• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 13
  • 5
  • 1
  • Tagged with
  • 48
  • 48
  • 37
  • 23
  • 20
  • 14
  • 14
  • 11
  • 10
  • 10
  • 8
  • 8
  • 8
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Metodologia analítica para determinação de triclosan e clorofenois por cromatografia a líquido de alta eficiência (HPLC) e cromatografia por injeção seqüencial (SIC) com uso de coluna monolítica e empacotada / Methodologies for the determination of triclosan and chlorophenols by high performance liquid chromatography (HPLC) and sequential injection chromatography (SIC) using packed and monolithic columns

Garcia, Ausberta Jesús Cabezas 06 December 2011 (has links)
Foram desenvolvidas metodologias de cromatografia a líquido de fase reversa baseadas em injeção sequencial (SIC) e em cromatografia a líquido de alta eficiência (HPLC) para determinação de triclosan em amostras de produtos de higiene pessoal e em estudos de adsorção em argilominerais naturais e modificados, visando determinar parâmetros de adsorção de triclosan frente a alguns de seus metabólitos. A determinação de triclosan em enxaguadores bucais foi realizada por SIC com eluição isocrática usando fase móvel constituída por acetonitrila: tampão fosfato de trietilamina 70 mM pH 3,5 na proporção 70:30 (v v-1), obtendo-se limites de detecção e de quantificação de 0,22 e 0,72 mg L-1, respectivamente. Taxas de recuperação entre 96 e 98% foram obtidas da aplicação a amostras reais, sendo que os resultados obtidos pelo método proposto não apresentaram evidências de diferenças estatisticamente significativas em comparação a uma metodologia de referência baseada em HPLC com coluna empacotada. A separação de triclosan (TCS), 2-clorofenol (2-CP), 2,4-diclorofenol (2,4-DCP), 2,4,6-triclorofenol (2,4,6-TCP), 2,3,4-triclorofenol (2,3,4-TCP) e metiltriclosan (MTCS) foi estudada por SIC, obtendo-se a separação de TCS, 2-CP, 2,4-DCP e 2,4,6-TCP com duas etapas de eluição isocrática, a primeira delas com fase móvel 60:40 (v v-1) metanol: tampão acetato de amônio 20 mM (pH 5,5) seguida de eluição com fase móvel 70:30 (v v-1) metanol : tampão acetato de amônio 20 mM (pH 5,5). Nesse caso, os isômeros 2,4,6-TCP e 2,3,4-TCP coeluem. Metiltriclosan, o menos polar desses compostos, pode ser separado de TCS com etapas subseqüentes de eluição. Os métodos foram aplicados para estudar a adsorção de triclosan e seus metabólitos 2,4-DCP, 2,4,6-TCP e metiltriclosan em montmorilonita homoiônica (K+) e modificada com sal de hexadeciltrimetilamônio (HDTMA), observando-se forte adsorção de triclosan e metiltriclosan em comparação a 2-CP, 2,4-DCP e 2,4,6-TCP. A incorporação de HDTMA no argilomineral causou significativo aumento da capacidade de adsorção desses metabólitos, determinada a partir do ajuste dos dados experimentais à equação linearizada de Langmuir, observando-se que a ordem de adsorção é 2,4,6-TCP > 2,4-DCP > 2-CP / Reversed-phase liquid chromatography methodologies based on sequential injection (SIC) and high performance liquid chromatography (HPLC) have been developed for determination of triclosan in samples of personal hygiene products and in studies of adsorption on natural and modified clay minerals aiming to determine kinetic and thermodynamic parameters of adsorption of triclosan in comparison with some of its metabolites. The determination of triclosan in oral rinses with SIC was performed by isocratic elution using a mobile phase of acetonitrile : 70 mM triethylamine phosphate buffer pH 3.5 at the ratio 70:30 (v v-1), obtaining limits of detection and quantification of 0.22 and 0.72 mg L-1, respectively. Recovery rates between 96 and 98 % were obtained from the application to commercial samples, and the results obtained by the proposed method showed no evidence of statistically significant differences compared to the reference methodology based on HPLC with packed column. The separation of triclosan (TCS), 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4 trichlorophenol (2,3,4-TCP) and methyltriclosan (MTCS) was studied by SIC, resulting in the separation of TCS, 2-CP, 2,4-DCP and 2,4,6-TCP with two isocratic elution steps, the first of them with a mobile phase 60:40 (v v-1) methanol: 20 mM ammonium acetate buffer (pH 5.5) followed by elution with 70:30 (v v-1) mobile phase of methanol : 20 mM ammonium acetate buffer (pH 5.5). In this case, the isomers 2,4,6-TCP and 2,3,4-TCP coeluted. Methyltriclosan, the less polar of these compounds, can be separated from TCS with subsequent elution steps. The methods were applied to study the adsorption of triclosan and its metabolites 2-CP, 2,4-DCP, 2,4,6-TCP and methyltriclosan on homoionic montmorillonite (K+) as well as in hexadecyltrimethylammonium salt (HDTMA) modified montmorillonite, noticing a stronger adsorption of triclosan and methyltriclosan compared with 2-CP, 2,4-DCP and 2,4,6-TCP. Incorporation of HDTMA in the clay mineral caused significant increase in adsorption capacity of these metabolites. This capacity was determined by fitting the experimental data to the linearized Langmuir equation. The adsorption order was 2,4,6-TCP > 2,4-DCP > 2-CP.
42

