• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 14
  • 4
  • 1
  • Tagged with
  • 38
  • 38
  • 14
  • 13
  • 10
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Ensaio clínica controlado e randomizado para avaliar a imunogenicidade e reatogenicidade da vacina contra hepatite B (butang(R)) aplicada em recém-nascidos na região glútea ou vasto lateral da cocha / Randomized controlled clinical trial to evaluate the immunogenicity and reactogenicity of the vaccine against hepatitis B (Butang (R)) applied to newborns in the buttock or the vastus lateralis cocha

JUNQUEIRA, Ana Luiza Neto 13 August 2009 (has links)
Made available in DSpace on 2014-07-29T15:25:13Z (GMT). No. of bitstreams: 1 TESE ANA LUIZA NETO JUNQUEIRA 2009.pdf: 346064 bytes, checksum: dd50393164905524036f6c970157aff8 (MD5) Previous issue date: 2009-08-13 / This study is the first randomized controlled clinical trial for assessing the immunogenicity and reatogenicity of the Butang® vaccine in full term newborns, who were given the first vaccine dose within the first 12 hours of life, comparing two regions of application for the vaccine: anterolateral thigh (ALT) and ventrogluteal (VG). Butang® response was assessed in 224 newborns who were given the vaccine in the VG region and 250 in the ALT one. Both groups were similar regarding gender, weight, timing interval between doses of the vaccine and maternal characteristics. When comparing Butang® immunogenicity, we verified that the proportion of babies who developed anti-HBs protecting titres after three vaccine doses in the VG region was of 97.8% (IC 95%: 94.8 99.3) with geometric mean titer (GMT) of 427.5 mUI/mL (IC 95%: 344.9 530.0), similar to those who were given in the ALT region (97.6%; IC 95%: 94.8 99.1; GMT: 572.0 mUI/mL; IC 95%: 471.1 694.6), which provides evidence that this place is appropriate for hepatitis B vaccination. Eleven newborns did not respond to Butang®, being six of them vaccinated in the VG region and five in the ALT. The most of them were male, one factor which seems to interfere with hepatitis B vaccine response. We verified an increasing proportion of local reactions and fever according to the number of doses given. In addition, after the third dose the proportion of induration (4.0 vs. 11.4) was higher among babies who were given the vaccine in the ALT region when compared to those who were given in the VG region (p < 0,05). No association was observed concerning maternal anti-HBs titres and newborn vaccine response. The evidences of this study showed that the VG region is a safe and immunogenic site to hepatitis B vaccine administration in newborns. / Este estudo trata-se do primeiro ensaio clínico randomizado controlado, para avaliação da imunogenicidade e reatogenicidade da vacina Butang® em recém-nascidos a termo, que receberam a primeira dose da vacina nas primeiras doze horas de vida, comparando duas regiões de aplicação do imunógeno: ventro glútea (VG) e vasto lateral da coxa (VLC). A resposta à Butang® foi avaliada em 224 RN vacinados na região VG e 250 na VLC. Os dois grupos foram semelhantes quanto ao sexo, peso, intervalo de tempo entre as doses da vacina e características maternas. Ao comparar a imunogenicidade da Butang®, verificou-se que a proporção de crianças que desenvolveu títulos protetores de anti-HBs após a vacinação na região VG foi de 97,8% (IC 95%: 94,8-99,3) com média geométrica dos títulos (GMT) de anti-HBs de 427,5 mUI/mL (IC 95%: 344,9 530,0), sendo semelhante às vacinadas na região VLC (97,6%; IC 95%: 94,8 99,1; GMT: 572,0 mUI/mL; IC 95%: 471,1 694,6), evidenciando, portanto, esses locais como apropriados para a administração do imunógeno. Onze RN não responderam à Butang® com títulos protetores, sendo que cinco foram vacinados na região VG e seis na VLC. A maioria dessas crianças era do sexo masculino, um fator que parece interferir na resposta vacinal contra hepatite B. Em geral, observou-se uma proporção maior de reações locais e febre de acordo com o número de doses recebidas. Além disso, após a terceira dose da vacina, a proporção de enduração foi menor (4,0 vs. 11,4) em crianças vacinadas na região VG do que nas vacinadas na VLC (p < 0,05). Não foi observada qualquer associação entre títulos de anti-HBs maternos e resposta vacinal dos seus conceptos. As evidências deste estudo mostram que a região VG é um local seguro e imunogênico para a administração da vacina contra hepatite B em lactentes.
22

Influência dos níveis séricos de bilirrubina sobre a ocorrência e a evolução da sepse neonatal em recém-nascidos pré-termo com idade gestacional menor que 36 semanas / Influence of serum bilirubin levels on the occurrence and course of neonatal sepsis in preterm infants younger than 36 gestational age weeks

