Induction Motor Drives Based on Multilevel Dodecagonal and Octadecagonal Volatage Space Vectors

Mathew, K January 2013 (has links) (PDF)
For medium and high-voltage drive applications, multilevel inverters are very popular. It is due to their superior performance compared to 2-level inverters such as reduced harmonic content in the output voltage and current, lower common mode voltage and dv=dt, and lesser voltage stress on power switches. The popular circuit topologies for multilevel inverters are neutral point clamped, cascaded H-bridge and flying capacitor based circuits. There exist different combinations of these basic topologies to realize multilevel inverters with modularity, better fault tolerance, and reliability. Due to these advantages, multilevel converters are getting good acceptance from the industry, and researchers all over the world are continuously trying to improve the performance of these converters. To meet such demands, three multilevel inverter topologies are proposed in this thesis. These topologies can be used for high-power induction motor drives, and the concepts presented are also applicable for synchronous motor drives, grid-connected inverters, etc. To get nearly sinusoidal phase current waveforms, the switching frequency of the conventional inverter has to be increased. It will lead to higher switching losses and electromagnetic interference. The problem with lower switching frequency is the intro- duction of low order harmonics in phase currents and undesirable torque ripple in the motor. The 5th and 7th harmonics are dominant for hexagonal voltage space-vector based low frequency switching, and it is possible to eliminate these harmonics by dodecagonal switching. Further improvement in the waveform quality is possible by octadecagonal voltage space-vectors. In this case, the complete elimination of 11th and 13th harmonic is possible for the entire modulation range. The concepts of dodecagonal and octadecagonal voltage space-vectors are used in the proposed inverter topologies. The first topology proposed in this thesis consists of cascaded connection of two H-bridge cells. The two cells are fed from unequal DC voltage sources having a ratio of 1 : 0:366, and this inverter can produce six concentric dodecagonal voltage space- vectors. This ratio of voltages can be obtained easily from a combination of star-delta transformers, since 1 : 0:366 = ( p 3 + 1) : 1. The cascaded connection of two H-bridge cells can generate nine asymmetric pole voltage levels, and the combined three-phase inverter can produce 729 voltage space-vectors (9 9 9). From this large number of combinations, only certain voltage space-vectors are selected, which forms dodecagonal pattern. In the case of conventional multilevel inverters, the voltage space-vector diagram consists of equilateral triangles of equal size, but for the proposed inverter, the triangular regions are isosceles and are having different sizes. By properly placing the voltage space-vectors in a sampling period, it is possible to achieve lower switching frequency for the individual cells, with substantial improvement in the harmonic spectrum of the output voltage. During the experimental veri cation, the motor is operated at di erent speeds using open loop v=f control method. The samples taken are always synchronised with the start of the sector to get synchronised PWM. The number of samples per sector is decreased with increase in the fundamental frequency to limit the switching frequency. Even though many topologies are available in literature, the most preferred topology for drives application such as traction drives is the 3-level NPC structure. This implies that the industry is still looking for viable alternatives to construct multilevel inverter topologies based on available power circuits. The second work focuses on the development of a multilevel inverter for variable speed medium-voltage drive application with dodecagonal voltage space-vectors, using lesser number of switches and power sources compared to earlier implementations. It can generate three concentric 12-sided polygonal voltage space-vectors and it is based on commonly available 2-level and 3-level inverters. A simple PWM timing computation method based on the hexagonal space-vector PWM is developed. The sampled values of the three-phase reference voltages are initially converted to the timings of a two-level inverter. These timings are mapped to the dodecagonal timings using a change of basis transformation. The voltage space- vector diagram of the proposed drive consists of sixty isosceles triangular regions, and the dodecagonal timings calculated are converted to the timings of the inner triangles. A searching algorithm is used to identify the triangular region in which the reference vector is located. A front-end recti er that may be easily implemented using standard star-delta transformers is also developed, to provide near-unity power factor. To test the performance of the inverter drive, an open-loop v=f control is used on a three-phase induction motor under no-load condition. The harmonic spectra of the phase voltages were computed in order to analyse the harmonic distortion of the waveforms. The carrier frequency was kept around 1.2 KHz for the entire range of operation. If the switching frequency is decreased, the conventional hexagonal space-vector based switching introduce signifi cant 5th, 7th, 11th and 13th harmonics in the phase currents. Out of these dominant harmonics, the 5th and 7th harmonics can be completely suppressed using dodecagonal voltage space-vector based switching as observed in the first and second work. It is also possible to remove the 11th and the 13th harmonics by using voltage space-vectors with 18 sides. The last topology is based on multilevel octadecagonal (18-sided polygon) voltage space-vectors, and it has better harmonic performance than the previously mentioned topologies. Here, a multilevel inverter system capable of producing three octadecagonal voltage space-vectors is proposed for the fi rst time, along with a simple timing calculation method. The conventional three-level inverters are only required to construct the proposed drive. Four asymmetric power supply voltages with 0:3054Vdc, 0:3473Vdc, 0:2266Vdc and 0:1207Vdc are required for the operation of the drive, and it is the main drawback of the circuit. Generally front-end isolation transformer is essential for high-power drives and these asymmetric voltages can be easily obtained from the multiple windings of the isolation transformer. The total harmonic distortion of the phase current is improved due to the 18-sided voltage space-vector switching. The ratio of the radius of the largest polygon and its inscribing circle is cos10 = 0:985. This ratio in the case of hexagonal voltage space-vector modulation is cos30 = 0:866, which means that the range of the linear modulation for the proposed scheme is signifi cantly higher. The drive is designed for open-end winding induction motors and it has better fault tolerance. It any of the inverter fails, it can be easily bypassed and the drive will be still functional with reduced speed. Open loop v=f control and rotor flux oriented vector control schemes were used during the experimental verifi cation. TMS320F2812 DSP platform was used to execute the control code for the proposed drive schemes. For the entire range of operation, the carrier was synchronized with the fundamental. For the synchronization, the sampling period is varied dynamically so that the number of samples in a triangular region is fi xed, keeping the switching frequency around 1.2 KHz. The average execution time for the v=f code was found to be 20 S, where as for vector control it took nearly 100 S. The PWM terminals and I/O lines of the DSP is used to output the timings and the triangle number respectively. To convert the triangle number and the timings to IGBT gate drive logic, an FPGA (XC3S200) was used. A constant dead-time of 1.5 S is also implemented inside the FPGA. Opto-isolated gate drivers with desaturation protection (M57962L) were used to drive the IGBTs. Hall-effect sensors were used to measure the phase currents and DC bus voltages. An incremental shaft position encoder with 2500 pulse per revolution is also connected to the motor shaft, to measure the angular velocity. 1200 V, 75 A IGBT half-bridge module is used to realize the switches. The concepts were initially simulated and experimentally verifi ed using laboratory prototypes at low power. While these concepts maybe easily extended to higher power levels by using suitably rated devices, the control techniques presented shall still remain applicable.
2