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Batista, Alex Domingues 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
43

Desenvolvimento de processo para incorporação da etapa de otimização de parâmetros analíticos em procedimentos automatizados de análises por injeção sequencial

Soares, Vitória Regina Bispo January 2009 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-08-31T12:55:32Z No. of bitstreams: 1 Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-02T15:48:05Z (GMT) No. of bitstreams: 1 Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / Made available in DSpace on 2016-09-02T15:48:05Z (GMT). No. of bitstreams: 1 Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / CNPq / Para aumentar o nível de automatização no desenvolvimento de procedimentos analíticos em sistemas de análises por injeção sequencial foi proposta uma rotina em linguagem QuickBasic que permitia incorporar a etapa de otimização multivariada como uma das etapas do processo analítico, simplificando o gerenciamento do sistema. A rotina foi desenvolvida para sistemas de análises por injeção sequencial, uma vez que esta estratégia de análises em fluxo pode executar diferentes procedimentos sem reconfiguração do sistema. O processo automatizado de otimização, calibração e medida foi aplicado para as determinações espectrofotométricas de ferro total e de captopril em medicamentos, empregando os métodos da 1,10-o-fenantrolina e do acoplamento com o radical iminoquinona, respectivamente. Para rotina de otimização desenvolvida foi selecionado o sinal líquido como resposta e a intervenção do operador se restringiu a selecionar as variáveis do sistema sob otimização, definir os domínios experimentais de cada variável e escolher o desenho experimental a ser executado. Entretanto, caso as condições ótimas não fossem encontradas no domínio experimental selecionado a rotina foi programada de modo a sugerir ao operador os deslocamentos que deveriam ser feitos nos domínios experimentais. Os fatores investigados para a determinação de ferro total em amostras de fortificantes foram os volumes amostrados dos reagentes e a vazão da solução transportadora, enquanto que para o captopril foram investigados os volumes amostrados dos reagentes, a acidez da solução do oxidante e da solução da amina aromática, além da vazão da solução transportadora. Nas condições otimizadas os graus de sopreposição de zonas para ambos os procedimentos variaram entre 0,79 e 1, indicando a eficiente mistura das soluções das amostras e reagentes no percurso analítico. O procedimento SIA otimizado para a determinação do teor de ferro total em fortificantes apresentou baixa dispersão (<2%), limite de quantificação de 1,43 mg L-1 , com consumo de 0,7 mg de 1,10-o- fenantrolina e 6 mg de ácido ascórbico por determinação. A freqüência analítica foi de 60 determinações h-1 e os resultados obtidos para diferentes amostras de fortificantes foram comparados com o mesmo método em batelada e não apresentaram diferenças significativas para 95% de confiabilidade. Trinta determinações de captopril em produtos farmacêuticos por hora de trabalho foram executadas pelo procedimento de análise por injeção seqüencial otimizado consumindo 0,15 mg de sulfato de N-N-dimetil-p-fenilodiamina (DMPD) e 4 mg de FeCl3.6H2O por determinação. Faixa linear de trabalho entre 2,65 e 100 mg L-1 e boa precisão (ca. 1%) foram também obtidas. Os teores de captopril em amostras de produtos farmacêuticos foram determinados pelo procedimento proposto e os resultados, quando comparados com o método iodométrico de referência, não apresentaram diferenças significativa para 95% de confiança / A QuickBasic routine was proposed to increase the automatization in the development of analytical process for sequential injection analysis system in order to permit the inclusion of multivariated optimization as one of the steps of analytical process leading to simplify the system management. The routine was developed for sequential injection analysis once this flow analysis strategy can perform diverse analytical procedures in the same manifold. The automatized process for optimization, calibration and measurement was applied to determine the total iron concentration in pharmaceutical formulations by 1,10-o-phenantroline spectrophotometric method, as well as captopril in pharmaceutical formulations based on coupling reaction with iminoquinone radical. Sensitivity (net signal) was selected as dependent parameter for the optimization step and the analyst action was limited to select the parameters to be optimized and the experimental design to be used as well to define the experimental domains of all parameters. A decision of the analyst was also expected in the cases where the optimal conditions were not attained in the domains previously selected and, once new domains are suggested by the software, a new sequence of experiments will be carried out with human agreement. Aliquots volumes of reagents and carrier solution flow rate were the parameters evaluated for total iron determination in supplements, while the acidity and volumes of reagents solutions and the flow rate of carrier solution were optimized for captopril determination flow procedure. For both analytical procedures in the optimized conditions the index of zone overlapping was varied from 0.79 and 1, suggesting an efficient mixture of solutions in the analytical path. The optimized SIA procedure for total iron determination in supplement samples has low dispersion (<2%), limit of quantification of 1.43 mg L-1, leading to consume 0.7 mg of 1,10-o-phenantroline and 6 mg of ascorbic acid per determination. An analytical throughput of 60 determinations h-1 was estimated and no significant difference (95% confidence level) was observed by comparing the results obtained by the flow method in optimized conditions and those obtained by the spectrophotometric procedure in batch mode. Thirty captopril determinations in pharmaceutical formulations per hour were carried out by employing the optimized sequential injection analysis procedure, consuming 0.15 mg of N,N-dimethyl-p-phenylenediamine (DMPD) and 4 mg of FeCl3.6H2O. Linear range from 2.65 to 100 mg L-1 with high precision (ca. 1%) was also obtained and no significant differences (95% confidence level) were observed by comparing the optimized flow procedure with the iodometric reference method.
44

Metodologia analítica para determinação de triclosan e clorofenois por cromatografia a líquido de alta eficiência (HPLC) e cromatografia por injeção seqüencial (SIC) com uso de coluna monolítica e empacotada / Methodologies for the determination of triclosan and chlorophenols by high performance liquid chromatography (HPLC) and sequential injection chromatography (SIC) using packed and monolithic columns

