Spelling suggestions: "subject:"photo fenton"" "subject:"thoto fenton""
81 |
Desenvolvimento de um tratamento contínuo de efluente têxtil utilizando filtros de cigarros modificados com íons férricosGalvão, Davi Simão 27 February 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-06-25T17:48:09Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Davi Simao Galvao.pdf: 1029030 bytes, checksum: 99c884860ac3a4a739e68c8582f89c21 (MD5) / Made available in DSpace on 2018-06-25T17:48:09Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Davi Simao Galvao.pdf: 1029030 bytes, checksum: 99c884860ac3a4a739e68c8582f89c21 (MD5)
Previous issue date: 2018-02-27 / Com o aumento da população nas últimas décadas, consequentemente aumenta o número de indústrias para suprir as necessidades básicas da população. Dentre essas empresas, a indústria que ganha destaque na região do Paraná é o setor têxtil, onde ocupa o 2º maior pólo confeccionista do Brasil. O grande problema desse setor é que durante o beneficiamento dos tecidos 10-15% dos corantes são lixiviados ao meio ambiente, acarretando sérios danos ao próprio meio ambiente. Desta forma, buscam-se métodos mais eficientes para degradação desta matéria orgânica poluidora, dentre os métodos alternativos que têm sido estudados o Processo Avançado Oxidativo (PAO) é baseado na geração do radical hidroxila (HO•), que é um forte agente oxidante levando a oxidação da matéria orgânica. Esse processo ainda pode ser dividido em vários tipos, como processos com e sem radiação, homogêneos e heterogêneos. Assim o objetivo deste trabalho foi estudar a degradação de um efluente têxtil real utilizando o processo “tipo-Fenton”, onde utiliza-se os filtros de cigarros como material suporte para a imobilização de íons férricos. Para monitorar a degradação foi utilizado técnicas analíticas como Carbono Orgânico Total (COT), Demanda Química de Oxigênio (DQO),Turbidez, Cor, detecção de Ferro Total, e a detecção de peróxido de hidrogênio. Os resultados mostraram que no reator contínuo o COT foi reduzido em 78,62%, a DQO em 64%, a turbidez 65,5%, enquanto que a cor 42% em 90 minutos de reação. A lixiviação de ferro total foi de 0, 072 mg L-1 e o peróxido residual foi 29 mg L-1. Isso mostra a eficiência desse método para tratamento de efluentes têxteis. / With the increase of the population in the last decades, consequently the number of industries increases to satisfy the basic necessities of the population. Among these companies, the industry that stands out in the region of Paraná is the textile sector, where it occupies the second largest confectionary pole in Brazil. The biggest problem of this sector is that during the processing of the tissues 10-15% of the dyes are leached to the environment, causing serious damages to the own environment. The Oxidative Advanced Process (PAO) is based on the generation of the hydroxyl radical (HO•), which is a strong oxidizing agent leading to the oxidation of organic problem. This process can still be divided into several types, such as homogeneous and heterogeneous processes with and without radiation. Thus the objective of this work was to study the degradation of a real textile effluent using the "Fenton-like" process, where the cigarette filters are used as support material for the immobilization of ferric ions. To monitor the degradation, analytical techniques such as Total Organic Carbon (TOC), Chemical Oxygen Demand (COD), Turbidity, Color, Total Iron Detection and the detection of hydrogen peroxide.The results showed that in the continuous reactor the TOC was reduced by 78.62%, the COD by 64%, the turbidity 65.5%, while the color 42% by 90 minutes of reaction. Total iron leaching was 0.072 mg L-1 and the residual peroxide was 29 mg L-1. This shows us the efficiency of this method for treatment of textile effluents.
|
82 |
Processos de tratamento não convencionais para degradação do antibiótico sulfadiazina em meio aquoso. / Non-conventional treatment processes for the degradation of the antibiotic sulfadiazine in aqueous medium.Acosta, Arlen Mabel Lastre 25 April 2016 (has links)
A presença de antibióticos no meio ambiente aquático tem causado crescente preocupação mundial. Além dos relatos de resistência de bactérias a antibióticos, essa classe de fármacos também pode causar efeitos tóxicos e atuar como perturbadores endócrinos em diversos organismos vivos e, possivelmente, em humanos. Dentre os antibióticos comumente usados destacam-se as sulfonamidas, detectadas em águas subterrâneas e superficiais. Os processos avançados de oxidação (POA) têm sido apontados como tecnologias eficientes para tratamento de poluentes recalcitrantes em diferentes matrizes aquosas. Dentre os POA, o processo foto-Fenton é uma alternativa para a degradação de compostos não biodegradáveis, incluindo fármacos. Uma vez que a principal limitação do processo é o intervalo de pH (2,5- 4,0), a reação pode ser vantajosamente conduzida empregando-se substâncias bio-orgânicas solúveis (BOS) como agentes complexantes de Fe3+ em condições ligeiramente ácidas (pH 5). Por sua vez, o emprego da energia ultrassônica tem sido menos estudado. Nesse contexto, o objetivo deste trabalho é estudar a degradação do antibiótico sulfadiazina (SDZ) por meio do processo foto-Fenton na presença de substâncias bio-orgânicas solúveis (UVvis/ Fe3+/H2O2/BOS) e do processo de cavitação por meio de ultrassom (US). Os resultados obtidos mostram que a sulfadiazina é eficientemente degradada por ultrassom de alta frequência. As maiores porcentagens e taxas de remoção são obtidas usando menor frequência de operação (580 kHz), maior potência dissipada e em pH ligeiramente ácido (melhor condição: pH 5,5). Além disso, a reação de Fenton, combinada com o tratamento US, melhorou notavelmente a degradação da SDZ, particularmente quando quantidades extras de H2O2 foram adicionadas ao sistema. Por sua vez, o uso de BOS como aditivos no processo foto-Fenton apresenta influência marcante na fotodegradação da SDZ em condições ligeiramente ácidas (pH 5). Os BOS podem estabilizar espécies de ferro em solução aquosa em pH próximos ao neutro, o que constitui uma propriedade de grande interesse. Sob as condições estudadas, o BOS CVT230 foi mais eficiente do que FORSUD, provavelmente devido às diferenças nos grupos funcionais presentes na composição destas substâncias. Finalmente, foram calculados os indicadores de consumo de energia elétrica por ordem de grandeza (EEO) para o processo de ultrassom (1572 kW h m-3 ordem-1) e área do coletor por ordem de grandeza (ACO) para o processo foto-Fenton (8,07 m2 m-3 ordem-1). / The potential impacts of antibiotic residues in the environment have become an emerging concern during recent years due to their relation with the development of resistant bacteria, and in some cases to their ability to cause toxic and endocrine disrupting effects in humans and other living organisms. Highlighted among the commonly used antibiotics are the sulfonamides, detected in groundwater and surface water. Advanced oxidation processes (AOP) might constitute an important alternative to deal with pharmaceuticals degradation. Among them, the photo-Fenton process has been widely used. One of its major drawbacks is the highly acidic pH needed (2,5-4,0) to avoid the formation of photochemically inactive iron oxides and hydroxides. The ability of soluble bio-organic substances (SBO) to complex metal cations such as iron is useful for the development of photo-Fenton at mild acidic conditions (pH 5). In turn, the use of ultrasonic energy has been less studied. In this context, the aim of this work is to study the degradation of the antibiotic sulfadiazine (SDZ) by the photo-Fenton process in the presence of soluble bio-organic substances (UV-vis/Fe3+/H2O2/SBO) and by ultrasonic cavitation (US). The results confirm that SDZ is effectively degraded by highfrequency ultrasound. Higher SDZ percent removals and removal rates were observed for the lowest operating frequency (580 kHz), higher dissipated power, and in slightly acidic solution (pH 5.5). On the other hand, SDZ degradation is highly improved in the case of the US/ Fe(II)/H2O2 system. The use of the SBO as Fenton additives in turn has a remarkable influence in SDZ photodegradation at slightly acid conditions (pH 5). This could be ascertained to the complexation of iron by the SBO, hence maintained in the reaction medium as a photoactive species. Under the studied conditions, the BOS CVT230 was more efficient than FORSUD, probably due to differences in the functional groups present in the composition of these substances. Finally, the figures-of merit electrical energy per order (EEO) and collector area per order (ACO) were calculated for the ultrasound (1572 kW h m-3 ordem-1) and photo-Fenton (8,07 m2 m-3 ordem-1) processes respectively.
