• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 307
  • 107
  • 34
  • 21
  • 20
  • 10
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 583
  • 583
  • 315
  • 294
  • 125
  • 89
  • 80
  • 76
  • 70
  • 68
  • 64
  • 64
  • 60
  • 58
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
511

A influência da dimensão da abertura de saída da cozinha/serviço no potencial de ventilação dos ambientes de edificações multifamiliares em Maceió-AL / The outlet kitchen opening dimension influence on the natural ventilation potencial of Maceió-AL multifamily building environment

Sacramento, Alexandre da Silva 29 March 2012 (has links)
The design of residential buildings should have as an important criteria, the adoption of bioclimatic principles, taking into consideration the local climate in order to potentize the desirable characteristics of this climate as a means to meet the requirements for human comfort. In hot and humid climate, such Maceió-AL climate, natural ventilation as design strategy, it is important to the renewal of the air environment, for cooling the building envelop, to minimize energy costs, and to provide satisfactory levels of human thermal comfort. The performance of natural ventilation is strongly linked to the characteristics of the opening in buildings, which influence the potential of ventilation indoors. To make the air movement inside the building happen, it is necessary inlet and outlet openings. Few studies have addressed the potential provided by the ventilation outlet openings. This study sought to estimate the natural ventilation potential of multifamily residential building in Maceió-AL, varying the size of outlet openings of the kitchen/service for two types of urban roughness. To that end, was defined a Maceió - AL typical multifamily building, form which were varied the outlet openings size in the percentage of 10%, 15% and 25% based on the floor area and the middle section area of the environment. The results show that the natural ventilation potential for air quality was satisfactory in all cases. In relation to the recovery of comfort by natural ventilation, the results based on the floor area were close to those based on the middle section of the environment. Despite of the proximity of results, the outlet openings based on the middle section of the environment had a better performance / Fundação de Amparo a Pesquisa do Estado de Alagoas / O projeto de edificações residenciais deve ter como critério importante a adoção de princípios bioclimáticos, levando em consideração o clima da região, de forma a potencializar as características desejáveis desse clima como meio de preencher os requisitos de conforto humano. No clima quente e úmido, como é o caso do clima de Maceió-AL, a ventilação natural como estratégia de projeto, é importante para a renovação de ar do ambiente, para o resfriamento da edificação, para minimizar custos com energia elétrica e para proporcionar níveis satisfatórios de conforto térmico humano. O desempenho da ventilação natural está fortemente ligado às características das aberturas das edificações, que influenciam no potencial de ventilação dos ambientes internos. Para que ocorra o movimento de ar dentro de uma edificação, é necessário que existam aberturas de entrada e de saída. Poucos estudos abordam o potencial de ventilação proporcionado pelas aberturas de saída. Esta pesquisa pretendeu estimar o potencial de ventilação de edificações residenciais multifamiliares em Maceió Al, variando o tamanho das aberturas de saída do ar da cozinha/serviço para dois tipos de rugosidade urbana. Para tanto, foi definida uma tipologia de edificação multifamiliar predominante para Maceió-AL, a partir da qual foram variados os tamanhos das aberturas de saída na porcentagem de 10%, 15% e 25% em função da área do piso e da seção média do ambiente. Os resultados encontrados mostram que o potencial de ventilação para a qualidade do ar foi satisfatório em todos os casos. Em relação à restituição do conforto pela ventilação natural, os resultados para as aberturas baseadas na área do piso foram semelhantes aos resultados para as aberturas baseadas na seção média. Apesar da proximidade de resultados, as aberturas baseadas na seção média tiveram melhor desempenho no cômputo geral
512

Relações entre preferências térmicas humanas no interior de edificações e as temperaturas externas: um estudo sobre o método adotado na norma AHSRAE 55-2004 / Correlation between Indoor and Outdoor Human Thermal Preferences: A Study of the 55-2004 ASHRAE Standard Method

