• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 2
  • Tagged with
  • 25
  • 8
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Patientens upplevelse av illamående vid cytostatikabehandling via portabel infusionspump : Kvalitativ intervjustudie

Susekova, Tatiana January 2023 (has links)
Patientens upplevelse av illamående vid cytostatikabehandling via portabel infusionspump - Kvalitativ intervjustudie.  Bakgrund: Arbetet handlar om att få cytostatikabehandling via portabel infusionspump då detta är en metod som implementeras i allt fler behandlingsformer. Flertalet studier beskriver de positiva effekterna för patienten och sjukvården, däribland påverkan på patientens upplevelse av illamåendet. Tidigare studier visar att cytostatikabehandling via portabel pump kan bidra till ökad livskvalitet, ökad känsla av kontroll på sig själv och sin vardag, samt lägre grad av cytostatikainducerade biverkningar, däribland illamående. Motiv: På grund av avsaknaden av konkreta studier som tar upp hur biverkningen illamående påverkas av cytostatikabehandling via portabel pump har skribenten valt att försöka tydliggöra om patienternas upplevelse av illamående under en cytostatikabehandling kan förändras beroende på omgiven miljö. Syfte: Att belysa erfarenhet av illamående vid cytostatikabehandling via portabel infusionspump på och utanför sjukhus. Metod: Åtta patienter intervjuades genom semistrukturerade intervjuer med en kvalitativ design. Intervjuerna analyserades enligt innehållsanalys med induktiv ansats. Resultat: Studien mynnade ut i två kategorier: Vård utanför sjukhuset och Sjukhusmiljön på vårdavdelning. Kategorierna delades sedan upp i fyra underkategorier: Flyttat fokus från sjukdom till hopp, Kunskap om hur illamående kan förebyggas och behandlas, Illamående på grund av sjukhusmiljön och Känslan av att vara begränsad och kontrollerad. Konklusion: Patientens autonomi, känslan av sammanhang och förmågan till egenvård i relation till miljön vid erhållen cytostatikabehandling påverkar patientens upplevelse av illamående. / Patients’ experience of nausea during chemotherapy via portable infusion pump - Qualitative interview study. Background: The study is about receiving chemotherapy via a portable infusion pump due to that this method in healthcare is being implemented in more forms of treatments. Many studies are describing the positive effects for the patient and the experience of nausea and the healthcare. Previous studies show that chemotherapy via a portable infusion pump can contribute to increased quality of life, a greater sense of control over oneself and one’s everyday life, and a lower degree of chemotherapy induced side effects, including nausea. Motive: Due to lack of studies that address how nausea is affected by chemotherapy via portable infusion pump, the writer has chosen to try to clarify whether the patients’ experience of nausea during a chemotherapy treatment can change depending on the surrounding environment. Aim: To highlight the experience of nausea during chemotherapy treatment via portable infusion pump in and out of hospital. Methods: Eight patients were interviewed true semi-structured interviews, with a qualitative design. The interviews were further analyzed true a content analysis with an inductive approach. Result: The study resulted in two categories: “Care out of hospital” and “The hospital environment in the care department”. The categories were further divided into four subcategories: “Shifted focus from illness to hope”, “Knowledge of how nausea can be prevented and treated”, “Nausea due to hospital environment and “The feeling of being limited and controlled”. Conclusion: Patient’s autonomy, the sense of coherence and the ability to self-care in relation to the environment when receiving chemotherapy affect the patient’s experience of nausea.
22

Utveckling av en kompakt BLE-modul i en portabel EKG : Med möjlighet till kontinuerlig dataöverföring / Development of a Compact BLE Module in an Portable ECG : With the possibility of continuous data transfer

