• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Industriventilation i textilproduktion : Energieffektivisering och påverkan på inneklimat / Industrial ventilation in textile production : Energy efficiency and impact on indoor climate

Persson, Joakim January 2018 (has links)
Klässbols Linneväveri AB är ett av Sveriges få linneväverier och bedriver sin verksamhet med produktion och försäljning av linneprodukter som bland annat dukar, handdukar och gardiner på plats i Klässbol, Värmland. I arbetet med att minska företagets energianvändning undersöks om produktionslokalernas ventilationssystem, som kräver stora mängder energi, kan effektiviseras utan negativ inverkan på produktionen.    Energiförbrukning är kopplat till storlek och uppvärmning av luftflöden. Syftet med denna rapport är att undersöka möjligheterna till förbättring av ventilationssystemets funktion till förmån för produktionsprocessen, energieffektivisering av systemets drift samt tillgodose krav för arbetsmiljö.    Industriventilation i textilproduktion ställer höga krav på luftens relativa fuktighet beroende på dess betydelse för råvaran, i detta fall linets hållbarhet. Förutom att hantera luftens relativa fuktighet måste ventilationssystemet också hantera det luftburna textildamm som alstras vid maskiner och vävstolar.   Efter en kartläggning av verksamheten, ventilationssystemet och rådande inneklimat har balansberäkningar genomförts för att ta fram alternativa luftflöden utifrån de krav som ställs från produktionsprocessen och personal som arbetar i lokalerna. Kartläggningen konstaterar att problematiken under vintertid består i att nå önskad nivå av relativ luftfuktighet (RH) som begränsas av köldbryggor i taket. I nuläget är RH 50 % vilket anses vara för lågt. Vidare visar kartläggningen att dammpartikelkoncentrationen i produktionslokalerna inte överskrider angivna gränsvärden.   Resultat av beräkningarna visar att nuvarande RH i produktionslokalerna kan åstadkommas med minskade luftflöden. Detta innebär även minskad energiförbrukning och minskad driftskostnad med 22,6 tkr/år. För att öka RH i produktionslokalerna till önskvärda 75 % eller uppnå det högsta RH som ventilationssystemet har kapacitet för krävs ökade luftflöden för större delen av året. Förbättrat inneklimat för produktionsprocessen medför därmed ökad energiförbrukning och ökad driftskostnad med 46,9 tkr/år respektive 57,5 tkr/år. / Klässbols Linneväveri AB is one of Sweden's few linen weaving mills located in Klässbol, Värmland. The company engages in production and sales of linen products, such as tablecloths, towels and curtains. As part of the work to reduce the company's energy use research on the production premises ventilation system, that require large amounts of energy, can be streamlined without adverse impact on production.   Energy consumption is associated with the size and the heating of airflows. The purpose of this report is to investigate the possibilities for improving the ventilation system's function in favour of the production process, energy efficiency of system operation as well as meeting occupational health and safety requirements.   Industrial ventilation in textile production places high demands on the relative humidity of the air due to its importance to the raw material, in this case the durability of linen. In addition to handling the relative humidity of the air, the ventilation system must also handle the airborne textile dust generated by machines and looms.   After a survey of the operations, the ventilation system and the present indoor climate, balance calculations have been conducted to develop alternative airflows based on the requirements of the production process and the working staff.The survey finds that the problem during winter is to achieve the desired level of relative humidity (RH) which is limited due to lack of isolation in the ceiling. At present RH is 50%, which is considered to be too low. Furthermore, the mapping shows that the dust concentration in the production sites does not exceed specified limit values.   The results of the calculations show that current RH in the production sites can be achieved with reduced airflows. This also means reduced energy consumption and reduced operating costs by SEK 22,6 thousand per year. To increase RH in the production sites to desirable 75% or to achieve the highest RH that the ventilation system can deliver, airflows need to be increased for most of the year. Improved indoor climate for the production process involves thus increased energy consumption and increased operating costs by SEK 46,9 thousand per yearrespectively SEK 57,5 thousand per year.
2

Styrning av inneklimat i kyrkor : Enkla åtgärder för att undvika hög luftfuktighet och mögel

