Spelling suggestions: "subject:"moisture content"" "subject:"moisture ccontent""
141 |
Some Aspects of Foamed Bitumen TechnologyNamutebi, May January 2011 (has links)
Although foamed bitumen has been widely applied in pavement construction some of its aspects are still not yet understood. In this study, some of these aspects including: effects of the foaming process on binder chemistry, characterization of foamed bitumen and development of a rational method to optimize foam characteristics, evaluation of aggregate particle coating within foamed bitumen treated materials, and development of a gyratory compaction procedure for laterite gravels treated with foamed bitumen were addressed. The effects of the foaming process on bitumen chemistry were investigated using Fourier transform infrared spectroscopy techniques. Also, foam characteristics of three binders were established and a rational method to optimize foam characteristics proposed. Aggregate particle coating with foamed bitumen was studied using the concepts of surface energy and Rice density. In addition a gyratory laboratory compaction procedure for laterite gravels treated with foamed bitumen was established using the modified locking concept. Infrared techniques have shown that foaming does not cause any changes in the binder chemistry, suggesting that foaming may be a physical process. Further, foam characteristics are greatly influenced by binder viscosity. Also, the equiviscous temperature seems to produce foam with optimum foam characteristics. Rice density results showed that aggregate size fraction, binder expansion ratio and viscosity influenced aggregate particle coating. Surface energy results revealed that foamed bitumen exhibited better coating attributes than neat bitumen. A new compaction procedure for laterite gravels treated with foamed bitumen based on the modified locking point was developed. / QC 20110427
|
142 |
Pavement behaviour evaluation during spring thaw based on the falling weight deflectometer methodSveinsdóttir, Berglind Ösp January 2011 (has links)
The bearing capacity of a road decreases greatly during spring thaw, when the previously frozen road begins to thaw. The extent of this decrease can be evaluated by making Falling Weight Deflectomter (FWD) measurements on the road, measuring the deflection of the road when an impact load is applied to it. The bearing capacity of the road can then be evaluated by backcalculating the layer modules with backcalculation programs, or through more simple calculations based on the deflection basin indices. Both analyses were carried out in this thesis with data from FWD measurements which were carried out on county road Lv 126 in Southern Sweden during the year 2010. The temperature and moisture content of the road were monitored during the same time. The aim with the thesis was to compare the two ways of analyses, and to find out if there is some relationship between them and the measured environmental data. The results showed that the base course layer and subbase decreased in stiffness during spring thaw about 50% while the decrease in the subgrade was 20%, compared to the backcalculated summer and autumn value. The results of the simple calculations from the deflection basin indices were well comparable to the backcalculation results. By comparing the backcalculated stiffness values to the moisture content measurements it was stated that the stiffness decreased as the moisture content increased.
|
143 |
The Effects of Material Properties in Saw Chain Cutting Efficiency Tests : Investigating the repeatability of cutting efficiency testsÖdvall, Petter, Ivarsson, Jakob January 2023 (has links)
Manufacturers of saw chains continuously strive to increase the performance of their products by reducing cutting times and minimising the energy consumption required for cutting. However, the evaluation process through testing is problematic as several uncontrollable factors impact the results. A large source of uncontrollable factors is the material used as a workpiece. Historically, wood has been used as a workpiece material since it is often what the end user will use it for. As a natural material, each stem contains a unique structure and can have a high variation in mechanical properties. Consequently, the analysis of older cutting efficiency is problematic since the result is linked to the specific stem being sawn, which is destroyed during the testing process. The current work aims to improve the repeatability of these tests by increasing the understanding of which material characteristics and material properties impact the variance during cutting efficiency measurements. An experiment was performed using pine as a workpiece material. It was found that the wood structure, density and hardness or moisture content could explain approximately 80% of the variation in the final tests. A more homogeneous material polyethylene was used to explore if a decrease in variation within these factors resulted in lower variance between cutting efficiency results. The variance between results was found to be lowest in pine when knots were excluded. The variance in polyethylene was slightly higher but showed promising evidence for being a suitable alternative material for long-term testing.
