• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 107
  • 2
  • 1
  • Tagged with
  • 116
  • 116
  • 80
  • 69
  • 33
  • 23
  • 21
  • 19
  • 18
  • 17
  • 16
  • 14
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

"Tratamento dos tumores avançados da junção esofagogástrica por prótese auto-expansível com válvula anti-refluxo" / Antireflux valve self-expanding stent in the treatment of advanced gastroesophageal junction tumors

Spencer Cheng 14 December 2005 (has links)
Introdução: A colocação de próteses através da junção esofagogástrica propicia o refluxo gastroesofágico. Objetivos e métodos: Avaliação da paliação da disfagia, manifestações broncoaspirativas, parâmetros nutricionais e qualidade de vida de 30 pacientes com tumores avançados da junção esofagogástrica tratados por prótese metálica auto-expansível com válvula anti-refluxo de 2001 a 2004. Resultados: Melhora da disfagia e regurgitação. Sem alteração na tosse, eructação, pirose, parâmetros nutricionais e qualidade de vida. Conclusões: A prótese com válvula anti-refluxo foi eficaz na paliação da disfagia, impediu a ocorrência de manifestações broncoaspirativas, não interferiu nos parâmetros nutricionais e qualidade de vida / Background: Placement of stents through the gastroesophageal junction can cause reflux. Objective and methods: Evaluate dysphagia palliation, aspiration symptoms, nutritional parameters and quality of life in 30 patients treated for advanced gastroesophageal junction tumors with a self-expanding metal stent with anti-reflux valve from 2001 to 2004. Results: Dysphagia and regurgitation symptoms improved after placement. There was no changes in heartburn, cough, belching symptoms and also no improvement in nutritional parameters or quality of life. Conclusions: Antireflux valve self-expanding stents was effective in dysphagia palliation, avoided aspiration symptoms and did not affect nutritional parameters or quality of life
102

Fatores preditivos do insucesso clínico no tratamento das fístulas esofagorrespiratórias com prótese metálica autoexpansível em pacientes com câncer esofágico / Predictive factors of clinical failure of treatment of malignant esophageal fistula with self-expandable metallic stents

Ribeiro, Maria Sylvia Ierardi 11 September 2017 (has links)
INTRODUÇÃO: A fistula esofagorrespiratória é complicação temida do câncer esofágico avançado. A paliação com prótese metálica autoexpansível é método amplamente empregado, porém com resultados conflitantes. OBJETIVO: Identificar fatores associados ao insucesso clínico do tratamento da fístula esofagorrespiratória maligna com prótese metálica autoexpansível. MÉTODOS: Estudo retrospectivo através da análise de banco de dados elaborado de forma prospectiva de pacientes submetidos ao tratamento da fístula esofagorrespiratória maligna com prótese metálica autoexpansível entre janeiro de 2009 e fevereiro de 2016 em hospital terciário dedicado ao tratamento do câncer. Foram coletados dados quanto à: características demográficas, nível de albumina sérica, capacidade funcional do paciente, doença pulmonar infecciosa em atividade no momento da passagem da prótese, tratamentos oncológicos prévios, momento do diagnóstico da fístula, tamanho e localização do trajeto fistuloso. RESULTADOS: Um total de 71 pacientes foram incluídos no estudo (55 homens, idade média de 59 anos). Insucesso clínico ocorreu em 44.3% dos pacientes. ECOG 3 ou 4, desenvolvimento da fístula durante o tratamento do câncer esofágico e diâmetro da fístula >= 1 cm foram fatores preditivos do insucesso clínico. ECOG 3 ou 4, doença pulmonar infecciosa em atividade no momento da passagem da prótese e tratamento oncológico prévio com radioterapia foram fatores preditivos de menor sobrevida. O grau de disfagia melhorou significativamente 15 dias após a passagem da prótese. A taxa total de eventos adversos foi de 30%. Migração da prótese e a oclusão da mesma por crescimento tumoral nas extremidades da prótese foram os eventos adversos mais comumente observados. CONCLUSÃO: A prótese metálica autoexpansível é um método terapêutico efetivo para o tratamento da fístula esofagorrespiratória maligna, no entanto, ECOG 3 ou 4, desenvolvimento da fístula durante o tratamento do câncer esofágico e diâmetro da fístula >= 1cm foram fatores preditivos do insucesso clínico após a passagem da prótese / INTRODUCTION: Malignant esophagorespiratory fistula is a serious and life-threatening complication of esophageal cancer. Self-expandable metal stents placement is a well accepted palliative treatment, however, with conflicting results. OBJECTIVE: To identify risk factors associated with clinical failure after self-expandable metal stents placement for the treatment of malignant esophagorespiratory fistula. METHODS: This was a retrospective analysis of a prospectively maintained database used at a tertiary cancer hospital, with patients treated with SEMS placement for MERF between January 2009 and February 2016. The following variables were collected: patient demographics, serum albumin level, Eastern Cooperative Oncology Group (ECOG) performance status, pulmonary infection, previous oncologic treatment, moment of diagnosis of the malignant esophagorespiratory fistula, size and classification of the fistulous tract. RESULTS: A total of 71 patients (55 males, mean age 59 years) were considered for the final analysis. Clinical failure occurred in 44.3% of the patients. ECOG 3 or 4, fistula development during esophageal cancer treatment and fistula diameter >= 1cm were factors associated with increased risk of clinical failure. ECOG 3 or 4, pulmonary infection at the time of SEMS placement and prior radiation therapy were predictive factors associated with lower overall survival. Dysphagia scores improved significantly 15 days after stent insertion. The overall stent-related adverse events rate was 30%. Stent migration and occlusion due to tumor overgrowth were the most commonly seen adverse events. CONCLUSION: SEMS placement is a reasonable treatment option for MERF, however, ECOG 3 or 4, fistula development during esophageal cancer treatment or large fistula diameter may be independent predictors of clinical failure after stenting
103

Comparação entre prótese plástica e metálica na paliação endoscópica da obstrução maligna da via biliar: revisão sistemática e metanálise baseadas em estudos randomizados / Endoscopic stenting for inoperable malignant biliary obstruction: a systematic review and meta-analysis

