• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • Tagged with
  • 42
  • 42
  • 15
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo da eficiência de um detector HPGe por métodos semiempíricos e experimental

Marcio Drumond Costa Ferreira 23 August 2012 (has links)
Nenhuma / A espectrometria gama é uma técnica que proporciona informações diversas em uma única análise, além de ser rápida e não destrutiva. Por meio de um detector de radiação acoplado a um sistema eletrônico de aquisição de dados, a técnica identifica os radionuclídeos emissores gama em uma amostra com radioatividade natural ou induzida, bem como fornece informações para calcular as suas atividades, a partir do registro e análise do espectro gama. A eficiência é um dos principais parâmetros a ser considerado quando se trabalha com detectores de radiação gama. Seu conhecimento possibilita uma melhor exatidão na quantidade de quantuns de radiação que o detector pode registrar dentre o total que emerge da fonte ou da amostra em estudo. A eficiência pode ser determinada experimentalmente, por métodos teóricos e semiempíricos. Usualmente, a determinação por método experimental é a mais exata, porém exige a aquisição de mais dados, o que torna o procedimento mais trabalhoso. Por sua vez, os métodos teóricos e os semiempíricos são muito menos laboriosos, apesar dos riscos de apresentarem maiores incertezas. Neste trabalho, foi realizado um estudo comparativo para verificar se as equações de eficiência determinadas por métodos semiempíricos e experimental teriam desempenhos similares na determinação das concentrações elementares da amostra de referência IAEA/Soil7, em geometria puntual e não puntual, irradiadas no reator de pesquisa TRIGA MARK I IPR-R1. Por métodos semiempíricos, foram aplicados os programas KayZero for Windows, V. 2.42 específico para cálculo de concentração elementar no método k0 de Ativação Neutrônica e o ANGLE V3.0 desenvolvido para cálculo de eficiência de detectores semicondutores para diversas geometrias. Os resultados indicaram, por meio de avaliação estatística, que as eficiências determinadas experimentalmente e por métodos semiempíricos são similares e igualmente eficazes tanto para a amostra puntual quanto para a não puntual. As diferenças observadas nos resultados das concentrações elementares foram relacionadas às correções aplicadas pelo programa e não consideradas quando se usa a planilha eletrônica e não devido às eficiências determinadas. Este estudo mostrou também que o programa KayZero for Windows analisa e considera como puntual amostras com massa cinco vezes maior que a massa das amostras usualmente analisadas, o que expande o campo de aplicação do programa. / Gamma spectrometry is a technique that provides a piece of information on a sample in one measurement, in a fast and non destructive assay. Such technique identifies gamma emitter radionuclides in natural and induced radioactivity, using a radiation detector linked to an electronic system in order to acquire the data and gamma spectra. To determine the full energy peak efficiency of High-Purity Germanium detector is important for gamma-ray spectrometry experiments. The efficiency of a detector is proportionality constant, which relates the activity of the source being counted and the number of counts observed. This efficiency can be determined applying experimental methods, using theoretical and semi empirical methods. Usually, the determination via an experimental procedure is more accurate, however, it is necessary more data acquisition that makes the procedure more tiring. On the other hand, the theoretical and semi empirical methods are less laborious procedures, despite the risks of higher uncertainties. This comparative study was carried out in order to verify whether the full energy peak efficiency curves determined by experimental and semi empirical methods, would present a similar performance on elemental concentration of reference material IAEA/Soil7, prepared in punctual and non-punctual geometries, and irradiated in the TRIGA MARK I IPR-R1 research reactor. It was applied were applied the KayZero for Windows, V. 2.42 a specific software for elemental concentration determination in the k0-stardadization neutron activation analysis - and ANGLE V3.0 specific method to determine semi conductor detectors gamma efficiencies for several sample geometries. Based on statistical tests u-score and Relative Tendency - the results pointed out for two types of sample geometries, the efficiencies determined experimentally and by semi empirical methods are similar, which were fitted well and worked properly. The deviations observed in the results were related to corrections made by the KayZero for Windows software and didnt apply when the values were calculated using the spread sheet and not related to the efficiency curves themselves. Additionally, it was evidenced that KayZero for Windows software is able to analyze a non-punctual sample, with mass 5 times higher that the usual size, as it were punctual. It points out the versatility of the software and expands the application field.
32

