• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 9
  • 9
  • 9
  • 9
  • 8
  • 2
  • 1
  • 1
  • Tagged with
  • 200
  • 119
  • 68
  • 62
  • 56
  • 47
  • 45
  • 44
  • 39
  • 35
  • 30
  • 29
  • 25
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Comportamento tribológico de três superligas de cobalto em ensaios de microabrasão. / Tribological behavior in microabrasion of three cobalt-based superalloys.

Flávio Parreiras Marques 14 June 2017 (has links)
As superligas à base de cobalto são bem conhecidas por sua excelente resistência ao desgaste. Muitas pesquisas reportadas na literatura abordam o comportamento do desgaste destas ligas, seja no desgaste por deslizamento, erosivo ou abrasivo. Não obstante, o desgaste microabrasivo destas ligas não tem sido muito investigado, apesar dos danos causados por este tipo de solicitação. O comportamento do desgaste microabrasivo de três superligas à base de cobalto: a) 48% Co, 29 %Cr, 19 % Fe; b) uma liga com composição química próxima à da liga comercial Tribaloy T400 (Co 56 %, Cr 8.5%, Mo 29% Si 3.3 %) e c) uma liga com composição próxima à da liga comercial Stellite 6 (Co 64%, Cr 24 %, W 4.2 %, C 2,3%) foram investigadas. Os ensaios de microabrasão foram conduzidos com três abrasivos SiO2, Al2O3, e SiC em suspensão em água destilada, com concentração de 0,1 g/cm3. A carga aplicada foi de 0,3 N, a velocidade angular 20 rpm e a distância total de deslizamento, 48 metros. A análise das superfícies desgastadas por microscopia óptica, eletrônica de varredura e por perfilometria de contato mostraram que o tamanho, forma e dureza dos abrasivos podem influenciar significativamente os coeficientes de desgaste. Os ensaios conduzidos com partículas abrasivas de SiC e Al2O3 apresentaram maiores coeficientes de desgaste que os conduzidos com partículas de SiO2. A Liga Co-Cr-Fe mostrou os maiores coeficientes de desgaste quando comparada com as demais ligas, devido à baixa fração volumétrica de partículas de segunda fase, duras, precipitadas em sua microestrutura. Durante os ensaios, as três ligas, ensaiadas com os três diferentes abrasivos, apresentaram coeficientes de desgaste crescentes com o aumento da dureza do abrasivo; observou-se uma variação linear dos coeficientes de desgaste com a razão entre a dureza do abrasivo (Ha) e a dureza composta da liga (Hs), com R2 = 0.74. O micromecanismo dominante em todos os ensaios foi o desgaste abrasivo a dois corpos (grooving wear). A liga com composição próxima à da liga comercial Tribaloy T400, contendo fases de Laves dispersas em sua microestrutura, apresentou uma transição de micromecanismo de desgaste dúctil para frágil, quando submetida a ensaios com partículas abrasivas de Al2O3. Assim sendo, o volume de material removido nesta liga foi ligeiramente maior que o observado no ensaio com partículas de SiC. Na liga contendo baixa fração volumétrica de partículas de segunda fase, com matriz constituída por Co (CFC), observou-se uma camada subsuperficial nanocristalina de aproximadamente 1 µm de espessura, severamente deformada, imediatamente abaixo da superfície desgastada. Concluiu-se que o desgaste microabrasivo induziu a recristalização a frio do material encruado, com formação de grãos equiaxiais de dimensões nanométricas. / Cobalt alloys are well known for their excellent wear resistance. Many investigations are reported in literature related to the behavior of erosive, abrasive or sliding wear of these alloys. Nevertheless, the micro-abrasive wear of these alloys has not been thoroughly investigated, despite the damage caused by this type of wear. The microabrasive wear behavior of three cobalt alloys: a) 48 wt.% Co, 29 wt.% Cr, 19 wt.% Fe; b) an alloy with chemical composition close to Tribaloy T400 (56 wt.% Co, 8.5 wt.% Cr, 29% wt. Mo, 3.3 wt. %Si) and c) an alloy with chemical composition close to Stellite 6 (64wt.% Co 24 wt.% Cr, 4.2 wt.% W, 2,3 wt.% C were investigated. The tests were carried out using three 0,1 g/cm3 slurries composed by SiO2, Al2O3, and SiC particles, in suspension in distilled water. The applied load was 0.3 N, the rotational speed 20 rpm and the total sliding distance 48 m. Analysis of the worn surfaces of the tested alloys by Optical Microscopy, Scanning Electron Microscopy and Contact Stylus Profilometry showed that abrasive size, shape and hardness could significantly influence the wear coefficients. The tests carried out with SiC and Al2O3 slurries resulted in greater wear rates than those carried out in SiO2 slurry. Stellite 250, showed the greatest wear coefficient, compared to the two other experimental alloys, due to a very low volume fraction of hard second phase particles in the microstructure. Wear coefficients decreased with increasing abrasive particles hardness. An approximate linear correlation with the ratio between the hardness of the abrasives (Ha) and the compound hardness of the alloys (Ha) with a correlation factor R2= 0.74. The dominant wear micromechanism observed in all tests was two-body abrasion (grooving wear). The modified T400 alloy, containing Laves phase showed a transition from ductile to brittle wear mechanisms when testing with alumina slurries. The worn volume was slightly greater than the one observed with SiC. A severely deformed nanocrystalline layer was identified, immediately below the worn surface. It was concluded that cold recrystallization of the work-hardened material occurred, with the formation of nano sized equiaxed grains.
132

