• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 51
  • 12
  • 8
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 169
  • 169
  • 44
  • 38
  • 31
  • 23
  • 22
  • 20
  • 20
  • 19
  • 18
  • 17
  • 17
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Prótese valvar mitral : 20 anos de seguimento de uma amostra de pacientes operados no Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brasil

Ribeiro, Angela Henrique Silva January 2013 (has links)
Este estudo avalia mortalidade, reoperação e eventos hemorrágicos em pacientes submetidos à cirurgia para troca valvar mitral utilizando substituto biológico ou mecânico. O delineamento do estudo foi do tipo coorte histórica. Entre todos os registros, foram selecionados 352 prontuários de pacientes submetidos à cirurgia para troca valvar mitral entre 1990 e 2008, que tiveram seguimento mínimo de 5 e máximo de 23 anos. Para avaliar o tempo de sobrevida, a probabilidade de reoperação e de eventos hemorrágicos, foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste qui-quadrado de Log-rank. A análise multivariada de Regressão de Cox foi utilizada para identificar preditores independentes de mortalidade, reoperação e eventos hemorrágicos. A sobrevivência em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 87,7%, 74,2%, 69,3% e 69,3% e, para substituto biológico, foi de 87,6%, 71,0%, 64,2%, e 56,6%, respectivamente. Não houve diferença significativa entre a mortalidade entre os dois grupos (p=0,38). Na análise multivariada, os fatores associados com o óbito foram: idade, eventos hemorrágicos e insuficiência renal. A probabilidade de permanecer livre de reoperação em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 94,4%, 92,7%, 92,7% e 92,7% e, para bioprótese, foi de 95,9%, 86,4%, 81,2% e 76,5%, respectivamente (p=0.073), com uma incidência significativamente maior de reoperação para bioprótese (p=0,008). Os fatores associados com reoperação foram: sexo masculino, diâmetro da prótese e endocardite. A probabilidade de permanecer livre de eventos hemorrágicos em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 95,0%, 91,0%, 89,6% e 89,6% e, para bioprótese, foi de 96,9%, 94,0%, 94,0% e 94,0%, respectivamente (p=0,267). Os fatores associados com eventos hemorrágicos foram: IMC (índice de massa corporal) superior à 30 kg/m2, doença pulmonar obstrutiva crônica, tempo de ventilação mecânica na Unidade de Tratamento Intensivo superior a 30 dias e presença insuficiência mitral. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os dois grupos no seguimento; 2) houve tendência maior à reoperação no grupo com bioprótese; 3) após 10 anos de seguimento, a probabilidade de permanecer livre de reoperação não mudou para pacientes com substitutos valvares mecânicos; 4) a probabilidade de permanecer livre de eventos hemorrágicos não mudou após 10 anos de seguimento para portadores de biopróteses; 5) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 6) o tipo de prótese não foi fator preditor independente associado a nenhum dos desfechos avaliados na análise multivariada. / This study assessed mortality, reoperation and bleeding events in patients who underwent mitral valve replacement surgery with a biological or mechanical substitute. This was a historical cohort study. In total, 352 inpatients clinical health records who underwent mitral valve replacement surgery between 1990 and 2008 with 5 to 23 years of follow-up were selected. A Kaplan-Meier curve was used to evaluate the survival time, the probability of reoperation and bleeding events. A log-rank chi-square test was applied to compare the curves between groups. Multivariate Cox regression analysis was used to identify independent predictors of mortality, reoperation and bleeding events. The 5, 10, 15 and 20 year survival rates after surgery using a mechanical substitute were 87.7%, 74.2%, 69.3% and 69.3%, respectively, while the survival rates after surgery with a biological substitute were 87.6%, 71.0%, 64.2% and 56.6%, respectively. There was no significant difference in mortality between the two groups (p = 0.38). In the multivariate analysis, the factors associated with death were age, bleeding events and renal failure. The probabilities of being free of reoperation at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 94.4%, 92.7%, 92.7% and 92.7%, respectively, while after surgery with a bioprosthesis, they were 95.9%, 86.4%, 81.2% and 76.5%, respectively (p = 0.073); therefore, there was a significantly higher incidence of reoperation for patients receiving a bioprosthesis (p = 0.008). The factors associated with reoperation were male gender, diameter of the prosthesis and endocarditis. The probabilities of remaining free of bleeding events at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 95.0%, 91.0%, 89.6% and 89.6, respectively, while after surgery with a bioprosthesis, they were 96.9%, 94.0%, 94.0% and 94.0%, respectively (p = 0.267). The factors associated with bleeding events were BMI (body mass index) greater than 30 kg/m2, chronic obstructive pulmonary disease, mechanical ventilation at an Intensive Care Unit for longer than 30 days and mitral regurgitation. The authors concluded that: 1) mortality during follow-up was statistically similar in both groups; 2) there was a greater tendency to reoperation in the bioprosthesis group; 3) the probability of survival free from reoperation did not change for patients with mechanical valves after 10 years’ follow-up; 4) the probability of survival free from bleeding events did not change after 10 years’ follow-up for bioprostheses patients; 5) patients’ baseline characteristics were the greatest determinants of late mortality after mitral valve replacement surgery; 6) the type of prosthesis fitted was not an independent predictive factor of any of the outcomes analyzed in the multivariate analysis.
72