Ausberta Jesús Cabezas Garcia 06 December 2011 (has links)
Foram desenvolvidas metodologias de cromatografia a líquido de fase reversa baseadas em injeção sequencial (SIC) e em cromatografia a líquido de alta eficiência (HPLC) para determinação de triclosan em amostras de produtos de higiene pessoal e em estudos de adsorção em argilominerais naturais e modificados, visando determinar parâmetros de adsorção de triclosan frente a alguns de seus metabólitos. A determinação de triclosan em enxaguadores bucais foi realizada por SIC com eluição isocrática usando fase móvel constituída por acetonitrila: tampão fosfato de trietilamina 70 mM pH 3,5 na proporção 70:30 (v v-1), obtendo-se limites de detecção e de quantificação de 0,22 e 0,72 mg L-1, respectivamente. Taxas de recuperação entre 96 e 98% foram obtidas da aplicação a amostras reais, sendo que os resultados obtidos pelo método proposto não apresentaram evidências de diferenças estatisticamente significativas em comparação a uma metodologia de referência baseada em HPLC com coluna empacotada. A separação de triclosan (TCS), 2-clorofenol (2-CP), 2,4-diclorofenol (2,4-DCP), 2,4,6-triclorofenol (2,4,6-TCP), 2,3,4-triclorofenol (2,3,4-TCP) e metiltriclosan (MTCS) foi estudada por SIC, obtendo-se a separação de TCS, 2-CP, 2,4-DCP e 2,4,6-TCP com duas etapas de eluição isocrática, a primeira delas com fase móvel 60:40 (v v-1) metanol: tampão acetato de amônio 20 mM (pH 5,5) seguida de eluição com fase móvel 70:30 (v v-1) metanol : tampão acetato de amônio 20 mM (pH 5,5). Nesse caso, os isômeros 2,4,6-TCP e 2,3,4-TCP coeluem. Metiltriclosan, o menos polar desses compostos, pode ser separado de TCS com etapas subseqüentes de eluição. Os métodos foram aplicados para estudar a adsorção de triclosan e seus metabólitos 2,4-DCP, 2,4,6-TCP e metiltriclosan em montmorilonita homoiônica (K+) e modificada com sal de hexadeciltrimetilamônio (HDTMA), observando-se forte adsorção de triclosan e metiltriclosan em comparação a 2-CP, 2,4-DCP e 2,4,6-TCP. A incorporação de HDTMA no argilomineral causou significativo aumento da capacidade de adsorção desses metabólitos, determinada a partir do ajuste dos dados experimentais à equação linearizada de Langmuir, observando-se que a ordem de adsorção é 2,4,6-TCP > 2,4-DCP > 2-CP / Reversed-phase liquid chromatography methodologies based on sequential injection (SIC) and high performance liquid chromatography (HPLC) have been developed for determination of triclosan in samples of personal hygiene products and in studies of adsorption on natural and modified clay minerals aiming to determine kinetic and thermodynamic parameters of adsorption of triclosan in comparison with some of its metabolites. The determination of triclosan in oral rinses with SIC was performed by isocratic elution using a mobile phase of acetonitrile : 70 mM triethylamine phosphate buffer pH 3.5 at the ratio 70:30 (v v-1), obtaining limits of detection and quantification of 0.22 and 0.72 mg L-1, respectively. Recovery rates between 96 and 98 % were obtained from the application to commercial samples, and the results obtained by the proposed method showed no evidence of statistically significant differences compared to the reference methodology based on HPLC with packed column. The separation of triclosan (TCS), 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4 trichlorophenol (2,3,4-TCP) and methyltriclosan (MTCS) was studied by SIC, resulting in the separation of TCS, 2-CP, 2,4-DCP and 2,4,6-TCP with two isocratic elution steps, the first of them with a mobile phase 60:40 (v v-1) methanol: 20 mM ammonium acetate buffer (pH 5.5) followed by elution with 70:30 (v v-1) mobile phase of methanol : 20 mM ammonium acetate buffer (pH 5.5). In this case, the isomers 2,4,6-TCP and 2,3,4-TCP coeluted. Methyltriclosan, the less polar of these compounds, can be separated from TCS with subsequent elution steps. The methods were applied to study the adsorption of triclosan and its metabolites 2-CP, 2,4-DCP, 2,4,6-TCP and methyltriclosan on homoionic montmorillonite (K+) as well as in hexadecyltrimethylammonium salt (HDTMA) modified montmorillonite, noticing a stronger adsorption of triclosan and methyltriclosan compared with 2-CP, 2,4-DCP and 2,4,6-TCP. Incorporation of HDTMA in the clay mineral caused significant increase in adsorption capacity of these metabolites. This capacity was determined by fitting the experimental data to the linearized Langmuir equation. The adsorption order was 2,4,6-TCP > 2,4-DCP > 2-CP.
45

Cromatografia a líquido por injeção sequencial para a determinação de herbicidas triazínicos e metabólitos da atrazina explorando o uso de cela de longo caminho óptico e monitoramento on-line em estudos de adsorção / Sequential injection liquid chromatography for the determination of triazine herbicides and metabolites of atrazine exploring the use of long optical pathlength flow cell and on line monitoring of adsorption studies