|
83 |
Desenvolvimento de um reator fotoqu?mico aplic?vel no tratamento de efluentes fen?licos presentes na ind?stria do petr?leo / Development of a photochemistry reactor applicable in the treatment of phenolic wastewaters present in the petroleum industryMota, Andr? Lu?s Novais 02 December 2005 (has links)
Made available in DSpace on 2014-12-17T15:01:16Z (GMT). No. of bitstreams: 1
AndreLNM.pdf: 781178 bytes, checksum: d7b742a561481a98abbefe98cb97f8fb (MD5)
Previous issue date: 2005-12-02 / With water pollution increment at the last years, so many progresses in researches about treatment of contaminated waters have been developed. In wastewaters containing highly toxic organic compounds, which the biological treatment cannot be applied, the Advanced Oxidation Processes (AOP) is an alternative for degradation of nonbiodegradable and toxic organic substances, because theses processes are generation of hydroxyl radical based on, a highly reactivate substance, with ability to degradate practically all classes of organic compounds. In general, the AOP request use of special ultraviolet (UV) lamps into the reactors. These lamps present a high electric power demand, consisting one of the largest problems for the application of these processes in industrial scale. This work involves the development of a new photochemistry reactor composed of 12 low cost black light fluorescent lamps (SYLVANIA, black light, 40 W) as UV radiation source. The studied process was the photo-Fenton system, a combination of ferrous ions, hydrogen peroxide, and UV radiation, it has been employed for the degradation of a synthetic wastewater containing phenol as pollutant model, one of the main pollutants in the petroleum industry. Preliminary experiments were carrier on to estimate operational conditions of the reactor, besides the effects of the intensity of radiation source and lamp distribution into the reactor. Samples were collected during the experiments and analyzed for determining to dissolved organic carbon (DOC) content, using a TOC analyzer Shimadzu 5000A. The High Performance Liquid Chromatography (HPLC) was also used for identification of the cathecol and hydroquinone formed during the degradation process of the phenol. The actinometry indicated 9,06⋅1018 foton⋅s-1 of photons flow, for 12 actived lamps. A factorial experimental design was elaborated which it was possible to evaluate the influence of the reactants concentration (Fe2+ and H2O2) and to determine the most favorable experimental conditions ([Fe2+] = 1,6 mM and [H2O2] = 150,5 mM). It was verified the increase of ferrous ions concentration is favorable to process until reaching a limit when the increase of ferrous ions presents a negative effect. The H2O2 exhibited a positive effect, however, in high concentrations, reaching a maximum ratio degradation. The mathematical modeling of the process was accomplished using the artificial neural network technique / Com o crescente aumento da polui??o das ?guas acorrido nos ?ltimos anos, houve tamb?m um grande avan?o das pesquisas relacionadas ao tratamento de ?guas contaminadas. Efluentes contendo compostos org?nicos de alta toxicidade, nos quais o tratamento biol?gico n?o pode ser aplicado, os chamados processos oxidativos avan?ados (POA) surgem como uma alternativa para a degrada??o de subst?ncias org?nicas t?xicas n?o biodegrad?veis, pois estes processos s?o baseados na gera??o de radicais hidroxila, subst?ncias altamente reativas, capazes de degradar praticamente todas as classes de compostos org?nicos. Os POA, por muitas vezes, requerem o uso de reatores com l?mpadas especiais que emitem luz ultravioleta. Estas l?mpadas apresentam uma alta demanda de energia el?trica, consistindo, portanto, em um dos maiores problemas para a aplica??o desses processos em escala industrial. Este trabalho envolveu o desenvolvimento de um novo reator fotoqu?mico composto de 12 l?mpadas fluorescentes de luz negra de baixo custo como fonte de radia??o UV. O processo estudado foi o sistema foto-Fenton, uma combina??o de ?ons ferrosos, per?xido de hidrog?nio e radia??o ultravioleta, sendo aplicado na degrada??o de um efluente sint?tico aquoso contendo fenol, um dos principais poluentes da ind?stria do petr?leo. Foram realizados experimentos preliminares visando avaliar as condi??es operacionais do reator, al?m dos efeitos da intensidade da fonte de radia??o e distribui??o das l?mpadas no reator. As amostras foram analisadas quanto ao teor de carbono org?nico dissolvido (COD) utilizando um TOC 5000A da Shimadzu. A partir do recurso da cromatografia l?quida de alto desempenho (HPLC), p?de ser identificado a forma??o do catecol e da hidroquinona durante o processo de degrada??o do fenol. Pelo emprego da actinometria foi obtida uma taxa de incid?ncia de f?tons de 9,06⋅1018 foton⋅s-1, para 12 l?mpadas acionadas. Foi elaborado um planejamento fatorial ampliado do qual foi poss?vel avaliar a influ?ncia da concentra??o dos reagentes (Fe2+ e H2O2), al?m de ter sido determinado as condi??es ?timas experimentais ([Fe2+] = 1,6 mM e [H2O2] = 150,5 mM), obtendo um percentual m?ximo de degrada??o de 81,38 % em 1 hora de rea??o. Foi verificado que o aumento da concentra??o dos ?ons ferrosos ? favor?vel ao processo at? atingir um limite, quando o acr?scimo de ?ons ferrosos come?ou a apresentar um efeito negativo. O H2O2 apresentou um efeito positivo ao processo, atingindo um percentual m?ximo de degrada??o. A modelagem matem?tica do processo foi realizada utilizando o recurso da rede neural artificial, a qual p?de representar o sistema e o comportamento das vari?veis do processo
|
84 |
Estudo da tratabilidade do lixiviado de aterro sanitário pelos processos oxidativos avançados foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio / Study of treatability of landfill leachate by advanced oxidation processes photo-Fenton, ozone and ozone combined with hydrogen peroxideLuciano do Valle Monteiro 05 June 2012 (has links)
O lixiviado de aterro sanitário possui constituição complexa e é altamente poluente. Neste contexto, os processos oxidativos avançados se destacam como pré-tratamento, objetivando a remoção ou diminuição da recalcitrância do lixiviado. Neste trabalho foram utilizados os Processos Oxidativos Avançados (POAs) foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio. Avaliou-se a influência do pré-tratamento por air-stripping, a variação na produção de ozônio em 80 e 100%, a melhor dose de peróxido de hidrogênio correspondente a 20, 40 e 80% da dose de 6g O3/L empregada nos tratamentos com ozônio, a remoção de matéria orgânica, nitrogênio amoniacal total (NAT), alcalinidade, sólidos dissolvidos totais (SDT) (cloretos), produção de nitrito e nitrato, melhor razão molar [H2O2]/[Fe2+] para o tempo de contato de 80 min no foto-Fenton, uso do número médio de oxidação do carbono (NMOC) e a quantificação do ácido oxálico formado após a aplicação dos POAs. O tratamento por O3/H2O2 (1,2 g H2O2/L e produção de O3 em 80%) obteve a maior remoção de matéria orgânica, 0,14 g massa removida de Carbono Orgânico Total (COT) / massa consumida de O3 e 0,43 g/g para a Demanda Química de Oxigênio (DQO). Quanto ao foto-Fenton, averiguou-se o máximo de 74% remoção de COT e 65% remoção DQO para a razão molar [H2O2]/[Fe2+] igual a 2. Também se notou formação de sólidos sedimentáveis neste processo aplicado ao lixiviado bruto. O pré-tratamento por air-stripping não promoveu incremento na remoção de matéria orgânica. As concentrações de NAT, alcalinidade, SDT (cloretos) se mantiveram elevadas após a aplicação dos POA. Ocorreu formação de nitrato em todos os tratamentos. O uso do NMOC foi adequado e demonstrou ocorrência de oxidação nos processos. A quantificação do