Cheng Tao Pu, Leonardo Zorrón 12 April 2016 (has links)
INTRODUÇÃO: A prótese biliar endoscópica é aceita em todo o mundo como a primeira escolha de tratamento paliativo na obstrução biliar maligna. Atualmente ainda persistem dois tipos de materiais utilizados em sua confecção: plástico e metal. Consequentemente, muitas dúvidas surgem quanto a qual deles é o mais benéfico para o paciente. Esta revisão reúne as informações disponíveis da mais alta qualidade sobre estes dois tipos de prótese, fornecendo informações em relação à disfunção, complicação, taxas de reintervenção, custos, sobrevida e tempo de permeabilidade; e pretende ajudar a lidar com a prática clínica nos dias de hoje. OBJETIVO: Analisar, através de metanálise, os benefícios de dois tipos de próteses na obstrução biliar maligna inoperável. MÉTODOS: Uma revisão sistemática de ensaios clínicos randomizados (RCT) foi conduzida, com a última atualização em março de 2015, utilizando EMBASE, CINAHL (EBSCO), Medline, Lilacs / Centro (BVS), Scopus, o CAPES (Brasil), e literatura cinzenta. As informações dos estudos selecionados foram extraídas tendo em vista seis desfechos: primariamente disfunção, taxas de reintervenção e complicações; e, secundariamente, custos, sobrevivência e tempo de permeabilidade. Os dados sobre as características dos participantes do RCT, critérios de inclusão e exclusão e tipos de próteses também foram extraídos. Os vieses foram avaliados principalmente através da escala de Jadad. Esta metanálise foi registrada no banco de dados PROSPERO pelo número CRD42014015078. A análise do risco absoluto dos resultados foi realizada utilizando o software RevMan 5, calculando as diferenças de risco (RD) de variáveis dicotômicas e média das diferenças (MD) de variáveis contínuas. Os dados sobre a RD e MD para cada desfecho primário foram calculados utilizando o teste de Mantel-Haenszel e a inconsistência foi avaliada com o teste Qui-quadrado (Chi2) e o método de Higgins (I2). A análise de sensibilidade foi realizada com a retirada de estudos discrepantes e a utilização do efeito aleatório. O teste t de Student foi utilizado para a comparação das médias aritméticas ponderadas, em relação aos desfechos secundários. RESULTADOS: Inicialmente foram identificados 3660 estudos; 3539 foram excluídos por título ou resumo, enquanto 121 estudos foram totalmente avaliados e foram excluídos, principalmente por não comparar próteses metálicas (SEMS) e próteses plásticas (PS), levando a treze RCT selecionados e 1133 indivíduos metanálise. A média de idade foi de 69,5 anos, e o câncer mais comum foi de via biliar (proximal) e pancreático (distal). O diâmetro de SEMS mais utilizado foi de 10 mm (30 Fr) e o diâmetro de PS mais utilizado foi de 10 Fr. Na metanálise, SEMS tiveram menor disfunção global em comparação com PS (21,6% versus 46,8% p < 0,00001) e menos reintervenções (21,6% versus 56,6% p < 0,00001), sem diferença nas complicações (13,7% versus 15,9% p = 0,16). Na análise secundária, a taxa média de sobrevida foi maior no grupo SEMS (182 contra 150 dias - p < 0,0001), com um período maior de permeabilidade (250 contra 124 dias - p < 0,0001) e um custo semelhante por paciente, embora menor no grupo SEMS (4.193,98 contra 4.728,65 Euros - p < 0,0985). CONCLUSÃO: SEMS estão associados com menor disfunção, menores taxas de reintervenção, melhor sobrevida e maior tempo de permeabilidade. Complicações e custos não apresentaram diferença / INTRODUCTION: Endoscopic stenting is accepted worldwide as the first choice palliative treatment for malignant biliary obstruction. There are still two types of materials currently being used, which are plastic and metal. Therefore, many doubts are raised as to which one is the most beneficial to the patient. This review gathers the highest quality information available about these two types of stent, giving information in regards to dysfunction, complication, reintervention rates, costs, survival, and patency time; and intends to help handle clinical practice nowadays. OBJECTIVE: To analyze through meta-analyses the benefits of two types of stents in the inoperable malignant biliary obstruction. METHODS: A systematic review of randomized clinical trials (RCT) was conducted, with the last update on March 2015, using EMBASE, CINAHL (EBSCO), MEDLINE, LILACS/CENTRAL (BVS), SCOPUS, CAPES (Brazil), and gray literature. Information of the selected studies was extracted in sight of six outcomes: primarily regarding dysfunction, reintervention and complication rates; and secondarily costs, survival, and patency time. The data about characteristics of trial participants, inclusion and exclusion criteria and types of stents were also extracted. The biases were mainly assessed through the Jadad scale. This meta-analysis was registered in the PROSPERO database by the number CRD42014015078. The analysis of the absolute risk of the outcomes was performed using the software RevMan 5, by computing risk differences (RD) of dichotomous variables and mean differences (MD) of continuous variables. Data on RD and MD for each primary outcome were calculated using the Mantel-Haenszel test and inconsistency was qualified and reported in Chisquared (Chi2) and the Higgins method (I2). Sensitivity analysis was performed withdrawing discrepant studies and using random effect. Student\'s t-test was used for the comparison of weighted arithmetic means regarding secondary outcomes. RESULTS: Initial searching identified 3660 studies; 3539 were excluded through title or abstract, while 121 studies were fully assessed and were excluded mainly because they did not compare Self Expanding Metal Stents (SEMS) and Plastic Stents (PS), leading to thirteen RCT selected and 1133 subjects meta-analyzed. The mean age was 69.5 years old, that were affected mostly by bile duct (proximal) and pancreatic tumors (distal). The preferred SEMS diameter used was the 10 mm (30 Fr) and the preferred PS diameter used was 10 Fr. In the meta-analysis, SEMS had lower overall stent dysfunction compared to PS (21.6% versus 46.8% p < 0.00001) and fewer reintervention (21.6% versus 56.6% p < 0.00001), with no difference in complications (13.7% versus 15.9% p=0.16). In the secondary analysis, the mean survival rate was higher in the SEMS group (182 versus 150 days - p < 0.0001), with a higher patency period (250 versus 124 days - p < 0.0001) and a similar cost per patient, although lower in the SEMS group (4193.98 versus 4728.65 Euros - p < 0.0985). CONCLUSION: SEMS are associated with lower stent dysfunction, lower reintervention rates, better survival, and higher patency time. Complications and costs do not show difference
104

Avaliação da percepção auditiva da fala em pacientes submetidos ao reimplante coclear / Evaluation of auditory speech perception in patients submitted to cochlear reimplantation