Claudio Ribeiro Aguiar 04 July 2007 (has links)
INTRODUÇÃO: nos recém-nascidos, diversos componentes das defesas antioxidantes têm se mostrado deficientes. A bilirrubina possui potente ação antioxidante podendo compensar a deficiência dos demais componentes. Essa ação é potencializada pela biliverdina redutase. Esse estudo teve como objetivo identificar o efeito protetor da bilirrubina sobre a sepse neonatal em recém nascidos prematuros. MÉTODOS: estudo de coorte realizado em duas UTI neonatais. Participaram recém-nascidos com idade gestacional inferior a 36 semanas e peso de nascimento entre 750 e 1750 g. As determinações da bilirrubina e da carbonil proteína fizeram-se: a) ao nascimento b) com três dias c) com sete dias e d) com 14 dias de vida. Utilizou-se o teste t de Student nas comparações entre médias. Com as medidas de bilirrubina com três dias foi construída curva ROC. O ponto de inflexão dessa curva separou um grupo exposto a níveis altos de outro (controle) com níveis baixos de bilirrubina. Determinou-se Risco Relativo e intervalo de confiança de 95%. Para variáveis categóricas, utilizou-se o teste do Qui quadrado. A significância estatística foi &#945;=5%. RESULTADOS: o estudo incluiu 53 pacientes. Sepse foi confirmada por hemocultura em 24 pacientes (45,3%). Foram 12 (22,6%) os pacientes com sepse clínica perfazendo 36 (67,9%) pacientes com todas formas de sepse. Sepse grave foi diagnosticada em 21 pacientes (39,6%). Nas comparações entre os valores de bilirrubina nos pacientes que apresentaram cada uma das três formas de sepse e nos pacientes sem sepse houve diferença significante na maioria das situações. Não houve diferença significante nas medidas ao nascimento em todas as formas de sepse e nas medidas aos 14 dias para os pacientes com sepse grave. Ótimos resultados estatísticos ocorreram nas comparações com três dias de vida entre pacientes com sepse comprovada e pacientes sem sepse com p= 0,0009. O ponto de inflexão da curva ROC, com bilirrubina em 9,8mg% separou os pacientes em grupo exposto e não exposto. Comparação quanto à presença ou não de sepse entre os grupos mostrou diferença estatisticamente significante, considerando-se cada uma das formas de sepse analisadas. Para sepse confirmada encontrou-se RR=0,39 (IC95% 0,22- 0,71) e p=0,0008. Nas curvas padrão para bilirrubina, houve diferença significante entre as áreas das duas curvas, com os pacientes sem sepse apresentando área maior. A correlação entre os valores máximos de bilirrubina e os valores máximos da carbonil proteína foi inversa e estatisticamente significante (p=0,016). A diferença entre os valores da carbonil proteína nos pacientes com cada uma das formas de sepse analisadas e os dos pacientes sem sepse, não atingiu significância estatística. O conjunto dos resultados do estudo mostra uma relação estatisticamente significante entre níveis mais elevados de bilirrubina e menor incidência e gravidade da sepse neonatal e uma correlação significante entre bilirrubina e carbonil proteína. CONCLUSÃO: maiores níveis séricos de bilirrubina protegem os prematuros da ocorrência e gravidade da sepse devido as suas propriedades antioxidantes. / INTRODUCTION: several components of the antioxidative defenses are deficient in the newborn. Bilirubin is a potent antioxidant and can counterbalance the deficiency of those components. This antioxidant action is potencialized by biliverdin reductase. The present study aimed at identifying the protective effect of bilirubin on neonatal sepsis in premature babies. METHODS: cohort study, carried out in two neonatal intensive care unities. Newborns younger than 36 gestational age weeks and birth weight between 750 and 1750g were included in the study. Bilirubin and protein carbonyl measurements were performed: a) at birth, b) at day three, c) at day seven, d) at day fourteen. Student t test was used for mean comparisons. Bilirubin measurements at day three were used to build a ROC curve. The inflection point of this curve separated the high bilirubin from the low bilirubin group. Relative risk and 95% confidence interval were determined. Chi-square test was applied for categorical variables and the significance level was set at &#945;=5%. RESULTS: fifty-three patients were included in the study. Twenty-four patients (45.3%) had proven sepsis, twelve (22.6%) had clinical sepsis, totaling 36 (67.9%) patients with all forms of sepsis and 21 (39.6%) patients with severe sepsis. Comparisons between bilirubin values in patients with each form of sepsis and patients without sepsis showed significant differences in most of the situations. There was no statistically significant difference in birth measures in all forms of sepsis as well as in day 14 measurements for severe sepsis. Very good statistical results were found on day three comparisons between proven sepsis and no sepsis patients p=0.0009. The ROC curve inflection point, with bilirubin level at 9.8 mg%, identified an exposed and a non-exposed group. Comparisons regarding the presence of sepsis between groups showed a statistically significant difference, considering each of the analyzed sepsis forms. For proven sepsis RR=0.39 (95%CI 0.22-0.71) p=0.0008. Bilirubin curves showed a significant difference between the areas of the two curves, with patients without sepsis displaying a larger area. The correlation between bilirubin maximum values and protein carbonyl maximum values was inverse and significant (p=0.016). The difference regarding protein carbonyl values between patients with each form of sepsis and patients without sepsis did not reach statistical significance. These results show a statistical significant relation between higher bilirubin levels and a lower incidence and severity of neonatal sepsis and a significant correlation between bilirubin and protein carbonyl. CONCLUSION: higher bilirubin levels protect premature babies from the occurrence and severity of sepsis due to its antioxidative properties.
23

Adaptação transcultural e validação clínica da Neonatal Infant Pain Scale para uso no Brasil

