• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • Tagged with
  • 63
  • 63
  • 63
  • 63
  • 61
  • 61
  • 53
  • 48
  • 35
  • 20
  • 19
  • 15
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Dura??o e seq??ncia de ativa??o muscular durante atividades de vida di?ria em indiv?duos dentados e edentados

Cosme, D?cia Caldas 29 June 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:41Z (GMT). No. of bitstreams: 1 392442.pdf: 2886386 bytes, checksum: cb489781ad921d3ccb0830760710c35c (MD5) Previous issue date: 2007-06-29 / Estudos recentes t?m associado a sa?de bucal, avaliada atrav?s de estabilidade e suporte oclusal, com performance f?sica e atividade muscular em diferentes faixas et?rias. Os objetivos deste trabalho foram comparar a dura??o e a seq??ncia de ativa??o dos mm. mastigat?rios (mm. temporal e masseter), mm. posturais de cabe?a e pesco?o (mm. esternocleidomast?ideo e trap?zio), do tronco (mm. reto abdominal e paravertebrais) e de for?a das extremidades inferiores (mm. reto femoral e gastrocn?mio medial), durante simula??o de atividades de vida di?ria (AVDs) em dois grupos de mulheres: Grupo 1 - usu?rias de pr?teses totais (PTs) bimaxilares (n=10) e Grupo 2 - dentadas jovens (n=10). Foram coletadas vari?veis demogr?ficas, antropom?tricas e de sa?de geral. A atividade eletromiogr?fica (EMG) foi registrada durante os testes da cadeira (levantar/sentar), da cama (levantar/deitar) e das sacolas (levantar/abaixar), sendo computados os valores de dura??o de ativa??o muscular, medidos em ms, e a seq??ncia de ativa??o muscular a partir do tempo de lat?ncia. Em rela??o ? dura??o de ativa??o muscular, houve diferen?a significativa apenas para o teste da cadeira comparando-se as condi??es com e sem PTs no grupo 1, sendo que os mm. masseter, temporal e esternocleidomast?ideo apresentaram maior dura??o de ativa??o com PTs no movimento de levantar. Na compara??o entre os grupos 1 (com PTs) e 2, o grupo 1 teve maior dura??o de ativa??o dos mm. esternocleidomast?ideo e trap?zio no movimento de levantar da cama. No teste das sacolas, os mm. esternocleidomast?ideo e gastrocn?mio apresentaram maior dura??o de ativa??o para o grupo 2, e o reto femoral para o grupo 1. Em rela??o ? seq??ncia de ativa??o muscular, no teste da cadeira, os mm. masseter, esternocleidomast?ideo e trap?zio apresentaram altera??o significativa com a remo??o do suporte oclusal no grupo 1, assim como tend?ncia de antecipa??o para os mm. reto femoral e gastrocn?mio. Para o teste da cama, houve efeito estatisticamente significativo do suporte oclusal na seq??ncia de ativa??o para o m. gastrocn?mio no levantar e m. reto abdominal no deitar, que ativaram antes sem as PTs. Para o teste das sacolas, houve diferen?a significativa para os mm. esternocleidomast?ideo e trap?zio em fun??o do suporte oclusal no movimento de abaixar. Comparando os grupos 1 e 2, houve altera??o significativa da seq??ncia de ativa??o para os mm. mastigat?rios, posturais de cabe?a e pesco?o, posturais do tronco e de for?a nos tr?s testes. Foi observada antecipa??o dos mm. paravertebrais, reto abdominal e gastrocn?mio no grupo de dentadas jovens comparada ?s usu?rias de PTs. A avalia??o qualitativa dos gr?ficos de ativa??o muscular mostrou uma grande variabilidade intra e intersujeito durante os movimentos testados. De modo geral, os resultados sugerem que o suporte oclusal e a idade influenciaram a atividade EMG dos diversos grupos musculares durante os testes de simula??o de AVDs.
52