Avaliação da exposição ocupacional do cristalino em radiologia intervencionista

Flavia Luiza Soares Borges 26 August 2013 (has links)
Estudos recentes têm indicado o aumento da incidência de opacidade do cristalino para baixas doses de radiação. Considerando os dados epidemiológicos, a Comissão Internacional de Proteção Radiológica (ICRP) emitiu um comunicado que mudou o limite de dose absorvida para o cristalino. A publicação também recomenda a redução dos limites de dose equivalente para os indivíduos ocupacionalmente expostos, agora considerado de 20 mSv em um ano, em média, ao longo de cinco anos. Como consequência, algumas exposições planejadas requerem o uso de dosímetro adicional para estimar a dose no cristalino em profissionais. Este é o caso dos profissionais de radiologia intervencionista. Atualmente, as normas nacionais e internacionais, carecem de uma metodologia específica para a dosimetria em Hp(3). A recomendação ICRP provocou o debate sobre a adequação da grandeza equivalente de dose e sobre os métodos para as suas medições. Os objetivos deste trabalho foram: estudar a metodologia para a calibração de dosímetros pessoais em Hp(3) e monitorar profissionais durante os procedimentos de radiologia intervencionista. Diretrizes internacionais e recomendações da literatura recente foram adotadas para os procedimentos de calibração e testes. Para calibração, o sistema de dosimetria, que consiste em um suporte e um detector termoluminescente LiF:Mg,Cu,P (TLD-100H), foi exposto a radiações de referência em um fantoma cilíndrico preenchido com água, que se simulou a cabeça. Os fatores de calibração foram determinados para o potencial de tubo 20-150 kV da série 4037 estreito espectro de ISO. A monitoração individual foi realizada durante procedimentos vasculares de angioplastia e angiografia. Os resultados mostraram-se satisfatórios comparados à literatura. / Recent studies have indicated the increase of the incidence of lens opacities for low radiation doses. Considering epidemiological data, the International Commission on Radiological Protection (ICRP) issued a statement that changed the absorbed dose threshold for the eye lens. The statement also recommends a reduction in the dose limits to the eye lens for occupationally exposed persons; now it is considered to be 20 mSv in a year averaged over five years. As consequence, some planned exposures require the use of additional dosemeter for estimating eye lens dose in professionals; it is the case of the staff in interventional radiology. Nowadays, in the national and international standards there is a lack of specific methodology for eye lens dosimetry. The ICRP recommendation raised the debate on the adequacy of dose equivalent quantities of radiological protection and on the methods for their measurements. The objectives of this research were to study the methodology for calibrating personal dosemeters in Hp (3) and monitor professionals during interventional radiology procedures. International guidelines and recent literature were adopted for the calibration procedures and tests. For calibration, the dosimetric system, consisting of a holder and thermoluminescent detector LiF:Mg,Cu,P (TLD-100H), was exposed to standard radiation fields on a cylindrical water phantom that simulated the head. The calibration coefficients of the dosimetric system were determined for tube potential from 20 to150 kV of the ISO 4037 narrow spectrum series. The individual monitoring was performed during vascular procedures - angiography and angioplasty. The results were satisfactory were compared to the literature
33

Estudo de desempenho de sistemas de visualização de imagens mamográficas correlacionados com qualidade de imagem / Study of the performance of visualization mammographic systems images correlated with image quality

Danielle Soares Gomes 03 June 2014 (has links)
Para as análises de imagens mamográficas, médicos radiologistas fazem uso de monitores médicos especializados, capazes de proporcionar laudos seguros, uma vez que devem oferecem resolução adequada, níveis corretos de luminância e contraste dentro do padrão DICOM - Digital Imaging and Communications in Medicine (Comunicação de Imagens Digitais na Medicina). Este trabalho teve como objetivo avaliar a qualidade dos monitores específicos para mamografia digital, através de testes propostos pelo Report N 3 da American Association of Physicists in Medicine AAPM usando medidores calibrados de luminância (fotômetro) e padrões TG18 em testes quantitativos e qualitativos. Avaliou-se as condições de luz ambiente e outros indicadores básicos de desempenho, como, distorção geométrica, ruído, resolução, reflexão, uniformidade da luminância, o cumprimento resposta contraste de luminância para padrão DICOM e padrão anatômico das mamas. Em resposta, o teste que mais apresentou não conformidade foi à variação excessiva com o padrão de resposta contraste DICOM Grayscale Standard Display Function (GSDF), apresentando não conformidade em (100%) dos monitores analisados. Nos demais testes, todos os monitores de 5MP e o de 3MP apresentaram conformidade nos parâmetros avaliados. Em uma ação corretiva para as não conformidades, indica-se a realização de calibrações e procedimentos de verificação de controle de qualidade feitas por profissionais capacitados ou orientados. / For the analysis of mammographic images, radiologists make use of specific medical monitors, able to provide insurance reports, as they offer appropriate resolution, correct levels of luminance and contrast within the standard DICOM - Digital Imaging and Communications in Medicine (Communication Images digital in Medicine). This study aims to evaluate the quality of specific monitors for digital mammography, by testing the calibrated luminance meters (photometer) and TG18 standards in quantitative and qualitative methods proposed by Report No. 3 of American Association of Physicists in Medicine AAPM. It was evaluated the ambient light conditions and other basic performance indicators, such as, the as geometric distortion, noise, resolution, reflection, luminance uniformity, contrast luminance response compliance to DICOM standard and anatomical pattern of the breasts. The results showed that non-compliance test fails when visualizing low-contrast objects (100% of monitors analyzed) in the response pattern contrast DICOM Grayscale Standard Display Function (GSDF). For the other tests, all monitors of 5 and 3MPixel presented in agreement to the evaluated parameters. For a further corrective action for instance, non-compliance, it may be indicate to perform calibrations and verification of quality control developed by trained or oriented professionals.
34