Costa, Lucas Bevilacqua Alves da 18 July 2018 (has links)
Estudo retrospectivo, descritivo e longitudinal realizado na Seção de Implante Coclear, Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo (IC-CPA/HRAC/USP). O objetivo deste estudo foi caracterizar o desempenho da percepção auditiva da fala de indivíduos submetidos à cirurgia de reimplante coclear. No total de 1.323 indivíduos submetidos à cirurgia de implante coclear no período de 1990 a janeiro de 2016, consta o registro de 84 indivíduos submetidos à cirurgia de reimplante coclear, correspondendo a 6,3% do total. Deste total de 84, 68 indivíduos atenderam aos critérios de inclusão/exclusão da pesquisa e foram avaliados utilizando-se testes de percepção auditiva da fala, em três momentos: antes da segunda intervenção cirúrgica, após o reimplante e última avaliação de acompanhamento. As variáveis estudadas foram: a) motivo do reimplante coclear; b) etiologia da perda auditiva; c) idade na primeira cirurgia; d) tempo de uso do implante coclear antes do reimplante; e) tempo de recuperação do escore anterior à intervenção; f) tempo de uso atual; g) escore nos procedimentos de avaliação da percepção auditiva da fala, pré e pós-reimplante coclear. Na análise dos dados foi possível observar que a causa mais comum do reimplante foi a falha do dispositivo interno, seguido de razões médicas. Na avaliação auditiva da fala, um total de 61 (89,7%) recuperaram o desempenho observado antes do reimplante coclear e sete (10,3%), não alcançaram o mesmo desempenho. Constatou-se que as variáveis idade do primeiro Implante e tempo de uso do primeiro Implante Coclear, assim como tempo de reimplante, influenciaram nos resultados encontrados. A cirurgia de reimplante coclear é um procedimento viável, contudo a família e o paciente devem ser orientados quanto aos possíveis comprometimentos na percepção auditiva da fala / A retrospective, descriptive and longitudinal study performed in the Cochlear Implant Section, Audiological Research Center of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (IC-CPA / HRAC / USP). This study aimed at characterizing the auditory speech perception of individuals undergoing cochlear reimplantation surgery. Out of 1,323 individuals undergoing cochlear implant surgery from 1990 to January 2016, 84 (6.3%) subjects underwent cochlear reimplantation surgery. From this total of 84, 68 individuals met the inclusion / exclusion criteria of the study and were evaluated using auditory speech perception tests in three moments: before the second surgical intervention, after reimplantation and the last follow-up evaluation. The variables studied were: a) reason for cochlear reimplantation; b) etiology of hearing loss; c) age at first surgery; d) time cochlear implant use before reimplantation; e) recovery time from the previous intervention score; f) time of current use; g) score in the procedures of assessment of auditory speech perception before and after cochlear reimplantation. The data analysis showed that the most common cause of reimplantation was the failure of the internal device, followed by medical reasons. In the auditory speech evaluation, a total of 61 (89.7%) recovered performance before cochlear reimplantation, and seven (10.3%), did not reach the same performance. It was verified that the variables age at the first Implant and time using the first Cochlear Implant, as well as time of reimplantation, influenced the results. Cochlear replantation surgery is a viable procedure, however, the family and the patient should be advised on the possible compromising risks to the auditory speech perception
105

Correção de defeitos ventrais em ratos com próteses de polipropileno e politetrafluoroetileno expandido: análises histológica, biomecânica e da resposta aderencial / Repair of abdominal wall defects in rats with polypropylene and expanded polytetrafluoroethylene prostheses: histological, biomechanical and adhesion formation analysis