Motta, Giordana de Cássia Pinheiro da January 2013 (has links)
Recém-nascidos enfermos experienciam a dor rotineiramente associada a procedimentos invasivos dentro da Unidade de Terapia Intensiva Neonatal. A avaliação da dor tem como objetivo fornecer dados para determinar ações que aliviem a dor do neonato. A Neonatal Infant Pain Scale é uma escala de avaliação da dor para recém-nascidos validada no Canadá e utilizada no Brasil, porém não há um estudo de adaptação transcultural e validação para o país. Este estudo teve o objetivo de realizar a adaptação transcultural e validação clínica do instrumento Neonatal Infant Pain Scale para uso no Brasil. Utilizou-se os passos propostos por Beaton para adaptação transcultural de instrumentos de medida em saúde, envolvendo as etapas de tradução inicial, síntese entre os tradutores, retrotradução, revisão por comitê de especialistas e testagem da versão pré-final a fim de garantir equivalência entre o instrumento original e a tradução. O instrumento final adaptado foi submetido à validação clínica para avaliação da manutenção das propriedades psicométricas de validade, confiabilidade e consistência interna. A amostra consistiu de 60 recém-nascidos a termo e saudáveis submetidos a um procedimento doloroso que foi filmado e avaliado por seis enfermeiros posteriormente, sendo que cada vídeo foi avaliado por dois enfermeiros (confiabilidade interobservador) e reavaliado por um deles (confiabilidade intraobservador). Para os dados da validação clínica, foram realizados os testes estatísticos t de Student, coeficiente kappa ajustado por PABAK, método de Bland-Altman e coeficiente alfa de Cronbach. O estudo foi realizado na unidade de neonatologia de um hospital universitário de Porto Alegre, RS, entre setembro de 2011 e setembro de 2012. Os princípios éticos foram respeitados e foi consentida permissão do hospital detentor dos direitos sobre a escala e do seu autor para o estudo. Após a tradução e elaboração da versão pré-final, sua clareza foi avaliada por 32 profissionais da saúde através de uma escala likert, resultando em um nível de clareza superior a 87,5%. A versão adaptada para o Brasil, agora chamada Escala de Dor no Recém-Nascido (NIPS - Brasil), demonstrou muito boa confiabilidade inter e intraobservador, com PABAK de 0,93 na concordância em relação ao escore total, sendo que no gráfico de Bland-Altman a concordância inter e intraobservadores ficou acima de 95% e 90%, respectivamente. A consistência interna foi considerada boa, com alfa de Cronbach de 0,762. Considera-se a adaptação transcultural da Neonatal Infant Pain Scale para o português falado no Brasil estabelecida e validada para uso em recém-nascidos a termo do Brasil submetidos a dor aguda. / Newborns in neonatal intensive care units routinely experience pain associated with invasive procedures. Pain assessment should provide data to define actions to alleviate neonatal pain. The Neonatal Infant Pain Scale is a pain assessment instrument for newborns validated in Canada and used in Brazil, although no cross-cultural adaptation and validation study had been previously performed for use in this country. In this study, the Neonatal Infant Pain Scale was adapted cross-culturally and validated clinically for use in Brazil. The steps recommended by Beaton for the cross-cultural adaptation of health measurement instruments were followed, including initial translations, synthesis of translations, back translations, review by an expert committee and testing of the pre-final version to ensure the equivalence between the original instrument and the translated version. The final adapted instrument was submitted to clinical validation to evaluate the retention of psychometric properties, validity, reliability and internal consistency. The study included 60 healthy term newborns that underwent painful procedures, which were video recorded and later evaluated by six nurses. Each recording was evaluated by two nurses (inter-rater reliability) and re-evaluated by one of them (intra-rater reliability). Clinical validation data were analyzed using the Student t test, the prevalence-adjusted bias-adjusted kappa (PABAK) coefficient, Bland-Altman plots and the Cronbach’s alpha coefficient. The study was conducted in the neonatology unit of a university hospital in Porto Alegre, Brazil, from September 2011 to September 2012. Ethical principles were followed, and the permission to use the scale was granted by its coauthor and the hospital that holds its rights. After translation and preparation of the pre-final version, 32 healthcare workers used a Likert-like scale to assess clarity, which was greater than 87.5%. The version adapted for use in Brazil, now called Escala de Dor no Recém-Nascido (NIPS Brazil) had good inter- and intra-rater reliability, PABAK was 0.93 for the agreement with total score, and inter- and intra-rater agreements were greater than 95% and 90% according to the Bland-Altman plots. Internal consistency was good, with a Cronbach’s alpha of 0.762. This study adapted the Neonatal Infant Pain Scale cross-culturally to Brazilian Portuguese and clinically validated it for use with Brazilian term newborns that experience acute pain. / Recién nacidos enfermos experimentan el dolor rutineramente asociado a procedimientos invasivos dentro de la Unidad de Terapia Intensiva Neonatal. La evaluación del dolor tiene como objetivo proveer datos para determinar acciones que alivien el dolor del neonato. La Neonatal Infant Pain Scale es una escala de evaluación del dolor para recién nacidos validada en Canadá y utilizada en Brasil, pero no hay un estudio de adaptación transcultural y validación para el país. Este estudio tuvo el objetivo de realizar la adaptación transcultural y validación clínica del instrumento Neonatal Infant Pain Scale para uso en Brasil. Se utilizaron los pasos propuestos por Beaton para adaptación transcultural de instrumentos de medida en salud, involucrando las etapas de traducción inicial, síntesis entre los traductores, retrotraducción, revisión por comité de especialistas y testaje de la versión pre-final a fin de garantizar equivalencia entre el instrumento original y la traducción. El instrumento final adaptado fue sometido a la validación clínica para evaluación del mantenimiento de las propiedades psicométricas de validad, confiabilidad y consistencia interna. La muestra consistió de 60 recién nacidos a término y saludables sometidos a un procedimiento doloroso que fue filmado y evaluado por seis enfermeros posteriormente, siendo que cada vídeo fue evaluado por dos enfermeros (confiabilidad interobservador) y reevaluado por uno de ellos (confiabilidad intraobservador). Para los datos de la validación clínica, fueron realizados los testes estadísticos t-student, coeficiente kappa ajustado por PABAK, método de Bland-Altman y coeficiente alfa de Cronbach. El estudio fue realizado en la unidad de neonatología de un hospital universitario de Porto Alegre, RS, entre septiembre de 2011 y septiembre de 2012. Los principios éticos fueron respetados y fue consentido permiso del hospital detentor de los derechos sobre la escala y de su coautor para el estudio. Después de la traducción y elaboración de la versión pre-final, su claridad fue evaluada por 32 profesionales de la salud a través de una escala likert, resultando en un nivel de claridad superior a 87,5%. La versión adaptada para el Brasil, ahora llamada Escala de Dor no Recém-Nascido (Escala de Dolor en el Recién Nacido) (NIPS - Brasil), demostró muy buena confiabilidad inter e intraobservador, con PABAK de 0,93 en la concordancia en relación al escore total, siendo que en el gráfico de Bland- Altman la concordancia inter e intraobservadores quedó arriba de 95% y 90%, respectivamente. La consistencia interna fue considerada buena, con alfa de Cronbach de 0,762. Se considera la adaptación transcultural de la Neonatal Infant Pain Scale para el portugués hablado en Brasil establecida y validada para uso en recién nacidos a término de Brasil sometidos a dolor agudo.
24