Induction Motor Drives Based on Multilevel Dodecagonal and Octadecagonal Volatage Space Vectors

Mathew, K January 2013 (has links) (PDF)
For medium and high-voltage drive applications, multilevel inverters are very popular. It is due to their superior performance compared to 2-level inverters such as reduced harmonic content in the output voltage and current, lower common mode voltage and dv=dt, and lesser voltage stress on power switches. The popular circuit topologies for multilevel inverters are neutral point clamped, cascaded H-bridge and flying capacitor based circuits. There exist different combinations of these basic topologies to realize multilevel inverters with modularity, better fault tolerance, and reliability. Due to these advantages, multilevel converters are getting good acceptance from the industry, and researchers all over the world are continuously trying to improve the performance of these converters. To meet such demands, three multilevel inverter topologies are proposed in this thesis. These topologies can be used for high-power induction motor drives, and the concepts presented are also applicable for synchronous motor drives, grid-connected inverters, etc. To get nearly sinusoidal phase current waveforms, the switching frequency of the conventional inverter has to be increased. It will lead to higher switching losses and electromagnetic interference. The problem with lower switching frequency is the intro- duction of low order harmonics in phase currents and undesirable torque ripple in the motor. The 5th and 7th harmonics are dominant for hexagonal voltage space-vector based low frequency switching, and it is possible to eliminate these harmonics by dodecagonal switching. Further improvement in the waveform quality is possible by octadecagonal voltage space-vectors. In this case, the complete elimination of 11th and 13th harmonic is possible for the entire modulation range. The concepts of dodecagonal and octadecagonal voltage space-vectors are used in the proposed inverter topologies. The first topology proposed in this thesis consists of cascaded connection of two H-bridge cells. The two cells are fed from unequal DC voltage sources having a ratio of 1 : 0:366, and this inverter can produce six concentric dodecagonal voltage space- vectors. This ratio of voltages can be obtained easily from a combination of star-delta transformers, since 1 : 0:366 = ( p 3 + 1) : 1. The cascaded connection of two H-bridge cells can generate nine asymmetric pole voltage levels, and the combined three-phase inverter can produce 729 voltage space-vectors (9 9 9). From this large number of combinations, only certain voltage space-vectors are selected, which forms dodecagonal pattern. In the case of conventional multilevel inverters, the voltage space-vector diagram consists of equilateral triangles of equal size, but for the proposed inverter, the triangular regions are isosceles and are having different sizes. By properly placing the voltage space-vectors in a sampling period, it is possible to achieve lower switching frequency for the individual cells, with substantial improvement in the harmonic spectrum of the output voltage. During the experimental veri cation, the motor is operated at di erent speeds using open loop v=f control method. The samples taken are always synchronised with the start of the sector to get synchronised PWM. The number of samples per sector is decreased with increase in the fundamental frequency to limit the switching frequency. Even though many topologies are available in literature, the most preferred topology for drives application such as traction drives is the 3-level NPC structure. This implies that the industry is still looking for viable alternatives to construct multilevel inverter topologies based on available power circuits. The second work focuses on the development of a multilevel inverter for variable speed medium-voltage drive application with dodecagonal voltage space-vectors, using lesser number of switches and power sources compared to earlier implementations. It can generate three concentric 12-sided polygonal voltage space-vectors and it is based on commonly available 2-level and 3-level inverters. A simple PWM timing computation method based on the hexagonal space-vector PWM is developed. The sampled values of the three-phase reference voltages are initially converted to the timings of a two-level inverter. These timings are mapped to the dodecagonal timings using a change of basis transformation. The voltage space- vector diagram of the proposed drive consists of sixty isosceles triangular regions, and the dodecagonal timings calculated are converted to the timings of the inner triangles. A searching algorithm is used to identify the triangular region in which the reference vector is located. A front-end recti er that may be easily implemented using standard star-delta transformers is also developed, to provide near-unity power factor. To test the performance of the inverter drive, an open-loop v=f control is used on a three-phase induction motor under no-load condition. The harmonic spectra of the phase voltages were computed in order to analyse the harmonic distortion of the waveforms. The carrier frequency was kept around 1.2 KHz for the entire range of operation. If the switching frequency is decreased, the conventional hexagonal space-vector based switching introduce signifi cant 5th, 7th, 11th and 13th harmonics in the phase currents. Out of these dominant harmonics, the 5th and 7th harmonics can be completely suppressed using dodecagonal voltage space-vector based switching as observed in the first and second work. It is also possible to remove the 11th and the 13th harmonics by using voltage space-vectors with 18 sides. The last topology is based on multilevel octadecagonal (18-sided polygon) voltage space-vectors, and it has better harmonic performance than the previously mentioned topologies. Here, a multilevel inverter system capable of producing three octadecagonal voltage space-vectors is proposed for the fi rst time, along with a simple timing calculation method. The conventional three-level inverters are only required to construct the proposed drive. Four asymmetric power supply voltages with 0:3054Vdc, 0:3473Vdc, 0:2266Vdc and 0:1207Vdc are required for the operation of the drive, and it is the main drawback of the circuit. Generally front-end isolation transformer is essential for high-power drives and these asymmetric voltages can be easily obtained from the multiple windings of the isolation transformer. The total harmonic distortion of the phase current is improved due to the 18-sided voltage space-vector switching. The ratio of the radius of the largest polygon and its inscribing circle is cos10 = 0:985. This ratio in the case of hexagonal voltage space-vector modulation is cos30 = 0:866, which means that the range of the linear modulation for the proposed scheme is signifi cantly higher. The drive is designed for open-end winding induction motors and it has better fault tolerance. It any of the inverter fails, it can be easily bypassed and the drive will be still functional with reduced speed. Open loop v=f control and rotor flux oriented vector control schemes were used during the experimental verifi cation. TMS320F2812 DSP platform was used to execute the control code for the proposed drive schemes. For the entire range of operation, the carrier was synchronized with the fundamental. For the synchronization, the sampling period is varied dynamically so that the number of samples in a triangular region is fi xed, keeping the switching frequency around 1.2 KHz. The average execution time for the v=f code was found to be 20 S, where as for vector control it took nearly 100 S. The PWM terminals and I/O lines of the DSP is used to output the timings and the triangle number respectively. To convert the triangle number and the timings to IGBT gate drive logic, an FPGA (XC3S200) was used. A constant dead-time of 1.5 S is also implemented inside the FPGA. Opto-isolated gate drivers with desaturation protection (M57962L) were used to drive the IGBTs. Hall-effect sensors were used to measure the phase currents and DC bus voltages. An incremental shaft position encoder with 2500 pulse per revolution is also connected to the motor shaft, to measure the angular velocity. 1200 V, 75 A IGBT half-bridge module is used to realize the switches. The concepts were initially simulated and experimentally verifi ed using laboratory prototypes at low power. While these concepts maybe easily extended to higher power levels by using suitably rated devices, the control techniques presented shall still remain applicable.
3

