• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 662
  • 22
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 707
  • 361
  • 97
  • 88
  • 75
  • 72
  • 64
  • 56
  • 50
  • 46
  • 41
  • 41
  • 39
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Efeito do ultrassom na eliminação de micro-oganismos e endotoxinas em dentes com infecção endodôntica primária /

Orozco, Esteban Isai Flores. January 2016 (has links)
Orientador: Marcia Carneiro Valera / Banca: Carlos Henrique Ribeiro Camargo / Banca: Renato Miotto Palo / Resumo: Os objetivos do presente estudo foram: a) Verificar a carga microbiana e quantificar endotoxinas presentes nos canais radiculares de dentes com infecção endodôntica primária; b) Comparar a efetividade antibacteriana e sobre endotoxinas do preparo biomecânico com dois métodos de irrigação final: com ou sem irrigação ultrassônica passiva; c) Correlacionar sinais e sintomas com a microbiota presente e complexos bacterianos; d) Relacionar níveis de endotoxinas e carga microbiana com sinais e sintomas clinicos. Foram selecionados para o estudo 20 dentes uniradiculares, que apresentavam infecção endodôntica primária e lesão periapical, sendo estes submetidos a TCFC. Os canais foram preparados com sistema reciprocante e irrigação com NaOCl 2.5%, seguido de dois protocolos de irrigação final: com e sem uso de ultrassom. Todos os canais foram preenchidos com MIC com hidróxido de cálcio + soro fisiológico e após 14 dias foram obturados com cones de guta-percha e cimento AH Plus. Foram realizadas coletas do conteúdo do canal, logo após a abertura coronária (1ª Coleta); após PBM (2ª Coleta) e após limpeza final dos canais com NaOCl seguido de EDTA por 5 min (grupo sem PUI); ou irrigação com NaOCl + PUI e EDTA + PUI (3ª Coleta) (grupo com PUI) . Foram avaliados sinais/sintomas clínicos previo ao tratamento.O conteúdo das coletas foi analisado a partir de sondas de DNA pelo método de hibridização DNA-DNA checkerboard e foi realizado teste de avaliação da atividade antimicrobiana por cultu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : the objetive of this study were: a) to check the microbial load and to quantify endotoxin present in the root canals of teeth with primary endodontic infection; b) to compare the effectiveness of bacteria and endotoxin reduction of the biomechanical preparation with final irrigation methods: with or without passive ultrasonic irrigation (PUI); c) to correlate signs and symptoms with the present microbiota and bacterial complexes; d) to relate endotoxin and microbial load levels with signs and symptoms before biomechanical preparation. Twenty single-root teeth were selected for the study, presenting primary endodontic infections and periapical lesion, which underwent CBCT. The canals were prepared with reciprocating system and irrigation with 2.5% NaOCl, followed by two final irrigation protocols: with and without ultrasound. All canals were filled with MIC with calcium hydroxide + saline and after 14 days were filled with gutta percha and AH Plus. Samples from the content of canal were harvested, after coronal opening (1st Sample); after PBM (2nd Sample) and after final cleaning of the canals with NaOCl followed by EDTA for 5 min (group without PUI); or irrigation with NaOCl + PUI and EDTA + PUI (3rd Sample) (group with PUI). The contents of the samples were analyzed from DNA probes by the DNA-DNA checkerboard hybridization method and a test was performed to evaluate the antimicrobial activity by microbiological culture. In addition, quantification of endotoxins by Limulus Amebocyte Lysate (LAL) was performed. The canal volumetry was assessed through the CBCT using Nemotec® software. The results were submitted to statistical analysis by Mann Whitney and repeated measures two-way ANOVA (5%). Value of p <0.05 was considered statistically significant. There was an association between pain at percussion and main orange and peripheral orange complexes...(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
162

