Avaliação e controle de margem de carregamento em sistemas elétricos de potência / Evaluation and control of loading margin in electric power systems

Cristiane Lionço Zeferino 28 March 2011 (has links)
Neste trabalho é proposta a determinação do ponto de Máximo Carregamento (PMC) em sistemas elétricos de potência por meio do método da Função Lagrangiana Barreira Modificada (FLBM), uma variante do método de Pontos Interiores (PI). Também por meio do método da FLBM, busca-se determinar qual é a barra, para cada sistema, que apresenta a maior sensibilidade em relação ao fator de carregamento, ou seja, qual seria a primeira barra que deveria sofrer corte de carga a fim de aumentar a margem de carregamento do sistema e, assim, evitar o colapso de tensão. Para comprovação dos resultados obtidos por meio do método da FLBM utiliza-se a técnica de Análise de Sensibilidade (AS). A formulação do problema tem como restrições de igualdade as equações de balanço de potência do sistema elétrico e como restrições de desigualdade os limites de tensões nas barras, assim como os limites de geração de potência reativa nas barras com controle da referida potência. Estudos de casos foram realizados em um sistema de 3 barras e nos sistemas IEEE 14, 57, 118 e 300 barras; tais estudos demonstraram a robustez e a eficiência dos algoritmos propostos. / This work proposes the determination of the Maximum Loading Point (MLP) in electric power system via Lagrangian Modified Barrier Function (LMBF) method, a variant of Interior Point (IP). The LMBF method is also used to determine which bus, for each system, has the highest sensitivity of load factor, i.e., which bus would be the first to have load shedding in order to increase the loading margin system and thus prevent voltage collapse. To validate this approach, the Sensitivity Analysis (SA) technique was used for the confirmation of the results obtained by the LMBF method. The formulation of the problem considered the equations of power balance of the electrical system equality constraints, and the buses voltage magnitude limits, as well as the limits of reactive power control at the buses of that power inequality constraints. Case studies were conducted in a system of 3 buses and IEEE systems 14, 57, 118 and 300 buses, demonstrating the robustness and efficiency of the proposed algorithms.
32

Robust forward invariant sets for nonlinear systems

Mukhopadhyay, Shayok 27 August 2014 (has links)
The process of quantifying the robustness of a given nonlinear system is not necessarily trivial. If the dynamics of the system in question are not sufficiently involved, then a tight estimate of a bound on system performance may be obtained. As the dynamics of the system concerned become more and more involved, it is often found that using the results existing in the literature provides a very conservative bound on system performance. Therefore, the motivation for this work is to develop a general method to obtain a less conservative estimate of a bound on system performance, compared to the results already available in literature. The scope of this work is limited to two dimensions at present. Note that working in a two dimensional space does not necessarily make the objective easily achievable. This is because quantifying the robustness of a general nonlinear system perturbed by disturbances can very easily become intractable, even on a space with dimension as low as two. The primary contribution of this work is a computational algorithm, the points generated by which are conjectured to lie on the boundary of the smallest robust forward invariant set for a given nonlinear system. A well known path-planning algorithm, available in existing literature, is leveraged to make the algorithm developed computationally efficient. If the system dynamics are not accurately known, then the above computed approximation of an invariant set may cease to be invariant over the given finite time interval for which the computed set is expected to be invariant. Therefore, the secondary contribution of this work is an algorithm monitoring a computed approximation of an invariant set. It is shown that for a certain type of systems, this secondary monitoring algorithm can be used to detect that a computed approximation of an invariant set is about to cease to be invariant, even if the primary algorithm computed the set based on an unsophisticated dynamical model of a system under consideration. The work related to computing approximations of invariant sets is tested mainly with the curve tracking problem in two dimensions. The algorithm monitoring whether a computed approximation of an invariant set is about to cease to be invariant is inspired by work related to detecting Lithium-ion (Li-ion) battery terminal voltage collapse detection.
33

Proposição de uma técnica de parametrização geométrica para o fluxo de carga continuado /