Avaliação da dose absorvida nas mamas em exames de tomografia computadorizada multicorte para protocolo clínico de troboembolismo pulmonar: determinação do risco de câncer radioinduzido / Evaluation of absorbed dose in breast in multislices computed tomography exams for clinic protocol of pulmonary thromboembolism: radiation induced cancer risk determination

Katiane Costa do Carmo 26 June 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A introdução dos equipamentos de Tomografia Computadorizada Multicorte (MDTC) no Brasil tornou-se uma ferramenta fundamental para detecção das patologias torácicas, como o tromboembolismo pulmonar (TEP). O crescimento contínuo da utilização deste procedimento como meio diagnóstico tem contribuído significativamente para o aumento da dose de radiação, especialmente nas mamas, que embora não sejam de interesse diagnóstico, são diretamente irradiadas. O objetivo deste estudo foi avaliar a dose absorvida nas mamas de pacientes submetidas a exames de TEP e estimar o risco de câncer radioinduzido. Foram realizados testes de linearidade e reprodutibilidade do kerma no ar para avaliar o desempenho dos tomógrafos utilizados nas avaliações deste estudo. O estudo foi desenvolvido em seis tomógrafos instalados na Cidade de Belo Horizonte. As tecnologias de MDTCs avaliadas foram de 4, 16, 64 e 128 canais. A medição de dose foi feita como dosímetros termoluminescentes (100H). As doses absorvidas variaram entre 11,71,6 mGy e 2,720,24 mGy considerando todos os tamanhos de mamas e todos os tomógrafos aprovados nos testes de desempenho. Em quatro dos seis tomógrafos avaliados, as doses absorvidas nos três tamanhos de mamas, não apresentaram diferenças estatisticamente significativas. Porém, o avanço tecnológico em tomografia possibilitou uma diminuição na dose oferecida ao paciente. Há uma tendência de diminuição de dose de radiação com o aumento do número de detectores. As metodologias das ICRPs 60 e 103 subestimaram o risco radioinduzido em mulheres abaixo dos 50 anos. Já a metodologia BEIR VII mostrou ser uma boa opção de estimativa de risco, pois considera além de outros fatores, a idade do paciente, e como mostra este estudo, o risco de indução de câncer é maior em mulheres jovens. Os valores de doses absorvidas e riscos estimados apresentados neste trabalho podem servir de referência para estudos de otimização nestes tomógrafos, reduzindo consequentemente, o risco de câncer radioinduzido nas mamas, em pacientes submetidas a diagnóstico de TEP. / The introduction of Multi Slices Computed Tomography (MSCT) in Brazil has become a fundamental tool for thoracic disease detection, like Pulmonary Thromboembolism (PTE). The continuous growth of this procedure has significantly contributed for increase of the radiation doses, especially in breast, that are directly irradiated, although its not of diagnostic interest. The target of this study was to evaluate the absorbed dose in breast using an anthropomorphic phantom submitted to PTE exams to estimate the radiation induced cancer risk. Linearity and Reproducibility tests were realized to evaluate the performance of six tomograph used in this study, installed in Belo Horizonte city. The MSCT technologies evaluated were 2, 4, 16, 64 and 128 channels. The absorbed dose was measured with thermoluminescent dosimeters, model 100H. The absorbed doses vary between 11,71,6 mGy and 2,720,24 mGy considering all the sizes of breasts e all tomographs approved in performance tests. In four of six tomographs evaluated, the absorbed doses in three breasts sizes dont show differences statistically significant. But the technological advance in tomography enable a decrease in offered patient dose. Theres a tendency of reduction in the radiation dose with the increase of the detectors number. The methodologies of ICRPs 60 and 103 underestimated radiation induced risk in women under 50 years. Otherwise, the BEIR VII methodology shows to be a good option to risk estimate, because, between other factors, also considers patient age and, as shown in this study, the cancer induction risk is bigger in young women. The values of absorbed doses and estimated risks shown in this work can serve like reference for optimization studies in these tomographs, reducing, consequently, the radiation induced cancer risk in brests of patients submitted to PET diagnosis.
35

