• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 26
  • 14
  • 10
  • 8
  • 5
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 170
  • 74
  • 61
  • 60
  • 46
  • 29
  • 26
  • 24
  • 24
  • 23
  • 22
  • 22
  • 19
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Determinação experimental de taxas de reação no 238U e 235U ao longo do raio da pastilha de UO2 do reator IPEN/MB-01 / Experimental determination of nuclear reaction rates in 238U and 235U along of the radius of fuel pellets of the IPEN/MB-01 reactor

Mura, Luís Felipe Liambos 06 November 2015 (has links)
Este trabalho apresenta e consolida uma metodologia alternativa para a determinação de taxas de reação nuclear ao longo da direção radial das pastilhas combustíveis sem necessidade de intensos fluxos neutrônicos. Esta técnica se baseia na irradiação de um disco de UO2 inserido no interior de uma vareta combustível desmontável no núcleo do reator IPEN/MB-01. Após a irradiação são realizadas várias espectrometrias gama do disco utilizando um detector HPGe alternando sequencialmente 6 colimadores de chumbo com diâmetros diferentes. Consequentemente, as reações nucleares de captura radiativa que ocorrem nos átomos de 238U, juntamente com as fissões que ocorrem em ambos 235U e 238U são mensuradas em função de 6 regiões radiais distintas do disco combustível. As correções de eficiência geométrica devido à introdução dos colimadores no sistema de detecção HPGe são determinadas através do código MCNP-5. As medidas de taxa de fissão são realizadas utilizando o 99Mo como radionuclídeo traçador. Esse radionuclídeo foi estudado e provou-se ideal para estas medidas por possuir um comportamento linear de formação, alto rendimento de fissão e principalmente por emitir fótons de baixa energia. As medidas foram efetuadas irradiando discos de UO2 (com enriquecimento de 4,3%) na posição central do reator IPEN/MB-01 a potência de 100 Watts durante uma hora. Algumas medidas foram realizadas utilizando uma luva de cádmio envolta na vareta combustível para determinar as taxas de reação nuclear na faixa de energia epitérmica. Os resultados experimentais obtidos são comparados a cálculos de taxa de reação nuclear via MCNP-5 utilizando a biblioteca de dados ENDF/B-VII.0, os quais apresentaram discrepâncias de no máximo 9% para as taxas de captura no 238U e 14% para as taxas de fissão no U na faixa epitérmica. Foram obtidos valores máximos de 4,5% para incertezas relativas as taxas de captura total e epitérmica e para as taxas de fissão total e epitérmica valores máximos de 11,3%. / This research presents and consolidates an alternative methodology for determining nuclear reaction rates along the radial direction of the fuel pellets which does not require high neutron flux. This technique is based on irradiating a thin UO2 disk inserted into a removable fuel rod at the IPEN/MB-01 reactor core. Several gamma spectrometries are performed after irradiation using a HPGe detector. Six lead collimators with different diameters are sequentially alternated during this process, thus, the nuclear radioactive capture which occurs in 238U and the fissions which occur in both 235U and 238U are measured according to six different radial regions of the fuel disk. Geometric efficiency corrections due to the introduction of collimators in HPGe detection system are determined by MCNP-5 code. The fission rate measurements are performed using the 99Mo. This radionuclide was studied and proved ideal for these measurements because it is formed in linear behavior in the reactor core, have a high yield fission and emits low-energy photons. Measurements were performed irradiating UO2 disks (with 4.3% enrichment) in the central position of the IPEN/MB-01 core at 100 watts power level during one hour. Some measurements were performed using a cadmium glove wrapped in the fuel rod to determine the nuclear reaction rates in the epithermal energy range. The experimental results obtained are compared with nuclear reaction rate calculations by means of MCNP-5 with ENDF/B-VII.0 data library showing discrepancies of up to 9% in 238U capture rates and 14% for U fission rates for epithermal energies. Uncertainties regarding the nuclear capture rates have maximum values of 4.5% and the fission rates has maximum values of 11.3%.
32

ETUDE DE L'IMPACT DU FILTRAGE ET DES NON-LINEARITES SUR LES SIGNAUX ULB DANS LES FRONT-END RADIO-FREQUENCE ET LES RESEAUX HYBRIDES OPTIQUE-RADIO