Cálculo das sequências positiva e negativa em tempo real a partir do produto escalar de vetores espaciais: aplicações em compensadores de perturbações na rede. / Calculation of positive and negative sequences in real time by using space vectors dot products: applications to grid disturbances compensators.

Kelly Caroline Mingorancia de Carvalho 02 February 2015 (has links)
O presente trabalho pretende aplicar o método de cálculo de componentes simétricas por produtos escalares de vetores espaciais para o cálculo dos sinais de referência de compensadores de perturbação. Outras metodologias de cálculo de corrente de referência são apresentadas, analisadas e comparadas com o método implementado. Uma revisão de vetores espaciais nos sistemas abc e 0 é feita para auxílio da explicação do método de extração de componentes simétricas. O método é inicialmente apresentado de forma generalista, de modo que é realizado o cálculo de componentes de sequência positiva, negativa e zero para um harmônico de ordem h. A autora apresenta algoritmos de exemplos práticos para uso em cálculo de corrente de referência incluindo as compensações de reativos da corrente fundamental, de harmônicos pré-selecionados e de desequilíbrios de carga. O método é analisado e validado por meio de simulações e resultados experimentais. / This work applies, for a disturbance compensator, a method for the calculation of the symmetrical components based on space vectors\' dot product. Other methods are presented, analyzed and compared with the proposed method. The symmetrical components calculation method is explained using a geometrical approach in abc and 0 basis. Initially, it is presented a general method that calculates the hth order positive, negative and zero sequence components of a current or voltage signal. Then, practical examples are presented for current compensation, which includes: fundamental reactive current compensation, fundamental negative sequence compensation and pre-selected order harmonics compensation. The method is analyzed and validated by simulation and experimental results.
4

Investigations On Sensorless Vector Control Using Current Error Space Phasor And Direct Torque Control Of Induction Motor Drive Based On Hexagonal And 12-Sided Polygonal Voltage Space Vectors