ácido oxálico formado após a aplicação dos POAs não foi apropriada nesta pesquisa. / The landfill leachate is a major waste produced by the landfill and its constitution complex and highly polluting motivate research in order to adapt their disposal on the environment. In this context, the advanced oxidation processes stand out as a pretreatment, in order to remove or decrease the recalcitrance of the leachate. In this work we used the photo-Fenton AOPs, ozone and ozone combined with hydrogen peroxide. We evaluated the effect of pretreatment for air-stripping, the variation in the production of ozone 80 and 100%, the best dose of hydrogen peroxide equal to 20, 40 and 80% of the dose of 6g O3/ L used in the treatments with ozone, the removal of organic matter, total ammonia nitrogen, alkalinity, dissolved solids (chlorides), production of nitrite and nitrate, best molar ratio [H2O2]/[Fe2+] to the contact time of 80 min in the photo-Fenton, average number of carbon oxidation use and the measurement of oxalic acid formed after application of the AOPs. The AOP O3/H2O2 (1.2g H2O2/L and O3 production by 80%) had the highest removal of organic matter, 0.14 g of TOC removed mass/ mass consumed O3 and 0.43 g/g for COD. As for the photo-Fenton, it was found a maximum of 74% removal of TOC and 65% for COD removal molar ratio [H2O2]/[Fe2+] equal to 2. It was also noted the formation of settle able solids in the process applied to the raw leachate. Pretreatment by air-stripping did not promote an increase in organic matter removal. Total ammonia nitrogen concentrations, alkalinity, dissolved solids (chlorides) remained high after application of the AOP, indicating possible oxidant demand. For nitrate formation occurred in all treatments, while only the photo-Fenton was no formation of nitrite. The use of average number of carbon oxidation was adequate and showed occurrence of oxidation processes. The quantification of oxalic acid formed after the application of AOPs was not appropriate in this research.
|
85 |
Espécies nitrogenadas em água de chuva de Ribeirão Preto (SP) / Nitrogen species in rainwater of Ribeirão Preto (SP)Cristina Penna Crispim 28 June 2018 (has links)
Espécies nitrogenadas vem sendo adicionadas ao meio ambiente de forma intensa desde o desenvolvimento do processo Haber-Bosch para transformação de N2 em NH3, alterando significativamente o ciclo biogeoquímico do nitrogênio no ambiente. Uma vez na atmosfera, o nitrogênio reativo é depositado de volta à superfície da Terra por processos de deposição úmida e seca. A importância de levar em conta as formas orgânicas de nitrogênio para estimar a deposição de nitrogênio atmosférico pela chuva (úmida) já é conhecida, no entanto, ainda há poucos trabalhos que avaliam essa fração devido às dificuldades e incertezas impostas pelos métodos analíticos disponíveis. Este trabalho traz o desenvolvimento de um novo método, simples e de baixo custo, para a determinação de nitrogênio orgânico (N-org) em água de chuva utilizando o processo foto-Fenton e um foto-reator construído de forma artesanal. Por meio da adição de solução de Fenton (50 µmol L-1 Fe2+ e 2 mmol L-1 H2O2) e 90 min de radiação UV (85 °C) foi possível obter em média 106 ± 8% de recuperação de nitrogênio para soluções contendo 50 µmol N L-1 das moléculas modelos: ureia, serina, glicina e histidina. No caso da arginina, 90 min de radiação foi suficiente para degradar soluções contendo 10 µmol N L-1. O reator comercial se mostrou mais eficiente na degradação dos compostos testados (30 min), no entanto, com um tempo de 75 min, o reator artesanal atingiu os mesmos resultados. Com o uso de 0,2 g L-1 TiO2 e 120 min de radiação UV, também foi possível obter resultados satisfatórios. Porém, esse método possuiu valores de branco elevados, havendo necessidade de filtrar as amostras irradiadas antes da análise, adicionando tempo e custo ao procedimento analítico. O método desenvolvido utilizando foto-Fenton foi aplicado para a determinação de N-org em amostras de água de chuva coletadas na cidade de Ribeirão Preto (SP) de 2013 a 2017. A concentração de N-org variou de 3,5 a 195 µmol N L-1 com concentração média ponderada pelo volume (MPV) de 17,7 ± 1,0 µmol N L-1 (n=236). Essa média foi maior que aquelas obtidas em água de chuva de várias partes do mundo, podendo ser atribuída a elevada queima de biomassa na região de estudo. As concentrações de aminoácidos livres dissolvidos (AA) representaram em média 15 ± 12% (n=144) em relação à fração orgânica de nitrogênio na chuva, enquanto as concentrações de ureia foram próximas ou inferiores ao limite de quantificação do método (0,5 µmol N L-1). Considerando toda série temporal iniciada no mesmo sítio amostral desde 2005, as concentrações MPV calculadas para os íons NH4+ foi de 22,2 ± 1,1 µmol L-1 (n=460), NO3- de 13,3 ± 0,6 µmol L-1 (n=466), sendo que a concentração de NO2- foi irrelevante. Foram obtidas concentrações significativamente mais elevadas (teste-t, P=0,05) de NH4+, NO3-, N-org e AA no período de safra da cana (seco) com relação à entressafra (chuvoso), para todos os anos avaliados. Apesar da colheita manual da cana ter sido drasticamente reduzida, o fato de manter a mesma tendência sazonal desde 2005, demonstra que a prática da queima de biomassa ainda é intensa na região. O uso de fogo para manejo na área rural ainda é comum, além de haver grandes áreas queimadas de forma acidental. A deposição úmida de nitrogênio (N-org + NH4+ + NO3-) para Ribeirão Preto foi de 10,5 kg (N) ha-1 ano-1, sendo que a fração orgânica representou 33% dessa deposição, demonstrando a importância de se determinar N-org para melhor estimar os fluxos atmosféricos de deposição. A massa estimada de nitrogênio depositada pela chuva é cerca de 16% do nitrogênio aplicado por meio de fertilizantes em culturas de cana. Somando as deposições de nitrogênio pelo material particulado, pela fase gasosa, e úmida, esta última representa 71% do fluxo atmosférico de nitrogênio. Nesse contexto, a fração orgânica corresponde a 24% da deposição total, sendo que este valor ainda pode estar sendo subestimado, pois as concentrações de N-org no material particulado não foram determinadas. A simplicidade e exatidão do método aqui proposto pode facilitar a aquisição de dados de N-org na chuva de outras partes do mundo, melhorando assim o conhecimento sobre o ciclo biogeoquímico global do nitrogênio. / Nitrogen species have been intensively added to the environment since the development of Haber-Bosch process for N2 transformation to NH3, significantly altering the biogeochemical cycle of nitrogen. Once in the atmosphere, reactive nitrogen is deposited back to the Earth\'s surface by wet and dry deposition processes. The importance of taking into account the organic forms of nitrogen to estimate atmospheric nitrogen deposition by rain is already known. However, few studies evaluated this fraction due to the difficulties and uncertainties imposed by the available analytical methods. This work presents the development of a new, simple and low-cost method for the determination of organic nitrogen (N-org) in rainwater using photo-Fenton process and a homemade photo-reactor. By adding Fenton solution (50 mol L-1 Fe2+ and 2 mmol L-1 H2O2) and keeping the reaction under UV radiation for 90 min (85 °C), it was possible to obtain an average of 106 ± 8% nitrogen recovery for solutions containing 50 mol N L-1 of the model molecules: urea, serine, glycine and histidine. In the case of arginine, 90 min of radiation was sufficient to degrade solutions containing 10 mol N L-1. A commercial reactor showed to be more efficient in degradation of the tested compounds (30 min). However, with a time of 75 min, the homemade reactor