|
144 |
Measurement and Modeling of Fire Behavior in Leaves and Sparse ShrubsPrince, Dallan R 01 July 2014 (has links) (PDF)
Wildland fuels and fire behavior have been the focus of numerous studies and models which provide operational support to firefighters. However, fuel and fire complexity in live shrubs has resulted in unexpected and sometimes aggressive fire behavior. The combustion of live fuels was studied and modeled, and the results were assimilated into a shrub-scale fire behavior model which assumes fire spread by flame-fuel overlap. Fire spread models have usually assumed that radiation heat transfer is responsible for driving fire spread, but that assumption is a topic of continuing debate, and appears to contradict some experimental observations. A convection-based shrub-scale fire spread model has been developed, building on a heritage of experiments and modeling previously performed at Brigham Young University. This project has (1) characterized fundamental aspects of fire behavior, (2) integrated the resulting submodels of fire behavior into an existing shrub model framework, and (3) produced shrub-scale fire spread experiments and (4) made model comparisons. This research models fire spread as a convection-driven phenomenon and demonstrates strategies for overcoming some of the challenges associated with this novel approach.
|
145 |
Starch Resin Moisture Level Effect on Injection Molding Processability and Molded Part Mechanical Properties with Pure Starch Resin and Polymer BlendsEllingson, Jordan M. 16 March 2013 (has links) (PDF)
The current and forecasted global consumption of plastic packaging and products through the 21st century combined with the already reported and growing negative impact of plastics on the environment due to plastics being synthesized from nonrenewable resources that do not biodegrade is of serious concern. However, recent advances in starch technology including the development of thermoplastic starch (TPS) materials —polymers that are both renewable and biodegradable—have brought hope to reducing this impact. The mechanical properties of thermoplastic starch have often been improved by blending with synthetic polymers. One issue that arises with blending is volatilization of the melt from moisture in the TPS materials. Ecostarch™ a proprietary, pelletized thermoplastic starch resin formulated from potato starch, was processed and tested to observe injection molding processability at various moisture levels, in pure TPS as well as various blend ratios with high-density polyethylene (HDPE) and polypropylene (PP). This study evaluated and analyzed the effects of the TPS pellet moisture content on void formation in the plastic pre-injection melt and subsequent molded part mechanical properties. Statistical analysis of the test results showed that moisture had a significant effect on void formation in the plastic melt. In TPS/HDPE blends, voids percent (as measured by cross section area) increased by 300-350% from 0.6% to 1.4% moisture levels. In unblended TPS, void percent increased by 150% from 0.4% to 1.4% moisture levels. In the unblended TPS parts, impact strength (energy in ft-lb) was decreased by 1% from 0.6% to 1.4% moisture level. In the TPS/HDPE and TPS/PP blends, there was no significant effect on impact strength due to the moisture percent levels of the TPS. Modulus decreased by 25% from 0.4% to 1.4% moisture level in unblended TPS parts. From 0.6% to 1.4% change in TPS moisture content, the modulus of the TPS/HDPE blend decreased by 9% at a 30% TPS/70% HDPE blend and decreased by 14% at a 70% TPS/30% HDPE blend. Though the moisture of TPS did not have a significant impact on the tensile strength of TPS/HDPE blends, the tensile strength of TPS/PP blend samples were significantly affected: a change from 0.6% to 1.4% moisture increased tensile strength 34% at a 70% TPS/30% PP blend and increased tensile strength by 22% at a 30% TPS/70% PP blend. Thus the results of this study highlight the relationships between moisture, voids, and mechanical performance of TPS and TPS/Polymer blends.