Protocolo experimental de testes de desempenho e dosimetria para tomossíntese digital de mama / Experimental protocol of performance tests and dosimetry for digital breast tomosynthesis

Bruno Beraldo Oliveira 06 October 2014 (has links)
Nenhuma / O sistema de tomossíntese digital de mama (Digital Breast Tomosynthesis, DBT) é uma modalidade de imagem emergente que fornece informações estruturais quase tridimensionais (3D) da mama. Este sistema possui um grande potencial para substituir ou complementar a mamografia padrão no diagnóstico do câncer de mama. A melhoria na diferenciação de tecidos normais e massas suspeitas é uma das principais vantagens do sistema DBT, que proporciona uma redução das sobreposições dos tecidos, principal problema da mamografia. No Brasil, os testes de desempenho e a dosimetria para mamógrafos convencionais são estabelecidos pela Portaria n 453/98 do Ministério da Saúde e pela Agência Nacional de Vigilância Sanitária. Porém, não há nenhum protocolo nacional que estabeleça os testes para o controle de qualidade de equipamentos digitais. A proposta deste trabalho foi investigar os resultados dos testes de desempenho e da dosimetria de um mamógrafo que utiliza o sistema DBT a fim de elaborar um documento que contenha testes de qualidade e o procedimento adequado de dosimetria para avaliar fisicamente estes equipamentos. Para determinar o adequado desempenho do mamógrafo, foi avaliada a estrutura do equipamento através dos testes de força e alinhamento da bandeja de compressão. Para avaliar o detector, foram realizados testes de linearidade e uniformidade da sua resposta. A fim de verificar a imagem produzida, o mamógrafo foi submetido aos testes de ruído, resolução espacial e qualidade da imagem utilizando objetos simuladores. Por fim, foi realizada a dosimetria do equipamento visando à otimização do procedimento. A otimização significa manter o nível de radiação tão baixo quanto razoavelmente exequível, considerando a qualidade da imagem, para proporcionar um diagnóstico preciso. A fim de garantir a confiabilidade dos resultados de dosimetria, os equipamentos utilizados foram submetidos a testes de fuga, repetibilidade, reprodutibilidade e dependência angular. Os resultados dos testes de desempenho realizados no equipamento com sistema DBT estavam em conformidade com a maioria dos valores de referência estabelecidos. Considerando as incertezas nas medições, todos os valores calculados na dosimetria estavam de acordo com os níveis de referência adotados internacionalmente. Este trabalho contribuiu para estabelecer o procedimento adequado dos testes de controle de qualidade e dosimetria em mamógrafos que utilizam o sistema DBT. A metodologia e os resultados obtidos são importantes, pois fazem parte de um documento pioneiro para avaliação destes equipamentos. / The Digital Breast Tomosynthesis (DBT) system is an emerging image modality that provides almost three-dimensional (3D) structural informations of the breast. This system has a great potential to replace or complement the standard mammography in the diagnosis of the breast cancer. The improvement in differentiation of normal tissues and suspicious masses is one of the main advantages of the DBT system, which provides a tissue overlap reduction, the main problem of mammography. In Brazil, the performance tests and dosimetry for analogic mammography units are established by the Ministry of Health Ordinance n 453/98 and the National Health Surveillance Agency. However, there is no national protocol establishing tests for the quality control of digital equipments. The purpose of this study was to investigate performance and dosimetry results of a mammography unit that uses the DBT system to elaborate a document that contains quality tests and the proper dosimetry procedure to evaluate these equipments physically. For the determination of the adequate performance of the mammographic unit, the structure of this equipment was evaluated through tests of strength and alignment of the compression paddle. For the detector assessment, tests of linearity and uniformity of its response were performed. In order to verify the image produced, the mammographic unit was submitted to noise, spatial resolution and image quality tests using phantoms. Finally, the dosimetry of this equipment was performed in order to optimize the procedure. The optimization means to maintain the level of radiation as low as reasonably achievable, considering the image quality to provide an accurate diagnosis. The equipments used were submitted to leakage current, repeatability, reproducibility and angular dependence tests to ensure the reliability of dosimetry results. Results of performance tests performed in the equipment with DBT system were in accordance with the most of reference values established. Considering the uncertainties in the measurements, all calculated values in dosimetry were in agreement with the reference levels adopted internationally. This work contributed to establish the proper procedure of quality control tests and dosimetry in mammographic units that use DBT systems. The methodology and results obtained are important because they are part of a pioneer document to evaluate these equipments.
36

