• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 45
  • 10
  • 5
  • 5
  • 4
  • 2
  • 2
  • Tagged with
  • 158
  • 158
  • 147
  • 71
  • 58
  • 50
  • 35
  • 34
  • 33
  • 30
  • 23
  • 21
  • 21
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Desenvolvimento de método de quantificação de estatinas em efluente hospitalar e estudo de degradação oxidativa avançada / Method development of statins quantification in hospital effluent and study of advanced oxidative degradation

Altissimo, Joseline 18 December 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this study, an analytical method was developed for the quantification of statins Atorvastatin and Simvastatin, in hospital effluent (University Hospital of Santa Maria, using Solid phase extraction and Dispersive liquid-liquid microextraction, followed in liquid chromatography coupled to diode array detector. The principal variables of Dispersive liquid-liquid microextraction were investigated with aid of experimental central composite design. The recovery rates of Solid phase extraction varied from 95% for Atorvastatin and 83.2% for Simvastatin, in aqueous solution, and 92.0% for Atorvastatin and 81.5% for Simvastatin, in hospital effluent. As for the Dispersive liquid-liquid microextraction the recovery rates ranged from 85.5% for Atorvastatin and 89.4% for Simvastatin, in aqueous solution, and 83.0% for Atorvastatin and 83.1% for Simvastatin, in hospital effluent. The sampling was carried out in two sample points called Emergency Effluent and General Effluent . The concentration rates detected in the effluent were 30.1 μg L-1 in Emergency Effluent and 29.0 μg L-1 in General Effluent for Atorvastatin and 37.1 μg L-1 in Emergency Effluent and 36.1 μg L-1 in GE for Simvastatin. Ozonation and electrocoagulation were applied for the degradation/removal of statins. The principal variables of electrocoagulation were investigated with aid of experimental central composite design. The degradation rate obtained in ozonation was 100% for Atorvastatin, in 25 minutes reaction for aqueous solution and hospital effluent; and 100% for Simvastatin, in 4 minutes reaction for aqueous solution and 10 minutes reaction in hospital effluent. As for the electrocoagulation the removal rate was 75.6% in aqueous solution and 70.9% in hospital effluent for Atorvastatin; and 100% in aqueous solution and hospital effluent for Simvastatin in 60 minutes reaction. A preliminary risk evaluation revealed that the statins showed a low environmental risk, PEC/PNEC < 1. / Neste trabalho foi desenvolvida metodologia analítica para a quantificação de estatinas Atorvastatina e Sinvastatina, em efluente hospitalar (Hospital Universitário de Santa Maria), utilizando Extração em fase sólida e Microextração dispersiva líquido-líquido seguida de cromatografia líquida com detector de arranjo de diodos. As principais variáveis da Microextração dispersiva líquido-líquido foram investigadas utilizando a Metodologia de Superfície de Resposta através de um delineamento composto central rotacional. As taxas de recuperação da Extração em fase sólida foram de 95,8% para Atorvastatina e 83,5% para Sinvastatina, em solução aquosa e 92,0% para Atorvastatina e 81,5% para Sinvastatina em efluente hospitalar. Já para a Microextração dispersiva líquido-líquido as taxas de recuperação foram de 85,5% para Atorvastatina e 89,4% para Sinvastatina, em solução aquosa e 83,0% para Atorvastatina e 83,1% para Sinvastatina, em efluente hospitalar. A amostragem foi feita em dois pontos de coleta, denominados Efluente PA e Efluente Geral . A concentração média detectada no efluente foi de 30,1 μg L-1 no Efluente PA e 29,0 μg L-1 no Efluente Geral para Atorvastatina e 37,1 μg L-1 no Efluente PA e 36,1 μg L-1 no Efluente Geral para Sinvastatina. Ozonização e eletrocoagulação foram aplicados na degradação/remoção das estatinas. As principais variáveis da eletrocoagulação foram investigadas utilizando a Metodologia de Superfície de Resposta através de um delineamento composto central. As taxas de degradação obtidas na ozonização foram de 100% para Atorvastatina, em 25 min de reação, para solução aquosa e efluente hospitalar; e 100% para Sinvastatina em 4 min em solução aquosa, e 10 min em efluente hospitalar. Já para a eletrocoagulação as taxas de remoção foram de 75,9% em solução aquosa e 70,9% em efluente hospitalar para Atorvastatina; e 100% para solução aquosa e afluente hospitalar para Sinvastatina, em 60 min de reação. A análise preliminar de risco ambiental revelou que as estatinas apresentam baixo risco ambiental, com PEC/PNEC < 1.
142

Desenvolvimento de um reator fotoqu?mico aplic?vel no tratamento de efluentes fen?licos presentes na ind?stria do petr?leo / Development of a photochemistry reactor applicable in the treatment of phenolic wastewaters present in the petroleum industry