Amico, Enio Campos 30 March 2005 (has links)
Atualmente os defeitos herniários da parede abdominal são freqüentemente corrigidos com o uso de biomateriais. Embora utilizada com bons resultados há várias décadas, a prótese de Polipropileno (PP) tem implicado graves complicações decorrentes de aderências aos órgãos abdominais. A prótese de Politetrafluoroetileno expandido (PTFEe) tem reconhecidamente menor potencial aderencial; no entanto, dados obtidos de estudos biomecânicos deixam dúvida quanto a sua real eficiência na correção herniária. O objetivo do estudo foi comparar esses dois diferentes tipos de próteses na correção de defeitos ventrais produzidos em ratos Wistar, levando-se em consideração parâmetros histológicos, biomecânicos e da resposta aderencial. Para o estudo histológico um grupo de animais (n=21) foi submetido simultaneamente a implante subperitoneal de fragmentos de próteses de PP e PTFEe. Para o estudo comparativo da resposta biomecânica e aderencial entre as próteses, procedeu-se ao implante protético subperitoneal com PP (n=21) e PTFEe (n=21) para corrigir defeitos ventrais criados cirurgicamente envolvendo toda a espessura da parede abdominal dos animais. Para análise biomecânica, dois outros grupos de animais foram utilizados como controle: um grupo não submetido à cirurgia (n=15) e um grupo com correção de defeitos ventrais por meio de sutura (n=21). Todas as avaliações foram realizadas com 1, 2 e 4 semanas de pós-operatório e constituíram-se de: avaliação da resposta aderencial por meio de pesquisa da área de prótese aderida e incidência de aderência a órgãos, avaliação biomecânica por meio de ensaios de tração de tiras de parede abdominal e avaliação morfométrica do tecido inflamatório e das fibras colagênicas em cortes histológicos corados por Hematoxilina-eosina e pelo método da Picrossírius-polarização, respectivamente. Os resultados mostraram que: a fração de volume de tecido inflamatório no grupo PP na primeira, segunda e quarta semanas foi respectivamente: 20%, 9% e 4% enquanto no grupo PTFEe: 30%, 16% e 16%. Houve diferença estatística na segunda e quarta semanas. A fração de volume de colágeno fibrilar no grupo PP foi respectivamente: 65%, 71% e 77%, na primeira, segunda e quarta semanas. No grupo PTFEe os valores foram: 55%, 66% e 68%, na primeira, segunda e quarta semanas. Da mesma forma, houve diferença estatística na segunda e quarta semanas. Na análise semiquantitativa do grau de agregação de colágeno foi observado diferença estatística apenas primeira semana de pós-operatório a favor do PP (3,24 x 1,40 p=0,022). As próteses induziram valores semelhantes de área aderida na primeira (67,85%-PP x 71,42%- PTFEe), segunda (60,71%-PP x 60,71%-PTFEe) e quarta semanas de pós-operatório (46,42% PP x 42,85% PTFEe). Quanto à presença de aderência a órgãos abdominais houve diferença entre as próteses apenas na primeira semana a favor do PTFEe: enquanto 85,7% dos animais no grupo PP apresentaram aderências à órgãos, esse índice foi de apenas 28,5% no grupo PTFEe. Os valores de força máxima obtidos nos ensaios biomecânicos de tração com a prótese de PP foram na primeira, segunda e quarta semanas: 20,54 N, 21,62 N e 26,23 N. No grupo PTFEe os valores na primeira, segunda e quarta semanas foram: 16,92 N, 23,12 N e 25,41 N. Foi observada diferença estatística na primeira semana de pós-operatório. A comparação entre os implantes protéticos de PP e PTFEe nas condições da presente pesquisa permitiu concluir: 1) A estimativa de área aderida à prótese foi semelhante independentemente do material implantado; 2) Com 1 semana de pós-operatório, o implante de PP demonstrou-se mais resistente aos ensaios biomecânicos de tração o que se correlacionou a um maior grau de agregação das fibras colagênicas nos tecidos implantados; 3) Com 1 semana de pós-operatório, os implantes de PTFEe induziram aderências as órgãos abdominais em um menor número de animais; 4) Com 2 e 4 semanas de pós-operatório o implante de PP induziu a uma menor infiltração de tecido inflamatório e a um maior depósito de colágeno fibrilar / Nowadays, abdominal wall defects are frequently repaired with biomaterials. Although utilized with good results for several decades, polypropylene mesh (PP) has been implicated with serious complications due to adhesion to the abdominal organs. It has been reported that prostheses of expanded polytetrafluoroethylene (ePTFE) mesh exhibit less adhesion formation potential; however, data obtained by biomechanical studies leave doubt as to its real efficiency in hernia repair. The objective of the present study was to compare these two types of mesh in the correction of ventral defects created in Wistar rats, taking into account histological and biomechanical parameters and the adhesion response. For the histological study, a group of animals (n = 21) was submitted simultaneously to subperitoneal implantation of fragments of PP and ePTFE mesh. For the comparative study of the biomechanical and adhesion response between the prostheses, subperitoneal implantation with PP (n = 21) and ePTFE mesh (n = 21) was performed to repair surgically created abdominal defects, involving all layers of the abdominal wall. In the biomechanical analysis, two other groups of animals were used for the control: a group not submitted to surgery (n = 15) and a group with abdominal wall defects repaired with sutures (n = 21). At postoperative weeks 1, 2 and 4, the following evaluations were performed: study of the adhesion response by measuring the incidence of adherence to organs and area of adhered prosthesis; biomechanical test of abdominal wall strips; and morphometric study of the inflammatory tissue and collagenic fibers in sections stained with hematoxylin-eosin and by Picrosiriuspolarization technique. The results showed that: the inflammatory tissue volume in group PP at postoperative weeks 1, 2 and 4, respectively, was 20%, 9% and 4%; while in the group ePTFE the values were 30%, 16% and 16%. The difference was statistically significant in postoperative weeks 1 and 4. The collagen fibril volume in group PP was: 65%, 71% and 77%, in postoperative weeks 1, 2 and 4, respectively. In group ePTFE the values were: 55%, 66% and 68%. Likewise, there was a statistically significant difference in postoperative weeks 2 and 4. In the semi-quantitative analysis of the degree of collagen aggregation, a statistically significant difference was only observed in postoperative week 1, in favor of PP (3.24 x 1.40, p = 0.022). The prostheses induced similar values for adhered area in postoperative week 1 (67.85%-PP vs. 71.42%-ePTFE), week 2 (60.71%-PP vs. 60.71%-ePTFE) and week four (46.42% PP vs. 42.85% ePTFE). Regarding the presence of adherence to abdominal organs, there was only a statistically significant difference between the prostheses in week one, in favor of ePTFE. While 85.7% of the animals in group PP presented adherence to organs, this index was only 28.5% in group ePTFE. The maximum force obtained in the biomechanical tests with the PP mesh was 20.54 N, 21.62 N and 26.23 N, in postoperative weeks 1, 2 and 4, respectively. In group ePTFE the values were 16.92 N, 23.12 N and 25.41 N. A statistically significant difference was observed in postoperative week 1. The comparison between PP and ePTFE prosthetic implants in the conditions of the present research enabled the conclusion that: 1) the estimated area adhered to the prostheses was similar, irrespective of the implanted material; 2) at postoperative week 1, the resistance to traction was higher when the repair was done with PP mesh, which was correlated to a higher degree of collagen fiber aggregation in the implanted tissues; 3) at postoperative week 1, fewer visceral adhesions were formed on ePTFE group of animals; and 4) at postoperative weeks 2 and 4, the PP implant induced a smaller infiltration of inflammatory tissue and a larger deposit of collagen fibrils
106

Avaliação de endoprótese nacional em traquéia de coelhos. / Auto-expansible endoprosthesis. Biocompatibility in rabbits trachea.

