• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 10
  • 8
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 95
  • 95
  • 25
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Dispersionsoptimierung von Kohlenstoffnanoröhren für die Herstellung von Polymer-Komposit-Drucksensoren

Gerlach, Carina 27 November 2017 (has links)
Kohlenstoffnanoröhren (engl. carbon nanotubes, CNT)-Polymer-Komposite haben ein großes Potential im Bereich sensorischer Anwendungen. Dabei spielen die elektrischen Eigenschaften des Komposits und deren Änderungen unter mechanischer Belastung eine entscheidende Rolle. Einen maßgeblichen Einfluss nimmt dabei das Aspektverhältnis der CNT-Agglomerate sowie der CNTs selbst ein, welches jeweils vom CNT-Desagglomerationsprozess bestimmt wird. Die Dispergierung beeinflusst folglich auch die elektrische Leitfähigkeit und Reproduzierbarkeit des Komposits sowohl im mechanisch unbelasteten als auch belasteten Zustand. Dies wurde anhand von (teil-)analytischen Modellen gezeigt. Die Dispersionsqualität wird dabei von vielen Faktoren beeinflusst, wobei die Prozessparameter beim Ultraschalldispergieren derzeit nach der Trial-and-Error-Methode bestimmt werden. Im Rahmen der Arbeit wurde eine Dispergiergleichung für zylindrische Partikel, die CNTs näherungsweise sind, erstmals für die Dispergierung von CNTs in Lösungsmitteln entwickelt, angewendet sowie verifiziert. Die Gültigkeit der Gleichung für CNTs wurde durch Variation der Ultraschallparameter Zeit sowie Energie und deren Einfluss auf den Dispergiergrad gezeigt. Die mittels UV-VIS-Spektroskopie gemessene Extinktion diente dabei als indirekte Messgröße des Dispergiergrads. Nach Vorversuchen zur geeigneten Materialauswahl wurden alle relevanten Einflussparameter berechnet oder experimentell bestimmt. Die experimentelle Verifikation erfolgte an CNT-N-Methyl-2-pyrrolidon-Dispersionen, die mittels Ultraschallsonotrode kontrolliert dispergiert wurden. Im Ergebnis wurde gezeigt, dass die Bestimmung der optimalen Ultraschallparameter möglich ist und die bis dahin übliche Praxis der experimentellen Bestimmung der Dispergierparameter für CNTs ablösen kann. Mithin wurde die Grundlage für die Herstellung elektrisch reproduzierbarer CNT-Polymer-Komposit-basierter Sensoren gelegt. Darüber hinaus wurde das Anwendungspotential dieses Sensorkonzepts für Einzelsensoren zur punktuellen Druckmessung über eine Druckverteilungsmessung als Sensormatrix bis hin zur Anwendung als Einlegesohle im Schuh zur Überwachung des Drucks gezeigt. / Carbon nanotubes (CNT) polymer composites in the field of sensory applications have considerable potential. However, their electrical properties and their changes under mechanical stress play a decisive role. The deagglomeration process of the CNTs also has a great influence on the aspect ratio of the CNT agglomerates as well as the CNTs themselves and thus the electrical conductivity and reproducibility of the composite in both the mechanically unloaded and loaded state.This is shown by means of (partially) analytical models. The dispersion quality is influenced by many factors. The process parameters during ultrasound dispersion are currently being determined by a trial-and-error method. Within the scope of the work, a dispersing equation for cylindrical particles, which are approximate to CNTs, was first developed, applied and verified for the dispersion of CNTs in solvents. The validity of the equation for CNTs was shown by the variation of the ultrasonic parameters time as well as energy and their influence on the degree of dispersion. The absorbance measured by means of UV-VIS spectroscopy serves as an indirect measure of the degree of dispersion. After pre-testing for suitable material selection, all relevant influencing parameters were calculated or determined experimentally. Experimental verification was carried out on CNT-N-methyl-2-pyrrolidone dispersions, which were dispersed in a controlled manner by means of an ultrasonic sonotrode. As a result, it is illustrated that the determination of the optimal ultrasonic parameters is possible and can replace the conventional practice of the experimental determination of the dispersing parameters for CNTs. Accordingly, the basis for the production of electrically reproducible CNT polymer composite-based sensors has been established. In addition, the application potential of this sensor concept ranging from individual sensors for selective pressure measurement over pressure distribution measurement as a sensor matrix to the application as a shoe insole for pressure monitoring was shown.
92

Temperature-Compensated Force/Pressure Sensor Based on Multi-Walled Carbon Nanotube Epoxy Composites