Lombard, Philippe 03 December 2007 (has links) (PDF)
Les systèmes Ultra Larges Bandes (ULB) représentent une nouvelle technologie de communication sans fil pour la transmission d'informations à très hauts débits. Avec une Densité Spectrale de Puissance (DSP) inférieure à -41.3 dBm/MHz, les distances de propagation sont considérablement restreintes (< 20 m). C'est en février 2002, que la commission fédérale de communication des Etats-Unis (FCC) a alloué pour les systèmes ULB une bande de fréquence comprise entre 3,1 et 10,6 GHz. Depuis, de nombreuses divergences sont apparues suivant les grandes zones géographiques de normalisation.<br />Au travers des nombreuses techniques de transmission ULB, nous étudions la modulation multi-bandes à répétition en fréquence orthogonale (MB-OFDM) qui a été proposée par l'European Computing Machineries Association (ECMA) en temps que standard en 2005.L'efficacité des signaux Impulsionnel Radio (IR), précurseur à l'ULB, a cependant été montrée. Nous présentons à ce titre une topologie originale nommée Multi-Bandes On-Off Keying (MB-OOK).<br />Dans le cadre de cette thèse, nous développons un outil de simulation système (SST) afin d'analyser les performances d'un système ULB-OFDM. Nous étudions l'influence sur le taux d'erreur binaire (BER) des non-linéarités du front-end de réception Radio-Fréquence (RF) et de l'amplification de puissance faible bruit (LNA) dans une chaîne de transmission globale.<br />Dans le cadre des systèmes MB-OOK, différents types de filtres sont envisagés. L'impact sur le BER est étudié afin de connaître les propriétés prédominantes des filtres sur les performances de transmission.<br />Le domaine de l'optique peut également être avantageusement employé dans des processus de transmission ULB. Les réseaux larges bandes radio sur fibres (RoF) présentent de nombreux intérêts pour fournir à moindre coût la distribution du signal mais également la possibilité de pouvoir le traiter directement. Dans ce sens, Nous évaluons les possibilités de convertir fréquentiellement des signaux de type ULB-OFDM, ainsi que d'évaluer l'impact de transmetteurs Electrique/Optique (E/O) sur les performances d'un système ULB sur fibre à partir des valeurs du vecteur d'erreur d'amplitude (EVM).
33

GnRH-Rezeptor-vermittelte Therapie des triple-negativen Mammakarzinoms / Targeted therapy for triple-negative breast cancers via GnRH receptor.

Föst, Crispin 27 August 2013 (has links)
Das triple-negative Mammakarzinom exprimiert weder Östrogen- noch Progesteronrezeptoren und es kommt zu keiner Überexprimierung des HER2-neu Gens. Daher haben bei diesem Subtyp des Mammakarzinoms spezifische Therapien, welche gezielt an diesen Rezeptoren wirken, keinerlei Nutzen. Etwa 60% aller Mammakarzinome exprimieren GnRH-Rezeptoren, welche als Ziel genutzt werden könnten. Der GnRH-Rezeptor kann für eine gezielte Chemotherapie mit zytotoxischen GnRH-Agonisten wie AN-152, bei welchem Doxorubicin an [D-Lys6]GnRH gebunden ist, genutzt werden. In der vorliegenden Arbeit habe ich in vitro als auch in vivo analysiert ob der zytotoxische GnRH-Agonist AN-152 Apoptose in triple-negativen Mammakarzinomzellen, welche GnRH-Rezeptoren exprimieren, induziert. Die GnRH-Rezeptorexpression in Tumorbiopsien triple-negativer Mammakarzinome wurde immunhistochemisch getestet. Die Zellproliferation wurde unter Verwendung des AlamarBlue®-Proliferationsassays analysiert. Die Apoptoseinduktion wurde durch die Bestimmung des mitochondrialen Membranpotentialverlustes quantifiziert. Die in vivo Experimente wurden mit Nackmäusen nach Xenotransplantation von humanen Brustkrebszellen durchgeführt. Wir konnten zeigen das die Behandlung triple-negativer aber GnRH-positiver MDA¬ MB 231, HCC 1806 und HCC 1937 Mammakarzinomzellen mit AN-152 in vitro zum apoptotischen Zelltod durch Aktivierung der Caspase-3 führt. Diese Antitumoreffekte konnten im Nacktmausmodell bestätigt werden. AN-152 inhibierte das Wachstum triple-negativer Mammakarzinomxenotransplantate in den Nacktmäusen komplett, ohne offensichtliche Nebenwirkungen. Der zytotoxische GnRH-Agonist AN-152 scheint ein passendes Medikament mit niedriger Toxizität für eine effiziente Therapie des triple-negativen Mammakarzinoms zu sein. (Föst C, Duwe F, Hellriegel M, Schweyer S, Emons G, Gründker C (2011). Targeted chemotherapy for triple-negative breast cancers via LHRH receptor. Oncol Rep, 25, 1481-7.)
34

Determinação experimental de parâmetros de Física de Reatores utilizando refletor de água pesada no Reator IPEN/MB-01 / Experimental determination of Reactor Physics parameters using heavy water reflector at the IPEN/MB-01 Research Reactor facility