|
146 |
Soil Moisture Sensing in Mining Waste Rock: Comparing Calibration Curves of Multiple Low-Cost Capacitance Sensors and a Single TDR Sensor / Mätning av vatteninnehåll i gruvavfall: En jämförelse av kalibreringskurvor för flera billiga kapacitanssensorer och en enda TDR-sensorJørgensen, Rasmus January 2022 (has links)
Measuring soil moisture content (SMC) in mining waste rock is important for assessing and modelling hydrological processes which influence pollutant release. Here, an experimental setup containing mining waste rock is established to compare the performance of 4 Arduino capacitance moisture sensors to one single Time Domain Reflectometry (TDR) sensor. Furthermore, the performance of these sensors is evaluated in both sieved and unsieved mining waste rock. Fitted calibration curves are provided for both the TDR- and Arduino-sensors individually and in combination. These calibration curves are evaluated using the RMSE and R 2 of each curve and compared between sensors and soil texture. It is concluded that using more capacitance sensors significantly improves the fit statistics of the calibration curves and that using at least 4 capacitance sensors can enhance calibration curve fitting. For both the TDR and capacitance sensors, the calibration curves in sieved soil provided the best fit, meaning that soil specific calibration of sensors is recommended. On a sensor individual basis, the temporal precision of the TDR sensor was superior to each individual capacitance sensor. Use of 4 or more Arduino capacitance sensors may especially be justified in circumstances where the spatial variability of SMC is addressed by executing a large number of measurements. Here, the feasibility of the Arduino sensor system means that the use of these low-cost sensors, despite their reduced temporal precision, can be upscaled at relatively small costs.
|
147 |
Lagerung von Pappelrundholz aus Kurzumtriebsplantagen – Evaluierung verschiedener Lagerungsverfahren unter besonderer Berücksichtigung der Holzfeuchte als möglicher Parameter einer automatisierten QualitätsüberwachungStarke, Nicole 25 January 2023 (has links)
Vor dem Hintergrund einer angestrebten stofflichen Nutzung von Pappelholz aus Kurzumtriebsplantagen (KUP) zur Herstellung von Holzwerkstoffen und des eingeschränkten Erntezeitpunktes der Pappeln in den Wintermonaten ergab sich die Frage, wie das Holz über einen Lagerungszeitraum von bis zu neun Monaten bei gleichzeitiger Erhaltung der Holzqualität gelagert werden kann.
Zu diesem Zweck wurden verschiedene Lagerungsverfahren getestet: Trockenlagerung mit und ohne Rinde, Beregnung mit und ohne Rinde, Folienlagerung mit und ohne Rinde sowie einem aus Beregnung und Trockenlagerung kombinierten Verfahren. Insgesamt wurden 105 Raummeter Pappelrundholz aus KUP in zwei verschiedenen Lagerungsperioden 2018 und 2019 eingelagert.
Die Holzqualität des gelagerten Pappelholzes wurde anhand von Untersuchungen zur Veränderung der Darrdichte, der chemischen Zusammensetzung (Cellulose-, Hemicellulosen-, Lignin-, Extraktstoffanteil) und ergänzend durch mikroskopische Untersuchungen bewertet. Ein weiterer Fokus lag auf der Holzfeuchte zur Abschätzung der Gefahr eines Pilzbefalls.
Die Ergebnisse zeigten, dass es bei der Trockenlagerung mit Rinde in der Lagerungsperiode 2019 durch einen festgestellten Befall durch holzzerstörende Pilze, einer Reduktion der Darrdichte von 11 % sowie starken Änderungen der chemischen Zusammensetzung (vor allem Reduktion der Holzpolyosen) zu den stärksten Veränderungen kam. Bei der Trockenlagerung ohne Rinde waren die beobachteten Veränderungen deutlich geringer (maximale Abnahme der Darrdichte 3 %). Bei den beiden Lagerungsverfahren Beregnung und Folienlagerung konnte eine Lagerung des Holzes in einem für holzzerstörende Pilze unkritischen Holzfeuchtebereich nachgewiesen werden. Ein Befall durch holzzerstörende Pilze wurde durch die mikroskopischen Untersuchungen nicht festgestellt. Bei der Beregnung fiel die Veränderung der Darrdichte bei einigen Varianten stärker aus als erwartet. Für eine abschließende Bewertung sind weitere Untersuchungen notwendig. Der Klon Max 1 zeigte oft stärkere Veränderungen als der Klon AF2. Auch hier sind weitere Untersuchungen notwendig.