Gomes, Adriana Dias 09 March 2007 (has links)
Made available in DSpace on 2016-06-02T20:09:07Z (GMT). No. of bitstreams: 1 1612.pdf: 2927282 bytes, checksum: 0156961dd061931755aa12339ca3139f (MD5) Previous issue date: 2007-03-09 / Financiadora de Estudos e Projetos / Thermal comfort is specifically related to thermal behavior in response to both indoor and outdoor air temperature. Human thermal acceptability to climate changes and its effects depend on several aspects. It relies not only on local climatic conditions, but also on personal traits which can interfere seriously with thermal preferences as well as with someone s mental and physical performance. The combination of these factors determines the human thermal acceptability and the satisfaction degree in relation to a specific environment. The more those conditions vary, the higher the percentage of dissatisfied people with an environment is, due to personal requirements of each person. Thus, meeting those expectations of thermal comfort, considering people s needs and limitations, has been an important subject of studies in this field highlighting its importance when planning, designing, and constructing a building. Therefore, human thermal preferences and thermal sensations to hot and cold environments are essential information to various activity sectors because comfort and human performances depend directly on environmental thermal conditions. Since architecture, mainly buildings, is intended for humans, it can be said that it should satisfy its occupants, regarding local climate conditions. In order to have this, it s necessary to determine the comfort temperatures in which people develop better their work activities, optimizing their mental, physical, and intellectual well being. This research consists of a theoretical analytical study of the international large database, compiled by ASHRAE (1997), combining climate conditions with human thermal preferences and sensations. The methodology used by Richard De Dear (1997) in the RP-884 ASHRAE s project was the probit procedure using SAS software, release 8 (SAS Institute, Cary, NC, USA, 1999) to the optimum temperatures obtained, and linear regression to the acceptable comfort limits of the population studied. The comfort limits obtained demonstrate the ratio between occupants comfort temperature and the outdoor temperature, featuring fluctuations of 80% to 90% of thermal acceptability in well-ventilated buildings. The aim of this study is to interpret the method adopted by Richard De Dear (1997) and apply it to the data resulting from the large ASHRAE (2004) Database to understand how the comfort temperatures (optimum temperatures) and the thermal acceptability were obtained for a group of people under predetermined indoor thermal conditions in well- ventilated buildings. The Probit analysis indicates the optimum temperature is 25ºC approximated, exactly 0,5 probability responses, that is, 50% interviewees. In the face the obtained results, it s succeeded the Probit analysis applicability has a great efficacy method to binary variable probability study and determination, which points out two interesting situations to research / O termo conforto térmico abrange muitos fatores do comportamento térmico subjetivo na relação com o clima interno e externo. A aceitabilidade térmica do homem aos efeitos do clima depende de vários aspectos, não só das condições climáticas do local, mas também de fatores pessoais que podem interferir significativamente nas suas preferências térmicas, bem como no rendimento físico e mental do seu organismo. A interação destes dois grupos de fatores determina o grau de satisfação e aceitabilidade térmica do homem em relação a um determinado ambiente. Quanto maior a variação destas condições, maior será a porcentagem de insatisfeitos em um ambiente, devido às exigências pessoais de cada indivíduo. Assim, atender as expectativas do homem em relação ao conforto térmico, considerando suas necessidades e limitações, tem sido um dos focos de estudos nesta área, que destaca a importância do tema no planejamento, projeto e execução de edificações. As sensações e preferências térmicas humanas em relação ao calor e ao frio, portanto, constituem informação indispensável para inúmeros setores de atividades, pois o conforto e o desempenho humano dependem diretamente das condições térmicas dos ambientes. Sendo a arquitetura, em particular o edifício, feito para o homem, conclui-se que este deve atender satisfatoriamente ao usuário, dentro das condições climáticas locais. Para isto, é necessário conhecer as temperaturas de conforto sob as quais o homem melhor desenvolve suas atividades de trabalho, otimizando seu bem-estar físico, intelectual e mental. Esta pesquisa consiste em um estudo teórico analítico da ampla base internacional de dados, compilada pela ASHRAE (1997), relacionando condições climáticas do ar e sensações e preferências térmicas humanas. A metodologia utilizada por Richard De Dear (1997) no projeto ASHRAE RP-884 foi o procedimento probit no software SAS, versão 8 (SAS Institute, Cary, NC, USA, 1999) para as temperaturas preferidas obtidas, e de regressão linear para os limites de conforto aceitáveis pela população avaliada. Estes limites de conforto resultantes expressam a relação entre temperatura de conforto do usuário e temperatura externa do ar, apresentando variações de 80% e 90% de aceitabilidade térmica, em edifícios naturalmente ventilados. O objetivo geral desta pesquisa é interpretar o método adotado por De Dear (1997) e aplicá-lo nos dados obtidos da ampla Base de Dados da ASHRAE (2004), como fim de entender como foram obtidas as temperaturas de conforto (temperaturas preferidas) e a aceitabilidade térmica de pessoas submetidas a determinadas condições térmicas internas, em ambientes naturalmente ventilados. Os resultados da análise Probit mostram que a temperatura preferida é aproximadamente 25ºC, a exatamente 0,5 de probabilidade de respostas, ou seja, 50% dos entrevistados. Diante dos resultados obtidos, verificou-se a aplicabilidade da análise Probit, como um método de grande eficácia para o estudo e a determinação de probabilidades de variáveis binárias, as quais apontam duas situações de interesse para a pesquisa
513

Refrigeração evaporativa de telhados por meio de gotejamento de água. Experimento em bancada de testes.

