• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • Tagged with
  • 39
  • 39
  • 35
  • 24
  • 21
  • 19
  • 18
  • 18
  • 12
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Curva diária de pressão intraocular em porquinhos da índia (Cavia porcellus) de diferentes faixas etárias com tonometria de rebote

Ghiggi, Eduardo January 2016 (has links)
A aferição da pressão intraocular (PIO) é essencial para o exame oftálmico. Objetivou-se estabelecer os valores da curva diária da PIO de porquinhos da índia de diferentes faixas etárias com tonômetro de rebote. A PIO foi aferida às 6, 12, 18 e 24 horas utilizando o tonômetro de rebote (Tonovet®). Os porquinhos da índia foram subdivididos em dois grupos com 10 animais no grupo I e 4 animais no grupo II, considerando as idades, designados por GI (animais entre 2 a 3 meses de idade) e GII (animais entre 2 a 3 anos de idade). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos animais. O valor médio da pressão intraocular foi de 12,0 ± 1,83 mmHg. Foram encontradas diferenças significativas entres as idades, sendo que os valores médios para o grupo I foram 11,63 ± 0,29 mmHg, e para o grupo II foram 12,82 ± 0,45mmHg (P= 0,0295). Não foram encontradas diferenças entre ambos os olhos (P= 0,7454). Não foram encontradas diferenças significativas nos valores da PIO relacionadas ao sexo (P= 0,1858). Os valores da PIO em porquinhos da índia tiveram alteração nas horas avaliadas. Com base nos resultados obtidos foi possível concluir que os valores da PIO em porquinhos da índia da sofrem alterações ao longo do dia. Os menores valores de pressão intraocular ocorreram às 18 horas. / The measuring of intraocular pressure (IOP) it is essential for the ophthalmic evaluation; the aim of this study was establish the values of the IOP diurnal curve of guinea pigs with different ages using the rebound tonometer (Tonovet®). The animals were divided according to the age in two groups, Group I (GI) constituted with 10 guinea pigs aged between 2 -3 moths, and Group II (GII), 4 animals with 2 -3 years of old. Previously the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp, and direct optalmoscopy were performed on all animals. The men value of IOP was 12.0±0.34 mmHg. Statistical difference were found between ages (mean GI 11.64 ± 0.29 mmHg, and GII 12.83 ± 0.45mmHg), did not have statistical difference related with gender (P= 0.1858) or between eyes (P= 0.7454). In conclusion the guinea pigs had alteration of IOP true the day, the values of IOP are higher in the morning period, decrease true the day and at the night period haves an elevation again.
22

Pressão intra-ocular em pré-termos de muito baixo peso de nascimento e sua relação com a idade pós-concepção

Lindenmeyer, Rodrigo Leivas January 2012 (has links)
Objetivo: medir a pressão intra-ocular (PIO) em pré-termos de muito baixo peso (PMBP) e correlacionar com a idade pós-concepção (IPC). Métodos: Estudo longitudinal incluindo 50 pré-termos. Local: Hospital de Clínicas de Porto Alegre. Período: entre novembro de 2008 e junho de 2010. Pacientes: PMBP definido como idade nascimento ≤ 1.500 g e idade gestacional ≤ 32 semanas. Intervenção: medidas semanais da PIO. Principais desfechos: variação da PIO de acordo com a idade pós-concepção (IPC definida como a idade gestacional ao nascimento mais a idade no momento do exame) nas semanas seguintes ao nascimento pré-termo. Análise estatística: modelos de efeitos mistos foram utilizados para determinar a variação da PIO em relação a IPC. Foram calculados as médias e os percentis 10 e 90 (P10 e P90) para os valores da PIO. Resultados: Cinqüenta PMBP com idade gestacional média de 29,7 ± 1,6 semanas e peso de nascimento de 1.127,7 ± 222,7 gramas foram avaliados. Não houve diferença significativa entre a PIO do olho direito e do olho esquerdo (p=0.177). A média da PIO em toda a coorte, considerando ambos os olhos, foi de 14,9 ± 4,5 mmHg, sendo que 13,5% das medidas isoladas da PIO foram superiores a 20 mmHg. A PIO reduziu em média 0,29 mmHg para cada aumento de uma semana da IPC (p=0.047 IC95%: -0,58 a -0,0035). A PIO média (P10-P90) reduziu de 16,3 mmHg (10,52-22,16) com 26,3 semanas de IPC para 13,1 mmHg (7,28-18,92) com 37,6 semanas de IPC. Conclusões: A PIO média em PMBP foi 14,9 ± 4,5 mmHg e apresentou correlação negativa em relação a idade pós-concepção. / Purpose: To measure intraocular pressure (IOP) in very low birth weight preterm infants and correlate it with the postconceptional age (PCA). Methods: Longitudinal study including 50 premature infants. Setting: Hospital de Clinicas de Porto Alegre, Brazil. Patients: Very low birth weight premature infants (defined as birth weight ≤1,500 g and gestational age ≤32 weeks). Intervention: Weekly measurements of the IOP. Main outcomes: The variation of IOP according to the postconceptional age (PCA defined as the gestational age at birth plus the age in weeks at the time of examination) in the weeks following preterm birth. Statistics: Mixed-effects models were used for the statistical analysis to determine IOP variation according to PCA. Means, 10th and 90th percentiles were calculated for IOP values. Results: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and mean birth weight of 1,127.7 ± 222.7 grams were evaluated. Mean IOP in the whole cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of the IOP measurement values were greater than 20 mmHg. The analysis revealed a mean IOP reduction of 0.29 mmHg for each increase of PCA (p=0.047; 95% CI, -0.58 to -0.0035). Mean IOP (P10- P90) decreased from 16.3 mmHg (10.52-22.16) at 26.3 weeks PCA to 13.1 mmHg (7.28- 18.92) at 37.6 weeks PCA. Conclusions: Mean IOP in very low birth weight preterm infants was 14.9 ± 4.5 mmHg and was negatively correlated with PCA.
23

Estudo comparativo entre a tonometria de rebote e a tonometria de aplanação em equinos da raça crioula (Equus cabbalus)