Inspeção de materiais compósitos utilizando ondas acústicas guiadas /

Granja, Silvio Cesar Garcia. January 2015 (has links)
Orientador: Ricardo Toquio Higuti / Co-orientador: Luis Elvira Segura / Banca: Cláudio Kitano / Banca: Vicente Lopes Júnior / Banca: Julio Cesar Adamowski / Banca: João Marcos Salvi Sakamoto / Resumo: Neste trabalho de tese, faz-se um estudo sobre inspeção não destrutiva por ultrassom de placas planas de compósito têxtil de trama simples. Para isso foram realizadas análises para obter os parâmetros elásticos que caracterizam cada lâmina do compósito têxtil. Foi feita uma revisão de métodos analíticos para a determinação das equações características dos modos de propaga- ção e dos métodos numéricos para obtenção de soluções das curvas de dispersão em placas de material anisotrópico. São apresentadas algumas descrições de compósitos têxteis, mais especi- ficamente os de trama simples 2D ortogonal de fibra de carbono-epóxi. Curvas de dispersão de velocidade de fase, velocidade de grupo, ângulo de desvio e fator de focalização foram obtidas por meio de simulação numérica para os modos simétricos e antissimétricos de propagação das ondas, no modelo de um laminado multidirecional constituído de nove camadas com empilha- mento [0/+90/+45/+90/0/+90/-45/+90/0]. Cada camada é feita de fibras carbono no formato de tecido de trama simples ortogonal 2D (T300) em uma matriz de epóxi (F155). Usa-se o modelo de camadas múltiplas para descrevê-lo considerando condições de continuidade nas interfaces entre as camadas, usando o método de matriz de transferência para determinar os modos de propagação em forma de velocidades de fase como função da frequência e direção de propagação da onda no laminado. Abordagens experimentais foram realizadas para a va- lidação das previsões teóricas. Foram utilizados dois transdutores de banda larga de 5 MHz acoplados a prismas com ângulos diferentes para seleção de velocidades, operando em sistema de transmissão-recepção, assim como varreduras das placas com dois tipos de vibrômetros la- ser. Os resultados foram analisados comparando-se as velocidades de fase, as curvas de onda e os padrões de focalização... / Abstract: In this thesis, a detailed study of ultrasonic non-destructive evaluation in plain woven fabric composite plates is performed. A review of analytical and experimental methods for the de- termination of the characteristic equations of the propagation modes and methods for obtain- ing numerical solutions of the elastic constants of the composite and dispersion curves of anisotropic material plates were performed. Some descriptions of textile composites are pre- sented, specifically the 2D orthogonal plain woven fabric carbon-fiber epoxy. Phase and group velocity dispersion curves, skew angle and focusing factor were obtained by numerical simula- tion for the symmetric and antisimetric modes of wave propagation using a multi-layer model with [0/90/45/90/0/90/-45/90/0]. Each layer is made of carbon fibers in the 2D orthogonal plain weave fabric format (T300) in an epoxy matrix (F155). The transfer matrix method was used to model the multilayer composite, resulting in the determination of the propagation modes from their phase/group velocities as a function of frequency and propagation direction in the lami- nate. Experimental approaches were made to validate the theoretical predictions. Two broad- band transducers coupled to acrylic wedges were used with different angles for speed selection, operating in transmission-reception system; scans of the plates with two types of laser vibrom- eters were also used to measure wave propagation. The results were analyzed by comparing the phase velocities, the wave curves and elastic focusing patterns of the A0 and S0 modes, showing agreement with the prediction of the multilayer analytical model. The inspection of two plates was conducted with linear arrays of piezoelectric transducers and synthetic aperture imaging techniques. The ultrasonic images of textile composite plates take into account the propagation mode, the dispersion compensation of the wave packet and ... / Doutor
163