Aus den Ergebnissen wurde geschlussfolgert, dass die Holzqualität mittels Folienlagerung am besten erhalten werden konnte. Auch die Trockenlagerung ohne Rinde wird aufgrund der geringen festgestellten Veränderungen und im Hinblick auf die geringen Kosten als geeignet erachtet. Es muss jedoch beachtet werden, dass dieses Lagerungsverfahren stark witterungsabhängig ist.:Kurzfassung
Abstract
Abbildungsverzeichnis
Tabellenverzeichnis
Abkürzungsverzeichnis
1 Einleitung
1.1 Hintergrund
1.2 Ziele und Thesen
1.3 Aufgabenstellung
2 Stand von Wissenschaft und Technik
2.1 Die Pappel und ihr Holz
2.1.1 Die Baumart Pappel
2.1.2 Die Holzart Pappel
2.1.3 Verwendung von Pappelholz
2.2 Kurzumtriebsplantagen (KUP)
2.2.1 Allgemein
2.2.2 Pappel auf Kurzumtriebsplantagen
2.2.3 Verwendung von Pappelholz aus KUP
2.3 Rundholzlagerung
2.3.1 Anwendungsgebiete und Ziele der Rundholzlagerung
2.3.2 Einflussfaktoren auf den Lagerungserfolg
2.3.3 Verfahren der Rundholzlagerung
2.3.3.1 Übersicht über die Lagerungsverfahren
2.3.3.2 Trockenlagerung
2.3.3.3 Nasslagerung
2.3.3.4 Folienlagerung
2.3.4 Risiken für die Rundholzlagerung
2.3.4.1 Einleitung
2.3.4.2 Biotische Risiken
2.3.4.3 Abiotische Risiken
2.3.5 Lagerung von Pappelrundholz aus Kurzumtriebsplantagen
2.4 Holzfeuchtebestimmung und Holzfeuchtemonitoring durch elektrische Widerstands-messung
2.4.1 Überblick Verfahren zur Bestimmung der Holzfeuchte
2.4.2 Elektrische Widerstandsmessung
2.4.2.1 Prinzip
2.4.2.2 Kalibrierfunktionen
2.4.3 Monitoring durch elektrische Widerstandsmessung
3 Material und Methoden
3.1 Material
3.1.1 Eingesetztes Versuchsmaterial für die Lagerungsperiode 2018
3.1.2 Eingesetztes Versuchsmaterial für die Lagerungsperiode 2019
3.2 Methoden
3.2.1 Überblick Methoden
3.2.2 Versuchsaufbau
3.2.2.1 Lagerungsperiode 2018
3.2.2.2 Lagerungsperiode 2019
3.2.3 Untersuchungen
3.2.3.1 Überblick Untersuchungen und Beprobungsstrategie
3.2.3.2 Holzfeuchte
3.2.3.3 Darrdichte
3.2.3.4 Chemische Analysen
3.2.3.5 Pilz- und Bakterienbefall
3.2.3.6 Triebbildung
3.2.3.7 Gasanalyse
3.2.3.8 Elektrische Widerstandsmessung zur Ermittlung der Holzfeuchte
3.2.4 Dokumentation von Witterungsdaten
3.2.5 Statistische Auswertung
4 Ergebnisse
4.1 Systematik der Ergebnisdarstellung
4.2 Witterungsdaten
4.2.1 Lagerungsperiode 2018
4.2.2 Lagerungsperiode 2019
4.3 Gasatmosphäre
4.4 Holzfeuchte
4.4.1 Lagerungsperiode 2018
4.4.2 Lagerungsperiode 2019
4.5 Darrdichte
4.5.1 Lagerungsperiode 2018
4.5.2 Lagerungsperiode 2019
4.6 Chemische Zusammensetzung
4.6.1 Lagerungsperiode 2018
4.6.2 Lagerungsperiode 2019
4.7 Pilz- und Bakterienbefall
4.7.1 Lagerungsperiode 2018
4.7.2 Lagerungsperiode 2019
4.8 Triebbildung
4.8.1 Lagerungsperiode 2018
4.8.2 Lagerungsperiode 2019
4.9 Sonstige Beobachtungen
4.9.1 Rissbildungen bei der Trockenlagerung
4.9.2 Mäuse und einwachsende Pflanzenteile
4.10 Monitoring der Holzfeuchteentwicklung im Laufe der Lagerungsperiode 2019