achieved the same results. With 0.2 g L-1 TiO2 and 120 min of UV radiation, it was also possible to obtain satisfactory results. Nevertheless, this method had high blank values, and filtration of irradiated samples before the analysis was necessary, which increased time and cost to the analytical procedure. The developed method using photo-Fenton was applied to determine N-org in rainwater samples collected in Ribeirão Preto city (SP) from 2013 to 2017. N-org concentrations ranged from 3.5 to 195 mol N L-1 with a volume-weighted mean concentration (VWM) of 17.7 ± 1.0 mol N L-1 (n = 236). This value was higher than those reported for rainwater from different parts of the world, and this fact can be attributed to the high biomass burning in the study region. Dissolved free amino acids (AA) mean concentrations represented 15 ± 12% (n = 144) of the organic nitrogen fraction in rain, while urea concentrations were close to or below the limit of quantification of the method (0.5 mol N L-1). Considering all temporal series, initiated in 2005 at the same sampling site, the VWM concentration calculated for NH4+ ions was 22.2 ± 1.1 mol L-1 (n = 460) and for NO3- was 13.3 ± 0.6 mol L-1 (n = 466), while NO2- mean concentration was irrelevant. Significantly higher concentrations (t-test, P = 0.05) of NH4+, NO3-, N-org and AA were obtained during the harvest period (dry season) in relation to the non-harvest one (rainy season), for all evaluated years. Although manual harvesting was drastically reduced, the fact that the same seasonal trend has been maintained since 2005 demonstrates that the practice of biomass burning is still intense in the region. In rural area, using fire for land management is still common, in addition to large areas burned by unintentional fires. Nitrogen deposition (N-org + NH4+ + NO3-) in Ribeirão Preto was 10.5 kg (N) ha-1 year-1, and the organic fraction represented 33% of this deposition, demonstrating the importance of determining N-org to better estimate the atmospheric deposition fluxes. The estimated mass of nitrogen deposited by rain represents approximately 16% of the nitrogen introduced by fertilizers in sugarcane crops. Summing up the nitrogen deposition by particulate matter, by gas phase, and by rain, the latter represents 71% of the atmospheric nitrogen flux. In this context, the organic fraction corresponds to 24% of the total deposition, and this value may still be underestimated, since N-org concentrations in particulate matter were not determined. The simplicity and accuracy of the method proposed here may facilitate acquisition of N-org data in rainwater from other parts of the world, thus improving the knowledge on the global biogeochemical cycle of nitrogen.
|
86 |
Processos de tratamento não convencionais para degradação do antibiótico sulfadiazina em meio aquoso. / Non-conventional treatment processes for the degradation of the antibiotic sulfadiazine in aqueous medium.Arlen Mabel Lastre Acosta 25 April 2016 (has links)
A presença de antibióticos no meio ambiente aquático tem causado crescente preocupação mundial. Além dos relatos de resistência de bactérias a antibióticos, essa classe de fármacos também pode causar efeitos tóxicos e atuar como perturbadores endócrinos em diversos organismos vivos e, possivelmente, em humanos. Dentre os antibióticos comumente usados destacam-se as sulfonamidas, detectadas em águas subterrâneas e superficiais. Os processos avançados de oxidação (POA) têm sido apontados como tecnologias eficientes para tratamento de poluentes recalcitrantes em diferentes matrizes aquosas. Dentre os POA, o processo foto-Fenton é uma alternativa para a degradação de compostos não biodegradáveis, incluindo fármacos. Uma vez que a principal limitação do processo é o intervalo de pH (2,5- 4,0), a reação pode ser vantajosamente conduzida empregando-se substâncias bio-orgânicas solúveis (BOS) como agentes complexantes de Fe3+ em condições ligeiramente ácidas (pH 5). Por sua vez, o emprego da energia ultrassônica tem sido menos estudado. Nesse contexto, o objetivo deste trabalho é estudar a degradação do antibiótico sulfadiazina (SDZ) por meio do processo foto-Fenton na presença de substâncias bio-orgânicas solúveis (UVvis/ Fe3+/H2O2/BOS) e do processo de cavitação por meio de ultrassom (US). Os resultados obtidos mostram que a sulfadiazina é eficientemente degradada por ultrassom de alta frequência. As maiores porcentagens e taxas de remoção são obtidas usando menor frequência de operação (580 kHz), maior potência dissipada e em pH ligeiramente ácido (melhor condição: pH 5,5). Além disso, a reação de Fenton, combinada com o tratamento US, melhorou notavelmente a degradação da SDZ, particularmente quando quantidades extras de H2O2 foram adicionadas ao sistema. Por sua vez, o uso de BOS como aditivos no processo foto-Fenton apresenta influência marcante na fotodegradação da SDZ em condições ligeiramente ácidas (pH 5). Os BOS podem estabilizar espécies de ferro em solução aquosa em pH próximos ao neutro, o que constitui uma propriedade de grande interesse. Sob as condições estudadas, o BOS CVT230 foi mais eficiente do que FORSUD, provavelmente devido às diferenças nos grupos funcionais presentes na composição destas substâncias. Finalmente, foram calculados os indicadores de consumo de energia elétrica por ordem de grandeza (EEO) para o processo de ultrassom (1572 kW h m-3 ordem-1) e área do coletor por ordem de grandeza (ACO) para o processo foto-Fenton (8,07 m2 m-3 ordem-1). / The potential impacts of antibiotic residues in the environment have become an emerging concern during recent years due to their relation with the development of resistant bacteria, and in some cases to their ability to cause toxic and endocrine disrupting effects in humans and other living organisms. Highlighted among the commonly used antibiotics are the sulfonamides, detected in groundwater and surface water. Advanced oxidation processes (AOP) might constitute an important alternative to deal with pharmaceuticals degradation. Among them, the photo-Fenton process has been widely used. One of its major drawbacks is the highly acidic pH needed (2,5-4,0) to avoid the formation of photochemically inactive iron oxides and hydroxides. The ability of soluble bio-organic substances (SBO) to complex metal cations such as iron is useful for the development of photo-Fenton at mild acidic conditions (pH 5). In turn, the use of ultrasonic energy has been less studied. In this context, the aim of this work is to study the degradation of the antibiotic sulfadiazine (SDZ) by the photo-Fenton process in the presence of soluble bio-organic substances (UV-vis/Fe3+/H2O2/SBO) and by ultrasonic cavitation (US). The results confirm that SDZ is effectively degraded by highfrequency ultrasound. Higher SDZ percent removals and removal rates were observed for the lowest operating frequency (580 kHz), higher dissipated power, and in slightly acidic solution (pH 5.5). On the other hand, SDZ degradation is highly improved in the case of the US/ Fe(II)/H2O2 system. The use of the SBO as Fenton additives in turn has a remarkable influence in SDZ photodegradation at slightly acid conditions (pH 5). This could be ascertained to the complexation of iron by the SBO, hence maintained in the reaction medium as a photoactive species. Under the studied conditions, the BOS CVT230 was more efficient than FORSUD, probably due to differences in the functional groups present in the composition of these substances. Finally, the figures-of merit electrical energy per order (EEO) and collector area per order (ACO) were calculated for the ultrasound (1572 kW h m-3 ordem-1) and photo-Fenton (8,07 m2 m-3 ordem-1) processes respectively.