Avalia??o cl?nica de pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner

Ara?jo, Pryscyla Pascally Targino 19 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:43:51Z (GMT). No. of bitstreams: 1 PryscylaPTA_DISSERT.pdf: 1471076 bytes, checksum: 63eee78ee148fad88e300caf30aa4256 (MD5) Previous issue date: 2012-12-19 / This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study / Este trabalho se prop?s a avaliar pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner, considerando a sobreviv?ncia dos implantes convencionais e zigom?ticos, a sa?de do seio maxilar e o n?vel de satisfa??o dos pacientes em rela??o ? reabilita??o oral. Foram avaliados 28 pacientes, onde 14 haviam recebido implantes zigom?ticos e convencionais, encontrando-se reabilitados com pr?teses totais fixas implantossuportadas (grupo 1) e 14 foram reabilitados somente com implantes convencionais e pr?teses totais fixas implantossuportadas (grupo 2). O estudo teve quatro fases, representadas pela avalia??o radiogr?fica dos implantes (fase I), avalia??o cl?nica (fase II), avalia??o da sa?de do seio maxilar (fase III) e aplica??o de um question?rio para mensurar a satisfa??o da reabilita??o com pr?tese fixa total implanto-suportada (fase IV). O grupo 2 s? foi submetido a fase IV, enquanto o grupo 1 participou de todas as etapas. Foram realizadas an?lises descritivas e estat?sticas, tendo, esta ?ltima, utilizado o test t para amostras independentes na avalia??o da fase IV. Os resultados demonstraram que a t?cnica de Stella & Warner mostrou-se efetiva, permitindo um elevado ?ndice de sobreviv?ncia dos implantes convencionais e zigom?ticos (100%), considerando um per?odo m?nimo de acompanhamento de 15 meses e m?ximo de 53 meses ap?s reabilita??o prot?tica. N?o foram encontradas altera??es patol?gicas nos tecidos periimplantares dos implantes convencionais e zigom?ticos analisados. Os achados radiogr?ficos mostraram n?veis ?sseos satisfat?rios nos implantes convencionais das reabilita??es orais com fixa??es zigom?ticas e um bom posicionamento do ?pice dos implantes zigom?ticos em rela??o ao osso zigom?tico. A presen?a do implante zigom?tico n?o provocou sinusopatias e o teste t demonstrou um ?ndice de satisfa??o inferior no grupo 1 quando comparado ao grupo 2. A coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner mostrou ser uma t?cnica previs?vel, com alto ?ndice de sobreviv?ncia em pacientes com maxilas atr?ficas, sendo necess?rio um acompanhamento por longo prazo para confirmar os achados iniciais desse estudo
53

Efeito da distribui??o ?ntero-posterior de implantes em pr?teses tipo overdentures : an?lise de elemento finito com modelo tridimensional

Broilo, Josu? Ricardo 06 March 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:20Z (GMT). No. of bitstreams: 1 408026.pdf: 2274366 bytes, checksum: c74123e225ad17adb904436b3651eaa4 (MD5) Previous issue date: 2008-03-06 / O objetivo deste trabalho foi avaliar, atrav?s de an?lise por elementos finitos, o comportamento biomec?nico de uma t?cnica alternativa de distribui??o de implantes em overdentures e dois sistemas de attachments: Locator? (3i Implant Innovation) e Dal-Ro? (3i Implant Innovation). Foram estudadas as tens?es geradas em modelos tridimensionais variando-se a localiza??o ?nteroposterior dos implantes osseointegrados em uma mand?bula ed?ntula e o tipo de attachment. Foram gerados modelos tridimensionais de uma mand?bula ed?ntula a partir das imagens de tomografia computadorizada helicoidal, e dos attachments, da pr?tese total, da placa resiliente e dos implantes atrav?s de digitaliza??o a laser em tr?s planos. Foram constru?dos quatro modelos: modelo padr?o (MP) 1 - implantes inseridos na regi?o dos caninos (dentes 43 e 33) e sistema Locator; MP 2 implantes inseridos como no modelo 1 e sistema Dal-Ro, modelo alternativo (MA) 3 implantes inseridos na regi?o dos dentes 44 e 34 e sistema Locator, (MA) 4 implantes inseridos como no modelo 3 e sistema Dal- Ro. Os modelos geom?tricos foram importados para o programa ANSYS 10.0, no qual foi gerada a malha de elementos finitos. Uma carga vertical est?tica de 100 N foi aplicada sobre uma simula??o de bolo alimentar, na regi?o de primeiro molar inferior direito, sendo analisadas e comparadas as distribui??es de tens?o de Von Mises geradas. A maior ?rea de distribui??o de tens?o no rebordo alveolar ocorreu nos modelos padr?o com attachments Locator? e Dal Ro?, sendo o melhor desempenho conferido aos modelos alternativos em fun??o da menor ?rea de distribui??o das tens?es. Os modelos com attachments Dal Ro? mostraram-se mais favor?veis do ponto de vista biomec?nico em rela??o aos attachments Locator?, pois o padr?o de distribui??o de tens?es foi mais uniforme ao longo do seu eixo, apesar da magnitude dessas tens?es serem maiores nestes modelos. Pode-se concluir que a distribui??o ?ntero-posterior para os MAs com attachments Locator? e Dal Ro? apresentaram um comportamento biomec?nico vi?vel.
54

