implants installed in the same region, submitted to immediate functional load through isolated retention rings attached to an overdenture. With this purpose, eleven patients were selected for installation of three implants in each. The implants free from functional load were used as the control group. Through the obtained results, two implants of the twenty-two implants submitted to immediate functional load were lost, representing a survival rate of 93.9%. As for the control group, no implants were lost. After 4 years of clinical control all implants remained integrated.
169

Osseointegração de implantes usinados e oxidados em seio maxilar preenchido por coágulo com ou sem osso autógeno: estudo histológico, histométrico e de RFA em macacos

Palma, Vinícius Canavarros [UNESP] 28 November 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-11-28Bitstream added on 2014-06-13T20:01:38Z : No. of bitstreams: 1 palma_vc_dr_araca.pdf: 5314459 bytes, checksum: f4667d024f4919ee6a40de880d461e25 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo experimental foi comparar histologicamente o preenchimento do assoalho do seio maxilar por coágulo local com ou sem a associação de osso autógeno (controle), bem como investigar a osseointegração em duas diferentes superfícies de implante sob essas condições, através de medidas histométricas, análises histológicas e em freqüência de ressonância (RFA). Quatro macacos prego (tufted capuchin) tiveram todos os pré-molares e os primeiros molares superiores extraídos. Após quatro meses de reparo, os animais foram submetidos a cirurgia para acessar o assoalho do seio maxilar, através de uma janela óssea, para elevação da membrana do seio. O seio direito foi deixado para que se reparasse espontaneamente (somente coágulo), enquanto o esquerdo foi preenchido com enxerto ósseo autógeno. A membrana dos seios foram mantidas elevadas pela inserção simultânea de dois implantes (um usinado e outro oxidado eletroliticamente, Sistema Branemark®, Nobel Biocare) em cada lado da maxila. A estabilidade dos implantes foi acessada através da freqüência de ressonância (RFA, Ostell®) no momento da fixação dos implantes e no dia do sacrifício. Com a injeção de fluorocromos foi possível investigar o processo de neoformação óssea nos animais bem como relacioná-lo às diferentes superfícies dos implantes. Os animais foram sacrificados 6 meses após a cirurgia para análise histológica e de histomorfometria (contato-osso-implante - BIC, área de osso nas roscas - BA, e área de osso em um retângulo desenhado - BAR). Concluímos que não houve diferença entre o seio preenchido somente com coágulo local e o seio preenchido com osso autógeno, em relação à RFA, BIC, BA e BAR... / This experimental study aimed at comparing histologically the use of coagulum alone or autogenous bone graft (control) for sinus floor augmentation procedures as well as investigating the role played by implants surface on osseointegration under such circumstances, as measured by histological, histometric and resonance frequency analysis (RFA). Four tufted capuchin monkeys had all upper premolars and 1st molar extracted bilaterally. Four months later the animals underwent maxillary sinus floor augmentation surgery using the window technique. The right sinus was left to heal spontaneously (coagulum alone), whilst the left sinus was filled with autogenous bone graft. The Schneider's membrane was kept elevated by insertion of two implants (machined and oxidized, Bränemark System) in both sinuses. Implant stability was assessed through resonance frequency analysis (RFA, Osstell) at installation and at sacrifice. The pattern of bone formation in all experimental sites as well as related to the different implants surface was investigated using fluorochromes. The animals were sacrificed 6 months after MSFA for histology and histomorphometry (bone-to-implant contact - BIC, bone area in threads - BA, and bone area in rectangle - BAR). The results showed no difference between coagulum and bone graft sites regarding RFA, BIC, BA and BAR. As to BIC, the oxidized implants exhibited improved integration compared with machined ones. Oxidized implants showed higher BA compared to machined implants in bone grafts. The amount of bone tissue do not differ in coagulum alone and autogenous bone sites. Histologically, new bone is frequently deposited in contact with Schneider's membrane in coagulum alone sites, confirming the osseoinductive potential of the membrane. The oxidized implants should be preferred to machined implants in sinus floor augmentation procedures.
170

Análise experimental de copolímero na estabilidade primária de implantes osseointegráveis: avaliação microscópica em ratos

Kayatt, Fernando Esgaib [UNESP] 14 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-14Bitstream added on 2014-06-13T19:20:07Z : No. of bitstreams: 1 kayatt_fe_dr_araca.pdf: 743751 bytes, checksum: a6f9587cf07b5001b3dd1c88f814cb3e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Sin Implantes / A estabilidade primária na instalação de implantes dentários é uma das determinantes principais no processo de osseointegração. Algumas situações clínicas impossibilitam o travamento adequado do implante. A diástase provocada por sobrefresagem ou implantações pós-exodônticas indicam o uso de materiais para ocupar este espaço. O objetivo deste estudo foi analisar o uso de copolímero a base de ácido poliláctico na estabilidade primária de implantes osseointegráveis, realizando uma avaliação microscópica através de fluorocromos. Para isso, foram utilizados 14 cilindros de Ti cp GII instalados na tíbia de ratos, divididos em: Grupo Implante Travado (GIT) e Grupo Implante e Biomaterial (GIB), nos períodos de 7, 15 e 21 dias. Resultado: Os implantes suportaram 3N.cm de torque reverso e não foram encontradas diferenças estatisticamente significantes, nos períodos finais, entre as médias das áreas ao redor do implante. O copolímero de PLA/PGA proporcionou o posicionamento dos implantes e não obstou a deposição óssea. / The primary stability in the installation of dental implants is one of the main prerequisite in the osseointegration process. Some clinical situations disable the adequate stability of the implantation. A gap occurred between the bone and the implant provoked by overdrilling or tooth extractions sockets implantations indicates the use of biomaterials to occupy this space. The aim of this study was to analyze the use of PLA/PGA copolymer in the primary stability of osseointegrated implants, through removal torque test and a microscopic evaluation with fluorescent bone markers. For this, 14 cylinders of Ti cp GII had been installed in the tibia of rats, divided in: Group Implant with Stability (GIT) and Group Implant and Biomaterial (GIB), in the periods of 7, 15 and 21 days. Result: The implantations had supported 3N.cm of removal torque and had not been found differences statistically significant, in the final periods, between the averages of the areas of the periphery of the implants. The PLA/PGA copolymer kept the implants position and did not hinder the bone deposition.

Page generated in 0.1112 seconds