Trogen, Claes, Östlund, Patrik January 2021 (has links)
Churches are old historical buildings often built of stone that carry a heritagethat is important to preserve for the future. It’s common that churches haveproblems with high relative humidity which also causes mold growth. Moldspores are found naturally in the air but require good conditions, such as highhumidity, materials to adhere to and a favorable temperature, to start growing.Attempts have been made to reduce the humidity in churches with varioushumidity-limiting methods. The purpose of this study is to investigate whetherclimate control methods can prevent the growth of church mold and control therelative humidity so that the results can provide guidelines for other churcheswith the same problems. Nine churches in north Gotland's pastorate have been used in the study. In threeof these, textile cabinets were installed in the sacristy for three different climatecontrol methods: humidity-controlled dehumidification, mechanical exhaustventilation and humidity-controlled heating element. These were measured overan eight-month period with a data logger that measured the relative humidityand temperature once every half an hour. Measurements were also taken fromthe respective sacristy. For the other six churches, measurements were taken bythe organ during a 12-month period with the same data logger. Then a moisturecontrolled dehumidifier was installed in only three of the churches in the middleof the church room. The relative humidity and temperature were measured onceagain in all six churches for the next eight months. The results from this study show that in the three churches where moisturecontrolled dehumidification was installed, the measured values were slightlybetter for both relative humidity and the risk of developing mold. In the textilecabinets, on the other hand, the values for both relative humidity and the riskof mold were slightly higher than in those for the respective sacristy. However,the values were somewhat more stable which is a good thing. The need to regulate the climate of churches will not decrease. Finding costeffective solutions for controlling the indoor climate is therefore important forpreserving their cultural-historical heritage.
3

FUKTSKADOR I UTELUFTSVENTILERAD KRYPGRUND : Med avseende på klimatförändringar och installation av golvvärme

Louise, Breman, Andreas, Svensson January 2016 (has links)
Syfte: Idag riskerar cirka 300 000 hushåll med uteluftsventilerad krypgrund att bli angripna av fukt- och mögelskador. Klimatet i en uteluftsventilerad krypgrund påverkas i stor grad av temperaturen och den relativa luftfuktigheten. Det råder inga tvivel om att klimatet står inför förändringar, vilket innebär en höjd temperatur och en förändring av den relativa luftfuktigheten. Detta gör att den uteluftsventilerade krypgrunden inte har möjlighet att torka ut under vissa perioder på året och utsätts då för en förhöjd risk av fuktskador. Parallellt med klimatförändringen moderniseras även uppvärmningssystemen i småhusen, vilket ändrar förutsättningar för krypgrunderna. Målet med arbetet är att undersöka om klimatförändringarna och installation av golvvärme i träbjälklaget har bidragit till fuktskador i uteluftsventilerade krypgrunder och ge underlag till effektivare åtgärder av fuktskador. Metod: För att utreda om klimatförändringarna är ett problem för de uteluftsventilerade krypgrunderna har dokumentanalyser genomförts vilka sedan följdes av beräkningar av krypgrundens relativa luftfuktighet. På samma sätt gavs svar på om golvvärmen är en bidragande faktor till fuktskadorna. Båda frågeställningarna styrktes även av kvalitativa intervjuer med sakkunniga personer. Hur fuktskadorna effektivare kunde åtgärdas togs främst fram genom kvalitativa intervjuer men styrktes av dokumentanalyser. Resultat: Studien visar att klimatförändringarna kommer att påverka uteluftsventilerade krypgrunder i positiv bemärkelse då studien endast tog hänsyn till temperaturhöjningen. Installation av golvvärme har även visats vara positivt mot fuktskador i en uteluftsventilerad krypgrund om isolering i bjälklaget saknas eller är bristfällig. Branschen ser ingen vinst i att effektivisera åtgärdsmetoderna då dessa redan är välprövade och väl fungerande. Konsekvenser: Ett varmare klimat ger bättre förutsättningar för en uteluftsventilerad krypgrund. Medvetenheten om hur klimatförändringarna påverkar krypgrunderna ger byggbranschen ett försprång att förbereda sig inför kommande förändringar. Kunskapen om att golvvärme kan ge positiva effekter mot fuktskador i uteluftsventilerade krypgrunder ger nya förutsättningar för renoveringar och åtgärder mot fuktskador, dock måste energiförlusterna tas i hänsyn i dessa fall. Branschen ser ingen vinst i att effektivisera åtgärdsmetoderna, vilket gör att det inte finns någon anledning att gå djupare in i detta. Begränsningar: Arbetet behandlar endast uteluftsventilerade krypgrunder med träbjälklag som ligger inom Sveriges gränser. Denna studie är därför inte applicerbar på andra konstruktioner eller utanför Sveriges gränser. Endast klimatförändringarna det senaste seklet och fram till 2100 tas hänsyn till i rapporten. Studien tar heller inte hänsyn till fukttillskott från mark och dagvatten, likaså görs inga beräkningar på ventilation. / Purpose: Today are about 300 000 buildings with outdoor ventilated crawl space at risk to be contaminated by moisture and mold damage. An outdoor ventilated crawl space’s climate is greatly affected by the temperature and the relative humidity. There is no doubt that the climate is facing changes, which means an increased temperature and a change in the relative humidity. This prevents the outdoor ventilated crawl space from drying out during certain periods of the year and is then exposed to a heightened risk of moisture damage. Parallel to the climate change the heating systems are being modernized in houses, which changes the conditions for the crawl spaces. The objective of this essay is to do a research if climate change and the installation of underfloor heating in the greater part of the joist area has given rise to moisture damage in outdoor ventilated crawl spaces and provide good basis for more effective measures to moisture damage. Method: To investigate whether the climate change is a problem for outdoor ventilated crawl spaces have document analyzes been conducted, which was followed by calculations of the crawl spaces’ relative humidity. Calculations have been made to find out if the underfloor heating is a contributing problem to moisture damage. Both issues are also corroborated by interviews with qualified people. How the moisture damage more effective could be fixed was answered primarily through qualitative interviews, but corroborated by document analysis. Findings: The study shows that climate change will affect outdoor ventilated crawl spaces in a positive sense, only account to the temperature rise. Installing underfloor heating has also been shown to be positive against moisture damage in outdoor ventilated crawl spaces if insulation in the soffit is missing or deficient. The industry sees no gain in efficiency action methods as these are already proven and well- functioning. Implications: A warmer climate provides better conditions for outdoor ventilated crawl space. Being aware of the changes associated with climate change, and its effects on buildings give the construction industry a head start to prepare for future changes. Knowledge that underfloor heating can provide positive effects against moisture damage in crawl spaces creates new opportunities for renovations and actions against dampness but the energy losses in this case must be considered. Since the industry does not see profit in streamlining action methods is no need to go deeper into this. Limitations: The report deals only outdoor ventilated crawl spaces with wooden soffit that is located within the Swedish borders. This study is therefore not applicable to other constructions or other countries. Only climate change in the last century and up until 2100 are taken into account in the report. Further on the study does not take the excess moisture from the soil or the storm water into account; likewise there are no calculations for the ventilation.
4