Ramubhai, Patel Chintanbhai 02 1900 (has links) (PDF)
Variable-speed Induction motor drives are nowadays used for various kinds of industrial processes, transportation systems, wind turbines and household appliances in the world. The majority of drives are for general purpose speed control applications where accurate speed control is not required for entire speed range. But for high dynamic drive application, very precise and fast control of induction motor drive is essential. For such applications, sophisticated and well-performing control design is a key issue. Precise and accurate torque control of the Induction Motor (IM) can only be accomplished by vector control and direct torque control. In terms of space vector theory, vector control implies that the instantaneous torque is controlled by way of the stator current vector that is orthogonal to the rotor flux vector. Precise knowledge of the rotor flux angle is therefore essential for a vector controlled IM. IMs do not allow the flux position to be easily measured, so most modern vector controlled IM drives rely on flux estimation. This means that the flux angle is derived from a flux estimator, using the dynamic model of the IM. Given that the rotor speed of the IM is measured by a mechanical shaft sensor. Flux estimation is a fairly easy task. However, vector control of IM without mechanical shaft speed sensor is of current interest in industrial environment. The driving motivations behind the development in sensorless control are lower cost, improved reliability and operating environment. In this thesis, a sensorless vector control scheme for rotor flux estimation using current error space phasor based hysteresis controller is proposed including the method for estimation of leakage inductance, Ls. For frequencies of operation less than 25 Hz, the rotor voltage and hence the rotor flux position is computed during the inverter zero voltage space vector using steady state model of IM. For above 25 Hz, active vector period and steady state model of IM is used. The whole rotor flux estimation scheme is dependent on current error space phasor and the steady state motor model, with rotor flux as a reference vector. Since no terminal voltage sensing is involved, dead time effects will not create problem in rotor flux sensing at low frequencies of operation. But appropriate device on-state drop are compensated at low frequencies (below 5 Hz) of operation to achieve a steady state operation up to less than 1 Hz. A constant switching frequency hysteresis current controller is used in inner current control loop for the PWM regulation, with smooth transition of operation to six-step mode operation. A simple Ls estimation based on current error space phasor is also proposed to nullify the deteriorating effect on rotor flux estimation. The parameter sensitivity of the control scheme to changes in the stator resistance Rs is also investigated. The drive scheme is tested up to a low frequency operation less than 1 Hz. The extensive simulation and experiment results are presented to show the proposed scheme’s good dynamic performance extending up to six-step operation. In contrast to vector control, direct torque control (DTC) method requires the knowledge of stator resistance only and thereby decreasing the associated sensitivity to parameters variation and the elimination of speed information. DTC as compared to vector control does not require co-ordinate transformation and PI controller. DTC is easy to implement because it needs only two hysteresis comparators and a lookup table for both flux and torque control. This thesis also investigates the possibilities in improvement of direct torque control scheme for high performance induction motor drive applications. Here, two schemes are proposed based on the direct torque control scheme for IM drive using 12-sided polygonal voltage space vectors for fast torque control. The torque control scheme based on DTC algorithm is proposed using 12-sided polygonal voltage space vector. The basic DTC scheme is used to control the torque. But the IM drive is open-end type. For torque control, the voltage space vectors orthogonal to stator flux vector in 12-sided polygonal space vector structure are used as hexagonal space vector based DTC scheme. The advantages achieved due to 12-sided polygonal space vector are mainly fast torque control and small torque ripple. The fast transient of torque with precise control is achieved using voltage space vector placed with a resolution of ±15. The torque ripple will be less as 6n±1 (n=odd) harmonic torque is totally eliminated from the whole range of PWM modulation. The comparative analysis of proposed 12-sided polygonal voltage space vector based DTC and conventional hexagonal space vector based DTC is also presented. Extensive simulation and experiment results are also presented to show the fast torque control at speeds of operation ranging from 5 Hz to the rated speed. The concept of 12-sided polygonal space vector based DTC is further extended for a variable speed control scheme using estimated fundamental stator voltage for sector identification. The conventional DTC scheme uses stator flux vector for identification of the sector and the switching vector are selected based on this sector information to control stator flux and torque. However, the proposed DTC scheme selects switching vectors based on the sector information of the estimated fundamental stator voltage vector and its relative position with respect to the stator flux vector. The fundamental stator voltage estimation is based on the steady state model of IM and information of synchronous frequency which is derived from computed stator flux using a low pass filter technique. The proposed DTC scheme utilizes the exact position of fundamental stator voltage vector and stator flux vector position to select optimal switching vector for fast control of torque with small variation of stator flux within hysteresis band. The present DTC scheme allows the full load torque control with fast transient response to very low speeds of operation below 5 Hz. The extensive simulation and experiment results are presented to show the fast torque control for speed of operation from zero speed to rated speed. However, the present scheme will have all the advantages of DTC scheme using stator flux vector for sector identification. All the above propositions are first simulated by MATLAB/Simulink and subsequently verified by an experimental laboratory prototype. The proposed control schemes are experimentally verified on a 3.7 kW IM drive. The control algorithms of the sensorless vector control using current error space phasor as well as DTC using 12-sided polygonal voltage space vector are completely implemented on a TI TMS320LF2812 DSP controller platform. These are some of the constituents for chapters 2, 3 and 4 in this thesis. Additionally, the first chapter also covers a brief survey on some of the recent progresses made in the field of sensorless vector control, direct torque control and current hysteresis controller. The thesis concludes with suggestion for further exploration.
5

Cálculo das sequências positiva e negativa em tempo real a partir do produto escalar de vetores espaciais: aplicações em compensadores de perturbações na rede. / Calculation of positive and negative sequences in real time by using space vectors dot products: applications to grid disturbances compensators.

Carvalho, Kelly Caroline Mingorancia de 02 February 2015 (has links)
O presente trabalho pretende aplicar o método de cálculo de componentes simétricas por produtos escalares de vetores espaciais para o cálculo dos sinais de referência de compensadores de perturbação. Outras metodologias de cálculo de corrente de referência são apresentadas, analisadas e comparadas com o método implementado. Uma revisão de vetores espaciais nos sistemas abc e 0 é feita para auxílio da explicação do método de extração de componentes simétricas. O método é inicialmente apresentado de forma generalista, de modo que é realizado o cálculo de componentes de sequência positiva, negativa e zero para um harmônico de ordem h. A autora apresenta algoritmos de exemplos práticos para uso em cálculo de corrente de referência incluindo as compensações de reativos da corrente fundamental, de harmônicos pré-selecionados e de desequilíbrios de carga. O método é analisado e validado por meio de simulações e resultados experimentais. / This work applies, for a disturbance compensator, a method for the calculation of the symmetrical components based on space vectors\' dot product. Other methods are presented, analyzed and compared with the proposed method. The symmetrical components calculation method is explained using a geometrical approach in abc and 0 basis. Initially, it is presented a general method that calculates the hth order positive, negative and zero sequence components of a current or voltage signal. Then, practical examples are presented for current compensation, which includes: fundamental reactive current compensation, fundamental negative sequence compensation and pre-selected order harmonics compensation. The method is analyzed and validated by simulation and experimental results.
6

Proširena teorija prostornih vektora za određivanje parametara ekvivalentne šeme asinhronih motora / Power electronic and electrical machines

Kiralj Ištvan 30 September 2016 (has links)
<p>Definisan je metod za određivanje prostornih vektora struje rotora asinhronih mašina sa kaveznim namotajem, kao i metod za proračun fazora fluksnih obuhvata i struja rotora i statora.<br />Uvedena je strujni fluksni obuhvat, koji pojednostavljulje postupak&nbsp; određivanja fazora fluksnih obuhvata.<br />Definisan je metod za proračun induktivnosti i otpornosti T ekvivalentne šeme asinhronih mašina.<br />Definisan je metod za proračun komponenata momenta, koje potiču od visokih prostornih harmonika struje, kao i pravilo za proračun rezultantnog momenta na osnovu harmoničkih komponenata momenta.</p> / <p>Method for determination of space vectors of currents in induction motors with squirrel cage, and a method for calculation phasors of flux linkages and currents of rotor and stator are determined.<br />Current-flux linkage is introduced, which simplifies determination of phasors of flux linkages.<br />Methods for calculation of inductances and resistances of T equivalent circuit for induction motors are defined.<br />A method for calculation of components of torque, which originate from high space harmonics of currents, and rules for calculation resultant torque on the basis of harmonic components of torque are determined.</p> / null
7

Investigation On Dodecagonal Multilevel Voltage Space Vector Structures By Cascading Flying Capacitor And Floating H-Bridge Cells For Medium Voltage IM Drives