Nascimento, Gustavo Rosas 09 December 2005 (has links)
Made available in DSpace on 2016-06-02T20:09:24Z (GMT). No. of bitstreams: 1 DissGRN.pdf: 2609082 bytes, checksum: 09147cf07533f0a088d8e1734fc80ee4 (MD5) Previous issue date: 2005-12-09 / Financiadora de Estudos e Projetos / The cooling effect of evaporation is used in dry climates buildings since ancient times. Water evaporation can remove heat of roofs, cooling the interior of buildings indirectly. This study presents the measurement results of a test bed which received two identical tiles, one of them receiving water application and the other kept dry. Its objective was to investigate the effects that the evaporation provokes on internal surface temperature of ceramic tiles and fibrocement tiles. Using regression analyses, strong correlations were found among the falls observed in tiles internal surface temperatures and the climatic conditions. The evaporation provoked reduction of until 18,7 oC in the ceramic roof and until 17ºC reduction in the fibrocement one. / O resfriamento evaporativo de ambientes é conhecido pelos habitantes de regiões de clima seco desde a antiguidade. A evaporação de água sobre coberturas retira calor das mesmas, refrigerando indiretamente o interior da edificação. Este trabalho apresenta resultados de um estudo em que foram medidos os efeitos que a evaporação provoca sobre as temperaturas superficiais internas de telhas de barro e de fibrocimento, sujeitas às variações climáticas como o vento e radiação solar. Para tanto, montou-se uma bancada de testes onde foram monitoradas telhas idênticas, uma com gotejamento de água e outra mantida seca, em situações de inverno em laboratório e em situações de verão em campo. Por meio de análise de regressão, identificou-se fortes correlações entre as quedas observadas nas temperaturas superficiais internas das telhas e as condições climáticas. A evaporação provocou redução de até 18,7 ºC na temperatura superficial interna da telha de barro e de até 17ºC na de telha de fibrocimento. Os resultados indicaram que o gotejamento de água sobre superfícies externas de telhas de barro e de fibrocimento reduz a temperatura superficial interna das mesmas por meio da refrigeração evaporativa, sendo um potencial método de resfriamento passivo de telhados de barro e de fibrocimento na região de São Carlos-SP.
514

Att bygga energisnålt med olika ventilationssystem / To build energy efficient with various ventilation systems

Bengtsdottir, Fanney, Hagerup Norrman, Christel January 2018 (has links)
Ett ventilationssystem i en byggnad ska tillföra en tillräcklig mängd frisk luft och skapa ett undertryck för att minska fuktrelaterade problem. Idag finns flera typer av ventilationssystem tillgängliga, några med värmeåtervinning, vilka bidrar med olika funktioner och begränsningar. Studien undersöker skillnaden mellan frånluftsventilation (F), frånluftsvärmepump (FVP) samt fläktstyrt till- och frånluftssystem med roterande återvinning (FTX) i NNE-hus. Tre enfamiljshus i Kronobergs län blev strategiskt utvalda för insamling av data, mätningar, intervjuer och beräkningar. Därefter gjordes en utvärdering och jämförelse mellan systemens prestanda med avseende på termisk komfort, luftomsättning, effektbehov, energianvändning och kostnader. Resultaten visar att kriterierna för termisk komfort uppfylls i samtliga hus under tiden för undersökningar och den specifika energiförbrukningen för de olika husen är mindre än hälften av det maximalt tillåtna. El- och värmeeffektbehovet är minst för F-systemet enligt resultaten men FVP är mest lönsam med hänsyn till återvinning. FVP är även mest lönsam med avseende på ackumulerade kostnader. Resultaten är begränsade för ett specifikt uteklimat under perioden för undersökningen. För en större översikt och tillförlitlighet i beräkningar rekommenderas studier som sträcker sig över ett år. / A ventilation system in a building provides sufficient amount of fresh air and create a negative pressure to reduce moisture-related problems. Today several ventilation systems, some with different energy recovery, are available and those inherence different features and limitations. This study examines differences between exhaust air ventilation without heat recovery (F), exhaust air heat pump (FVP) and exhaust and supply air ventilation with a rotating heat exchanger (FTX) in nearly zero-energy houses. Three single-family houses in Kronoberg County were strategically chosen for the data collection, measurements, interviews and calculations to evaluate and compare their system’s performances in terms of thermal comfort, air circulation, heat recovery effects, energy use and financial attractiveness. The results show that the criteria for thermal comfort are satisfied and the specific energy consumption are within the current requirements in all these houses. Under the period of investigation, the house without heat recovery requires minimum quantity of electricity for ventilation system where as the house with FVP is the most energy efficient. Also, the house with an FVP shows to be the most cost-efficient with lowest accumulated costs. The results are limited for a specific outdoor climate during the studied period. Therefore, examinations over a longer term in different contexts are recommended for a more comprehensive view.
515

Respostas fisiológicas de caprinos nativos em ambiente controlado. / Native caprines' physiological response in a controlled environment.