Mota, Andr? Lu?s Novais 02 December 2005 (has links)
Made available in DSpace on 2014-12-17T15:01:16Z (GMT). No. of bitstreams: 1 AndreLNM.pdf: 781178 bytes, checksum: d7b742a561481a98abbefe98cb97f8fb (MD5) Previous issue date: 2005-12-02 / With water pollution increment at the last years, so many progresses in researches about treatment of contaminated waters have been developed. In wastewaters containing highly toxic organic compounds, which the biological treatment cannot be applied, the Advanced Oxidation Processes (AOP) is an alternative for degradation of nonbiodegradable and toxic organic substances, because theses processes are generation of hydroxyl radical based on, a highly reactivate substance, with ability to degradate practically all classes of organic compounds. In general, the AOP request use of special ultraviolet (UV) lamps into the reactors. These lamps present a high electric power demand, consisting one of the largest problems for the application of these processes in industrial scale. This work involves the development of a new photochemistry reactor composed of 12 low cost black light fluorescent lamps (SYLVANIA, black light, 40 W) as UV radiation source. The studied process was the photo-Fenton system, a combination of ferrous ions, hydrogen peroxide, and UV radiation, it has been employed for the degradation of a synthetic wastewater containing phenol as pollutant model, one of the main pollutants in the petroleum industry. Preliminary experiments were carrier on to estimate operational conditions of the reactor, besides the effects of the intensity of radiation source and lamp distribution into the reactor. Samples were collected during the experiments and analyzed for determining to dissolved organic carbon (DOC) content, using a TOC analyzer Shimadzu 5000A. The High Performance Liquid Chromatography (HPLC) was also used for identification of the cathecol and hydroquinone formed during the degradation process of the phenol. The actinometry indicated 9,06&#8901;1018 foton&#8901;s-1 of photons flow, for 12 actived lamps. A factorial experimental design was elaborated which it was possible to evaluate the influence of the reactants concentration (Fe2+ and H2O2) and to determine the most favorable experimental conditions ([Fe2+] = 1,6 mM and [H2O2] = 150,5 mM). It was verified the increase of ferrous ions concentration is favorable to process until reaching a limit when the increase of ferrous ions presents a negative effect. The H2O2 exhibited a positive effect, however, in high concentrations, reaching a maximum ratio degradation. The mathematical modeling of the process was accomplished using the artificial neural network technique / Com o crescente aumento da polui??o das ?guas acorrido nos ?ltimos anos, houve tamb?m um grande avan?o das pesquisas relacionadas ao tratamento de ?guas contaminadas. Efluentes contendo compostos org?nicos de alta toxicidade, nos quais o tratamento biol?gico n?o pode ser aplicado, os chamados processos oxidativos avan?ados (POA) surgem como uma alternativa para a degrada??o de subst?ncias org?nicas t?xicas n?o biodegrad?veis, pois estes processos s?o baseados na gera??o de radicais hidroxila, subst?ncias altamente reativas, capazes de degradar praticamente todas as classes de compostos org?nicos. Os POA, por muitas vezes, requerem o uso de reatores com l?mpadas especiais que emitem luz ultravioleta. Estas l?mpadas apresentam uma alta demanda de energia el?trica, consistindo, portanto, em um dos maiores problemas para a aplica??o desses processos em escala industrial. Este trabalho envolveu o desenvolvimento de um novo reator fotoqu?mico composto de 12 l?mpadas fluorescentes de luz negra de baixo custo como fonte de radia??o UV. O processo estudado foi o sistema foto-Fenton, uma combina??o de ?ons ferrosos, per?xido de hidrog?nio e radia??o ultravioleta, sendo aplicado na degrada??o de um efluente sint?tico aquoso contendo fenol, um dos principais poluentes da ind?stria do petr?leo. Foram realizados experimentos preliminares visando avaliar as condi??es operacionais do reator, al?m dos efeitos da intensidade da fonte de radia??o e distribui??o das l?mpadas no reator. As amostras foram analisadas quanto ao teor de carbono org?nico dissolvido (COD) utilizando um TOC 5000A da Shimadzu. A partir do recurso da cromatografia l?quida de alto desempenho (HPLC), p?de ser identificado a forma??o do catecol e da hidroquinona durante o processo de degrada??o do fenol. Pelo emprego da actinometria foi obtida uma taxa de incid?ncia de f?tons de 9,06&#8901;1018 foton&#8901;s-1, para 12 l?mpadas acionadas. Foi elaborado um planejamento fatorial ampliado do qual foi poss?vel avaliar a influ?ncia da concentra??o dos reagentes (Fe2+ e H2O2), al?m de ter sido determinado as condi??es ?timas experimentais ([Fe2+] = 1,6 mM e [H2O2] = 150,5 mM), obtendo um percentual m?ximo de degrada??o de 81,38 % em 1 hora de rea??o. Foi verificado que o aumento da concentra??o dos ?ons ferrosos ? favor?vel ao processo at? atingir um limite, quando o acr?scimo de ?ons ferrosos come?ou a apresentar um efeito negativo. O H2O2 apresentou um efeito positivo ao processo, atingindo um percentual m?ximo de degrada??o. A modelagem matem?tica do processo foi realizada utilizando o recurso da rede neural artificial, a qual p?de representar o sistema e o comportamento das vari?veis do processo
143

Avaliação de parâmetros operacionais na cinética de degradação do antibiótico ciprofloxacino pelo processo foto-fenton