Passividade na interface pr?tese/pilar intermedi?rio de infraestrutura implantossuportadas confeccionadas pela tecnologia CAD/CAM e m?todo convencional

Ara?jo, Gabriela Monteiro de 28 August 2014 (has links)
Made available in DSpace on 2014-12-17T15:43:56Z (GMT). No. of bitstreams: 1 GabrielaMA_DISSERT.pdf: 606059 bytes, checksum: cac128da2c04d2e2044a79faa5d2f38c (MD5) Previous issue date: 2014-08-28 / The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250?). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ? 13.45 μm) and CoCrci the worst (187.55 ? 103.63 μm), Zircad presented an intermediate value (103.81 ? 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ? 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques / O objetivo desta pesquisa foi avaliar a passividade e a tens?o induzida em infraestruturas parafusadas sobre pilares, confeccionadas por tecnologia CAD / CAM, e comparar com infraestruturas fabricadas por fundi??o convencional. Com a utiliza??o da tecnologia de CAD / CAM, 4 infraestruturas de 3 elementos foram confeccionadas em zirc?nia (ZirCAD) e 4 em cobalto-cromo (CoCrcad). Para o grupo controle foram utilizadas 4 infraestruturas em cobalto- cromo, confeccionadas por fundi??o em monobloco (CoCrci), totalizando 12 infraestruturas. Para avaliar a passividade, as infraestruturas foram instaladas sobre os pilares. Uma extremidade foi apertada e a diferen?a vertical entre a infraestrutura e o pilar prot?tico na outra extremidade foi medida com microscopia eletr?nica de varredura (250 ?). A tens?o m?dia gerada aos implantes foi analisada por meio do teste de fotoelasticidade. An?lise de Vari?ncia (ANOVA) foi aplicada a fim de comparar as m?dias entre os grupos para a passividade e ?rea de tens?o. Com isso, para a compara??o dois a dois entre os grupos, o teste T foi utilizado para a avalia??o da passividade e teste Tukey para a ?rea de tens?o. Foi observada uma diferen?a significativa (p = 0,000) na passividade entre os grupos controle (CoCrci) e demais amostras (CoCrcad e CoCrci). CoCrcad exibiu o menor valor de passividade (48,76 ? 13:45 μm) e CoCrci o maior (187,55 ? 103,63 μm), Zircad apresentou um valor intermedi?rio (103.81 ? 43.15 μm). Quando comparado com os outros grupos, CoCrci apresentou a maior m?dia tens?o ao redor dos implantes (17,19 ? 7,22 kPa). Concluiuse que as pe?as confeccionadas por CAD/CAM em zirc?nia apresentaram uma maior desadapta??o marginal vertical do que aquelas fabricadas em cobalto-cromo com a mesma metodologia, por?m, a tens?o gerada aos implantes foi semelhante. Entretanto, a tecnologia CAD/CAM foi mais precisa do que a t?cnica convencional de fabrica??o de infraestruturas parafusadas sobre pilares prot?ticos, tanto em rela??o ao desajuste marginal, quanto ? tens?o gerada aos implantes
55

Avalia??o da qualidade de vida e do processo de tomada de decis?o na indica??o e uso de pr?tese dent?ria em idosos

Nocchi, Palmizio 15 October 2008 (has links)
Made available in DSpace on 2015-04-14T13:53:22Z (GMT). No. of bitstreams: 1 407892.pdf: 239416 bytes, checksum: b242e04901c182fa355648458cf4ca4d (MD5) Previous issue date: 2008-10-15 / Introdu??o: A qualidade de vida nos idosos est? diretamente relacionada ao estado de sa?de geral, bem como, ao estado de sa?de bucal. Qualidade de vida associada ? sa?de bucal tem sido definida como uma avalia??o multidimensional mais detalhada da reabilita??o prot?tica. Objetivo: avaliar a qualidade de vida, a capacidade de tomada de decis?o e a percep??o de coer??o em idosos usu?rios de pr?tese dent?ria. Metodologia: estudo transversal, observacional, anal?tico n?o- probabil?stico. Para tanto, 38 idosos foram selecionados do Servi?o de Atendimento Odontol?gico da PUCRS e cl?nicas privadas. Os instrumentos utilizados para a an?lise foram os seguintes: Escala de Percep??o de Coer??o em Assist?ncia, Instrumento Desenvolvimento Psicol?gico-moral, WHOQOL OLD e WHOQOL Bref. Resultados: Dos 38 idosos inclu?dos no estudo, 16 eram do g?nero masculino e 22 do g?nero feminino. A idade m?dia dos homens foi de 75,44+8,82 anos e das mulheres foi de 74,95+7,15 anos. Com rela??o ? percep??o de coer??o, as mulheres apresentaram alguma percep??o de coer??o, por?m n?o se verificou diferen?a significativa entre os dois g?neros (p=0,950). Observou-se uma maior freq??ncia dos homens na fase aut?noma, enquanto a maioria das mulheres encontrou-se na fase conscienciosa. Os valores m?dios deste teste tamb?m foram similares entre o g?nero (homens= 5,0?0,7 e mulheres= 4,6?0,9) (p=0,175). 75,0% das mulheres disseram n?o controlar, controlar pouco ou mais ou menos o seu futuro enquanto que somente 43,8% dos homens deram esta resposta (0,05). A pontua??o m?dia geral do WHOQOL-OLD foi de 34,1?5,6 para os homens e 32,2?6,9 para as mulheres (p=0,384). No WHOQOL-BREF os valores m?dios dos idosos foram de 94,2?11,0 para os homens e 89,5?18,1 para as mulheres (p=0,360). N?o se verificou associa??o entre qualidade de vida, percep??o de coer??o e tomada de decis?o em idosos com pr?tese dent?ria. Conclus?o: o problema dent?rio que levou a coloca??o de pr?tese nos idosos dessa amostra (eliminado outros fatores) n?o contribuiu para que os mesmos tivessem uma qualidade de vida ruim.
56