|
87 |
Βeta-bloqueadores em efluente hospitalar: ocorrência, degradação por processos avançados de oxidação e identificação de subprodutos / Βeta-blockers in hospital wastewater; occurence, degradation by advanced oxidation process and byproducts identificationWilde, Marcelo Luís 15 December 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / β-Blockers are an important group of prescription drugs; as a consequence of the large and continuous use, they are commonly found in the environment.
This study assessed, preliminary, the inherent risk of the β-blockers Atenolol, Metoprolol and Propranolol, mostly used in the University Hospital of Santa Maria (HUSM), and showed that Propranolol has high Risk Quotient (RQ) of 0.56.
HPLC-FLD and SPE methodologies were developed and optimized with the aid of experimental design in order to analyze the occurrence of β-blockers in the HUSM sewage system. The average concentration for Atenolol, Metoprolol and Propranolol found for a week sampling were 2.45, 4.67 and 0.70 μg L-1 in the sewage of the Emergence; 0.95, 0.70 and 0.315 μg L-1 in the HUSM main sewage, and 1.26, 1.27 and 0.56 μg L-1 in the water course receptor, respectively,
As possible remediation methodologies for the Hospital Wastewater (HWW) were investigated Advanced Oxidation Process (AOPs) such as photo-Fenton, K2FeO4, Ozonation and O3/Fe2+. The operational parameters were optimized by Response Surface Methodology (RSM). Using optimized conditions for photo-Fenton, Atenolol, Metoprolol and Propranolol were totally degraded in 5 min in aqueous solution, and the mineralization achieved 80% after 120 min of treatment. In HWW, the β-blockers were also totally degraded, however, only 26.5% of the organic matter and 38.6% of the aromaticity were removed. The ready biodegradability and toxicity of the photo-Fenton s samples were estimated by official methods, which indicated an increase in the biodegradability and toxicity. This behavior may be correlated to the formation of degradation products (DPs), relatively, more toxic. The DPs were identified with aid of Liquid Chromatography tandem Mass Spectrometry (LC-MSn).
Other proposed degradation process was oxidation-coagulation using Fe(VI), which achieved above 90% degradation for Atenolol, Metoprolol and Propranolol in HWW, while only 17% COD and 60% aromaticity removal. In aqueous solution this process led to 71.7%, 24.7% and 96.5% degradation of Atenolol, Metoprolol and Propranolol, respectively. No mineralization was found, indicating the formation of DPs, identified by LC-MSn. The ready biodegradability of the post-process samples was tested and the results showed that the oxidation-coagulation with Fe(VI) increased the biodegradability.
The applicability of ozonation was evaluated varying the pH (3-11) for HWW and aqueous solution. More than 95% of the β-blockers were degraded independently of the initial pH, while above 50% of the aromaticity was removed. In aqueous solution the β-blockers were degraded in 10 min treatment and the identification of the DPs were carried out for process pH 5, 7 and 9. Catalytic ozonation (O3/Fe2+) was applied to HWW and a mineralization of 49% was achieved, with 77.9% aromaticity removal. The β-blockers were totally degraded.
Therefore, the present study represents a high qualified analytical information contribution concerning the occurrence of β-blockers in HWW. The studied AOPs/Fe(VI) processes demonstrated to be suitable to degrade Atenolol, Metoprolol and Propranolol. Moreover, high removal of organic matter and aromaticity were achieved by appling O3/Fe2+ process.
In many aspects, this work can be considered original, in especial, by regarding the application of Ferrate(VI) and Catalytic Ozonation to the degradation of β-blockers in HWW. / Os β-bloqueadores são uma importante classe de fármacos prescritos na terapia de doenças cardiovasculares e como consequência de seu grande e contínuo uso são comumente encontrados no meio ambiente.
O presente estudo avaliou preliminarmente o risco inerente dos β-bloqueadores mais usados no Hospital Universitário de Santa Maria (HUSM), Atenolol, Metoprolol e Propranolol, evidenciando que Propranolol apresentou maior risco inerente com Quociente de Risco teórico de 0,56 (risco médio).
Métodos HPLC-FLD e de clean-up/pré-concentração por SPE foram desenvolvidos e otimizados com auxílio de Metodologia de Superfície de Resposta (RSM) para avaliar a ocorrência de β-bloqueadores no sistema de esgotos do HUSM. A concentração ambiental mensurada para Atenolol, Metoprolol e Propranolol durante um ciclo semanal no ponto de lançamento Efluente PA foi 2,45; 4,67 e 0,70 μg L-1, no ponto HUSM principal 0,95; 0,70 e 0,32 μg L-1 e para o Córrego onde os efluentes são lançados de 1,26; 1,27 e 0,56 μg L-1, respectivamente.
Como metodologia de remediação da contaminação de β-bloqueadores em Efluente Hospitalar (EH) foram investigados os Processos Avançados de Oxidação (PAOs) Foto-Fenton, K2FeO4, Ozonização e O3/Fe2+. Os parâmetros operacionais foram otimizados por RSM. Usando as condições otimizadas para o processo Foto-Fenton, Atenolol, Metoprolol e Propranolol foram totalmente degradados em 120 min de tratamento, contudo somente 26,5 e 38,6% da carga orgânica e aromaticidade, respectivamente, foram removidos em EH. A pronta biodegradabilidade e toxicidade para amostras aquosas do processo Foto-Fenton foram analisadas por métodos oficiais e indicaram aumento na biodegradabilidade e toxicidade. Este comportamento esta relacionado à formação de Produtos de Degradação (PD) relativamente mais tóxicos. Os PDs foram identificados por Cromatografia Líquida acoplada a Espectrometria de Massas (LC-MSn).