Garbelini, Enio. January 2008 (has links)
Orientador: Dílson Amâncio Alves / Banca: Carlos Roberto Minussi / Banca: Francisco Villarreal Alvarado / Banca: Vivaldo Fernando da Costa / Banca: Walmir de Freitas Filho / Resumo: O fluxo de carga convencional é considerado inadequado para a obtenção do ponto de máximo carregamento devido a singularidade da matriz Jacobiana. Os métodos da continuação são ferramentas eficientes para a solução deste tipo de problema, e diferentes parametrizações são utilizadas para evitar a singularidade da matriz. Neste trabalho apresentase uma técnica de parametrização geométrica que possibilita o traçado completo das curvas PV sem os problemas de mal condicionamento. A técnica proposta associa a robustez com a simplicidade e a facilidade de compreensão. A singularidade da matriz Jacobiana é eliminada pela adição da equação de uma reta que passa por um ponto no plano formado pelas variáveis perdas de potência ativa totais e o fator de carregamento, dois parâmetros físicos de fácil compreensão. A técnica, aplicada aos sistemas do IEEE (14, 30, 57, 118 e 300 barras) e ao sistema brasileiro sul-sudeste (638 e 787 barras), mostra que as características do fluxo de carga não só são preservadas, mas também melhoradas. Diversos testes são realizados para proporcionar a comparação do desempenho do esquema de parametrização proposto para o método do fluxo de carga continuado. / Abstract: The conventional Newton's method has been considered inadequate to obtain the maximum loading point of power systems due to the Jacobian matrix singularity. Continuation methods are efficient tools for solving this kind of problem, and different parameterizations are used to avoid the matrix singularity. This paper presents a new geometric parameterization scheme that allows the complete tracing of the PV curves without ill-conditioning problems. The proposed technique associates the robustness to the simplicity and easy understanding. The Jacobian matrix singularity is overcome by the addition of a line equation, which passes through a point in the plane, determined by the real power losses and loading factor variables, two parameters with clear physical meaning. The application of this new technique to the IEEE systems (14, 30, 57, 118 and 300 buses) and to the Brazilian systems south-southeast (638 and 787 buses) shows that the characteristics of the conventional Newton's method are not only preserved but also improved. Several tests are carried out to compare the performance of the proposed parameterization scheme for the continuation power flow method. / Doutor
34

[pt] AVALIAÇÃO DAS CONDIÇÕES DE SEGURANÇA DE TENSÃO NA PRESENÇA DE MOTORES DE INDUÇÃO E CAPACITORES CHAVEÁVEIS / [en] VOLTAGE SECURITY ASSESSMENT IN THE PRESENCE OF INDUCTION MOTORS AND SWITCHABLE CAPACITORS

15 April 2005 (has links)
[pt] Após a incidência de inúmeros colapsos ocorridos nos sistemas de transmissão de energia devido ao uso extremo das linhas de transmissão, a estabilidade, ou mais adequadamente, a segurança de tensão tornou-se um assunto importante os últimos anos. A correta representação de cargas e de dispositivos de controle de tensão é cada vez mais importante na análise de segurança de tensão do sistema elétrico, em função da sua complexidade crescente e da necessidade de ações operativas mais precisas. A avaliação das condições de segurança de tensão é realizada com base em um modelo linearizado das equações de fluxo de carga, incluindo toda e qualquer equação de controle, e os índices resultantes são calculados a partir de um determinado ponto de operação. Em estudos off-line, este ponto é usualmente proveniente do resultado de um problema de fluxo de carga. É importante que os modelos matemáticos do sistema e seus componentes, de controles e de limites sejam compatíveis nos dois programas computacionais. Estuda-se neste trabalho a modelagem em regime permanente, e a incorporação à função de avaliação da segurança de tensão, de cargas do tipo motor de indução e do controle de tensão por faixa através de capacitores chaveáveis. Aspectos fundamentais da presença de motores de indução e capacitores chaveáveis na avaliação da segurança de tensão são apresentados e discutidos. São mostrados exemplos numéricos de avaliação dos índices de estabilidade de tensão que ilustram a necessidade de uma modelagem realista. / [en] After the incidence of innumerable collapses occurred in the energy transmission systems due to the extreme use of the transmission lines, the voltage stability, or more adequately, the voltage security became an important issue in the last years. The correct representation of loads and voltage control devices is important in the analysis of voltage security of the electrical system, due to its increasing complexity and to the necessity of more accurate and secure operative actions. The voltage security assessment is based on a linear model of the load flow equations, including all and any control equation, and the resulting indexes are calculated for a specified operating point. In off-line studies the operating point is usually obtained from a load flow algorithm. It is important that the system and its components mathematical models, control devices and limits are compatible in both computational programs. This work is concerned with the steady state modelling and its incorporation into the voltage security assessment function, of induction motor type loads and band voltage control by switchable capacitors. Fundamental aspects of induction motors and switchable capacitors in the assessment of voltage security are presented and discussed. Numerical examples of voltage stability assessment indexes are presented to illustrate the necessity of realistic modelling.
35