Faria, Celso Murilo Nálio Matias de 22 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:38Z (GMT). No. of bitstreams: 1 celsomurilonmdefaria_dissert.pdf: 1426679 bytes, checksum: 62fc4b90d691c716aef67c9e6590368e (MD5) Previous issue date: 2011-11-22 / Introduction: the utilization of endoprosthesis has its main indication in the neoplasic obstructions do not surgically treatable. The foreign industry dependence is one of the barriers we found for the broad utilization of such devices. The relevance of this research is the development of a national prosthesis from easy access and low cost. Objective: to assess the biocompatibility of nitinol endoprosthesis with polyurethane in the rabbits trachea. Material and Method: Seventeen rabbits were studied from the New Zealand breed (Oryctolagus Sylvilagus), eight male and five female, with an average weight of 3255g (from 2570 to 4270g). The endoprosthesis were applied orally through laringoscopy, under general anesthesia and released in the middle third of the trachea. Radiological study was made to assure the placement of the endoprosthesis that allowed to compare the index of migration of the endoprosthesis in millimeters. The proposed time segment was 30 days. The microscopic variables study was proceeded: dilatation, incorporation and granolomatous tissue and histological cuts from the tracheal and lungs segments for microscopic study. The histological study measured the inflammatory process, the parietal alterations and the kind of epithelium observed in the tracheal bed. Results: Thirteen animals were included in the final study. The average segment time was 26 days (15 to 35 days in observation). Six animals underwent a radiological study during euthanasia and it was demonstrated displacement with migration of the prosthesis for the distal trachea in five animals. There was absence in one. It was shown the prosthesis had a complete expansion in seven animals and partial expansion in six. The incorporation of prosthesis in the tracheal lumen was observed in two animals and adhered in eleven. Granulomatous tissue was present in ten animals and absent in three. The histological study of the mucosa and submucosa showed inflammatory process predominantly of Polymorphonuclear cells as in the contact region with the prosthesis as in the proximal. The depth of the inflammatory process in the tracheal wall was larger in the tracheal area in contact with the prosthesis. The alterations of the respiratory epithelium: the metaplasia parameter was the most frequent in the area without contact with the prosthesis. Corrosion and ulceration were predominant in the area in contact with the prosthesis. The metaplasia parameter was the most frequent in the area in contact with the prosthesis. Conclusion: the nitinol endoprosthesis auto-expandable covered with polyurethane, produced by Braile Biomédica and implanted in the trachea of rabbits was easy to apply and liberation in the tracheal lumen. The endoprosthesis recovered with polyurethane showed in radiographic assessment distal migration, good radial expandability and formation of granuloma tissue. It was also observed an inflammatory process predominantly acute and restricted to the superficial portions of the trachea. The most frequent epithelium alterations in contact with the prosthesis were ulceration and regenerative hyperplasia. / Introdução: a utilização de endoprótese tem a principal indicação nas obstruções neoplásicas e nas obstruções não tratáveis cirurgicamente. A dependência da indústria estrangeira é uma das barreiras para utilização ampla destes dispositivos. A relevância deste trabalho é o desenvolvimento de uma prótese nacional de fácil acesso e baixo custo. Objetivo: avaliar endoprótese de nitinol revestida com poliuretano, na traqueia de coelhos. Material e Método: foram estudados 17 coelhos, da raça Nova Zelândia (Oryctolagus Cuniculus). Oito machos e nove fêmeas, com peso médio de 3522g (de 2570 a 4270g). As endopróteses foram aplicadas via oral, por meio de laringoscopia, sob anestesia geral, e liberadas no terço médio das traqueias. Realizou-se estudo radiológico para assegurar a posição da endoprótese que permitiu comparar o índice de migração da endoprótese em milímetros. O tempo proposto de seguimento foi de 30 dias. Procedeu-se ao estudo das variáveis macroscópicas: dilatação, incorporação e tecido de granulação e cortes histológicos dos segmentos traqueais e pulmonares para estudo microscópico. O estudo histológico mensurou o processo inflamatório, as alterações parietais e o tipo de epitélio observado no leito traqueal. Resultados: 13 animais foram incluídos no estudo definitivo. O tempo médio de seguimento foi 26 (15 a 35) dias em observação. Em seis animais submetidos a estudo radiológico por ocasião da eutanásia, demonstrou-se deslocamento com migração da prótese para traqueia distal, em cinco; ausência de migração em um. Demonstrou-se que a prótese tinha expansão completa em sete animais e parcial em seis. A incorporação da prótese na luz traqueal foi observada em dois animais, e aderido em 11. Tecido de granulação esteve presente em dez animais e ausente em três. O estudo histológico da mucosa e submucosa demonstrou processo inflamatório com predomínio de polimorfonucleares tanto na região em contato com a prótese quanto na proximal. A profundidade do processo inflamatório na parede traqueal foi maior na área traqueal em contato com a prótese. Das alterações do eptélio respiratório, o parâmetro metaplasia foi o mais frequente na área sem contato com a prótese. Corrosão e ulceração predominaram na área em contato com a prótese. Conclusões: A escolha do coelho no desenho do presente estudo prejudicou o resultado. Trata-se de estudo pioneiro tanto na utilização de coelho para estudo de endoprótese, quanto no desenvolvimento de endoprótese metálica autoexpansível nacional. As dificuldades foram naturais deste pioneirismo, mas prejudicaram o resultado final. A endoprótese autoexpansível de nitinol recoberta de poliuretano, produzida pela Braile Biomédica Ltda, (Brasil) e implantada na traqueia de coelhos, demonstrou-se de fácil aplicação e liberação na luz traqueal. Apresentou elevada taxa de migração, boa expansibilidade radial. Verificou-se alta frequência na formação de tecido de granulação e baixa permeabilidade. Observou-se ainda processo inflamatório predominantemente agudo e restrito ás porções superficiais da traquéia. As alterações epiteliais mais freqüentes em contato com a prótese foram ulceração e hiperplasia regenerativa.
107

Fatores preditivos do insucesso clínico no tratamento das fístulas esofagorrespiratórias com prótese metálica autoexpansível em pacientes com câncer esofágico / Predictive factors of clinical failure of treatment of malignant esophageal fistula with self-expandable metallic stents

Maria Sylvia Ierardi Ribeiro 11 September 2017 (has links)
INTRODUÇÃO: A fistula esofagorrespiratória é complicação temida do câncer esofágico avançado. A paliação com prótese metálica autoexpansível é método amplamente empregado, porém com resultados conflitantes. OBJETIVO: Identificar fatores associados ao insucesso clínico do tratamento da fístula esofagorrespiratória maligna com prótese metálica autoexpansível. MÉTODOS: Estudo retrospectivo através da análise de banco de dados elaborado de forma prospectiva de pacientes submetidos ao tratamento da fístula esofagorrespiratória maligna com prótese metálica autoexpansível entre janeiro de 2009 e fevereiro de 2016 em hospital terciário dedicado ao tratamento do câncer. Foram coletados dados quanto à: características demográficas, nível de albumina sérica, capacidade funcional do paciente, doença pulmonar infecciosa em atividade no momento da passagem da prótese, tratamentos oncológicos prévios, momento do diagnóstico da fístula, tamanho e localização do trajeto fistuloso. RESULTADOS: Um total de 71 pacientes foram incluídos no estudo (55 homens, idade média de 59 anos). Insucesso clínico ocorreu em 44.3% dos pacientes. ECOG 3 ou 4, desenvolvimento da fístula durante o tratamento do câncer esofágico e diâmetro da fístula >= 1 cm foram fatores preditivos do insucesso clínico. ECOG 3 ou 4, doença pulmonar infecciosa em atividade no momento da passagem da prótese e tratamento oncológico prévio com radioterapia foram fatores preditivos de menor sobrevida. O grau de disfagia melhorou significativamente 15 dias após a passagem da prótese. A taxa total de eventos adversos foi de 30%. Migração da prótese e a oclusão da mesma por crescimento tumoral nas extremidades da prótese foram os eventos adversos mais comumente observados. CONCLUSÃO: A prótese metálica autoexpansível é um método terapêutico efetivo para o tratamento da fístula esofagorrespiratória maligna, no entanto, ECOG 3 ou 4, desenvolvimento da fístula durante o tratamento do câncer esofágico e diâmetro da fístula >= 1cm foram fatores preditivos do insucesso clínico após a passagem da prótese / INTRODUCTION: Malignant esophagorespiratory fistula is a serious and life-threatening complication of esophageal cancer. Self-expandable metal stents placement is a well accepted palliative treatment, however, with conflicting results. OBJECTIVE: To identify risk factors associated with clinical failure after self-expandable metal stents placement for the treatment of malignant esophagorespiratory fistula. METHODS: This was a retrospective analysis of a prospectively maintained database used at a tertiary cancer hospital, with patients treated with SEMS placement for MERF between January 2009 and February 2016. The following variables were collected: patient demographics, serum albumin level, Eastern Cooperative Oncology Group (ECOG) performance status, pulmonary infection, previous oncologic treatment, moment of diagnosis of the malignant esophagorespiratory fistula, size and classification of the fistulous tract. RESULTS: A total of 71 patients (55 males, mean age 59 years) were considered for the final analysis. Clinical failure occurred in 44.3% of the patients. ECOG 3 or 4, fistula development during esophageal cancer treatment and fistula diameter >= 1cm were factors associated with increased risk of clinical failure. ECOG 3 or 4, pulmonary infection at the time of SEMS placement and prior radiation therapy were predictive factors associated with lower overall survival. Dysphagia scores improved significantly 15 days after stent insertion. The overall stent-related adverse events rate was 30%. Stent migration and occlusion due to tumor overgrowth were the most commonly seen adverse events. CONCLUSION: SEMS placement is a reasonable treatment option for MERF, however, ECOG 3 or 4, fistula development during esophageal cancer treatment or large fistula diameter may be independent predictors of clinical failure after stenting
108