Santos, Lucilene Cândida dos 29 August 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this work the degradation of the antibiotic ciprofloxacin CIP (33.1 mg L-1) by photo- Fenton process using artificial radiation was evaluated. First, the effect of different concentrations of Fe 3+ (1.4, 5.6, 11.2 and 16.8 mg L -1) on the kinetics of CIP and dissolved organic carbon DOC (mineralization), as well as the consumption of H2O2 using 510 mg L-1 of H2O2and pH 2.5-2.8 was studied. The CIP concentration was below of the quantitation limit of the equipment - LQ (<0.163 mg L-1) in just 2 minutes, for all concentration of Fe3+ evaluated, it was not possible to verify the effect of this operating parameter for the removal of CIP. Regarding the results of mineralization and consumption of H2O2, the best fit mathematical observed for all the experimental data obtained at different concentrations of Fe3+ evaluated, was first order. Furthermore, it was observed that the concentration of Fe3+ resulted in a proportional increase in the rate of mineralization and consumption of H2O2, being the concentration of 11.2 mg L-1 of Fe3+ chosen for the subsequent experiments. Next, the effect of different concentrations of H2O2 (85, 170, 340, 510 and 680 mg L-1) on kinetics of CIP mineralization and consumption of H2O2 using the best concentration of Fe3+ (11.2 mg L-1), and at pH 2.5-2.8 was evaluated. Similar behavior observed for the different concentrations of Fe3+ was obtained, the best mathematical fit for CIP mineralization and H2O2 consumption was of first order. The rate of CIP mineralization also increased proportionally with H2O2 concentration, but up to a certain amount of H2O2 (340 mg L-1). Above of this concentration, there was a decrease in the rate of mineralization due to the occurrence of inefficient reactions. These results demonstrate the importance of evaluating the operational parameters, such as the concentrations of Fenton´s reagents, in order to optimize the efficiency of the photodegradation process, as well as reduce the costs of processes with chemical reagents. Thus, the best concentrations obtained experimentally in deionized water (DW) in relation to the operational parameters evaluated considering the CIP mineralization using artificial radiation were: [Fe3+] = 11.2 mg L-1 and [H2O2] = 340 mg L-1. Under these experimental conditions, the influence of different aqueous matrices (simulated seawater - SW and treated effluent from sewage treatment plant - STP) in the CIP degradation was evaluated, and the results were compared to those obtained in DW. Complete removal of CIP (considering the LQ equipment) was influenced by the composition of the matrices, since in DW occurred after 2 minutes of the photo-Fenton process, while 10 minutes were required in SW and STP effluent. This is probably due to the presence of inorganic anions (chloride and sulphate) in SW, which form stable complexes with iron, and also act as scavengers of hydroxyl radicals, as well as by the presence of natural organic matter present in the effluent of STP, which also competes with the target-compound by hydroxyl radicals, influencing the degradation process. Based on the results obtained in this work, it was observed that the photo-Fenton process can be an alternative of treatment to waters containing CIP, since there was complete removal of CIP (considering the LQ equipment) after only 2 minutes, followed by 75% of DOC removal and reduction of acute toxicity to A. saline from 76.7% ± 4.7% to 20.0% ± 10.0% after 60 minutes. Since several ecotoxicological effects are associated with waste pharmaceuticals, in specific antibiotics, in aquatic environments and conventional processes fail to remove them efficiently, the application of this process appears quite feasible. / Neste trabalho foi avaliada a degradação do antibiótico ciprofloxacino CIP (33,1mg L-1)pelo processo foto-Fenton utilizando radiação artificial. Primeiramente avaliou-se diferentes concentrações de Fe3+ (1,4, 5,6, 11,2 e 16,8 mg L-1) na cinética de remoção de CIP e carbono orgânico dissolvido - COD (mineralização), bem como no consumo de H2O2 utilizando-se 510 mg L-1 de H2O2 e pH 2,5-2,8. A concentração de CIP ficou abaixo do limite de quantificação do equipamento - LQ (< 0,163 mg L-1) em apenas 2 minutos, para todas as concentrações de Fe3+ avaliadas, não sendo possível verificar o efeito deste parâmetro operacional para a remoção de CIP. Em relação aos resultados de mineralização e consumo de H2O2, o melhor ajuste matemático observado para todos os dados experimentais obtidos nos diferentes níveis de concentração de Fe3+ avaliados foi de primeira ordem. Além disso, foi observado que o aumento da concentração de Fe3+ resultou num aumento proporcional na velocidade de mineralização e de consumo de H2O2, sendo a concentração de 11,2 mg L-1 de Fe3+ escolhida para os experimentos posteriores. A seguir, foi avaliado o efeito de diferentes concentrações de H2O2 (85, 170, 340, 510 e 680 mg L-1) na cinética de mineralização de CIP e consumo de H2O2 utilizando a melhor concentração de Fe3+ (11,2 mg L-1), e, em pH 2,5-2,8. Comportamento semelhante ao observado para as diferentes concentrações de Fe3+ foi obtido, melhor ajuste matemático para a mineralização de CIP e consumo de H2O2 sendo de primeira ordem. A velocidade de mineralização de CIP também aumentou proporcionalmente com a concentração de H2O2, contudo até um determinado valor de H2O2 (340 mg L-1). Acima desta concentração, houve um decréscimo na velocidade de mineralização devido à ocorrência de reações ineficientes. Estes resultados, demonstram a importância de avaliar os parâmetros operacionais, tais como as concentrações dos reagentes de Fenton, a fim de otimizar a eficiência do processo de fotodegradação, bem como reduzir os custos dos processos com reagentes químicos. Assim, as melhores concentrações obtidas experimentalmente em água deionizada (AD) em relação aos parâmetros operacionais avaliados considerando a mineralização de CIP utilizando radiação artificial foram: [Fe3+] = 11,2 mg L-1 e [H2O2] = 340 mg L-1. Sob tais condições experimentais, a influência de diferentes matrizes aquosas (água de mar simulada AM, e, efluente tratado de estação de tratamento de esgoto - ETE) na degradação de CIP foi avaliada, e os resultados foram comparados aos obtidos em AD. A completa remoção de CIP (considerando o LQ do equipamento) foi influenciada pela composição da matriz, uma vez que em AD ocorreu após 2 minutos do processo foto-Fenton, enquanto que 10 minutos foram necessários para a AM e efluente de ETE. Isto ocorreu provavelmente devido à presença de ânions inorgânicos (cloreto e sulfato) em AM, os quais formam complexos estáveis com ferro, e que também atuam como sequestradores de radicais hidroxilas, assim como pela presença de matéria orgânica natural presente no efluente de ETE, a qual também compete com o composto-alvo pelos radicais hidroxila, influenciando assim o processo de degradação. Baseado nos resultados obtidos neste trabalho pode ser observado que o processo foto-Fenton pode ser uma alternativa de tratamento de águas contendo CIP, pois houve completa remoção de CIP (considerando o LQ do equipamento) após apenas 2 minutos, seguido de 75% de remoção de COD e redução da toxicidade aguda para A. salina de 76,7% ± 4,7% para 20,0% ± 10,0% após 60 minutos. Visto que vários efeitos ecotoxicológicos estão associados aos resíduos de fármacos, em específico antibióticos, presentes nos ambientes aquáticos e que os processos convencionais não conseguem removê-los eficientemente, a aplicação deste processo se mostra bastante viável. / Mestre em Química
144

Degradação do antibiótico ciprofloxacina em solução aquosa por meio de processo oxidativo avançado baseado em ozônio. / Degradation of the antibiotic ciprofloxacin in aqueous solution by the advanced oxidation process based on ozone.

Cíntia Bardauil Baptistucci 02 March 2012 (has links)
Os tratamentos convencionais de efluentes em geral não são eficientes para a degradação de compostos persistentes como os fármacos. Neste trabalho, estuda-se o tratamento de soluções aquosas contendo o antibiótico ciprofloxacina (CIP) por meio de processo oxidativo avançado baseado em ozônio. Para tanto, foram realizados experimentos em semi-batelada com recirculação de líquido em um reator (coluna de bolhas) com escoamento gás-líquido em contracorrente. Amostras de líquido foram retiradas e analisadas para medida das concentrações de CIP e de carbono orgânico total (COT); a concentração de ozônio no gás foi medida por espectrofotometria UV-vis. Estudaram-se os efeitos das seguintes variáveis quanto à degradação de CIP, por meio de um planejamento Doehlert: concentração de ozônio à entrada do reator (8-25 mgO3 L-1), pH (3,5-10,5) e concentração inicial de CIP (5-26 mg L-1). Avaliaram-se as seguintes variáveis dependentes por meio da análise de superfícies de resposta: variação de concentração de CIP em 2 minutos; taxa inicial de degradação de CIP e variação de concentração de COT em 30 minutos. Os resultados indicaram total degradação de ciprofloxacina em menos de 15 minutos, tanto por via direta, com ataque por ozônio molecular em meio ácido, como por via indireta, com ataque por radicais hidroxila em meio básico. Os compostos resultantes da degradação da CIP mostraram-se recalcitrantes, obtendo-se maiores remoções de COT após 30 minutos apenas em meio básico ou neutro (máximo de 72,8% para pH=7, [O3]=24,9 mgO3 L-1 e [CIP]0=15,8 mg L-1). Apesar da persistência dos compostos orgânicos remanescentes, os ensaios respirométricos sugeriram que os produtos de degradação são menos tóxicos que o composto de partida, com menor inibição da atividade microbiana. No conjunto, os resultados do trabalho indicam que o processo de ozonização pode ser aplicado para pré-tratamento de efluentes aquosos contendo ciprofloxacina em baixas concentrações, podendo ser associado a processos de tratamento biológico em ETEs antes do descarte. / Conventional wastewater treatment processes are not generally efficient for the degradation of persistent substances like pharmaceutical compounds. In this work, the treatment of aqueous solutions containing the antibiotic ciprofloxacin (CIP) by means of the ozone-based advanced oxidation process is studied. With this aim, experiments were carried out in semi-batch mode with liquid circulation in a bubble column reactor with gas-liquid counter flow. Liquid samples were analyzed for CIP and total organic carbon (TOC) concentrations; ozone concentration in the gas was measured by UVvisible spectrophotometry. The effects of the following variables on CIP degradation were studied according to a Doehlert experimental design: inlet ozone concentration (8 to 25 mgO3 L-1), pH (3.5 to 10.5), initial CIP concentration (5 to 26 mg L-1). The following dependent variables were investigated by response surface analysis: variation in CIP concentration after 2 minutes; CIP initial degradation rate and variation in TOC concentration after 30 minutes. The results showed total degradation of ciprofloxacin in less than 15 minutes either by direct reaction with molecular ozone in acidic medium, or by indirect attack of hydroxyl radicals in alkaline medium. Compounds resulting from CIP degradation showed to be recalcitrant, yielding larger TOC removals after 30 minutes only in alkaline or neutral medium (maximum of 72.8% for pH=7, [O3]=24.9 mgO3 L-1, and [CIP]0=15.8 mg L-1). Despite the persistence of remaining organic compounds, respirometric assays suggested that degradation products are less toxic than the parent compound, exhibiting lower inhibition of microbial activity. Overall, the results indicate that the ozonation process can be used in the pre-treatment of aqueous effluents containing ciprofloxacin in low concentrations, and could be associated with biological treatment processes in wastewater treatment plants prior to final disposal.
145

