111

[en] METROLOGICAL EVALUATION OF ZINC OXIDE VARISTORS OF MEDIUM VOLTAGE / [pt] AVALIAÇÃO METROLÓGICA DE VARISTORES DE ÓXIDO DE ZINCO PARA MÉDIA TENSÃO

FERNANDO ANTONIO TUPINAMBA BARBOSA 24 June 2005 (has links)
[pt] Apesar de seus muitos benefícios, uma das poucas desvantagens da tecnologia do semicondutor é a vulnerabilidade dos dispositivos de estado sólido à temperatura, sobretensões e sobre correntes. Mesmo os pulsos de tensão de energia muito baixos, podem produzir interferências e danos, às vezes com conseqüências de grande envergadura. Assim, enquanto a eletrônica é utilizada em mais e mais aplicações, a temperatura, a proteção contra sobretensão e a supressão de transientes transformam-se em fatores de suma importância para o desenvolvimento de um projeto. Os varistores provaram ser excelentes dispositivos protetores por causa da sua flexibilidade da aplicação e elevada confiabilidade. Os varistores do óxido do zinco (ZnO) são dispositivos eletrônicos de última geração, desenvolvidos para promover a proteção de circuitos elétricos contra a sobretensão, causada pelas descargas elétricas atmosféricas, tensões induzidas e manobras elétricas, e ideal para limitar a corrente de pico, bem como para absorver energia. O objetivo deste trabalho é propor uma metodologia para avaliação metrológica de varistores de óxido de zinco de média tensão, visando garantir o atendimento dos requisitos metrológicos para a proteção de circuitos elétricos, eletrônicos e de telecomunicações contra a sobretensão e supressão de transientes elétricos. Propõe-se ainda determinar a incerteza de medição dos parâmetros temperatura, tensão, corrente e resistência ôhmica de amostras comerciais de varistores de óxido de zinco. / [en] Despite its many benefits, one of the few disadvantages of semiconductor technology is the vulnerability of solid state devices to undesired increase in temperature, voltage and current . Even low voltage pulses can produce interference and damages with several consequences. Thus, as electronics are used in more and more applications, temperature, protection against surge and transient suppression are becoming factors of decisive importance in projects. Varistors have proven to be excellent protective devices due to their flexibility in applications and heightened trustworthiness. The zinc oxide varistors (ZnO) are state of the art electronic devices of last generation, developed to promote the protection of electric circuits against overvoltage, caused by atmospheric electric discharges, induced voltages and electric maneuvers, and suited to limit peak current, as well as absorbing energy. The purpose of this work is to propose a methodology for experimental characterization of zinc oxide varistors of average voltage, with the purpose of guarantee the attendance of the metrological requirements for protection of electric, electronic and telecommunication circuits against transient surges and suppression of electric transients. Uncertainty of measurement of the parameters temperature, voltage, current and ohmic resistance on commercial samples of zinc oxide varistors are also determined.
112

[pt] REOLOGIA DE OLEOS PARAFINICOS CRUS / [en] RHEOLOGY OF WAXY CRUDE OILS

10 November 2021 (has links)
[pt] Esta tese é sobre a reologia de óleos parafínicos crus. Um protocolo baseado na literatura relevante é desenvolvido para garantir que históricos térmico e de cisalhamento bem definidos sejam impostos em amostras que serão submetidas à medições reológicas. Com este protocolo, uma caracterização reológica quase completa de um óleo parafínico cru brasileiro é executada . Quatro experimentos reométricos são realizados, a saber, escoamento em estado estacionário, taxa de cisalhamento constante, tensão constante e rampa oscilatória de amplitude de tensão. Propriedades reológicas importantes, tais como, viscosidade, tensão limite de escoamento e módulos elástico e viscoso são medidos com o auxílio de técnicas diferentes em uma ampla faixa de condições. Além disso, uma comparação entre essas técnicas de medição é realizada. O processo de quebra da microestrutura do óleo parafínico brasileiro, assim como os efeitos na reologia do histórico do material e do tempo de repouso isotérmico são estudados. Fenômenos interessantes são observados, incluindo bifurcação da taxa de cisalhamento, dependência da tensão limite com os históricos térmico e de cisalhamento e independência dos resultados de regime permanente com relação à condição inicial após o resfriamento. Por fim, oportunidades para futuros desenvolvimentos e investigações são enfatizadas. / [en] This thesis deals with the rheology of waxy crude oils. A protocol based on the relevant literature is developed to guarantee well defined shear and thermal histories to waxy crude oil samples to be submitted to rheological measurements. With this protocol, a fair complete rheological characterization of a Brazilian waxy crude oil is performed. Four rheometric experiments, namely steady-state flow, constant shear rate, constant shear stress, and dynamic-stress-amplitude sweep are carried out. Important rheological properties, such as, viscosity, yield stress, and storage and loss moduli are measured with di↵erent techniques in a wide range of conditions and a comparison between the techniques is presented. The yielding as well as the history effects and the e↵ects of isothermal holding time on the microstructure and rheology of a Brazilian waxy crude oil are investigated. Interesting phenomena are observed, including bifurcation of shear rate, dependence of the yield stress with thermal and shear histories, and independence of the steady-state results with the post-cooling initial condition of the experiment. At last, opportunities for further developments are highlighted.
113

