• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 118
  • 8
  • 3
  • 1
  • Tagged with
  • 130
  • 45
  • 36
  • 31
  • 28
  • 27
  • 24
  • 22
  • 22
  • 22
  • 22
  • 22
  • 22
  • 18
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Fotónica de microondas aplicada a la interferometría de baja coherencia

Benítez González, Jesús 25 June 2019 (has links)
[ES] La interferometría de baja coherencia (Low Coherence Interferometry, LCI) es una técnica óptica de medida de distancias capaz de alcanzar resoluciones del orden de las micras en la dirección axial de la muestra. Su principio físico está basado en la generación de un patrón de interferencia que, tras ser procesado, permite obtener la información estructural de la muestra estudiada. Entre las aplicaciones de LCI, destaca el área de la medicina, principalmente debido a la naturaleza no invasiva de la técnica. En este sentido, la aplicación más reconocida es la tomografía de coherencia óptica (Optical Coherence Tomography, OCT), donde la obtención de imágenes en 2D y 3D mediante el uso de LCI permite realizar análisis y diagnósticos de diferentes tejidos biológicos. Entre otros campos de aplicación de esta técnica se encuentran el sensado o la caracterización de componentes ópticos. Sin embargo, existen también limitaciones asociadas a los sistemas LCI como su gran volumen y coste, sobre todo cuando se aplica al campo de la medicina, donde son necesarias estructuras ópticas más complejas. Asimismo, existe una importante limitación relacionada con el patrón de interferencia, ya que éste se captura en el dominio óptico donde es altamente sensible a las variaciones de temperatura o las vibraciones. Por estos motivos, el objetivo principal de esta tesis doctoral se centra en el estudio de la técnica LCI a través de su combinación con el campo de la fotónica de microondas (Microwave Photonics, MWP). Las ventajas que puede aportar el campo MWP a LCI son numerosas, donde se puede destacar el análisis del patrón de interferencia en el dominio eléctrico en lugar de en el óptico, o la posibilidad de hacer uso de una tecnología mucho más madura como es la fotónica de microondas. El principio de operación de la técnica, denominada como MWP-LCI, está basado en el análisis de la función de transferencia del sistema cuando se considera una muestra concreta. Las características estructurales de dicha muestra generan diferentes resonancias de RF cuya posición y anchura dentro del espectro eléctrico se relacionan directamente con las diferentes capas de las que está compuesta la muestra. En este sentido, la tesis doctoral se centra, en primer lugar, en la demostración de la analogía existente entre las técnicas LCI y MWP-LCI. Posteriormente, se realizan diferentes propuestas de mejora y evolución a la estructura MWP-LCI más básica. Mediante el análisis teórico de dichas propuestas se demuestra que el uso de los conocimientos del área MWP permite superar las limitaciones ligadas a las primeras propuestas realizadas en MWP-LCI. Asimismo, se incluyen las demostraciones experimentales asociadas a todas las propuestas realizadas, alcanzando un excelente grado de concordancia con los resultados teóricos. Por último, se centra el análisis en los elementos clave que componen estas estructuras: la muestra, la fuente óptica y el elemento dispersivo. A través de las distintas evoluciones realizadas a la técnica MWP-LCI se ha podido demostrar experimentalmente que las sensibilidades alcanzadas se sitúan en torno a los 60 dB junto a resoluciones de 28 µm, siendo sencillo superar 1 cm de rango de operación. / [CA] La interferometria de baixa coherència (Low Coherence Interferometry, LCI) és una tècnica òptica de mesura de distàncies capaç d'abastar resolucions de l'ordre de les micres en la direcció axial de la mostra. El seu principi físic es basa en la generació d'un patró d'interferència que, en ser processat, permet obtindre la informació estructural de la mostra estudiada. Entre les aplicacions d'LCI, destaca l'àrea de la medicina, principalment a causa de la naturalesa no invasiva de la tècnica. En aquest sentit, l'aplicació més reconeguda és la tomografia de coherència òptica (Optical Coherence Tomography, OCT), en què l'obtenció d'imatges en 2D i 3D mitjançant l'ús d'LCI permet portar a terme anàlisis i diagnòstics de diferents teixits biològics. Entre altres camps d'aplicació d'aquesta tècnica hi ha el sensat o la caracterització de components òptics. Tanmateix, hi ha també limitacions associades als sistemes LCI, com la grossària i el cost, sobretot quan s'aplica al camp de la medicina, en què són necessàries estructures òptiques més complexes. Així mateix, hi ha una limitació important relacionada amb el patró d'interferència, ja que aquest es captura en el domini òptic on és altament sensible a les variacions de temperatura o les vibracions. Així doncs, l'objectiu principal d'aquesta tesi doctoral se centra en l'estudi de la tècnica LCI a través de la seua combinació amb el camp de la fotònica de microones (Microwave Photonics, MWP). En són nombrosos, els avantatges que pot aportar el camp MWP a LCI, entre els quals es pot destacar l'anàlisi del patró d'interferència en el domini elèctric en comptes d'en l'òptic, o la possibilitat de fer ús d'una tecnologia molt més madura, com és la fotònica del microones. El principi d'operació de la tècnica, que s'anomena MWP-LCI, es basa en l'anàlisi de la funció de transferència del sistema quan es considera una mostra concreta. Les característiques estructurals de la susdita mostra generen diferents ressonàncies d'RF, i la seua posició i amplària dins de l'espectre elèctric es relacionen directament amb les diferents capes de què està composta la mostra. En aquest sentit, la tesi doctoral se centra, en primer lloc, en la demostració de l'analogia que existeix entre les tècniques LCI i MWP-LCI. Tot seguit, es porten a terme diferents propostes de millora i evolució a l'estructura MWP-LCI més bàsica. Mitjançant l'anàlisi teòrica de les esmentades propostes es demostra que l'ús dels coneixements de l'àrea MWP permet superar les limitacions lligades a les primeres propostes fetes en MWP-LCI. De la mateixa manera, s'inclouen les demostracions experimentals associades a totes les propostes fetes, amb la qual cosa s'ha assolit un excel·lent grau de concordança amb els resultats teòrics. Finalment, l'anàlisi se centra en els elements clau que componen aquestes estructures: la mostra, la font òptica i l'element dispersiu. A través de les diferents evolucions realitzades a la tècnica MWP-LCI s'ha pogut demostrar experimentalment que les sensibilitats assolides se situen al voltant dels 60 dB junt amb resolucions de 28 µm, tot sent senzill superar 1 cm de rang d'operació. / [EN] Low Coherence Interferometry (LCI) is an optical technique for distance measurements, able to reach the micron scale of resolution in the axial direction of the sample. Its physical principle is based on the generation of an interference pattern which, after processing, can reveal the structural information of the sample studied. Among all the LCI applications, the medical field arises as one of the most relevant, mainly due to the non-invasive nature of the technique. In this sense, the Optical Coherence Tomography (OCT) is one of the most recognizable applications, where the acquisition of 2D and 3D images by using LCI enables the analysis and diagnosis of different biological tissues. Among other fields of application of this technique, we can highlight sensing and the optical components characterization. Nevertheless, LCI systems also suffer from some limitations related to compactness and cost-effectiveness, mainly when it is applied to the medical field where more complex structures are required. Furthermore, it also exists a strong limitation related to the interference pattern mostly due to its acquisition in the optical domain, where it is highly sensitive to vibrations and temperature variations. On this basis, the main objective of this Ph.D. is focused in the study of the LCI technique and its combination with the field of Microwave Photonics (MWP). The benefits that MWP can offer to LCI are numerous, among which we can highlight the analysis of the interference pattern in the electrical domain instead of in the optical domain, or the possibility to make use of a more mature technology as the field of MWP is. The principle of operation of this technique, labelled as MWP-LCI, is based on the analysis of the interference pattern of the system when a certain sample is considered. The structural features of that sample generate different RF resonances where their position and width in the electrical spectrum are directly related to the different layers that compose the sample. In this way, the current Ph.D. is focused, firstly, in the demonstration of the existing analogy between the LCI and MWP-LCI techniques. Afterwards, several upgrade proposals are made to develop the most basic MWP-LCI structure. By the corresponding theoretical analysis of those proposals, it is demonstrated that the use of the MWP field allows the possibility to improve the limitations related to the first demonstrations carried out in MWP-LCI. Moreover, the experimental demonstrations associated to all the proposals are included, showing an excellent agreement with the theoretical results. Finally, the analysis is focused in the key elements that compose these structures: the sample, the optical source and the dispersive element. Through the different improvements applied to the MWP-LCI technique, we have been able to experimentally demonstrate a sensitivity level of 60 dB with resolutions of 27 µm in a working range that can easily exceed 1 cm. / Benítez González, J. (2019). Fotónica de microondas aplicada a la interferometría de baja coherencia [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/123054
102