Avalia??o da rela??o entre perda ?ssea periimplantar e carga oclusal em implantes dent?rios associados ? pr?teses fixas implantosuportadas

?vila, Roberta Alencastro 20 January 2017 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-06-30T17:56:18Z No. of bitstreams: 1 DIS_ROBERTA_ALENCASTRO_AVILA_PARCIAL.pdf: 118749 bytes, checksum: dc5aeca744ebbdf64a56379812249ac5 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-06-30T17:56:27Z (GMT) No. of bitstreams: 1 DIS_ROBERTA_ALENCASTRO_AVILA_PARCIAL.pdf: 118749 bytes, checksum: dc5aeca744ebbdf64a56379812249ac5 (MD5) / Made available in DSpace on 2017-06-30T17:56:37Z (GMT). No. of bitstreams: 1 DIS_ROBERTA_ALENCASTRO_AVILA_PARCIAL.pdf: 118749 bytes, checksum: dc5aeca744ebbdf64a56379812249ac5 (MD5) Previous issue date: 2017-01-20 / Introduction: The objective of this work was through a prospective cohort analysis evaluate possible correlations between periimplantar bone loss of lower fixed implants (PTFIs) and their respective distribution of bilateral occlusal contacts, maximum bite force (FMM), area occlusal contacts of left and right lateral movements, their relation with the antagonist arch and the presence or absence of provisional fixed prosthesis. Materials and Methods: This convenience sample consisted of 20 (twenty) patients with lower PTFIs who were followed for one year, after the installation of the prosthesis. In the two data collections the FMM measurement was performed, the occlusal contacts distribution was measured through the T-Scan III device and a Cone Beam computed tomography was ordered to evaluate the periimplant bone loss. For the measurement of bone loss, a comparison was made between the initial and second moments. After this process the results of periimplant bone loss were correlated and compared with the other data obtained. The statistical analysis performed to evaluate bone loss of implants was the Friedman test and Wilcoxon test, Mann-Whitney comparisons test, the Spearman correlations test and Student's T-test. Results: The main results were: 1) the implants do not differentiate in relation to periimplant bone loss; 2) there was no significant correlation of bone loss with FMM, right and left laterality and the distribution of contacts in maximum intercuspal position; 3) in comparison between bone loss of patients with full dentures and partially edentulous, they showed no statistically significant difference, as well as in patients who received provisional full prosthesis and those who did not receive. Conclusion: Bone loss appears to occur similarly between all implants, sides, and regions. FMM, R and L laterality, MIH contact distribution, and the antagonist arcade do not appear to interfere with periimplant bone remodeling. The preliminary results of this study suggest that there is no need for provisioning in inferior restorations, since there were no differences in bone loss between patients who received and did not receive fixed provisional. / Introdu??o: O objetivo deste trabalho foi atrav?s de uma an?lise tipo coorte prospectivo, avaliar as poss?veis rela??es existentes entre a perda ?ssea periimplantar de pr?teses totais fixas implantossuportadas inferiores (PTFIs) e sua respectiva distribui??o de contatos oclusais bilaterias, for?a m?xima de mordida (FMM), ?rea de contatos oclusais nos movimentos de lateralidade esquerda e direita, sua rela??o com arcada antagonista e presen?a ou n?o de pr?tese fixa provis?ria. Materiais e M?todos: A amostra de conveni?ncia foi constitu?da por 20 pacientes portadores PTFIs inferiores, e foram acompanhados por um per?odo de um ano, ap?s a instala??o da pr?tese. Nas duas coletas de dados foi realizada a medi??o da FMM, medi??o da distribui??o dos contatos oclusais atrav?s do aparelho T-Scan III e solicitado uma tomografia computadorizada Cone Beam para avalia??o da perda ?ssea periimplantar. Para mensura??o da perda ?ssea, foi realizada a compara??o entre as tomadas iniciais e no segundo momento. Ap?s, os resultados de perda ?ssea periimplantar foram correlacionados e comparados com os demais dados obtidos. A an?lise estat?stica realizada para avaliar perda ?ssea dos implantes, lados e regi?es foi o teste de Friedman e teste de Wilcoxon, para compara??es teste de Mann-Whitney e para as correla??es teste de Spearman e teste T de Student. Resultados: Os principais resultados foram: 1) os implantes n?o se diferenciam em rela??o a perda ?ssea periimplantar; 2) n?o houve correla??o significativa de perda ?ssea com FMM, lateralidade D e E e a distribui??o de contatos em MIH; 3) na compara??o entre perda ?ssea de pacientes com antagonista PT e parcialmente ed?ntulos, n?o mostrou diferen?a estatisticamente significativa, assim como em pacientes que receberam protocolo provis?rio e os que n?o receberam. Conclus?o: A perda ?ssea parece ocorrer de forma semelhante entre todos os implantes, lados e regi?es. A FMM, a lateralidade D e E, a distribui??o de contatos em MIH e a arcada antagonista n?o parecem interferir na remodela??o ?ssea periimplantar. Os resultados preliminares deste estudo sugerem que n?o h? necessidade de provisionaliza??o em protocolos inferiores, visto que n?o houve diferen?as de perda ?ssea entre os pacientes que receberam e n?o receberam provis?rio fixo.
57