Influência dos níveis séricos de bilirrubina sobre a ocorrência e a evolução da sepse neonatal em recém-nascidos pré-termo com idade gestacional menor que 36 semanas / Influence of serum bilirubin levels on the occurrence and course of neonatal sepsis in preterm infants younger than 36 gestational age weeks

Aguiar, Claudio Ribeiro 04 July 2007 (has links)
INTRODUÇÃO: nos recém-nascidos, diversos componentes das defesas antioxidantes têm se mostrado deficientes. A bilirrubina possui potente ação antioxidante podendo compensar a deficiência dos demais componentes. Essa ação é potencializada pela biliverdina redutase. Esse estudo teve como objetivo identificar o efeito protetor da bilirrubina sobre a sepse neonatal em recém nascidos prematuros. MÉTODOS: estudo de coorte realizado em duas UTI neonatais. Participaram recém-nascidos com idade gestacional inferior a 36 semanas e peso de nascimento entre 750 e 1750 g. As determinações da bilirrubina e da carbonil proteína fizeram-se: a) ao nascimento b) com três dias c) com sete dias e d) com 14 dias de vida. Utilizou-se o teste t de Student nas comparações entre médias. Com as medidas de bilirrubina com três dias foi construída curva ROC. O ponto de inflexão dessa curva separou um grupo exposto a níveis altos de outro (controle) com níveis baixos de bilirrubina. Determinou-se Risco Relativo e intervalo de confiança de 95%. Para variáveis categóricas, utilizou-se o teste do Qui quadrado. A significância estatística foi &#945;=5%. RESULTADOS: o estudo incluiu 53 pacientes. Sepse foi confirmada por hemocultura em 24 pacientes (45,3%). Foram 12 (22,6%) os pacientes com sepse clínica perfazendo 36 (67,9%) pacientes com todas formas de sepse. Sepse grave foi diagnosticada em 21 pacientes (39,6%). Nas comparações entre os valores de bilirrubina nos pacientes que apresentaram cada uma das três formas de sepse e nos pacientes sem sepse houve diferença significante na maioria das situações. Não houve diferença significante nas medidas ao nascimento em todas as formas de sepse e nas medidas aos 14 dias para os pacientes com sepse grave. Ótimos resultados estatísticos ocorreram nas comparações com três dias de vida entre pacientes com sepse comprovada e pacientes sem sepse com p= 0,0009. O ponto de inflexão da curva ROC, com bilirrubina em 9,8mg% separou os pacientes em grupo exposto e não exposto. Comparação quanto à presença ou não de sepse entre os grupos mostrou diferença estatisticamente significante, considerando-se cada uma das formas de sepse analisadas. Para sepse confirmada encontrou-se RR=0,39 (IC95% 0,22- 0,71) e p=0,0008. Nas curvas padrão para bilirrubina, houve diferença significante entre as áreas das duas curvas, com os pacientes sem sepse apresentando área maior. A correlação entre os valores máximos de bilirrubina e os valores máximos da carbonil proteína foi inversa e estatisticamente significante (p=0,016). A diferença entre os valores da carbonil proteína nos pacientes com cada uma das formas de sepse analisadas e os dos pacientes sem sepse, não atingiu significância estatística. O conjunto dos resultados do estudo mostra uma relação estatisticamente significante entre níveis mais elevados de bilirrubina e menor incidência e gravidade da sepse neonatal e uma correlação significante entre bilirrubina e carbonil proteína. CONCLUSÃO: maiores níveis séricos de bilirrubina protegem os prematuros da ocorrência e gravidade da sepse devido as suas propriedades antioxidantes. / INTRODUCTION: several components of the antioxidative defenses are deficient in the newborn. Bilirubin is a potent antioxidant and can counterbalance the deficiency of those components. This antioxidant action is potencialized by biliverdin reductase. The present study aimed at identifying the protective effect of bilirubin on neonatal sepsis in premature babies. METHODS: cohort study, carried out in two neonatal intensive care unities. Newborns younger than 36 gestational age weeks and birth weight between 750 and 1750g were included in the study. Bilirubin and protein carbonyl measurements were performed: a) at birth, b) at day three, c) at day seven, d) at day fourteen. Student t test was used for mean comparisons. Bilirubin measurements at day three were used to build a ROC curve. The inflection point of this curve separated the high bilirubin from the low bilirubin group. Relative risk and 95% confidence interval were determined. Chi-square test was applied for categorical variables and the significance level was set at &#945;=5%. RESULTS: fifty-three patients were included in the study. Twenty-four patients (45.3%) had proven sepsis, twelve (22.6%) had clinical sepsis, totaling 36 (67.9%) patients with all forms of sepsis and 21 (39.6%) patients with severe sepsis. Comparisons between bilirubin values in patients with each form of sepsis and patients without sepsis showed significant differences in most of the situations. There was no statistically significant difference in birth measures in all forms of sepsis as well as in day 14 measurements for severe sepsis. Very good statistical results were found on day three comparisons between proven sepsis and no sepsis patients p=0.0009. The ROC curve inflection point, with bilirubin level at 9.8 mg%, identified an exposed and a non-exposed group. Comparisons regarding the presence of sepsis between groups showed a statistically significant difference, considering each of the analyzed sepsis forms. For proven sepsis RR=0.39 (95%CI 0.22-0.71) p=0.0008. Bilirubin curves showed a significant difference between the areas of the two curves, with patients without sepsis displaying a larger area. The correlation between bilirubin maximum values and protein carbonyl maximum values was inverse and significant (p=0.016). The difference regarding protein carbonyl values between patients with each form of sepsis and patients without sepsis did not reach statistical significance. These results show a statistical significant relation between higher bilirubin levels and a lower incidence and severity of neonatal sepsis and a significant correlation between bilirubin and protein carbonyl. CONCLUSION: higher bilirubin levels protect premature babies from the occurrence and severity of sepsis due to its antioxidative properties.
25