Andrade, Maria Cristina Caldart de January 2011 (has links)
A aferição da pressão intraocular (PIO) é importante para o diagnóstico e acompanhamento de doenças oculares. Métodos fidedignos para quantificar a PIO de maneira acurada têm sido buscados. Com o aparecimento de tonômetros portáteis, a avaliação da pressão intraocular em equinos tem se intensificado e os diferentes princípios de aferição têm sido comparados. Este estudo objetivou a comparação entre a tonometria de aplanação, realizada com o Tono-Pen Avia®, e tonometria de rebote, realizada com o Tonovet®, em equinos da raça Crioula. Além disso, a utilização, ou não, do cachimbo como método de contenção também foi comparada e submetida à análise estatística. Foram avaliados 30 cavalos com idades entre dois e 20 anos, machos ou fêmeas. Exame oftálmico prévio foi realizado com teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta. A tonometria de aplanação foi realizada, no mínimo, 30 minutos após a tonometria de rebote. A pressão intraocular média do Tonovet® foi maior, 36,82 ± 5,91mmHg com cachimbo e 30,04 ± 3,19mmHg sem. A do Tono-Pen Avia® foi de 26,43 ± 5,48 mmHg com cachimbo e 23,10 ±4,01mmHg sem. Todos os resultados diferiram estatisticamente entre si. Quando comparados os sexos, o Tono-Pen Avia® não mostrou diferenças, enquanto o Tonovet® mostrou pressões maiores para cavalos castrados e garanhões, e menores para éguas (p<0,001) com a utilização do cachimbo. Não há correlação entre a idade dos cavalos e os valores de PIO, independente do aparelho (p > 0,05). Os valores da PIO com o Tonovet® foram maiores do que os obtidos com o Tono-Pen Avia®. A contenção dos animais com cachimbo eleva a pressão intraocular em equinos. / Intraocular pressure evaluation is important for diagnosis and control of ophthalmic diseases. Accurate methods to quantify intraocular pressure have been searched. With the development of handheld tonometers, equine intraocular pressure evaluation has been intensified and the different principles of measurement have been compared. The objective of this study was to compare the applanation tonometry, taken with the Tono- Pen Avia® and the rebound tonometry, taken with the Tonovet® in adult “crioulo” breed horses. The age, gender and the use of upper lip twitch as a restraint method was also surveyed and submitted to statistical analysis. Thirty horses, aged two to 20, male or female were evaluated. A previous ophthalmic examination was performed with Schirmer tear test, fluoresceine test, slit lamp biomicroscopy and direct ophthalmoscopy in all animals. Applanation tonometry was performed, at least, 30 minutes after rebound tonometry. Intraocular pressure mean values measured with the Tonovet® was higher, 36,82±5,91mmHg with the lip twitch and 30,04±3,19mmHg without. Tonopen Avia® mean values were 26,43±5,48mmHg with the lip twitch and 23,10±4,1mmHg without. All results was statistical different between themselves. When genders were compared the Tono-Pen Avia® revealed no difference, however the Tonovet® showed higher pressures for male horses (p‹0,001) with the use of lip twitch. There was no correlation between age and intraocular pressure in “crioulo” horses, regardless of the equipment tested (p›0,05). Intraocular pressure mean values measured with the Tonove®t were higher than those obtained with the Tono-Pen Avia®. The restraint of animals with upper lip twitch increases equine intraocular pressure.
24

Estudo comparativo entre a tonometria de rebote e a tonometria de aplanação em equinos da raça crioula (Equus cabbalus)

Andrade, Maria Cristina Caldart de January 2011 (has links)
A aferição da pressão intraocular (PIO) é importante para o diagnóstico e acompanhamento de doenças oculares. Métodos fidedignos para quantificar a PIO de maneira acurada têm sido buscados. Com o aparecimento de tonômetros portáteis, a avaliação da pressão intraocular em equinos tem se intensificado e os diferentes princípios de aferição têm sido comparados. Este estudo objetivou a comparação entre a tonometria de aplanação, realizada com o Tono-Pen Avia®, e tonometria de rebote, realizada com o Tonovet®, em equinos da raça Crioula. Além disso, a utilização, ou não, do cachimbo como método de contenção também foi comparada e submetida à análise estatística. Foram avaliados 30 cavalos com idades entre dois e 20 anos, machos ou fêmeas. Exame oftálmico prévio foi realizado com teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta. A tonometria de aplanação foi realizada, no mínimo, 30 minutos após a tonometria de rebote. A pressão intraocular média do Tonovet® foi maior, 36,82 ± 5,91mmHg com cachimbo e 30,04 ± 3,19mmHg sem. A do Tono-Pen Avia® foi de 26,43 ± 5,48 mmHg com cachimbo e 23,10 ±4,01mmHg sem. Todos os resultados diferiram estatisticamente entre si. Quando comparados os sexos, o Tono-Pen Avia® não mostrou diferenças, enquanto o Tonovet® mostrou pressões maiores para cavalos castrados e garanhões, e menores para éguas (p<0,001) com a utilização do cachimbo. Não há correlação entre a idade dos cavalos e os valores de PIO, independente do aparelho (p > 0,05). Os valores da PIO com o Tonovet® foram maiores do que os obtidos com o Tono-Pen Avia®. A contenção dos animais com cachimbo eleva a pressão intraocular em equinos. / Intraocular pressure evaluation is important for diagnosis and control of ophthalmic diseases. Accurate methods to quantify intraocular pressure have been searched. With the development of handheld tonometers, equine intraocular pressure evaluation has been intensified and the different principles of measurement have been compared. The objective of this study was to compare the applanation tonometry, taken with the Tono- Pen Avia® and the rebound tonometry, taken with the Tonovet® in adult “crioulo” breed horses. The age, gender and the use of upper lip twitch as a restraint method was also surveyed and submitted to statistical analysis. Thirty horses, aged two to 20, male or female were evaluated. A previous ophthalmic examination was performed with Schirmer tear test, fluoresceine test, slit lamp biomicroscopy and direct ophthalmoscopy in all animals. Applanation tonometry was performed, at least, 30 minutes after rebound tonometry. Intraocular pressure mean values measured with the Tonovet® was higher, 36,82±5,91mmHg with the lip twitch and 30,04±3,19mmHg without. Tonopen Avia® mean values were 26,43±5,48mmHg with the lip twitch and 23,10±4,1mmHg without. All results was statistical different between themselves. When genders were compared the Tono-Pen Avia® revealed no difference, however the Tonovet® showed higher pressures for male horses (p‹0,001) with the use of lip twitch. There was no correlation between age and intraocular pressure in “crioulo” horses, regardless of the equipment tested (p›0,05). Intraocular pressure mean values measured with the Tonove®t were higher than those obtained with the Tono-Pen Avia®. The restraint of animals with upper lip twitch increases equine intraocular pressure.
25