Efeitos da aplicação do ultra-som de baixa intensidade na retração de caninos

Zavaglia Neto, Regynaldo [UNESP] 10 May 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-05-10Bitstream added on 2014-06-13T20:57:11Z : No. of bitstreams: 1 zavaglia_neto_r_me_arafo.pdf: 607892 bytes, checksum: ce4a2b46c52e9f11330e30627f4df2bc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho busca avaliar na movimentação ortodôntica os efeitos de uma tecnologia chamada Ultra-Som de Baixa Intensidade, que produz alterações à nível celular nos tecidos aplicados, permitindo maximizar as respostas da remodelação óssea. As comprovações em animais já indicam a possibilidade de potencializar a movimentação ortodôntica, fazendo a aplicação durante 20 minutos diários. Para a avaliação com seres humanos, dez pacientes Classe II divisão 1 que necessitavam de extração dos primeiros pré-molares superiores foram selecionados. Após a extração e sequência dos arcos de alinhamento e nivelamento, foi realizada a retração parcial dos caninos superiores com molas de NiTi com força de 150 gramas. Neste dia os pacientes foram radiografados para a obtenção das telerradiografias 45º iniciais do lado direito e esquerdo. Após oito semanas de aplicação diária do Ultra-Som no lado sorteado, os pacientes foram novamente radiografados e obtivemos as telerradiografias 45º finais do lado direito e esquerdo. A partir disso, cefalogramas das telerradiografias iniciais e finais foram gerados e avaliados em um programa de cefalometria computadorizado. Tivemos variáveis que avaliaram angulação, deslocamento horizontal e vertical do lado que recebeu ultra-som (LUS) e do lado controle (LC). Após análise estatística, onde testes t de Student foram aplicados, percebemos a tendência dos caninos que receberam a aplicação do ultra-som de baixa intensidade, movimentar mais que os do lado controle. Outro aspecto foi ótimo controle de ancoragem que conseguimos com a força de 150 gramas de força e do uso da barra palatina. / The aim of this research is to evaluate the effects in orthodontic movement of the Low Intensity Ultrasond technology, which produces alterations on cellular level in the applied tissues, allowing the maximization of the bone remodeling response. Experimental studies in animals have already indicated the possibility to potencialize the orthodontic movement with twenty minutes daily ultrasound application. In order to evaluate its effect on human beings, ten Class II division 1 patients with the need of upper first premolars extraction were selected. After the upper premolars extraction and leveling and alignment of the archs, an upper canine partial retraction was obtained with NiTi coil spring delivering a force of 150g. Immediately after the installation of the springs, right and left 45º cephalometric radiographs were taken. After 8 weeks of daily application of ultrasound on the selected side, the final right and left 45º cephalometric radiographs were obtained. Then, initial and final cephalograms were traced and evaluated by a cephalometric software. We evaluated angulation and horizontal and vertical dislocation variables of either the ultrasound side (USS) or the control side (CS). After statistic analysis in a wich a t Student test was performed, we observed the tendency of increased movement of the experimental canines when compared to the control ones. Another important aspect was the good anchorage control obtained by the transpalatal arch use when a 150g force was applied.
164

Ultra-sonografia pré-cirúrgica da lente e do segmento posterior de cães portadores de catarata

Rodrigues Junior, Emílio Fernandes [UNESP] 25 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-25Bitstream added on 2014-06-13T19:09:49Z : No. of bitstreams: 1 rodriguesjunior_ef_me_jabo.pdf: 359523 bytes, checksum: 2c23cc1e2be735e8fdf242ca84017e13 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A ultra-sonografia do segmento posterior do bulbo do olho é procedimento necessário para a avaliação de cães com catarata, que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Foram avaliados 30 cães (56 olhos), machos ou fêmeas, com idade entre 3 a 14 anos, portadores de diferentes tipos de catarata, em estágios variados de evolução. Realizou-se a ecografia nos modos A e B para o exame da lente e do segmento posterior. Clinicamente, diagnosticou-se catarata madura em 41 olhos (73,21%), catarata imatura em 14 olhos (25%) e catarata hipermatura em apenas um caso (1,78%). Verificou-se, ainda, catarata cortical anterior, posterior e nuclear em 12 olhos (21,42%), catarata cortical anterior, posterior, nuclear e capsular posterior em 23 olhos (41,07%), catarata cortical anterior, posterior e capsular posterior em um olho (1,78%), catarata cortical anterior e nuclear em um olho (1,78%), catarata cortical anterior, nuclear e capsular posterior em cinco olhos (8,92%) e catarata cortical anterior em sete dos olhos (12,5%). Diferentes alterações ultra-sonográficas foram observadas no segmento posterior em 26 dos 56 olhos avaliados (46,42%), incluindo alterações como degeneração vítrea (12 olhos, 21,42%), exsudato ou hemorragia (sete olhos, 12,5%), persistência de artéria hialóide (quatro olhos, 7,14%) e sub-luxação do cristalino (três olhos, 5,35%). A partir dos resultados obtidos, reitera-se a relevância em se realizar a ultra-sonografia em pacientes da espécie canina candidatos à facectomia, dado que alterações do segmento posterior do bulbo do olho são de difícil identificação, quando a lente encontra-se opacificada. / The ultrasound inspection of bulb posterior segment of eyes is a necessary procedure for the evaluation of dogs with cataracts, which will be submitted to the surgery extraction, since the ophthalmoscopy is not feasible when there is opacification of the lens, specially in mature cataracts. Thirty dogs were evaluated (56 eyes), males or females, from 3 to 14 years, affected with different types of cataracts in various developing stages. There was an ultrasound A and B in order to examine the lens and the posterior segment. The dogs were clinically diagnosed to the presence of cataract, demonstrating that 41 eyes (73.21%) was mature, 14 eyes (25%) imature and only one case (1.78%) hypermature. It was verified that 12 dogs eyes (21.42%) showed earlier cortical cataracts, posterior and nuclear, 23 eyes (41.07%) capsular earlier cortical cataracts, posterior and nuclear, one eye (1.78%) capsular earlier cortical cataracts and posterior capsular in cortical cataracts and nuclear up in one eye (1.78%), cortical cataracts earlier, nuclear and capsular in five eyes (8.92%) and cortical cataracts in seven previous eyes (12.5%). Changes in ultrasound evaluation were observed in the posterior segment in 26 of the 56 eyes evaluated (46.42%), including changes as vitreous degeneration 12 eyes, (21.42%), exudate or bleeding 7 eyes (12.5%), continuing artery hyaloid 4 eyes (7.14%) and sub dislocation of the lens 3 eyes (5.35%). From the results reaffirms the importance to take place in the ultrasound patients in the species canine candidates for extraction, since changes in the posterior segment of the bulb of the eyes are difficult to identify, when the lens is opacified.
165