Being Born Large for Gestational Age : Metabolic and Epidemiological Studies

Ahlsson, Fredrik January 2008 (has links)
Obesity is a major health problem in the Western world. Mean birth weight has increased during the last 25 years. One explanation is that the proportion of large for gestational age (LGA) infants has increased. Such infants risk developing obesity, cardiovascular disease and diabetes later in life. Despite the risk of neonatal hypoglycemia, their postnatal metabolic adaptation has not been investigated. Our data, obtained with stable isotope labeled compounds, demonstrate that newborn LGA infants have increased lipolysis and decreased insulin sensitivity. After administration of glucagon, the plasma levels of glucose and the rate of glucose production increased. The simultaneous increase in insulin correlated with the decrease in lipolysis, indicating an antilipolytic effect of insulin in these infants. We also demonstrated an intergenerational effect of being born LGA, since women born LGA, were at higher risk of giving birth to LGA infants than women not born LGA. Further, the LGA infants formed three subgroups: born long only, born heavy only, and born both long and heavy. Infants born LGA of women with high birth weight or adult obesity were at higher risk of being LGA concerning weight alone, predisposing to overweight and obesity at childbearing age. In addition we found that pregnant women with gestational diabetes were at increased risk of giving birth to infants that were heavy alone. This could explain the risk of both perinatal complications and later metabolic disease in infants of this group of women. To identify determinants of fetal growth, 20 pregnant women with a wide range of fetal weights were investigated at 36 weeks of gestation. Maternal fat mass was strongly associated with insulin resistance. Insulin resistance was related to glucose production, which correlated positively with fetal size. The variation in resting energy expenditure, which was closely related to fetal weight, was largely explained by BMI, insulin resistance, and glucose production. Lipolysis was not rate limiting for fetal growth in this group of women. Consequently, high maternal glucose production due to a high fat mass may result in excessive fetal growth.
26

Adaptação transcultural e validação clínica da Neonatal Infant Pain Scale para uso no Brasil