LUCENA, Luiz Felipe de Almeida. 15 July 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-07-15T21:13:18Z No. of bitstreams: 1 LUIZ FELIPE DE ALMEIDA LUCENA -TESE PPGEA 2012..PDF: 6885222 bytes, checksum: efcaf3742a1c9ace68da5e445634cef3 (MD5) / Made available in DSpace on 2018-07-15T21:13:18Z (GMT). No. of bitstreams: 1 LUIZ FELIPE DE ALMEIDA LUCENA -TESE PPGEA 2012..PDF: 6885222 bytes, checksum: efcaf3742a1c9ace68da5e445634cef3 (MD5) Previous issue date: 2012-02 / CNPq / Capes / Objetivou-se, neste trabalho, determinar as respostas fisiológicas de duas raças de caprinos nativos do semiárido brasileiro submetidos a ambiente termicamente controlado em câmara climática. Utilizaram-se 12 animais machos, dos quais 6 Canindés e 6 Moxotós, com pesos médios iniciais de 19,6 ± l,9kg e 20,4 + l,6kg , respectivamente, alimentados com dieta contendo 43% de feno de Tifton (Cynodon dactylon, (L) Pers) e 57% de concentrado. Os animais foram distribuídos num delineamento inteiramente casualizado em esquema fatorial (2 x 4 x 6), duas raças, quatro níveis de temperatura e seis repetições. Em cada repetição foram utilizadas quatro temperaturas (20,6, 24,8, 27,8 e 31,6 °C), com umidade relativa média do ar de 60 ± 5%, e velocidade do vento em 0,5m/s. Foram analisados os parâmetros fisiológicos frequência cardíaca, frequência respiratória, temperaturas do pelo, pele, temperatura retal além do consumo de alimento e água. Para cada temperatura estudada, os animais permaneceram quatro dias em aclimatação e três dias de coleta de dados, isto é, dez horas em confinamento e quatorze para recomposição das funções fisiológicas. Os animais se mantiveram dentro da zona de conforto térmico para as variáveis FC e FR nas temperaturas ambientes compreendidas entre 20,6 e 27,8 °C. A transição entre o estado de conforto e o início de estresse se inicia a 28,1 e 28,3 °C, respectivamente. As temperaturas ambiente compreendidas entre 20,4 e 31,6 °C não alteraram significativamente a TR fisiológica dos animais, sendo a mesma mantida em 39,5 ±0,18 °C, considerada normal para a espécie. A FR e a FC são as variáveis mais afetadas nas transições de estado de conforto para estresse térmico, e se mostraram como os mecanismos mais indicados como verificadores de desconforto térmico para caprinos Canindé e Moxotó, em condições ambientes controladas. A capacidade de consumo de alimento não é alterada significativamente em temperaturas ambiente compreendidas entre 20,4 e 31,6 °C, desde que mantidas as condições experimentais deste trabalho. O consumo de água é maximizado em temperatura ambiente média de 31,6 °C, possuindo correlação positivacom o aumento da FC e FR nesta temperatura / The objective of this research was to detennine the physiological response of two caprine races from the Brazilian semiarid, submitted to a thermically controlled climatic chamber. Twelve male animals were used, 6 Canindés e 6 Moxotós, with average weight of 19,6 + 1,9kg e 20,4 + 1,6kg respectively, fed with a diet containing 43% of Tifton hay (Cynodon dactylon, (L) Pers) and 57% of concentrated. The animals were distributed into an entirely casualised delineation, in factorial scheme (2 x 4 x 6), two races, four temperature levels and six repetitions. In each repetition four temperatures were utilized (20,6, 24,8, 27,8 e 31,6 °C), with the average relative air humidity of 60 + 5%, and wind speed of 0,5m/s. Physiological parameters such as cardiac frequency, respiratory frequency, fur temperature, skin, rectal temperature and water and food consumption were analyzed. For each studied temperature the animals stayed four days in acclimation and three days for data collecting, being ten hours in confinement and fourteen hours for recomposition of physiological functions. The animals stayed within the thermic comfort zone for the FC and FR variables in environmental temperatures between 20,6 e 27,8 °C. The transition between the state of comfort and stress begins respectively at 28,1 e 28,3 °C. The environment temperatures between 20,4 and 31,6 °C did not alter significantly the animal's physiological TR, that was maintained in 39,5 + 0,18 °C, which is considered normal for the species. The FR and the FC are the most affected variables in the transitions from the state of comfort to thermic stress and proved to be the best indicated mechanisms as verifiers of thermic discomfort for Canindé e Moxotó caprines in controlled environment conditions. The food consumption capability is not significantly altered in ambient temperatures between entre 20,4 e 31,6 °C, if the experimental conditions of this research are maintained. Water consumption is maximized in the environment average temperature of 31,6 °C, having a positive correlation with the increase of FC and FR at this temperature.
516

Efeitos de sistemas de criação e do ambiente sobre o desempenho e qualidade dos ovos de galinhas poedeiras. / Effects of systems and creation of environment on the quality and performance of egg laying hens.