Attrell, Henrik, Holmqvist, Mattias January 2022 (has links)
Elektrodiagram eller EKG används inom sjukvården för att mäta hjärtats elektriska aktivitet med hjälp av flera elektroder som placeras ut på kroppen. Från mätningarna kan indikationer på hjärtsjukdomar och störningar i hjärtrytm upptäckas och sedan behandlas. Hjärt- och kärl-sjukdomar är den vanligaste dödsorsaken i Sverige och behovet av EKG undersökningar är stort. Vanligtvis är EKG-apparaterna stora, otympliga och begränsade till sjukhus då de är komplicerade och dyra. Linköpings universitets forskningsgrupp tillsammans med flera examensarbeten har då tagit fram en prototyp på en kompakt och portabel EKG. Den portabla EKG-apparaten kopplas med en sele som är integrerad med elektroder och ska brukas av främst kvinnor, då utbudet av användarvänliga EKG:s till kvinnor är litet. Den tidigare portabla EKG:en är uppbyggd av två moduler, EKG-modulen och Nordic Thingy52. EKG-modulen konstruerad på ett specialanpassat kretskort som utför den faktiska mätningen av elektroderna och uträkningar. Den är sedan ihopkopplad med Thingy52 som ansvarar för den trådlösa kommunikationen till andra enheter via Bluetooth Low Energy eller BLE som det också kallas. BLE-modulen som innefattade Thingy52 och den modifierade källkoden från tidigare arbeten, klarade av viss trådlös kommunikation men ansågs vara förlångsam och klarade inte av kontinuerlig dataöverföring. Från de tidigare arbetena uppkom då frågeställningar om det var möjligt att vidareutveckla den tidigare BLE-modulen genom att förbättra dataöverföring och införa fler funktioner. De mest väsentliga önskemål var att optimera modulens dataöverföring till att bli kontinuerlig, införa funktionalitet för att spara mätvärden som en typ av backup och introducera ett enklare digitalt filter för att filtrera bort brus och störningar på mätvärdena. Utöver detta skulle även ett kompaktare och mindre kretskort till BLE-modulen tas fram som skulle ersätta Thingy52. Projektet började med att införskaffa kunskap och förståelse om hur befintliga och tillkommande funktioner samt tjänster fungerar samt hur de ska implementeras. Val om vilka komponenter och utvecklingsmiljöer som skulle användas under projektet fastställdes. Valen resulterade i att fortsätta med tidigare System-on-chip, SoC nRF52832 från Nordic Semiconductor som Thingy52 är utformad runt. Detta ledde till att befintliga utvecklingskort kunde användas och kretsschema från Thingy52 kunde återanvändas till det nya kretsschemat. Innan det eget skapade kretskortet kunde beställas och testas behövdes verifiering av att den valda SoC klarade av kontinuerlig dataöverföring. Detta kunde utföras på utvecklingskort nRF52 SDK med samma typ av SoC. Verifieringen av dataöverföringen var mer tidskrävande än vad som hade räknats med och tyvärr blev det inte tid att beställa kretskortet och kunde inte testas i praktiken. Ett kretsschema utfördes ändå som har mindre dimensioner än Thingy52 och innehåller de önskade delarna. Under utveckling av BLE-funktionen valdes det att använda Nordic:s nya utvecklingsmiljö som förenklade programmering av avancerade funktioner, till exempel BLE. Valet av att byta utvecklingsmiljö resulterade dock i att tidigare programmeringskod som hanterade konfigurering och dataöverföring med EKG-modulen, behövdes konverteras om till ett nytt operativsystem efter att Nordic bytt till operativsystemet Zypher. Detta gav i följd att funktioner och bibliotek inte stödes eller inte fanns. Efter detta flyttades fokuset till att implementera och integrera lagringsfunktionen med BLE- och EKG-funktionerna. Multitrådning infördes för att kunna utföra och optimera BLE-modulens funktioner. Tidsbrist gjorde att endast platshållare för framtida implementering av digitala filter kunde utföras. Utifrån de testresultaten över BLE-modulen är det även svårt att garantera att SoC hinner utföra filtrering av mätdata under det redan begränsade tidsintervallet. Efter en del problem och många tester resulterade examensarbetet slutligen i ett kompakt kretsschema som skulle kunna ersätta Thingy52. En BLE-modul som kan utföra dataöverföring med viss kontinuerlighet och samtidigt lagra mätdata till ett SD-kort utan att påverka kommunikationen med EKG-modulen eller användargränssnittet. Slutprodukten har även många möjligheter att utökas i framtida arbeten. / Electrocardiography or ECG is used in healthcare to measure the electrical activity of the heart using several electrodes that are placed on the body. From the measurements, indications of heart diseases and heart rhythm disorders can be detected and then treated. Cardiovascular disease is the most common cause of death in Sweden and the need for ECG examinations is great. Usually the ECG devices are large, awkward, and limited to hospitals as they are complicated and expensive. Linköping University's research group together with several bachelor thesis projects has developed a prototype of a compact and portable ECG. The portable ECG device is connected to a bra that is integrated with electrodes and should be used mainly by women, as the range of user-friendly ECGs for women is small. The previously portable ECG is made up of two modules, the ECG module, and the Nordic Thingy52. The ECG module is designed on a specially adapted circuit board that performs the actual measurement of the electrodes and calculations. It is then paired with Thingy52 which is responsible for the wireless communication to other devices via Bluetooth Low Energy or BLE as it is also called. The BLE module, which included Thingy52 and the modified source code from previous work, managed some wireless communication but was considered too slow and could not handle continuous data transfer. From the previous work questions arose as to whether it was possible to further develop the previous BLE module by improving data transfer and introducing more features. The most desired features were to optimize the module's data transfer to become continuous, implement functionality to save measured values as a type of backup and implement a simple digital filter to filter out noise and disturbances of the measured values. In addition to this, a more compact and smaller circuit board for the BLE module would also be developed that would replace the Thingy52. The project began with acquiring knowledge and understanding of how existing and additional functions or services work and how they should be implemented. Choices about which components and development environments would be used during the project were determined. The choice resulted in continuing with the previous System-on-chip, SoC nRF52832 from Nordic Semiconductor around which Thingy52 is designed. As a result, existing development boards could be used and the circuit diagram from Thingy52 could be reused for the new circuit diagram. Before the self-created circuit board could be ordered and tested, verification was needed to determine that the selected SoC was capable of continuous data transfer. This could be done on development card nRF52 SDK with the same type of SoC. The verification of the data transfer was more time consuming than had been expected and unfortunately there was no time to order the circuit board and therefore could not be tested in practice. A circuit diagram was nevertheless performed which has smaller dimensions than Thingy52 and contains the desired parts. During the development of the BLE function, it was chosen to use Nordic's new development environment as it simplified programming of advanced functions, like BLE. The choice to change the development environment, however, resulted in the previous programming code, which handled configuration and data transfer with the ECG module, having to be converted to a new operating system after Nordic switched to the Zypher operating system. As a result, functions and libraries were not supported or did not exist. After this, the focus shifted to implementing and integrating the storage function with the BLE and ECG functions. The multithreading tool was introduced to perform and optimize the functions of the BLE module. Lack of time meant that only placeholders for future implementation of digital filters could be performed. Based on the test results over the BLE module, it is also difficult to guarantee that the SoC has time to perform filtering of measurement data during the already limited time interval. After some problems and many tests, the bachelor thesis project finally resulted in a compact circuit that could replace Thingy52. Also, a BLE module that can perform data transfer with some continuity and at the same time store measurement data to a SD card without affecting the communication with the ECG module or the user interface. The end product also has many opportunities to be expanded in future work.
23