Metodologia para geração de modelos de mama com distribuição espacial de tecido glandular / New method for generating breast models featuring glandular tissue spatial distribution

Lucas Paixão Reis 10 April 2015 (has links)
A mamografia é a principal técnica radiográfica utilizada para imagens das mamas. A mama é um órgão radio-sensível e existe um risco de câncer induzido pela radiação associado com a mamografia. A dose glandular média (DG) é a grandeza dosimétrica aceita para caracterizar o risco de câncer induzido pela radiação. Estudos anteriores concluíram que a DG depende não somente do conteúdo glandular, mas também da distribuição do tecido glandular dentro da mama. Neste trabalho, é proposto um novo método para a geração de modelos computacionais de mama com tecido epitelial e distribuição espacial do tecido glandular de pacientes submetidos a exames de mamografia digital. Cento e setenta modelos computacionais de mama com diferentes glandularidades foram simulados e os resultados foram comparados com valores de coeficientes de conversão para DG recomendados. As diferenças encontradas sugerem que os coeficientes de conversão recomendados internacionalmente podem superestimar a dose glandular média para mamas menos densas e subestimar a dose glandular média para as mamas mais densas. A metodologia descrita neste trabalho constitui uma ferramenta poderosa para a dosimetria em mamografia, principalmente para estudos de risco. / Mammography is the main radiographic technique used for breast imaging. A major concern with mammographic imaging is the risk of radiation-induced breast cancer due to the high sensitivity of breast tissue. The mean glandular dose (DG) is the dosimetric quantity widely accepted to characterize the risk of radiation induced cancer. Previous studies have concluded that DG depends not only on the breast glandular content but also on the spatial distribution of glandular tissue within the breast. In this work, a new method for generating breast models featuring skin composition and glandular tissue distribution from patients undergoing digital mammography is proposed. A hundred and seventy breast models with different breast glandularity were simulated and the results were compared with those obtained from recommended DG conversion factors. The results show that the internationally recommended conversion factors may be overestimating the mean glandular dose to less dense breasts and underestimating the mean glandular dose for denser breasts. The methodology described in this work constitutes a powerful tool for breast dosimetry, especially for risk studies.
37

Aplicação clínica da ultra-sonografia craniana com doppler em crianças prematuras de muito baixo peso

