• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 7
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 32
  • 32
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Charakterisierung von dia-, para- und ferromagnetischen dünnen Schichten mittels magnetooptischer Kerr-Effekt-Spektroskopie

Fronk, Michael 13 September 2010 (has links)
Die polare magnetooptische Kerr-Effekt-Spektroskopie (MOKE) wird in dieser Arbeit zum ersten Mal zur Charakterisierung paramagnetischer Schichten eingesetzt. Die Schichten bestehen aus Phthalocyanin-Molekülen (H2Pc, VOPc, MnPc, CoPc und CuPc), die sich als Modellsystem zur Untersuchung des Einflusses des Molekülzentrums auf die elektronischen Zustände eignen. Die optischen Konstanten und die Dicken der Schichten werden mittels Ellipsometrie bestimmt. Mithilfe eines optischen Schichtmodells wird aus den Ellipsometrie- und MOKE-Daten die Voigt-Konstante, ein magnetooptischer Materialparameter, berechnet. Der Einfluss des Molekülzentrums auf die energetische Dispersion der Voigt-Konstante ist moderat. Vergleichsweise groß ist der Einfluss der Orientierung der Moleküle auf die Größe der Voigt-Konstante. Daher kann diese als Maß für den Aufstellwinkel des planaren CuPc herausgestellt werden. Darüber hinaus wird am Beispiel von CuPc gezeigt, dass sich die strukturelle Ordnung in molekularen Schichten mittels Reflexions-Anisotropie-Spektroskopie quantifizieren lässt. Die MOKE-Spektroskopie wird zusammmen mit MOKE-Magnetometrie auch zur Untersuchung von Eisen-Platin-Schichten mit Schichtdicken um 5 nm auf thermisch oxidiertem Silizium verwendet. Hier wird der Einfluss von eindiffundiertem Kupfer auf die magnetischen Eigenschaften Remanenz, Koerzitivität und magnetische Anisotropie der Schichten untersucht. Dabei wird neben der in Form einer Unterschicht bereitgestellten Kupfermenge die Temperatur variiert, bei der das Kupfer diffundiert. Die Magnetometrieuntersuchungen ergeben, dass Kupfer die magnetischen Eigenschaften der Eisen-Platin-Schichten verbessert, das Optimum des Kupfergehalts aber deutlich unter 20% liegt. Die optimale Mischtemperatur beträgt 600°C. Durch die Anwendung der MOKE-Spektroskopie wurde im Rahmen dieser Arbeit erstmals die Präsenz einer Feinstruktur der magnetooptischen Übergänge aus den 3d-Zuständen des Eisens entdeckt. Durch Vergleichsmessungen mit Schichten anderer Schichtdicke und auf anderen Substraten kann diese Feinstruktur mit mechanischen Verspannungen an der Grenzfläche zum Substrat in Verbindung gebracht werden.
32

Development of an Optical Scattering Measurement Device / Produktutveckling av ett optiskt mätinstrument

Grünwald, Ida, Gåhlin, Amanda January 2024 (has links)
Optical scattering measurement devices are used to measure light reflection and light scattering from materials, to obtain data of the surface and bulk properties of materials. The measurement data are often used in research and development projects where material requirements are important, also for quality control in manufacturing processes, in different optical simulations and can be used for photorealistic rendering. In this master thesis project conducted at AFRY, a multifunctional team will develop an optical scattering measurement device that aims to collect data more accurately than current devices on the market. This thesis will focus on the mechanical design of the device which consists of the stability and movement of the components, the environment of the measurements and material selection with a focus on performance and sustainability. The optical model that will act as a basis for the development will be a gonioreflectometer consisting of a material sample, sample holder, light source, detector and an environment in which the measurements are conducted. Some of the physical, cognitive and emotional needs of the intended user are efficient use, low risk of misuse, reliable and high precision. A thorough requirement specification was made as a framework for the concept generation. The selected concept provides the movement of the optical components with an angular step enabling the desired optical scattering measurement. The selected stepper motor and gear ratio provides the flexibility of the movement, making it easy for the user to change angular steps of the optical components, enabling both fine and rough measurements. A separating screen was chosen for both concepts in order to avoid light contamination between measurements and the material sample holder resembles a frame that allows for mounting the material sample outside of the device. The mechanical system has a high stability and the material black anodized aluminum further contributes to the sturdiness of the construction. A physical prototype was created to validate the movement, since the movement of the detector and light source will be similar, only the detector movement was prototyped. The prototype showed that the movement of the detector worked in the desired way, hence the construction of the movement is approved. The scope was delimited in consensus with the project members and supervisors due to the time frame, hence there is future work on the device that should be accounted for. In conclusion, the purpose of the project was fulfilled after delimiting the goals and a conceptual solution was created that fulfilled the requirements of the project. / Optiska mätinstrument används för att mäta ljusreflektion och ljusspridning från material, för att erhålla data om materialets yt- och bulkegenskaper. Mätdata används ofta i forsknings- och utvecklingsprojekt där materialkrav är viktiga, även för kvalitetskontroll i tillverkningsprocesser, i olika optiska simuleringar och kan användas för fotorealistisk rendering. I detta examensarbete, genomfört på AFRY, kommer ett multifunktionellt team att utveckla en optisk spridningsmätningsenhet som syftar till att samla in data mer noggrant. Denna avhandling kommer att fokusera på den mekaniska designen av enheten som består av stabiliteten och rörelsen av komponenterna, mätmiljön och materialval med fokus på prestanda och hållbarhet. Den optiska modellen som kommer att ligga till grund för utvecklingen kommer att vara en gonioreflektometer bestående av ett materialprov, provhållare, ljuskälla, detektor och en miljö där mätningarna genomförs. Några av de fysiska, kognitiva och emotionella behoven hos den avsedda användaren är effektiv användning, låg risk för felanvändning, pålitlighet och hög precision. En noggrann kravspecifikation gjordes som en ram för konceptgenereringen. Det valda konceptet möjliggör rörelse av de optiska komponenterna med ett vinkelsteg som tillåter den önskade optiska spridningsmätningen. Den valda stegmotorn och utväxlingen ger flexibilitet i rörelsen, detta bidrar till att det är enkelt för användaren att ändra vinkelstegen för de optiska komponenterna, vilket tillåter både fina och grova mätningar. En avskiljningsskärm valdes för att undvika ljuskontaminering mellan mätningarna och materialprovhållaren liknar en ram där materialprovet monteras utanför enheten. Det mekaniska systemet har en hög stabilitet och materialet svart anodiserad aluminium bidrar till konstruktionens robusthet. En fysisk prototyp skapades för att validera rörelsen, eftersom rörelsen av detektorn och ljuskällan kommer att vara liknande, återskapades endast detektorns rörelse. Prototypen visade att detektorns rörelse fungerade på önskat sätt, därmed godkänns konstruktionen av rörelsen. Projektets mål avgränsades i samförstånd med projektmedlemmarna och handledarna på grund av tidsramen, därmed finns det framtida arbete för mätinstrumentet som bör beaktas. Sammanfattningsvis uppfylldes projektets syfte efter att målen avgränsats och en konceptuell lösning skapades som uppfyllde projektets krav.

Page generated in 0.077 seconds