[en] LOCALLY STRESS-CONSTRAINED TOPOLOGY OPTIMIZATION WITH CONTINUOUSLY VARYING LOADING DIRECTION AND AMPLITUDE: TOWARD LARGE-SCALE PROBLEMS / [pt] OTIMIZAÇÃO TOPOLÓGICA COM RESTRIÇÕES LOCAIS DE TENSÃO E VARIAÇÃO CONTÍNUA DA DIREÇÃO E AMPLITUDE DO CARREGAMENTO: APLICAÇÕES EM PROBLEMAS DE GRANDE ESCALA

FERNANDO VASCONCELOS DA SENHORA 21 June 2022 (has links)
[pt] Otimização topológica (OT) é uma técnica de otimização estrutural capaz de gerar projetos incrivelmente detalhados para uma grande gama de problemas. No entanto, a maioria dos trabalhos de OT presentes na literatura está focada em problemas de minimização de flexibilidade, que não consideram a resistência dos materiais durante o processo de otimização, levando a soluções que não satisfazem limites de falha do material. Neste trabalho, focamos em problemas de OT baseados em tensão no qual introduzimos restrições de tensão no problema de otimização, para garantir a integridade estrutural do projeto final. A formulação de tensão de OT nos leva a um problema de engenharia muito mais natural que nos remete à seguinte pergunta: Qual a estrutura mais leve capaz de suportar as cargas as quais será submetida? Para ajudar a responder essa pergunta e para trazer a OT para mais próximo de aplicações reais, neste trabalho foi desenvolvido um sistema computacional em paralelo, baseado em GPU, considerando uma carga que pode variar a sua direção continuamente e capaz de resolver problemas de larga escala. A implementação em GPU apresenta soluções eficientes para os principais problemas de OT de larga escala, como o filtro, o algoritmo de otimização e a solução das equações de equilíbrio. Ao mesmo tempo, ao considerar uma carga variando continuamente que mais se aproxima das condições reais de carregamento usando uma estratégia de pior cenário, obtém-se soluções mais robustas e mais adequadas a aplicações de engenharia. Várias soluções numéricas são apresentadas, incluindo problemas 3D com mais de 45 milhões de restrições de tensão, que demonstram a efetividade das técnicas desenvolvidas neste trabalho. O sistema de larga escala baseado em GPU combinado com as soluções analíticas para a variação contínua de carga, tem o potencial de expandir o uso da OT na engenharia levando a novas e mais eficientes estruturas. / [en] In the field of structural optimization, Topology Optimization (TO) is one of the most general techniques because it is able to generate complex structures with intricate details for a wide range of problems. However, most of the works in TO have focused on compliance-based design that does not consider material strength in the design process leading to structures that do not satisfy material failure requirements. In this work, we focus on the stress-based design approach. We introduce stress constraints in the optimization procedure to guarantee the structural integrity of the final optimized design. This leads to a more natural formulation that addresses a simple engineering question: What is the lightest structure able to withstand its loads? We developed a large-scale GPU-based parallel stress-constrained TO framework considering a continuous range of varying load directions to answer this question and close the gap between TO and practical application. The developed GPU-based C++/CUDA framework efficiently addresses the main challenges of large-scale TO, filtering, optimization algorithm, and the solution of the equilibrium equations, only requiring a moderately affordable GPU hardware. At the same time, we obtain designs that are more suitable for engineering applications by considering a continuous variable range of load directions that more closely resemble real-life service loads using a worstcase analytical approach. We present several numerical results, including 3D problems with over 45 million local constraints providing detailed optimal structures that demonstrate the capabilities of the techniques developed in this work. The large-scale GPU framework, combined with the analytical solutions for continuously varying load cases, has the potential to expand the applications of TO techniques leading to improved engineering designs.
114