CAMERINI, Nerandi Luiz. 18 June 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-06-18T13:31:40Z No. of bitstreams: 1 NERANDI LUIZ CAMERINI - TESE PPGEA 2012..pdf: 21432695 bytes, checksum: 7578d920d7cb372f971f067d26250bb6 (MD5) / Made available in DSpace on 2018-06-18T13:31:40Z (GMT). No. of bitstreams: 1 NERANDI LUIZ CAMERINI - TESE PPGEA 2012..pdf: 21432695 bytes, checksum: 7578d920d7cb372f971f067d26250bb6 (MD5) Previous issue date: 2012 / Capes / O objetivo geral desta pesquisa foi avaliar o bem-estar de aves poedeiras em dois diferentes sistemas de criação: gaiola enriquecida (GE) e sistema alternativo (SA) e a qualidade desses sistemas no que diz respeito aos aspectos comportamentais, fisiológicos e produtivos. O experimento foi desenvolvido na câmara climática do LaCRA - Laboratório de Construções Rurais e Ambiência, da Universidade Federal de Campina Grande - PB. A pesquisa constou de três períodos experimentais de 28 dias cada. Foram utilizadas 72 aves poedeiras da linhagem Dekalb White com 27 semanas de idade. O regime de luz adotado foi de 16 horas claro e 8 horas de escuro. O delineamento experimental adotado foi o inteiramente casualizado em esquema fatorial 2x3 (dois sistemas de criação e três condições ambientais (20 °C, 26 °C e 32 °C) com seis repetições e umidade relativa de 60%. A pesquisa analisou diferentes parâmetros: produção; aspectos fisiológicos; desempenho zootécnico; qualidade dos ovos e termografia. Técnicas de processamento e análise de imagens podem vir a colaborar com a busca de informações contidas em imagens de animais confinados. Os dois sistemas de criação utilizados nesta pesquisa não apresentaram grandes diferenças quanto as variáveis analisadas. O sistema de gaiola enriquecida e o sistema alternativo podem ser compatíveis no desempenho e na qualidade dos ovos produzidos. / The general objective of this research was to evaluate the welfare of laying hens in two different systems: Enriched Cage (EC) and Alternative System (AS) and the quality of these systems in relation of behavioral, physiological and productive aspects. The experiment was conducted in a climatic chamber of LaCRA - Laboratory of Rural Constructions and Ambience, in the Federal University of Campina Grande - Paraíba State, Brazil. The research consisted of three experimental periods of 28 days each one. It was used 72 birds of lineage Dekalb White at 27 weeks of age. The light regime was set at 16 hours light and 8 hours of darkness. The experimental design was completely randomized in 2x3 factorial (two creation systems and three environmental conditions: 20 °C, 26 °C and 32 °C) with six replicates and relative humidity of 60%. This research analyzed different parameters: production; physiological aspects; zootechnical performance; egg quality and thermography. Processing techniques and image analysis may come to contribute to the search for information contained in images of confined animais. Both creation systems used in this study showed no large differences in the variables analyzed. Both systems may be compatible in performance and quality of eggs produced.
517

An?lise bioclim?tica do bairro do Renascen?a II S?o Luis-MA: realidade e perspectiva do conforto t?rmico em espa?os externos / Bioclimatic assessment of the Renascen?a II Neighborhood in S?o Luis Maranh?o, Brazil: reality and perspective of thermal comfort in outdoors