Processos de tratamento não convencionais para degradação do antibiótico sulfadiazina em meio aquoso. / Non-conventional treatment processes for the degradation of the antibiotic sulfadiazine in aqueous medium.

Arlen Mabel Lastre Acosta 25 April 2016 (has links)
A presença de antibióticos no meio ambiente aquático tem causado crescente preocupação mundial. Além dos relatos de resistência de bactérias a antibióticos, essa classe de fármacos também pode causar efeitos tóxicos e atuar como perturbadores endócrinos em diversos organismos vivos e, possivelmente, em humanos. Dentre os antibióticos comumente usados destacam-se as sulfonamidas, detectadas em águas subterrâneas e superficiais. Os processos avançados de oxidação (POA) têm sido apontados como tecnologias eficientes para tratamento de poluentes recalcitrantes em diferentes matrizes aquosas. Dentre os POA, o processo foto-Fenton é uma alternativa para a degradação de compostos não biodegradáveis, incluindo fármacos. Uma vez que a principal limitação do processo é o intervalo de pH (2,5- 4,0), a reação pode ser vantajosamente conduzida empregando-se substâncias bio-orgânicas solúveis (BOS) como agentes complexantes de Fe3+ em condições ligeiramente ácidas (pH 5). Por sua vez, o emprego da energia ultrassônica tem sido menos estudado. Nesse contexto, o objetivo deste trabalho é estudar a degradação do antibiótico sulfadiazina (SDZ) por meio do processo foto-Fenton na presença de substâncias bio-orgânicas solúveis (UVvis/ Fe3+/H2O2/BOS) e do processo de cavitação por meio de ultrassom (US). Os resultados obtidos mostram que a sulfadiazina é eficientemente degradada por ultrassom de alta frequência. As maiores porcentagens e taxas de remoção são obtidas usando menor frequência de operação (580 kHz), maior potência dissipada e em pH ligeiramente ácido (melhor condição: pH 5,5). Além disso, a reação de Fenton, combinada com o tratamento US, melhorou notavelmente a degradação da SDZ, particularmente quando quantidades extras de H2O2 foram adicionadas ao sistema. Por sua vez, o uso de BOS como aditivos no processo foto-Fenton apresenta influência marcante na fotodegradação da SDZ em condições ligeiramente ácidas (pH 5). Os BOS podem estabilizar espécies de ferro em solução aquosa em pH próximos ao neutro, o que constitui uma propriedade de grande interesse. Sob as condições estudadas, o BOS CVT230 foi mais eficiente do que FORSUD, provavelmente devido às diferenças nos grupos funcionais presentes na composição destas substâncias. Finalmente, foram calculados os indicadores de consumo de energia elétrica por ordem de grandeza (EEO) para o processo de ultrassom (1572 kW h m-3 ordem-1) e área do coletor por ordem de grandeza (ACO) para o processo foto-Fenton (8,07 m2 m-3 ordem-1). / The potential impacts of antibiotic residues in the environment have become an emerging concern during recent years due to their relation with the development of resistant bacteria, and in some cases to their ability to cause toxic and endocrine disrupting effects in humans and other living organisms. Highlighted among the commonly used antibiotics are the sulfonamides, detected in groundwater and surface water. Advanced oxidation processes (AOP) might constitute an important alternative to deal with pharmaceuticals degradation. Among them, the photo-Fenton process has been widely used. One of its major drawbacks is the highly acidic pH needed (2,5-4,0) to avoid the formation of photochemically inactive iron oxides and hydroxides. The ability of soluble bio-organic substances (SBO) to complex metal cations such as iron is useful for the development of photo-Fenton at mild acidic conditions (pH 5). In turn, the use of ultrasonic energy has been less studied. In this context, the aim of this work is to study the degradation of the antibiotic sulfadiazine (SDZ) by the photo-Fenton process in the presence of soluble bio-organic substances (UV-vis/Fe3+/H2O2/SBO) and by ultrasonic cavitation (US). The results confirm that SDZ is effectively degraded by highfrequency ultrasound. Higher SDZ percent removals and removal rates were observed for the lowest operating frequency (580 kHz), higher dissipated power, and in slightly acidic solution (pH 5.5). On the other hand, SDZ degradation is highly improved in the case of the US/ Fe(II)/H2O2 system. The use of the SBO as Fenton additives in turn has a remarkable influence in SDZ photodegradation at slightly acid conditions (pH 5). This could be ascertained to the complexation of iron by the SBO, hence maintained in the reaction medium as a photoactive species. Under the studied conditions, the BOS CVT230 was more efficient than FORSUD, probably due to differences in the functional groups present in the composition of these substances. Finally, the figures-of merit electrical energy per order (EEO) and collector area per order (ACO) were calculated for the ultrasound (1572 kW h m-3 ordem-1) and photo-Fenton (8,07 m2 m-3 ordem-1) processes respectively.
146