[en] METHODS BASED ON SYNCHRONIZED PHASOR MEASUREMENTS FOR VOLTAGE STABILITY MONITORING / [pt] MÉTODOS BASEADOS EM MEDIÇÕES FASORIAIS SINCRONIZADAS PARA O MONITORAMENTO DA ESTABILIDADE DE TENSÃO

DIOGO CARDOSO LIMA 03 December 2020 (has links)
[pt] O fenômeno associado à estabilidade de tensão se caracteriza pela existência de valores máximos de potência ativa e reativa que podem ser transferidas a uma barra de carga, ou injetada na rede através dos geradores e compensadores síncronos. Sua relevância para o setor elétrico é constantemente reforçada pelo registro de ocorrências de colapsos de tensão em diversos países do mundo e, embora a instabilidade de tensão manifeste-se localmente, suas consequências se refletem na ampla deterioração do sistema. Impulsionado pelo crescente interesse a respeito dos métodos baseados em medições fasoriais sincronizadas para a detecção do máximo carregamento, este trabalho apresenta os principais modelos encontrados na literatura baseados em medições locais e no vasto monitoramento do sistema, com maior ênfase aos métodos de Corsi-Taranto e Circuito Acoplado de Porta-Simples Aprimorado (CAPS Aprimorado). Algumas contribuições são sugeridas ao modelo CAPS Aprimorado tendo em vista sua aplicação ao conjunto de barras de transferência e de geração. Explora-se a utilização dos equivalentes multi-portas como índice de avaliação das condições de estabilidade de tensão, comparando a identificação da barra crítica aos métodos da matriz D e dos autovalores e autovetores. São evidenciadas as principais limitações dos modelos mediante a um conjunto de análises estáticas e dinâmicas, considerando diferentes cenários de carregamento, a sensibilidade dos modelos ao ruído e a resposta dos métodos em face da atuação dos limitadores de sobre-excitação. / [en] The voltage stability phenomenon is characterized by the existence of a maximum active and reactive power that can be transferred to a load bus or injected into the network through the generators and synchronous compensators. Its relevance to the electric power sector is constantly reinforced by the record of occurrences of voltage collapses in several countries around the world. Although the voltage instability manifests itself locally, its consequences is reflected in the wide deterioration of the system. Driven by growing interest in methods based on synchronized phasor measurements for maximum loadability detection, this work presents the main models found in the literature based on local measurements and wide area monitoring, emphasizing the Corsi-Taranto method and Improved Coupled Single-Port Circuit (Improved CAPS). Some contributions are suggested to the Improved CAPS model considering its application to the set of transit and controlled buses. The use of the multi-port equivalents is explored as the evaluation index of voltage stability conditions, comparing the identification of the critical bus to the D matrix method and eigenvalues and eigenvalues method. The main limitations of the models are demonstrated through a static and dynamic studies, as well different loading scenarios, the sensitivity of the models to the noise and the response of the methods when the over-excitation limiters are considered.
115

[es] ESTUDIO EXPERIMENTAL DEL RELAJAMIENTO DE UNA FIBRA SINTÉTICA DE ALTA RESISTENCIA / [pt] ESTUDO EXPERIMENTAL DA RELAXAÇÃO DE UMA FIBRA SINTÉTICA DE ALTA RESISTÊNCIA / [en] EXPERIMENTAL INVESTIGATION ON THE STRESS RELAXATION BEHAVIOR OF A HIGH-STRENGTH ARAMID FIBER