Mathew, Jaison 07 1900 (has links) (PDF)
In high-power electric drives, multilevel inverters are generally deployed to address issues such as electromagnetic interference, switch voltage stress and harmonic distortion. The switching frequency of the inverter is always kept low, of the order of 1KHz or even less to reduce switching losses and synchronous pulse width modulation (PWM) is used to avoid the problem of sub-harmonics and beat frequencies. This is particularly important if the switching frequency is very low. The synchronous PWM is getting popularity as its realization is very easy with digital controllers compared to analog controllers. Neutral-point-clamped (NPC) inverters, cascaded H-bridge, and flying-capacitor multilevel inverters are some of the popular schemes used for high-power applications. Hybrids of these multilevel inverters have also been proposed recently to take advantage of the basic configurations. Multilevel inverters can also be realized by feeding the induction motor from both ends (open-end winding) using conventional inverter structures. For controlling the output voltage of these inverters, various PWM techniques are used. Chapter-1 of this thesis provides an over view of the various multilevel inverter schemes preceded by a discussion on basic two-level VSI topology. The inverters used in motor drive applications have to be operated in over-modulation range in order to extract the maximum fundamental output voltage that is possible from the dc-link. Operation in this high modulation range is required to meet temporary overloads or to have maximum power operation in the high speed range (flux weakened region). This, however, introduces a substantial amount of low order harmonics in the Motor phase voltages. Due to these low-order harmonic frequencies, the dynamic performance of the drive is lost and the current control schemes are severely affected especially due to 5th and 7th harmonic components. Further, due to these low-order harmonics and non-linear PWM operation in over-modulation region, frequent over-current fault conditions occur and reliability of the drive is jeopardized. The twelve sided-polygonal space vector diagram (dodecagonal space vectors) can be used to overcome the problem of low order 5th and 7th harmonics and to give more range for linear modulation while keeping the switching frequency at a minimum compared to conventional hexagonal space vector based inverters. Thus, the dodecagonal space-vector switching can be viewed as an engineering compromise between low switching frequency and quality load current waveform. Most of the previous works of dodecagonal space-vector generation schemes are based on NPC inverters. However, sophisticated charge control schemes are required in NPC inverters to deal with the neutral-point voltage fluctuation and the neutral-point voltage shifting issues. The losses in the clamping diodes are another major concern. In the second chapter, a multilevel dodecagonal space-vector generation scheme based on flying capacitor topology, utilizing an open end winding induction motor is presented. The neutral point charge-balancing problem reported in the previous works is not present in this scheme, the clamping diodes are eliminated and the number of power supplies required has been reduced. The capacitors have inherent charge balancing capability, and the charge control is done once in every switching cycle, which gives tight voltage control for the capacitors. For the speed control of induction motors, the space-vector PWM scheme is more advantageous than the sine-triangle PWM as it gives a more linear range of operation and improved harmonic performance. One major disadvantage with the conventional space-vector PWM is that the trigonometric operations demand formidable computational efforts and look-up tables. Carrier based, common-mode injected PWM schemes have been proposed to simplify the PWM process. However, the freedom of selecting the PWM switching sequences is limited here. Another way of obtaining SVPWM is using the reference voltage samples and the nearest vector information to switch appropriate devices for proper time intervals, realizing the reference vector in an average sense. In-formation regarding the sector and nearest vectors can be easily obtained by comparing the instantaneous amplitudes of the reference voltages. This PWM approach is pro-posed for the speed control of the motor in this thesis. The trigonometric operations and the requirement of large look-up tables in the conventional SVPWM are avoided in this method. It has the additional advantage that the switching sequences can be decided at will, which is helpful in reducing further, the harmonic distortion in certain frequency ranges. In this way, this method tries to combine the advantages of vector based methods (conventional SVPWM) and scalar methods (carrier-based methods). The open-end winding schemes allowed the required phase voltage levels to be generated quite easily by feeding from both ends of the windings. Thus, most of the multilevel inverters based on dodecagonal space-vector structures relied on induction motors with open-end windings. The main disadvantage of open-end winding induction motor is that six wires are to be run from the inverter to the motor, which may be unacceptable in certain applications. Apart from the inconvenience of laying six wires, the voltage reflections in the wires can lead to over voltages at the motor terminals, causing insulation failures. Where as the topology presented in chapter-2 of this thesis uses open-end winding motor with flying-capacitor inverters for the generation of dodecagonal space-vectors, the topology presented in chapter-3 utilizes a cascade connection of flying-capacitors and floating H-bridge cells to generate the same set of voltage space-vectors, thus allowing any standard induction motor as the load. Of the methods used for the speed control of induction motors, namely sine-triangle PWM and space vector PWM, the latter that provides extra modulation range is naturally preferred. It is a well-understood fact that the way in which the PWM switching sequences are applied has a significant influence on the harmonic performance of the drive. However, this topic has not been addressed properly for dodecagonal voltage space-vector based multilevel inverter drives. In chapter-4 of the thesis, this aspect is taken into ac-count and the notion of “harmonic flux trajectories” and “stator flux ripple” are used to analyze the harmonic performance of the various PWM switching schemes. Although the PWM method used in this study is similar to that in chapter-2, the modification in the PWM switching sequence in the PWM algorithm yields significant improvements in harmonic performance. The proposed topologies and PWM schemes are extensively simulated and experimentally verified. The control scheme was implemented using a DSP processor running at a clock frequency 150MHz and a four-pole, 3.7kW, 50Hz, 415V three-phase induction motor was used as the load. Since the PWM ports are limited in a DSP, a field-programmable gate array (FPGA) was used to decode the PWM signals from the DSP to generate timing information required for PWM sequencing for all the power devices. The same FPGA was used to generate the dead-time signals for the power devices also.
8

Multilevel Dodecagonal Space Vector Structures and Modulation Schemes with Hybrid Topologies for Variable Speed AC Drives

