• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 4
  • 3
  • 1
  • Tagged with
  • 17
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dyka efter spänning : Sensation seeking scale testad på dykare

Nohrenius, Peter, Åsander, Madeleine January 2012 (has links)
Är dykare spänningssökare? Är män mer spänningssökande än kvinnor? 51 dykare, 27 män och 24 kvinnor, läts fylla i enkäten Sensation seeking scale version 5 (SSS-V). Sensation seeking scale har utvecklats av Marvin Zuckerman med kollegor sedan 1960-talet och mäter graden av spänningssökande personlighetsdrag, på engelska: sensation seeking. Enkäten har visat sig valid på flera hundra studier men har bara testats på dykare ett fåtal gånger. Hypoteserna är att dykare är mer spänningssökande än normalpopulationen (H1) och att dykande män är mer spänningssökande än dykande kvinnor (H2). Kontrollgruppen består av psykologistudenter från Delware University mellan år 1986 och 1992, 410 män och 807 kvinnor. Resultatet visar med statistisk signifikant säkerhet att dykare är mer spänningssökande än normalpopulationen och att dykande män är mer spänningssökande än dykande kvinnor. Validitet och alternativ till Sensation seeking scale m.m. tas upp i diskussionsdelen.
2

Development of methods for time efficient scatter correction and improved attenuation correction in time-of-flight PET/MR