Trinta, Patr?cia Vieira 28 February 2007 (has links)
Made available in DSpace on 2014-12-17T13:56:56Z (GMT). No. of bitstreams: 1 PatriciaVT_capa_ate_cap1_.pdf: 2021691 bytes, checksum: 8f29e932ee450f2f59d070013ff553ae (MD5) Previous issue date: 2007-02-28 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascen?a II s microclimate in S?o Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascen?a II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the S?o Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28?C and 30,71?C. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants / O presente trabalho parte das preocupa??es com as condi??es de conforto t?rmico dos espa?os externos em cidades de clima quente-?mido, entendendo que a qualidade de vida neste ambiente ? fruto do tipo de objeto urbano constru?do para a viv?ncia humana em um meio ambiente com clima e caracter?sticas morfol?gicas espec?ficas. Apresenta-se como objeto de estudo a correla??o entre o microclima do Bairro do Renascen?a II em S?o Luis/MA, cidade de clima quente ?mido frente ?s mudan?as nas caracter?sticas morfol?gicas urbana e o ?ndice de satisfa??o de conforto t?rmico dos usu?rios dos espa?os externos do bairro em quest?o. Tem como objetivo geral diagnosticar a maneira como as transforma??es ocasionadas pela urbaniza??o influenciam o microclima do Renascen?a II, identificando ?reas cr?ticas da ?rea estudada, a fim de contribuir com recomenda??es de uso e ocupa??o do solo baseadas em conceitos de arquitetura bioclim?tica e fornecer subs?dios a futuras decis?es projetuais urbanas adequadas ao clima quente e ?mido de S?o Luis-MA. Apresenta-se como fundamenta??o te?rica o clima urbano, seus conceitos, elementos formadores e condicionantes. Em seguida, os condicionantes do conforto t?rmico e seus modelos de predi??o de sensa??o de conforto t?rmico em espa?os externos. Foram levantados os modelos preditivos de conforto e estresse t?rmico como ferramenta junto ? an?lise bioclim?tica. E finalmente a utiliza??o da an?lise bioclim?tica no diagn?stico do conforto t?rmico de ?reas urbanas, com sua efic?cia na identifica??o de locais que necessitam de mudan?as quanto ao conforto ambiental, merecendo aten??o ou at? prote??o; e suas estrat?gias na busca por cidades mais adequadas ao seu meio natural, resultando no urbanismo bioclim?tico. A metodologia aplicada baseou-se nos estudos de Katzschner (1997), complementados por Oliveira (1988) e Bustos Romero (2001) que sugerem uma an?lise e avalia??o de mapas de topografia, altura das edifica??es, uso do solo, ?reas verdes e tipo de cobertura do solo, para superposi??o e identifica??o de pontos para medi??o; a partir da? uma an?lise quantitativa com aferi??o das vari?veis ambientais (temperatura e umidade do ar, a velocidade e a dire??o dos ventos) nos pontos escolhidos. Percebeu-se que o bairro do Renascen?a II n?o possui ?reas de perman?ncia como pra?as e parques, as suas ?reas externas possuem pouca arboriza??o e apresenta alto ?ndice de impermeabilidade e alta densidade construtiva. A maioria dos entrevistados disse estar confort?vel em uma faixa de temperatura do ar entre 27,28? e 30,71?C. ? importante a elabora??o de um plano diretor para o bairro, definindo de estrat?gias para melhoria da qualidade de vida de seus habitantes
518

Ganho de peso e rendimento de carcaça de bovinos de corte confinados com acesso a sombra

Lopes, Antônio Carlos Rodrigues 06 October 2009 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / CHAPTER 2: It evaluated itself the effect of the shade, in commercial feedlot beef cattle, about the average weight gain (AWG) and performance of carcass. They were utilized 156 animals Nelores (Bos Indicus) and Nelore-cross, with average initial weight 396 kg, divided in two pens, a shading with 90 animals (handling) and another not shady with 66 (witness); counts on occurred in two moments to the 77 days and to the 118 days of confinement. The food composed itself of a feed with urea, crumb of soy and supplement premix of a commercial brand, that was placed on top to the sorghum tillage and added of lump of cotton and sorghum in grain shredded and supplied "ad-libitum". It determined itself the extreme temperatures (maximum and most minimum); temperature of the dry bulb and wet bulb; temperature of the Black Globe Thermometer in the shade and to the sun; speed of the wind and precipitation. These facts were utilized in the determination of four indices of thermal environment (Temperature-Humidity Index - THI; Wet Bulb Globe Temperature - WBGT; Equivalent Temperature Index - ETI and Heat Load Index - HLI) for verification of the possibility of thermal stress. The animal performance was obtained by the weighing in the beginning of the confinement and when the animals were sold; also was considered the performance of carcass to the 118 days, in the second counts on. It applied analysis of variance and Tukey´s Test at 5%, being the variable I earn of weight corrected by the co-variance by means of the initial weight. Bovines Nelore and Nelore-cross, confined commercially with access in the shade, gains more of weight with 77 days. With 118 days the difference in earn of weight was not significant, but the performance of carcass of the animals of the shady pen was bigger. / CAPÍTULO 2: Avaliou-se o efeito da sombra, em confinamento comercial de bovinos, sobre o ganho de peso médio (GPM) e o rendimento de carcaça. Foram utilizados 156 animais nelores e anelorados, com peso inicial médio de 396 kg, divididos em dois currais, um sombreado com 90 animais e outro não sombreado com 66. O abate ocorreu em dois momentos, aos 77 dias e aos 118 dias de confinamento. A alimentação compunha-se de uma ração com uréia, farelo de soja e núcleo de uma empresa comercial, que era sobreposta à silagem de sorgo e acrescida de caroço de algodão e sorgo em grão triturado e fornecida ―ad-libitum‖. Determinaram-se as temperaturas extremas (máxima e mínima); temperatura do bulbo seco e bulbo úmido; temperatura do globotermômetro à sombra e ao sol; velocidade do vento e índice pluviométrico. Estes dados foram utilizados na determinação de quatro índices de ambiente térmico (Índice de Temperatura e Umidade - ITU; Índice de Temperatura e Globo Úmido - ITGU; Índice de Temperatura Equivalente - ITE e Índice de Carga Térmica - ICT) para verificação da possibilidade de estresse térmico. O desempenho animal foi obtido pela pesagem no início do confinamento e no momento da venda dos animais. Também foi considerado o rendimento de carcaça aos 118 dias. Aplicou-se análise de variância e Teste de Tukey a 5%, sendo a variável ganho de peso corrigida pela covariância por meio do peso inicial. Concluiu-se que o acesso à sombra de animais da raça nelore e anelorados, confinados comercialmente, favorece maior ganho de peso aos 77 dias e maior rendimento de carcaça aos 118 dias de confinamento. / Mestre em Ciências da Veterinárias
519