Dinh, Nghia Trong, Kanoun, Olfa 10 November 2015 (has links)
In this study, we propose a multi-walled carbon nanotube epoxy composite sensor for force and pressure sensing in the range of 50 N–2 kN. A manufacturing procedure, including material preparation and deposition techniques, is proposed. The electrode dimensions and the layer thickness were optimized by the finite element method. Temperature compensation is realized by four nanocomposites elements, where only two elements are exposed to the measurand. In order to investigate the influence of the filler contents, samples with different compositions were prepared and investigated. Additionally, the specimens are characterized by cyclical and stepped force/pressure loads or at defined temperatures. The results show that the choice of the filler content should meet a compromise between sensitivity, temperature influence and noise behavior. At constant temperature, a force of at least 50N can be resolved. The measurement error due to the temperature influence is 150N in a temperature range of –20°C–50°C.
93

Digitalisera tryckmätning över filter hos AstraZeneca / Digitalization of pressure measurement over filters at AstraZeneca

Hosseiny, Heshmat, Köpsén, Emil January 2023 (has links)
AstraZeneca är ett medicinskt företag lokaliserat i Södertälje som har cirka 900 luftfilterboxar hos sin anläggning i Gärtuna. Dessa filterboxar kan vara opraktiska att hålla koll på eftersom de är utspridda uppe på vindarna, samt att det behövs bra framförhållning vid filterbyten eftersom vissa filter innehåller farliga ämnen. Filterboxar är utrustade med analoga tryckmätare vilket innebär att det kan bli omständigt för personalen att övervaka filtrets tryckfall. Målet med det här examensarbetet är att hitta en digital lösning som underlättar övervakningen av tryckfall över filter i realtid, samt informerar via sms eller mejl när det är dags att planera in filterbyte. Visionen är att det ska bli enklare att få en bild över luftfiltrets underhållsmässiga skick. Genom att jämföra olika produkter och delta i regelbundna möten med IT kunnig personal valdes en lämplig produkt. Projektet har arbetat metodiskt och strukturerat genom att följa projektmodellen projekt case där verktygen GANTT-schema, SWOT-analys, FMEA och maxiriskmetoden har använts. Projektet resulterade i användningen av digitala differentialtryckgivare som mäter tryckfallet över filter. Differentialtryckgivaren samlar data som sedan skickas via radiofrekvens till en Ethernet gateway som är trådad in till AstraZenecas segregerade nätverk så kallat FAB-net. Därefter förs datan från ethernet gatewayen till mjukvara. I mjukvaran kommer AstraZenecas filtergrupp kunna se över tryckfall hos de olika filtrena i filterboxarna. Detta kommer underlätta personalens arbete och eventuellt spara AstraZeneca tid och pengar. / AstraZeneca is a medical company located in Södertälje that has around 900 air filter boxes at its facility in Gärtuna. These filter boxes can be impractical to keep track of as they are scattered up in the attics and good foresight is needed for multiple filter changes as some filters contain harmful substances. Filter boxes are equipped with analog pressure gauges, which means that there is a lot of walking for the staff in order to monitor the filter's pressure drop. The goal of this thesis is to find a digital solution that can facilitate the monitoring of pressure drops across filters in real time and that also informs by text message or email when it is time to schedule a filter change. The vision is that it will be easier to get a digital image of the maintenance condition of the air filter. By comparing different products and participating in regular meetings with AstraZeneca's IT personnel, a suitable product was chosen. The project has worked methodically and structured by following the project model project case where tools such as GANTT chart, SWOT analysis, FMEA and maxirisk method have been used. The project resulted in the use of digital differential pressure sensors that measure the pressure drop across filters. The differential pressure sensor collects data which is then sent by radio frequency to an ethernet gateway which is wired into AstraZeneca's segregated network called FAB-net. The data is then transferred from the ethernet gateway to the software. AstraZeneca's filter group will be able to review the pressure drop of the various filters within the software, which will facilitate their way of working and potentially save AstraZeneca time and money.
94

Monitorovací systém vodních toků s GSM komunikací / River mionitoring system with GSM communication

Pačinek, David January 2014 (has links)
This master thesis is dedicated to system of water monitoring for use of alternative source power supply and GSM communication. The thesis carried out research on the possibilities to take measurements on watercourses, also detailed research of photovoltaic panel, available accumulators and their charging and a synopsis of similar systems. Furthermore, the master thesis also captures design and implementation datalogger device type with possibility to send measured data to the website.
95