Pressão intra-ocular em pré-termos de muito baixo peso de nascimento e sua relação com a idade pós-concepção

Lindenmeyer, Rodrigo Leivas January 2012 (has links)
Objetivo: medir a pressão intra-ocular (PIO) em pré-termos de muito baixo peso (PMBP) e correlacionar com a idade pós-concepção (IPC). Métodos: Estudo longitudinal incluindo 50 pré-termos. Local: Hospital de Clínicas de Porto Alegre. Período: entre novembro de 2008 e junho de 2010. Pacientes: PMBP definido como idade nascimento ≤ 1.500 g e idade gestacional ≤ 32 semanas. Intervenção: medidas semanais da PIO. Principais desfechos: variação da PIO de acordo com a idade pós-concepção (IPC definida como a idade gestacional ao nascimento mais a idade no momento do exame) nas semanas seguintes ao nascimento pré-termo. Análise estatística: modelos de efeitos mistos foram utilizados para determinar a variação da PIO em relação a IPC. Foram calculados as médias e os percentis 10 e 90 (P10 e P90) para os valores da PIO. Resultados: Cinqüenta PMBP com idade gestacional média de 29,7 ± 1,6 semanas e peso de nascimento de 1.127,7 ± 222,7 gramas foram avaliados. Não houve diferença significativa entre a PIO do olho direito e do olho esquerdo (p=0.177). A média da PIO em toda a coorte, considerando ambos os olhos, foi de 14,9 ± 4,5 mmHg, sendo que 13,5% das medidas isoladas da PIO foram superiores a 20 mmHg. A PIO reduziu em média 0,29 mmHg para cada aumento de uma semana da IPC (p=0.047 IC95%: -0,58 a -0,0035). A PIO média (P10-P90) reduziu de 16,3 mmHg (10,52-22,16) com 26,3 semanas de IPC para 13,1 mmHg (7,28-18,92) com 37,6 semanas de IPC. Conclusões: A PIO média em PMBP foi 14,9 ± 4,5 mmHg e apresentou correlação negativa em relação a idade pós-concepção. / Purpose: To measure intraocular pressure (IOP) in very low birth weight preterm infants and correlate it with the postconceptional age (PCA). Methods: Longitudinal study including 50 premature infants. Setting: Hospital de Clinicas de Porto Alegre, Brazil. Patients: Very low birth weight premature infants (defined as birth weight ≤1,500 g and gestational age ≤32 weeks). Intervention: Weekly measurements of the IOP. Main outcomes: The variation of IOP according to the postconceptional age (PCA defined as the gestational age at birth plus the age in weeks at the time of examination) in the weeks following preterm birth. Statistics: Mixed-effects models were used for the statistical analysis to determine IOP variation according to PCA. Means, 10th and 90th percentiles were calculated for IOP values. Results: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and mean birth weight of 1,127.7 ± 222.7 grams were evaluated. Mean IOP in the whole cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of the IOP measurement values were greater than 20 mmHg. The analysis revealed a mean IOP reduction of 0.29 mmHg for each increase of PCA (p=0.047; 95% CI, -0.58 to -0.0035). Mean IOP (P10- P90) decreased from 16.3 mmHg (10.52-22.16) at 26.3 weeks PCA to 13.1 mmHg (7.28- 18.92) at 37.6 weeks PCA. Conclusions: Mean IOP in very low birth weight preterm infants was 14.9 ± 4.5 mmHg and was negatively correlated with PCA.
26

Estudo sobre a deformação da córnea utilizando o sistema de tonometria de não contato integrado a uma câmera de Scheimpflug em olhos saudáveis / Evaluation of corneal deformation analyzed with non-contact tonometer system integrated with an ultra-high-speed (UHS) Scheimpflug camera in healthy eyes