En undersökning av möjliga tillväxtmiljöer vid den tidiga sågverkshanteringen av ek / An investigation of posible growth environments for mould in the early sawmill handling of oak

Herdinius, Andreas January 2019 (has links)
Trä är ett biologiskt och organiskt material vars egenskaper möjliggör att det vid rätt förhållanden kan växa mögel på det. Mögeltillväxt på trä som människor hanterar och har i sin närhet kan skapa hälsoproblem då vissa mögelarter kan orsaka respiratoriska problem samt allergisk alveolit.En undersökning av vilken mögelsvamp som växer på brädor vid ett sågverk i södra Sverige har utförts. Utöver detta har möjliga tillväxtmiljöer för mögel undersökts under brädgårdstorkning samt en torkprocess. De undersökta parametrarna var temperatur och relativ luftfuktighet.Mögelsvampen Paecilomyces hittades samt Aspergillus niger och jäst. Klimatet under brädgårdstorkning samt torkprocessen visade att de under stor del av den tidiga hanteringen av virket fanns ett klimat gynnsamt för mögeltillväxt. / Wood is a biological and organic material whose properties makes it possible for mold to grow on it under the right conditions. Mold growth on wood that humans handle and get in contact with can create health problems as some mold species can cause respiratory problems and allergic alveolitis.An investigation of which mold that grows on boards at a sawmill in southern Sweden has ben carried out. In addition to this, possible growth environments for mold have been investigated during lumber yard drying and a kiln drying process. The parameters examined were temperature and relative humidity.Mold of Paecilomyces, Aspergillus niger and yeast was found on boards. The climate during lumber yard drying and the kiln drying process showed that a large part of the early handling of the wood had a favourable climate to mold growth.
5

Fältmätningar av termisk komfort och luftkvalitet i kontorsrum i äldre temperaturreglerad stenbyggnad