Desempenho e características quantitativas in vivo e da carcaça de cordeiros recebendo dietas contendo silagem de milho ou cana-de-açúcar em dois níveis de concentrado /

Moreno, Greicy Mitzi Bezerra. January 2008 (has links)
Orientador: Américo Garcia da Silva Sobrinho / Banca: Jane Maria Bertocco Ezequiel / Banca: Lúcia Maria Zeoula / Resumo: Utilizou-se 32 cordeiros Ile de France, não castrados, alimentados com dietas contendo silagem de milho ou cana-de-açúcar em duas relações volumoso:concentrado, 60:40 ou 40:60. Os animais permaneceram confinados individualmente com controle do alimento fornecido e sobras, e foram abatidos aos 32 kg de peso corporal. O ganho de peso foi maior nos animais alimentados com silagem de milho (294,6 g/dia) e na relação 40:60 (314,3 g/dia). Cordeiros alimentados com silagem de milho apresentaram maior consumo de todos os nutrientes digestíveis, exceto de proteína bruta (PB) (162,00 g/dia) e carboidratos não fibrosos (471,42 g/dia). Houve maiores coeficientes de digestibilidade da matéria seca (78,91%), PB (81,30%) e energia bruta (78,77%) nos animais alimentados com cana-de-açúcar. As características in vivo e da carcaça dos cordeiros não foram afetadas (p>0,05) pela relação volumoso:concentrado e tipo de volumoso, exceto a condição corporal, que foi maior (3,85) nos cordeiros alimentados com 40% de volumoso. O conteúdo do trato gastrintestinal foi maior nos cordeiros alimentados com cana-de-açúcar (15,17%) e na relação 60:40 (14,55%). Os rendimentos de carcaça quente (48,6%) e comercial (47,3%) foram menores nos cordeiros que receberam cana-de-açúcar. Houve menor rendimento de lombo nos cordeiros alimentados com cana-de-açúcar (9,1%) e na relação 60:40 (9,2%)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Thirty-two male Ile de France lambs, non castrated, were submitted to diets containing corn silage or sugar cane with two roughage:concentrate ratio, 60:40 or 40:60. The lambs were confined individually with control of the food supplied and leftovers and were slaughtered at 32 kg of body weight. The daily weight gain were greater for lambs fed up with corn silage (294.6 g/day) and for the 40:60 roughage:concentrate ratio (314.3 g/day). Lambs fed up with corn silage showed greater intake for all digestible nutrients, except for crude protein (162.0 g/day) and non fiber carbohydrate (471.42 g/day). The digestibility coefficients of dry matter (78.91%), crude protein (81.30%) and crude energy (78.77%) were greater in lambs that received sugar cane. The in vivo and carcasses traits were not affected (p>0.05) by diets, except for the corporal condition, that was greater (3.85) in lambs that received 40% of roughage. The contain of gastrointestinal tract was greater in lambs fed up with sugar cane (15.17%) and 60% of roughage (14.55%). The warm (48.6%) and commercial (47.3%) carcass yields were smaller in lambs that received sugar cane, 48.6 and 47.3%. There was smaller loin yield in the lambs fed up with sugar cane (9.1%) and 60% of roughage (9.2%)...(Complete abstract click electronic access below) / Mestre
166