Reinaldo de Melo Maeda 26 July 2012 (has links)
Este trabalho apresenta a realização de experimentos no reator nuclear IPEN/MB-01 submetido à presença de um refletor com água pesada instalado na sua face oeste. Após a instalação do refletor no reator foram conduzidos três tipos de experimentos: A calibração das barras de controle, a verificação da influência do aumento da temperatura do moderador na reatividade e a medição das taxas de reações por meio da irradiação de fios e folhas de ativação. Devido às propriedades nucleares de interação de nêutrons com água pesada, notadamente sua elevada capacidade de espalhamento e sua baixa capacidade de absorção, é possível notar alterações no funcionamento do reator observadas pelas mudanças dos padrões de retiradas e inserções de barras de controle no núcleo. Essas alterações são apresentadas no decorrer do trabalho. / This work presents the accomplishiment of experiments in the IPEN/MB-01 research nuclear under presence of a heavy water reflector installed in its western wall. After reflectors assembly in the reactor, three types of experiments were conducted: The control rod calibration, the check of temperature\'s influence increasing under reactivity and the measurement of reaction rates by means wires and foil\'s activation. Due to the properties of neutron interaction with heavy water, especially their high scattering and low absorption cross sections, pattern changes operation could be observed by the control rods moving inside the core. These observations will be the focus of this work
35

Calibração da potência do reator IPEN/MB-01 na configuração cilíndrica de menor excesso de reatividade obtida a partir da medida absoluta do fluxo médio de nêutrons / Power calibration of the IPEN/MB-01 reactor for the cylindrical configuration of minor reactivity excesso obtained from the measurements of the absolut average neutron flux

Alexandre Fonseca Póvoa da Silva 06 August 2014 (has links)
A ativação de folhas de ouro é uma das técnicas mais usadas para obter dados experimentais e assim comparar os resultados obtidos com aqueles calculados usando metodologias específicas e seus respectivos dados nucleares. Através da irradiação de folhas de ativação e posterior medida da atividade nelas induzida é possível determinar o fluxo de nêutrons no local da irradiação. O nível da potência de operação do reator é um parâmetro diretamente proporcional ao fluxo médio de nêutrons no núcleo do reator. O objetivo deste trabalho é obter, pela irradiação de folhas de ouro posicionadas simetricamente dentro do núcleo, utilizando a configuração cilíndrica que apresenta o menor excesso de reatividade, a potência gerada pela distribuição espacial do fluxo de nêutrons térmicos e epitérmicos no núcleo do reator IPEN/MB-01 e assim, calibrar seus canais nucleares. As folhas foram colocadas em uma placa de Lucite e irradiadas com e sem cobertura de cádmio, para se obter o valor absoluto de nêutrons térmicos e epitérmicos. A correlação entre a potência média do fluxo de nêutrons, como resultado da irradiação das folhas de ouro e, a potência média obtida a partir da aquisição de valores digitais dos canais nucleares, permite calibrar os canais nucleares do reator. Em 2008 foi feita a correlação para a configuração de núcleo retangular que resultou em uma calibração específica do nível de potência de operação para esta configuração geométrica de núcleo. Assim, esta calibração não pode ser utilizada como referência para a configuração em questão, ou seja, a cilíndrica, pois os parâmetros nucleares de distribuição de fluxo não são os mesmos, pois a distribuição difere para cada tipo de distribuição geométrica de núcleo. Além disto, o conhecimento preciso da potência de operação do reator nos permite obter os valores absolutos de fluxos de nêutrons e assim validar a metodologia de cálculo utilizada para este propósito. / The activation foils is one of the most used techniques to obtain nuclear parameters and thus compare the results with the calculated ones using specific methodologies and its nuclear data. Through the irradiation in the activation foils and ulterior measurement on its induced activity, it is possible to determine the neutron flux in the position where they were irradiated. The power level operation of the reactor is a parameter directly proportional to the average neutron flux in the core. The objective of this work is to obtain, by irradiating gold foils positioned symmetrically into the core for a cylindrical configuration, that presents the minor reactivity excess, the power generated through the spatial thermal and epitermal neutron flux distribution in the core of the IPEN/MB-01 Reactor, and thus calibrate its nuclear channels. The foils were put in a Lucite plate and irradiated with and without cadmium covered small plates, to obtain the absolute thermal and epithermal neutron flux. The correlation between the average power neutron flux, as a result of the gold foil´s irradiation and, the average power obtained by the digital values of the nuclear channels, allows the calibration of the nuclear channels of the reactor. This same correlation was done in 2008 with the reactor in a rectangular configuration, which resulted in a specific calibration of the power level operation for this geometric configuration of the core. Thus this calibration cannot be used as a reference for the actual configuration, the cylindrical one, because the nuclear parameters of the neutrons distribution are not the same, it changes for every geometric configuration of the core. Furthermore, the precise knowledge of the power neutron flux allows us to obtain absolute value of the neutron flux and thus validate the methodology used for this purpose.
36

Alterações eletrocardiográficas como preditores de gravidade no acidente vascular cerebral / Electrocardiographic abnormalities as predictors of stroke severity