Boström, Hanna, Lindelöw, Hanna January 2022 (has links)
Personal på Högskolan i Gävle tycks periodvis uppleva dålig komfort ikontorsrummen på södersidan i skolans gamla kasernbyggnader. En undersökninggjordes därför på högskolan i april månad i tre kontor, ett med fönsterhuvudsakligen i norrläge och två med fönster huvudsakligen i söderläge. Syftet varatt kartlägga den termiska komforten och luftkvaliteten i de olika väderstrecken ochjämföra med gällande rekommendationer, bland annat genom att beräkna PMV vidolika tillfällen. Vidare undersöktes potentiella samband mellan ute- och inneklimatsamt tunna gardiners inverkan på termostat, värmeflöde och komfort. Den undersökta byggnaden är en äldre stenbyggnad med ovanligt välisoleradefönster och termostatstyrda, vätskeburna radiatorer. Byggnaden har FTX-ventilationmed ett till- och ett överluftsdon i varje kontorsrum. Mätningarna utfördes meddataloggrar som mätte lufttemperatur, relativ luftfuktighet och koldioxidhalt. I tvåav rummen mättes även globtemperatur. Utöver det mättes lufthastighet på tre olikahöjder i två av rummen samt ventilationsflödet i samtliga rum. Resultatet visade att inomhus- och utomhustemperatur har en relativt högkorrelation. Relativa luftfuktigheten var nästan alltid högst i norrläge, men i samtligarum var den låg – lägre än vad som rekommenderas i riktlinjerna. Soligt väderpåverkade temperatur och relativ luftfuktighet inomhus mest av alla vädervariabler,men personnärvaro och ventilation påverkade mer än utomhusklimatet. Kontor isöderläge hade som förväntat högre temperatur än i norrläge, och översteg deriktlinjer som finns för temperatur i kontor. Som följd av detta blev PMV högre isöderläge, tillfälligt högre än komfortgränsen 0,5, med ett högsta värde på 1,41. Kontoret i norrläge höll sig vid de undersökta tillfällena inom intervallet föraccepterat PMV med ett lägsta värde på -0,35. Detta tyder på att värme i söderlägeär ett större problem än kyla i norrläge. Lufthastigheterna blev låga i bådaväderstrecken. Ventilationsflödena visade sig vara 2/3 av det projekterade värdet,men ändå låg koldioxidhalten på en acceptabel nivå enligt riktlinjer. Gardiner påverkade komforten mer i söderläge än norrläge, men påverkade intetillräckligt mycket för att komma ner i en acceptabel komfortnivå vilket kan bero påatt de var av mycket tunt material. Det var svårt att se tydlig gardinpåverkan påtermostaten, men fråndragna gardiner kan leda till att termostaten reagerar påtemperaturökningar i ett rum snabbare. Däremot påverkades värmeflödet tydligaregenom fönstret av gardinerna. Skillnaden i värmeflödet vid för- och fråndragnagardiner blev 4,1 W. / Employees at University of Gävle seem to periodically experience suboptimalcomfort in south facing offices in the school’s old barrack buildings. Therefore, acase study was conducted in April in three offices, one facing north and two facingsouth. The aim of the study was to map the thermal comfort and air quality in thedifferent directions and compare these to the existing recommendations, includingcalculating PMV at different times. A potential correlation between out- and indoorclimate was also examined, as well as the effect of thin curtains on the thermostat, heat flux and comfort. The University of Gävle is an old brick building with unusually well insulatingwindows and thermostatically regulated, waterborne radiators. The building hasmechanical ventilation with heat recovery, and each office has one supply and oneover-air diffuser. The measurements were made with data loggers that measured airtemperature, relative humidity and carbon dioxide. The globe temperature was alsomeasured in two of the rooms. The air velocity on three heights was measured aswell in two of the offices and the ventilation flow was measured in all the rooms. The result showed that indoor- and outdoor temperature have a relatively highcorrelation. The relative humidity was almost always higher in the north facingoffice, but in all the rooms it was low – lower than the recommended guidelines.Sunny weather affected the indoor temperature and relative humidity the most of allthe weather variables, but presence of people and ventilation affected more than theoutdoor climate. South facing offices had as expected a higher temperature thannorth facing ones, and exceeded the guidelines concerning temperatures in offices.Due to that the PMV was higher in the south facing office, temporarily exceedingthe comfort limit of 0,5, with a maximum value of 1,41. The north facing office waswithin the limits during the measurements and had a minimum value of -0,35. Thisindicates that heat in the south facing office is more of a problem than coldness inthe north facing office. The air velocities were low in both directions of thebuilding. The ventilation flow turned out to be 2/3 of the intended value, but thecarbon dioxide content was still acceptable according to guidelines. Curtains influenced the comfort more in the south facing office than in the northfacing office, but they didn’t influence enough to get to an acceptable comfort level,which may be because of the very thin material. It was difficult to see a distinctinfluence from the curtains on the thermostat, but using no curtains could lead tothe thermostat responding faster to increases in temperature in a room. However,the heat flow through the window was influenced more distinctly by the curtains.The difference in heat flow when using curtains compared to no curtains was 4,1 W.
6