MARGARETH DA SILVA MAGALHAES 19 February 2001 (has links)
[pt] Neste trabalho é feito um estudo experimental da relaxação de uma fibra sintética de alta resistência, conhecida como Kevlar 49, empregada na fabricação de cabos que podem ser usados como cabos de protensão. O objetivo é obter uma equação para o cálculo da relaxação e verificar a influência de um condicionamento mecânico (aplicação e remoção de uma tensão). Foram realizados ensaios em seis amostras da fibra sob cinco níveis de tensão, equivalentes a 10%, 20%, 30%, 40% e 50% da tensão de ruptura do material. Os ensaios foram realizados com a temperatura e umidade relativa do ar controlados na faixa de 21oC + 2oC e 77% + 7% respectivamente. O tempo de duração de cada ensaio foi de 72 horas. Os resultados revelaram que as curvas de relaxação são lineares quando plotadas numa escala logarítmica do tempo e que o coeficiente de relaxação é bem representado por uma função potencial e depende da tensão aplicada. Em adição revelaram que um condicionamento mecânico não altera o comportamento da fibra. / [en] High-strength aramid fibers have been used in the production of a variety of cables and ropes which have found several applications as structural members in bridges and other types of structures. For such applications, a sound knowledge of the time dependent material properties is highly important. An experimental investigation on the stress relaxation behavior of a high-strength aramid fiber was carried out, with the purpose of studying the viscoelastic properties of the material and the effect of a mechanical conditioning (application and removal of stress prior to testing) on these properties. The fiber used in this investigation is commercially known as Kevlar 49. The tests were conducted at five different stress levels, at constant temperature and moisture. The results showed that the fiber has a non-linear viscoelastic behavior and that the effect of the mechanical conditioning isn´t important. An equation for the prediction of the stress relaxation is presented. / [es] En este trabajo se realiza un estudio experimental de la relajamiento de una fibra sintética de alta resistencia, conocida como Kevlar 49, empleada en la fabricación de cables que pueden ser usados como cables de protensión. El objetivo es obtener una ecuación para el cálculo dela relajamiento y verificar la influencia de un condicionamento mecánico. Fueron realizados ensayos en seis muestras de la fibra bajo cinco niveles de tensión, equivalentes a 10%, 20%, 30%, 40% y 50% de la tensión de ruptura del material. Los ensayos fueron realizados con la temperatura y la humedad relativa del aire controlados en la faja de 21oC + 2oC y 77% + 7% respectivamente. El tiempo de duración de cada ensayo fue de 72 horas. Los resultados revelaron que las curvas de relajamiento son lineales cuando se utiliza una escala logarítmica para el tiempo y que el coeficiente de relajamiento está bien representado por una función potencial, que depende de la tensión aplicada. Adicionalmente, los ensayos revelaron que un condicionamento mecánico no altera el comportamiento de la fibra.
116

[en] A LOAD MODELING METHODOLOGY FOR STEADY STATE AND DYNAMIC SIMULATIONS / [pt] UMA METODOLOGIA DE MODELAGEM DE CARGAS PARA SIMULAÇÕES EM REGIME PERMANENTE E DINÂMICAS

IGOR FERREIRA VISCONTI 21 May 2020 (has links)
[pt] Para simular, prever e controlar os sistemas de energia elétrica, engenheiros precisam de ferramentas computacionais para modelar os componentes dessa rede interconectada altamente complexa. Muitos esforços ao longo do século passado foram dedicados a desenvolver modelos matemáticos para geradores, linhas de transmissão, compensadores de potência reativa, transformadores e assim por diante. Os principais componentes dos sistemas de potência são representados precisamente através de modelos matemáticos, mas as cargas ainda são uma fonte de incerteza nas simulações, devido à sua característica de aleatoriedade. Modelos de carga conservadores superestimam a resposta de potência a desvios de tensão, enquanto modelos de carga excessivamente otimistas podem subestimar as margens de estabilidade, deixando o sistema muito próximo do seu limite operacional. É preciso estabelecer representações de cargas tão próximas da realidade quanto possível, a fim de explorar os recursos de rede de modo mais eficiente. Este trabalho fornece uma metodologia para modelagem de carga, investigando e resumindo as etapas do processo, que podem ser implementadas de diversas maneiras. O tratamento de dados, a escolha de uma representação matemática do modelo de carga e sua estimação de parâmetros são apresentados através de estudos de caso reais, tanto para uma aplicação focada na dinâmica do sistema elétrica, quanto para uma aplicação em regime permanente. Discute-se como otimização e conceitos de inferência estatística podem ser ferramentas efetivas para alcançar melhores aproximações sobre como a carga responderá a perturbações causadas por variações de tensão, sejam estas variações espontâneas, ou devido a ações de controle, ou causadas por curtos-circuitos. / [en] To simulate, predict and control Electric Power Systems (EPS), engineers need tools to model the components of this highly complex interconnected network. Many efforts over the past century were dedicated to develop mathematical models for generators, transmission lines, reactive power compensators, transformers and so on. The main components of the power systems are precisely represented by mathematical models, but the loads are still a source of uncertainty in the simulations, due to their random characteristics. It is well known that conservative load models super estimate power response to voltage deviations, and, on the other hand, over-optimistic load models may underestimate stability margins, leading a system to operate too close to its limit. It is necessary to stablish load representations as close to reality as possible, in order to fully exploit grid resources. This work provides a methodology for load modeling, investigating and summarizing the steps of the process, whose can be implemented in a wide variety of ways. Data treatment, the choice of a load model representation and their parameters estimation are presented through real case studies, both for dynamic simulation and a steady state application. It is discussed how optimization and statistical inference concepts can be effective tools to reach better approximations on how load will respond to disturbances caused by voltage variations, whether these were spontaneous, due to control actions, or caused by short-circuits.
117