Prótese valvar mitral : 20 anos de seguimento de uma amostra de pacientes operados no Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brasil

Ribeiro, Angela Henrique Silva January 2013 (has links)
Este estudo avalia mortalidade, reoperação e eventos hemorrágicos em pacientes submetidos à cirurgia para troca valvar mitral utilizando substituto biológico ou mecânico. O delineamento do estudo foi do tipo coorte histórica. Entre todos os registros, foram selecionados 352 prontuários de pacientes submetidos à cirurgia para troca valvar mitral entre 1990 e 2008, que tiveram seguimento mínimo de 5 e máximo de 23 anos. Para avaliar o tempo de sobrevida, a probabilidade de reoperação e de eventos hemorrágicos, foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste qui-quadrado de Log-rank. A análise multivariada de Regressão de Cox foi utilizada para identificar preditores independentes de mortalidade, reoperação e eventos hemorrágicos. A sobrevivência em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 87,7%, 74,2%, 69,3% e 69,3% e, para substituto biológico, foi de 87,6%, 71,0%, 64,2%, e 56,6%, respectivamente. Não houve diferença significativa entre a mortalidade entre os dois grupos (p=0,38). Na análise multivariada, os fatores associados com o óbito foram: idade, eventos hemorrágicos e insuficiência renal. A probabilidade de permanecer livre de reoperação em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 94,4%, 92,7%, 92,7% e 92,7% e, para bioprótese, foi de 95,9%, 86,4%, 81,2% e 76,5%, respectivamente (p=0.073), com uma incidência significativamente maior de reoperação para bioprótese (p=0,008). Os fatores associados com reoperação foram: sexo masculino, diâmetro da prótese e endocardite. A probabilidade de permanecer livre de eventos hemorrágicos em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 95,0%, 91,0%, 89,6% e 89,6% e, para bioprótese, foi de 96,9%, 94,0%, 94,0% e 94,0%, respectivamente (p=0,267). Os fatores associados com eventos hemorrágicos foram: IMC (índice de massa corporal) superior à 30 kg/m2, doença pulmonar obstrutiva crônica, tempo de ventilação mecânica na Unidade de Tratamento Intensivo superior a 30 dias e presença insuficiência mitral. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os dois grupos no seguimento; 2) houve tendência maior à reoperação no grupo com bioprótese; 3) após 10 anos de seguimento, a probabilidade de permanecer livre de reoperação não mudou para pacientes com substitutos valvares mecânicos; 4) a probabilidade de permanecer livre de eventos hemorrágicos não mudou após 10 anos de seguimento para portadores de biopróteses; 5) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 6) o tipo de prótese não foi fator preditor independente associado a nenhum dos desfechos avaliados na análise multivariada. / This study assessed mortality, reoperation and bleeding events in patients who underwent mitral valve replacement surgery with a biological or mechanical substitute. This was a historical cohort study. In total, 352 inpatients clinical health records who underwent mitral valve replacement surgery between 1990 and 2008 with 5 to 23 years of follow-up were selected. A Kaplan-Meier curve was used to evaluate the survival time, the probability of reoperation and bleeding events. A log-rank chi-square test was applied to compare the curves between groups. Multivariate Cox regression analysis was used to identify independent predictors of mortality, reoperation and bleeding events. The 5, 10, 15 and 20 year survival rates after surgery using a mechanical substitute were 87.7%, 74.2%, 69.3% and 69.3%, respectively, while the survival rates after surgery with a biological substitute were 87.6%, 71.0%, 64.2% and 56.6%, respectively. There was no significant difference in mortality between the two groups (p = 0.38). In the multivariate analysis, the factors associated with death were age, bleeding events and renal failure. The probabilities of being free of reoperation at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 94.4%, 92.7%, 92.7% and 92.7%, respectively, while after surgery with a bioprosthesis, they were 95.9%, 86.4%, 81.2% and 76.5%, respectively (p = 0.073); therefore, there was a significantly higher incidence of reoperation for patients receiving a bioprosthesis (p = 0.008). The factors associated with reoperation were male gender, diameter of the prosthesis and endocarditis. The probabilities of remaining free of bleeding events at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 95.0%, 91.0%, 89.6% and 89.6, respectively, while after surgery with a bioprosthesis, they were 96.9%, 94.0%, 94.0% and 94.0%, respectively (p = 0.267). The factors associated with bleeding events were BMI (body mass index) greater than 30 kg/m2, chronic obstructive pulmonary disease, mechanical ventilation at an Intensive Care Unit for longer than 30 days and mitral regurgitation. The authors concluded that: 1) mortality during follow-up was statistically similar in both groups; 2) there was a greater tendency to reoperation in the bioprosthesis group; 3) the probability of survival free from reoperation did not change for patients with mechanical valves after 10 years’ follow-up; 4) the probability of survival free from bleeding events did not change after 10 years’ follow-up for bioprostheses patients; 5) patients’ baseline characteristics were the greatest determinants of late mortality after mitral valve replacement surgery; 6) the type of prosthesis fitted was not an independent predictive factor of any of the outcomes analyzed in the multivariate analysis.
73