Avalia??o da influ?ncia do uso de pr?teses totais superiores ao dormir na qualidade e dist?rbios do sono, bruxismo, disfun??es temporomandibulares e dor orofacial

Mattia, Paulo Roberto Castro 30 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-06-30T17:23:31Z No. of bitstreams: 1 TES_PAULO_ROBERTO_CASTRO_MATTIA_PARCIAL.pdf: 360391 bytes, checksum: 09001741931b57c50fd6b7240b6295d7 (MD5) / Made available in DSpace on 2016-06-30T17:23:31Z (GMT). No. of bitstreams: 1 TES_PAULO_ROBERTO_CASTRO_MATTIA_PARCIAL.pdf: 360391 bytes, checksum: 09001741931b57c50fd6b7240b6295d7 (MD5) Previous issue date: 2016-03-30 / The use of complete dentures during sleep is still under debate. The use is indicated or not quite empirically, based only on controlling stomatitis caused by fungal infections. The objective was to evaluate the impact of maxillary edentulism and consequent use of complete dentures during sleep in the quality of life, sleep quality, sleep bruxism, temporomandibular dysfunction, level of sleepiness and apnea index in patients. For this, 20 patients from the researcher?s private practice were selected, 90% women and 10% men, average age of 61 years. The subjects must have complete upper dentures and fixed lower implant-supported dentures made in a standardized way. Patients were submitted to anamnesis, and validated questionnaires of sleep quality (PSQI-BR / The Pittsburgh Sleep Quality Index BR; SAQ / Sleep Assessment Questionnaire), sleepiness (ESS-BR / Epworth Sleepiness Scale BR, bruxism (QABN / Questionnaire nocturnal bruxism evaluation) and temporomandibular disorders (RDC / TMD axis I / Research Diagnostic Criteria for temporomandibular Disorders). The sleep bruxism was also measured with the validated myographic device BiteStrip. After sleeping one night with cardiorespiratory portable type 3 monitor ApneaLink? (ResMed, Australia) using the upper denture at home, a washout period of at least 7 days was respected and all questionnaires were repeated. Then, the patient slept again with the portable monitor and without the upper denture. The RDC / TMD axis I detected 95% of absence of muscle disorders in both tests. There was no significant difference in the SAQ global score between before and after according to the Wilcoxon signed rank test (2tail). PSQI-BR and ESS-BR also showed no significant differences between the two tests, except for the component number 5 of the PSQI-BR. Regarding sleep bruxism, the QABN and the myographic device BiteStrip also showed no significant differences between measurements with and without the use of dentures. Regarding cardiorespiratory monitoring in any of the indexes there was no significant difference between the before and after moments. The indexes measured were respiratory disturbance index (RDI), baseline oxygen saturation (%), average (%) and minimum (%), and oxygen saturation time < 90%, oxygen saturation percentage < 90% and the Oxygen desaturation index (ODI). It was noticed in RDI a difference in absolute numbers that could translate into statistically significant results if the sample were larger. Finally, no significant differences were recorded between before and after, neither in the questionnaires nor in the myographic device and the cardiorespiratory monitoring. Thus, further studies are needed in order to establish a more exact relationship between