Motta, Giordana de Cássia Pinheiro da January 2013 (has links)
Recém-nascidos enfermos experienciam a dor rotineiramente associada a procedimentos invasivos dentro da Unidade de Terapia Intensiva Neonatal. A avaliação da dor tem como objetivo fornecer dados para determinar ações que aliviem a dor do neonato. A Neonatal Infant Pain Scale é uma escala de avaliação da dor para recém-nascidos validada no Canadá e utilizada no Brasil, porém não há um estudo de adaptação transcultural e validação para o país. Este estudo teve o objetivo de realizar a adaptação transcultural e validação clínica do instrumento Neonatal Infant Pain Scale para uso no Brasil. Utilizou-se os passos propostos por Beaton para adaptação transcultural de instrumentos de medida em saúde, envolvendo as etapas de tradução inicial, síntese entre os tradutores, retrotradução, revisão por comitê de especialistas e testagem da versão pré-final a fim de garantir equivalência entre o instrumento original e a tradução. O instrumento final adaptado foi submetido à validação clínica para avaliação da manutenção das propriedades psicométricas de validade, confiabilidade e consistência interna. A amostra consistiu de 60 recém-nascidos a termo e saudáveis submetidos a um procedimento doloroso que foi filmado e avaliado por seis enfermeiros posteriormente, sendo que cada vídeo foi avaliado por dois enfermeiros (confiabilidade interobservador) e reavaliado por um deles (confiabilidade intraobservador). Para os dados da validação clínica, foram realizados os testes estatísticos t de Student, coeficiente kappa ajustado por PABAK, método de Bland-Altman e coeficiente alfa de Cronbach. O estudo foi realizado na unidade de neonatologia de um hospital universitário de Porto Alegre, RS, entre setembro de 2011 e setembro de 2012. Os princípios éticos foram respeitados e foi consentida permissão do hospital detentor dos direitos sobre a escala e do seu autor para o estudo. Após a tradução e elaboração da versão pré-final, sua clareza foi avaliada por 32 profissionais da saúde através de uma escala likert, resultando em um nível de clareza superior a 87,5%. A versão adaptada para o Brasil, agora chamada Escala de Dor no Recém-Nascido (NIPS - Brasil), demonstrou muito boa confiabilidade inter e intraobservador, com PABAK de 0,93 na concordância em relação ao escore total, sendo que no gráfico de Bland-Altman a concordância inter e intraobservadores ficou acima de 95% e 90%, respectivamente. A consistência interna foi considerada boa, com alfa de Cronbach de 0,762. Considera-se a adaptação transcultural da Neonatal Infant Pain Scale para o português falado no Brasil estabelecida e validada para uso em recém-nascidos a termo do Brasil submetidos a dor aguda. / Newborns in neonatal intensive care units routinely experience pain associated with invasive procedures. Pain assessment should provide data to define actions to alleviate neonatal pain. The Neonatal Infant Pain Scale is a pain assessment instrument for newborns validated in Canada and used in Brazil, although no cross-cultural adaptation and validation study had been previously performed for use in this country. In this study, the Neonatal Infant Pain Scale was adapted cross-culturally and validated clinically for use in Brazil. The steps recommended by Beaton for the cross-cultural adaptation of health measurement instruments were followed, including initial translations, synthesis of translations, back translations, review by an expert committee and testing of the pre-final version to ensure the equivalence between the original instrument and the translated version. The final adapted instrument was submitted to clinical validation to evaluate the retention of psychometric properties, validity, reliability and internal consistency. The study included 60 healthy term newborns that underwent painful procedures, which were video recorded and later evaluated by six nurses. Each recording was evaluated by two nurses (inter-rater reliability) and re-evaluated by one of them (intra-rater reliability). Clinical validation data were analyzed using the Student t test, the prevalence-adjusted bias-adjusted kappa (PABAK) coefficient, Bland-Altman plots and the Cronbach’s alpha coefficient. The study was conducted in the neonatology unit of a university hospital in Porto Alegre, Brazil, from September 2011 to September 2012. Ethical principles were followed, and the permission to use the scale was granted by its coauthor and the hospital that holds its rights. After translation and preparation of the pre-final version, 32 healthcare workers used a Likert-like scale to assess clarity, which was greater than 87.5%. The version adapted for use in Brazil, now called Escala de Dor no Recém-Nascido (NIPS Brazil) had good inter- and intra-rater reliability, PABAK was 0.93 for the agreement with total score, and inter- and intra-rater agreements were greater than 95% and 90% according to the Bland-Altman plots. Internal consistency was good, with a Cronbach’s alpha of 0.762. This study adapted the Neonatal Infant Pain Scale cross-culturally to Brazilian Portuguese and clinically validated it for use with Brazilian term newborns that experience acute pain. / Recién nacidos enfermos experimentan el dolor rutineramente asociado a procedimientos invasivos dentro de la Unidad de Terapia Intensiva Neonatal. La evaluación del dolor tiene como objetivo proveer datos para determinar acciones que alivien el dolor del neonato. La Neonatal Infant Pain Scale es una escala de evaluación del dolor para recién nacidos validada en Canadá y utilizada en Brasil, pero no hay un estudio de adaptación transcultural y validación para el país. Este estudio tuvo el objetivo de realizar la adaptación transcultural y validación clínica del instrumento Neonatal Infant Pain Scale para uso en Brasil. Se utilizaron los pasos propuestos por Beaton para adaptación transcultural de instrumentos de medida en salud, involucrando las etapas de traducción inicial, síntesis entre los traductores, retrotraducción, revisión por comité de especialistas y testaje de la versión pre-final a fin de garantizar equivalencia entre el instrumento original y la traducción. El instrumento final adaptado fue sometido a la validación clínica para evaluación del mantenimiento de las propiedades psicométricas de validad, confiabilidad y consistencia interna. La muestra consistió de 60 recién nacidos a término y saludables sometidos a un procedimiento doloroso que fue filmado y evaluado por seis enfermeros posteriormente, siendo que cada vídeo fue evaluado por dos enfermeros (confiabilidad interobservador) y reevaluado por uno de ellos (confiabilidad intraobservador). Para los datos de la validación clínica, fueron realizados los testes estadísticos t-student, coeficiente kappa ajustado por PABAK, método de Bland-Altman y coeficiente alfa de Cronbach. El estudio fue realizado en la unidad de neonatología de un hospital universitario de Porto Alegre, RS, entre septiembre de 2011 y septiembre de 2012. Los principios éticos fueron respetados y fue consentido permiso del hospital detentor de los derechos sobre la escala y de su coautor para el estudio. Después de la traducción y elaboración de la versión pre-final, su claridad fue evaluada por 32 profesionales de la salud a través de una escala likert, resultando en un nivel de claridad superior a 87,5%. La versión adaptada para el Brasil, ahora llamada Escala de Dor no Recém-Nascido (Escala de Dolor en el Recién Nacido) (NIPS - Brasil), demostró muy buena confiabilidad inter e intraobservador, con PABAK de 0,93 en la concordancia en relación al escore total, siendo que en el gráfico de Bland- Altman la concordancia inter e intraobservadores quedó arriba de 95% y 90%, respectivamente. La consistencia interna fue considerada buena, con alfa de Cronbach de 0,762. Se considera la adaptación transcultural de la Neonatal Infant Pain Scale para el portugués hablado en Brasil establecida y validada para uso en recién nacidos a término de Brasil sometidos a dolor agudo.
27