Portabel mätplattform med låg effektförbrukning för datainsamling i fält / Portable Low-Power Data Logger for Debugging Applications in the Field

Nygård, Linus, Wallén, Marika January 2022 (has links)
Denna rapport presenterar en design och implementation av en portabel mätplattform ämnad för felsökning genom datainsamling av olika industriella signaler i fält. Konstruktionen kan mäta ±10 V och strömslinga, för att sedan logga dessa till ett SD-kort. Implementationen utfördes med hjälp av färdiga enkortslösningar i form av en Arduino Uno och diverse expansionskort, även kallade shields. Fokus i projektet har legat på att minimera strömförbrukningen av den mikrokontrollbaserade mätplattformen med olika hårdvaru- och mjukvarumetoder. Det resulterade i att den slutgiltiga produkten använde sig av mjukvarumetoder för att minimera strömförbrukningen. Detta var för att omkonstruktioner av hårdvara skulle vara både krångligt och mer tidskrävande än att använda sig av strömeffektiva funktioner i mjukvaran. Arduino Uno visade sig även vara den mikrokontrollen som passade bäst för att minimera strömförbrukningen men ett sämre alternativ om man ville behålla en hög samplingshastighet då klockhastigheten och minnet inte räckte till. Sammanfattningsvis kan man säga att projektet blev lyckat då majoriteteten av önskemålen från kravspecifikationen blev uppfyllda. Det finns även en del förbättringsförslag man kan jobba vidare med. Till exempel en förbättrad prestanda och egendesignade kretskort. / This report presents the design and implementation of a portable data logger for debugging by logging different industrial signals in the field. The finished product can measure ±10 V and current loop signals. These are then logged to an SD card. The product was implemented using ready-made electronics boards such as the Arduino Uno microcontroller board and compatible expansion cards, also known as shields. The projects main focus is on minimizing the power consumption of the microcontroller based data logger through the use of different hardware- and software methods. The finished product mainly uses software solutions to achieve this. The main reason is that redesigns in hardware would be more difficult and time consuming. The Arduino turned out to be a very good microcontroller for low-power applications, although not optimal if higher sampling speeds are desired because of its limited clock speed and internal memory. In conclusion, the project was a success and most of the goals set out in the beginning where accomplished but there are some improvements that can be made to the product. Some suggested improvements are higher performing internals and circuit boards specifically designed for the application.
24

Effekt av artikulationsträning med visuell återkoppling hos en vuxen person med hemifacial mikrosomi och talstörning