Βeta-bloqueadores em efluente hospitalar: ocorrência, degradação por processos avançados de oxidação e identificação de subprodutos / Βeta-blockers in hospital wastewater; occurence, degradation by advanced oxidation process and byproducts identification

Wilde, Marcelo Luís 15 December 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / β-Blockers are an important group of prescription drugs; as a consequence of the large and continuous use, they are commonly found in the environment. This study assessed, preliminary, the inherent risk of the β-blockers Atenolol, Metoprolol and Propranolol, mostly used in the University Hospital of Santa Maria (HUSM), and showed that Propranolol has high Risk Quotient (RQ) of 0.56. HPLC-FLD and SPE methodologies were developed and optimized with the aid of experimental design in order to analyze the occurrence of β-blockers in the HUSM sewage system. The average concentration for Atenolol, Metoprolol and Propranolol found for a week sampling were 2.45, 4.67 and 0.70 μg L-1 in the sewage of the Emergence; 0.95, 0.70 and 0.315 μg L-1 in the HUSM main sewage, and 1.26, 1.27 and 0.56 μg L-1 in the water course receptor, respectively, As possible remediation methodologies for the Hospital Wastewater (HWW) were investigated Advanced Oxidation Process (AOPs) such as photo-Fenton, K2FeO4, Ozonation and O3/Fe2+. The operational parameters were optimized by Response Surface Methodology (RSM). Using optimized conditions for photo-Fenton, Atenolol, Metoprolol and Propranolol were totally degraded in 5 min in aqueous solution, and the mineralization achieved 80% after 120 min of treatment. In HWW, the β-blockers were also totally degraded, however, only 26.5% of the organic matter and 38.6% of the aromaticity were removed. The ready biodegradability and toxicity of the photo-Fenton s samples were estimated by official methods, which indicated an increase in the biodegradability and toxicity. This behavior may be correlated to the formation of degradation products (DPs), relatively, more toxic. The DPs were identified with aid of Liquid Chromatography tandem Mass Spectrometry (LC-MSn). Other proposed degradation process was oxidation-coagulation using Fe(VI), which achieved above 90% degradation for Atenolol, Metoprolol and Propranolol in HWW, while only 17% COD and 60% aromaticity removal. In aqueous solution this process led to 71.7%, 24.7% and 96.5% degradation of Atenolol, Metoprolol and Propranolol, respectively. No mineralization was found, indicating the formation of DPs, identified by LC-MSn. The ready biodegradability of the post-process samples was tested and the results showed that the oxidation-coagulation with Fe(VI) increased the biodegradability. The applicability of ozonation was evaluated varying the pH (3-11) for HWW and aqueous solution. More than 95% of the β-blockers were degraded independently of the initial pH, while above 50% of the aromaticity was removed. In aqueous solution the β-blockers were degraded in 10 min treatment and the identification of the DPs were carried out for process pH 5, 7 and 9. Catalytic ozonation (O3/Fe2+) was applied to HWW and a mineralization of 49% was achieved, with 77.9% aromaticity removal. The β-blockers were totally degraded. Therefore, the present study represents a high qualified analytical information contribution concerning the occurrence of β-blockers in HWW. The studied AOPs/Fe(VI) processes demonstrated to be suitable to degrade Atenolol, Metoprolol and Propranolol. Moreover, high removal of organic matter and aromaticity were achieved by appling O3/Fe2+ process. In many aspects, this work can be considered original, in especial, by regarding the application of Ferrate(VI) and Catalytic Ozonation to the degradation of β-blockers in HWW. / Os β-bloqueadores são uma importante classe de fármacos prescritos na terapia de doenças cardiovasculares e como consequência de seu grande e contínuo uso são comumente encontrados no meio ambiente. O presente estudo avaliou preliminarmente o risco inerente dos β-bloqueadores mais usados no Hospital Universitário de Santa Maria (HUSM), Atenolol, Metoprolol e Propranolol, evidenciando que Propranolol apresentou maior risco inerente com Quociente de Risco teórico de 0,56 (risco médio). Métodos HPLC-FLD e de clean-up/pré-concentração por SPE foram desenvolvidos e otimizados com auxílio de Metodologia de Superfície de Resposta (RSM) para avaliar a ocorrência de β-bloqueadores no sistema de esgotos do HUSM. A concentração ambiental mensurada para Atenolol, Metoprolol e Propranolol durante um ciclo semanal no ponto de lançamento Efluente PA foi 2,45; 4,67 e 0,70 μg L-1, no ponto HUSM principal 0,95; 0,70 e 0,32 μg L-1 e para o Córrego onde os efluentes são lançados de 1,26; 1,27 e 0,56 μg L-1, respectivamente. Como metodologia de remediação da contaminação de β-bloqueadores em Efluente Hospitalar (EH) foram investigados os Processos Avançados de Oxidação (PAOs) Foto-Fenton, K2FeO4, Ozonização e O3/Fe2+. Os parâmetros operacionais foram otimizados por RSM. Usando as condições otimizadas para o processo Foto-Fenton, Atenolol, Metoprolol e Propranolol foram totalmente degradados em 120 min de tratamento, contudo somente 26,5 e 38,6% da carga orgânica e aromaticidade, respectivamente, foram removidos em EH. A pronta biodegradabilidade e toxicidade para amostras aquosas do processo Foto-Fenton foram analisadas por métodos oficiais e indicaram aumento na biodegradabilidade e toxicidade. Este comportamento esta relacionado à formação de Produtos de Degradação (PD) relativamente mais tóxicos. Os PDs foram identificados por Cromatografia Líquida acoplada a Espectrometria de Massas (LC-MSn). Outro processo proposto foi oxidação-coagulação com Fe(VI) que alcançou degradação de Atenolol, Metoprolol e Propranolol acima de 90% em EH, enquanto apenas 17 e 60% da matéria orgânica e aromaticidade foram removidos, respectivamente. Em solução aquosa este processo conduziu a degradação de 71,7; 24,7 e 96,5% de Atenolol, Metoprolol e Propranolol, respectivamente. Nenhuma mineralização foi encontrada indicando a formação de PDs, identificados por LC-MSn. A pronta biodegradabilidade para as amostras aquosas pós-processo foram avaliadas e os resultados encontrados mostraram que houve aumento na biodegradabilidade. A aplicabilidade de ozonização foi avaliada variando o pH de 3-11 em EH e solução aquosa. Mais de 95% dos β-bloqueadores foram degradados independente do pH inicial, enquanto mais de 50% da aromaticidade e 30% da matéria orgânica foram. Em solução aquosa todos os β-bloqueadores foram degradados em menos de 10 min e para os processos em pH 5, 7 e 9 foram identificados os PDs. O processo de O3/Fe2+ alcançou 49% de remoção de matéria orgânica, 77,9% de redução da aromaticidade e completa degradação de Atenolol, Metoprolol e Propranolol em EH. Portanto, o presente estudo contribui com informação analítica qualificada sobre a ocorrência de β-bloqueadores em EH. Os processos de degradação estudados mostraram-se adequados para a degradação de Atenolol, Metoprolol e Propranolol. Ademais, a maior remoção de matéria orgânica e aromaticidade foram observadas para o processo de O3/Fe2+. Em muitos aspectos, este trabalho pode ser considerado original, em especial sobre a aplicação de ferrato(VI) e ozonização catalítica para a degradação de β-bloqueadores em EH.
147