Bruno de Freitas Valbon 23 September 2016 (has links)
OBJETIVOS: 1) Avaliar os parâmetros de biomecânica ocular provenientes do Corvis ST (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) obtidos de olhos saudáveis de uma população de pacientes brasileiros. 2) Correlacionar os parâmetros derivados do Corvis ST com a idade de pacientes jovens saudáveis. 3) Verificar se as técnicas de facoemulsificação (FC) e do laser de femtosegundo (LFS), empregadas na correção cirúrgica de catatara, influenciam os parâmetros de biomecânica ocular provenientes do Corvis ST. 4) Analisar as alterações da deformação da córnea observadas em um caso de ectasia pós LASIK com flap espesso. MÉTODOS: 1) Estudo clínico transversal conduzido em 90 pacientes (90 olhos saudáveis). Foram avaliados 11 parâmetros derivados do sistema de tonometria de não contato integrado com a câmera ultrarrápida de Scheimpflug (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany), a saber: deformidade de amplitude (DA); pressão intraocular; 1st A time; tempo de concavidade máxima; 2nd A time; 1st A Length (tempo da primeira aplanação); 2nd A Length (tempo da segunda aplanação); raio de curvatura de maior alcance; raio de curvatura normal; velocidade de entrada (Vin) e de saída (Vout). Estes parâmetros foram correlacionados com a espessura central corneana mensurada pela Tomografia de Córnea e Segmento Anterior (Pentacam® - Oculus, Wetzlar, Germany). 2) Estudo clínico observacional, retrospectivo, conduzido em 89 pacientes (89 olhos saudáveis). Os parâmetros derivados do Corvis ST foram correlacionados com a idade dos pacientes. 3) Estudo clínico prospectivo, envolvendo 151 olhos de 127 pacientes com diagnóstico de catarata nuclear. Setenta e cinco olhos de 65 pacientes foram submetidos à técnica do laser de femtosegundo (AlconLenSx, Aliso Viejo, USA) e 76 olhos de 62 pacientes à facoemulsificação convencional (Alcon Infinit, Fort Worth, USA). Foram avaliados os 11 parâmetros de biomecânica ocular derivados do Corvis ST antes (Pré) e após as cirurgias de catarata (D1, primeiro dia de pósoperatório). A densitometria do cristalino (scattering) foi realizada pelo PNS (Pentacam Nucleus Staging). 4) Avaliação com tomografia de coerência óptica de espessura dos flaps corneanos pós Lasik e análise dos parâmetros biomecânicos provenientes do Corvis ST em uma córnea com ectasia pós Lasik. RESULTADOS: 1) A média de idade dos pacientes foi de 35,80 ± 12,83 anos. A média do equivalente esférico foi de -3,29 ± 3,69 dioptrias. A média da espessura central corneana foi de 547,50 ± 32,00 ?m Os valores dos 11 parâmetros biomecânicos obtidos de olhos saudáveis, foram os seguintes: deformidade de amplitude 1,05 ± 0,08 mm; tempo de concavidade máxima 18,38 ± 0,93 ms; pressão intraocular 16,43 ± 2,15 mmHg; tempo da primeira aplanação (1st A time) 8,32 ± 0,33 ms; tempo da segunda aplanação 23,80 ± 0,44 ms; raio de curvatura de maior alcance 11,09 ± 2,06 mm; raio de curvatura normal 7,59 ± 0,67 mm; tempo da primeira aplanação (1st A Length) 2,07 ± 0,38 mm; tempo da segunda aplanação (2nd A Length) 2,37 ± 0,47 mm; velocidade de entrada (Vin) 0,21 ± 0,05 m/s e velocidade de saída (Vout) -0,33 ± 0,07 m/s. 2) A média de idade dos pacientes foi de 27,50 ± 6,30 anos. O tempo de concavidade máxima alcançada da córnea (HC-time) foi o único dos 11 parâmetros que apresentou correlação significativa com a idade (p=0,04, rs=0,18). 3) A média de idade dos pacientes dos grupos LFS (laser de femtosegundo) e FC (facoemulsificação convencional) foram, respectivamente, 67,6 ± 9,9 anos e 68,4 ± 11,8 anos. No grupo LFS, 9 dos 11 parâmetros foram estatisticamente significativos entre o Pré e D1; e no grupo FC, 7 dos 11 parâmetros foram estatisticamente significativos entre o Pré e D1. Entre os 11 parâmetros biomecânicos avaliados, somente o tempo de concavidade máxima da córnea (HC-time) foi significativamente diferente entre os dois grupos em D1 (p=0,0387). 4) Paciente do sexo feminino, 45 anos, submetida à Lasik em ambos os olhos. Com a utilização da tomografia de coerência óptica (OCT Rtvue, OptoVue, Fremont, CA,USA) foram identificados: um flap com espessura central de 392 ?m no OD e dois cortes, sendo um flap incompleto profundo e o outro mais fino superiormente, no OE. Os parâmetros derivados do Corvis ST como a deformidade de amplitude são diferentes em ambos os olhos. CONCLUSÕES: 1) Os valores de 8 dos 11 parâmetros derivados do Corvis ST foram influenciados pela espessura central da córnea, porém esta influência foi baixa. 2) Em olhos saudáveis de pacientes jovens foi obtida correlação significativa entre a idade e o tempo de concavidade máxima, que é o tempo do início de aplanação até a concavidade máxima alcançada da córnea. 3) O laser de femtosegundo para cirurgia de catarata e a técnica de facoemulsificação convencional induziram alterações nas propriedades biomecânicas da córnea no D1. Dos 11 parâmetros biomecânicos estudados apenas o tempo de concavidade máxima da córnea apresentou diferença significativa entre os grupos (LFS e FC) no D1. 4) A ectasia unilateral após LASIK pode ocorrer devido a flap espesso com falência biomecânica da córnea / PURPOSE: 1) To evaluate ocular biomechanical metrics given by the CorVis ST (Oculus, Inc., Berlin, Germany) in a population of healthy Brazilian patients. 2) To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. 3) To evaluate the changes of corneal biomechanical after femtosecond laser - assisted cataract (FS) and to compare the parameters derived by Corvis ST between standard phacoemulsification (SP) and femtosecond laser - assisted in cataract surgery. 4) To report a case of post-LASIK corneal ectasia due to a thick flap, while the contralateral eye did not develop ectasia after an incomplete deep flap cut, followed by a thinner flap Lasik procedure. METHODS: 1) An observational and cross-sectional study involving 1 eye randomly selected from 90 healthy patients. Studied parameters (including deformation amplitude, first applanation time, highest concavity time, second applanation time, first applanation length, second applanation length, curvature radius highest concavity, curvature radius normal, velocity in, and velocity out) derived from the CorVis ST were correlated to central corneal thickness from the Pentacam (Oculus, Inc.). Differences between data on the basis of gender were evaluated. 2) Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy eyes. The Scheimpflug images were taken with an ultra-high-speed camera during each measurement by the Corvis ST. The deformation amplitude (DA) and other parameters (e.g., pachy apex, intraocular pressure, 1st A time, highest concavity-time, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, curvature radius highest concavity, curvature radius normal, Vin, Vout) measured by the corvis ST were correlated with age. 3) Prospective study: 151 eyes of 127 patients were underwent cataract surgery. 75 eyes of 65 patients were with femtosecond laser-assisted (FS)(Alcon Len Sx, Aliso Viejo,USA) and 76 eyes of 62 patients with standard phacoemulsification (SP) (Alcon Infinit, FortWorth, USA). 4) Case Report. RESULTS: 1) About the first study: Mean patient age was 35.80 ± 12.83 years (range: 21.07 to 78.84 years). Mean central corneal thickness was 547.50 ± 32.00 ?m (range: 490 to 647 ?m) and mean spherical equivalent refraction was -3.29 ± 3.69 diopters (range: -9.50 to +10.37 diopters). Mean deformation amplitude was 1.05 ± 0.08 mm (range: 0.91 to 1.26 mm). Highest concavity time was 18.38 ± 0.93 ms (range: 16.95 to 21.07 ms). Intraocular pressure was 16.43 ± 2.15 mm Hg (range: 11.50 to 21.0 mm Hg). First applanation time was 8.32 ± 0.33 ms (range: 7.53 to 9.12 ms) and second applanation time was 23.80 ± 0.44 ms (range: 22.76 to 24.95 ms). First applanation length (max) was 2.07 ± 0.38 mm (range: 1.20 to 3.10 mm) and second applanation length (max) was 2.37 ± 0.47 mm (range: 1.33 to 4.12 mm). Curvature radius highest concavity was 11.09 ± 2.06 mm (range: 7.58 to 15.98 mm) and curvature radius normal was 7.59 ± 0.67 mm (range: 6.82 to 11.02 mm). Velocity in was 0.21 ± 0.05 m/s (range: 0.16 to 0.72 m/s) and velocity out was -0.33 ± 0.07 m/s (range: - 0.72 to -0.20 m/s). Studied parameters were not associated with gender. 2) Mean patient age was 27.50 ± 6.30 years. The highest concavity-time was the only studied parameter statistically significantly correlated to age (i.e., p=0.04, rs=0.18). 3) In relation the surgery of cataract: In group of FS, 9 of 11 parameters derived from Corvis ST were statistically significant (ss). In group of SP, 7 of 11 parameters derived from Corvis ST were ss. Only the HC - time was statistically significant between two groups (FS;SP) with p = 0.0387. 4) Corneal OCT identified a deep meniscos-shaped Lasik flap, with a central thickness of a 392 ?m in the right eye, and a incomplete deep peripheral cut in the left eye with a thinner meniscos-shaped LASIK flap. CONCLUSIONS: 1) Eight of 11 ocular biomechanical metrics given by the CorVis ST were associated with central corneal thickness, but the influence of central corneal thickness on these measurements was low. 2) In healthy eyes, age and pressure or biomechanics as derived from the Corvis ST parameters were not associated with exception to highestconcavity-time, i.e., the time from starting until the highest concavity is reached. 3) The use of the femtosecond laser- assisted system for cataract surgery and standard phacoemulsification induzed changes of biomechanical properties of the cornea by Corvis ST. Only 1 of 11 parameters studied was different statistically in two groups. 4) Unilateral ectasia after LASIK may occur due to a thick flap which leads to biomechanical failure of the cornea
27