Outro processo proposto foi oxidação-coagulação com Fe(VI) que alcançou degradação de Atenolol, Metoprolol e Propranolol acima de 90% em EH, enquanto apenas 17 e 60% da matéria orgânica e aromaticidade foram removidos, respectivamente. Em solução aquosa este processo conduziu a degradação de 71,7; 24,7 e 96,5% de Atenolol, Metoprolol e Propranolol, respectivamente. Nenhuma mineralização foi encontrada indicando a formação de PDs, identificados por LC-MSn. A pronta biodegradabilidade para as amostras aquosas pós-processo foram avaliadas e os resultados encontrados mostraram que houve aumento na biodegradabilidade.
A aplicabilidade de ozonização foi avaliada variando o pH de 3-11 em EH e solução aquosa. Mais de 95% dos β-bloqueadores foram degradados independente do pH inicial, enquanto mais de 50% da aromaticidade e 30% da matéria orgânica foram. Em solução aquosa todos os β-bloqueadores foram degradados em menos de 10 min e para os processos em pH 5, 7 e 9 foram identificados os PDs. O processo de O3/Fe2+ alcançou 49% de remoção de matéria orgânica, 77,9% de redução da aromaticidade e completa degradação de Atenolol, Metoprolol e Propranolol em EH.
Portanto, o presente estudo contribui com informação analítica qualificada sobre a ocorrência de β-bloqueadores em EH. Os processos de degradação estudados mostraram-se adequados para a degradação de Atenolol, Metoprolol e Propranolol. Ademais, a maior remoção de matéria orgânica e aromaticidade foram observadas para o processo de O3/Fe2+.
Em muitos aspectos, este trabalho pode ser considerado original, em especial sobre a aplicação de ferrato(VI) e ozonização catalítica para a degradação de β-bloqueadores em EH.
|
88 |
Heterogeneous photo-Fenton treatment of melanoidin wastewater at near neutral pH by ZnO@SnOx@nZVI catalyst on glass fiber / Heterogen foto-Fenton-behandling av avloppsvatten från melanoidin vid nära neutralt pH med ZnO@SnOx@nZVI-katalysator på glasfiberLiu, You January 2024 (has links)
Melanoidin, a high molecular-weight heterogeneous pollutant in the effluents of molasses-using industries, poses a significant threat to the environment due to its non-biodegradability, unpleasant odour, and harmful effect. Various advanced oxidation processes (AOPs) that produce reactive oxygen species (ROS) are used for the degradation of melanoidins. Heterogeneous photo-Fenton process has emerged as a promising alternative approach in wastewater treatment owing to its enhanced catalytic activity, lower hydrogen peroxide (H2O2) consumption, and reusability of the catalyst. In this work, we investigated the photo-Fenton oxidation of melanoidins using heterogeneous catalyst ZnO@SnOx@nZVI supported on a flexible substrate. The effects of reaction pH, amount of catalyst and H2O2 on color and chemical oxygen demand (COD) removal, as well as the removal kinetics, were studied. It is found that the developed heterogeneous catalyst can lead to 97.3% decolorization of melanoidin (7000 COD) after 4 hours irradiation of simulated sunlight at pH 6 with a much lower dosage of H2O2 than the stoichiometric ratio with respect to COD. The generation of ·OH free radicals and residual H2O2 were monitored to understand the mechanism of melanoidin degradation at near-neutral pH with insufficient H2O2. The findings of this work have significant implications in treatment of non-biodegradable organic pollutants, owing to the advantages in avoiding low pH treatment condition, reducing the cost of H2O2, and enhanced chemical stability of photo-Fenton catalyst. / Melanoidin, en heterogen förorening med hög molekylvikt i avloppsvatten från industrier som använder melass, utgör ett betydande hot mot miljön på grund av dess icke-biologiska nedbrytbarhet, obehagliga lukt och skadliga effekt. Olika avancerade oxidationsprocesser (AOP) som producerar reaktiva syreföreningar (ROS) används för nedbrytning av melanoidiner. Heterogen foto-Fenton-process har framstått som ett lovande alternativ för avloppsrening på grund av dess förbättrade katalytiska aktivitet, lägre väteperoxid (H2O2) förbrukning och återanvändbarhet av katalysatorn. I detta arbete undersökte vi foto-Fenton-oxidationen av melanoidiner med hjälp av heterogen katalysator ZnO@SnOx@nZVI som stöds på ett flexibelt substrat. Effekterna av reaktionens pH, mängden katalysator och H2O2 på färg och avlägsnande av kemisk syreförbrukning (COD), liksom avlägsnandets kinetik, studerades. Det visade sig att den utvecklade heterogena katalysatorn kan leda till 97,3% avfärgning av melanoidin (7000 COD) efter 4 timmars bestrålning av simulerat solljus vid pH 6 med en mycket lågre dosering av H2O2 än det stökiometriska förhållandet med avseende på COD. Generering av ·OH fria radikaler och kvarvarande H2O2 övervakades för att förstå mekanismen för nedbrytning av melanoidin vid nära neutralt pH med otillräcklig H2O2. Resultaten av detta arbete har betydande konsekvenser vid behandling av icke- biologiskt nedbrytbara organiska föroreningar, på grund av fördelarna med att undvika behandlingsförhållanden med lågt pH, minska kostnaden för H2O2 och förbättrad kemiska stabilitet hos foto-Fenton-katalysatorn.
|
89 |
Proceso foto-Fenton como una alternativa en la degradación de microplásticos de poliamida presentes en aguas residuales textilesMarcelino Pérez, Edgar 16 January 2023 (has links)
[ES] La alta escasez de agua y el constante incremento en la industrialización ha propiciado el deterioro de las reservas de agua como consecuencia de la excesiva generación y liberación de desechos contaminantes. Actualmente, se han reportado una gran variedad de contaminantes de diferente naturaleza, entre ellos se pueden mencionar los microplásticos (MPs) que han sido detectados en agua potable e incluso en animales para la ingesta humana lo cual puede acarrear graves problemas de salud. Cabe mencionar que uno de los mayores problemas a nivel medioambiental de los MPs radica en su alta estabilidad, ya que los métodos habituales utilizados para la eliminación de contaminantes no ejercen efecto.
En este sentido, los Procesos de Oxidación Avanzada (POAs) han surgido como una alternativa a la eliminación de contaminantes de difícil degradación, debido a la generación principalmente de radicales hidroxilo que tienen un elevado potencial de oxidación y son muy poco selectivos. En este trabajo nos hemos centrado en el uso del proceso foto-Fenton, con sales de hierro y peróxido de hidrógeno e utilizando la luz solar como fuente de radiación, para llevar a cabo la degradación de MPs, específicamente la poliamida 6,6 (PA66), a pesar de que este polímero no es propiamente un plástico, la literatura lo considera dentro de ellos debido a su importancia como contaminante.
A partir de PA66 obtenida de la industria textil, se evaluó el proceso de degradación con distintas técnicas y métodos analíticos destacando entre ellos la microscopía FESEM y la espectroscopía TF-IR. Se realizaron estudios en simulador solar en condiciones habituales de trabajo de procesos foto-Fenton (5 mg/L de Fe, 10 mg/L de H2O2 y pH = 2.8) y qué efectos podían producir tanto el tiempo de radiación como la presencia de una matriz natural como la salinidad en las aguas de tratamiento. Además, se realizaron estudios para confirmar que el proceso de degradación de la PA66 observado (numerosas imperfecciones aparecieron en la superficie del microplástico) era debido a la acción tanto del radical hidroxilo como del radical superóxido utilizando secuestrantes de ambos y comparando los procesos.