Avaliação pré e pós-operatória, através de ressonância magnética cardiovascular, de pacientes com insuficiência da valva mitral submetidos à plástica mitral pela técnica do duplo teflon / Preoperative and postoperative evaluation, by cardiovascular magnetic resonance, of patients with mitral valve insufficiency submitted to mitral valve repair using the double teflon technique

Abdouni, Ahmad Ali 21 January 2019 (has links)
Introdução: A plástica valvar mitral é o tratamento de escolha no tratamento da insuficiência mitral de etiologia degenerativa. Estudos recentes têm demonstrado que a utilização de anéis protéticos na plástica mitral altera a dinâmica do anel mitral e do fluxo intraventricular, podendo levar a disfunção ventricular esquerda. Entretanto, a literatura é escassa em relação à morfologia e à dinâmica do anel mitral após a plástica mitral sem a utilização de anéis protéticos, e a ressonância magnética cardiovascular (RMC) é uma ferramenta que pode ser utilizada na avaliação do anel mitral e do remodelamento do átrio e do ventrículo esquerdo. Objetivo: Avaliar as alterações morfofuncionais, a dinâmica do anel mitral e o remodelamento do átrio e ventrículo esquerdo, por meio da RMC, em indivíduos portadores de insuficiência mitral de etiologia degenerativa, submetidos ao tratamento cirúrgico da valva mitral com a técnica do \"Duplo Teflon\". Métodos: No período de julho de 2014 a agosto de 2016, foram selecionados 36 pacientes consecutivos, com insuficiência mitral de etiologia degenerativa e prolapso da cúspide posterior. Três pacientes foram submetidos à troca valvar mitral e quatro não realizaram a RMC, de modo que 29 pacientes foram incluídos no protocolo e fizeram o seguimento proposto. Destes, 17 pacientes eram do sexo masculino (58,6%) e 12 do sexo feminino (41,4%), com idade média de 63,3 anos. Em relação à classe funcional (CF - NYHA), um paciente encontrava-se em CF I (3,4%), 5 pacientes em CF II (17,3%), 19 pacientes em CF III (65,5%) e 4 pacientes em CF IV (13,8%) no período pré-operatório. Os pacientes realizaram o exame de RMC no período pré-operatório, pós-operatório imediato (até 30 dias), 6 meses, um ano e dois anos após a cirurgia, utilizando um protocolo específico para avaliação da valva mitral. Foram obtidas as medidas da circunferência, dos diâmetros e da área do anel mitral em diferentes fases do ciclo cardíaco (diástole, sístole inicial, sístole média e sístole final). Foi analisado o remodelamento cardíaco, sendo utilizados como parâmetros as dimensões, volumes e fração de ejeção do átrio esquerdo e do ventrículo esquerdo, sendo os volumes indexados pela superfície corpórea. Utilizamos o teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante P < 0,05. Resultados: Houve um óbito hospitalar (3,4%). Com dois anos de seguimento, houve significativa melhora da classe funcional (CF), com 18 pacientes em CF I (75%) e 6 em CF II (25%). Após dois anos, 18 pacientes apresentam insuficiência mitral discreta ou ausente (75%) e dois pacientes (8,3%) apresentam insuficiência mitral importante, um deles relacionado ao implante de marcapasso no pós-operatório tardio. Observamos uma redução significativa em todas as medidas da valva mitral. A média da circunferência sistólica do anel mitral foi reduzida de 13,28 ± 1,95 para 11,5 ± 1,59 cm e a circunferência diastólica foi reduzida de 12,51 ± 2,01 para 10,66 ± 2,09 cm no período pós-operatório imediato, medidas que se mantiveram estáveis após 2 anos (P < 0,001). A média da área máxima do anel mitral no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos foi 14,34 ± 4,03 cm, 10,72 ± 2,81 cm, 10,92 ± 3,03 cm, 10,98 ± 3,45 cm, 10,45 ± 3,17 cm, respectivamente. A média da área mínima do anel mitral no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos foi de 12,53 ± 3,68 cm2, 9,60 ± 2,44 cm2, 9,66 ± 2,9 cm2, 9,60 ± 3,73 cm2 , 9,23 ± 2,84 cm2, respectivamente. Houve uma redução significativa desses parâmetros no seguimento de dois anos (p < 0,001), e essa redução foi maior no diâmetro ântero-posterior do que no diâmetro médio-lateral. A contração ou variação da área valvar mitral durante o ciclo cardíaco foi de 23,31 ± 9,04%, 19,63 ± 7,01%, 23,75 ± 8,09%, 25,75 ± 11,27%, 22,66 ± 9,77% respectivamente no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos, sem diferença estatística (p = 0,572), o que significa que a contratilidade do anel foi preservada após a cirurgia. Observamos redução dos volumes ventriculares e atriais esquerdos no seguimento, sendo mais significativa a redução do índice do volume diastólico final do ventrículo esquerdo. Conclusão: Observamos uma