Gabriel, Marta Lúcia 07 April 2010 (has links)
Made available in DSpace on 2016-01-26T12:51:24Z (GMT). No. of bitstreams: 1 martagabriel_dissert.pdf: 5511768 bytes, checksum: 5fac42af6982c753eff37d2c54f3fd17 (MD5) Previous issue date: 2010-04-07 / Transcranial Doppler sonography is the technique more designate to detect intracranial hemorrhage (ICH) and periventricular leukomalacia (PVL) among preterm. This technique evidence the most important cerebral arteries, mainly arteries the circle of Willis, obtaining blood flow arteries resistance index (RI), becoming upset in cranial hemorrhage and hypoxic-ischemic injuries. Objectives: 1. Investigate the clinical application of Doppler sonography in detection of cerebral lesions in very low birth weight neonates. 2. Evaluate the prognosis considering severity and death according to the presence of changes in cerebral arteries detected by Doppler in these neonates. Casuistics and Methods: A total of 50 preterm infants with gestational age varying between 29 and 32 weeks (30.8  1.5 weeks) and birth weigh 550 to 1.500g (1.179  288g) were submitted to four transcranial Doppler sonography during the intervals between 1st to 5th day of life, 10th to 17th, 18th to 30th, and 30th to 44th days of life. The preterm was submitted to the anterior and transtemporal fontanelle technique with asepsis care of equipment and operator. Results: Cerebral lesions in 16 (32%) preterm, 11 (22%) cases of intracranial hemorrhage, 4 (8%) of periventricular leukomalacia, and 1(2%) of cerebral toxoplasmosis were detected. The study with Doppler demonstrated that the value of RI varied according to the time of performing exam. The mean value of RI in the anterior, middle, and posterior cerebral arteries of preterm with intracranial hemorrhage (n = 11) increased of the first to third exam. There was a statistically significant difference among mean values of RI of the anterior and posterior cerebral arteries (p = 0.001 and p = 0.043, respectively) of preterm without cerebral lesions and with ICH only the first exam. Conclusions: The transcranial Doppler sonography in very low birth weigth neonates is useful in detection of cerebral lesions as intracranial hemorrhage, periventricular leukomalacia, and cerebral toxoplasmosis. Changes of RI of the anterior, middle, and posterior cerebral arteries detected by Doppler, although nonpredictor of death, are related with severity of the clinical presentation in these neonates. / O ultrassom craniano (USC) com Doppler é o exame mais indicado paradetectar hemorragias intracranianas (HIC) e leucomalácia peri-ventricular (LPV) em prematuros. A técnica com Doppler demonstra os mais importantes ramos da vasculatura cerebral, notadamente as artérias principais do Polígono de Willis, determinando índice de resistência (IR) do fluxo sangüíneo nessas artérias, que pode estar alterado em sangramentos cranianos e eventos hipóxico/isquêmicos. Objetivos: 1. Investigar a aplicação clínica da ultra-sonografia craniana com Doppler na detecção de alterações cerebrais em crianças prematuras de muito baixo peso. 2. Avaliar o prognóstico, considerando gravidade e óbito, de acordo com presença de alterações em artérias cerebrais detectadas por Doppler nesses prematuros. Casuística e Método: Foram estudadas prospectivamente 50 crianças prematuras, com a idade gestacional variando entre 29 e 32 semanas (30,8  1,5 semanas) e peso ao nascimento de 550 a 1.500 g (1.179  288g). Todas foram submetidas a quatro exames de USC com Doppler, sendo o primeiro entre o 1º e 5º dia de vida, o segundo entre 10º e 17º, o terceiro entre 18º e 30º e o quarto entre 30º e 44º dia de vida. Os pacientes foram submetidos à técnica transfontanela anterior e transtemporal, com todos os cuidados em assepsia do aparelho e operador. Resultados: Foram detectadas alterações cerebrais em 16 (32%) crianças, sendo 11 (22%) casos de HIC, 4 (8%) de LPV e 1 (2%) de toxoplasmose cerebral. O estudo com Doppler apresentou valores do índice de resistência (IR), que variaram dependendo da época da realização dos exames. O valor médio do IR nas artérias cerebrais anterior, média e posterior das crianças com HIC (n = 11) aumentou do primeiro ao terceiro exame. Houve diferença estatisticamente significante entre valores médios de IR das artérias cerebrais anterior e posterior (p=0,001 e p=0,043, respectivamente) de crianças sem alterações cerebrais e com HIC apenas no primeiro exame. Conclusões - A ultrassonografia craniana com Doppler em RN prematuras de muito baixo peso é de grande valia na detecção de alterações cerebrais como hemorragia intracraniana, leucomalácia periventricular e toxoplasmose cerebral. Alterações no IR das artérias cerebrais anterior, média e posterior detectadas pelo Doppler, embora não preditoras de morte, estão relacionadas com a gravidade do quadro clínico em crianças prematuras de muito baixo peso.
38

A introdução da radiologia na Bahia: das primeiras lições na Faculdade de Medicina à criação de uma disciplina (1897-1974)

Barp, Ediana 10 November 2006 (has links)
Made available in DSpace on 2016-04-28T14:16:29Z (GMT). No. of bitstreams: 1 HCS - Ediana Barp.pdf: 1212614 bytes, checksum: f692355687de8e2df50a1ea2fb94288a (MD5) Previous issue date: 2006-11-10 / This research describes the process formation and structuring of a discipline of the medicine course, the radiology, since the moment of the arrival of a apparrel ray X in the medicine university of the Bahia to the moment of the creation of a discipline. We analyze how the Radiology was taught in many disciplines of the courses of the medicine, pharmacy, odontology and obstetrics, delimiting the historical course of the Radiology in the Bahia. We have established for our research the period betweem the 1897, moment of the arrival of a apparrel X ray in the medicine university of the Bahia , and 1974, after the Dr. Itazil Benício dos Santos have been approved in contest for professor of radiology of the Federal University of the Bahia / Esta pesquisa descreve o processo de formação e estruturação de uma disciplina do curso médico, a Radiologia, desde o momento da chegada de um aparelho de raios X na Faculdade de Medicina da Bahia até o momento da criação de uma disciplina. Analisamos o ensino de radiologia nas diferentes cadeiras dos cursos de Medicina, Farmácia, Odontologia e Obstetrícia, buscando delimitar o percurso histórico da Radiologia na Bahia. Dessa forma, estabelecemos o período para esta pesquisa entre os anos de 1897, momento da chegada de um aparelho de raios X na Faculdade de Medicina da Bahia, a 1974 após a aprovação do Dr. Itazil Benício dos Santos no concurso para professor titular de Radiologia da Universidade Federal da Bahia (UFBA)
39