Escolha do índice de estresse térmico e da origem dos dados do ambiente térmico para avaliar o estresse por calor em bovinos leiteiros em ambiente tropical / Selection of the thermal stress index and the origin of the data of the thermal environment to evaluate the heat stress in dairy cattle in tropical environment

Brettas, Patrícia Kelly de Moraes 14 November 2017 (has links)
Primeiramente objetivou-se neste estudo examinar dentre os principais índices de estresse térmico qual melhor reflete o potencial impacto das condições meteorológicas sobre a homeostase térmica de novilhas leiteiras mestiças. Oito animais foram expostos ao sol das 9h00 às 13h00 em novembro e dezembro de 2016, janeiro e fevereiro de 2017, em Uberlândia, MG, Brasil. Após, foram medidas a frequência respiratória e a temperatura retal. Simultaneamente, foram quantificadas as temperaturas de bulbo seco e bulbo úmido, temperatura do globo negro e velocidade do vento. Em seguida, foram calculados a radiação solar, a umidade relativa, a temperatura radiante média e dez índices de estresse térmico. Os mesmos foram correlacionados com as variáveis fisiológicas e o Índice de Temperatura Equivalente apresentou as maiores correlações, seguido pelo Índice de Estresse Térmico para Vacas e pelo Índice de Estresse Ambiental. Na segunda pesquisa, determinaram-se os valores de temperatura do ar, umidade relativa e Índice de Temperatura e Umidade (ITU) de uma propriedade rural de produção de leite a pasto e da estação meteorológica oficial mais próxima, confrontando-os. Na fazenda, as leituras dos dados foram registradas por uma estação meteorológica automática, a cada cinco minutos, de fevereiro de 2015 a setembro de 2016. Depois, calcularam-se a média por hora e o ITU horário. Selecionaram-se os valores diários mínimo, médio e máximo. O mesmo foi feito com os dados da estação meteorológica oficial, que foram horários. A temperatura mínima e média na estação meteorológica foram maiores que na fazenda, respectivamente, durante todo período experimental e em 16 meses. A temperatura máxima da propriedade rural foi maior que a da estação em seis meses. Já a umidade relativa mínima, média e máxima da estação meteorológica foram inferiores às da fazenda. O ITU mínimo foi maior na estação oficial e o ITU máximo superior na fazenda em todos os meses. Por fim, o número de dias com um ITU máximo igual ou superior ao ITU crítico foi maior na fazenda. Assim, dados da estação meteorológica oficial subestimam o efeito do estresse por calor. / Firstly, the objective of this study was to examine among the main heat stress indexes which ones best reflect the potential impact of meteorological conditions on the thermal homeostasis of half-blood dairy heifers bred. Eight animals were exposed to direct sunlight from 9h00 to 13h00 in November and December of 2016 and January and February of 2017, in Uberlândia, MG, Brazil. After, the respiratory rate and the rectal temperature were measured. Simultaneously, the temperatures of dry bulb and wet bulb, as well as that of black globe, were quantified, as was the wind speed. Afterwards, the solar radiation, the relative humidity, the mean radiant temperature and ten stress indexes were calculated. They were correlated with the physiological variables and the Equivalent Temperature Index presented the highest amount of meaningful correlations, followed by the Cattle Heat Stress Index and the Environmental Stress Index. In a second research, the values of air temperature, relative humidity and Temperature Humidity Index (THI) of one rural property with milk production at pasture and those from the nearest official weather station were determined, confronting them. At the farm, data readings were recorded by an automatic weather station, every five minutes, from February 2015 to September 2016. Then, the hourly average and hourly THI were calculated. The minimum, average and maximum daily values were selected. The same was done with data from the official weather station, which were times. The minimum and mean temperature in the meteorological station were higher than on the farm, respectively, throughout the experimental period and in 16 months. The maximum temperature of the rural property was greater than that of the station in six months. Meanwhile, the minimum, average and maximum relative humidity of the meteorological station were lower than those of the farm. The minimum THI was higher at the official station and the maximum THI higher at the farm in every month. Finally, the number of days with a maximum THI equal to or greater than the critical THI was higher on the farm. Thus, data from the official weather station underestimate the effect of heat stress. / Dissertação (Mestrado)
520