Klimatförhållanden och energianvändning på Gränby ishall : Hur Uppsala kommun Arenor och fastigheter AB kan förbättra klimatförhållandena och sänka energianvändningen i Gränby ishall

Kylhed, Ebba January 2024 (has links)
This report intends to investigate climate conditions and energy consumption in Gränby Ice rink in Uppsala.Today, Gränbyhallen faces a potential renovation project to modernize and improve what was initially intended as a temporary hall that was inaugurated in 1974.In 2021, the property was taken over by the Uppsala municipality Arenor och Fastigheter AB from having previously been owned by the municipality. Since then, Arenor och Fastigheter has worked to modernize its facilities and in this way also work to improve the energy consumption required by the operation of the Gränby ice rink and also examine the indoor climate conditions in the building.The idea is to make the climate more pleasant for the visitors, and therefore making it less cold and barren temperaturevise by separating the ventilation from the ice and bleachers so that these can be controlled individually. The hope is to be able to reduce energy consumption with such a solution by seeing if the facility has heat leakage from the outside and how moisture can be managed in the facility to be kept at a more even level throughout the year and during the day.For the report, weather data was obtained from SMHI and then compiled and compared with temperatures and energy consumption from sorption dehumidifiers and the plant total to locate current deficiencies but also how to potentially address these to lower energy consumption.Analysis of the data was also done for the outdoor temperature which was set against the indoor temperature and then also the difference between the two to see the difference anddemonstrate how well insulated the facility is. On average over the entire time investigated, there was only +1°C difference between outside and inside, which gives an indication that the insulation in the facility needs to be reviewed and improved both outside and inside as there are large leaks in the facility with open surfaces and only metal doors that separate warm surfaces from cold.The analysis also suggests that the dehumidifier should be changed to regulate according to the dew point temperature from regulating according to the relative humidity as the dew point changes less over time and is less affected by the amount of water in the air which changes from hour to hour and is also affected by the outdoor climate when doors are opened and closed to the facility. / Denna rapport avser att undersöka klimatförhållanden och energiförbrukningen i Gränby ishall i Uppsala. Idag står Gränbyhallen inför ett potentiellt renoveringsarbete för att modernisera och förbättra till en som till en början var tänkt som en provisorisk hall från 1974. 2021 togs fastigheten över av Uppsala kommun Arenor och Fastigheter AB från att tidigare varit kommunägt. Arenor och Fastigheter har sedan dess arbetat med att modernisera sina fastigheter och på så sätt även arbeta med att förbättra energiförbrukningen som driften i Gränby ishall kräver och även undersöka klimatförhållandena inomhus. Tanken är att göra klimatet för åskådarna mer behagligt att vistas i från dagens kalla och karga temperaturer genom att separera läktarens ventilation och avfuktning från isens, så att dessa kan styras enskilt och därmed ha olika klimat. Förhoppningen är att med en sådan lösning kunna minska energiförbrukningen genom att se ifall anläggningen har värmeläckage från utsidan samt hur fukt kan hanteras i anläggningen för att hållas på en mer jämn nivå över året och under dagen. Till rapporten har väderdata hämtats från SMHI och sedan sammanställts och jämförts med temperaturer och energiförbrukning från sorptionsavfuktare och anläggningens total för att lokalisera nuvarande brister, men även hur man kan potentiellt åtgärda dessa för att sänka energiförbrukningen. Analys av data gjordes även för temperaturen utomhus mot temperaturen inomhus och då differensen av de två för att se skillnaden och påvisa även hur väl isolerad anläggningen är. I genomsnitt över hela tiden som undersöktes skildes det bara +1°C mellan ute och inne, vilket ger indikation på att isoleringen i anläggningen behöver ses över och förbättras både ute och inne då det finns stora läckage i anläggningen med öppna ytor och endast plåtdörrar som separerar varma ytor från kalla. Analysen tyder även på att avfuktaren bör ändras till att reglera efter daggpunktstemperaturen i stället för som nu efter relativa luftfuktigheten. Daggpunkten ändras mindre över tid och påverkas mindre av luftens vattenmängd, som ändras från timme till timme och som påverkas även av utomhusklimatet när dörrar öppnas och stängs till anläggningen.

Page generated in 0.0774 seconds