Ricardo de Prá Urio 16 May 2011 (has links)
Estudou-se o emprego da Cromatografia a Líquido por Injeção Seqüencial (SIC) explorando o uso de uma cela de longo caminho óptico com guia de onda (LCW) de 100 cm para a melhora dos limites de detecção (LOD) e quantificação (LOQ) na determinação de atrazina (ATR), propazina (PRO) e simazina (SIM). Para isto, utilizou-se uma fase móvel com composição de 44:56 (v v-1) metanol : tampão acetato de amônio 1,25 mM, pH 4,7, coluna monolítica e a detecção espectrofotométrica em 238 nm. Obtiveram-se valores de LOD e LOQ, respectivamente, de 1,76 e 5,86 &#181;g L-1 para ATR, 4,51 e 15 &#181;g L-1 para PRO e 2,25 e 7,5 &#181;g L-1 para SIM. Com o emprego da cela de longo caminho óptico os valores de LOD ficaram abaixo dos recomendados pela US-EPA, que permite para águas potáveis uma concentração de 3 &#181;g L-1 para ATR, 4 &#181;g L-1 para SIM e 10 &#181;g L-1 para PRO. Realizaram-se estudos de adsorção de SIM, PRO e ATR e seus metabólitos desisopropilatrazina (DIA), desetilatrazina (DEA) e 2-hidroxiatrazina (HAT) em solo, ácido húmico e solo modificado com ácido húmico. Para isso foi utilizado um sistema de monitoramento on-line composto por um filtro tangencial e uma bomba peristáltica para circulação da suspensão. Foram realizados estudos cinéticos em duas etapas e, em ambas, foi utilizado um mix dos compostos com concentração inicial de 1,0 mg L-1 e gradiente de eluição passo a passo para a separação dos compostos utilizando três fases móveis com composições de 15 ou 28, 40 e 50% (v v-1) metanol : tampão acetato de amônio 1,25 mM pH 4,7. Na primeira etapa o tempo de contato entre triazinas e adsorventes foi de 90 min. Na segunda etapa foi utilizado apenas o solo como adsorvente e o tempo de contato foi de 24 h. Para a primeira etapa do estudo só foi possível aplicar modelo cinético de pseudo-segunda ordem, o qual permitiu estimar os valores de massa adsorvida de triazina por massa de adsorvente, sendo que o ácido húmico é o material com maior capacidade adsortiva (1470 ± 43&#181;g g-1 para DIA a 2380 ± 51 &#181;g g-1 para PRO). O composto mais adsorvido em solo é PRO (26,5 ± 0,1 &#181;g g-1). A presença de ácido húmico no solo aumentou a adsorção de ATR (de 19,4 ± 0,7 para 23 ± 2 &#181;g g-1), de HAT (10,9 ± 0,7 para 18 ± 2 &#181;g g-1) e de PRO (26,5 ± 0,7 para 29,8 ±0,2 &#181;g g-1), mas diminuiu a adsorção de SIM e não afetou DIA e DEA. No estudo com tempo de contato de 24 h foi possível aplicar modelos de pseudo-primeira e segunda ordem. Os resultados obtidos confirmaram a maior adsorção de PRO, seguidos da ATR. HAT, SIM, DEA e DIA apresentaram as menores taxas de adsorção em solo, sendo que os dois últimos apresentaram uma tendência de dessorção após 4 h de contato, tendo maior potencial de lixiviação para corpos d\'água próximos