[en] DESIGN AND DEVELOPMENT OF MEASUREMENT SYSTEM FOR IMPULSE VOLTAGE PUNCTURE TESTING ON INSULATORS / [pt] PROJETO E DESENVOLVIMENTO DE SISTEMA DE MEDIÇÃO PARA ENSAIOS DE IMPULSO DE PERFURAÇÃO EM ISOLADORES

IGHOR SOUZA DOS SANTOS 30 April 2020 (has links)
[pt] O ensaio de impulso para perfuração de isoladores é um ensaio normalizado descrito na IEC 61211:2004 e é fundamental para verificar em laboratório a qualidade de isoladores de vidro ou porcelana utilizados no sistema elétrico de potência. A norma IEC 60060-2:2010 recomenda que a calibração dos Sistemas de Medição utilizados em ensaios para Perfuração de Isoladores (SMIP) deve ser realizada por comparação com um padrão. Contudo, embora o ensaio de perfuração seja normalizado, ainda não existem padrões para rastrear esse sistema de medição na maioria dos institutos de pesquisas em âmbito global. Quantificar a amplitude de um impulso de perfuração, com todas as garantias metrológicas, não é uma tarefa trivial, por se tratar de um sinal impulsivo com amplitude de centenas de kilovolts e durações da ordem de 200 ns. Além disso, divisores de tensão com alto desempenho dinâmico para essa aplicação especifica também não estão disponíveis comercialmente. Deste modo, o objetivo desta dissertação foi projetar e desenvolver um SMIP. O divisor de tensão, integrante do sistema de medição, foi construído a fim de garantir uma mínima indutância e um alto desempenho dinâmico. Também foi desenvolvido um filtro para a remoção de interferências eletromagnéticas baseado na transformada wavelet, integrado a um software que controla aquisição, condicionamento do sinal, determinação e análise dos parâmetros do impulso de perfuração. O desempenho do sistema de medição foi avaliado em baixa tensão e em alta tensão, bem como foi estimada sua incerteza de medição, sendo então capaz de atender às exigências normativas e metrológicas do Laboratório de Referência em medição do Cepel. / [en] Impulse testing for puncture insulator is a standardized test described in IEC 61211:2004 and is essential for laboratory testing of the quality of glass or porcelain insulators used in the electrical power system. IEC 60060-2:2010 recommends that calibration of Measurement Systems used in Impulse Puncture Test on insulators (IPMS) should be performed by comparison against a standard. However, although the impulse puncture testing is standardized, there are still no standards for traceability of this measurement system at most research institutes globally. Quantifying the amplitude of an impulse puncture test, with all metrological guarantees, is not a trivial task, since it is an impulsive signal with amplitude of hundreds of kilovolts and durations of the order of 200 ns. In addition, high dynamic performance voltage dividers for this specific application are not commercially available either. Thus, the objective of this dissertation was to design and develop an IPMS. The voltage divider, which is part of the measuring system, is designed to ensure minimum inductance and high dynamic performance. A filter for electromagnetic interference removal based on the wavelet transform was also developed, integrated with software that controls acquisition, signal conditioning, determination and analysis of the impulse puncture testing parameters. The performance of the measuring system was evaluated at low voltage and high voltage, as well as its measurement uncertainty was estimated, being able to meet the normative and metrological requirements of the Cepel s Measurement Reference Laboratory.
118