redução significativa do anel mitral após a cirurgia, em todas as medidas obtidas, com estabilidade da plástica mitral em 2 anos de seguimento e preservação da contração dinâmica do anel neste período / Introduction: Mitral valve repair is the treatment of choice for mitral regurgitation of degenerative etiology. Recent studies have shown that the use of prosthetic rings in mitral valve repair alters the dynamics of the mitral annulus and intraventricular flow, which may lead to left ventricular dysfunction. However, the literature is scarce in relation to the morphology and dynamics of the mitral annulus after mitral repair without the use of prosthetic rings, and cardiovascular magnetic resonance (CMR) is a tool that can be used in the evaluation of the mitral annulus and the remodeling of the left atrium and left ventricle. Objective: To evaluate the morphological changes and the dynamics of the mitral valve and the remodeling of the left atrium and left ventricle, by CMR, in patients with mitral insufficiency of degenerative etiology who underwent mitral valve surgery with the Double Teflon technique. Methods: From July 2014 to August 2016, 36 consecutive patients with mitral insufficiency of degenerative etiology and prolapse of the posterior leaflet were selected. Three patients underwent mitral valve replacement and four did not perform the CMR, so that 29 patients were included in the protocol and did the proposed follow-up. Of these, 17 patients were male (58.6%) and 12 were female (41.4%), with a mean age of 63.3 years. In relation to functional class (NYHA), one patient was in Class I (3.4%), 5 patients in Class II (17.3%), 19 patients in Class III (65.5%) and 4 patients in Class IV (13.8%) in the preoperative period. Patients underwent CMR examination in the preoperative period, immediate postoperative (up to 30 days), 6 months, one year and two years after surgery, using a specific protocol for mitral valve evaluation. Measurements of the circumference, diameters and mitral ring area were obtained in different phases of the cardiac cycle (diastole, initial systole, mean systole and final systole). Cardiac remodeling was analyzed, and the dimensions, volumes and ejection fraction of the left atrium and left ventricle were used as parameters, and the volumes were indexed by the body surface. We used the analysis of variance of repeated measures for the statistical analysis, being considered statistically significant P < 0.05. Results: There was one hospital death (3,4%). After two years of follow-up, there was a significant improvement in functional class, with 18 patients in Class I (75%) and 6 in Class II (25%). After two years, 18 patients had mild or absent mitral insufficiency (75%) and two patients (8.3%) had important mitral regurgitation, one of them related to late postoperative pacemaker implantation. We observed a significant reduction in all measures of the mitral valve. The mean systolic circumference of the mitral annulus was reduced from 13.28 ± 1.95 to 11.5 ± 1.59 cm and the diastolic circumference was reduced from 12.51 ± 2.01 to 10.66 ± 2.09 cm in the immediate postoperative period, measures that remained stable after 2 years (P < 0.001). The mean maximal area of the mitral annulus in the preoperative, immediate postoperative, 6 months, 1 year and 2 years was 14.34 ± 4.03 cm, 10.72 ± 2.81 cm, 10.92 ± 3,03 cm, 10.98 ± 3.45 cm, 10.45 ± 3.17 cm, respectively. The mean minimal area of the mitral annulus in the preoperative, immediate postoperative, 6 months, 1 year and 2 years was 12.53 ± 3.68 cm2, 9.60 ± 2.44 cm2, 9.66 ± 2.9 cm2, 9.60 ± 3.73 cm2, 9.23 ± 2.84 cm2, respectively. There was a significant reduction of these parameters at two-year follow-up (p < 0.001), and this reduction was greater in the antero-posterior diameter than in the midlateral diameter. The contraction or variation of the mitral valve area during the cardiac cycle was 23.31 ± 9.04%, 19.63 ± 7.01%, 23.75 ± 8.09%, 25.75 ± 11.27%, 22.66 ± 9.77% respectively in the preoperative, postoperative, 6 months, 1 year and 2 years, without statistical difference (p = 0.572), which means that the contractility of the ring was preserved after surgery. We observed reduction of left ventricular and left atrial volumes in the follow-up, being more significant the reduction of the left ventricle end-diastolic volume index. Conclusion: We observed a significant reduction of the mitral annulus after surgery, in all the measurements obtained, with stability of the mitral repair in 2 years of follow-up and preservation of the dynamic contraction of the ring in this period
74

Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon technique

Guedes, Marco Antonio Vieira 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
75

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Pinto, Nathali Cordeiro 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy
76

Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon technique

Marco Antonio Vieira Guedes 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
77

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Nathali Cordeiro Pinto 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy
78

Der Einfluss der Lernkurve auf die Ergebnisse der perkutanen Mitralklappenrekonstruktion mit MitraClip® in einer unizentrischen Kohorte von 75 chirurgischen Hochrisikopatienten / Impact of the learning curve on outcomes after percutaneous mitral valve repair with MitraClip® and lessons learned after the firtst 75 consecutive patients

Weicken, Ninja Maria 19 June 2012 (has links)
No description available.
79

Použití metod dobývání znalostí v oblasti kardiochirurgie / Application of knowledge discovery methods in the field of cardiac surgery

Čech, Bohuslav January 2014 (has links)
This theses demonstrate practical use of knowledge discovery in the field of cardiac surgery. The tasks of the Department of Cardiac Surgery University Hospital Olomouc are solved through the use of GUHA method and LISp-Miner system. Mitral valve surgery data comes from clinical practice between the years 2002 and 2011. Theoretical part includes chapter on KDD -- type of tasks, methods and methodology and chapter on cardiac surgery -- anatomy and functions of heart, mitral valve disease and diagnostic methods including quantification. Practical part brings solutions of the tasks and whole process is described in the spirit of CRISP-DM.
80

Die Rolle der intraoperativen Echokardiographie bei herzchirurgischen Operationen mit Schwerpunkt Mitralklappenrekonstruktion