Nikulin, Pavel 06 November 2019 (has links)
In der vorliegenden Dissertation wurden zwei fortdauernde Probleme der Bildrekonstruktion in der time-of-flight (TOF) PET bearbeitet: Beschleunigung der TOF-Streukorrektur sowie Verbesserung der emissionsbasierten Schwächungskorrektur. Aufgrund der fehlenden Möglichkeit, die Photonenabschwächung direkt zu messen, ist eine Verbesserung der Schwächungskorrektur durch eine gemeinsame Rekonstruktion der Aktivitäts- und Schwächungskoeffizienten-Verteilung mittels der MLAA-Methode von besonderer Bedeutung für die PET/MRT, während eine Beschleunigung der TOF-Streukorrektur gleichermaßen auch für TOF-fähige PET/CT-Systeme relevant ist. Für das Erreichen dieser Ziele wurde in einem ersten Schritt die hochauflösende PET-Bildrekonstruktion THOR, die bereits zuvor in unserer Gruppe entwickelt wurde, angepasst, um die TOF-Information nutzen zu können, welche von allen modernen PET-Systemen zur Verfügung gestellt wird. Die Nutzung der TOF-Information in der Bildrekonstruktion führt zu reduziertem Bildrauschen und zu einer verbesserten Konvergenzgeschwindigkeit. Basierend auf diesen Anpassungen werden in der vorliegenden Arbeit neue Entwicklungen für eine Verbesserung der TOF-Streukorrektur und der MLAA-Rekonstruktion beschrieben. Es werden sodann Ergebnisse vorgestellt, welche mit den neuen Algorithmen am Philips Ingenuity PET/MRT-Gerät erzielt wurden, das gemeinsam vom Helmholtz-Zentrum Dresden-Rossendorf (HZDR) und dem Universitätsklinikum betrieben wird. Eine wesentliche Voraussetzung für eine quantitative TOF-Bildrekonstruktionen ist eine Streukorrektur, welche die TOF-Information mit einbezieht. Die derzeit übliche Referenzmethode hierfür ist eine TOF-Erweiterung des single scatter simulation Ansatzes (TOF-SSS). Diese Methode wurde im Rahmen der TOF-Erweiterung von THOR implementiert. Der größte Nachteil der TOF-SSS ist eine 3–7-fach erhöhte Rechenzeit für die Berechnung der Streuschätzung im Vergleich zur non-TOF-SSS, wodurch die Bildrekonstruktionsdauer deutlich erhöht wird. Um dieses Problem zu beheben, wurde eine neue, schnellere TOF-Streukorrektur (ISA) entwickelt und implementiert. Es konnte gezeigt werden, dass dieser neue Algorithmus eine brauchbare Alternative zur TOF-SSS darstellt, welche die Rechenzeit auf ein Fünftel reduziert, wobei mithilfe von ISA und TOF-SSS rekonstruierte Schnittbilder quantitativ ausgezeichnet übereinstimmen. Die Gesamtrekonstruktionszeit konnte mithilfe ISA bei Ganzkörperuntersuchungen insgesamt um den Faktor Zwei reduziert werden. Dies kann als maßgeblicher Fortschritt betrachtet werden, speziell im Hinblick auf die Nutzung fortgeschrittener Bildrekonstruktionsverfahren im klinischen Umfeld. Das zweite große Thema dieser Arbeit ist ein Beitrag zur verbesserten Schwächungskorrektur in der PET/MRT mittels MLAA-Rekonstruktion. Hierfür ist zunächst eine genaue Kenntnis der tatsächlichen Zeitauflösung in der betrachten PET-Aufnahme zwingend notwendig. Da die vom Hersteller zur Verfügung gestellten Zahlen nicht immer verlässlich sind und zudem die Zählratenabhängigkeit nicht berücksichtigen, wurde ein neuer Algorithmus entwickelt und implementiert, um die Zeitauflösung in Abhängigkeit von der Zählrate zu bestimmen. Dieser Algorithmus (MLRES) basiert auf dem maximum likelihood Prinzip und erlaubt es, die funktionale Abhängigkeit der Zeitauflösung des Philips Ingenuity PET/MRT von der Zählrate zu bestimmen. In der vorliegenden Arbeit konnte insbesondere gezeigt werden, dass sich die Zeitauflösung des Ingenuity PET/MRT im klinisch relevanten Zählratenbereich um mehr als 250 ps gegenüber der vom Hersteller genannten Auflösung von 550 ps verschlechtern kann, welche tatsächlich nur bei extrem niedrigen Zählraten erreicht wird. Basierend auf den oben beschrieben Entwicklungen konnte MLAA in THOR integriert werden. Die MLAA-Implementierung erlaubt die Generierung realistischer patientenspezifischer Schwächungsbilder. Es konnte insbesondere gezeigt werden, dass auch Knochen und Hohlräume korrekt identifiziert werden, was mittels MRT-basierter Schwächungskorrektur sehr schwierig oder sogar unmöglich ist. Zudem konnten wir bestätigen, dass es mit MLAA möglich ist, metallbedingte Artefakte zu reduzieren, die ansonsten in den MRT-basierten Schwächungsbildern immer zu finden sind. Eine detaillierte Analyse der Ergebnisse zeigte allerdings verbleibende Probleme bezüglich der globalen Skalierung und des lokalen Übersprechens zwischen Aktivitäts- und Schwächungsschätzung auf. Daher werden zusätzliche Entwicklungen erforderlich sein, um auch diese Defizite zu beheben. / The present work addresses two persistent issues of image reconstruction for time-of-flight (TOF) PET: acceleration of TOF scatter correction and improvement of emission-based attenuation correction. Due to the missing capability to measure photon attenuation directly, improving attenuation correction by joint reconstruction of the activity and attenuation coefficient distribution using the MLAA technique is of special relevance for PET/MR while accelerating TOF scatter correction is of equal importance for TOF-capable PET/CT systems as well. To achieve the stated goals, in a first step the high-resolution PET image reconstruction THOR, previously developed in our group, was adapted to take advantage of the TOF information delivered by state-of-the-art PET systems. TOF-aware image reconstruction reduces image noise and improves convergence rate both of which is highly desirable. Based on these adaptations, this thesis describes new developments for improvement of TOF scatter correction and MLAA reconstruction and reports results obtained with the new algorithms on the Philips Ingenuity PET/MR jointly operated by the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) and the University Hospital. A crucial requirement for quantitative TOF image reconstruction is TOF-aware scatter correction. The currently accepted reference method — the TOF extension of the single scatter simulation approach (TOF-SSS) — was implemented as part of the TOF-related modifications of THOR. The major drawback of TOF-SSS is a 3–7 fold increase in computation time required for the scatter estimation, compared to regular SSS, which in turn does lead to a considerable image reconstruction slowdown. This problem was addressed by development and implementation of a novel accelerated TOF scatter correction algorithm called ISA. This new algorithm proved to be a viable alternative to TOF-SSS and speeds up scatter correction by a factor of up to five in comparison to TOF-SSS. Images reconstructed using ISA are in excellent quantitative agreement with those obtained when using TOF-SSS while overall reconstruction time is reduced by a factor of two in whole-body investigations. This can be considered a major achievement especially with regard to the use of advanced image reconstruction in a clinical context. The second major topic of this thesis is contribution to improved attenuation correction in PET/MR by utilization of MLAA reconstruction. First of all, knowledge of the actual time resolution operational in the considered PET scan is mandatory for a viable MLAA implementation. Since vendor-provided figures regarding the time resolution are not necessarily reliable and do not cover count-rate dependent effects at all, a new algorithm was developed and implemented to determine the time resolution as a function of count rate. This algorithm (MLRES) is based on the maximum likelihood principle and allows to determine the functional dependency of the time resolution of the Philips Ingenuity PET/MR on the given count rate and to integrate this information into THOR. Notably, the present work proves that the time resolution of the Ingenuity PET/MR can degrade by more than 250 ps for the clinically relevant range of count rates in comparison to the vendor-provided figure of 550 ps which is only realized in the limit of extremely low count rates. Based on the previously described developments, MLAA could be integrated into THOR. The performed list-mode MLAA implementation is capable of deriving realistic, patient-specific attenuation maps. Especially, correct identification of osseous structures and air cavities could be demonstrated which is very difficult or even impossible with MR-based approaches to attenuation correction. Moreover, we have confirmed that MLAA is capable of reducing metal-induced artifacts which are otherwise present in MR-based attenuation maps. However, the detailed analysis of the obtained MLAA results revealed remaining problems regarding stability of global scaling as well as local cross-talk between activity and attenuation estimates. Therefore, further work beyond the scope of the present work will be necessary to address these remaining issues.
3