Comparação prospectiva e randomizada entre DisCo Visc e hidroxipropilmetilcelulose 2% durante a facoemulsificação / Prospective randomized comparison of DisCoVisc and 2% hydroxypropylmethilcellulose in phacoemulsification

Espindola, Rodrigo França de 16 October 2015 (has links)
INTRODUÇÃO: Comparar duas soluções viscoelásticas, ácido hialurônico 1,6%/sulfato de condroitina 4% (DisCoVisc®, Alcon Laboratórios, EUA) e hidroxipropilmetilcelulose 2% (HPMC, Ophthalmos, Brasil), com relação ao desempenho durante a facoemulsificação (FACO) e o implante de lente intraocular. MÉTODOS: Foi realizado um ensaio clínico randomizado, envolvendo 78 olhos (39 pacientes) submetidos à FACO bilateral, por um único cirurgião. Os pacientes foram randomizados para receber DisCoVisc ou HPMC no primeiro olho. O olho contralateral foi operado mais tarde recebendo a outra solução viscoelástica em todas as etapas da cirurgia. Examinadores mascarados realizaram as avaliações pré e pósoperatórias (5, 24 e 48 horas; 7 e 14 dias; 3 e 6 meses), incluindo a medida da pressão intraocular (PIO), espessura cornena central (ECC) e acuidade visual corrigida. A densidade endotelial foi realizada no pré-operatório e ao final do seguimento (6 meses). Variáveis intraoperatórias incluíram medidas da quantidade total de solução viscoelástica, tempo de ultrassom durante a FACO e tempo para a retirada completa da solução do olho. RESULTADOS: A densidade endotelial foi estatisticamente superior com DisCoVisc (2.214 ± 372 cel/mm2) do que com HPMC (2.032 ± 460 cel/mm2) ao final do seguimento (p = 0,001). Uma redução média de 7% e de 15%, respectivamente. Não houve diferença estatística entre as soluções viscoelásticas com relação a densidade da catarata (p = 0,363) e o tempo de ultrassom (p = 0,456). O tempo de aspiração da HPMC (0,22 ± 0,09 min) foi significativamente maior que o DisCoVisc (0,17 ± 0,06 min) (p = 0,001) e a quantidade de viscoelástico utilizada foi maior com a HPMC (1,35 ± 0,20 ml) do que com DisCoVisc (0,89 ± 0,11 ml) (p < 0,001). Não houve diferença estatisticamente significativa entre as soluções quanto a ECC e a PIO durante o seguimento. CONCLUSÕES: A densidade endotelial ao final do estudo foi significativamente maior com o uso de DisCoVisc, o que pode representar uma melhor proteção endotelial. Foi necessário uma menor quantidade de DisCoVisc e um tempo de aspiração menor durante a FACO com essa solução viscoelástica / INTRODUCTION: To compare two ophthalmic viscosurgical devices (OVDs), 1.6% hyaluronic acid/4% chondroitin sulfate (DisCoVisc®, Alcon Lab., USA) and 2% hydroxypropylmethylcellulose (HPMC, Ophthalmos, Brazil), in terms of their overall performance during phacoemulsification (PHACO) and intraocular lens implantation. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that underwent PHACO by the same surgeon. Patients were randomly assigned to receive DisCoVisc or HPMC on the first eye. The other eye was treated later and received the other OVD. Masked examiners measured intraocular pressure (IOP), central corneal thickness (CCT) and best-corrected visual acuity. The corneal endothelial cell density was measured at baseline and at 6 months postoperatively. Intraoperative variables include the total amount of the OVD, ultrasound and washout times. RESULTS: Corneal endothelial cell density was significantly higher with DisCoVisc (2.214 ± 372 cell/mm2) than HPMC (2.032 ± 460 cell/mm2) at the end of follow-up (p = 0.001). A mean reduction of 7% and 15%, respectively. There were no statistically significant differences between OVDs in terms of cataract density (p = 0.363) or ultrasound time (p = 0.456). Regarding washout time, it took longer to remove HPMC (0.22 ± 0.09 min) than DisCoVisc (0.17 ± 0.06 min) (p = 0.001), and the amount of viscoelastic material used was greater with HPMC (1.35 ± 0.20 ml) than DisCoVisc (0.89 ± 0.11 ml) (p < 0.001). There were no statistically significant differences between the two OVDs regarding CCT or IOP measurements at any point in time. CONCLUSION: The corneal endothelial cell loss was significantly less with DisCoVisc than HPMC, which can improve corneal endothelium protection. DisCoVisc was easier to remove after IOL implantation and fewer amounts were necessary during PHACO
28