Braga, Gabriel Pereira [UNESP] 01 March 2016 (has links)
Submitted by GABRIEL PEREIRA BRAGA null (gabrielbraga@yahoo.com) on 2016-12-02T09:58:55Z No. of bitstreams: 1 Tese Revisão FINAL.pdf: 8445004 bytes, checksum: 2e04918d8a1ac628b07d606003577ce5 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-12-05T20:00:36Z (GMT) No. of bitstreams: 1 braga_gp_dr_bot.pdf: 8445004 bytes, checksum: 2e04918d8a1ac628b07d606003577ce5 (MD5) / Made available in DSpace on 2016-12-05T20:00:36Z (GMT). No. of bitstreams: 1 braga_gp_dr_bot.pdf: 8445004 bytes, checksum: 2e04918d8a1ac628b07d606003577ce5 (MD5) Previous issue date: 2016-03-01 / Introdução: As doenças cerebrovasculares são causas maiores de morbimortalidade no Brasil e no mundo, sendo associadas a enormes custos biopsicossociais. As alterações eletrocardiográficas e cardíacas na fase aguda do acidente vascular cerebral são relacionadas com elevada mortalidade após estes eventos e grande debate existe sobre a gênese destas alterações nesta fase ictal. O eletrocardiograma é método diagnóstico não invasivo capaz de fornecer informações sobre fisiologia e processos patológicos do coração, incluindo eventual influência negativa exercida pelo sistema nervoso autônomo. Objetivo: O presente estudo objetiva avaliar se alterações eletrocardiográficas e enzimáticas na fase aguda do AVC são preditoras de desfecho desfavorável definido por pontuação na escala modificada de Rankin entre 3-6 em 90 dias do evento cerebrovascular. Métodos: Foi realizado estudo prospectivo, com pacientes atendidos no PS de Neurologia do HC-FMB, no período de março de 2012 a março de 2013, com até 24 horas de evolução de AVC, e excluídos aqueles com eventos cardíacos recentes. Foram coletados dados demográficos, história clínica, traçados de eletrocardiograma e dosagens de biomarcadores de necrose miocárdica obtidos na admissão. Associação entre tipo AVC e variáveis categóricas e numéricas foi analisada pelos testes de Fisher e Kruskal-Wallis seguido do teste de Dunn para comparações múltiplas, respectivamente. Associação entre alguma complicação geral ou cardíaca com chance de mau prognóstico neurológico e óbito foi analisada por regressão logística simples. Regressão logística corrigida para sexo, idade, controle da pressão arterial e complicações cardíacas foi utilizada na determinação da associação entre alterações eletrocardiográficas e mau prognóstico neurológico. Resultados: Foram analisados 112 pacientes, com idade de 69 (26 - 93) anos e maioria do sexo masculino. Pacientes com AVC hemorrágico apresentaram quadro clínico mais grave na entrada com NIHSS 20 (0 – 42). Não houve diferença em relação aos fatores de risco. Dos eletrocardiogramas avaliados, 71(63,3%) possuíam alguma anormalidade. As principais alterações foram fibrilação atrial, alterações de repolarização e achados sugestivos de isquemia miocárdica. Não houve diferença dos subtipos de AVC em relação aos níveis de marcadores de necrose miocárdica. Foi observado que 61(54,4%) apresentavam níveis de CKMB e 15(13,3%) níveis de troponina I acima do valor de referência. Análise multivariada evidenciou relação da fibrilação atrial (5,29 OR p=0,006 IC95% 1,6-17,5), frequência cardíaca (1,032 OR p=0,008 IC95% 1,008 – 1,056) e presença de alguma anormalidade no segmento ST (4,736 OR p=0,008 IC95% 1,496-14,988) com complicações cardíacas durante a internação. Aumentos no intervalo PR (1,037 OR p=0,002 IC95% 1,013-1,060), presença de anormalidades do segmento ST (3,457 OR p=0,038 IC95% 1,074 – 11,127) e anormalidade de onda T (7,244 OR p=0,001 IC95% 2,290 – 22,913) se relacionaram com maior grau de incapacidade em 90 dias. Elevações da troponina I (2,954 OR, p=0,039, IC95% 1,056 – 8,260), anormalidade do segmento ST (4,257 OR, p=0,028, IC95% 1,170 – 15,498), anormalidade de onda T (5,599 OR, p=0,014, IC95% 1,410 – 22,230), somatório de onda Q (1,3 OR, p=0,038, IC95% 1,014-1,667) se relacionaram com maior chance de óbito. A alteração