Galio-68 como radiomarcador en el diagnóstico por imágenes

Cueva Benavides, Josemar 21 February 2024 (has links)
El isótopo de galio-68 ha tenido un gran aumento en investigaciones relacionadas a su uso en el diagnóstico por imágenes moleculares. Uno de los grandes factores a su favor es su uso en tomografía por emisión de positrones (PET), una técnica de imagen molecular que ha incrementado en popularidad debido a su superioridad en calidad de imagen frente otras técnicas. Por otro lado, las propiedades químicas y físicas del 68Ga son conocidas y favorables tanto para su uso en centros clínicos como para el desarrollo de nuevos radiofármacos. Estas propiedades son, por ejemplo, su química de coordinación sencilla y su tiempo de vida media favorable para las imágenes PET. Por otro lado, los generadores de 68Ge/68Ga han hecho posible la descentralización del 68Ga de manera que los centros de imagen ya no requieren un ciclotrón para su obtención. Estas características han propiciado que algunos radiofármacos de galio se hayan establecido como estándar para el diagnóstico de enfermedades como los tumores neuroendocrinos o el cáncer de próstata ya que muestran resultados superiores a otros radiofármacos. Otra área de interés para el desarrollo de nuevos radiofármacos de 68Ga es el diagnóstico de la enfermedad de Alzheimer y otras enfermedades neurodegenerativas. A diferencia del cáncer, aún no hay radiofármacos de 68Ga aprobados para el diagnóstico de esta enfermedad, pero existen múltiples propuestas de investigación con decenas de nuevos complejos siendo investigados cada año. / Trabajo de investigación
103