aos locais de aplicação. / This work describes the use of Sequential Injection Liquid Chromatography (SIC) coupled to a long path length optical flow cell with 100 cm long Liquid Core Waveguide (LCW) to improve the limits of detection (LOD) and quantification (LOQ) for determination of atrazine (ATR), propazine (PRO) and simazine (SIM). Separation was achieved with a mobile phase composition of 44:56 (v v-1) methanol:1.25 mM ammonium acetate buffer, pH 4.7, monolithic column and spectrophotometric detection at 238 nm. The values of LOD and LOQ were, respectively, 1.76 and 5.86 &#181;g L-1 for ATR, 4.51 and 15 &#181;g L-1 for PRO and 2.25 and 7.5 &#181;g L-1 for SIM. The LOD values achieved with the employment of long optical path cell were lower than those recommended by US-EPA, which allows for drinking water, maximum concentration levels of 3 &#181;g L-1 for ATR, 4 &#181;g L-1 for SIM and 10 &#181;g L-1 for PRO. Adsorption of SIM, PRO and ATR, as well as their metabolites desisopropylatrazine (DIA), desethylatrazine (DEA) and 2-hidroxyatrazine (HAT) on soil, humic acid and soil modified with humic acidic was studied. An on-line monitoring system was assembled, composed of a tangential filter and a peristaltic pump for circulation of the suspension. Kinetic studies were carried out in two steps, and in both, it was used a mix of compounds with initial concentration of 1,0 mg L-1 and a stepwise gradient elution for separation of the compounds using three mobile phases with compositions of 15 or 28, 40 and 50% (v v-1) methanol: 1.25 mM ammonium acetate buffer, pH 4.7. In the first step the contact time between triazines and adsorbents was 90 minutes. In a second study made only with soil, the contact time was 24 h. Data obtained in the first stage of the study was only fitted to pseudo-second order kinetic equation, which allowed one to estimate the values of the adsorbed mass of triazine per mass of adsorbent. Humic acid was the material with higher adsorptive capacity (from 1470 ± 43 &#181;g g-1 for DIA to 2380 ± 50 &#181;g g-1 for PRO). In soil, PRO exhibited the highest adsorption (26.5 ± 0.1 &#181;g g-1). The presence of humic acid in the soil increased adsorption of ATR (19.4±0.7 to 23±2 &#181;g g-1), HAT (10.9 ± 0.7 to 18 ± 2 &#181;g g-1) and PRO (26.5 ± 0.7 to 29.8 ± 0.2 &#181;g g-1), but decreased adsorption of SIM, not affecting DIA and DEA. In the study with contact time of 24 h, it was possible apply pseudo-first and pseudo-second order equations for SIM, ATR and PRO. The results confirmed the greatest adsorption of PRO, followed by ATR. HAT, SIM, DEA and DIA had low rates of adsorption on soil, the latter two showed a trend of desorption after 4 h of contact, having the greatest potential for leaching to water bodies near to the places of application.
46