Eliminación de contaminantes orgánicos emergentes mediante procesos electroquímicos de oxidación avanzada.

Mora Gómez, Julia 10 January 2021 (has links)
[ES] La presente Tesis Doctoral se centra en el estudio del comportamiento electroquímico de nuevos electrodos cerámicos basados en SnO2 dopado con Sb2O3. El estudio está orientado a la posterior aplicación de estos electrodos en procesos electroquímicos de oxidación avanzada. Inicialmente, se consideraron diferentes temperaturas de sinterización (entre 1050°C y 1250°C) y se observó que un aumento en la temperatura de sinterización favorecía la deposición del Sb2O3 en la superficie anódica, disminuyendo así la resistividad del electrodo. Posteriormente, se estudió el comportamiento electroquímico de estos nuevos electrodos obteniendo el potencial de descarga del oxígeno mediante la técnica de voltametría de barrido lineal. Los resultados obtenidos revelaron que el valor del potencial de descarga del oxígeno disminuye con el aumento de la temperatura de sinterización. Además, estos electrodos presentaron un comportamiento intermedio entre el ánodo de Pt y el ánodo de BDD. Este último electrodo se emplea habitualmente en los procesos electroquímicos de oxidación avanzada debido a su elevada capacidad para generar radicales hidroxilo, los cuales son capaces de oxidar los compuestos orgánicos a dióxido de carbono y agua. A continuación, se llevaron a cabo ensayos de oxidación electroquímica con estos electrodos cerámicos para seleccionar la temperatura de sinterización. Los resultados mostraron que con el electrodo cerámico sinterizado a 1250°C se alcanza una menor degradación del compuesto orgánico, mientras que los electrodos sinterizados a menores temperaturas presentan un comportamiento similar entre ellos. Por tanto, se seleccionó el electrodo cerámico sinterizado a 1200°C ya que presenta una baja resistividad y un buen comportamiento electroquímico para ser utilizado como ánodo en los procesos electroquímicos de oxidación avanzada. Seguidamente se analizó la vida útil de estos electrodos cerámicos, y se comprobó que la matriz cerámica incrementa en gran medida la estabilidad a la polarización anódica de los electrodos basados en SnO2. Posteriormente, se llevaron a cabo procesos de electro-oxidación en modo galvanostático de distintos contaminantes difíciles de eliminar por las técnicas convencionales utilizando como ánodo los nuevos electrodos cerámicos y el electrodo de BDD, para así poder comparar los resultados obtenidos. Se observó que, aunque con los electrodos cerámicos se consigue degradar el 100% de los distintos contaminantes, el electrodo de BDD es el más eficiente ya que genera mayor cantidad de especies oxidantes activas en su superficie. Para un mismo electrodo, se observó que un aumento en la densidad de corriente aplicada mejora la velocidad de degradación y mineralización de cada contaminante, mientras que la eficiencia eléctrica disminuye. Por otro lado, se estudió el efecto de la presencia de una membrana de intercambio catiónico entre ánodo y cátodo. Los resultados mostraron que el uso de la membrana beneficia la degradación y la mineralización del contaminante, ya que mejora la cinética de reacción anódica y evita la reducción de las especies oxidantes electrogeneradas. A continuación, se analizó la influencia de la concentración del Na2SO4 como electrolito soporte. En este estudio se observó que un aumento en la concentración del Na2SO4 mejora la mineralización del contaminante para el electrodo de BDD y, por el contrario, empeora para el electrodo cerámico. Esto se debe a la capacidad de cada electrodo para oxidar los sulfatos a persulfatos. Por último, se llevaron a cabo ensayos de ecotoxicidad de las muestras tratadas, y se demostró que, en presencia de membrana, a mayor densidad de corriente y con el electrodo de BDD la toxicidad de la muestra es mayor debido a la mayor presencia en disolución de iones persulfato. Por tanto, con el electrodo cerámico, además de alcanzar un elevado grado de degradación del contamina / [CAT] La present Tesi Doctoral es centra en l'estudi del comportament electroquímic de nous elèctrodes ceràmics basats en SnO2 dopat amb Sb2O3. L'estudi està orientat a la posterior aplicació d'aquests elèctrodes en processos electroquímics d'oxidació avançada. Inicialment, es van considerar diferents temperatures de sinterització (entre 1050°C i 1250°C) i es va observar que un augment en la temperatura de sinterització afavoria la deposició de Sb2O3 en la superfície anòdica, disminuint així la resistivitat de l'elèctrode. Posteriorment, es va estudiar el comportament electroquímic d'aquests nous elèctrodes obtenint el potencial de descàrrega de l'oxigen mitjançant la tècnica de voltametria de passada lineal. Els resultats obtinguts van revelar que el valor del potencial de descàrrega de l'oxigen disminueix amb l'augment de la temperatura de sinterització. A més, aquests elèctrodes ceràmics van presentar un comportament intermedi entre l'ànode de Pt y l'ànode de BDD. Aquest últim elèctrode s'utilitza habitualment en els processos electroquímics d'oxidació avançada a causa de la seua elevada capacitat per a generar radicals hidroxil, els quals són capaços d'oxidar els compostos orgànics a diòxid de carboni i aigua. A continuació, es van dur a terme assajos d'oxidació electroquímica amb aquests elèctrodes ceràmics per a seleccionar la temperatura de sinterització. Els resultats van mostrar que amb l'elèctrode ceràmic sinteritzat a 1250°C s'aconsegueix una menor degradació del compost orgànic, mentre que els elèctrodes sinteritzats a menors temperatures presenten un comportament similar entre ells. Per tant, es va seleccionar l'elèctrode ceràmic sinteritzat a 1200 °C ja que presenta una baixa resistivitat i un bon comportament electroquímic per a ser utilitzat com a ànode en els processos electroquímics d'oxidació avançada. Seguidament, es va analitzar la vida útil d'aquests elèctrodes ceràmics, i es va comprovar que la matriu ceràmica incrementa en gran mesura l'estabilitat a la polarització anòdica dels elèctrodes basats en SnO2. Posteriorment es van dur a terme processos d'electro-oxidació en mode galvanostàtic de diferents contaminants difícils d'eliminar per les tècniques convencionals utilitzant