Role komunitní sestry v péči o novorozence, kojence a matky

SCHÖNBAUEROVÁ, Andrea January 2018 (has links)
The main purpose of the research was to explore the role of the community nurse in the care of newborns, infants and their mother and how this kind of care could be included in the current system of preventive care for newborns and infants in the Czech Republic. The research was developed by qualitative and quantitative design. In the first stage of the research, interviews with nurses from the PLDD outpatient department and mothers of infants in the South Bohemian and Pilsen Regions were conducted. Non-standardized questionnaires for nurses and mothers were created from the obtained data. The statistical processing was carried out with MS Excel, where absolute and relative frequencies were calculated and the relationships among the variables at the significance level ? = 0.05 were tested by the use of the chi-squared test and the Pearson correlation coefficient was used. For the needs of the qualitative survey, a research group of six mothers of infants and seven nurses from the PLDD outpatient departments in the South Bohemian and Pilsen Regions was chosen by deliberate selection. For the quantitative survey, a research group of 254 mothers of babies aged 12-24 months was chosen by deliberate selection. The research group of nurses was chosen by deliberate selection and consisted of 196 nurses working in PLDD outpatient departments for more than one year. Multiparas have provably more information at leaving the maternity hospital about breastfeeding techniques, breast milk pumping, nappy changing, hygienic care and bathing, dressing, sleeping, umbilical cord care, and safe handling of the baby. Information about the prevention of sudden infant deaths or the storage of breast milk is at the same level for primiparas as for multiparas. It was found out that there is a statistically significant relationship between the level of awareness and the occurrence of problems in the first year of the child's life. The personal experience of nurses with the visiting service has an influence on whether they attach importance to this service. The current model of preventive care of newborns and babies needs to be critically analysed and appropriately complemented by interventions of the visiting service.
28

Specifika ošetřovatelské péče se zaměřením na potřeby a vývojovou péči novorozenců s extrémně nízkou porodní hmotností / Specifics of nursing care, focusing on the needs and developmental care for infants with extremely low birth weight

TOMKOVÁ, Věra January 2018 (has links)
Neonatology is a branch of medicine which consists of the medical care not only of healthy newborn infants, but also of the ill or premature ones. The number of the premature born infants increases constantly worldwide. It might be caused by women postponing their pregnancies, and very likely also by the growing number of pregnancies achieved by the assisted reproductive technologies. Thanks to improvements in perinatal care of risk pregnancies, guiding preterm labour, and development of neonatal intensive care, it has become possible to save more infants born at the very margin of viability with an extremely low birth weight. The diagnostic, therapeutic and nursing techniques have been developing steadily. It's the methods providing maximum comfort for the child and ensuring the quality of their later life that have been put into forefront. They are a set of measures, which do not disturb the child's reflex behaviour; they support its physiological stability, and thus foster growth and development of the immature organism. The aim of this diploma work is to map the specific needs of the newborn infants with an extremely low birth weight, to find out how these needs are satisfied during the first days after birth, and to determine, how the nursing care supporting the development of the infants takes place in the real life. The theoretical part of the diploma work is based on the scientific papers and resources. The empirical part is based on an observation method, which was carried out at the Neonatal Intensive Care Unit of the University Hospital in Pilsen. The survey proved that the infants' needs are not only on the biological level, but also on the emotional level, and they need appropriate sensomotoric stimulation. The outcomes of the observation show that the greatest problem of the newborn infants with an extremely low birth weight is to satisfy the biological needs i.e. breathing, feeding and defecation. The need of safety and stimulation was satisfied only partly. Based on the information collected by observing the nursing staff, it was possible to lay out areas with a potential to improve the individualized care of the newborns with an extremely low birth weight. These are, above all, the increased level of noise at the unit and thus the sense of sleep and wakefulness of the infants. Furthermore, it's the stimulation of the children and the communication with the parents. The outcomes of the empirical part of this diploma work will be presented at the seminar of the perinatal centre.
29

Adaptação transcultural e validação clínica da Neonatal Infant Pain Scale para uso no Brasil