A derivatização na determinação de proteínas e aminoácidos em fluidos biológicos / Derivatization in the determination of proteins and amino acids in biological fluids

Orlando Guarilha Junior 06 June 2003 (has links)
No presente trabalho são apresentadas análises de amostras de proteínas totais e aminoácidos empregando-se os reagentes p-benzoquinona e tetraamin cobre (II). No caso do reagente p-benzoquinona, as análises foram feitas através de um sistema inédito em fluxo, no qual a mistura reacional passava através de um reator composto de um tubo capilar de aço inoxidável aquecido num banho de glicerina. Os derivados formados passavam através de uma cela de fluxo acoplada a um espectrofotômetro, onde eram feitas as leituras das absorbâncias. Este método se mostrou mais rápido em relação àquele feito em banho-maria. A utilização de um sistema de análise por injeção em fluxo (FIA) com o reagente tetraamin cobre (II), permitiu que as análises fossem feitas de forma rápida, a baixo custo e com a vantagem de não necessitarem de aquecimento, como no caso da p-benzoquinona. Os resultados das análises de amostras de albumina humana obtidos em ambos os métodos acima apresentaram boa concordância quando comparados àqueles obtidos pelo método Kjeldahl para as mesmas amostras. / This work describes two methods for analysis of total proteins and aminoacids using both p-benzoquinone (PBQ) and tetraamin copper (II) reagents. With the p-benzoquinone reagent the method was performed by an original flow system made with stainless steel capillary tubing, conveniently heated into a glycerin bath, where the reactional mixture travels in its way to the detector. The derivate products are carried out to a flow cell adjusted to a spectrophotometer where the absorbances are measured. This method was efficient, with a fair cost, and providing results very faster than in the batch mode of operation. The second method, using the tetraamin copper (II) reagent, was performed by a common flow injection system (FIA). When compared with the PBQ method, the FIA tetramin copper (II) method was also rapid, efficient, with a fair cost and with the great advantage of simplicity, once it is performed at room temperature. The results obtained with human albumine samples using both methods are in agreement with those ones obtained by the Kjeldahl method for the same samples.
47