Ultrassonografia modo B de alta resolução modo Doppler e uso de contraste de microbolhas na avaliação testicular de gatos domésticos /

Brito, Marina Botelho Soares de. January 2015 (has links)
Orientador: Marcus Antonio Rossi Feliciano / Coorientador: Wilter Ricardo Russiano Vicente / Banca: Pedro Paulo Maia Teixeira / Banca: Anelise Carvalho Nepomuceno / Resumo: As pesquisas envolvendo a reprodução de gatos domésticos comumente baseiam-se em análise macroscópica e andrológica do sistema reprodutor desses animais, não havendo nenhum estudo até o momento sobre a avaliação ultrassonográfica dos testículos nesta espécie. Sendo assim, este estudo prospectivo visou realizar a varredura ultrassonográfica dos testículos de 45 gatos adultos domésticos, utilizando as técnicas Modo B, Doppler e Ultrassonografia por Contraste com Microbolhas. Os resultados obtidos ao exame ultrassonográfico modo B demonstraram as estruturas testiculares com ecotextura homogênea e com ecogenicidade dentro da normalidade (semelhante à ecogenicidade do tecido esplênico), com presença de linha mediastinal evidente. Ao Doppler colorido testicular, foi possível verificar artéria testicular com padrão de ondas arterial e monofásico, em região de cordão espermático. Utilizando o Doppler Espectral, obtiveram-se os índices vasculares dos testículos direito e esquerdo, respectivamente: VS = 6.23 cm/s, VD = 2.77 cm/s e IR = 0.53; VS = 6.73 cm/s, VD = 2.8 cm/s e IR = 0.54. A avaliação ultrassonográfica contrastada por microbolhas não resultou em efeitos colaterais aos animais, apresentando-se de aplicação confiável e gerando imagens de qualidade. O contraste preencheu as estruturas vasculares subcapsulares, com moderado realce homogêneo do parênquima, além de rápida redução da ecogenicidade após o pico de realce. Os valores de tempo para o contraste de microbolhas, considerando tempo de entrada, pico de realce e tempo de saída para os testículos direito e esquerdo foram, respectivamente: tempo de entrada = 10.76 s, pico de realce = 21.50 s e pico de saída = 81.81; tempo de entrada = 8.78 s, pico de realce = 21.62 s e tempo de saída = 75.36. Esses exames foram facilmente aplicados em gatos domésticos e devem ser utilizados como técnicas auxiliares no diagnóstico de anormalidades testiculares... / Abstract: Research involving breeding of domestic cats are commonly based on macroscopic and andrologic analysis, there is no study to date with sonographic evaluation of domestic cats testicle. Thus, this study aimed to perform the ultrasound scan of 45 adult domestic cats testicles, using the techniques of B mode, Triplex Doppler ultrasound and contrast-enhanced. The results showed homogeneous testicles, with normal echogenicity and echotexture, with evident mediastinal line. Testicular artery was observed in the spermatic cord with tortuous patter and showed monophasic-patterned waves and low vascular resistance and with systolic peak evident. Values of indices vascular were as follows: SV = 6.73 cm/s, DV = 2.8 cm/s and RI = 0.54 for left testicles; and SV = 6.23 cm/s, DV = 2.77 cm/s and RI = 0.53 for right testicles. The contrast-enhanced resulted in no side effects, being reliable and generating quality images. Contrast filled the subcapsular vascular structures and after a few seconds, a homogeneous moderate enhancement of the parenchyma, with parenchymal vessels still distinguishable and after the peak phase, a rapid homogeneous decrease in echogenicity. Values of time for contrast-enhanced ultrasonography were as follows: wash-in = 8.78 s, peak enhancement = 21.62 s and wash-out = 75.36 for left testicles; and wash-in = 10.76 s, peak enhancement = 21.50 s and washout = 81.81 for right testicles. The examination in Doppler mode showed testicular artery with monophasic-patterned waves in spermatic cord. These tests were easily applied in domestic cats and should be used as auxiliary techniques in the diagnosis of testicular abnormalities in this species / Mestre
167