do segmento ST que mais se relacionou com este desfecho foram as alterações do nivelamento de ST (OR 14,625 IC95% 2,120-100,909 p 0,006). Conclusões: Alterações eletrocardiográficas na fase aguda de doenças cerebrovasculares são frequentes e relacionadas a maior chance de mortalidade e maior grau de incapacidade em 90 dias. / Introduction: Cerebrovascular diseases are major causes of morbidity and mortality in Brazil and worldwide, being associated with huge biopsychosocial costs. Electrocardiographic and cardiac abnormalities in the acute phase of stroke are associated with high morbidity and mortality after these events and great debate exists about the genesis of these changes on ictal phase. The electrocardiogram is a noninvasive diagnostic method able to provide information about anatomy, physiology and pathological processes of the heart, including possible negative influence of the Autonomic Nervous System. Objective: This study aims to assess whether electrocardiographic and enzymatic alterations in the acute phase of stroke are predictors of unfavorable outcome defined by scores on the modified Rankin scale of 3- 6 within 90 days of the cerebrovascular event. Methods: A prospective study was conducted with patients treated at the HC-FMB Neurology ED, from March 2012 to March 2013, up to 24 hours of onset of stroke, and excluded those with recent cardiac events. Demographic data, medical history, electrocardiogram tracings and measurements of myocardial necrosis biomarkers obtained on admission were recorded. Association between stroke type and categorical and numerical variables was analyzed by Fisher and Kruskal-Wallis tests followed by Dunn’s test for multiple comparisons, respectively. Association between any general or cardiac complication and poor neurological outcome and mortality was analyzed by simple logistic regression. Multiple logistic regression adjusted for sex, age, blood pressure control and cardiac complications was used to determine the association between electrocardiographic abnormalities and poor neurological outcome. Results: 112 patients were analyzed, with a median age of 69 years-old (26 - 93) and mostly male. Hemorrhagic stroke patients had the most severe clinical picture at the entrance with NIHSS of 20 (0 - 42). There was no difference regarding to cardiovascular risk factors. Electrocardiographic abnormalities were found in 71(63.3%) patients. The main changes were rhythm disturbances (atrial fibrillation), repolarization changes and findings suggestive of myocardial ischemia. There was no difference in stroke subtype compared to the levels of myocardial necrosis markers. 61(54.4%) had CK-MB and 15(13.3%) troponin levels above the reference value. Multivariate analysis showed that atrial fibrillation (OR 5.29 p = 0.006 95% CI 1.6 to 17.5), heart rate (OR 1.032 p = 0.008 95% CI 1.008 to 1.056) and the presence of an abnormality in the ST segment (4,736 OR p = 0.008 95% CI 1.496 to 14.988) correlated with cardiac complications during hospitalization. Increases in PR interval (p = 0.002 95% CI 1.013 to 1.060 1,037OR), presence of ST-segment abnormalities (p = 0.038 OR 3.457 95% CI 1.074 to 11.127) and T wave abnormalities (p = 0.001 OR 7.244 95% CI 2.290 - 22.913) were related to a higher degree of disability in 90 days. Elevations of troponin (2,954 OR, p = 0.039, 95% CI 1.056 to 8.260), ST segment abnormality (4,257 OR, p = 0.028, 95% CI 1.170 to 15.498), wave abnormality t (5,599 OR, p = 0.014, 95 % 1.410 to 22.230), wave sum Q (OR 1.3, p = 0.038, 95% CI 1.014 to 1.667) were related to a higher likelihood of death. Abnormality of ST segment most associated with this outcome was the changes of ST leveling (OR 95% CI 2.120 to 100.909 14.625 p 0.006). Conclusions: We conclude that the electrocardiographic changes in acute cerebrovascular diseases are frequent and related to a higher chance of mortality and a greater degree of disability in 90 days.
37