Characterization of Dedicated PET Equipment with Non-Conventional Geometry

Cañizares Ledo, Gabriel 28 July 2022 (has links)
[ES] Desde su creación en la década de 1950, las imágenes tomográficas han resultado muy valiosas en el ámbito médico ayudando tanto en el diagnóstico como en el tratamiento de múltiples enfermedades. Dentro de la imagen molecular, los escáneres PET (Tomografía por Emisión de Positrones) generan información detallada de la interacción de los radio-trazadores con el tejido de estudio, pudiendo combinar dicha información con imagen anatómica de escáneres TC (Tomografía Computarizada) o RM (Resonancia Magnética). Con el fin de aumentar las prestaciones de estos equipos, como la sensibilidad y la resolución espacial, los PET de cuerpo completo recientemente aumentan su cobertura axial. Sin embargo, el precio de estos dispositivos se multiplica, dificultando su compra en muchos hospitales y centros de investigación. Como alternativa, los escáneres PET específicos de órganos manejan un menor número de detectores haciéndolos más económicos. El objetivo de este tipo de escáneres es mejorar el rendimiento de los dispositivos acercando los detectores al paciente lo máximo posible, optimizando su diseño para un órgano en específico. Otra ventaja es la posible portabilidad de los aparatos. En esta tesis introducimos dos posibles diseños de PET específicos orientados a distintos órganos y con diferente tecnología y geometría y además un escáner preclínico con una geometría novedosa. El primer escáner fue construido de un proyecto nacional llamado PROSPET, fue diseñado y optimizado para hacer imagen de la próstata, debido a la conocida elevada tasa de cáncer de próstata en hombres. El 17% de la población masculina sufrirá cáncer de próstata. El detector escogido para este diseño está compuesto por cristales centelladores monolíticos acoplados a una matriz de fotomultiplicadores de silicio. Inicialmente se pensó en crear un escáner compuesto por dos palas. Sin embargo, los resultados con pacientes no fueron satisfactorios debido a la falta de información angular y la ausencia de información temporal precisa en los detectores. Por tanto, se construyó una configuración de anillo con un diámetro reducido en comparación con escáneres de cuerpo completo. Se apreció un aumento en la sensibilidad y la resolución espacial, así como una buena calidad de imagen utilizando fantomas. El segundo escáner, llamado proyecto CardioPET, está orientado a visualizar el corazón cuando el paciente está sometido a condiciones de estrés farmacológico. Para este dispositivo se utilizó el diseño de dos palas, pero usando cristales pixelados, mejorando la resolución temporal, permitiendo implantar algoritmos de tiempo de vuelo. Se han montado y testeado dos palas tanto con simulaciones como experimentalmente con buenas prestaciones. Además, se procedió a registrar el movimiento de las fuentes de radiación con el fin de aplicar correcciones de movimiento con la ayuda de una cámara externa y unos marcadores ARUCO. Los algoritmos de corrección de movimiento fueron testeados, demostrando un buen funcionamiento. El último dispositivo fue diseñado para optimizar la configuración PET de anillo lo máximo posible. Para ello, se eliminaron los espaciados entre detectores en un escáner pequeño de animales, creando un único detector centellador de forma cilíndrica. Con esto se busca aumentar la sensibilidad, pues ya no se pierden interacciones en los huecos, y también la resolución espacial. Dos prototipos fueron testeados con simulaciones, y validados experimentalmente. El primero con caras de salida planas y el segundo totalmente cilíndrico. En ambos diseños se observaron efectos debidos a la curvatura del detector que necesariamente han de ser compensados con una calibración. / [CA] Des de la seua creació en la dècada de 1950, les imatges tomogràfiques hi han resultat molt valuoses en àmbit mèdic ajudant tant en el diagnòstic com en el tractament de moltes malalties. Dins de la imatge molecular, els escàners PET (Tomografia per Emissió de Positrons) generen informació detallada de la interacció dels traçadors amb el teixit del pacient, podent combinar aquesta informació amb imatge anatòmica d'escàners TC (Tomografia Axial Automatitzada) o RM (Ressonancia Magnètica). Amb el fi d'augmentar les prestacions d’aquests equips, els PET de cos complet augmenten la seua cobertura axial, multiplicant el preu dels dispositius i dificultant la seua compra en hospitals i centres d’investigació. Com a alternativa, els escàners PET específics d'òrgans utilitzen un menor nombre de detectors resultant així un preu més econòmic. Un altre avantatge és la possible portabilitat dels aparells. En aquesta tesi abordem tres possibles dissenys de PET específics orientats a diferents òrgans i amb diferent tecnologia i geometria. El primer de tots, un projecte nacional denominat PROSPET, ha sigut dissenyat i optimitzat per a fer imatge de la pròstata, ja que és molt coneguda l'elevada taxa de càncer de pròstata en homes. El 17% de población masculina patirà càncer de pròstata. El detector escollit per a aquest disseny està format per cristals centellejadors monolítics acoblats a una matriu de fotomultiplicadors de silici. De primeres es va pensar a crear un escàner compost per dues pales, ja que permetria disposar els detectors molt a prop del pacient. El resultat no va ser molt satisfactori a causa de la falta d'informació angular i l'absència d'informació temporal precisa. Per tant, l'última iteració va consistir en una configuració d'anell amb un diàmetre reduït en comparació amb els escàners de cos complet. Es va observar una millora en la sensibilitat i la resolució espacial, així com una qualitat d'imatge acceptable. El segon dispositiu va ser dissenyat per a optimitzar la configuració d'anell el màxim possible. Per això es van llevar els espaiats entre detectors, creant un únic detector de forma cilíndrica. Amb aquest disseny