4.10.1 Erstellung der Kalibrierfunktion für Pappelholz
4.10.1.1 Modell 1
4.10.1.2 Modell 2
4.10.2 Anwendung der ermittelten Kalibrierfunktion auf die mittels Datenlogger aufgezeichneten Messwerte im Zuge der Lagerungsperiode 2019
5 Diskussion
5.1 Evaluierung der Lagerungsverfahren unter Berücksichtigung der Holzfeuchte
5.1.1 Erwartete Holzqualität der einzelnen Lagerungsvarianten aufgrund der festgestellten Holzfeuchte
5.1.2 Trockenlagerung
5.1.2.1 Holzfeuchte und Witterungsbedingungen
5.1.2.2 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilzbefall
5.1.2.3 Zusammenfassende Einschätzung zur Trockenlagerung
5.1.3 Beregnung
5.1.3.1 Holzfeuchte
5.1.3.2 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilz- und Bakterienbefall
5.1.3.3 Zusammenfassende Einschätzung zur Beregnung
5.1.4 Kombiniertes Verfahren aus Beregnung und Trockenlagerung
5.1.4.1 Holzfeuchte und Witterungsbedingungen
5.1.4.2 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilz- und Bakterienbefall
5.1.4.3 Zusammenfassende Einschätzung zum kombinierten Verfahren
5.1.5 Folienlagerung
5.1.5.1 Gasanalyse in den Folienpaketen
5.1.5.2 Holzfeuchte
5.1.5.3 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilz- und Bakterienbefall
5.1.5.4 Zusammenfassende Einschätzung zur Folienlagerung
5.1.6 Vergleich der Klone Max 1 und AF2
5.1.7 Zusammenfassung und Bewertung der Lagerungsvarianten
5.2 Monitoring der Holzfeuchteentwicklung im Laufe der Lagerungsperiode durch elektrische Widerstandsmessung
5.2.1.1 Kalibierfunktion für Pappelholz aus KUP
5.2.1.2 Einsatzmöglichkeit der elektrischen Widerstandsmessung zur Qualitätsüberwachung von Pappelrundholzpoltern
6 Schlussfolgerung
7 Zusammenfassung
8 Ausblick
Literaturverzeichnis / Considering the desired material use of poplar wood from short-rotation coppices (SRC) for the production of wooden materials and the limited harvest season, the question arose how the wood should be stored over a period of up to nine months while preserving the wood quality (at the same time).
For this purpose, different storage methods were tested: storage in compact piles with and without bark, storage with water sprinkling with and without bark and storage under oxygen exclusion with and without bark, as well as storage in compact pile with temporary water sprinkling as a combined storage method. A total amount of 105 cubic meters test piles with poplar logs from SRC were set up in two different storage periods, 2018 and 2019. The clones Max 1 and AF2 were evaluated using 18 different storage variants.
The quality of the stored poplar wood was evaluated based on changes in the wood density ρ0, chemical composition (cellulose, hemicelluloses, lignin and extract content) complemented by microscopic examinations. A further focus was the wood moisture content evaluation to estimate the potential risk of fungal decay.