the use of complete dentures and their influence on sleep quality, sleepiness, temporomandibular disorders (TMD) and sleep bruxism. / A utiliza??o de pr?teses totais durante o sono ? ainda alvo de discuss?o. O uso ? indicado ou n?o de maneira bastante emp?rica, baseando-se apenas no controle de estomatites causadas principalmente por infec??es f?ngicas. O objetivo foi avaliar o impacto do edentulismo superior e consequente uso de pr?teses totais durante o sono na qualidade de vida, qualidade de sono, bruxismo do sono, disfun??o temporomandibular, n?vel de sonol?ncia e ?ndice de apneia em pacientes. Para isso, foram selecionados 20 pacientes da cl?nica particular do pesquisador, 90% mulheres e 10% homens, com idade m?dia de 61 anos. Os indiv?duos apresentaram Pr?teses Totais Convencionais superiores e Pr?teses Totais fixas Implantossuportadas inferiores adequadas e confeccionadas de maneira padronizada. Os pacientes foram submetidos ? anamnese, e a question?rios validados de qualidade de sono (PSQI-BR/The Pittsburgh Sleep Quality Index BR; SAQ/Sleep Assessment Questionnaire), sonol?ncia (ESS-BR/Epworth Sleepiness Scale BR, bruxismo (QABN/Question?rio de Avalia??o de Bruxismo Noturno) e disfun??o temporomandibular (RDC/TMD eixo I/Research Diagnostic Criteria for Temporomandibular Disorders). O bruxismo noturno tamb?m foi aferido com o dispositivo miogr?fico validado BiteStrip. Ap?s, dormiram uma noite com monitor cardiorrespirat?rio port?til tipo 3 ApneaLink? (ResMed, Australia) utilizando a pr?tese total superior em seu domic?lio. Respeitou-se um per?odo de washout de no m?nimo 7 dias para que todos os question?rios fossem repetidos e o paciente dormisse novamente com o monitor port?til e sem a pr?tese total. O RDC/TMD eixo I detectou 95% de aus?ncia de desordens musculares em ambos os exames. N?o houve diferen?a significativa no escore global do SAQ entre o antes e depois de acordo com o Wilcoxon signed ranks test (2tail). PSQI-BR e ESS-BR tamb?m n?o apresentaram diferen?as significativas entre os dois exames, com exce??o do componente 5 do PSQI-BR. Em rela??o ao bruxismo do sono, o QABN e o dispositivo miogr?fico BiteStrip tamb?m n?o apresentaram diferen?as significativas entre as medi??es com ou sem a utiliza??o da dentadura. Em rela??o ? monitora??o cardiorrespirat?ria, em nenhuma dos ?ndices houve diferen?a significativa entre o antes e o depois. As medi??es foram de ?ndice de Dist?rbios Respirat?rios (IDR), Satura??o de oxig?nio basal (%), m?dia (%) e m?nima (%), al?m de Tempo de satura??o de oxig?nio < 90%, porcentagem de satura??o de oxig?nio < 90% e o ?ndice de Dessatura??o de Oxig?nio (IDO). Percebeu-se no IDR uma diferen?a em n?meros absolutos que poderia se traduzir em estatisticamente significativa se a amostra fosse maior. Por fim, n?o foram registradas diferen?as significativas entre o antes e o depois, tanto nos question?rios quanto no dispositivo miogr?fico e monitoriza??o cardiorrespirat?ria port?til. Assim, mais estudos s?o necess?rios para que se estabele?a uma rela??o mais exata entre o uso de dentaduras completas e sua influ?ncia na qualidade de sono, sonol?ncia, desordens temporomandibulares (DTM) e bruxismo do sono.
58

Influ?ncia do laser de baixa pot?ncia (GaAIAs - [Comprimento de onda] 830nm) na forma??o ?ssea em implantes lisos e texturizados : uma an?lise histomorfom?trica