Correção de defeitos ventrais em ratos com próteses de polipropileno e politetrafluoroetileno expandido: análises histológica, biomecânica e da resposta aderencial / Repair of abdominal wall defects in rats with polypropylene and expanded polytetrafluoroethylene prostheses: histological, biomechanical and adhesion formation analysis

Enio Campos Amico 30 March 2005 (has links)
Atualmente os defeitos herniários da parede abdominal são freqüentemente corrigidos com o uso de biomateriais. Embora utilizada com bons resultados há várias décadas, a prótese de Polipropileno (PP) tem implicado graves complicações decorrentes de aderências aos órgãos abdominais. A prótese de Politetrafluoroetileno expandido (PTFEe) tem reconhecidamente menor potencial aderencial; no entanto, dados obtidos de estudos biomecânicos deixam dúvida quanto a sua real eficiência na correção herniária. O objetivo do estudo foi comparar esses dois diferentes tipos de próteses na correção de defeitos ventrais produzidos em ratos Wistar, levando-se em consideração parâmetros histológicos, biomecânicos e da resposta aderencial. Para o estudo histológico um grupo de animais (n=21) foi submetido simultaneamente a implante subperitoneal de fragmentos de próteses de PP e PTFEe. Para o estudo comparativo da resposta biomecânica e aderencial entre as próteses, procedeu-se ao implante protético subperitoneal com PP (n=21) e PTFEe (n=21) para corrigir defeitos ventrais criados cirurgicamente envolvendo toda a espessura da parede abdominal dos animais. Para análise biomecânica, dois outros grupos de animais foram utilizados como controle: um grupo não submetido à cirurgia (n=15) e um grupo com correção de defeitos ventrais por meio de sutura (n=21). Todas as avaliações foram realizadas com 1, 2 e 4 semanas de pós-operatório e constituíram-se de: avaliação da resposta aderencial por meio de pesquisa da área de prótese aderida e incidência de aderência a órgãos, avaliação biomecânica por meio de ensaios de tração de tiras de parede abdominal e avaliação morfométrica do tecido inflamatório e das fibras colagênicas em cortes histológicos corados por Hematoxilina-eosina e pelo método da Picrossírius-polarização, respectivamente. Os resultados mostraram que: a fração de volume de tecido inflamatório no grupo PP na primeira, segunda e quarta semanas foi respectivamente: 20%, 9% e 4% enquanto no grupo PTFEe: 30%, 16% e 16%. Houve diferença estatística na segunda e quarta semanas. A fração de volume de colágeno fibrilar no grupo PP foi respectivamente: 65%, 71% e 77%, na primeira, segunda e quarta semanas. No grupo PTFEe os valores foram: 55%, 66% e 68%, na primeira, segunda e quarta semanas. Da mesma forma, houve diferença estatística na segunda e quarta semanas. Na análise semiquantitativa do grau de agregação de colágeno foi observado diferença estatística apenas primeira semana de pós-operatório a favor do PP (3,24 x 1,40 p=0,022). As próteses induziram valores semelhantes de área aderida na primeira (67,85%-PP x 71,42%- PTFEe), segunda (60,71%-PP x 60,71%-PTFEe) e quarta semanas de pós-operatório (46,42% PP x 42,85% PTFEe). Quanto à presença de aderência a órgãos abdominais houve diferença entre as próteses apenas na primeira semana a favor do PTFEe: enquanto 85,7% dos animais no grupo PP apresentaram aderências à órgãos, esse índice foi de apenas 28,5% no grupo PTFEe. Os valores de força máxima obtidos nos ensaios biomecânicos de tração com a prótese de PP foram na primeira, segunda e quarta semanas: 20,54 N, 21,62 N e 26,23 N. No grupo PTFEe os valores na primeira, segunda e quarta semanas foram: 16,92 N, 23,12 N e 25,41 N. Foi observada diferença estatística na primeira semana de pós-operatório. A comparação entre os implantes protéticos de PP e PTFEe nas condições da presente pesquisa permitiu concluir: 1) A estimativa de área aderida à prótese foi semelhante independentemente do material implantado; 2) Com 1 semana de pós-operatório, o implante de PP demonstrou-se mais resistente aos ensaios biomecânicos de tração o que se correlacionou a um maior grau de agregação das fibras colagênicas nos tecidos implantados; 3) Com 1 semana de pós-operatório, os implantes de PTFEe induziram aderências as órgãos abdominais em um menor número de animais; 4) Com 2 e 4 semanas de pós-operatório o implante de PP induziu a uma menor infiltração de tecido inflamatório e a um maior depósito de colágeno fibrilar / Nowadays, abdominal wall defects are frequently repaired with biomaterials. Although utilized with good results for several decades, polypropylene mesh (PP) has been implicated with serious complications due to adhesion to the abdominal organs. It has been reported that prostheses of expanded polytetrafluoroethylene (ePTFE) mesh exhibit less adhesion formation potential; however, data obtained by biomechanical studies leave doubt as to its real efficiency in hernia repair. The objective of the present study was to compare these two types of mesh in the correction of ventral defects created in Wistar rats, taking into account histological and biomechanical parameters and the adhesion response. For the histological study, a group of animals (n = 21) was submitted simultaneously to subperitoneal implantation of fragments of PP and ePTFE mesh. For the comparative study of the biomechanical and adhesion response between the prostheses, subperitoneal implantation with PP (n = 21) and ePTFE mesh (n = 21) was performed to repair surgically created abdominal defects, involving all layers of the abdominal wall. In the biomechanical analysis, two other groups of animals were used for the control: a group not submitted to surgery (n = 15) and a group with abdominal wall defects repaired with sutures (n = 21). At postoperative weeks 1, 2 and 4, the following evaluations were performed: study of the adhesion response by measuring the incidence of adherence to organs and area of adhered prosthesis; biomechanical test of abdominal wall strips; and morphometric study of the inflammatory tissue and collagenic fibers in sections stained with hematoxylin-eosin and by Picrosiriuspolarization technique. The results showed that: the inflammatory tissue volume in group PP at postoperative weeks 1, 2 and 4, respectively, was 20%, 9% and 4%; while in the group ePTFE the values were 30%, 16% and 16%. The difference was statistically significant in postoperative weeks 1 and 4. The collagen fibril volume in group PP was: 65%, 71% and 77%, in postoperative weeks 1, 2 and 4, respectively. In group ePTFE the values were: 55%, 66% and 68%. Likewise, there was a statistically significant difference in postoperative weeks 2 and 4. In the semi-quantitative analysis of the degree of collagen aggregation, a statistically significant difference was only observed in postoperative week 1, in favor of PP (3.24 x 1.40, p = 0.022). The prostheses induced similar values for adhered area in postoperative week 1 (67.85%-PP vs. 71.42%-ePTFE), week 2 (60.71%-PP vs. 60.71%-ePTFE) and week four (46.42% PP vs. 42.85% ePTFE). Regarding the presence of adherence to abdominal organs, there was only a statistically significant difference between the prostheses in week one, in favor of ePTFE. While 85.7% of the animals in group PP presented adherence to organs, this index was only 28.5% in group ePTFE. The maximum force obtained in the biomechanical tests with the PP mesh was 20.54 N, 21.62 N and 26.23 N, in postoperative weeks 1, 2 and 4, respectively. In group ePTFE the values were 16.92 N, 23.12 N and 25.41 N. A statistically significant difference was observed in postoperative week 1. The comparison between PP and ePTFE prosthetic implants in the conditions of the present research enabled the conclusion that: 1) the estimated area adhered to the prostheses was similar, irrespective of the implanted material; 2) at postoperative week 1, the resistance to traction was higher when the repair was done with PP mesh, which was correlated to a higher degree of collagen fiber aggregation in the implanted tissues; 3) at postoperative week 1, fewer visceral adhesions were formed on ePTFE group of animals; and 4) at postoperative weeks 2 and 4, the PP implant induced a smaller infiltration of inflammatory tissue and a larger deposit of collagen fibrils
109