Avaliação dos efeitos da variabilidade da pressão arterial sistêmica sobre a pressão de perfusão ocular e suas repercussões sobre o estresse oxidativo em retinas de ratos normotensos e hipertensos / Assessment of the effects of the variability of blood pressure on the ocular perfusion pressure and its effects on oxidative stress in normotensive and hypertensive rats

Castro, Emerson Fernandes de Sousa e 21 August 2014 (has links)
Introdução: A hipertensão arterial sistêmica (HAS) é uma doença que pode determinar lesões em diversos órgãos inclusive nos olhos. As doenças vasculares oculares constituem a grande maioria das causas de cegueira na atualidade e a HAS tem contribuição importante nesta estatística. A variabilidade da pressão arterial tem sido implicada na gênese de uma série de lesões de órgãos-alvo. Na tentativa de compreender melhor a patogênese das doenças vasculares oculares testamos a hipótese de que não apenas os efeitos da HAS, mas também a variabilidade da pressão arterial (PA) poderia determinar lesão de órgão-alvo (ocular). Materiais e Métodos: A desnervação sino-aórtica (DSA), um modelo experimental de aumento da variabilidade da pressão arterial foi utilizado nos experimentos. Foram obtidas medidas da pressão intraocular e a partir destas medidas, a pressão de perfusão ocular. Foram analisados marcadores de estresse oxidativo (8-OHdG e nitrotirosina),VEGF e receptores AT1 na retina de animais normotensos e hipertensos com e sem DSA aguda (12 e 24 horas) e crônica (10 semanas). Resultados: Os animais desnervados apresentaram aumento da variabilidade da PA sem modificar a PA basal e redução da sensibilidade do barorreflexo. Houve aumento da modulação simpática vascular e da pressão de perfusão ocular (PPO), nos animais hipertensos, com aumento adicional da PPO nos hipertensos e desnervados crônicos.Observou-seestresse oxidativo retiniano nos animais desnervados agudos e noshipertensos desnervados crônicos, além do aumento da expressão de receptores AT1 da Angiotensina II nos animais hipertensos. Os níveis de VEGF retinianos dos animais desnervados crônicos, apresentaram comportamento inverso aos níveis de Caspase-3. Conclusão: Tais resultados indicam que só a HAS, mas também a variabilidade da PA podem determinar variações na pressão de perfusão ocular, assim como também podem induzir dano oxidativo às células retinianas. Além disso, pode-se sugerir efeito neuroprotetor retiniano do VEGF / Introduction: High blood pressure (HBP) is a disease that can determine lesions in many organs including the eyes. The ocular vascular diseases constitute the vast majority of causes of blindness and hypertension has important contribution in this statistic. Blood pressure variability has been implicated in the genesis of a series of end-organ damage. In an attempt to better understand the pathogenesis of ocular vascular diseases, we hypothesized that not only the effects of hypertension, but also the variability of blood pressure (BPV) could determine target end-organ damage (ocular). Materials and Methods: Sino-aortic denervation (SAD), an experimental model of increased blood pressure variability was used in the experiments. The intraocular pressure measurements were performed and from these measurements the ocular perfusion pressure was estimated. Oxidative stress markers (8-OHdG and nitrotyrosine), VEGF and AT1 receptor in rat retinas were analyzed inacute and chronic hypertensive and normotensiveSAD rats and in controls. Results: Denervated animals showed increased BP variability without altering the basal BP, while presenting reduced baroreflex sensitivity.There was an increase in sympatheticvascular modulation and in OPP,in hypertensive animals, that was additionally in chronic denervated hypertensive animals.Acute denervated and chronic hypertensive denervated animals showed retinal oxidative stress as well as hypertensive animals presented increased expression of AT1 receptors of angiotensin II. The levels of retinal VEGF of chronically denervated animals showed inverse behavior of levels of Caspase-3 Conclusion: These results suggest that, apart from the arterial hypertension, BP variability not only determines changes in ocular perfusion pressure, but also induces oxidative damage to retinal cells. Furthermore, one can suggest retinal neuroprotective effect of VEGF
29

Comparação dos valores da pressão intraocular obtidos com diferentes tonômetros e suas correlações com dados biométricos oculares no glaucoma congênito / Comparison between intraocular pressure obtained with different tonometers and their correlations with biometric parameters in congenital glaucoma