es busca augmentar la sensibilitat, ja que no es perden interaccions en els espaiats, i també la resolució espacial. Dos prototips van ser testejats amb simulacions i validats experimentalment. El primer amb cares d'eixida planars i el segon totalment cilíndric. En els dos dissenys es va observar efectes deguts a la curvatura del detector que necessàriament ha de ser compensat amb una calibració. L’últim escàner, denominat projecte CardioPET, està orientat a visualitzar el cor durant el pacient quan és sotmés a condicions d'estrés farmacologic. escàner, denominat projecte CardioPET, està orientat a visualitzar el cor durant el pacient quan és sotmés a condicions d'estrés. Es va recuperar el disseny de les pales per aquest dispositiu, però utilitzant cristals pixelats, millorant la resolució temporal. Dues pales van ser muntades i testejades tant amb simulacions com experimentalment amb bones prestacions. A més, es va registrar el moviment de les fonts de radiació amb la fi d'aplicar correcció de moviment amb l'ajuda d'una càmera externa i uns marcadors ARUCO. Els algoritmes de correcció de moviment també van ser testejats, demostrant un bon funcionament. L'últim dispositiu va ser dissenyat per a optimitzar la configuració d'anell el màxim possible. Per això es van llevar els espaiats entre detectors, creant un únic detector de forma cilíndrica. Amb aquest disseny es busca augmentar la sensibilitat, ja que no es perden interaccions en els espaiats, i també la resolució espacial. Dos prototips van ser testejats amb simulacions i validats experimentalment. El primer amb cares d'eixida planars i el segon totalment cilíndric. En els dos dissenys es va observar efectes deguts a la curvatura del detector que necessàriament ha de ser compensat amb una calibració. / [EN] Since their introduction in the 1950-decade, tomographic images have become very valuable in the medical field helping both in diagnostics and in a variety of illnesses treatment. In the molecular imaging field, Positron Emission Tomography (PET) provides accurate information of the radio-tracers interactions with the patient tissue. Moreover, it is possible to combine this information with anatomical images provided by CT (Computed Tomography) or MR (Magnetic Resonance) scanners. With the aim to improve PET systems performance, such as the spatial resolution and the sensitivity, whole body (WB) PET scanners with large axial coverage are recently proposed. However, the system cost increases and, thus, makes difficult their installation in many hospitals or research centers. Organ-dedicated PET scanners, as an alternative to such large systems, use a lower number of detectors, so their price is considerably more economical. The goal of this kind of systems is to boost PET performance by placing the detectors as close as possible to the patient, optimizing the design for a specific organ instead of a large volume. Other advantage of these scanners is their portability. In this thesis we have worked in the design and validation of two organ-dedicated PET scanners with different geometries and technologies, as well as in a novel pre-clinical PET. The first scanner was the result from a national project called PROSPET. A PET system was designed and optimized to image the prostate area. Notice there is a high incidence rate of prostate cancer in the male population. 17% of male population will suffer prostate cancer. For this scanner, the detector modules were composed by a monolithic LYSO scintillation block coupled to a photosensor array based on silicon photomultipliers (SiPM). The first design configuration was made by two panels. However, patient results were not satisfactory due to the lack of angular information and the poor detector time resolution. Therefore, it was rebuilt in a ring configuration with a reduced diameter in comparison with WB-PET scanners. A high sensitivity and spatial resolution were found, as well as a good image quality using phantoms. The second PET scanner, called CardioPET, also arose from a national grant, and it was implemented to visualize the heart area when the patient is under stress condition. The two panels geometry was also implemented for this system, but using pixelated crystals, therefore improving the detector time resolution and allowing to use time of flight (TOF) reconstruction algorithms. Two panels were mounted and tested with both simulation and experimental data with good results. Furthermore, the patient motion was registered applying movement correction techniques with the help of an external optical camera device and ARUCO markers. These algorithms were tested showing a good performance. The last device that we worked within this PhD thesis was designed to optimize the classical ring PET configuration as much as possible. To do so, the gaps between the detector modules in a small animal PET were eliminated by building a single detector with a cylindrical scintillator shape. The goal is to improve the sensitivity, given that there are no event losses in the gaps and to also boost the spatial resolution since there are not edges. Two prototypes were tested with simulations, and experimentally validated as well. The first of them was built with planar outer faces whereas the second was fully cylindrical. In both designs some effects originated from the detector curvature were observed and successfully corrected during the calibration. / This thesis was supported by a FPI grant under 2017-08582 reference in the PhD program: “Programa de Doctorado en Tecnologías para la Salud y el Bienestar” belonging to the Polytechnic University of Valencia. The grant was supported by the “Consejo Superior de Investigaciones Científicas” together with the “Agencia Estatal de Investigación” and the “Fondo Social Europeo”. / Cañizares Ledo, G. (2022). Characterization of Dedicated PET Equipment with Non-Conventional Geometry [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/184977
104