Berglund, Ingrid January 2016 (has links)
Syftet med denna studie var att utvärdera behandling med hjälp av elektropalatografi (EPG) och portabel träningsenhet (PTU) hos en person med kvarstående artikulationsproblem. Försökspersonen var en vuxen man med medfödd hemifacial mikrosomi och mikrognati som tidigare genomfört konventionell talträning. En kvasiexperimentell, prospektiv, kontrollerad single subjekt A-B-A design användes. Försökspersonen hade vid träningsstart en tillbakadragen artikulation av /t/ och /d/ till velart/uvulart artikulationsställe med kvarstående svårighet att göra sitt tal förståeligt för sina samtalspartners.  Behandlingseffekten utvärderades genom instrumentell EPG analys av /t/ i enstaka ord före och efter behandling. Analysen visade signifikanta behandlingsresultat där en fortgående förbättring av produktionen av /t/ i medial och final position skedde även fyra år efter avslutad behandling. Perceptuell lyssnarbedömning av tränade och otränade lyssnare uppvisade signifikant förbättrad skattning av t-likhet av målljudet /t/ i medial och final position över tid. Ett mycket svagt samband sågs mellan perceptuell skattning av t-likhet och de analyserade EPG-värdena. Lyssnarskattningen av spontantalet visade en förbättring av förståelighet vid kontroll 4 år efter avslutad träning. Utvärderingen bekräftar tidigare forskning och visar att talträning med EPG är ett effektivt sätt att ge visuell återkoppling i försök att etablera ett korrekt artikulationsmönster, förbättrat tal och ökad förståelighet. Detta provades i föreliggande studie och även om resultaten inte var entydiga, antyddes att metoden kan vara långsiktigt framgångsrik vid sedan lång tid väl etablerade talavvikelser utan tecken på förändring spontant eller efter tidigare träning utan visuell återkoppling. En viktig erfarenhet är således att planera långsiktigt och invänta automatisering av nya artikulationsrörelser som har lång etableringsfas. Träning med EPG föreslås kunna erbjudas vuxna personer med kvarstående artikulationsavvikelser där konventionell träning inte har kunnat ge önskvärda resultat. Nyckelord: Elektropalatografi, behandlingseffekt, hemifacial mikrosomi, artikulationsstörning, långtidsuppföljning, förståelighet / The aim of this study was to evaluate speech therapy using electropalatography (EPG) and portable training unit (PTU) in a subject with persistent articulation errors. The participant was a male adult with congenital hemifacial microsomia and micrognathia who previously had received conventional speech therapy. The subject had a retracted, velar/ uvular articulation of dental plosives with difficulty making speech understandable to listeners. A quasi-experimental prospective, controlled single-subject ABA design was used. Treatment efficacy was assessed by instrumental EPG analysis of  /t/ in single words before and after treatment and showed significant treatment results with a continuing improvement in the production of  /t/ in medial and final position even four years after completion of treatment. Perceptual listen assessment of trained and untrained listeners showed significantly improved estimation of the target /t/ in medial and final position over time. A very weak association was found between the perceptual estimation of t-likeness and the analyzed EPG values. Listener rating of spontaneous speech showed an improvement in intelligibility 4 years after completing training. The evaluation confirms previous research showing that speech therapy with EPG seems effective for providing visual feedback in the attempt to establish a correct articulation pattern, improved speech and enhanced intelligibility. This was investigated in the present study and although the results were not unambiguous, it was indicated that the method can be successful at long persisting well established articulation errors without signs of spontaneous change or after previous training without visual feedback. An important experience is to plan long term and wait for the automation of the new articulation movements that have a long establishment phase. Training with EPG is proposed to be offered to adults with persistent articulation disorders for which conventional therapy has been unable to provide desirable results. Keywords:  Electropalatography, treatment effect, hemifacial microsomia, articulation disorder, long- term follow- up, intelligibility
25

En arkeologi av det animistiska : Om den mesolitiska ornamentiken i Östersjöområdet / An Archaeology of Animacy : On the Mesolithic Ornamentation of the Baltic Sea

Solfeldt, Erik January 2021 (has links)
This thesis is focused on the material known as the Mesolithic portable art. Earlier research have interpreted the material as representative art relating to ideology, mythology, prestige, ritual practices,and tribalism. Such interpretations are based on theoretical frameworks that build on hylomorphism and Cartesian metaphysics. By a change of theoretical framework, to a new animistic perspective based on a combination of Gilles Deleuze and Félix Guattari’s rhizome theory, Tim Ingold’s meshwork and Giordano Bruno’s theory of bonds in general, followed by the use of ChantalConneller’s method rhizomatic chaîne opératoire, I conclude that the motifs on the tools and pendants are communications to the animated subjects that make up and inhabit the environment. Furthermore, I conclude that the binary positions of function and ritual cannot be applied when studying the formgenerating process of this material, as the tools and pendants along with their applied motifs are a result of what is in between these binary positions.

Page generated in 0.0464 seconds