Comparação entre prótese plástica e metálica na paliação endoscópica da obstrução maligna da via biliar: revisão sistemática e metanálise baseadas em estudos randomizados / Endoscopic stenting for inoperable malignant biliary obstruction: a systematic review and meta-analysis

Leonardo Zorrón Cheng Tao Pu 12 April 2016 (has links)
INTRODUÇÃO: A prótese biliar endoscópica é aceita em todo o mundo como a primeira escolha de tratamento paliativo na obstrução biliar maligna. Atualmente ainda persistem dois tipos de materiais utilizados em sua confecção: plástico e metal. Consequentemente, muitas dúvidas surgem quanto a qual deles é o mais benéfico para o paciente. Esta revisão reúne as informações disponíveis da mais alta qualidade sobre estes dois tipos de prótese, fornecendo informações em relação à disfunção, complicação, taxas de reintervenção, custos, sobrevida e tempo de permeabilidade; e pretende ajudar a lidar com a prática clínica nos dias de hoje. OBJETIVO: Analisar, através de metanálise, os benefícios de dois tipos de próteses na obstrução biliar maligna inoperável. MÉTODOS: Uma revisão sistemática de ensaios clínicos randomizados (RCT) foi conduzida, com a última atualização em março de 2015, utilizando EMBASE, CINAHL (EBSCO), Medline, Lilacs / Centro (BVS), Scopus, o CAPES (Brasil), e literatura cinzenta. As informações dos estudos selecionados foram extraídas tendo em vista seis desfechos: primariamente disfunção, taxas de reintervenção e complicações; e, secundariamente, custos, sobrevivência e tempo de permeabilidade. Os dados sobre as características dos participantes do RCT, critérios de inclusão e exclusão e tipos de próteses também foram extraídos. Os vieses foram avaliados principalmente através da escala de Jadad. Esta metanálise foi registrada no banco de dados PROSPERO pelo número CRD42014015078. A análise do risco absoluto dos resultados foi realizada utilizando o software RevMan 5, calculando as diferenças de risco (RD) de variáveis dicotômicas e média das diferenças (MD) de variáveis contínuas. Os dados sobre a RD e MD para cada desfecho primário foram calculados utilizando o teste de Mantel-Haenszel e a inconsistência foi avaliada com o teste Qui-quadrado (Chi2) e o método de Higgins (I2). A análise de sensibilidade foi realizada com a retirada de estudos discrepantes e a utilização do efeito aleatório. O teste t de Student foi utilizado para a comparação das médias aritméticas ponderadas, em relação aos desfechos secundários. RESULTADOS: Inicialmente foram identificados 3660 estudos; 3539 foram excluídos por título ou resumo, enquanto 121 estudos foram totalmente avaliados e foram excluídos, principalmente por não comparar próteses metálicas (SEMS) e próteses plásticas (PS), levando a treze RCT selecionados e 1133 indivíduos metanálise. A média de idade foi de 69,5 anos, e o câncer mais comum foi de via biliar (proximal) e pancreático (distal). O diâmetro de SEMS mais utilizado foi de 10 mm (30 Fr) e o diâmetro de PS mais utilizado foi de 10 Fr. Na metanálise, SEMS tiveram menor disfunção global em comparação com PS (21,6% versus 46,8% p < 0,00001) e menos reintervenções (21,6% versus 56,6% p < 0,00001), sem diferença nas complicações (13,7% versus 15,9% p = 0,16). Na análise secundária, a taxa média de sobrevida foi maior no grupo SEMS (182 contra 150 dias - p < 0,0001), com um período maior de permeabilidade (250 contra 124 dias - p < 0,0001) e um custo semelhante por paciente, embora menor no grupo SEMS (4.193,98 contra 4.728,65 Euros - p < 0,0985). CONCLUSÃO: SEMS estão associados com menor disfunção, menores taxas de reintervenção, melhor sobrevida e maior tempo de permeabilidade. Complicações e custos não apresentaram diferença / INTRODUCTION: Endoscopic stenting is accepted worldwide as the first choice palliative treatment for malignant biliary obstruction. There are still two types of materials currently being used, which are plastic and metal. Therefore, many doubts are raised as to which one is the most beneficial to the patient. This review gathers the highest quality information available about these two types of stent, giving information in regards to dysfunction, complication, reintervention rates, costs, survival, and patency time; and intends to help handle clinical practice nowadays. OBJECTIVE: To analyze through meta-analyses the benefits of two types of stents in the inoperable malignant biliary obstruction. METHODS: A systematic review of randomized clinical trials (RCT) was conducted, with the last update on March 2015, using EMBASE, CINAHL (EBSCO), MEDLINE, LILACS/CENTRAL (BVS), SCOPUS, CAPES (Brazil), and gray literature. Information of the selected studies was extracted in sight of six outcomes: primarily regarding dysfunction, reintervention and complication rates; and secondarily costs, survival, and patency time. The data about characteristics of trial participants, inclusion and exclusion criteria and types of stents were also extracted. The biases were mainly assessed through the Jadad scale. This meta-analysis was registered in the PROSPERO database by the number CRD42014015078. The analysis of the absolute risk of the outcomes was performed using the software RevMan 5, by computing risk differences (RD) of dichotomous variables and mean differences (MD) of continuous variables. Data on RD and MD for each primary outcome were calculated using the Mantel-Haenszel test and inconsistency was qualified and reported in Chisquared (Chi2) and the Higgins method (I2). Sensitivity analysis was performed withdrawing discrepant studies and using random effect. Student\'s t-test was used for the comparison of weighted arithmetic means regarding secondary outcomes. RESULTS: Initial searching identified 3660 studies; 3539 were excluded through title or abstract, while 121 studies were fully assessed and were excluded mainly because they did not compare Self Expanding Metal Stents (SEMS) and Plastic Stents (PS), leading to thirteen RCT selected and 1133 subjects meta-analyzed. The mean age was 69.5 years old, that were affected mostly by bile duct (proximal) and pancreatic tumors (distal). The preferred SEMS diameter used was the 10 mm (30 Fr) and the preferred PS diameter used was 10 Fr. In the meta-analysis, SEMS had lower overall stent dysfunction compared to PS (21.6% versus 46.8% p < 0.00001) and fewer reintervention (21.6% versus 56.6% p < 0.00001), with no difference in complications (13.7% versus 15.9% p=0.16). In the secondary analysis, the mean survival rate was higher in the SEMS group (182 versus 150 days - p < 0.0001), with a higher patency period (250 versus 124 days - p < 0.0001) and a similar cost per patient, although lower in the SEMS group (4193.98 versus 4728.65 Euros - p < 0.0985). CONCLUSION: SEMS are associated with lower stent dysfunction, lower reintervention rates, better survival, and higher patency time. Complications and costs do not show difference
110