Direkter Drucksensor unter Verwendung von Kohlenstoffnanoröhren-Nanokompositen

Dinh, Nghia Trong 28 April 2016 (has links)
Im Gegensatz zu herkömmlichen Dehnungsmessstreifen können Carbon nanotube (CNT)-basierte Komposite zusätzlich eine ausgeprägte Druck-abhängigkeit des Widerstandes aufweisen. Deshalb können Drucksensoren aus CNT-Nanokomposite ohne den Einsatz von Verformungskörpern wie z. B. Biegebalken aufgebaut werden. Die möglichen Anwendungsgebiete für diese direkt messenden Sensoren wurden in der vorliegenden Arbeit bei drei industriellen Anwendungen wie z. B. bei Robotergreifarmen gezeigt. Die Zielstellung dieser Arbeit ist die Entwicklung und Charakterisierung eines neuartigen Sensors aus CNT-Nanokomposite. Unter Verwendung von Multi-walled carbon nanotube (MWCNT)-Epoxidharz und interdigitalen Elektroden soll der Sensor auf wenigen Quadratzentimetern Drücke im Megapascal-Bereich und somit Kräfte im Kilonewton-Bereich messen können. Durch die Auswahl geeigneter Werkstoffe und die Modellierung mit der Finite Element Methode wurde der Sensorentwurf durchgeführt sowie der Messbereich abgeschätzt. Die Herstellung der MWCNT-Epoxidharz-Dispersion erfolgte durch mechanische Mischverfahren. Anschließend wurden aus der Dispersion druckempfindliche Schichten mit der Schablonendrucktechnik hergestellt. Dabei wurden die Herstellungs-parameter und besonders der Füllstoffgehalt der MWCNTs variiert, um deren Einflüsse auf das mechanische, thermische und elektrische Verhalten zu untersuchen. Die Charakterisierung der mechanischen Kenngrößen erfolgte mit Zugversuchen und dynamisch-mechanischer Analyse. In den Untersuchungen zeigen die MWCNT-Komposite eine signifikante Steigerung der Zugfestigkeit und eine Erhöhung der Glasübergangstemperatur gegenüber reinem Epoxidharz. Die Abhängigkeiten der Druckempfindlichkeit und der Temperaturempfindlichkeit vom Füllstoffgehalt wurden untersucht. Eine besonders hohe Druckempfindlichkeit, aber auch Temperaturempfind-lichkeit wurde bei Proben mit geringem Füllstoffgehalt (1 wt% und 1,25 wt%) festgestellt. Es ist also wichtig, die richtige Materialkombination für diese Art Sensor zu finden. Die realisierten Sensoren liefern zuverlässige Antwortsignale bei wiederholten Belastungen bis zu einer Belastung von 20 MPa (entspricht 2 kN). Zusätzlich wurde der Temperatureinfluss in einem Bereich von −20 °C bis 50 °C durch eine Wheatstonesche Brückenschaltung kompensiert. Die vorliegende Arbeit zeigt, dass eine zuverlässige Druckmessung mit einer Temperaturmessabweichung von 0,214 MPa/10 K gewährleistet werden kann. / In contrast to conventional metallic strain gauges, carbon nanotube (CNT) composites have an additional pressure sensitivity. Therefore, deformation elements such as bending beam is not needed by using pressure sensors, which are based on CNT nanocomposite. The possible areas of application for these pressure direct measured sensors were showed in three industrial application such as robot gripper. The focus of this work is the development and characterization of a new sensor manufactured from CNT nanocomposite. By using multi-walled carbon nanotube (MWCNT) epoxy and interdigital electrodes the sensor, which has a dimension of few square centimetre, should measure a pressure in mega Pascal range and hence a force in kilo newton range. By the selection of suitable materials and the modelling using finite element method, the sensor design as well as the measurement range were carried out. The MWCNT epoxy dispersion is manufactured by using a mechanical mixing process. Subsequent, the dispersion is used to fabricate pressure sensitive layers by stencil printing methods. Thereby, the fabrication parameters and especially the filler content of the MWCNTs were varied for the mechanical, thermal and electrical investigation. The characterization of the mechanical characteristic values were carried out by using tensile test and dynamic mechanical analysis. The results show a significant increasing of the tensile strength and glass transition temperature in comparison to neat epoxy. Additionally, the influence of the filler content to the pressure and thermal sensitivity were investigated. A highly pressure sensitivity but also a highly thermal sensitivity are obtained for samples with lower filler contents (1 wt% and 1.25 wt%). Therefore, a suitable material combination has to be chosen. The fabricated sensors show reliable response signals by repeated excitations up to 20 MPa (meets to 2 KN). Moreover, the temperature influence ranged from -20 °C to 50 °C was compensated with a Wheatstone bridge. This work demonstrate a direct pressure sensitive sensor with reliable response signals by a thermal deviation of 0.214 MPa/10K.

Page generated in 0.0301 seconds