com a ànode els nous elèctrodes ceràmics i l'elèctrode de BDD, per a així poder comparar els resultats obtinguts. Es va observar que, encara que amb els elèctrodes ceràmics s'aconsegueix degradar el 100% dels diferents contaminants, l'elèctrode de BDD és el més eficient ja que genera una major quantitat d'espècies oxidants actives en la seua superfície. Per a un mateix elèctrode, es va observar que un augment en la densitat de corrent aplicada millora la velocitat de degradació i mineralització de cada contaminant, mentre que l'eficiència elèctrica disminueix. D'altra banda, es va estudiar l'efecte de la presència d'una membrana d'intercanvi catiònic entre ànode i càtode. Els resultats van mostrar que l'ús de la membrana beneficia la degradació i la mineralització del contaminant, ja que millora la cinètica de reacció anòdica i evita la reducció de les espècies oxidants electrogenerades. A continuació, es va analitzar la influència de la concentració del Na2SO4 com a electròlit suport. En aquest estudi es va observar que un augment en la concentració del Na2SO4 millora la mineralització del contaminant per a l'elèctrode de BDD i, per contra, empitjora per a l'elèctrode ceràmic. Això es deu a la capacitat de cada elèctrode per a oxidar els sulfats a persulfats. Finalment, es van dur a terme assajos d'ecotoxicitat de les mostres tractades, i es va demostrar que, en presència de membrana, a major densitat de corrent i amb l'elèctrode de BDD la toxicitat de la mostra és major a causa de la major presència en dissolució d'ions persulfat. Per tant, amb l'elèctrode ceràmic, a més d'aconseguir un elevat grau de degradació del con / [EN] The present Doctoral Thesis focuses on the study of the electrochemical behaviour of new ceramic electrodes based on SnO2 doped with Sb2O3. The study is oriented at the subsequent application of these electrodes in electrochemical advanced oxidation processes. Initially, different sintering temperatures were considered (between 1050°C and 1250°C) and it was observed that an increase in the sintering temperature favoured the deposition of Sb2O3 on the anodic surface, thus decreasing the resistivity of the electrode. Later, the electrochemical behaviour of these new electrodes was studied by means of the oxygen discharge potential using the linear sweep voltammetry technique. The results obtained revealed that the value of the oxygen discharge potential decreases with increasing the sintering temperature. Furthermore, these electrodes showed an intermediate behaviour between the Pt anode and the BDD one. This last electrode is commonly used in advanced electrochemical oxidation processes due to its high capacity to generate hydroxyl radicals, which are capable of oxidizing the organic compounds to carbon dioxide and water. Then, electrochemical oxidation tests were carried out with these ceramic electrodes to select the sintering temperature. The results showed that with the ceramic electrode sintered at 1250°C, a lower degradation and mineralization of the organic compound is achieved, while the electrodes sintered at lower temperatures showed a similar behaviour. Therefore, the ceramic electrode sintered at 1200°C was selected as it presents low resistivity good electrochemical behaviour to be used as anode in electrochemical advanced oxidation processes. Next, the service life of these ceramic electrodes was analyzed, and it was found that the ceramic matrix greatly increases the anodic polarization stability of the electrodes based on SnO2. Subsequently, electro-oxidation processes were carried out in galvanostatic mode for different contaminants that are difficult to remove by conventional techniques, using the new ceramic electrodes and the BDD electrode as anodes, in order to compare the results obtained. It was observed that ceramic electrodes can be used as anodes for electrochemical oxidation, since for high current densities it is possible to degrade a 100% of the different contaminants. However, the BDD electrode is the most efficient one since it generates more active oxidant species on its surface. For a given electrode, an increase in the current density improves the degradation and mineralization of each contaminant, while the electrical efficiency decreases. On the other hand, the effect of the presence of a cation-exchange membrane between anode and cathode was studied. The results showed that its use benefits the degradation and mineralization of the contaminants, since it improves the kinetics of the anodic reaction and avoids the reduction of the electrogenated oxidant species. Next, the influence of the concentration of Na2SO4 as supporting electrolyte was analyzed. In this study it was observed that an increase in the Na2SO4 concentration improves the mineralization of the contaminant for the BDD electrode and, on the contrary, worsens for the ceramic electrode. This is due to the ability of each electrode to oxidize sulfates to persulfates. Finally, ecotoxicity tests on the treated samples were carried out, and it was shown that, in the presence of the membrane, at higher current density and with the BDD electrode, the toxicity of the sample is greater due to the higher presence of persulfate ions. Therefore, with the ceramic electrode, in addition to achieving a high degree of contaminant degradation, the treated samples are less toxic than the samples treated with the BDD electrode. / Agradezco al Ministerio de Economía y Competitividad por la financiación recibida mediante los proyectos CTQ2015-65202-C2-1-R y RTI2018-101341-B-C21, y a la cofinanciación con los fondos FEDER, que han permitido llevar a cabo la investigación en la Universitat Politècnica de València para la realización de la presente Tesis. También agradecer a Sergio Mestre Beltrán por proporcionarnos los nuevos electrodos cerámicos en los que se ha basado este trabajo. / Mora Gómez, J. (2020). Eliminación de contaminantes orgánicos emergentes mediante procesos electroquímicos de oxidación avanzada [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/158751 / TESIS
148

Dégradation du paracétamol et de la ciprofloxacine par des procédés d'oxydation avancés dans des eaux usées / Degradation of paracetamol and ciprofloxacin by advanced oxidation processes in wastewater.