[pt] AVALIAÇÃO DO EFEITO DO ESGOTAMENTO DE RECURSOS DE CONTROLE SOBRE A ESTABILIDADE DE TENSÃO E CÁLCULO DE AÇÕES DE CONTROLE PREVENTIVAS / [en] EVALUATION OF THE EFFECT OF CONTROL RESOURCES EXHAUSTION ON VOLTAGE STABILITY AND CALCULATION OF PREVENTIVE CONTROL ACTIONS

09 March 2021 (has links)
[pt] Em todos os sistemas de potência, inclusive o brasileiro, verificam-se os níveis de tensão nos barramentos e de corrente nos ramos de transmissão na presença de contingências durante a operação em tempo real. A lista de contingências inclui a perda de qualquer ramo de transmissão, a perda de alguns pares de ramos e, de menor importância, a perda de geração. As condições de estabilidade de tensão também são checadas nesse momento. Esse trabalho simula eventos em que há perda do controle de tensão devido ao esgotamento da fonte controladora em todas as barras de tensão controlada da rede e verifica seus efeitos sobre a estabilidade de tensão. As simulações realizadas incluem também o evento em que há perda de capacidade de aumentar a geração de potência ativa em todos os geradores. Um método de ordenação pelo grau de severidade do evento sobre a estabilidade de tensão é empregado. Além disso, aproveitam-se os resultados obtidos e determinam-se as tensões e gerações mais influentes sobre a estabilidade de tensão de uma certa barra. Com a finalidade de aumentar a margem de potência dessa certa barra, calculam-se ações de controle preventivas, isto é variações nas tensões e, se necessário, nas gerações ativas. / [en] In all power systems, including the Brazilian one, it is common to check the voltage levels in busbars and current in the transmission branches in presence of contingencies during the real-time operation. The list of contingencies includes loss of any transmission lines, loss of some pairs of branches and, less importantly, loss of power generation. Voltage stability conditions are also checked at that time. This work simulates events in which there is loss of voltage control due to the exhaustion of the control source in all voltage-controlled busbars and verifies its effects on voltage stability. Simulations also include the event which shows loss of capacity to increase the active power generation in all generators. A ranking method is employed to order events by their degree of severity over voltage stability. In addition, the obtained results are used to determine the most influential voltages and generators over the voltage stability of a specific busbar. In order to increase the margin of power of this certain busbar, preventive control actions are calculated by keeping track of variations in voltage and, when necessary, in active power generations.
36