Motta, Giordana de Cássia Pinheiro da January 2013 (has links)
Recém-nascidos enfermos experienciam a dor rotineiramente associada a procedimentos invasivos dentro da Unidade de Terapia Intensiva Neonatal. A avaliação da dor tem como objetivo fornecer dados para determinar ações que aliviem a dor do neonato. A Neonatal Infant Pain Scale é uma escala de avaliação da dor para recém-nascidos validada no Canadá e utilizada no Brasil, porém não há um estudo de adaptação transcultural e validação para o país. Este estudo teve o objetivo de realizar a adaptação transcultural e validação clínica do instrumento Neonatal Infant Pain Scale para uso no Brasil. Utilizou-se os passos propostos por Beaton para adaptação transcultural de instrumentos de medida em saúde, envolvendo as etapas de tradução inicial, síntese entre os tradutores, retrotradução, revisão por comitê de especialistas e testagem da versão pré-final a fim de garantir equivalência entre o instrumento original e a tradução. O instrumento final adaptado foi submetido à validação clínica para avaliação da manutenção das propriedades psicométricas de validade, confiabilidade e consistência interna. A amostra consistiu de 60 recém-nascidos a termo e saudáveis submetidos a um procedimento doloroso que foi filmado e avaliado por seis enfermeiros posteriormente, sendo que cada vídeo foi avaliado por dois enfermeiros (confiabilidade interobservador) e reavaliado por um deles (confiabilidade intraobservador). Para os dados da validação clínica, foram realizados os testes estatísticos t de Student, coeficiente kappa ajustado por PABAK, método de Bland-Altman e coeficiente alfa de Cronbach. O estudo foi realizado na unidade de neonatologia de um hospital universitário de Porto Alegre, RS, entre setembro de 2011 e setembro de 2012. Os princípios éticos foram respeitados e foi consentida permissão do hospital detentor dos direitos sobre a escala e do seu autor para o estudo. Após a tradução e elaboração da versão pré-final, sua clareza foi avaliada por 32 profissionais da saúde através de uma escala likert, resultando em um nível de clareza superior a 87,5%. A versão adaptada para o Brasil, agora chamada Escala de Dor no Recém-Nascido (NIPS - Brasil), demonstrou muito boa confiabilidade inter e intraobservador, com PABAK de 0,93 na concordância em relação ao escore total, sendo que no gráfico de Bland-Altman a concordância inter e intraobservadores ficou acima de 95% e 90%, respectivamente. A consistência interna foi considerada boa, com alfa de Cronbach de 0,762. Considera-se a adaptação transcultural da Neonatal Infant Pain Scale para o português falado no Brasil estabelecida e validada para uso em recém-nascidos a termo do Brasil submetidos a dor aguda. / Newborns in neonatal intensive care units routinely experience pain associated with invasive procedures. Pain assessment should provide data to define actions to alleviate neonatal pain. The Neonatal Infant Pain Scale is a pain assessment instrument for newborns validated in Canada and used in Brazil, although no cross-cultural adaptation and validation study had been previously performed for use in this country. In this study, the Neonatal Infant Pain Scale was adapted cross-culturally and validated clinically for use in Brazil. The steps recommended by Beaton for the cross-cultural adaptation of health measurement instruments were followed, including initial translations, synthesis of translations, back translations, review by an expert committee and testing of the pre-final version to ensure the equivalence between the original instrument and the translated version. The final adapted instrument was submitted to clinical validation to evaluate the retention of psychometric properties, validity, reliability and internal consistency. The study included 60 healthy term newborns that underwent painful procedures, which were video recorded and later evaluated by six nurses. Each recording was evaluated by two nurses (inter-rater reliability) and re-evaluated by one of them (intra-rater reliability). Clinical validation data were analyzed using the Student t test, the prevalence-adjusted bias-adjusted kappa (PABAK) coefficient, Bland-Altman plots and the Cronbach’s alpha coefficient. The study was conducted in the neonatology unit of a university hospital in Porto Alegre, Brazil, from September 2011 to September 2012. Ethical principles were followed, and the permission to use the scale was granted by its coauthor and the hospital that holds its rights. After translation and preparation of the pre-final version, 32 healthcare workers used a Likert-like scale to assess clarity, which was greater than 87.5%. The version adapted for use in Brazil, now called Escala de Dor no Recém-Nascido (NIPS Brazil) had good inter- and intra-rater reliability, PABAK was 0.93 for the agreement with total score, and inter- and intra-rater agreements were greater than 95% and 90% according to the Bland-Altman plots. Internal consistency was good, with a Cronbach’s alpha of 0.762. This study adapted the Neonatal Infant Pain Scale cross-culturally to Brazilian Portuguese and clinically validated it for use with Brazilian term newborns that experience acute pain. / Recién nacidos enfermos experimentan el dolor rutineramente asociado a procedimientos invasivos dentro de la Unidad de Terapia Intensiva Neonatal. La evaluación del dolor tiene como objetivo proveer datos para determinar acciones que alivien el dolor del neonato. La Neonatal Infant Pain Scale es una escala de evaluación del dolor para recién nacidos validada en Canadá y utilizada en Brasil, pero no hay un estudio de adaptación transcultural y validación para el país. Este estudio tuvo el objetivo de realizar la adaptación transcultural y validación clínica del instrumento Neonatal Infant Pain Scale para uso en Brasil. Se utilizaron los pasos propuestos por Beaton para adaptación transcultural de instrumentos de medida en salud, involucrando las etapas de traducción inicial, síntesis entre los traductores, retrotraducción, revisión por comité de especialistas y testaje de la versión pre-final a fin de garantizar equivalencia entre el instrumento original y la traducción. El instrumento final adaptado fue sometido a la validación clínica para evaluación del mantenimiento de las propiedades psicométricas de validad, confiabilidad y consistencia interna. La muestra consistió de 60 recién nacidos a término y saludables sometidos a un procedimiento doloroso que fue filmado y evaluado por seis enfermeros posteriormente, siendo que cada vídeo fue evaluado por dos enfermeros (confiabilidad interobservador) y reevaluado por uno de ellos (confiabilidad intraobservador). Para los datos de la validación clínica, fueron realizados los testes estadísticos t-student, coeficiente kappa ajustado por PABAK, método de Bland-Altman y coeficiente alfa de Cronbach. El estudio fue realizado en la unidad de neonatología de un hospital universitario de Porto Alegre, RS, entre septiembre de 2011 y septiembre de 2012. Los principios éticos fueron respetados y fue consentido permiso del hospital detentor de los derechos sobre la escala y de su coautor para el estudio. Después de la traducción y elaboración de la versión pre-final, su claridad fue evaluada por 32 profesionales de la salud a través de una escala likert, resultando en un nivel de claridad superior a 87,5%. La versión adaptada para el Brasil, ahora llamada Escala de Dor no Recém-Nascido (Escala de Dolor en el Recién Nacido) (NIPS - Brasil), demostró muy buena confiabilidad inter e intraobservador, con PABAK de 0,93 en la concordancia en relación al escore total, siendo que en el gráfico de Bland- Altman la concordancia inter e intraobservadores quedó arriba de 95% y 90%, respectivamente. La consistencia interna fue considerada buena, con alfa de Cronbach de 0,762. Se considera la adaptación transcultural de la Neonatal Infant Pain Scale para el portugués hablado en Brasil establecida y validada para uso en recién nacidos a término de Brasil sometidos a dolor agudo.
30

Vztah vysokých hladin interleukinu-6 v pupečníkové krvi novorozenců porodní váhy pod 1500g, k mortalitě, kraniální a plicní morbiditě a riziku neurosenzorického postižení / THE RELATIONSHIP BETWEN HIGH LEVELS OF INTERLEUKIN-6 IN CORD BLOOD OF NEWBORN WITH THE BIRTH WEIGHT UNDER 1500G AND MORTALITY, CRANIAL AND PULMONAL MORBIDITY AND RISK NEUROSENSORIC IMPAIREMENT

HANZL, Milan January 2009 (has links)
No description available.

Page generated in 0.0564 seconds