Posteriormente se evaluó la degradación de la PA66 a nivel planta piloto utilizando dos diferentes fuentes de irradiación: LED vis y LED vis + solar realizando para ello, un estudio previo de diseño de experimentos tipo Doehlert para minimizar recursos y residuos y obtener las óptimas condiciones de tratamiento de la PA66 y, con base a estas condiciones se comparó la degradación de 4 diferentes MPs: PA66, poliamida 6 (PA6), aramida y poliéster (PES). Por último, se estudió la degradación de la PA66 bajo estas mismas condiciones en un periodo de 100 h.
Los estudios de estabilidad mostraron que la PA66 no presenta fotólisis ni hidrólisis y los ensayos de degradación mediante el proceso foto-Fenton en un periodo de 7 h mostraron la formación de defectos sobre la superficie de la PA66 y disminución de grupos funcionales de acuerdo microscopia FESEM y FTIR, asimismo, el MP mostró cambios en su punto de fusión a diferentes tiempos de tratamiento como consecuencia de la rotura de las cadenas del polímero. Este mismo efecto se observó en un tiempo de degradación de 100 h de la PA66 con un aumento en el número y diámetro de defectos formados.
La adición de NaCl a 30 g/L (alta salinidad) provocó una disminución en el daño generado debido a la reacción de los radicales hidroxilo y formación de especies reactivas con menor potencial de oxidación. La adición de 2-propanol y p-benzoquinona como atrapadores del radical hidroxilo y anión superóxido corroboraron esta suposición.
La PA66 tratada en planta piloto mediante el uso de radiación LED vis + solar presentó un mayor grado de degradación en comparación con la tratada únicamente con radiación LED vis (incremento de 90 veces más el área superficial especifica de la PA66 tratada con respecto a la PA66 sin tratamiento). / [CA] L'alta escassetat d'aigua i el constant increment en la industrialització ha propiciat la deterioració dels cossos d'aigua a conseqüència de l'excessiva generació i alliberament de deixalles contaminants. Actualment, s'han reportat una gran varietat de contaminants de diferent naturalesa, entre ells es poden esmentar els microplàstics (MPs) que han sigut detectats en aigua potable i fins i tot en animals per a la ingesta humana la qual cosa pot implicar greus problemes de salut. Cal esmentar que un dels majors problemes a nivell mediambiental dels MPs radica en la seua alta estabilitat, ja que els mètodes habituals utilitzats per a l'eliminació de contaminants no exerceixen cap efecte.
En aquest sentit, els Processos d'Oxidació Avançada (POAs) han sorgit com una alternativa a l'eliminació de contaminants de difícil degradació, a causa de la generació principalment de radicals hidroxil que tenen un elevat potencial d'oxidació i són molt poc selectius. En aquest treball ens hem centrat en l'ús del procés foto-Fenton, amb sals de ferro i peròxid d'hidrogen e utilitzant la llum solar com a font de radiació, per a dur a terme la degradació de MPs, específicament la poliamida 6,6 (PA66).
A partir de PA66 obtinguda de la indústria tèxtil, es va avaluar el procés de degradació amb diferents tècniques i mètodes analítics destacant entre ells la microscòpia FESEM i la espectroscopía FT-IR. Es van realitzar estudis en simulador solar en condicions habituals de treball de processos foto-Fenton (5 mg/L de Fe, 10 mg/L de H2O2 i pH = 2.8) i quins efectes podien produir tant el temps de radiació com la presència d'una matriu natural com la salinitat en les aigües de tractament. A més, es van realitzar estudis per a confirmar que el procés de degradació de la PA66 observat (nombroses imperfeccions van aparèixer en la superfície del microplàstic) era degut a l'acció tant del radical hidroxil com del radical superòxid utilitzant segrestants de tots dos i comparant els processos.
Posteriorment es va avaluar la degradació de la PA66 a nivell planta pilot utilitzant dues diferents fonts d'irradiació: LED vis i LED-vis + solar realitzant per a això, un estudi previ de disseny d'experiments tipus Doehlert per a minimitzar recursos i residus i obtindre les òptimes condicions de tractament de la PA66 i, amb base a aquestes condicions es va comparar la degradació de 4 diferents MPs (PA66, PA6, Aramida i PES). Finalment, es va estudiar la degradació de la PA66 sota aquestes mateixes condicions en un període de 100 h.
Els estudis d'estabilitat van mostrar que la PA66 no presenta fotòlisis ni hidròlisi i els assajos de degradació mitjançant el procés foto-Fenton en un període de 7 h van mostrar la formació de defectes sobre la superfície de la PA66 i disminució de grups funcionals d'acord microscòpia FESEM i FT-IR, així mateix, el MP va mostrar canvis al punt de fusió a diferents temps de tractament a conseqüència del trencament de les cadenes del polímer. Aquest mateix efecte es va observar en un temps de degradació de 100 h de la PA66 amb un augment en el nombre de defectes formats i diàmetre dels defectes.
L'addició de NaCl a 30 g/L (alta salinitat) va provocar una disminució en el mal generat a causa del secuestrament dels radicals hidroxil i formació d'espècies reactives amb menor potencial d'oxidació. L'addició de 2-propanol i p-benzoquinona com atrapadores del radical hidroxil i anió superòxid van corroborar aquesta suposició.
La PA66 tractada en planta pilot mitjançant l'ús de radiació LED-vis + solar va presentar un major grau de degradació en comparació amb la tractada únicament amb radiació LED-vis (increment de 90 vegades més l'àrea superficial especifica de la PA66 tractada respecte a la PA66 sense tractament).
L'avaluació de la degradació dels 4 MPs va mostrar que el PES i la aramida no són degradables en aquestes condicions i la PA6 va presentar una menor degradació que la PA66. / [EN] The high scarcity of water and the constant increase in industrialization has led to the deterioration of water bodies as a consequence of the excessive generation and release of pollutant wastes. Currently, a great variety of pollutants of different nature have been reported, among them we can mention microplastics (MPs) that have been detected in drinking water and even in animals for human consumption, which can cause serious health problems. It is worth mentioning that one of the biggest environmental problems of MPs lies in their high stability, since the usual methods used for the elimination of contaminants have no effect.
In this sense, Advanced Oxidation Processes (AOPs) have emerged as an alternative for the removal of pollutants that are difficult to degrade, mainly due to the generation of hydroxyl radicals that have a high oxidation potential and are not very selective. In this work we have focused on the use of the photo-Fenton process, with iron salts and hydrogen peroxide and using sunlight as a source of radiation, to carry out the degradation of PMs, specifically polyamide 6,6 (PA66), despite that this polymer is not a plastic, literature considers it among them due to its importance as a pollutant.
Using PA66 obtained from the textile industry, the degradation process was evaluated with different techniques and analytical methods, among them FESEM microscopy and TF-IR spectroscopy. Studies were carried out in a solar simulator under usual working conditions of photo-Fenton processes (5 mg/L Fe, 10 mg/L H2O2 and pH = 2.8) and it was studied the effect by the radiation time and the presence of a natural matrix such as salinity in the treatment water. In addition, studies were conducted to confirm that the PA66 degradation process observed (numerous imperfections appeared on the surface of the microplastic) was due to the action of both oxygen species (hydroxyl radical and the superoxide radical) by using scavengers of both and comparing the processes.