ANESTESIA COM CETAMINA S(+) ASSOCIADA À ATROPINA E XILAZINA EM CÃES: AVALIAÇÃO CARDÍACA E BIOQUÍMICA SÉRICA / Ketamine anesthesia with S (+) AND ASSOCIATED to atropine Xylazine IN DOGS: EVALUATION heart and Biochemical Serum

FRANCO, Leandro Guimarães 05 March 2008 (has links)
Made available in DSpace on 2014-07-29T15:07:44Z (GMT). No. of bitstreams: 1 Leandro_Franco.pdf: 1233771 bytes, checksum: d1a3e21430ce8cb834c7bb95cd287196 (MD5) Previous issue date: 2008-03-05 / Changes in physiological parameters of electrocardiography, echocardiography and biochemistry markers were evaluated in dogs anesthetized with different associations of atropine, xylazine and S-ketamine. Twenty three healthy female dogs randomly distributed in four groups named as GI-6, GII-6, GIII-6 and GIV-5 were treated respectively with atropine and S-ketamine (0,04mg/kg; 10 mg/kg); S-ketamine (10 mg/kg); atropine, xylazine and S-ketamine (0,04mg/kg; 1,1 mg/kg; 10 mg/kg) and xylazine and S-ketamine (1,1 mg/kg; 10 mg/kg). Ten minutes after induction, 5mg/kg of S-ketamine was administered to animals from all groups. Measurements of electrocardiogram, echocardiogram and serum activity of aspartate aminotransferase (AST), creatine kinase (CK) and creatine kinase MB isoenzyme (CK-MB) were evaluated for 36 hours. Concerned to electrocardiography, the proposed anesthetic protocols showed significant changes especially in atrioventricular conduction period (PR interval) and systole period (QT interval), mostly in GIV. In relation to echocardiography, the main alterations happened in following variables, final stroke volume, ejection fraction and cardiac output, predominantly in GIV. In serum biochemistry analysis, it was observed alterations in CK and CK-MB values in all groups, which maintained changed for a longer time in GIII and GIV. Thus, under conditions of this study, it can be conclude that atropine, xylazine and S-ketamine association (GIII) determined lower effects on heart, while marking alterations occurred in animals from GIV / Avaliaram-se as alterações eletrocardiográficas, ecocardiográficas e de marcadores bioquímicos em cadelas anestesiadas com atropina-xilazina-cetamina-S (+) em diferentes associações. Utilizaram-se 23 cadelas, clinicamente saudáveis, distribuídas aleatoriamente em quatro grupos experimentais (GI-n=6, GII-n=6, GIII-n=6 e GIV-n=5). Os animais do GI, GII, GIII e GIV foram tratados respectivamente com atropina-cetamina-S (+) (0,04 mg/kg 10 mg/kg), cetamina-S (+) (10 mg/kg), atropina-xilazina-cetamina-S (+) (0,04mg/kg 1,1 mg/kg -10 mg/kg) e xilazina-cetamina-S (+) (1,1 mg/kg -10 mg/kg). Após dez minutos da aplicação da indução, foram reaplicados 5,0 mg/kg de cetamina-S (+) nos animais de ambos os grupos. Avaliaram-se os animais por um período de 36 horas, por meio de eletrocardiograma, ecocardiograma e avaliações da atividade sérica de aspartatoaminotransferase (AST), creatinoquinase (CK) e creatinoquinase fração-MB (CK-MB). Relativamente à eletrocardiografia, os protocolos anestésicos estudados desencadearam mudanças significativas especialmente no tempo de condução atrioventricular, evidenciado pelo aumento da duração do intervalo PR, e período de sístole, evidenciado pelo aumento da duração do intervalo QT, sugerindo um quadro de sobrecarga ventricular, predominantemente evidenciados nos animais do grupo tratado com a associação xilazina-cetamina-S (+). Quanto à avaliação ecocardiográfica, as principais alterações foram evidenciadas entre as variáveis, volume sistólico final, fração de ejeção e débito cardíaco, predominantemente nos animais xilazina-cetamina-S (+). Com relação à avaliação bioquímica, notou-se que independente do tratamento adotado foram observadas alterações nos valores de CK e CK-MB, permanecendo alteradas por um período maior nos animais dos grupos tratados com atropina-xilazina-cetamina-S(+) ou xilazina-cetamina-S (+). Desse modo, diante das condições em que o estudo foi realizado permite-se concluir que dentre os grupos estudados, a associação atropina-xilazina-cetamina-S (+) desencadeou menores efeitos sobre o coração, enquanto que as alterações mais significativas ocorreram nos animais tratados com xilazina-cetamina-S(+)
38

Caracterização dos campos neutrônicos obtidos por meio de armadilha de nêutrons no interior do núcleo do reator nuclear IPEN/MB-01 / Neutronic characterization of the fields obtained by means of neutron traps inside the nuclear reactor core IPEN/MB-01