Campo térmico urbano e a sua relação com o uso e cobertura do solo em uma cidade tropical úmida.

SANTOS, Joel Silva dos. 28 September 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-09-28T20:00:01Z No. of bitstreams: 1 JOEL SILVA DOS SANTOS - TESE (PPGRN) 2011.pdf: 5220762 bytes, checksum: 35f8c4b7ea7bb6b3e7c706a4b11bea0d (MD5) / Made available in DSpace on 2018-09-28T20:00:01Z (GMT). No. of bitstreams: 1 JOEL SILVA DOS SANTOS - TESE (PPGRN) 2011.pdf: 5220762 bytes, checksum: 35f8c4b7ea7bb6b3e7c706a4b11bea0d (MD5) Previous issue date: 2011-12-19 / As alterações ocorridas no sistema climático urbano das grandes cidades são processos relacionados ao adensamento urbano e às diferentes formas de uso e cobertura do solo. O objetivo deste trabalho foi analisar o campo térmico urbano e a sua relação com as diversas formas de uso e cobertura do solo em cidade tropical úmida, especificamente a cidade de João Pessoa, PB. As medições da temperatura do ar e umidade relativa foram realizadas em dois períodos distintos de três meses (seco e chuvoso), utilizando-se termo-higrômetro da marca Hobos em nove pontos representativos da malha urbana de cidade. O nível de estresse térmico foi avaliado com base no índice de desconforto de Thom (IDT) para regiões tropicais, ajustado através de questionários de avaliação da sensação térmica das pessoas nos pontos monitorados. O teste de Mann-Kendall foi utilizado para avaliar a tendência temporal das séries climatológicas de temperatura, umidade relativa do ar e do IDT no período de 1963 a 2011. Os tipos de cobertura de solo de cada ponto monitorado foram classificados dentro de nove classes de acordo com a percentagem de vegetação e de materiais permeáveis e impermeáveis utilizando métodos quantitativos e qualitativos. Os resultados do trabalho indicam que a faixa de classificação do índice de desconforto de Thom não é apropriada para regiões tropicais úmidas. A ilha de calor urbano é um fenômeno que ocorre preferencialmente durante o período noturno enquanto a intensidade máxima dos gradientes de temperatura e umidade relativa do ar são fenômenos essencialmente diurnos. Os cenários dos níveis de conforto térmico indicam condições de forte desconforto ambiental para os anos de 2050 e 2060 durante o período seco e desconfortável para o período chuvoso no ano de 2060 em toda área de estudo. / The changes in the urban climate system in great cities are processes related to urban density and the different forms of use and land cover. The objective of this study was to analyze the thermal urban field and its relation to the various forms of use and land cover in a humid tropical city, specifically Joao Pessoa city, PB, Brazil. Measurements in air temperature and relative humidity were carried out in two distinct periods of three months (dry and wet seasons), using thermo-hygrometer Hobos located in nine representative areas of the city. The level of heat stress was evaluated based on Thom's discomfort index (IDT, in Portuguese), adjusted for tropical regions based on questionnaires for assessing the thermal sensation that people have in function to the parameters that determine the environment in which they live. Mann-Kendall test was used to assess the temporal trends of time series in temperature, relative humidity and IDT for the period from 1963 to 2011. The types of ground cover of each monitored point were classified into nine classes according to the percentage of vegetation coverage and permeable and impermeable materials by utilizing both qualitative and quantitative methods. The results of the study indicated that the classification range of the Thom’s discomfort index is not suitable for humid tropical regions. The urban heat island is a phenomenon that occurs preferentially during the night while the maximum intensity of the temperature and relative humidity gradients are essentially diurnal phenomena. The scenarios of the thermal comfort levels indicated a strong discomfort for the 2050 and 2060 years during the dry season and uncomfortable condition during the rainy season in the 2060 year throughout the study area.

Page generated in 0.0954 seconds