Radioterapia parcial e acelerada de mama utilizando braquiterapia de alta taxa de dose para pacientes com est?dio inicial de c?ncer de mama: an?lise uni-institucional

Massarotto, Ana Carolina 15 December 2017 (has links)
Submitted by SBI Biblioteca Digital (sbi.bibliotecadigital@puc-campinas.edu.br) on 2018-02-07T13:06:22Z No. of bitstreams: 1 ANA CAROLINA MASSAROTTO.pdf: 924874 bytes, checksum: 09a1ac55208a09df27e003db121d89d6 (MD5) / Made available in DSpace on 2018-02-07T13:06:22Z (GMT). No. of bitstreams: 1 ANA CAROLINA MASSAROTTO.pdf: 924874 bytes, checksum: 09a1ac55208a09df27e003db121d89d6 (MD5) Previous issue date: 2017-12-15 / Breast cancer is the second most common type of cancer in the world, and the most common among women, affecting men who account for 1% of all cases of the disease. The risk factors of the disease are related to age, endocrine / reproductive history, behavioral / environmental factors, and genetic / hereditary factors. The prognosis of the disease depends on its extension (staging), with greater curative potential when diagnosed at baseline.Among the types of treatment of breast cancer stand out surgery, radiotherapy, chemotherapy, hormone therapy and biological therapy. It is highlighted in the radiotherapy modality, Brachytherapy, which is the application of radiation in a more precise and localized way in the tumor. In this work we will focus on high-grade interstitial brachytherapy dose rate, partial and accelerated breast irradiation (IPAM), which has been shown to have better esthetic results, lower risk of injury from radiation from healthy adjacent tissues, shorter duration of treatment, and low recurrence rates. This is a retrospective, longitudinal, descriptive, analytical study, with a review of medical records of patients diagnosed with breast cancer, stages 0-I-II, between the years 2004 and 2013 who received IPAM using brachytherapy after conservative surgery of the breast at the Radium Institute of Campinas, Campinas-SP, Brazil.This work aims to report and evaluate the viability, acute and chronic toxicity, aesthetic aspects, efficacy and factors related to the use of Partial and Accelerated Breast Irradiation with high dose rate brachytherapy for patients with early stage of breast cancer. In addition to assessing recurrence rates and local control of the disease. / O c?ncer de mama ? o segundo tipo de c?ncer mais comum no mundo,e o mais frequente entre as mulheres, acometendo tamb?m homens que representam 1% do total de casos da doen?a. Os fatores de risco da doen?a est?o relacionados com idade, fatores end?crinos/hist?ria reprodutiva, fatores comportamentais/ambientais e fatores gen?ticos/heredit?rios. O progn?stico da doen?a depende da sua extens?o (estadiamento), com maior potencial curativo quando diagnosticada no in?cio. Entre os tipos de tratamento do c?ncer de mama destacam-se a cirurgia, radioterapia , quimioterapia, hormonioterapia e terapia biol?gica. Apresenta destaque na modalidade radioter?pica, a Braquiterapia, que trata-se da aplica??o de radia??o de forma mais precisa e localizada no tumor. Neste trabalho teremos como enfoque a braquiterapia intersticial de alta taxa de dose, irradia??o parcial e acelerada da mama (IPAM), que vem apresentando melhores resultados est?ticos, menor risco de les?o pela radia??o de tecidos adjacentes saud?veis, menor dura??o do tratamento, e baixas taxas de recorr?ncia. Trata-se de um estudo retrospectivo, longitudinal, descritivo, anal?tico, com revis?o de prontu?rios de pacientes com diagn?stico de c?ncer de mama, est?dios 0-I-II , entre os anos de 2004 e 2013 que receberam IPAM utilizando braquiterapia ap?s a cirurgia conservadora da mama no Instituto do Radium de Campinas, Campinas-SP, Brasil. Tal trabalho objetiva relatar e avaliar a viabilidade, toxicidade aguda e cr?nica, aspectos est?ticos, efic?cia e fatores relacionados com utiliza??o de Irradia??o Parcial e Acelerada da Mama com braquiterapia de alta taxa de dose para pacientes com est?dio inicial de c?ncer de mama. Al?m de avaliar as taxas de recorr?ncia e controle local da doen?a.
40