González-Labrada, Katia 20 December 2018 (has links)
Ce travail étudie la faisabilité de différents procédés d’oxydation avancée (POAs) pour le traitement d’eaux usées industrielles. Le secteur visé est l’industrie pharmaceutique, les essais ont été menés sur des eaux synthétiques contenant deux molécules modèles: le paracétamol et la ciprofloxacine. Les procédés étudiés dans ce travail sont l’ozonation, la sonochimie, le traitement par radiation gamma et la dégradation par radiation ultraviolet. Ces techniques sont envisagées en mono-traitement ou en combinaison avec des oxydants et/ou des catalyseurs (peroxyde d’hydrogène, réactif de Fenton et zéolite Fe/MFI). Pour chaque procédé, l'influence de différents paramètres opératoires est analysée et interprétée dans l'objectif de déterminer les meilleures conditions pour la conversion et la minéralisation du chaque polluant. Parmi les paramètres étudiés se trouvent le pH, la concentration en oxydant, la concentration du catalyseur, la dose de la radiation gamma, la fréquence et la puissance ultrasonore. Des effets synergiques importants sont trouvés pour l’ozonation catalytique et pour le photo-Fenton par rapport aux procédés seuls. D’un point de vue purement énergétique, les traitements les plus efficaces sont l’oxydation radio- Fenton et l’oxydation photo-Fenton. Sur la base de ces résultats, un photo-réacteur solaire à recirculation est mis en oeuvre pour traiter par oxydation photo-Fenton des solutions synthétiques préparées avec un mélange de paracétamol et de ciprofloxacine dans l’eau du robinet mais aussi avec des eaux usées réelles dopées avec les deux composés. Dans les deux cas, la dégradation des molécules dépasse 95% dans les 15 premières minutes et la minéralisation dépasse 55% en 180 minutes. / In this work, the feasibility of paracetamol and ciprofloxacin degradation by different advanced oxidation processes (AOPs) was investigated. These molecules are representative of pharmaceutical pollutants found in wastewater. The used processes were the ozonation, the high frequency ultrasound, the gamma radiation and the ultraviolet radiation, alone or in combination with oxidizers and/or catalysts (hydrogen peroxide, Fenton’s reagent and zeolite Fe/MFI). The influence of different operations parameters (pH, oxidant concentration, catalyst concentration, gamma radiation dose and ultrasonic power and frequency) for each processes were studied, in order to determine the optimal operating ranges for the degradation and mineralization of the pharmaceuticals pollutants. Results showed marked synergistic effects by combining individual processes with hydrogen peroxide or Fenton’s reagent, being the most important synergy factors those corresponding to the heterogeneous catalytic ozonation and photo-Fenton processes. Taking into account the energy consumption, the mineralization and the synergy factor, the most effective treatments were radio-Fenton oxidation and photo-Fenton oxidation. Optimal conditions for photo-Fenton oxidation were studied in an open channel reactor at bench scale in tap water and in a real matrix from a municipal wastewater treatment plant. Samples were spiked with a mixture of the pharmaceuticals. In both cases 95% degradation within the first 15 minutes was achieved and its mineralization exceeded 55% in three hours.
149

The preparation and catalytic activity of iron oxide silica nanofibers for the Fenton degradation of methylene blue.

Mthombo, Phindile January 2020 (has links)
M.Tech. (Department of Chemistry, Faculty of Applied and Computer Sciences), Vaal University of Technology. / Several industries utilize species of synthetic dyes that are found in their wastewater, which is passed out in the environment. Methylene blue is one of the organic dyes that causes water pollution. It causes damage to the aquatic eco-system and health problems to human beings. It is non-biodegradable due to its chemical nature. Advanced oxidation processes (AOP’s) have been developed for the degradation of these dyes, however, some of these methods are limited due to their high cost and low efficiency. Among these methods, Fenton catalysis has been proven to be an effective method due to its low cost, high efficiency, and re-usability. Iron oxide nanoparticles have been mainly used in Fenton process however they are also limitated due to the forming of secondary pollutants, due to catalysts recovery difficulties, hence they require supporting materials. In this work, iron oxide-based catalyst supported on silica nanofibers were fabricated via electrospinning of silica sol incorporated with iron oxide, using three different routes, (a) Method 1 - wetness incipient impregnation, (b) Method 2 - direct addition of iron precursor to the silica sol and (c) Method 3 - incorporation of iron oxide nanoparticles into silica sol. The effect of iron oxide concentration loadings (1 wt%, 2 wt% and 5 wt %) was studied. Increase in iron content resulted in agglomeration of nanoparticles as embedded in the fibers as evident from their SEM images in method 3.1. The SEM results showed diameters from method 1, 2 and 3 ranging from the distribution ranges of 276 – 288 nm, 243 – 265 nm and 188 nm, respectively. EDS showed the presences of Si, P, Fe, O and P. XRD showed a crystalline phase of magnetite (9 nm) and goethite (32 nm) method 1 and 3, with vibrational modes at 3300 cm-1, 1100 cm-1, 950 cm-1 and 580 cm-1 ascribed to O-H, Si-O-Si, Si-O and Fe-O on the FTIR spectra, it showed both the presence of silica and iron oxide. The degradation of methylene blue was monitored by UV-Vis spectroscopy, the Fenton catalytic activity of the iron-oxide supported on silica nanofibers showed higher catalytic activity compared to the unsupported iron-oxide nanoparticles. The catalyst prepared by wetness incipient impregnation (method 1) had a degradation efficiency of 69.1%, the direct addition of iron precursor to the silica sol (method 2) had 75.2% and incorporation of iron oxide nanoparticles magnetite and goethite with the silica sol had 53.7% and 34.7%, respectively. The catalyst prepared by the direct addition of iron precursor in the sol (method 2) showed a high catalytic activity compared to the other catalyst prepared by other methods. Unsupported Iron oxide nanoparticles had a higher degree of leaching of 1.28 ppm magnetite, and 1.68 ppm goethite, compared to the supported iron oxide in method 1 and method 3. The catalyst incorporated with goethite showed a high degree of leaching, 3.95 ppm and 1.33 ppm. The catalyst with high catalytic activity showed a lower degree of leaching with 0.05 ppm.
150

Znovu-užití vyčištěných odpadních vod v papírenském a textilním průmyslu / Reuse of treated wastewater in paper and textile industry

Matysíková, Jana January 2012 (has links)
This thesis deals with Advanced oxidation processes (AOP) and its aplication for textile wastewaters treatment and reuse. AOP is a modern technology which currently recieves increased attention due to it´s high efficiency in removing resistant and hardly-degradable pollution. Thesis consists of search and practical part. Search part is created by three chapters. First chapter describe briefly wastewater reuse. The second chapter deals with Advanced oxidation processes. AOP principle, AOP division and descriotion is included with the strong focus on the ozonation technology. The third chapter presents the textile industry and its wastewaters. The practical part of this thesis consists of two chapters. Chapter 5 describes testing of textile wastewaters decoloration by ozonation in the selected textile copany and its results. This results are used in chapter 6. Chapter 6 is the study of textile industry treatment and reuse in the selected textile company. This study contains the design of two options for wastewater treatment and reuse in the textile processes.

Page generated in 0.1003 seconds