Estudio anatómico, ecográfico, tomográfico e imagen por resonancia magnética de la articulación temporomandibular del caballo / Anatomy ultrasonography, computed tomography and magnetic resonance imaging of teh equine temporomandibula joint

Rodríguez Vizcaíno, María Jesús 12 December 2008 (has links)
La articulación temporomandibular (ATM) del caballo es una región anatómica compleja que tiene una gran influencia en el rendimiento deportivo. La ecografía, la tomografía computerizada (TC) y la imagen por resonancia magnética (IRM) permiten evaluar los componentes articulares evitando la superposición de estructuras adyacentes como ocurre en radiografía. Los estudios acerca del uso de dichas técnicas en el diagnóstico de la ATM equina son escasos. El objetivo de estas Tesis fue estudiar detalladamente la anatomía, la anatomía ecográfica, tomográfica y por resonancia magnética de la ATM equina. La ATM presenta un aporte vascular periférico propio y una relación íntima con estructuras vitales como el oído medio y el nervio mandibular, explicando así muchos síntomas inespecíficos descritos en patologías temporomandibulares. El estudio ecográfico de la ATM precisa de tres abordajes, lateral, caudal y rostral mediante los que se evalúa el aspecto más lateral de la articulación. La TC es el método de elección para estudiar los componentes óseos articulares y estructuras adyacentes, siendo los planos más informativos el sagital y el transversal. Mediante la IRM (secuencias SE T1, T2* y DP supresión grasa) se evalúan de forma simultánea los componentes óseos y tejidos blandos de la ATM, obteniéndose mayor información en los planos sagital y transversal oblicuos. / The equine temporomandibular joint (TMJ) is a complex anatomical region which has a great influence on the horse's performance. Ultrasonography (US), computed tomography (CT) and magnetic resonance imaging allow the assessment of the articular components avoiding the superimposition of the adjacent osseous structures as occur on the radiographic views. Reports concerning the use of these techniques in the equine TMJ are limited. The aim of this Thesis was to study in detail the anatomy and the ultrasonographic, CT and MRI anatomy of the equine TMJ. The equine TMJ has its own peripheral vascular supply and is related to vital structures such as the middle ear and mandibular nerve. These relationships can explain many of the non-specific symptoms described in TMJ pathologies. For TMJ ultrasonography, 3 approaches, lateral, caudal and rostral, are used to evaluate the lateral aspect of the joint. CT is the method of choice to study TMJ bony components and adjacent structures, being the sagittal and transverse planes the most informative planes. By MRI (SE T1, T2* and PD fat-suppression sequences), bone and soft tissues of the TMJ are assessed simultaneously, obtaining more information from the oblique sagittal and transverse planes.
105

Comparación de imágenes entre secuencia convencional y secuencia de difusión en la resonancia magnética nuclear del accidente cerebrovascular isquémico agudo. Centro Diagnóstico Osteoperú, Lima-2017

Pitot Tomateo, Luis Alfredo January 2018 (has links)
Publicación a texto completo no autorizada por el autor / Compara las imágenes entre la secuencia convencional y la secuencia de difusión en la resonancia magnética nuclear del accidente cerebrovascular isquémico agudo en el Centro Diagnóstico Osteoperú en Lima en el año 2017. Es un estudio cuantitativo, observacional, con diseño descriptivo-comparativo, transversal y retrospectivo cuya muestra está constituida por 78 estudios de resonancia magnética nuclear cerebral en pacientes con accidente cerebrovascular isquémico agudo atendidos en el Centro Diagnóstico Osteoperú en Lima en el año 2017, seleccionados mediante un registro censal, teniendo en cuenta los criterios de inclusión y exclusión. La técnica utilizada es el análisis documental y el instrumento una ficha de recolección de datos. Para el análisis descriptivo de las variables cualitativas se estiman frecuencias absolutas y relativas (porcentajes). / Tesis
106