The results demonstrated that storage in compact piles in the storage period of 2019 resulted in the biggest changes caused by an infestation of wood-destroying fungi, 11.1% reduction of the wood density ρ0, and significant changes of chemical composition, in particular reduction of wood polyoses. Storage in compact piles without bark showed substantially lower changes (maximum decrease of wood density ρ0 of 3.3%). For storage with water sprinkling and storage under oxygen exclusion it could be shown that both result in storage conditions with an uncritical wood moisture range in relation to wood-destroying fungi (fungi decay). Fungi decay could not be observed by microscopic examination. Additional studies are required for a final assessment. Clone Max 1 showed frequently stronger changes than clone AF2. Further investigation is needed here as well.
Based on the results it can be concluded that the wood quality could be preserved best by using the storage under oxygen exclusion. Storage in compact piles without bark can be considered as suitable as well due to the minor changes and considering the low costs. However, it has to be taken into account hat this storage method is very climate-dependent.:Kurzfassung
Abstract
Abbildungsverzeichnis
Tabellenverzeichnis
Abkürzungsverzeichnis
1 Einleitung
1.1 Hintergrund
1.2 Ziele und Thesen
1.3 Aufgabenstellung
2 Stand von Wissenschaft und Technik
2.1 Die Pappel und ihr Holz
2.1.1 Die Baumart Pappel
2.1.2 Die Holzart Pappel
2.1.3 Verwendung von Pappelholz
2.2 Kurzumtriebsplantagen (KUP)
2.2.1 Allgemein
2.2.2 Pappel auf Kurzumtriebsplantagen
2.2.3 Verwendung von Pappelholz aus KUP
2.3 Rundholzlagerung
2.3.1 Anwendungsgebiete und Ziele der Rundholzlagerung
2.3.2 Einflussfaktoren auf den Lagerungserfolg
2.3.3 Verfahren der Rundholzlagerung
2.3.3.1 Übersicht über die Lagerungsverfahren
2.3.3.2 Trockenlagerung
2.3.3.3 Nasslagerung
2.3.3.4 Folienlagerung
2.3.4 Risiken für die Rundholzlagerung
2.3.4.1 Einleitung
2.3.4.2 Biotische Risiken
2.3.4.3 Abiotische Risiken
2.3.5 Lagerung von Pappelrundholz aus Kurzumtriebsplantagen
2.4 Holzfeuchtebestimmung und Holzfeuchtemonitoring durch elektrische Widerstands-messung
2.4.1 Überblick Verfahren zur Bestimmung der Holzfeuchte
2.4.2 Elektrische Widerstandsmessung
2.4.2.1 Prinzip
2.4.2.2 Kalibrierfunktionen
2.4.3 Monitoring durch elektrische Widerstandsmessung
3 Material und Methoden
3.1 Material
3.1.1 Eingesetztes Versuchsmaterial für die Lagerungsperiode 2018
3.1.2 Eingesetztes Versuchsmaterial für die Lagerungsperiode 2019
3.2 Methoden
3.2.1 Überblick Methoden
3.2.2 Versuchsaufbau
3.2.2.1 Lagerungsperiode 2018
3.2.2.2 Lagerungsperiode 2019
3.2.3 Untersuchungen
3.2.3.1 Überblick Untersuchungen und Beprobungsstrategie
3.2.3.2 Holzfeuchte
3.2.3.3 Darrdichte
3.2.3.4 Chemische Analysen
3.2.3.5 Pilz- und Bakterienbefall
3.2.3.6 Triebbildung
3.2.3.7 Gasanalyse
3.2.3.8 Elektrische Widerstandsmessung zur Ermittlung der Holzfeuchte
3.2.4 Dokumentation von Witterungsdaten
3.2.5 Statistische Auswertung
4 Ergebnisse
4.1 Systematik der Ergebnisdarstellung
4.2 Witterungsdaten
4.2.1 Lagerungsperiode 2018
4.2.2 Lagerungsperiode 2019
4.3 Gasatmosphäre
4.4 Holzfeuchte
4.4.1 Lagerungsperiode 2018
4.4.2 Lagerungsperiode 2019
4.5 Darrdichte
4.5.1 Lagerungsperiode 2018
4.5.2 Lagerungsperiode 2019
4.6 Chemische Zusammensetzung
4.6.1 Lagerungsperiode 2018
4.6.2 Lagerungsperiode 2019
4.7 Pilz- und Bakterienbefall
4.7.1 Lagerungsperiode 2018
4.7.2 Lagerungsperiode 2019
4.8 Triebbildung
4.8.1 Lagerungsperiode 2018
4.8.2 Lagerungsperiode 2019
4.9 Sonstige Beobachtungen
4.9.1 Rissbildungen bei der Trockenlagerung
4.9.2 Mäuse und einwachsende Pflanzenteile