[en] THE ESCHATOLOGICAL NATURE OF THE CHURCH: THE ALREADY AND NOT YET THE FULLNESS OF OUR SALVATION, A REFLECTION FROM THE SEVENTH CHAPTER OF LUMEN GENTIUM / [pt] A ÍNDOLE ESCATOLÓGICA DA IGREJA: UM ESTUDO DO JÁ E DO AINDA NÃO À LUZ DO SÉTIMO CAPÍTULO DA LUMEN GENTIUM

FANTICO NONATO SILVA BORGES 14 March 2019 (has links)
[pt] A índole escatológica da Igreja, como reflexão teológica, é muito pertinente, visto que trata da relação entre a estrutura visível da Igreja e aquela realidade pensada como meta última da atividade eclesial. A escatologia do Vaticano II trouxe à tona essa reflexão, quando salientou que a tensão escatológica entre o já e o ainda não faz parte da natureza do Novo Povo de Deus, e que, por isso mesmo, a Igreja é sinal e instrumento desta plenitude da esperança no meio da humanidade. Sendo um sinal, ela se torna, para o mundo, sacramento visível da unidade de gênero humano, com Deus e consigo mesma. Nossa pesquisa deseja enfocar a posição do Concílio Vaticano II acerca dessa situação-missão da Igreja, pois, para os Padres conciliares, a salvação prometida pelo Senhor já começou em Cristo, mas ainda não se consumou, porque o tempo da restauração de todas as coisas dar-se-á somente quando tudo estiver no Pai pelo Filho no Espírito. Então, neste instante, o homem e com ele toda a criação chegará à sua restauração final. Enquanto isso não acontecer, a Igreja é impelida a levar adiante a obra de santificação da humanidade, como missão imputada por Cristo na unidade do Espírito Santo. Esse trabalho quer, portanto, demonstrar como essa salvação de Cristo continua por meio da ação eclesial, que instrui seus filhos sobre o sentido da vida temporal, enquanto esperança dos bens futuros e compromisso com o Reino de Deus. / [en] The eschatological nature of the Church as theological reflection, it is very relevant, since it is the relationship between the visible structure of the Church and that dream reality as the ultimate goal of ecclesial activity. The eschatological nature of Vatican II brought up this discussion when he emphasized that the eschatological tension between the already and not yet is in the nature of the new people of God, and that, therefore, the Church is sign and instrument of fullness of Hope in the midst of humanity. As a sign, it becomes the world visible sacrament of the unity of mankind with God and with herself. Our research focuses on the position of Vatican II about the situation, the Church s mission, as for the Fathers, the salvation promised by the Lord already begun in Christ, but not yet consummated, because the time of the restoration of all things give will be only when all; the man and with him the whole creation reach its final restoration in Christ. In the meantime the church is compelled to carry on the work of sanctification of humanity as mission charged by Christ in the unity of the Holy Spirit. This work therefore want to show how the salvation of Christ continues through the action of the Church, instructing their children about the meaning of temporal life, as hope of eternal life and commitment to the Kingdom of God.
119

[en] LINEAR ELASTIC FRACTURE MECHANICS ANALYSIS OF FATIGUE CRACK GROWTH UNDER COMPLEX LOADING USING THE DIGITAL IMAGE CORRELATION TECHNIQUE / [pt] ANÁLISE DO CRESCIMENTO DE TRINCAS DE FADIGA PELA MECÂNICA DE FRATURA ELASTICA LINEAR SOB CARGA COMPLEXA UTILIZANDO A TÉCNICA DE CORRELAÇÃO DE IMAGENS DIGITAIS