Asociación de la presencia de alteraciones morfológicas condilares de la articulación temporomandibular con los grados de facetas de desgaste dentario evaluados en tomografías / Association between presence of mandibular condyle osseous changes and tooth wear: a CBCT study

Cavero Garcia, Aracelli Paola, Gutierrez Draxl, Mateo 15 March 2021 (has links)
Objetivo: Evaluar la asociación de la presencia de alteraciones morfológicas condilares de la articulación temporomandibular con los grados de facetas de desgaste dentario evaluados en tomografías. Materiales y métodos: Un total de 208 tomografías fueron analizadas en este estudio. Se evaluaron las alteraciones morfológicas condilares (osteofito, aplanamiento, erosión, esclerosis, pseudoquiste), así como los grados de facetas de desgaste dentario del 0 al 4 según Hansson y Nilner. Además, se identificaron otras variables como la presencia de mordida abierta, overjet aumentado, overbite aumentado, entre otros. Se utilizó la prueba de Test Exacto de Fisher para evaluar la asociación de las variables y, para el cálculo de las razones de prevalencia crudas y ajustadas se utilizó la regresión de Poisson con varianza robusta.  Resultados: No se encontró asociación entre los grados de faceta de desgaste dentario y la presencia de alteraciones morfológicas condilares. Sin embargo, se observó que a mayor grado de faceta de desgaste hay un incremento en la prevalencia de alteraciones morfológicas. Así, aquellos con Grado 3 de desgaste poseían 36% más probabilidad de presentar alteraciones morfológicas condilares que aquellos con faceta de desgaste Grado 0 (p=0.004).  Conclusiones: Se observó que la presencia de alteraciones morfológicas condilares está relacionada al Grado 3 de desgaste dentario y al sexo femenino. Sin embargo, se sugiere enfocar nuevas investigaciones en la evaluación de Grados 2, 3 y 4 para corroborar lo encontrado. / Objective: The aim of the study was to determine association between the presence of mandibular condyle osseous changes and tooth wear facets evaluated in cone beam computed tomography. Materials and methods: A total of 208 tomography were analyzed. Mandibular condyle osseous changes (osteophyte, flattening, erosion, sclerosis, pseudocyst) were evaluated and tooth wear was assessed between grades 0 to 4 according to Hansson & Nilner, Other variables such as the presence of open bite, increased overjet, increased overbite, among others, were identified. Fisher’s Exact test was used to evaluate association between variables. The crude and adjusted prevalence ratios were performed using the Poisson regression with robust variance. Results: No association was found between tooth wear and presence of mandibular condyle osseous changes. However, these increased as more dental structures got compromised. Thus, individuals with Grade 3 wear were 36% more likely to have mandibular condyle osseous changes than those with Grade 0 wear facet (p = 0.004). Conclusions: Presence of condylar osseous changes of the temporomandibular joint was associated with Grade 3 wear facet and gender. However, further examination of moderate to severe tooth wear is recommended to support the established association. / Tesis
107

Análisis de la capa de fibras nerviosas de la retina con OCT en niños con migraña

Fernández Montalvo, Lorena 18 September 2017 (has links)
Objetivo: Encontrar posibles efectos estructurales de la migraña en la capa de fibras nerviosas de la retina (CFNR) en áreas peripapilares mediante tomografía de coherencia óptica (OCT) en niños y adolescentes.Material y métodos: Se evaluaron a 50 niños consecutivos con migraña, 25 con aura visual y 25 sin aura, y un grupo control de 25 niños sanos. La edad media de los pacientes y del grupo control fue de 9.5 ± 2.4 and 9.9 ± 2.6 años respectivamente, y la duración media de la migraña en pacientes con aura (MA) y sin aura (MsA) fue de MA = 1.9 ± 1.2 años y MsA = 2.4 ± 1.1 años respectivamente. Se utilizó la tomografía de coherencia óptica de dominio espectral para medir y comprar el grosor de la CFNR entre niños con migraña y niños sanos. Resultados: El grosor medio de la CFNR (OD, ojo derecho: P=0.013; OI, ojo izquierdo: P= 0.019), y de los cuadrantes nasal (OD: P< 0.001; OI: P< 0.001), y el temporal (OD: P< 0.001; OI: P< 0.001) estaba significativamente más adelgazado en los ojos de los pacientes migrañosos en comparación con los del grupo control. Otros parámetros no mostraron diferencias estadísticamente signficativas entre el grupo de migraña y el control. Conclusiones: La CFNR media y los cuadrantes nasal y temporal en pacientes pediátricos con migraña se encuentra reducida de forma estadísticamente significativa respecto a sujetos normales.
108

Grosor de tejidos a nivel del paladar en diferentes tipos faciales de pacientes atendidos en un centro radiográfico de Chiclayo-2023