Kaarthik, R Sudharshan January 2015 (has links) (PDF)
MULTILEVEL inverters are the preferred choice of converters for electronic power conversion for high power applications. They are gaining popularity in variety of industrial applications including electric motor drives, transportation, energy management, transmission and distribution of power. A large portion of energy conversion systems comprises of multilevel inverter fed induction motor drives. The multilevel inverters are ideal for such applications, since the switching frequency of the devices can be kept low. In conventional two level inverters, to get nearly sinusoidal phase current waveform, the switching frequency of the inverter is increased and the harmonics in the currents are pushed higher in the frequency spectrum to reduce the size and cost of the filters. But higher switching frequency has its own drawbacks – in particular for medium voltage, high power applications. They cause large dv_/ dt stresses on the motor terminals and the switching devices, leading to increased electromagnetic interference (EMI) problems and higher switching losses. Harmonics in the motor currents can further be minimized by adopting dodecagonal voltage space vector (SV) switching (12-sided polygon). In case of dodecagonal SV switching, the fifth and seventh order (6n , 1, n = odd) harmonics are completely eliminated for the full modulation range including over modulation and twelve step operation in the motor phase voltages and currents. In addition to low order harmonic current suppression, the linear modulation range for dodecagonal SV switching is also more by 6% when compared to that of the conventional hexagonal SV switching. The dodecagonal voltage SV structure is made possible by connecting two inverters with DC-link voltages Vd and 0:366Vd on either side of an open-end winding induction motor. The dodecagonal space vector switching can be used to produce better quality phase voltage and current waveforms and overcome the problem of low order fifth and seventh harmonic currents and to improve the range for linear modulation while reducing the switching frequency of the inverters when compared to that of the conventional hexagonal space vector based inverters. This thesis focuses on three aspects of multilevel dodecagonal space vector structures (i) Two new power circuit topologies that generate a multilevel dodecagonal voltage space vector structure with symmetric triangles, (ii) A multilevel dodecagonal SV structure with nineteen concentric dodecagons, (iii) Pulse width modulation (PWM) timing calculation methods for a general N-level dodecagonal SV structure. (i) Two new power circuit topologies capable of generating multilevel dodecagonal voltage space vector structure with symmetric triangles with minimum number of DC link power supplies and floating capacitor H-bridges are proposed. The first power topology is composed of two hybrid cascaded five level inverters connected to either side of an open end winding induction machine. Each inverter consists of a three level neutral point clamped (NPC) inverter, cascaded with an isolated capacitor fed H-bridge making it a five level inverter. The second topology is a hybrid topology for a normal induction motor (star or delta connected), where the power is fed to the motor only from one side. The proposed scheme retains all the advantages of multilevel topologies as well the advantages of the dodecagonal voltage space vector structure. Both topologies have inherent capacitor balancing for floating H-bridges for all modulation indices including transient operations. The proposed topologies do not require any pre-charging circuitry for startup. PWM timing calculation method for space vector modulation is also explored in this chapter. Due to the symmetric arrangement of congruent triangles within the voltage space vector structure, the timing computation requires only the sampled reference values and does not require any iterative searching, off-line computation, look-up tables or angle estimation. Experimental results for steady state operation and transient operation are also presented to validate the proposed concept. (ii) A multilevel dodecagonal voltage space vector structure with nineteen concentric do-decagons is proposed for the first time. This space vector structure is achieved by connecting two sets of asymmetric hybrid five level inverters on either side of an open-end winding induction motor. The dodecagonal structure is made possible by proper selection of DC-link voltages and switching states of the inverters. In addition to that, a generic and simple method for calculation of PWM timings using only sampled reference values (v and v ) is proposed. This enables the scheme to be used for any closed loop application like vector control. Also, a new switching technique is proposed which ensures minimum switching while eliminating the fifth and seventh order harmonics and suppressing the eleventh and thirteenth harmonics, eliminating the need for bulky filters. The motor phase voltage is a 24-stepped waveform for the entire modulation range thereby reducing the number of switchings of the individual inverter modules. Experimental results for steady state operation, transient operation including start-up have been presented and the results of Fast Fourier Transform (FFT) analysis is also presented for validating the proposed concept. (iii) A method to obtain PWM timings for a general N-level dodecagonal voltage space vector structure using only sampled reference values is proposed. Typical methods that are used to find PWM timings for dodecagonal SV structures use modulation index and the reference vector angle, to get the timings T1 and T2 using trigonometric calculations. This method requires look-up tables and is difficult to implement in closed loop systems. The proposed method requires only two additions to compute these timings. For multilevel case, typical iterative methods need timing calculations (matrix multiplications) to be performed for each triangle. The proposed method is generic and can be extended to any number of levels with symmetric structures and does not require any iterative searching for locating the triangle in which the tip of the reference vector lies. The algorithm outputs the triangle number and the PWM timing values of T0, T1 and T2 which can be set as the compare values for any carrier based PWM module to obtain space vector PWM like switching sequences. Simulation and experimental results for steady state and transient conditions have been presented to validate the proposed method. A 3.7 kW, 415 V, 50 Hz, 4-pole open-end winding induction motor was used for the experimental studies. The semiconductor switches that were used to realize the power circuit for the experiment were 75 A, 1200 V insulated-gate bipolar transistor (IGBT) half-bridge modules (SKM75GB12T4). Opto-isolated gate drivers with desaturation protection (M57962L) were used to drive the IGBTs. For the speed control and PWM timing computation a digital signal processor (DSP-TMS320F28335) with a clock frequency of 150 MHz was used. For modulation frequencies 10 Hz and below, a constant sampling frequency of 1 kHz was used as the frequency modulation ratio is high. For modulation frequencies above 10 Hz, synchronous PWM strategy was used. The time duration Ts is the sampling interval for which the timings T1 , T2 and T0 are calculated. As in the case of any synchronous PWM method, the duration of sampling time (Ts) is a function of the fundamental frequency of the modulating signal. In this case, Ts = 1_.fm • 12n) sec. where fm is fundamental frequency in Hertz and ‘n’ is the number of samples per 30ý dodecagonal sector. The PWM timings and the triangle data (from the DSP) is fed to field programmable gate array (FPGA) (SPARTAN XC3S200) clocked at 50 MHz where the actual gating pulses are generated. The capacitor balancing algorithm and the dead-time modules were implemented within FPGA. No external hardware was used for generation of dead-time. The dead-time block generates a constant dead-time of 2 s for all the switches. Extensive testing was done for steady state operations and transient operations including quick acceleration and start-up to validate the proposed concepts. With the advantages like extension of linear modulation range, elimination of fifth and seventh harmonics in phase voltages and currents for the full modulation range, suppression of eleventh and thirteenth harmonics in phase voltages and currents, reduced device voltage ratings, lesser dv_dt stresses on devices and motor phase windings, lower switching frequency, inherent cascaded H-bridge (CHB) capacitor balancing, the proposed space vector structures, the inverter power circuit topologies, the switching techniques and the PWM timing calculation methods can be considered as viable schemes for medium voltage, high power motor drive applications.
9