Ender, Jörg 26 November 2012 (has links)
Die vorliegende Arbeit beschreibt die Rolle der intraoperativen transösophagealen Echokardiografie während herzchirurgischer Eingriffe mit Schwerpunkt Mitralklappenrekonstruktion. Ziel ist die Beschreibung der Aufgaben und Möglichkeiten dieses Verfahrens im klinischen Alltag und das Aufzeigen möglicher neuer Einsatzgebiete, wie die bildgestützte Größenbestimmung der Annuloplastieringe. Die intraoperative Echokardiografie hat sich seit den Anfängen in den achtziger Jahren des letzten Jahrhunderts zu einem Standardverfahren während herzchirurgischer Eingriffe entwickelt. Sie dient zum einen zur kardialen Diagnostik und zum anderen als Monitorverfahren. Trotz in der Regel gut vordiagnostizierter Patienten führt die intraoperativ durchgeführte transösophageale Echokardiografie während herzchirurgischer Eingriffe nicht selten zur Diagnose vorher nicht bekannter Pathologien und somit zu einer Änderung im chirurgischen Vorgehen. Speziell während der Mitralklappenrekonstruktion ermöglicht diese Methode die Diagnostik und Lokalisation der pathologischen Segmente, die Bestätigung des Schweregrades und dem Erkennen möglicher Risikofaktoren. Hierfür ist jedoch eine umfassende, standardisierte Untersuchung notwendig. Der Einsatz moderner Operationstechniken, wie z.B. der kathetergestützten Implantation der Aortenklappe ohne Einsatz der Herz-Lungen-Maschine, ohne Eröffnung des Sternums, macht eine direkte visuelle Einschätzung der Herzfunktion unmöglich. Sowohl zur Evaluierung der Herzfunktion als auch zur Größenbestimmung der zu implantierenden Klappenprothesen ist ein bildgebendes Verfahren unabdingbar. Die dreidimensionale transösophageale Echokardiografie ermöglicht nun in Echtzeit die komplette Darstellung z.B. der Mitralklappe. Dies erleichtert nicht nur die Verständigung zwischen Echokardiographeur und Chirurgen bei der Darstellung der Befunde, sondern ermöglicht nun erstmals auch die bildgestützte Planung des operativen Vorgehens, wie, z.B. die Visualisierung und Größenbestimmung der zu implantierenden Annuloplastieringe, die als Computermodelle auf die dreidimensionale Darstellung der Mitralklappe projiziert werden können. In der postoperativen TEE-Untersuchung ist die Evaluierung des rekonstruierten Mitralklappenapparates, die Quantifizierung einer eventuell bestehenden residualen Mitralinsuffizienz, sowie deren genaue Lokalisation primäres Ziel. Weiterhin sollten iatrogen aufgetretene Komplikationen in einer umfassenden postoperativen TEE-Untersuchung diagnostiziert werden wie z.B. der Verschluss des Ramus circumflexus, Aortendissektion, etc. Zusammenfassend wird in dieser Habilitationsarbeit die Rolle der intraoperativen Echokardiografie bei herzchirurgischen Eingriffen dargestellt. Ein besonderer Schwerpunkt in dieser Arbeit ist