JORGE GUILLERMO DIAZ RODRIGUEZ 25 January 2019 (has links)
[pt] A avaliação da propagação de trincas de fadiga inclui a identificação da direção da trinca, o conhecimento do Fator de Intensidade de Tensões (SIF) equivalente, a determinação de uma taxa de crescimento de comprimento de trinca por número de ciclos da/dN e o estabelecimento de uma regra de propagação de trinca conectando SIF e da/dN, como uma regra de tipo Paris. Quando ocorrem cargas mistas e não proporcionais, esses parâmetros ainda não são totalmente compreendidos. Esta tese trata de algumas das variáveis que influenciam a propagação de trincas sob carregamento no modo misto não proporcional. A técnica de Correlação de Imagens Digitais (DIC) foi utilizada para a aquisição de imagens de corpos de prova submetidos a carregamento proporcional e não proporcional cíclico. Dois tipos de corpos de prova foram utilizados. Primeiramente, dois corpos de prova planos foram testados; um disk compact tension (DCT, em inglês) e um compact tension modificado (C (T) em inglês). Eles foram submetidos a carregamento cíclico induzindo o modo I de abertura de trinca ou modos I e II de abertura de trinca proporcionais. Em segundo lugar, os dados DIC adquiridos anteriormente, e em outro lugar, para cinco tubos finos sujeitos a carregamento cíclico foram analisados. Os tubos finos tiveram entalhes usinados a partir dos quais as trincas por fadiga iniciaram e se propagaram. Esses cinco tubos finos foram submetidos a diferentes casos de carga proporcional e não proporcional. Um corpo de prova tipo tubo fino foi exposto a carga axial e apresentou modo de abertura de trinca tipo I. Os outros quatro foram submetidos a carregamento de torção ou carga axial-torcional mista e exibiram todos os três modos de abertura de trinca I, II e III. Os campos de deslocamento adquiridos experimentalmente com a técnica DIC foram processados para calcular independentemente o SIF para cada modo de abertura existente usando formulações de mecânica de fratura elástica linear (MFLE). Uma formulação delas utilizou dados de deslocamento de campo completos adquiridos em pequenas áreas que circundavam a ponta da trinca. Outra formulação usou dados adquiridos de um par de pontos localizados ao longo dos flancos opostos das faces da trinca. Os SIFs determinados foram usados para encontrar os SIFs equivalentes e faixas de SIF equivalentes usando o critério da tensão máxima de tração (para ambas as versões 2D e 3D de combinações dos modos I-II e modos I-II-III respectivamente) que implicitamente incluíram o ângulo de propagação de trinca. Verificou-se que a inclusão do SIF no modo III experimentalmente determinado efetivamente faz diferença nas faixas do SIF e dos SIF equivalentes estimados. A curva da/dN versus faixa do SIF equivalente foi elaborado com as taxas de crescimento de trinca medidas experimentalmente e as faixas de SIF que foram encontradas usando a suposição amplamente aceita de que as trincas cresceram na direção que maximiza a tensão de tração. Para isso, extensões do modelo de Schollmann et. al. e bem como o modelo de Erdogan-Sih, que são geralmente aplicados ao carregamento proporcional, foram usados para determinar os SIFs equivalentes e faixas de SIF equivalentes para os casos de carregamento proporcional e não proporcional. Finalmente, a segunda zona da regra de Paris (da/dN versus faixa do SIF equivalente) foi plotada para os cinco casos de carregamento nos tubos finos mostrando que eles caíram dentro de uma faixa razoavelmente fina e dispersa. / [en] Fatigue crack propagation assessment includes identifying the crack direction, knowing the equivalent Stress Intensity Factor (SIF) range, determining a crack length growth rate per number of cycles (da/dN), and establishing a crack propagation rule connecting the equivalent SIF and da/dN rate, such as a Paris type of rule. When mixed and non-proportional loading occur, those parameters are not fully understood yet. This thesis deals with some of the variables that influence crack propagation under non-proportional mixed mode loading. The Digital Image Correlation (DIC) technique was used to acquire images of test specimens subjected to cyclic proportional and non-proportional loading. Two types of specimen samples were used. Firstly, two different plate test specimens were tested; a disk compact tension (DCT), and a modified compact tension, C(T). They were subjected cyclic loading inducing crack opening mode I or proportional crack opening modes I and II. Secondly, the previously and elsewhere acquired DIC data for five thin tubes subject to cyclic loading were analyzed. The thin tubes had pre-fabricated slit-notches from which fatigue cracks initiated and propagated. Those five thin tubes were subjected to different cases of proportional and non- proportional loading. One tube specimen was exposed to axial loading and presented mode I crack opening. The other four were subjected to torsion loading or mixed axial-torsional loading and exhibited all three I, II and III crack-opening modes. The experimentally acquired DIC displacement fields were processed to independently calculate SIF for each existing opening mode using linear elastic fracture mechanics (LEFM) formulations. One formulation used full field displacement data acquired in small areas that surrounded the crack tip. Another formulation used data acquired from a pair of points located along the opposite crack flanks. The determined SIFs were used to find equivalent SIFs and equivalent SIF ranges using the maximum tensile stress criterion (for both 2D and 3D versions of combinations of modes I-II and modes I-II-III respectively) which implicitly included the crack propagation angle. It was found that the inclusion of the experimentally determined mode III SIF indeed makes a difference in the determined equivalent SIF and equivalent SIF ranges. A da/dN versus equivalent SIF ranges plot was drafted with the experimentally measured crack growth rates and the SIF ranges that were found by using the widely accepted assumption that the cracks grew in the direction that maximizes the tensile stress. For this, extensions of the Schollmann et. al. model as well as of the Erdogan-Sih model, which are generally applied to proportional loading, were used to determine equivalent SIFs and equivalent SIF ranges for the cases of proportional and non-proportional loading. Finally, the second stage of the Paris rule (da/dN versus SIF range) was plotted for the five thin tubes loading cases showing that they fell inside a reasonably thin scattered band.
120