Automatic safety and speed enforcement systems. An economic study

Rundqvist, Elena January 2010 (has links)
There is a debate in Sweden if the Automatic Safety and speed enforcement systems (SSS) in Sweden are profitable or not. Cost benefit analysis (CBA) is an excellent tool for determining the economy of traffic safety measures. The parameters of the CBA in this work include: tire wear, fuel consumption, environmental pollution, saved lives and injuries, reduced material damage, time for disputing tickets, time in traffic lines due to accidents, longer time due to lower speed and collected fines and maintained cost for the SSS. The sensitivity analysis shows that the SSS system appears to be profitable and the greatest uncertainty arises from the calculation of saved lives. Each SSS will on average generate a profit of approximately 250,000 SEK annually.
4

Tropical North Atlantic Hydrologic Cycle Variability in the Florida Straits During the Last Ice Age

Them, Theodore 2012 August 1900 (has links)
Abrupt, millennial-scale climate oscillations, known as Dansgaard-Oeschger (D-O) cycles, characterized the climate system during the last ice age. Proxy evidence suggests these climate oscillations resulted in global-scale reorganizations in the hydrological cycle. For this study, Mg/Ca-paleothermometry and stable isotope measurements were combined on the planktonic foraminifera Globigerinoides ruber (white variety) from Florida Straits sediment core KNR166-2 JPC26 (24*19.61'N, 83*15.14'W; 546 m depth) to reconstruct a high-resolution record of sea surface temperature and delta18OSW (a proxy for upper water column salinity) during Marine Isotope Stages 2 and 3 from 20-35.45 ka BP. As additional proxies for upper water column salinity change, Ba/Ca ratios in G. ruber were also measured to determine the relative contribution of local riverine input on the delta18OSW record and a faunal abundance count record of the planktonic foraminifera N. dutertrei abundance was developed. These results show that rapid upper water column salinity changes occurred across D-O events in the Florida Straits, coeval with climate change in the high-latitude North Atlantic. Furthermore, the G. ruber Ba/Ca record suggests that riverine-derived meltwater from the Gulf of Mexico did not significantly impact surface salinity in the Florida current, calling into question the role of Mississippi River discharge on Atlantic Meridional Overturning Circulation (AMOC) during MIS 2 and 3. Instead, the most likely cause of MIS 2 and 3 salinity changes in the Florida Straits were variations in the strength and position of the Intertropical Convergence Zone. Finally, the timing of surface salinity change was compared with the benthic delta18OC record from the same core. A recent study showed that benthic delta18OC changes on the Florida Margin can be combined with contemporaneous records from the Bahamas Margin to reconstruct Florida Current transport related to AMOC variability. These results show that atmospheric circulation changes lead AMOC changes on the transition out of cold stadial events, suggesting the trigger for these abrupt climate events may reside in the tropics rather than in the high-latitude North Atlantic as previously thought.
5