Mendes, Marcio Henrique 01 November 2013 (has links)
OBJETIVOS: Comparar os valores da pressão intraocular (PIO), obtidos por intermédio do tonômetro de Perkins (TPK), tonômetro de contorno dinâmico Pascal (TCD) e Tono-Pen (TNP), confrontando-os com o tonômetro de aplanação de Goldmann (TAG), e correlacionar seus valores tonométricos com parâmetros biométricos oculares em pacientes portadores de glaucoma congênito primário. MÉTODOS: Estudo prospectivo, transversal, com inclusão de 46 pacientes (46 olhos) com diagnóstico de glaucoma congênito primário, com idades entre 12 e 40 anos, após obtenção do Termo de Consentimento Livre e Esclarecido. Todos os olhos estudados foram submetidos à tonometria ocular usando os tonômetros de Goldmann, de Perkins, o Tono-Pen e o tonômetro de contorno dinâmico Pascal. A ordem das tonometrias foi aleatória e o tonômetro de Goldmann foi adotado como padrão ouro. Os parâmetros biométricos estudados foram a curvatura (medida pela ceratometria), a espessura central da córnea (paquimetria), o diâmetro corneal (medido por meio de compasso cirúrgico) e o comprimento axial do olho foi obtido pela biometria ultrassônica. As distribuições dos parâmetros biométricos, assim como das tonometrias foram plotadas e analisadas conforme teste de Kolmogorov-Smirnov para aceitação de normalidade. O teste t de Student pareado para amostras independentes foi empregado para comparar as médias tonométricas de cada tonômetro com o padrão ouro. As correlações entre os parâmetros biométricos e as tonometrias foram realizadas através do coeficiente de correlação de Pearson e gráficos de regressão linear. O mesmo procedimento foi feito entre os parâmetros biométricos e as diferenças entre as três distintas tonometrias e a TAG. A concordância entre os tonômetros Perkins, Pascal e Tono-Pen e o de Goldamnn foi realizada pelo teste de concordância de correlação (CCC) e graficamente pelo método de Bland-Altman. O valor de corte de 2 mmHg foi adotado para avaliar a empregabilidade clínica desses tonômetros em pacientes semelhantes aos da amostra. RESULTADOS: O teste de Kolmogorov-Smirnov indicou aceitação da normalidade para todas as distribuições estudadas (TAG, TPK, TCD, TNP, Diâmetros corneal e axial, ceratometria média e paquimetria). Os momentos de correlação de Pearson empregados para realizar estudo das correlações entre os parâmetros biométricos e cada tonometria foram estatisticamente não significativos. As correlações entre os parâmetros biométricos e as diferenças entre tonometrias em relação ao TAG não apresentaram significância em sua maioria, sendo a única exceção a correlação moderada entre a diferença do TAG e o Tono-Pen versus a ceratometria média. No entanto, o coeficiente de determinação evidenciou influência modesta da ceratometria nessas diferenças (r² = 0,16; p = 0,004). O teste t de Student pareado demonstrou diferença significativa entre o TAG e o TP (p < 0,001). A diferença não foi significativa entre o TAG e o Pascal (p = 0.30), ou entre o TAG e o Tono-Pen (p = 0.68). Houve excelente concordância entre o TAG e o TP (CCC = 0,98; intervalo de confiança 95% (IC95%) = 0,97 - 0,99), já entre o TAG e o Pascal (CCC = 0,89; IC95% = 0,82 - 0,94) e entre o TAG e o Tono-Pen (CCC = 0,92; IC95% = 0,87 - 0,95). O gráfico tipo Bland-Altman TAG x Perkins demonstrou diferença média de 0,47 mmHg com intervalo de 95% (I95%) situado entre -0,98 e 1,92 mmHg. A dispersão das diferenças seguiu caráter aleatório. Os outros dois tonômetros também tiveram suas dispersões em caráter aleatório. TAG em relação ao tonômetro de Pascal apresentou diferença média de -0,3 mmHg (I95% = -4,2 a 3,6 mmHg). A diferença média do TAG em relação ao Tono-Pen foi de -0,1 mmHg (I95% = -3,7 a 3,5 mmHg). Em 21% dos pacientes, o tonômetro de Pascal apresentou diferenças maiores de 2 mmHg em relação ao TAG, ao passo que no Tono- Pen essa proporção foi de 17,3%, e o tonômetro de Perkins não apresentou em nenhum dos pacientes diferenças maiores que estes limites. CONCLUSÕES: A ceratometria, paquimetria e os diâmetros axial e corneal não se correlacionaram com a PIO obtida por meio do TAG, tonômetro de Perkins, Pascal ou Tono-Pen. As diferenças tonométricas entre TAG (padrão ouro) e os outros tonômetros também não se correlacionaram com esses parâmetros biométricos, com exceção da ceratometria média, que se correlacionou positiva e moderadamente com a diferença da PIO entre TAG e Tono-Pen. O tonômetro de Perkins apresentou concordância substancial com o TAG, já o Tono-Pen e o TCD apresentaram concordâncias moderadas, sendo a concordância do Tono-Pen maior que a do TCD / OBJECTIVES: To compare the values of intraocular pressure (IOP) obtained by Perkins tonometer (PKT), Pascal dynamic contour tonometer (DCT) and Tono-Pen (TP), comparing then with Goldmann applanation tonometry (GAT), analyzing their correlations with ocular biometric parameters in patients with primary congenital glaucoma. METHODS: Prospective and cross-sectional study, including 46 patients (46 eyes) diagnosed with primary congenital glaucoma, between 12 and 40 years old, after obtaining informed consent. Keratometry was performed, followed by Goldmann applanation tonometry, Perkins tonometry, DCT and TP. The order of tonometries was randomized. The Goldmann tonometer was adopted as the gold standard. Ultrasound pachymetry, ultrasound biometry and corneal diameter measurement with surgical compass were also performed. The distributions of biometric parameters, as well as the tonometries were plotted and analyzed using Kolmogorov-Smirnov for acceptance of normality. Paired Student\'s t test for independent samples was used to compare the means of each tonometry with the gold standard. The correlations between biometric parameters and tonometries were performed by Pearson\'s product moment correlation coefficient and linear regression plots. The same procedure was done between biometric parameters and the differences between the three distinct tonometries and Goldmann tonometry. The agreement between tonometers and the GAT was performed through concordance correlation coefficient (CCC) and graphically by the Bland-Altman method. End point of 2 mmHg was adopted to evaluate clinical employability of these tonometers in patients with similar conditions. RESULTS: The Kolmogorov-Smirnov indicated acceptance of normality for all distributions studied (GAT, PKT, DCT, TP, corneal diameter, axial length, keratometry and pachymetry). All the Pearson´s product moment correlation coefficients between biometric parameters and each tonometry were not significant. The correlations between the biometric parameters and the differences between tonometries compared to the gold standard were not significant in most cases. The only exception was a positive and moderate correlation between the difference of the GAT and Tono-Pen versus the keratometry. The determintation coefficient revealed a considerable, but no large influence of K on the differences between GAT and Tono-Pen (r² = 0.16; p = 0.004). Student\'s paired t test showed a significant difference between GAT and PT (p < 0.001). The difference was not significant between the GAT and Pascal (p = 0.30), or between the GAT and Tono-Pen (p = 0.68). There was excellent agreement between GAT and PT (CCC = 0.98, 95% confidence interval (95% CI) = 0.97 to 0.99), as between GAT and Pascal (CCC = 0.90, 95% CI = 0.82 to 0.94) and between GAT and Tono-Pen (CCC = 0.92, 95% CI = .87 to .95). Bland-Altman plot GAT x Perkins showed a mean difference of 0, 47 mmHg with 95% CI located between -0.98 and 1.92 mmHg. The distribution of the IOP differences was aleatory. The other two differences` distributions also had aleatory characteristics. When comparing GAT with Pascal, the mean difference was -0.3 mmHg (95% CI = -4.2% to 3.6 mmHg). Mean difference between GAT and Tono-Pen was -0.1 mmHg (95% CI = -3,7 to 3.5 mmHg). Pascal tonometer showed a difference greater than 2 mmHg comparing to GAT in 21% of the patients, while with Tono-Pen this ratio was 17.3% and the Perkins tonometer did not present in any patient differences greater than these limits. CONCLUSIONS: The keratometry, pachymetry, corneal diameter and axial length did not correlate with IOP obtained by GAT, Perkins tonometer, Tono-Pen or Pascal. The differences between GAT (gold standard) and the other tonometers also did not correlate with these biometric parameters, with the exception of corneal curvature, which was positive and moderately correlated with the difference in IOP between GAT and Tono-Pen. GAT and Perkins tonometer showed substantial agreement, although Tono-Pen and DCT showed moderate agreement with GAT. The concordance obtained with Tono-Pen was higher than the concordance obtained with DCT
30