Luiz Ernesto Credidio Mura 08 June 2011 (has links)
Este trabalho apresenta os resultados dos valores de fluxo de nêutrons obtidos a partir da implantação de uma armadilha de nêutrons no núcleo do Reator IPEN/MB-01. Foram analisadas várias configurações de armadilhas implantadas no núcleo do reator IPEN/MB-01 de forma a se eleger a armadilha mais eficiente. Para a caracterização energética, foram irradiados no centro da armadilha de nêutrons, detetores de ativação de vários materiais diferentes (Au, Sc, In, Ti, Ni). As respectivas espectrometrias gama desses elementos após a irradiação com e sem cobertura de cádmio, forneceram valores experimentais das taxas de reação nuclear (atividade de saturação) por núcleo alvo e as respectivas incertezas que servem de entrada ao código SANDBP que calculou o espectro de energia dos nêutrons no centro do Flux-Trap em 50 grupos de energia, utilizando-se dos espectros de entrada calculados na posição de irradiação (centro do \"Flux Trap\") por códigos de Física de Reatores. Os resultados obtidos constataram um aumento do fluxo de nêutrons térmico no centro da armadilha da configuração 203 em relação a configuração sem armadilha (padrão) da ordem de 350% sem contudo haver a necessidade de se aumentar a potência do reator. Foram também efetuadas comparações entre os espectros desdobrados obtidos pelo SANDBP, em relação aos calculados pelos códigos MCNP-4C e XSDRNPM. A caracterização espacial do fluxo de nêutrons térmicos é feita com folhas de ativação na forma de uma liga infinitamente diluída em massa de 1% de Au e 99% de Al em alguns pontos internos da configuração 203 (axialmente ao Flux Trap\" e adjacências radiais) e os resultados mostraram um aumento significativo da magnitude de seus valores quando comparados a configuração padrão retangular. / This paper presents the results of the neutron flux values obtained from the deployment of a Flux Trap of neutrons in the reactor core IPEN/MB-01. We analyzed several configurations of Flux Traps deployed in the reactor core IPEN/MB-01 in order to get elected to Flux Trap configuration more efficient. To characterize the neutron spectrum were irradiated in the center of the Flux Trap activation detectors of different materials (Au, Sc, In, Ti, Ni). The respective gamma spectroscopy of these elements after irradiation with and without cadmium cover, provided the experimental values of the nuclear reaction rates (saturation activity) by the target nuclei and their uncertainties used as input to the code SANDBP who calculated the energy spectrum of neutrons in the center of the \"Flux-Trap\" in 50 energy groups, using the input spectra calculated at the irradiation position (center of the \"Flux Trap\") by codes for Reactor Physics. The results found an increase in the thermal neutron flux in the center of the Flux Trap configuration 203 for the standard configuration (default) of about 350% without having the need to increase the reactor power. We also made comparisons between the spectra obtained by SANDBP deployed, compared to those calculated by MCNP-4C code and XSDRNPM. The spatial characterization of the thermal neutron flux is made with activation foils in the form of an infinitely dilute bulk alloy of 1% Au and 99% Al in some internal points of the configuration 203 (axially to Flux Trap \"and adjacent radial) and the results showed a significant increase in the magnitude of their values when compared to standard rectangular configuration.
39

Determinação experimental de taxas de reação no 238U e 235U ao longo do raio da pastilha de UO2 do reator IPEN/MB-01 / Experimental determination of nuclear reaction rates in 238U and 235U along of the radius of fuel pellets of the IPEN/MB-01 reactor

Luís Felipe Liambos Mura 06 November 2015 (has links)
Este trabalho apresenta e consolida uma metodologia alternativa para a determinação de taxas de reação nuclear ao longo da direção radial das pastilhas combustíveis sem necessidade de intensos fluxos neutrônicos. Esta técnica se baseia na irradiação de um disco de UO2 inserido no interior de uma vareta combustível desmontável no núcleo do reator IPEN/MB-01. Após a irradiação são realizadas várias espectrometrias gama do disco utilizando um detector HPGe alternando sequencialmente 6 colimadores de chumbo com diâmetros diferentes. Consequentemente, as reações nucleares de captura radiativa que ocorrem nos átomos de 238U, juntamente com as fissões que ocorrem em ambos 235U e 238U são mensuradas em função de 6 regiões radiais distintas do disco combustível. As correções de eficiência geométrica devido à introdução dos colimadores no sistema de detecção HPGe são determinadas através do código MCNP-5. As medidas de taxa de fissão são realizadas utilizando o 99Mo como radionuclídeo traçador. Esse radionuclídeo foi estudado e provou-se ideal para estas medidas por possuir um comportamento linear de formação, alto rendimento de fissão e principalmente por emitir fótons de baixa energia. As medidas foram efetuadas irradiando discos de UO2 (com enriquecimento de 4,3%) na posição central do reator IPEN/MB-01 a potência de 100 Watts durante uma hora. Algumas medidas foram realizadas utilizando uma luva de cádmio envolta na vareta combustível para determinar as taxas de reação nuclear na faixa de energia epitérmica. Os resultados experimentais obtidos são comparados a cálculos de taxa de reação nuclear via MCNP-5 utilizando a biblioteca de dados ENDF/B-VII.0, os quais apresentaram discrepâncias de no máximo 9% para as taxas de captura no 238U e 14% para as taxas de fissão no U na faixa epitérmica. Foram obtidos valores máximos de 4,5% para incertezas relativas as taxas de captura total e epitérmica e para as taxas de fissão total e epitérmica valores máximos de 11,3%. / This research presents and consolidates an alternative methodology for determining nuclear reaction rates along the radial direction of the fuel pellets which does not require high neutron flux. This technique is based on irradiating a thin UO2 disk inserted into a removable fuel rod at the IPEN/MB-01 reactor core. Several gamma spectrometries are performed after irradiation using a HPGe detector. Six lead collimators with different diameters are sequentially alternated during this process, thus, the nuclear radioactive capture which occurs in 238U and the fissions which occur in both 235U and 238U are measured according to six different radial regions of the fuel disk. Geometric efficiency corrections due to the introduction of collimators in HPGe detection system are determined by MCNP-5 code. The fission rate measurements are performed using the 99Mo. This radionuclide was studied and proved ideal for these measurements because it is formed in linear behavior in the reactor core, have a high yield fission and emits low-energy photons. Measurements were performed irradiating UO2 disks (with 4.3% enrichment) in the central position of the IPEN/MB-01 core at 100 watts power level during one hour. Some measurements were performed using a cadmium glove wrapped in the fuel rod to determine the nuclear reaction rates in the epithermal energy range. The experimental results obtained are compared with nuclear reaction rate calculations by means of MCNP-5 with ENDF/B-VII.0 data library showing discrepancies of up to 9% in 238U capture rates and 14% for U fission rates for epithermal energies. Uncertainties regarding the nuclear capture rates have maximum values of 4.5% and the fission rates has maximum values of 11.3%.
40