die transösophageale Echokardiographie bei Mitralklappenoperationen im Hinblick auf die Darstellung der bestehenden Pathologie, der Quantifizierung der Mitralinsuffizienz und dem Erkennen bestehender Risikofaktoren präoperativ bzw das Erkennen der Komplikation postoperativ.:1. Einführung in die Thematik 5 1.1. Einführung 5 1.2. Grundlage der vorliegenden Habilitationsarbeit 5 1.3. Intraoperative Echokardiografie in der Kardioanästhesie 5 1.4. Intraoperative Echokardiografie bei chirurgischer Mitralklappenrekonstruktion 8 1.5 .Die dreidimensionale transösophageale Echokardiographie zur bildgestützten Größenbestimmung des Annuloplastieringes während Mitralklappenrekonstruktion 9 2. Habilitationsschrift 11 2.1. Geschichte der Echokardiographie 11 2.2. Geschichte der Entwicklung der transösophagealen Echokardiographie 11 2.3. Einsatz der intraoperativen transösophagealen Echokardographie 12 2.3.1 Eigene Arbeit im Original: 13 2.3.2. Eigene Arbeit im Original 13 2.3.4. Echokardiographische Kontrolle von mechanischen Unterstützungssystemen 14 2.3.5. Transösophageale Echokardiografie bei kathetergestützter Aortenklappen- Implantation 15 2.3.5.1. Eigene Arbeit im Original: 16 2.3.5.2. Eigene Arbeit im Original: 16 2.3.6. Einfluss der intraoperativen Echokardiografie bei herzchirurgischen Eingriffen. 17 2.3.6.1. Eigene Arbeit im Original: 17 2.3.6.2. Eigene Arbeit im Original: 18 2.4. Intraoperative Echokardiographie bei Mitralklappenrekonstruktion 20 2.4.1. Einführung 20 2.4.2. Aufgabe der intraoperativen Echokardiographie bei Mitralklappenrekonstruktion 20 2.4.2.1. Beurteilung der Morphologie und Funktion des Mitralklappenapparates 21 2.4.2.1. Eigene Arbeit im Original: 30 2.4.2.2. Erkennen der Ursachen der Mitralinsuffizienz 31 2.4.2.2.1. Eigene Arbeit im Original: 34 2.4.2.2.2 Eigene Arbeit im Original: 35 2.4.2.3. Bestimmung des Schweregrades der Mitralinsuffizienz mittels intraoperativer Echokardiografie 36 2.4.2.4. Beurteilung der systolischen Funktion bei vorhandener Mitralinsuffizienz 38 2.4.2.4.1. Hilfestellung bei der chirurgischen Planung 39 2.4.2.4.2. Eigene Arbeit im Original: 39 2.4.2.4.3. Eigene Arbeit im Original: 40 2.4.2.4.4 Eigene Arbeit im Original: 41 2.4.3. Die dreidimensionale transösophageale Echokardiographie zur bildgestützten Größenbestimmung des Annuloplastieringes während Mitralklappenrekonstruktion 42 2.4.3.1. Eigene Arbeit im Original: 43 2.4.3.2. Eigene Arbeit im Original: 44 2.4.4. Postoperative TEE- Untersuchung 45 2.4.4.1. Darstellung des Ramus circumflexus 45 2.4.4.2. Kontrolle der Entlüftung des Herzens 45 2.4.4.3. Detektion einer residualen Mitralinsuffizienz 45 2.4.4.4 Ausschluss einer Mitralstenose 46 3. Erklärung über die eigenständige Anfertigung der Habilitationsschrift 62 Lebenslauf 63 Danksagung 65

Page generated in 0.4415 seconds