Evaluation of Nutritional Adequacy and Symptom Improvement During Implementation of the Low-FODMAP Diet in Individuals with Irritable Bowel Syndrome

Richards, Julie Ann 14 August 2018 (has links)
No description available.
6

Evaluation de la radiothérapie vectorisée à l’aide de nanocapsules lipidiques chargées en rhénium-188 pour le traitement du glioblastome : investigation des modalités d’administrations locales / Evaluation of nanovectorized radiotherapy using 188Re-lipid nanocapsules for glioblastoma treatment : investigation on local deliveries’ modalities.

Cikankowitz, Annabelle 10 December 2015 (has links)
Les glioblastomes sont des tumeurs gliales de hautgrade qui restent incurables de nos jours. Le traitement recommandé (résection chirurgicale suivie d’un traitement de radiothérapie externe associé à la chimiothérapie) conduit à une augmentation de la médiane de survie des patients de quelques mois. De nouvelles stratégies notamment dans le champ des nanomédecines véhiculant un radioélément (émetteur ou ) ont été évaluées en clinique. La première partie,après avoir dressé l’état des lieux des technologies utilisées dans ce domaine, rend compte des critères importants à prendre en compte que sont le choix du radioélément, les modalités d’administration et les vecteurs utilisés. Elle se conclut par une présentation des études précliniques en cours dont l’utilisation de nanovecteurs encapsulant un radioisotope : lesLNC188Re-SSS. La deuxième partie illustre l’application thérapeutique sur un modèle murin de xénogreffe et montre une éradication de la tumeur initiale suite à un protocole personnalisé d’injection fractionnée par convection-enhanced delivery. Elle décrit également la distribution des LNC ainsi que les effets directs des radiations sur les cellules tumorales (cellules géantes atypiques, supposées polyploïdes), accompagnés par un infiltrat inflammatoire (immunité innée). Une évaluation complémentaire sur modèle murin GL261 a été réalisée et constitue la troisième partie de cette thèse. Le transfert de ces résultats à l’application clinique pourrait être facilité par le recours à un modèle canin de gliome spontané homologue à celui de l’homme, dont ce travail prépare l’utilisation, dans le but de valider les procédures d’injection intracérébrales automatisées. / High grade glial brain tumors are defined as glioblastomas. Nowadays, they are incurable. The current therapeutic purposal (surgical resection, external radiotherapy and chemotherapy) doesn’t extend the patients median survival time up to a few months. Newstrategies as nanomedicines loaded with a radionuclide( or  emitter) have been evaluated in clinical trials. As tate of the art of this domain’s technologies is described in a first part which analyses the important criteria to take account in vectorized radiotherapy like the radionuclides, the route of administration and the vectors used. Then, it is concluded with a presentation of preclinical on going studies as the use of nanovectors loaded with a radioisotope : the LNC188Re-SSS. The second part illustrates the therapeutical strategy application on a xenograft mice model. The data showan eradication of the tumor mass of treated mice withthe personalized convection-enhanced delivery offractionated radiotherapy. Furthermore, it describes the LNC distribution and the direct radiation effects on tumor cells (atypical giant cells, polyploïdy) supported by an inflammatory infiltration (innate immune effectors). An evaluation on the GL261 mice model has been realized and concerns the third part of this thesis. In perspectives, the transfer of these data to clinical trials could be facilitated thanks to the dog spontaneous glioma model. This tumor share characteristics with the human neoplasma. Finally, this work will aim to validate the automated intracranial injection procedures.
7