Experimentos no reator IPEN/MB-01 com refletores de aço inoxidável, aço carbono e níquel / IPEN/MB-01 reactor experiments with stainless steel, carbon steel, and nickel reflectors

Graciete Simoes de Andrade e Silva 30 January 2018 (has links)
Os experimentos com refletores nucleares de material pesado foram realizados no reator IPEN/MB-01 utilizando-se chapas de aço inoxidável, de aço carbono ou de níquel, num total de 32 chapas de cada material, inseridas adequadamente na face oeste do núcleo do reator. As chapas têm cerca de 3 mm de espessura. A largura e comprimento axial foram suficientes para cobrir todo o núcleo ativo do reator. Tais experimentos foram realizados com cada tipo de material refletor individualmente. Para cada etapa de colocação de chapas foram efetuadas medidas da reatividade devido à inserção destas no núcleo; bem como da posição crítica das barras de controle com BC1 e BC2 igualmente retiradas. Pôde ser observado que o aumento da absorção de nêutrons e consequente diminuição da moderação de nêutrons dominaram toda a física do problema quando foram inseridas poucas chapas de material refletor (cerca de 5 chapas para o aço inoxidável e aço carbono, e 3 chapas no caso do níquel). Na sequência, a reflexão de nêutrons tornou-se importante superando a absorção neutrônica; a reatividade aumentou até ultrapassar a situação sem chapa (excesso de reatividade zero) obtendo-se um acréscimo (ganho líquido) de reatividade com as 32 chapas inseridas (cerca de 162 pcm no caso do aço inoxidável, 37 pcm para o aço carbono e 295 pcm para o níquel). Portanto, observou-se que o núcleo refletido tornou-se mais reativo do que o núcleo sem material refletor. Resultados experimentais inéditos de medidas de reatividade foram obtidos com refletores de níquel. No que concerne a esse tipo de experimento não existe experimento similar na literatura internacional ao realizado no reator IPEN/MB-01. A análise teórica empregando o MCNP-5 e a biblioteca de dados nucleares ENDF/B-VII.0 evidenciou os aspectos físicos de absorção e reflexão de nêutrons nas chapas de material refletor considerados; entretanto apresentou uma discrepância quando a reflexão de nêutrons rápidos domina o fenômeno físico do transporte de nêutrons. Essas tendências foram encontradas independentemente do tipo de refletor pesado empregado nos experimentos. / Experiments with heavy-material nuclear reflectors were performed in the IPEN / MB-01 reactor using stainless steel, carbon steel or nickel plates, in a total of 32 plates of each material, properly inserted in the western face of the reactor core. The plates are about 3 mm thick. The axial width and length were sufficient to cover the entire active core of the reactor. Such experiments were performed with each type of reflective material individually. For each step of placement of plates were made measures of reactivity due to the insertion of these in the core; as well as the critical position of the BC1 and BC2 control rods also removed. It could be observed that the increase in neutron absorption and consequent decrease in neutron moderation dominated the whole physics of the problem when a few reflective material plates were inserted (about 5 plates for stainless steel and carbon steel and 3 plates for nickel). Subsequently, neutron reflection has become important overcoming neutron absorption; the reactivity increased until it exceeded the situation without plate (excess of zero reactivity) obtaining an increase (net gain) of reactivity with 32 inserts inserted (about 162 pcm in the case of stainless steel, 37 pcm for carbon steel and 295 pcm for nickel). Therefore, it was observed that the reflected core became more reactive than the core without reflective material. Unpublished experimental results of reactivity measurements were obtained with nickel reflectors. As for this type of experiment, there is no similar experiment in the international literature compared to the IPEN/MB-01 reactor. The theoretical analysis using the MCNP-5 together with nuclear data library ENDF/B-VII.0 evidenced the physical aspects of neutron absorption and reflection in the reflective material plates considered; however, it presented a discrepancy when the reflection of fast neutrons dominates the physical phenomenon of the transport of neutrons. These trends were found independently of the type of the heavy reflector employed in the experiments.

Page generated in 0.4162 seconds