Crescimento dos tecidos muscular e adiposo e qualidade da carne de novilhas de diferentes grupos genéticos no modelo biológico superprecoce /

Rodrigues, Erico. January 2007 (has links)
Resumo: O objetivo deste trabalho foi avaliar o crescimento de femeas bovinas de diferentes grupos geneticos no sistema intensivo de producao de carne superprecoce, analisando caracteristicas de desempenho como peso vivo (PV), ganho de peso medio diario (GPMD) e crescimento dos tecido muscular e adiposo atraves de avaliacao da area de olho de lombo (AOL) e espessura de gordura subcutanea (EGS) do musculo Longissimus dorsi e espessura de gordura subcutanea da garupa (EGG) do musculo Biceps femoris com imagens coletadas por ultra-som em tempo real nos animais vivos no inicio e fim do experimento. Foram utilizadas 42 femeas de 4 grupos geneticos sendo: 12 . Canchim x . Nelore (. CN), 12 . Canchim x . Nelore (. CN), 10 Simbrasil . Simental X . Nelore ( SIMB) e 10 Three-cross . Simental x . Nelore x . Angus (TC) desmamadas aos 210 dias de idade e peso vivo medio de 247,4 }16,5kg provenientes de creep-feeding durante a fase de cria, e confinadas por aproximadamente 132 }14 dias. Os animais foram abatidos, sendo o criterio de abate peso final de 350kg/PV e 5mm de gordura subcutanea. Os animais do grupo Three-cross apresentaram area de olho de lombo final e final ajustada para 100kg/PV inferiores aos demais grupos, porem apresentaram pesos finais superiores aos demais grupos com um tempo intermediario de confinamento e este grupo tambem apresentou os melhores ganhos de peso medio diario (GPMD) 1,07kg/dia (P<0,05). Nao houve diferenca significativa para area de olho de lombo inicial, espessura de gordura subcutanea (EGS) e para espessura de gordura subcutanea da garupa (EGG). Ajustando-se os valores de (EGG) e (AOL) para o menor numero de dias de confinamento onde os animais Three-cross e Simbrasil foram superiores (P<0,05) para (EGG F 114), e Simbrasil superior (P<0,05) para (AOL F 114). / Abstract: The objective of this study was to evaluate the growth of young heifers of different genetic groups in an intensive meat production system. It was used 42 animals of 4 different genetics groups: 12 . Canchim x . Nellore (. CN), 12 . Canchim x . Nellore (. CN), 10 Simbrasil . Simental X . Nellore (SIMB) and 10 Three way cross . Simmental x . Nellore x . Angus (TC). The animals received creep feeding supplementation and were weaned at 210 days of age with 247,4 }16,48kg. It was analyzed the characteristics of body weight (BWG), average daily gain (ADG), muscular and fat tissues growth. Real time ultrasound evaluation was used to measure ribeye area (RBA, Longissimus dorsi muscle), back fat thickness and P8 (Top rump, Biceps femoris) fat thickness. The feeding period was 132 (}14) days in feedlot system while daily gain was measured every 28 days. The animals were slaughtered with the final weight of 350 kg and 5mm of back fat thickness. The Three way cross heifers had smaller final and adjusted at 100 kg/PV ribeye area compared with the others groups. This group also had a greater final body weight, better average daily gain (GPMD), 1,07 kg/day (P<0,05) and an intermediate days of feeding. There was no significant differences for initial ribeye area (AOL), back fat thickness (EGS) and P8 (EGG), but when the values were adjusted for days of feeding, greater values (P<0,05) (EGG F 114) and (P<0,05) (AOL F 114), respectively. / Orientador: Mário de Beni Arrigoni / Coorientador: André Mendes Jorge / Banca: Roberto de Oliveira Roça / Banca: Rafael da Costa Cervieri / Mestre
168