Calculating the Distance to the Saddle-Node Bifurcation Set

Borquez Caballero, Rodrigo Edgardo January 2009 (has links)
A power system will experience voltage collapse when the loads increase up to a certain critical limit, where the system physically cannot support the amount of connected load. This point identified as a Saddle- Node Bifurcation (SNB), corresponds to a generic instability of parameterized differential equation models and represents the intersection point where different branches of equilibria meet. At this point the jacobian matrix of the system is singular and the system loses stability bringing the typical scenario of voltage collapse. To prevent voltage instability and collapse, the computation of the closest distance from a present operating point to the saddle-node bifurcation set can be used as a loadability index useful in power system operation and planning. The power margin is determined by applying the iterative or direct method described in [16]. Numerical examples of both methods applied to IEEE 9-bus system and IEEE 39-bus system shows that the iterative method is more reliable although it requires a longer computation time. The stability of the system is negatively affected in two ways when generators reach their reactive power limits: the voltage stability margin is deteriorated, or immediate voltage instability and collapse is produced.
37

Effects of load modelling on Voltage Impasse Regions (VIR)

Angeles Antolin Linan, Maria January 2019 (has links)
Voltage Impasse Region (VIR) is a phenomenon in power systemswhose dynamics are describe by a set of Differential AlgebraicEquations (DAE). VIR denotes a state-space area where voltagecausality is lost, i.e. the Jacobian of the algebraic part of DAEis singular. In a Time Domain Simulation (TDS) once system trajectoriesenter VIR, TDS experiences non-convergence of the solution.Then, there is no reason to continue with the simulation. Thisis why it is important to understand the mechanisms that introduceVIR. It is known that VIR appears in relation to static, non-linearload models. However, it remained unknown what the cumulativeeffect of several static, non-linear loads would be.This master thesis has further expanded the concept of VIRby carrying out a structured study on how the load modelling affectsVIR. For this purpose, this thesis proposes a quasi-dynamicmethodology to map VIR in the relative rotor angle space. Themethodology introduces a new discrete index called Voltage ImpasseRegion Flag (VIRflag), which allows to determine if the algebraicequations of DAE are solvable or not and, thus, to locate VIR.A test system is used to test the proposed quasi-dynamic approach.The VIRflag was first used to map VIR for various load combinations.Then, the relationship between TDS non-convergence issuesand the intersection of a trajectory with VIR is examined toverify the proposed methodology.The proposed method has been proved to be efficient in the determinationof VIR regardless of the number of non-linear loads inthe power system. Among the static exponential load models, theConstant Power (CP) load component has been identified as theone with the largest influence on VIR appearance and shape. TheConstant Current (CC) loads induce ”smaller" VIR areas and theConstant Impedance (CI) load can only alter the shape of VIR inthe presence of non-linear load models. / VIR (Voltage Impasse Regions) är ett fenomen i kraftsystem varsdynamiska förlöp beskrivs av differential-algebraiska ekvationer(DAE). VIR betecknar ett område i tillståndsrummet där går förlorad,dvs Jakobianen av den algebraiska delen av DAE är singulärI tidsdomän-simuleringar (TDS) när en trajektoria träffar VIR,konvergerar TDS inte till en lösning. Då finns ingen anledning attfortsätta med simuleringen. Därför är det viktigt att förstå mekanismernasom introducerar VIR. Det är känt att VIR är relateradetill statiska, icke-linjära lastmodeller. Det var dock okänt vadden kumulativa effekten av flera statiska, icke-linjära belastningarskulle vara.Denna uppsats har vidareutvecklat begreppet VIR genom attgenomföra en strukturerad studie om hur lastmodellering påverkarVIR. För detta ändamål föreslår denna avhandling en kvasidynamiskmetod för att kartlägga VIR i det relativa rotorvinkelrummet.Metoden introducerar ett nytt diskret index som heterVoltage Impasse Region Flag (VIRflag), vilket gör det möjligt attbestämma om den algebraiska delen av DAE är lösbar eller inteoch därmed lokalisera VIR. Ett används för att testa det föreslagnakvasi-dynamiska tillvägagångssättet. VIRflag användes först för attkartlägga VIR för olika belastningskombinationer. Därefter granskasförhållandet mellan konvergensproblem i TDS och korsningenmellan en trajektoria och VIR för att verifiera den föreslagna metoden.Den föreslagna metoden har visat sig vara effektiv vid bestämningav VIR, oberoende av antalet icke-linjära belastningar. Bland destatiska exponentiella belastningsmodellerna har konstanteffektlast(CP) haridentifierats som den som har störst inflytande påVIR;s form. Den konstantströmlasten (CC) inducerar mindre"VIRområdenoch konstantimpedanslasten (CI) kan endast ändra formenav VIR i närvaro av icke-linjära belastningsmodeller.
38