Avaliação da percepção auditiva da fala em pacientes submetidos ao reimplante coclear / Evaluation of auditory speech perception in patients submitted to cochlear reimplantation

Lucas Bevilacqua Alves da Costa 18 July 2018 (has links)
Estudo retrospectivo, descritivo e longitudinal realizado na Seção de Implante Coclear, Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo (IC-CPA/HRAC/USP). O objetivo deste estudo foi caracterizar o desempenho da percepção auditiva da fala de indivíduos submetidos à cirurgia de reimplante coclear. No total de 1.323 indivíduos submetidos à cirurgia de implante coclear no período de 1990 a janeiro de 2016, consta o registro de 84 indivíduos submetidos à cirurgia de reimplante coclear, correspondendo a 6,3% do total. Deste total de 84, 68 indivíduos atenderam aos critérios de inclusão/exclusão da pesquisa e foram avaliados utilizando-se testes de percepção auditiva da fala, em três momentos: antes da segunda intervenção cirúrgica, após o reimplante e última avaliação de acompanhamento. As variáveis estudadas foram: a) motivo do reimplante coclear; b) etiologia da perda auditiva; c) idade na primeira cirurgia; d) tempo de uso do implante coclear antes do reimplante; e) tempo de recuperação do escore anterior à intervenção; f) tempo de uso atual; g) escore nos procedimentos de avaliação da percepção auditiva da fala, pré e pós-reimplante coclear. Na análise dos dados foi possível observar que a causa mais comum do reimplante foi a falha do dispositivo interno, seguido de razões médicas. Na avaliação auditiva da fala, um total de 61 (89,7%) recuperaram o desempenho observado antes do reimplante coclear e sete (10,3%), não alcançaram o mesmo desempenho. Constatou-se que as variáveis idade do primeiro Implante e tempo de uso do primeiro Implante Coclear, assim como tempo de reimplante, influenciaram nos resultados encontrados. A cirurgia de reimplante coclear é um procedimento viável, contudo a família e o paciente devem ser orientados quanto aos possíveis comprometimentos na percepção auditiva da fala / A retrospective, descriptive and longitudinal study performed in the Cochlear Implant Section, Audiological Research Center of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (IC-CPA / HRAC / USP). This study aimed at characterizing the auditory speech perception of individuals undergoing cochlear reimplantation surgery. Out of 1,323 individuals undergoing cochlear implant surgery from 1990 to January 2016, 84 (6.3%) subjects underwent cochlear reimplantation surgery. From this total of 84, 68 individuals met the inclusion / exclusion criteria of the study and were evaluated using auditory speech perception tests in three moments: before the second surgical intervention, after reimplantation and the last follow-up evaluation. The variables studied were: a) reason for cochlear reimplantation; b) etiology of hearing loss; c) age at first surgery; d) time cochlear implant use before reimplantation; e) recovery time from the previous intervention score; f) time of current use; g) score in the procedures of assessment of auditory speech perception before and after cochlear reimplantation. The data analysis showed that the most common cause of reimplantation was the failure of the internal device, followed by medical reasons. In the auditory speech evaluation, a total of 61 (89.7%) recovered performance before cochlear reimplantation, and seven (10.3%), did not reach the same performance. It was verified that the variables age at the first Implant and time using the first Cochlear Implant, as well as time of reimplantation, influenced the results. Cochlear replantation surgery is a viable procedure, however, the family and the patient should be advised on the possible compromising risks to the auditory speech perception

Page generated in 0.064 seconds