4.10 Monitoring der Holzfeuchteentwicklung im Laufe der Lagerungsperiode 2019
4.10.1 Erstellung der Kalibrierfunktion für Pappelholz
4.10.1.1 Modell 1
4.10.1.2 Modell 2
4.10.2 Anwendung der ermittelten Kalibrierfunktion auf die mittels Datenlogger aufgezeichneten Messwerte im Zuge der Lagerungsperiode 2019
5 Diskussion
5.1 Evaluierung der Lagerungsverfahren unter Berücksichtigung der Holzfeuchte
5.1.1 Erwartete Holzqualität der einzelnen Lagerungsvarianten aufgrund der festgestellten Holzfeuchte
5.1.2 Trockenlagerung
5.1.2.1 Holzfeuchte und Witterungsbedingungen
5.1.2.2 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilzbefall
5.1.2.3 Zusammenfassende Einschätzung zur Trockenlagerung
5.1.3 Beregnung
5.1.3.1 Holzfeuchte
5.1.3.2 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilz- und Bakterienbefall
5.1.3.3 Zusammenfassende Einschätzung zur Beregnung
5.1.4 Kombiniertes Verfahren aus Beregnung und Trockenlagerung
5.1.4.1 Holzfeuchte und Witterungsbedingungen
5.1.4.2 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilz- und Bakterienbefall
5.1.4.3 Zusammenfassende Einschätzung zum kombinierten Verfahren
5.1.5 Folienlagerung
5.1.5.1 Gasanalyse in den Folienpaketen
5.1.5.2 Holzfeuchte
5.1.5.3 Veränderung der Darrdichte und der chemischen Zusammensetzung, Pilz- und Bakterienbefall
5.1.5.4 Zusammenfassende Einschätzung zur Folienlagerung
5.1.6 Vergleich der Klone Max 1 und AF2
5.1.7 Zusammenfassung und Bewertung der Lagerungsvarianten
5.2 Monitoring der Holzfeuchteentwicklung im Laufe der Lagerungsperiode durch elektrische Widerstandsmessung
5.2.1.1 Kalibierfunktion für Pappelholz aus KUP
5.2.1.2 Einsatzmöglichkeit der elektrischen Widerstandsmessung zur Qualitätsüberwachung von Pappelrundholzpoltern
6 Schlussfolgerung
7 Zusammenfassung
8 Ausblick
Literaturverzeichnis
|
148 |
Adaptiv styrning avtvärcirkulerande kanaltork : Analys och förutsättningar för adaptivfuktkvotsberäkning och justering av torktid / Adaptive Control of Cross CirculatingContinuous Kiln dryer : Analysis and conditions for adaptive control of crosscirculating continuous dryerBacklund, Gustav January 2023 (has links)
För att minska energiförbrukningen och höja kapaciteten vid virkestorkning kan adaptiv styrning användas. Adaptiv styrning är en typ av processåterkoppling som visar på hur torkningen fortskrider och kan användas för att styra torkprocessen optimalt. Adaptiv styrning har funnits till kammartorkar länge. Tvärcirkulerande kanaltorkar (TC) liknar kammartorkar och man vill nu införa adaptiv styrning på dem. Syftet med studien var att analysera förutsättningarna för att tillämpa adaptiv styrning i TC-torken. En fältstudie genomfördes där funktionen adaptiv fuktkvotsberäkning som används som styrvariabel vid adaptiv styrning kontrollerades. Klimatmätningar under torkning genomfördes för att kontrollera om temperaturgivarna ger en bra bild av klimatet vid torksatsen. Resultatet visar att funktionen adaptiv fuktkvotsberäkning stämmer överens för start- och slutfuktkvot i TC-torken. Funktionen fungerade något sämre på satser som innehöll virke med blandade dimensioner. Klimatmätningarna visar att temperaturgivarna återskapar klimatet vid virkessatsen på ett korrekt vis. Simuleringar visar att virket idag övertorkas och att en viss förkortning av torktiden hade varit möjlig. Det finns goda förutsättningar för att tillämpa adaptiv styrning i TC-torken
|
149 |
Validation of the Enhanced Integrated Climatic Model (EICM) for the Ohio SHRP Test Road at U.S. 23Quintero, Natalia M. January 2007 (has links)
No description available.
|
150 |