[en] CRITERIA FOR DETERMINATION OF THE VOLTAGE STABILITY MARGIN FROM THE PERSPECTIVE OF THE OPERATION / [pt] CRITÉRIO PARA DETERMINAÇÃO DA MARGEM DE ESTABILIDADE DE TENSÃO SOB A PERSPECTIVA DA OPERAÇÃO

AMANDA ALVARENGA DIAS 12 November 2020 (has links)
[pt] Atualmente, o fenômeno de instabilidade de tensão representa uma das principais barreiras à operação estável das redes de energia elétrica, que tendem a crescer e a se tornarem cada vez mais interconectadas. A dificuldade de manter um perfil de tensão aceitável aumenta substancialmente e a estabilidade de tensão na operação dos sistemas elétricos deve ser preservada ao máximo, a fim de evitar os graves efeitos que a sua perda acarreta ao sistema. Esta dissertação atua na operação do sistema de energia elétrica, mais especificamente na área de operação em tempo real, onde é importante se conhecer a proximidade da condição operativa atual do sistema daquela que corresponde ao ponto crítico de estabilidade. Tal conhecimento permite que ações preventivas sejam realizadas no sentido de se evitar a instabilidade. O objetivo do trabalho é, a partir da comparação entre a margem sistêmica e a margem nodal, calculadas respectivamente pelo Fluxo de Potência Continuado e pelo método da Matriz D, determinar um critério para a margem de capacidade de carga, do ponto de vista de estabilidade de tensão, para a operação segura. No evento de cada contingência, calcula-se o maior crescimento de carga (margem), a partir do caso base, onde os índices nodais ainda são positivos. Define-se como margem mínima a menor dessas margens. A abordagem proposta foi avaliada através dos resultados obtidos com uma versão modificada do chamado sistema Nordic32. / [en] Currently, the phenomenon of voltage instability represents one of the main barriers to the stable operation of electric power networks, which tend to grow and become increasingly interconnected. The difficulty of maintaining an acceptable voltage profile increases substantially and the voltage stability in the operation of the electrical systems must be preserved to the maximum extent in order to avoid the serious effects that its loss entails on the system. This dissertation works in the operation of the electrical system, more specific in the area of operation in real time, where it is important to know the proximity of the operational condition of the current system that corresponds to the critical point of stability. Such knowledge allows preventive actions to be taken in order to avoid instability. The determination of appropriate margins for the various activities carried out in the electric power systems is not a trivial task, motivating the development of this dissertation. The objective of the work is from the comparison between a systemic margin and the nodal margin, calculated respectively by the Continued Power Flow and by the Matrix D method, to determine a criterion for the load capacity margin from the voltage stability point of view, for safe operation. In the event of each contingency, the largest growth (margin) is calculated from the base case, where the nodal indices are still positive. The smallest margin is defined as the minimum margin. The proposed approach was evaluated through the results obtained with a modified version of the so-called Nordic32 test system.
39

[en] USING ELECTRIC CIRCUIT EQUIVALENTS FOR VOLTAGE STABILITY ASSESSMENT / [pt] UTILIZAÇÃO DE CIRCUITOS ELÉTRICOS EQUIVALENTES NA AVALIAÇÃO DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO

LAURA CRISTINA PANIAGUA PALACIO 08 June 2015 (has links)
[pt] O surgimento do fenômeno de estabilidade de tensão na operação dos sistemas elétricos motivou centenas de pesquisadores a desenvolverem métodos que permitam detectar a proximidade à instabilidade de tensão, com eficiência computacional, e tomar medidas acertadas para garantir a operação confiável e segura. Neste trabalho são analisados diferentes métodos que permitem transformar sistemas de grande porte em circuitos simples: o circuito equivalente entre geradores e cargas, baseado no cálculo de correntes de curto-circuito, na técnica de redução de rede pela eliminação de barras intermediárias e no equivalente de Thévenin. É analisada a utilização destes equivalentes na avaliação das condições de estabilidade de tensão com sistemas-testes de 3 e 4 barras. Através de diferentes testes verificou-se que o circuito equivalente entre geradores e cargas e a técnica de redução de rede não podem ser usados para o cálculo de índices de avaliação das condições de estabilidade de tensão, enquanto que, usando circuito equivalente de Thévenin encontrou-se um método que funciona corretamente para barra de carga terminal, barra não-terminal e barra de tensão controlada por gerador. / [en] The emergence of voltage stability phenomenon in the operation of power systems has motivated hundreds of researchers to develop methods to detect the proximity to voltage instability, with computational efficiency and to take all necessary and appropriate measures to ensure reliable and safe operation. In this work, different methods that allow transforming large systems into simple circuits were analyzed, such as the equivalent circuit between generators and loads, based on the calculation of short-circuit currents; the network reduction technique for eliminating intermediate buses; and the Thévenin equivalent. The application of these equivalents on voltage stability assessment of 3 and 4 bus testing systems were extensively tested. At the end, it was verified that that the equivalent circuit between the generator and load, and the network reduction technique, cannot be used for calculating the voltage stability conditions evaluation indexes. However, using Thévenin equivalent circuit, it was found a proper method, which works correctly for terminal buses, transit buses and voltage-controlled buses.
40

[en] LOSS OF CONTROL AND INADEQUATE VOLTAGE CONTROL ACTION IN THE EVALUATION OF VOLTAGE STABILITY CONDITIONS / [pt] PERDA E INADEQUAÇÃO DO CONTROLE DE TENSÃO NA AVALIAÇÃO DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO

OSCAR CUARESMA ZEVALLOS 03 February 2015 (has links)
[pt] Esta pesquisa está relacionada à avaliação das condições de estabilidade de tensão em pontos de operação do sistema elétrico. A modelagem de geradores / compensadores síncronos e compensadores estáticos são analisadas. Estabeleceram-se os melhores modelos com controle de tensão ativo e com perda do controle. A questão da adequação do controle de tensão foi tratada através da análise dos elementos da matriz de sensibilidade entre as grandezas controladoras e as tensões controladas. Os índices de estabilidade de tensão foram calculados. Em todos os casos, a perda de controle de tensão tem impacto negativo sobre as condições de estabilidade de tensão. Nos casos com ação de controle inadequada, independe da relação inversa entre grandeza controladora e tensão controlada, um aumento da tensão na barra controlada teve um impacto positivo sobre as condições de estabilidade de tensão, e uma diminuição da tensão na barra controlada teve impacto negativo sobre as condições de estabilidade de tensão. Esse é o resultado esperado também quando a ação de controle é adequada. / [en] This research is related to the evaluation of voltage stability conditions of operating points of the power system. It has been studied the modelling of synchronous generators/synchronous compensators and static var compensators. The best models were established with active voltage control and with loss of control. The issue of voltage control was treated through analysis of the matrix sensitivity elements between the controlling variables and voltages at controlled buses. The voltage stability indexes were evaluated. In all cases, control loss proved to have a negative impact on voltage stability conditions. In cases with inadequate control action, results are non-dependent of the opposed relation between the controlling variable and voltage at controlling bus, an increase on voltage at controlled busbar proved to have a positive impact on voltage stability conditions, and a decrease on voltage at controlled busbar proved to have a negative impact on voltage stability conditions. This is also expected when the control action is appropriate.