Associa??o da Radioterapia externa (RTe) com braquiterapia de alta taxa de dose (BTATD), no tratamento do c?ncer de pr?stata (CaP). / Association of External Radiotherapy (RTe) with high dose rate brachytherapy (BTATD) in the treatment of prostate cancer (CaP).

Jos? Junior, Vanderlei 15 December 2017 (has links)
Submitted by SBI Biblioteca Digital (sbi.bibliotecadigital@puc-campinas.edu.br) on 2018-02-15T12:50:05Z No. of bitstreams: 1 VANDERLEI JOSE JUNIOR.pdf: 1351825 bytes, checksum: 599d050ec951a6a8e7497a0cea5d2e17 (MD5) / Made available in DSpace on 2018-02-15T12:50:05Z (GMT). No. of bitstreams: 1 VANDERLEI JOSE JUNIOR.pdf: 1351825 bytes, checksum: 599d050ec951a6a8e7497a0cea5d2e17 (MD5) Previous issue date: 2017-12-15 / Introduction: Prostate cancer is one of the most prevalent diseases in the male population, occupying the second position among malignant neoplasms. There are several therapeutic options for the treatment of localized prostate cancer, ranging from conservative behaviors to interventional treatments such as radical prostatectomy or external radiotherapy, associated or not with brachytherapy. Objective: To identify the factors that can predict biochemical recurrence and to evaluate treatment toxicity. METHOD: This is a retrospective and longitudinal study of 162 patients diagnosed with prostate cancer treated with conformational external radiotherapy associated with high dose rate brachytherapy (BTATD) between 2005 and 2014. The database was used of the Radium ? Campinas Oncology Institute, collected prospectively. Results: The mean follow-up time was 57 months. No grade 3 late toxicity was observed in the gastrointestinal tract, with only 1 patient (0.6%) genitourinary tract. The only categorical variable that presented statistical significance for biochemical relapse was the Nadir PSA <1 ng / ml (p = 0.018). The biochemical recurrence rate found was 96.3%, based on the Phoenix criteria (PSA nadir + 2 ng / ml). Conclusions: This study demonstrated that in the treatment of localized prostate cancer, the association of external radiotherapy with BATD is a safe therapeutic option, with a low degree 3 late toxicity and a biochemical recurrence of only 3.7% (with HF = 95 %). / Introdu??o: O c?ncer de pr?stata ? uma das doen?as mais prevalentes na popula??o masculina, ocupando a segunda posi??o entre as neoplasias malignas. H? v?rias op??es terap?uticas para o tratamento do c?ncer de pr?stata localizado, podendo variar de condutas conservadoras ? tratamentos intervencionistas como a prostatectomia radical ou a radioterapia externa, associada ou n?o ? braquiterapia. Objetivo: Identificar os fatores que possam predizer recidiva bioqu?mica e avaliar a toxicidade do tratamento. M?todo: Tratase de um estudo retrospectivo e longitudinal, com 162 pacientes diagnosticados com c?ncer de pr?stata, tratados com radioterapia externa conformacional associada ? braquiterapia de alta taxa de dose (BATD), entre 2005 e 2014. Utilizou-se o banco de dados do Radium - Instituto de Oncologia de Campinas, coletados prospectivamente. Resultados: O tempo m?dio de seguimento foi de 57 meses. N?o foi observada toxicidade tardia grau 3 no trato gastrointestinal, sendo apenas 1 paciente (0,6%) trato genitourin?rio. A ?nica vari?vel categ?rica que apresentou signific?ncia estat?stica para recidiva bioqu?mica foi o PSA Nadir <1 ng/ ml (p = 0,018). A taxa de recidiva bioqu?mica encontrada foi de 96,3%, baseando-se nos crit?rios de Phoenix (PSA nadir + 2 ng/ml). Conclus?es: Esse estudo demonstrou que, no tratamento de c?ncer de pr?stata localizado, a associa??o de radioterapia externa com BATD ? uma op??o terap?utica segura, com baixa taxa de toxicidade tardia grau 3 e recidiva bioqu?mica de apenas 3,7% (com I.C = 95%).

Page generated in 0.0685 seconds