[pt] CONTROLE DO INVERSOR DE UMA USINA FOTOVOLTAICA PARA MELHORA DA ESTABILIDADE TRANSITÓRIA DE UMA MÁQUINA SÍNCRONA / [en] PROPOSED INVERTER CONTROL OF A PHOTOVOLTAIC GENERATION UNIT FOR THE IMPROVEMENT OF THE TRANSIENT STABILITY OF A SYNCHRONOUS MACHINE

OSCAR CUARESMA ZEVALLOS 08 April 2021 (has links)
[pt] O incremento de geração fotovoltaica de grande porte traz consideráveis mudanças nas características operativas e dinâmicas do sistema quando este é submetido a grandes distúrbios. Um dos problemas técnicos mais relevantes é a estabilidade transitória, já que a geração intermitente ligada ao sistema por conversores eletrônicos não contribui para o aumento da inércia total do sistema. Entretanto, os conversores eletrônicos podem, potencialmente, trazer novas oportunidades de controle rápido para dar suporte aos geradores síncronos em resposta a um distúrbio severo. No presente trabalho propõe uma estratégia de controle para inversores fotovoltaicos baseado na injeção da corrente com um grande impacto na resposta transitória do ângulo do rotor da máquina síncrona, identificada através da análise de sensibilidade dos autovalores e dos fatores de participação. Ao fazer isso, é possível aumentar a potência ativa da máquina síncrona próximo do seu valor pré-falta, reduzindo o desequilíbrio entre o torque elétrico e mecânico. A estratégia de controle proposta foi testada experimentalmente, utilizando um inversor e uma montagem máquina síncrona-motor e, através da simulação de um sistema híbrido com um sistema fotovoltaico de grande porte. Os resultados mostram que a estratégia de controle proposta não está apenas em conformidade com os requisitos dos código da rede para melhorar a estabilidade da tensão durante uma perturbação grave, mas também é capaz de manter a estabilidade transitória da rede provando, assim, ser uma melhor alternativa em relação à capacidade FRT requerida pelos códigos de rede. / [en] The increase in photovoltaic generation has caused changes in the power system s operative and dynamic characteristics when subjected to severe disturbances. One of the most relevant problems associated with this renewable energy source is the transient stability, as renewable generation connected to the system by electronic converters does not contrinute to the increase of the total inertia of the system. However, electronic converters can potentially bring new opportunities for rapid control to support synchronous generators in response to severe disturbance. The present work proposes a control strategy for photovoltaic inverters based on the injection of the current with a major impact on the transient response of the synchronous machine rotor angle, identified through the eigenvalue sensitivity analysis and the participation factors. By doing so, it is possible to increase the synchronous machine active power output close to its pre-fault value, reducing the disequilibrium between mechanical and electrical torque. The proposed control strategy was experimentally tested using an inverter and a synchronous-motor machine assembly and, by simulating a hybrid system with a large photovoltaic system. The results show that the proposed control strategy not only conforms to the grid codes requirements to improve voltage stability during a severe disturbance, but is also able to maintain transient stability thus proving to be a better alternative to the FRT capability required by the grid codes.