Studies on Current Hysteresis Controllers and Low Order Harmonic Suppression Techniques for IM Drives with Dodecagoal Voltage Space Vectors

Azeez, Najath Abdul January 2013 (has links) (PDF)
Multilevel inverters are very popular for medium and high-voltage induction motor (IM) drive applications. They have superior performance compared to 2-level inverters such as reduced harmonic content in output voltage and current, lower common mode voltage and dv/dt, and lesser voltage stress on power switches. To get nearly sinusoidal current waveforms, the switching frequency of the conventional inverters have to be in¬creased. This will lead to higher switching losses and electromagnetic interference. The problem in using lower switching frequency is the introduction of low order harmonics in phase currents and undesirable torque ripple in the motor. The 5th and 7th harmonics are dominant for hexagonal voltage space-vector based low frequency switching. Dodecagonal voltage space-vector based multilevel inverters have been proposed as an improvement over the conventional hexagonal space vector based inverters. They achieve complete elimination of 5th and 7th order harmonics throughout the modulation range. The linear modulation range is also extended by about 6.6%, since the dodecagon is closer to circle than a hexagon. The previous works on dodecagonal voltage space vector based VSI fed drives used voltage controlled PWM (VC-PWM). Although these controllers are more popular, they have inferior dynamic performance when compared to current controlled PWM (CC¬PWM). VSIs using current controlled PWM have excellent dynamic response, inherent short-circuit protection and are simple to implement. The conventional CC-PWM tech¬niques have large switching frequency variation and large current ripple in steady-state. xix As a result, there has been significant research interest to achieve current controlled VSI fed IM drives with constant switching frequency. Two current error space vector (CESV) based hysteresis controllers for dodecagonal voltage space-vector based VSI fed induction motor drives are proposed in this work. The proposed controllers achieve nearly constant switching frequency at steady state operation, similar to VC-SVPWM based VSI fed IM drives. They also have fast dynamic response while at the same time achieving complete elimination of fifth and seventh order harmonics for the entire modulation range, due to dodecagonal voltage vector switching. The first work proposes a nearly constant switching frequency current error space vector (CESV) based hysteresis controller for an IM drive with single dodecagonal voltage space vectors. Parabolic boundaries computed offline are used in the proposed controller. An open-end winding induction motor is fed from two inverters with asymmetrical DC link voltages, to generate the dodecagonal voltage space vectors. The drive scheme is first studied at different frequencies with a space vector based PWM (SVPWM) control, to obtain the current error space vector boundaries. The CESV boundary at each frequency can be approximated with four parabolas. These parabolic boundaries are used in the proposed controller to limit the CESV trajectory. Due to symmetries in the parabolas only two set of parabola parameters, at different frequencies, need to be stored. A generalized next vector selection logic, valid for all sectors and rotation direction, is used in the proposed controller. For this an axis transformation is done in all sectors, to bring the CESV trajectory to the first sector. The sector information is obtained from the estimated fundamental stator phase voltage. The proposed controller is extensively studied using vector control at different frequencies and transient conditions. This controller maintains nearly constant switching frequency at steady state operation, similar to VC-SVPWM inverters, while at the same time achieving better dynamic performance and complete elimination of 5th and 7th order harmonics throughout the modulation range. In the second work the nearly constant switching frequency current hysteresis con¬troller is extended to multilevel dodecagonal voltage space-vector based IM drives, with online computation of CESV boundaries. The multilevel dodecagonal space-vector dia¬gram has different types of triangles, and the previously proposed methods for multilevel hexagonal VSI based current hysteresis controllers cannot be used directly. The CESV trajectory of the VC-SVPWM, obtained for present triangular region, is used as the reference trajectory of the proposed controller. The CESV reference boundaries are com¬puted online, using switching dwell time and voltage error vector of each applied vector. These quantities are calculated from estimated sampled reference phase voltages, which are found out from the stator current error ripple and the parameters of the induction motor. Whenever the actual current error space vector crosses the reference CESV tra¬jectory, an appropriate vector that will force it along the reference trajectory is switched. Extensive study of the proposed controller using vector control is done at different fre¬quencies and transient conditions. This controller has all the advantages of multilevel switching like low dv/dt, lesser electromagnetic interference, lower switch voltage stress and lesser harmonic distortion, in addition to all the dynamic performance advantages of the previous controller. The third work proposes an elegant 5th and 7th order harmonic suppression tech¬nique for open end winding split-phase induction motors, using capacitor fed inverters. Split-phase induction motors have been proposed to reduce the torque and flux ripples of conventional three-phase IM. But these motors have high 5th and 7th order harmonics in the stator windings due to lack of back-emf for these frequencies. A space-vector harmonic analysis of the split-phase IM is conducted and possible 5th and 7th order harmonic sup¬pression techniques studied. A simple harmonic suppression scheme is proposed, which requires the use of only capacitor fed inverters. A PWM scheme that can maintain the capacitor voltage as well as suppress the 5th and 7th order harmonics is also proposed. To test the performance of the proposed scheme, an open-loop v/f control is used on an open-end winding split-phase induction motor under no-load condition. Synchronized PWM with two samples per sector was used, for frequencies above 10 Hz. The har¬monic spectra of the phase voltages and currents were computed and compared with the traditional SVPWM scheme, to highlight the harmonic suppression. The concepts were initially simulated in Matlab/Simulink. Experimental verifica¬tion was done using laboratory prototypes at low power. While these concepts maybe easily extended to higher power levels by using suitably rated devices, the control tech¬niques presented shall still remain applicable. TMS320F2812 DSP platform was used to execute the control code for the proposed drive schemes. For the first work the output pins of the DSP was directly used to drive the inverter switches through a dead-band circuit. For the other two works, DSP outputs the sector information and the PWM signals. The PWM terminals and I/O lines of the DSP is used to output the timings and the triangle number respectively. An FPGA (XC3S200) was used to translate the sector information and the PWM signals to IGBT gate signal logic. A constant dead-time of 1.5 µs was also implemented inside the FPGA. Opto-isolated gate drivers with desaturation protection (M57962L) were used to drive the IGBTs. The phase currents and DC bus voltages were measured using hall-effect sensors. An incremental shaft position encoder was also connected to the motor to measure the angular velocity. The switches were realized using 1200 V, 75 A IGBT half bridge modules.
10