Diagnostics of Oil-Impregnated Paper Insulation Systems by Utilizing Lightning and Switching TransientsNikjoo, Roya January 2014 (has links)
Development of the power gridtowards a more reliable and smarter system requires frequent on-line monitoring of the power components. Power transformers and their bushings are particularly important components in a power transmission system and their insulation degradation may lead to catastrophic failures. Time consuming and costly replacement of these components raise the importance of their frequent monitoring. A fault in a power transformer bushing can also involve in the failure of the transformer. Therefore, on-line diagnostics of power transformers and their bushings is of great interest. Several methods exist for diagnostics of these components. However, some of them can only be done off-line in maintenance periods, and the existing on-line methods generally provide less information, especially on the internal solid insulation parts. In this project, a new technique for on-line diagnostics of the power transformer and the bushing insulation is proposed. In this technique, natural transients happening in the power system such as lightning and switching surges can be used as stimuli for on-line dielectric response measurements. This technique can provide information on insulation close to what Dielectric Spectroscopy offers in off-line measurements. The wide-ranging frequency content of power system transients is their advantage for being usedas stimuli when measuring the Dielectric Response. The response can have particular signatures due to different types of defects in the insulation varying with frequency. Oil-impregnated paper as a major insulation component in power transformer and its bushing has been investigated in this project. Moisture content and temperature, as two important degradation factors in this type of insulation, have been studied to evaluate the performance of the proposed technique in the diagnostics of the oil-impregnated paper. The results are verified with the dielectric response obtained through commercial instruments. The results show that the proposed technique has the ability to track the changes in dielectric response due to the moisture content and temperature. Measurements were done at both highvoltage (40kV) and low voltage (10V) levels, and the corresponding circuit models to achieve reasonable accuracy for the results are discussed. Moving on from the material samples, a further study was done on three service-aged 150 kV bushings to investigate the feasibility of the technique on the diagnostics of power transformer bushings. Their dielectric response measured by the transient stimuli showed good agreement with their response obtained by the commercial instruments. The effect of the transformer winding on the transient response of the bushing is a further aspect of the real conditions for on-line diagnostics. This has been investigated through the simulation of transient models for transformers and bushings, and possible solutions for distinguishing the responses are presented. The proposed new on-line diagnostics technique by utilizing natural transients can provide information about the insulation system in a certain range of frequency without interrupting the operation or requiring an external voltage source. However, the validity range of the results depends on the bandwidth of the applied transients and other measurement considerations. This approach can be valuable in frequent monitoring of dielectric properties of the power transformers and their bushings as a complement to the other available on-line techniques. / <p>QC 20140409</p>
|
Page generated in 0.0625 seconds