Neira Garcia, Daniel Paolo January 2024 (has links)
Introducción: El propósito del estudio fue evaluar el grosor medio del paladar según zona anatómica y tipo facial en pacientes atendidos en un centro de diagnóstico por imágenes de Chiclayo, 2023. Materiales y métodos: El estudio se llevó a cabo sobre los registros tomográficos y fotografías de 140 pacientes. Se estableció un área para medir el grosor de los tejidos a nivel del paladar, las mediciones se dieron a 0, 5, 10, 15, 20, 25mm posterior al agujero nasopalatino. Resultados: El tipo braquifacial obtuvo el menor y mayor grosor medio del paladar a los 0mm y 5mm respectivamente, el tipo mesofacial obtuvo el menor y mayor grosor medio a los 0mm y 5mm respectivamente, el tipo dolicofacial obtuvo el menor y mayor grosor medio a los 15mm y 5mm respectivamente. Se demostró significancia estadística entre la edad y el grosor del tejido blando a los 25 mm (p=0.036). Se demostró significancia estadística entre el sexo y el grosor del tejido óseo a los 5 y 10 mm (p=0.046) y el tejido blando a los 20 y 25mm (p=0.036). Conclusiones: Existe correlación significativa en el tipo dolicofacial a los 15 y 20 mm, en el tipo braquifacial y mesofacial a los 25 mm; independientemente del tipo facial se demostró significancia estadística entre el sexo y el tejido óseo a los 5 y 10 mm y de tejido blando a los 20 y 25 mm; entre la edad y el tejido blando a los 25mm. / Introduction: The purpose of the study is to evaluate the average thickness of the palate according to anatomical area and facial type in patients treated at a diagnostic imaging center in Chiclayo, 2023. Materials and methods: The study was carried out on tomographic records and photographs of 140 patients. An area was established to measure the thickness of the tissues at the level of the palate, the measurements were given at 0, 5, 10, 15, 20, 25mm posterior to the nasopalatine foramen. Results: The brachyfacial type obtained the smallest and greatest average thickness of the palate at 0mm and 5mm respectively, the mesofacial type obtained the smallest and greatest average thickness at 0mm and 5mm respectively, the dolichofacial type obtained the smallest and greatest average thickness at 15mm and 5mm respectively. Statistical significance was demonstrated between age and soft tissue thickness at 25 mm (p=0.036). Statistical significance was demonstrated between sex and the thickness of the bone tissue at 5 and 10 mm (p=0.046) and the soft tissue at 20 and 25mm (p=0.036). Conclusions: There is a significant correlation in the dolichofacial type at 15 and 20 mm, in the brachyfacial and mesofacial type at 25 mm; Regardless of facial type, statistical significance was demonstrated between sex and bone tissue at 5 and 10 mm and soft tissue at 20 and 25 mm; between age and soft tissue at 25mm.
109

Diseño, síntesis y caracterización de compuestos de coordinación de cobre (ii) derivados de estilbeno, afines a las placas amiloides, con potencial como agentes de radiodiagnóstico de Alzheimer

Uehara Oshiro, Diego Adrián 25 November 2022 (has links)
En el presente trabajo se presenta la síntesis y caracterización de tres nuevos complejos de coordinación de cobre de fórmula general Cu(L)1-3 con los ligandos tipo base de Schiff derivados del estilbeno. Estos complejos podrían ser considerados como potenciales agentes de radioimagen para el diagnóstico del Alzheimer por tomografía de emisión de positrones (PET), debido a la posible afinidad de los ligandos por las placas amiloides β. El radioisótopo de 64Cu es de interés en el desarrollo de radiofármacos empleados en PET, ya que presenta un tiempo de vida media y una energía de decaimiento β+ óptimos en comparación con otros radionúcleos. Asimismo, este ion metálico suele incorporarse de forma sencilla, rápida, y eficiente en radiofármacos. En ese sentido, este trabajo consiste en la síntesis, purificación y caracterización de complejos de 63Cu para sintetizar en un futuro los complejos de 64Cu y probar su actividad biológica en agregados fibrilares amiloides β. Los complejos de cobre (II) fueron sintetizados por el complejamiento entre el ion Cu(II) y los ligandos derivados del estilbeno. Estos ligandos se obtuvieron por una serie de pasos sintéticos que se inició con un acoplamiento de Heck entre un bromuro de arilo y un vinil benceno, el cual fue generado in situ por la deshidratación selectiva de un alcohol secundario. Posteriormente, se realizó la condensación con la amina para la obtención del ligando base de Schiff. Los ligandos derivados del estilbeno y los complejos de cobre fueron caracterizados por técnicas espectroscópicas de infrarrojo (FTIR), espectroscopía ultravioleta visible (UV-VIS), resonancia magnética nuclear (RMN), espectrometría de masas de alta resolución (HRMS) y difracción de rayos X (XRD).
110

Estudio e implementación de algoritmos digitales para la mejora de la resolución temporal en sistemas de tomografía por emisión de positrones