Utilização da técnica de ultra-som em tempo real na avaliação in vivo de cordeiros /

Valle, Regina Célia Margarido, 1974- January 2008 (has links)
Orientador: Mário de Beni Arrigoni / Banca: Ricardo da Fonseca / Banca: Mauro Sartori Bueno / Resumo: O estudo teve por objetivo avaliar a utilização de ultra-som em tempo real - UTR com transdutores de diferentes freqüências na avaliação in vivo cordeiros de diferentes genótipos e das diferenças entre operadores. Foram utilizados 116 cordeiros machos desmamados, de diferentes raças, oriundos de rebanhos comerciais, nascidos no mesmo intervalo de data, durante os anos de 2006 e 2007, confinados com a mesma dieta e avaliados por ultra-sonografia 07 dias antes do abate. Utilizou-se de dois equipamentos de ultra-som Pie Medical Scan Vet 200, equipados com transdutores linear de 18cm e 8cm e, 3,5MHz e 7,5MHz respectivamente. Foram utilizadas correlações de Pearson para verificar a existência de correlação linear entre os métodos de ultra-som, entre raças, entre anos, entre métodos M1(transdutor de 18cm e freqüência 3,5MHz) e M2 (transdutor de 8cm e freqüência 7,5MHz) e as medidas de carcaça (rendimento, índice de compacidade da perna - ICP e índice de compacidade da carcaça - ICC). Houve correlação média entre as duas metodologias avaliadas, podendo viabilizar a otimização do equipamento de ultra-som, uma vez que o transdutor linear de 8cm e 7,5MHz, demonstrou-se viável para avaliação de gordura subcutânea em cordeiros. / Abstract: The trial had the objective of evaluating the use of real time ultrasound techniques with two different transducers on the in vivo evaluation of lambs from different genotypes and the differences among operator. 116 weaned male lambs from commercial flocks with different breeds, during the year 2006 and 2007, born in the same interval of time, confined and fed the same diet were evaluated 7 days before slaughter. Two Pie Medical Scan Vet 200 ultra-sound equipments with transducers of 18cm and 8cm with frequencies of 3.5MHz and 7.5MHz, respectively, were used.Pearson's Correlation were performed to verify the linear correlation between ultra sound transducer (18cm and frequency of 3.5MHz and 8cm and frequency of 7.5MHz), breeds, years and carcass measurements (leg compacity index and carcass compacity index). There was a medium correlation between the two methodology evaluated and the 8cm, 7.5 MHz transducer showed to be viable to evaluate the subcutaneous fat in lambs. / Mestre
169

Perfil de progesterona em macacos-da-noite (Aotus azarai infulatus) em cativeiro /