Comparação prospectiva e randomizada entre DisCo Visc e hidroxipropilmetilcelulose 2% durante a facoemulsificação / Prospective randomized comparison of DisCoVisc and 2% hydroxypropylmethilcellulose in phacoemulsification

Rodrigo França de Espindola 16 October 2015 (has links)
INTRODUÇÃO: Comparar duas soluções viscoelásticas, ácido hialurônico 1,6%/sulfato de condroitina 4% (DisCoVisc®, Alcon Laboratórios, EUA) e hidroxipropilmetilcelulose 2% (HPMC, Ophthalmos, Brasil), com relação ao desempenho durante a facoemulsificação (FACO) e o implante de lente intraocular. MÉTODOS: Foi realizado um ensaio clínico randomizado, envolvendo 78 olhos (39 pacientes) submetidos à FACO bilateral, por um único cirurgião. Os pacientes foram randomizados para receber DisCoVisc ou HPMC no primeiro olho. O olho contralateral foi operado mais tarde recebendo a outra solução viscoelástica em todas as etapas da cirurgia. Examinadores mascarados realizaram as avaliações pré e pósoperatórias (5, 24 e 48 horas; 7 e 14 dias; 3 e 6 meses), incluindo a medida da pressão intraocular (PIO), espessura cornena central (ECC) e acuidade visual corrigida. A densidade endotelial foi realizada no pré-operatório e ao final do seguimento (6 meses). Variáveis intraoperatórias incluíram medidas da quantidade total de solução viscoelástica, tempo de ultrassom durante a FACO e tempo para a retirada completa da solução do olho. RESULTADOS: A densidade endotelial foi estatisticamente superior com DisCoVisc (2.214 ± 372 cel/mm2) do que com HPMC (2.032 ± 460 cel/mm2) ao final do seguimento (p = 0,001). Uma redução média de 7% e de 15%, respectivamente. Não houve diferença estatística entre as soluções viscoelásticas com relação a densidade da catarata (p = 0,363) e o tempo de ultrassom (p = 0,456). O tempo de aspiração da HPMC (0,22 ± 0,09 min) foi significativamente maior que o DisCoVisc (0,17 ± 0,06 min) (p = 0,001) e a quantidade de viscoelástico utilizada foi maior com a HPMC (1,35 ± 0,20 ml) do que com DisCoVisc (0,89 ± 0,11 ml) (p < 0,001). Não houve diferença estatisticamente significativa entre as soluções quanto a ECC e a PIO durante o seguimento. CONCLUSÕES: A densidade endotelial ao final do estudo foi significativamente maior com o uso de DisCoVisc, o que pode representar uma melhor proteção endotelial. Foi necessário uma menor quantidade de DisCoVisc e um tempo de aspiração menor durante a FACO com essa solução viscoelástica / INTRODUCTION: To compare two ophthalmic viscosurgical devices (OVDs), 1.6% hyaluronic acid/4% chondroitin sulfate (DisCoVisc®, Alcon Lab., USA) and 2% hydroxypropylmethylcellulose (HPMC, Ophthalmos, Brazil), in terms of their overall performance during phacoemulsification (PHACO) and intraocular lens implantation. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that underwent PHACO by the same surgeon. Patients were randomly assigned to receive DisCoVisc or HPMC on the first eye. The other eye was treated later and received the other OVD. Masked examiners measured intraocular pressure (IOP), central corneal thickness (CCT) and best-corrected visual acuity. The corneal endothelial cell density was measured at baseline and at 6 months postoperatively. Intraoperative variables include the total amount of the OVD, ultrasound and washout times. RESULTS: Corneal endothelial cell density was significantly higher with DisCoVisc (2.214 ± 372 cell/mm2) than HPMC (2.032 ± 460 cell/mm2) at the end of follow-up (p = 0.001). A mean reduction of 7% and 15%, respectively. There were no statistically significant differences between OVDs in terms of cataract density (p = 0.363) or ultrasound time (p = 0.456). Regarding washout time, it took longer to remove HPMC (0.22 ± 0.09 min) than DisCoVisc (0.17 ± 0.06 min) (p = 0.001), and the amount of viscoelastic material used was greater with HPMC (1.35 ± 0.20 ml) than DisCoVisc (0.89 ± 0.11 ml) (p < 0.001). There were no statistically significant differences between the two OVDs regarding CCT or IOP measurements at any point in time. CONCLUSION: The corneal endothelial cell loss was significantly less with DisCoVisc than HPMC, which can improve corneal endothelium protection. DisCoVisc was easier to remove after IOL implantation and fewer amounts were necessary during PHACO

Page generated in 0.0835 seconds