Investigations On Dodecagonal Space Vector Generation For Induction Motor Drives

Das, Anandarup 10 1900 (has links)
Multilevel converters are finding increased attention in industry and academia as the preferred choice of electronic power conversion for high power applications. They have a wide application area in a variety of industries involving transportation and energy management, a significant portion of which comprises of multilevel inverter fed induction motor drives. Multilevel inverters are ideally suitable for high power drives, since the switching frequency of the devices is limited for high power applications. In low power drives, the switching frequency is often in the range of tens of kHz, so that switching frequency harmonics are pushed higher in the frequency spectrum thereby the size and cost of the filter are reduced. But higher switching frequency has its own drawbacks, in particular for high voltage, high power applications. They cause large dv/dt stress on the motor and the devices, increased EMI problems and higher switching losses. An engineering trade-o is thus needed to select the minimum switching frequency without compromising on the output voltage quality. The present work is an alternate approach in this direction. Here, new inverter topologies and PWM strategies are developed that can eliminate a set of harmonics in the phase voltage using 12-sided polygonal space vector diagrams, also called dodecagonal space vector diagrams. A dodecagonal space vector diagram has many advantages over a hexagonal one. Switching space vectors on a dodecagon will not produce any harmonics of the order 6n 1, (n=odd) in the phase voltage. The next set of harmonics thus reside at 12n 1, (n=integer). By increasing the number of samples in a sector, it is also possible to suppress the lower order harmonics and a nearly sinusoidal voltage can be obtained. This is possible to achieve at a low switching frequency of the inverters. At the same time, a dodecagon is closer to a circle than a hexagon; so the linear modulation range is extended by about 6.6% compared to the hexagonal case. For a 50 Hz rated frequency operation, under constant V/f ratio, the linear modulation can be achieved upto a frequency of 48.3 Hz. Also, the harmonics of the order 6n 1, (n=odd) are absent in the over-modulation region. Maximum fundamental voltage is obtained from this inverter at the end of over-modulation region, where the phase voltage becomes a 12-step waveform. The present work is developed on dodecagonal space vector diagrams. The entire work can be summarized and explained through Fig. 1. This figure shows the development of hexagonal and dodecagonal space vector diagrams. It is known that, 3-level and 5-level space vector diagrams have been developed as an improvement over 2-level ones. They Figure 1: Development of hexagonal and dodecagonal space vector diagrams have better harmonic performance, reduced dv/dt stress on the motor and devices, better electromagnetic compatibility and improvement of efficiency over 2-level space vector diagrams. This happens because the instantaneous error between the reference vector and the switching vectors reduces, as the space vector density increases in the diagram. This is shown at the top of the figure. In the bottom part, the development of the dodecagonal space vector diagram is shown, which is the contribution of this thesis work. This is explained in brief in the following lines. Initially, a space vector diagram is proposed which switches on hexagonal space vectors in lower-modulation region and dodecagonal space vectors in the higher modulation region. As the reference vector length increases, voltage vectors at the vertices of the outer dodecagon and the vertices from the outer most hexagon is used for PWM control. This results in highly suppressed 5th and 7th order harmonics thereby improving the harmonic profile of the motor current. This leads to the 12-step operation at rated voltage where all the 5th and 7th order harmonics are completely eliminated. At the same time, the linear range of modulation extends upto 96.6% of base speed. Because of this, and the high degree of suppression of lower order harmonics, smooth acceleration of the motor upto rated speed is possible. The presence of multilevel space vector structure also limits the switching frequency of the inverters. In the next work, the single dodecagonal space vector diagram is improved upon to form two concentric dodecagons spanning the space vector plane (Fig. 1). The radius of the outer dodecagon is double the inner one. It reduces the device rating and the dv/dt stress on the devices to half compared to existing 12-sided schemes. The entire space vector diagram is divided into smaller sized isosceles triangles. PWM switching on these smaller triangles reduces the inverter switching frequency without compromising on the output voltage quality. The space vector diagram is further refined to accommodate six concentric dodecagons in the space vector plane (Fig. 1). Here the space vector diagram is characterized by alternately placed dodecagons which become closer to each other at higher radii. As such the harmonics in the phase voltage are reduced, in particular at higher modulation indices. At the same time, because of the dodecagonal space vector structure, all the 6n ± 1, (n=odd) harmonics are eliminated from the phase voltage. A nearly sinusoidal phase voltage can be generated without resorting to high frequency switching of the inverters. The above space vector diagrams are developed using different inverter circuits. The first work is developed from cascaded combination of three 2-level inverters, while the second and third works use 3-level NPC inverters feeding an open end induction motor drive. The circuit topologies are explained in detail in the respective chapters. Apart from this, PWM switching schemes and detailed analysis on duty cycle calculations using the concept of volt-second balance are also presented. They show that with proper switching schemes, the proposed configurations can substantially reduce the overall loss of the inverter. Other operational issues like capacitor voltage balancing of 3-level NPC inverters and improvement of input current drawn from the grid are also covered. All the above propositions are first simulated by MATLAB and subsequently verified by an experimental laboratory prototype. Motor current waveforms both at steady state and transient conditions during motor acceleration show that the induction motor can be fed from nearly sinusoidal voltage at all operating conditions. Simplified comparative studies are also made with the proposed converters and higher level inverters in terms of output voltage quality and losses. These are some of the constituents for chapters 2, 3 and 4 in this thesis. Additionally, the first chapter also covers a brief survey on some of the recent progresses made in the field of multilevel inverter. The thesis concludes with some interesting ideas for further thought and exploration.

Page generated in 0.0874 seconds