Torres, Marco Ant?nio Rambo Os?rio 15 January 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:15Z (GMT). No. of bitstreams: 1 399356.pdf: 4105847 bytes, checksum: 0c59a09fa1073f779a885d9635fec74e (MD5) Previous issue date: 2008-01-15 / Este trabalho in vivo controlado e com cegamento avaliou post mortem, atrav?s da an?lise histomorfom?trica, a influ?ncia do laser de baixa pot?ncia na forma??o ?ssea em implantes lisos e texturizados inseridos em t?bias de coelhos, submetidos ou n?o ? irradia??o com laser de GaAlAs com comprimento de onda de 830nm, de forma cont?nua por 10 segundos, com pot?ncia de 100mW. Para tanto foram utilizados seis coelhos da ra?a Nova Zel?ndia, distribu?dos igualmente de forma aleat?ria em grupo irradiado e grupo controle, onde cada coelho recebeu quatro implantes, sendo dois lisos na t?bia direita e dois texturizados na t?bia esquerda. Os animais do grupo experimental receberam irradia??o transcutaneamente em tr?s pontos ao redor dos implantes, durante 15 dias a cada 48 horas, sendo a primeira aplica??o no dia da cirurgia, com total de oito dias de irradia??o e dose total de 24J/cm2 em cada t?bia (3 pontos x 1J x 8 aplica??es = 24J). Os animais do grupo controle foram submetidos ? mesma rotina dos animais irradiados, por?m com equipamento laser desligado. Ap?s 30 dias todos os animais sofreram eutan?sia para obten??o de l?minas histol?gicas coradas com azul de toluidina a partir de cortes das t?bias com os implantes inseridos numa espessura final de 10 a 19&#956;m. Para avalia??o do percentual de contato osso-implante os dois cortes mais centrais de cada amostra, de forma cegada, foram fotomicrografados em microsc?pio ?ptico e analisados atrav?s de um programa digital de processamento de imagens. As m?dias obtidas a partir dos dois cortes de cada implante, ap?s desfeito o cegamento, foram comparadas de forma geral e dentro dos grupos utilizando-se o teste t-student. N?o houve diferen?a estatisticamente significativa (p>0,05) no percentual de contato osso-implante entre os grupos laser (77,048% ? 10,173) e controle (69,516% ? 19,284) de forma geral, nem entre os subgrupos texturizado com laser (81,530% ? 10,155), texturizado controle (72,190% ? 16,778), liso com laser (72,565% ? 8,737) e liso controle (66,842% ? 22,791). Estes resultados sugerem que o laser de baixa pot?ncia, com o protocolo de irradia??o utilizado neste modelo animal, n?o contribuiu significativamente para o aumento do percentual de contato osso-implante. N?o obstante, o osso novo formado submetido ? irradia??o com laser de GaAlAs durante o per?odo de ossoeintegra??o, parece apresentar uma maior vasculariza??o e organiza??o lamelar que o grupo controle, sugerindo uma maior matura??o. Por?m, s?o necess?rias novas pesquisas de modo a preencher as lacunas ainda existentes quanto ao entendimento dos mecanismos biol?gicos da a??o do laser de baixa pot?ncia na media??o dos processos necess?rios ? osseointegra??o de implantes de tit?nio, bem como dos par?metros dosim?tricos para obten??o da bioestimula??o ?ssea.
59

Influ?ncia do acabamento de preparos para coroas totais com microsc?pio operat?rio na adapta??o marginal de restaura??es em cer?mica tipo CAD-CAM

Oliveira, Jos? Pedro Peixoto de 16 January 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:16Z (GMT). No. of bitstreams: 1 399743.pdf: 674310 bytes, checksum: 694cbc44bc682f21bed71e69a6f99e90 (MD5) Previous issue date: 2008-01-16 / Este estudo teve o objetivo de avaliar a adapta??o de infra-estruturas de cer?mica Lava (3M/ESPE) com tr?s diferentes tipos de acabamento em preparos para coroa total. Trinta pr?-molares humanos, extra?dos por raz?es terap?uticas, foram fixados em blocos de resina acr?lica e divididos aleatoriamente em tr?s grupos (n=10) de acordo com o procedimento para realizar os preparos: grupo 1 - ponta diamantada; Grupo 2 - ponta diamantada e broca multi-laminada; Grupo 3 - ponta diamantada e broca multi-laminada, sendo este ?ltimo instrumento com o uso do microsc?pio operat?rio em aumento de 12,5 vezes. Os preparos foram moldados com silicone por adi??o e os modelos obtidos em gesso especial tipo IV. Os modelos foram enviados para o laborat?rio da 3M/ESPE, o qual confeccionou os casquetes de cer?mica Lava. As infra-estruturas foram cimentadas nos dentes preparados com RelyX Unicem, sendo ent?o inclu?dos em blocos de resina acr?lica e cortados em dois planos: m?sio-distal e vest?bulo-lingual. Desta forma, obteve-se quatro fragmentos, sendo que cada fragmento forneceu duas regi?es para observar a discrep?ncia das margens. Por meio de lupa estereosc?pica, acoplada a uma c?mera de v?deo, foram obtidas imagens digitais da regi?o das margens em aumento de 70 vezes. As medidas de adapta??o marginal foram realizadas no programa Image Tool. De acordo com ANOVA e teste de Tukey (&#945;=0,05), n?o houve diferen?a estat?stica entre os Grupo 1 (88,601 &#956;m) e Grupo 2 (90,946 &#956;m). A menor m?dia foi obtida para o Grupo 3 (58,497 &#956;m), diferindo estatisticamente dos outros dois grupos. P?de-se concluir que o emprego do microsc?pio operat?rio favoreceu a melhor adapta??o marginal nos casquetes de cer?mica Lava.
60