Les nanocapsules lipidiques chargées en Rhénium-188 : nouvel outil pour la radiothérapie interne du carcinome hépatocellulaire et du gliome

Vanpouille-Box, Claire 03 February 2011 (has links) (PDF)
La radiothérapie implique de limiter l'irradiation des tissus sains. Dans ce but, des nanocapsules lipidiques chargées en complexes lipophile de rhénium-188 (NCL188Re-SSS) ont été utilisées afin de créer une irradiation localisée après injection intra-tumorale. Nous avons ainsi évalué la faisabilité d'une radiothérapie interne après injection intra-hépatique de NCL188Re-SSS pour le traitement du carcinome hépatocellulaire (CHC) et, dans un deuxième temps, étudié l'efficacité d'un fractionnement de la dose radioactive après injections intra-crâniennes répétées pour le traitement des gliomes. La première partie de ce travail décrit l'intérêt d'une radiothérapie interne via les NCL188Re-SSS pour le traitement du CHC avec une augmentation de la médiane de survie jusqu'à 107% dans un modèle CHC chimio-induit chez le rat. Dans une seconde partie, nous avons pu démontrer un bénéfice majeur, sur un modèle de gliome, avec 83% des animaux long-survivants. Cette efficacité thérapeutique pourrait s'expliquer par la mise en place d'une réponse immunitaire adaptative avec recrutement local de cellules immunitaires effectrices (CD4+, CD8+...). En revanche, les essais d'une radiothérapie interne nanovectorisée sur un modèle de rat peu immunogène et radiorésistant (modèle tumoral F98) ont montré des bénéfices moindres en terme de survie. Pour stimuler la réponse immunitaire anti-tumorale et optimiser l'efficacité thérapeutique, nous avons évalué la combinaison d'une radiothérapie interne nanovectorisée et d'une vaccination par cellules F98 irradiées. Un recrutement des cellules immunitaires effectrices a été observé, cependant, l'efficacité thérapeutique n'a pas été augmentée. Les perspectives qu'offre ce travail sont de deux ordres : évaluer l'impact du processus angiogénique dans le cas du modèle CHC et stimuler le système immunitaire en association avec la radiothérapie interne pour le modèle de gliome.
8

Objektutbyte med hjälp av 3D grafik med fokus på mänskliga kroppsdelar

Orrby, Filip January 2007 (has links)
<p>I denna uppsats beskrivs metoder för att skapa en arm i 3D samt att lägga in den i ett foto där den ersätter en riktigt arm. Anledningen till detta är att kunna skapa effekter i filmer och bilder som inte är möjliga med analog teknik. I denna uppsats kan man läsa om tekniker som används i varje del av utvecklingsprocessen och problem som uppstår samt lösningar och tips. I uppgiften finns det med delar som Modellering, Texturering, Rendering, Kamera Matchmoving och Compositing.</p>
9

Efficient Simulation and Rendering of Sub-surface Scattering

Tsirikoglou, Apostolia January 2013 (has links)
In this thesis, a new improved V-Ray subsurface scattering shader based on the improved diffusion theory is proposed. The new shader supports the better dipole and the quantized diffusion reflectance model for layered translucent materials. These new implemented models build on previous diffusion BSSRDFs and in the case of quantized diffusion uses an extended source function for the material layer. One of the main contributions and significant improvement over V-Ray’s existing subsurface scattering shader is the front and back subsurface scattering separation. This was achieved by dividing the illumination map that is used to calculate each shading’s point color, in two parts: the front part that comes of front lighting and the back one that comes of back lighting. Thus, the subsurface scattering layer can be divided in its consisting parts and each of them can be controlled, weighted and used independently. Finally, the project’s outcome is a new V-Ray material that provides all the above improvements in an intuitive, practical and efficient shader with several intuitive algorithm and light map controls, where artists can create subsurface scattering effects through three subsurface scattering layers.
10

An Exploration of the Relationship between Supervision and Leadership among Middle Managers in Student Affairs Administration

Hall-Jones, Jennifer L. 25 July 2011 (has links)
No description available.

Page generated in 0.0214 seconds