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Alex Domingues Batista 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
48

Développement d’un lab-on-chip pour la mesure d’acidité libre de solutions chargées en cations hydrolysables / Development of a lab-on-chip for free acidity measurement in aqueous solutions containing hydrolytic cations

Neri Quiroz, José Antonio 25 November 2016 (has links)
Une étude conjointe du CEA et d'AREVA la Hague a montré qu'une des voies d'amélioration majeure des usines de traitement/recyclage du combustible nucléaire usagé, actuelles et futures, concerné le domaine de l'analyse. En effet, le suivi et le pilotage des procédés déployés dans ces usines nécessitent de nombreuses analyses générant de grandes quantités d'effluents radioactifs. Réduire les volumes mis en jeu lors de ces analyses permettrait donc de réduire la nocivité des échantillons et des effluents et donc d'accroitre la sureté pour le personnel et de réduire l'impact sur l'environnement et le coût de fonctionnement des usines. Parmi toutes les analyses effectuées, la mesure d'acidité libre est la plus fréquente, car c'est un paramètre indispensable pour pouvoir piloter correctement le procédé. C'est pourquoi, ces travaux de thèse ont abouti à l'amélioration de la méthode de mesure via une réduction d'échelle de l'analyse et une automatisation du protocole de mesure. Deux voies ont été étudiées : - le titrage par injection séquentielle (SIA), qui est un dispositif de 25 L de volume et qui par rapport à la méthode d'analyse de référence, réduit 1000 fois le volume d'échantillon nécessaire à l'analyse, 8 fois le temps d'analyse et 40 fois le volume d'effluents générés. - le titrage ballist-mix emploie un dispositif microfluidique qui, après intégration et réduction des composants, peut atteindre un volume de 25 mL et offre des performances analytiques comparables à celles obtenues en SIA. La méthode par SIA a été validée sur des solutions chargées en uranium alors que la technologie utilisée pour développer les titrages ballist-mix est en cours de validation. Cependant le principe opératoire du titrage ballist-mix est plus avantageux puisqu'il simplifie le travail de développement analytique du fait de la possibilité de simuler en avance les phénomènes physicochimiques ayant lieu lors du titrage / A joint study between the CEA and Areva La Hague has shown that chemical analysis is a crucial parameter for achieving a better performance in present and future spent nuclear fuel reprocessing plants. In fact, each plant’s process monitoring and control require a significant amount of laboratory analysis leading in overall to a considerable amount of nuclear waste. Hence, reducing the sample’s required volume for analysis would reduce its toxicity and subsequent waste, therefore increasing personnel safety, decreasing the environmental impact and the plant’s operation cost. Among the process control analytical workload, the free acidity measurement has been identified as a key analysis due to its measurement frequency. For this reason, the main objective of this research has been focused in the improvement of a reference method for free acidity measurement. The following work has been divided in two main studies seeking for the reduction of the sample volume and the automation of the analytical method protocol: - Sequential Injection Analysis (SIA) titration, whose application requires the employment of a device occupying a 25 L space, and which reduces 1000 fold the sample volume per analysis, 8 times the analysis time and 40 fold the amount of waste generated when compared to the reference analytical method. - Ballist-mix titration, whose analytical performance is equivalent to the SIA titration, but whose implementation is done inside a microfluidic device occupying a volume as low as 25 mL after integration of all of the elements needed for analysis. At the present time, the SIA titration has been validated using nitric acid samples containing uranyl cations, whereas the ballist-mix titration is being validated with the same sample conditions. However, this last analytical technique features a simplified operating principle which allows the user to shorten the analytical development process by opening the possibility to simulate the process before any experimentation

Page generated in 0.0907 seconds