Subsequently, PA66 degradation was evaluated at pilot plant level using two different irradiation sources: LED vis and LED vis + solar, a previous study of Doehlert type design of experiments to minimize resources and waste and obtain the optimal conditions for PA66 treatment and, based on these conditions the degradation of 4 different MPs: PA66, polyamide 6 (PA6), aramid and polyethylene (PES) was compared. Finally, the degradation of PA66 under these same conditions was studied over a period of 100 h.
The stability studies showed that PA66 does not present photolysis or hydrolysis and the degradation tests by the photo-Fenton process in a period of 7 h showed the formation of defects on the surface of PA66 and decrease of functional groups according to FESEM and FTIR microscopy, also, the MP showed changes in its melting point at different treatment time as a result of the breaking of the polymer chains. This same effect was observed at a degradation time of 100 h of PA66 with an increase in the number of defects formed and in their diameters.
The addition of NaCl at 30 g/L (high salinity) caused a decrease in the damage generated due to the reaction of hydroxyl radicals and formation of reactive species with lower oxidation potential. The addition of 2-propanol and p-benzoquinone as hydroxyl radical and superoxide anion scavengers corroborated this assumption.
PA66 treated in pilot plant using LED vis + solar irradiation showed a higher degree of degradation compared to PA66 treated only with LED vis irradiation (90-fold increase in the specific surface area of treated PA66 with respect to untreated PA66).
The evaluation of the degradation of the 4 MPs showed that PES and aramid are not degradable under these conditions and PA6 presented a lower degradation than PA66. / Marcelino Pérez, E. (2022). Proceso foto-Fenton como una alternativa en la degradación de microplásticos de poliamida presentes en aguas residuales textiles [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/191335
|
90 |
Aplicação dos processos foto-Fenton e eletrofloculação no tratamento de efluente de curtume / Application of the photo-Fenton and electrocoagulation processes at the tannery effluent treatmentBorba, Fernando Henrique 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:12Z (GMT). No. of bitstreams: 1
Fernando Henrique Borba.pdf: 3301834 bytes, checksum: 0c5216d667957cc99d5acd2dd5d59c05 (MD5)
Previous issue date: 2010-02-18 / Pollution is a currently environmental problem of world concern. There are many events such as the discharging of untreated effluents in watercourses that cause the eutrophization of water bodies and bad water quality, as well as an inefficiency or lack of a current environmental law. The main goal of this dissertation was the application of solar and artificial-based photo-Fenton processes and aluminum electrodes-based electrocoagulation method in non coupled mode and in an integrated mode for the tannery effluent treatment. These effluent treatments were carried out in lab-scale reactors. In order to evaluate the performance of the reactor experimental conditions of photo-Fenton reactor, a 33 complete experimental design was performed. The lab scale EC reactor was operated at the 4 A electrical current, 4 cm electrode distance and 3 initial pH optimized values, according to the previous results obtained in another work, while the electrolysis time was varied from 5 to 120 min. For EC and photo-Fenton reactors, their performance was evaluated on the removal values of chemical oxygem demand (COD), color, turbidity, total solids (TS), total fixed solids (TFS), total volatile solids (TVS) and metal concentration. Measurements of physico-chemical parameters for untreated and treated effluent samples were performed applying the Standard Method for water analysis, while metal concentrations were determined by the Synchrotron radiation total Reflexion X-ray Fluorescence technique at Brazilian Light Synchrotron Laboratory. By an optimized photon-Fenton process at 0.5 g Fe2+ L-1, 30 g H2O2 L-1, 3 initial pH, and 120 min reaction time, tannery effluent was treated achieving a high performance in pollutant removal as reported by 98.1, 96.4, 98.8, 71.8, 32.1 and 98.5 percent removal for COD, color, turbidity, TS, TFS, and TVS, respectively. As a primer treatment stage, electrocoagulation technique was not achieved a well successful result based on the physico-chemical parameter values reduction as compared with photo-Fenton process. However, an integrated solar irradiation-based photo-Fenton and Al electrodes-based electrocoagulation with 15 min electrolysis time has achieved recommended values by the Brazilian environmental law for Cr concentration (0.24 mg Cr L-1) and DQO (107 mg O2 L-1). Considering both the costs of electrical energy and material and the generated sludge discharging, one m3 of tannery effluent should cost R$ 56.30 for a treatment system based on an integrated and optimized photo Fenton and electrocoagulation processes. Finally, the integrated solar-based photo Fenton and electrocoagulation method is suggested as an efficient one, instead to apply a unique process. / A poluição ambiental é um dos grandes problemas nos países desenvolvidos e em desenvolvimento. Isto é decorrente de uma série de fatores, como o despejo de efluentes não tratados em corpos hídricos e a ineficiência e/ou a falta de legislação ambiental vigente. O objetivo principal deste trabalho é aplicar os processos foto-Fenton com irradiação solar e/ou artificial, a técnica da eletrofloculação e a integração destes processos no tratamento de efluente de curtume. Ambos os processos de tratamento do foto-Fenton e da eletrofloculação foram conduzidos em reatores a escala laboratorial. Para a técnica da eletrofloculação foi utilizado um par de placas de alumínio como eletrodos no reator de eletrofloculação. Para avaliar as melhores condições de processo do sistema foto-Fenton, foi aplicado um planejamento experimental 33 completo. Para a técnica da eletrofloculação manteve-se constante a intensidade de corrente, pH inicial do efluente bruto e distância entre os eletrodos, variando-se o tempo de eletrólise de 5 à 120 min. A eficiência de ambos os processos foram avaliadas com base na redução de Demanda química de oxigênio (DQO), cor, turbidez, sólidos totais (ST), sólidos totais fixos (STF), sólidos totais voláteis (STV). Para a técnica da eletrofloculação e dos processos integrados também foram avaliados a redução da concentração dos metais pesados. Todas as medidas dos parâmetros físico-químicos foram realizadas aplicando os métodos padrões do Standard Methods for the Examination of Water and Wastewater para amostra não tratada e tratada. As concentrações dos metais pesados foram determinadas usando a técnica de fluorescência de raio X por reflexão total, na linha de Luz (D09-XRF) do Laboratório Nacional de Luz Synchrotron. A maior eficiência na redução dos poluentes verificada no processo foto-Fenton foi de 98,1, 96,4, 98,8, 71,8, 32,1 e 98,5 para valores da DQO, cor, turbidez, ST, STF e STV, respectivamente, nas condições operacionais do reator: concentração de ferro de 0,5 gL-1, concentração de peróxido de hidrogênio de 30 gL-1, pH inicial 3 e tempo reacional de 120 min. No entanto a técnica da eletrofloculação não apresentou boa redução nos valores dos parâmetros físico-químicos. Após a aplicação dos processos integrados do foto-Fenton com irradiação solar e da eletrofloculação em tempo de eletrólise de 15 min, foi alcançado valores mínimos de Cr e DQO no efluente tratado, contendo 0,24 mg Cr L-1 e 107 mg O2 L-1 da DQO. O custo do tratamento do efluente e da disposição final do lodo gerado no processo integrado FFs→EF foi de R$ 56,30 m3 do efluente de curtume tratado. Este processo integrado reduziu as concentrações de cromo, ferro e DQO, a níveis permitidos pelas legislações ambientais. Baseada na redução da matéria orgânica e inorgânica, o método integrado FFs→EF pode ser recomendado como uma substituição eficiente ao método individual.
|
Page generated in 0.0588 seconds