Estudo da viabilidade do processo de reciclagem do material descartado do sistema Zirkonzanh? de produ??o de pr?teses dent?rias

Silva, Yankel Bruno Fontes 17 March 2014 (has links)
Made available in DSpace on 2014-12-17T14:07:21Z (GMT). No. of bitstreams: 1 YankelBFS_TESE.pdf: 4090438 bytes, checksum: fb7a52b044d1b89e50309a0eea67270d (MD5) Previous issue date: 2014-03-17 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / At present, the material of choice for performing aesthetic dental prosthetic work is in the ceramic. Among them, the ceramic base of stabilized zirconia with 3% yttria (3Y - TZP) stand out for having excellent physical and mechanical properties. During the machining of blocks of zirconia in the laboratory to prepare the various types of prostheses, much of the material is given off in the form of powder, which is subsequently discarded. The waste of this material results in financial loss, reflecting higher final cost treatment for patients, as well as damage to the environment, thanks to the processes involved in the manufacture and disposal of the ceramic. This research, pioneered the recycling of zirconium oxide powder obtained during milling of dental crowns and bridges, we highlight the social and environmental aspects and aims to establish a protocol for the reuse of waste (powder of zirconia Zirkonzahn? system) discarded to obtain a new block of compacted zirconia to maintain the same mechanical and microstructural properties of commercial high-cost imported material. To compare with the commercial material, samples were uniaxially (20 MPa) and isostatically (100 MPa), and its mechanical and microstructural characterization was performed through tests of density, porosity, dilatometry, X-ray diffraction (XRD), hardness, fracture toughness, resistance to fracture electron microscopy (SEM) and analysis of grain size. The results observed in the samples were isostatically pressed similiares those obtained with samples from the commercial material demonstrating the viability of the process / Na atualidade, o material de escolha para execu??o de trabalhos prot?ticos est?ticos em odontologia ? o cer?mico. Dentre eles, as cer?micas a base de zirc?nia estabilizada com 3% de ?tria (3Y-TZP) se destacam por apresentarem excelentes propriedades f?sicas e mec?nicas. Durante a usinagem dos blocos de zirc?nia em laborat?rio para preparo dos diversos tipos de pr?tese, grande parte do material ? desprendida na forma de p?, que posteriormente ? descartado. O desperd?cio deste material resulta em preju?zo financeiro, refletindo em elevado custo final no tratamento para os pacientes, al?m de preju?zo para o meio ambiente, devido aos processos envolvidos na fabrica??o e descarte da cer?mica. Esta pesquisa, pioneira na reciclagem do p? de ?xido de zirc?nia obtido durante a fresagem de coroas e pontes dent?rias, destaca-se nos aspectos social e ambiental e tem como objetivo, estabelecer um protocolo de reaproveitamento de res?duos (p? de zirc?nia do sistema Zirkonzahn?) descartados para a obten??o de um novo bloco de zirc?nia compactado que mantenha as mesmas propriedades mec?nicas e microestruturais do material comercial importado de alto custo. Para comparar com o material comercial, as amostras foram prensadas uniaxialmente (20 MPa) e isostaticamente (100 MPa), e sua caracteriza??o mec?nica e microestrutural foi realizada atrav?s dos ensaios de densidade, porosidade aparente, dilatometria, difra??o de raios X (DRX), microdureza, tenacidade a fratura, resist?ncia a fratura, microscopia eletr?nica de varredura (MEV) e an?lise de tamanho de gr?o. Os resultados constatados nas amostras prensadas isostaticamente foram similiares ?queles obtidos com as amostras do material comercial demostrando a viabilidade do processo

Page generated in 0.332 seconds