Monzó Ferrer, José María 26 September 2012 (has links)
La Tomografía por emisión de positrones (PET, Positron Emission Tomography) es una técnica de diagnóstico médico que se encarga de mostrar imágenes de la distribución de radioisótopos dentro del cuerpo, permitiendo de esta forma observar procesos metabólicos que ocurren en su interior. Los sistemas PET se encargan de detectar pares de rayos gamma de 511KeV cada uno generados tras la aniquilación de un positrón con un electrón. De cada rayo gamma detectado, obtenemos su energía, la posición en la que el rayo es detectado y el tiempo exacto en el que el evento ha sido detectado. Denominamos tiempo de coincidencia a la diferencia de tiempos entre dos eventos. La resolución temporal de un sistema vendrá determinada por el error temporal cometido en la medida del tiempo de coincidencia. Una mejora en la resolución temporal implica una reducción del ruido de las imágenes generadas en el sistema PET. Tradicionalmente, las técnicas para la extracción del tiempo de un evento recibido han sido implementadas analógicamente. Estas técnicas permiten alcanzar una resolución temporal muy elevada. Sin embargo, la electrónica usada en las técnicas analógicas está muy adaptada a un detector específico, es compleja y poco configurable. La búsqueda de coincidencias en sistemas con muchos detectores que hacen uso de técnicas analógicas se vuelve un gran problema, pues hace necesario un incremento de la complejidad de la electrónica muchas veces inabordable. Existe una tendencia actual a reducir la electrónica analógica de los sistemas PET sustituyéndola por electrónica digital mediante una temprana digitalización de las señales de los detectores. Por tanto, deben proponerse y estudiarse algoritmos digitales para la extracción de una marca temporal de los eventos detectados. Por el momento, las técnicas digitales actuales no alcanzan las resoluciones temporales de las técnicas analógicas. El presente estudio se enmarca dentro del ámbito de los discriminadores de tiempo digitales. En el grupo de investigación, se dispone de un setup de medida con dos detectores de rayos gamma cuyas señales de salida se procesan en un front-end analógico. Las señales resultantes del front-end analógico son digitalizadas en un sistema de adquisición donde se procesan digitalmente. La búsqueda de una mejora en la resolución temporal del sistema y el hecho de que el procesado digital, todavía poco aplicado a los sistemas PET, puede proporcionar grandes mejoras en dicha resolución fueron la motivación inicial de la presente investigación. Durante la tesis, se proponen diferentes algoritmos digitales para la extracción de la información temporal de los pulsos recibidos. En un primer paso, se realiza un estado del arte a partir del cual se aportan diferentes posibles soluciones al problema. Los algoritmos propuestos están basados en bloques de procesado digital que pueden combinarse entre ellos. Estos algoritmos extraen la información temporal de las señales procesadas haciendo uso de versiones digitales adaptadas y configurables de discriminadores analógicos clásicos junto con bloques digitales que no poseen su análogo analógico. Uno de estos bloques digitales implementado se encarga de aumentar la frecuencia de muestreo mediante interpolación por filtro paso bajo, interpolando por factores x2 y x3 la señal de entrada. Entre los algoritmos analizados, el estudio propone nuevos discriminadores que se basan en hacer un cálculo digital de la carga de los pulsos recibidos, interpolados o no interpolados, obteniendo resultados mejores que con las configuraciones clásicas que trabajan con el pulso directamente adquirido y sin procesar. Para realizar el estudio del comportamiento de los discriminadores evaluados, se desarrolla una simulación que permite validar todo el sistema PET desde los detectores, generando pulsos lo más realistas posibles; la electrónica analógica, simulada mediante simuladores de tipo SPICE; y a nivel digital, estudiando el comportamiento de los algoritmos propuestos. Los algoritmos son simulados con distintas configuraciones, condiciones de jitter de reloj y ruido. Por último, todos los algoritmos propuestos son programados en la FPGA del sistema con arquitecturas que trabajan en tiempo real a medida que se vayan detectando eventos. Se definen y llevan a cabo una serie de experimentos que validan en condiciones reales en el setup de medida el funcionamiento de los discriminadores. Las medidas también permiten validar la simulación desarrollada. De esta forma, se dispone de una plataforma de test para futuras mejoras. Como conclusión final, en el trabajo se demuestra como un adecuado procesado digital de la señal permite mejorar la resolución temporal del sistema de forma considerable. El procesado digital, de gran flexibilidad frente al analógico, junto con el incremento de la velocidad de los dispositivos digitales programables y el incremento de la frecuencia de muestreo y de la integración de los convertidores analógicos-digitales (ADCs, "Analog to digital converters") hacen prever un aumento en el número de sistemas PET con estas características en un futuro no lejano y, por tanto, las soluciones investigadas en trabajos como el aquí presentado proporcionarán un aporte básico y necesario para futuros desarrollos. / Monzó Ferrer, JM. (2012). Estudio e implementación de algoritmos digitales para la mejora de la resolución temporal en sistemas de tomografía por emisión de positrones [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/17226

Page generated in 0.0412 seconds