Coutinho, Leandro Nassar. January 2014 (has links)
Orientador: Wilter Ricardo Russiano Vicente / Coorientador: Frederico Ozanan Barros Monteiro / Coorientador: Marcus Antonio Rossi Feliciano / Banca: Priscila Viau Furtado / Banca: Rodrigo del Rio do Valle / Banca: Maria Emília Franco Oliveira / Banca: Lindsay Unno Gimenes / Resumo: Macacos-da-noite são tidos como excelentes modelos experimentais, que podem contribuir com o desenvolvimento de biotécnicas da reprodução em primatas. O monitoramento do ciclo é um procedimento básico, porém complexo em animais selvagens. Tem-se desenvolvido métodos não invasivos para avaliar o perfil hormonal reprodutivo desses animais expandindo o conhecimento sobre a fisiologia reprodutiva de primatas em cativeiro e vida livre. O presente estudo visa monitorar a atividade folicular e as concentrações fecais de metabólitos de progesterona para ampliar os conhecimentos sobre a fisiologia reprodutiva dessa espécie. Foram utilizadas 12 fêmeas adultas, pertencentes à colônia de reprodução de macacos-da-noite do CENP. O estudo foi realizado a partir do exame ultrassonográfico do ovário e colheita de fezes para monitoramento dos níveis de metabólitos de progesterona dos animais por enzimaimunoensaio. Por meio da dosagem de metabólitos de progesterona foi possível apenas sgerir o ciclo da espécie para o período estudado. Porém, os níveis basais (2,1 ± 0,8 ng/g de fezes secas), a médio do pico (36,6 ± 8,6 ng/g fezes secas), os níveis médios (4,7 ± 1,8 ng/g de fezes secas) e os valores mínimo (0,4 ng/g de fezes secas) e máximo (49,9 ng/g de fezes secas) de metabólitos de progesterona foram determinados para espécie em cativeiro sob estas condições. A determinação do pico e concentrações basais de metabólitos de progesterona, conjuntamente a avaliação ultrassonográfica são ferramentas não invasivas e factíveis na avaliação do ciclo estral de macacos-da-noite / Abstract: Owl Monkeys are considered excellent experimental models and can contribute to the development of biotechnologies of reproduction in primates. Monitoring the reproductive cycle is a basic procedure, however complex in wild animals. Noninvasive methods has been developed to assess the reproductive hormonal profile of these animals expanding knowledge on reproductive physiology of primates in captivity and the wild. This study aims to monitor follicular activity and fecal progesterone levels to increase knowledge about reproductive physiology of this species. 12 adult females belonging to the breeding colony of owl monkeys of CENP were used. The study was performed using the ultrasound examination of the ovaries and feces collection for monitoring the levels of metabolites of progesterone by enzymeimuneassay. By progesterone assay we may suggest the cycle of the species for the period studied. However, the baseline levels (2.1 ± 0.8 ng/g), mean peak (36.6 ± 8.6 ng/g), mean levels (4.7 ± 1.8 ng/g) and the minimum (0.4 ng/g) and maximum (49.9 ng/g) metabolites of progesterone were determined for the specie in captivity. The determination of the peak and basal levels of progesterone together to the sonographic evaluation are noninvasive and feasible in the evaluation of the estrous cycle in owl monkeys / Doutor
170

Sistema autônomo de inspeção de dutos

Geremia, Giovani January 2012 (has links)
A principal forma de transporte de petróleo e derivados, entre outras substâncias, são os dutos, e um dos processos críticos relacionados é a sua inspeção periódica, que é necessária e obrigatória, de alto custo devido à sua complexidade, e que na maioria das vezes são realizadas manualmente, em procedimentos demorados, pouco confiáveis e insalubres devido ao meio e aos riscos a que o trabalhador é exposto. Este trabalho tem o objetivo de testar diversas aplicações e situações de um sistema de inspeção de dutos robótico desenvolvido. O interesse de observação foi a praticidade e facilidade de montagem e desmontagem do equipamento sobre a tubulação, a agilidade dos graus de liberdade propostos para o sistema, a flexibilidade do equipamento para utilização de diferentes métodos de inspeção, a rapidez e confiabilidade dos resultados de inspeção por ultrassom para varredura de espessuras em busca de corrosão generalizada interna de uma tubulação e a capacidade de precisão e resolução desta inspeção por ultrassom. Para abordar estes pontos, foram realizados uma série de testes, inicialmente para verificação do bom funcionamento dos graus de liberdade do sistema, e posteriormente com métodos diferenciados de inspeção, como testes para medição geométrica externa de uma tubulação, testes com sistemas de ultrassom embarcado em laboratório e em campo com diferentes malhas de inspeção e com um ou múltiplos cabeçotes, e para diferentes tubulações e formatos de redução de espessuras de parede na tubulação. / The main way for transporting petroleum and substances alike is through ducts, and one of the most critic processes involved is the periodic inspection, wich is necessary and mandatory, with a high cost due to its complexity, and, in most cases, done manually in long time consuming procedures and with little reliability and high risk for the workers involved. This work is intended to test various situations of a robotic inspection system developed. The observation interest was the practicity and easiness of assembling and disassembling the equipment on the pipes, the agility of degrees of freedom proposed for the system, the flexibility of the equipment for the use in different methods of inspection, the quickness and reliability of the results by ultrasound for scanning different thicknesses of a duct in search of "generalized internal corrosion" and the level of precision and resolution of this ultrasound scan. To approach this topics, a series of test were conducted, at first to check if the degrees of freedom of the system were working as intended and afterwards with different methods of inspection, such as external geometric measurements of the pipes, tests with onboard ultrasound systems in lab and on the field with different inspection grades and with one or multiple ultrasound sensors, and for different kinds of pipes and thickness reduction shapes of the pipe's walls.

Page generated in 0.0425 seconds