Estimativa da idade pelos dentes atraves de sistema computadorizado integrado

Galvão, Malthus Fonseca 20 October 1999 (has links)
Orientador: Roberto Jose Gonçalves / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T21:27:37Z (GMT). No. of bitstreams: 1 Galvao_MalthusFonseca_M.pdf: 8227355 bytes, checksum: fef3b0ca9abcf0d9863972e10c678443 (MD5) Previous issue date: 1999 / Resumo: A odontologia é a área do conhecimento mais importante na estimativa da idade humana, pela menor variabilidade na cronologia de eventos e maior perenidade de características. Existem diversas tabelas e equações para a cronologia dos eventos dentários fisiológicos, sendo importante, do ponto de vista pericial, uma análise o mais global possível. A aplicação manual de todas as tabelas e a comparação entre as mesmas, constitui tarefa dispendiosa e passível de erros. Visando a dinamizar esta tarefa, garantir confiabilidade aos seus resultados, foi construí do um sistema computadorizado, utilizando-se, principalmente, o programa de computador "Microsoft Visual Basic 6.0", criando-se formulários eletrônicos para cada caracter: mineralização, erupção e alterações regressivas, incluindo representações gráficas. Todos os registros foram acoplados a um banco de dados modelado em "Microsoft Access 97". A partir de uma idade determinada, foi possível estimar os estágios dentár ios de mineralização, os estados eruptivos e as alterações regressivas. Conhecendo-se os caracteres, foi possível estimar a idade. Os cálculos foram instantâneos, possibilitando uma análise completa e com uma probabilidade de erro de processamento igual a zero, tendo o sistema aplicações práticas pericial e didática imediatas / Abstract: Dentistry is the most important part of the wisdom to the knowledge to estimate the human age, because it presents the minor variability and major perenniallyty of its variables. There are a lot of tables and equations to the chronology of physiological dental events, being important in the pericial view a global analisys of them. The manual application of every tables and equations is a waste of work, that can bring errors. A computer system was constructed using, mainly the computer program "Microsoft Visual Basic 6.0", with electronic forros for each charaeter: mineralization, eruption and regressive alterations, including graphical representations. AlI the data was saved in a data bank constructed with "Microsoft Access 97". Using as a basis from a determina te age it was possible to estima te the mineralization, eruption and regressive alterations states, and the inverse as well. The calculation was fast, almost immediate ~d a complete analysis with an error probability of I process equal zero, and the system presents practical, teach and resear~h immediate applications / Mestrado / Mestre em Odontologia Legal e Deontologia
133

Tratamento cirurgico-restaurador de recessão gengival associada a lesão cervical não-cariosa : resultados de diferentes abordagens e fatores locais contribuintes / Survical-restorative treatment of gingival recession associated with non-carious cervical lesion : results of different approaches and the influence of the local factors

Santamaria, Mauro Pedrine 10 July 2009 (has links)
Orientador: Enilson Antonio Sallum / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T12:01:49Z (GMT). No. of bitstreams: 1 Santamaria_MauroPedrine_D.pdf: 1906873 bytes, checksum: 996991755e8909f6c85dd127ec284d0f (MD5) Previous issue date: 2009 / Resumo: Recessões gengivais estão freqüentemente associadas às lesões cervicais não-cariosas. O tratamento dessa lesão combinada é um desafio. Trabalhos recentes têm apresentado resultados de tratamento conjunto de cirurgia periodontal e dentística restauradora para tratamento da lesão combinada. Porém nenhum trabalho demonstrou resultados de longo prazo desse tipo de abordagem, além de variações desse tratamento e dos fatores anatômicos locais que poderiam influenciar na resultado dessas terapias. Portanto, os objetivos do presente estudo foram: 1. Apresentar os resultados após 2 anos de tratamento de recessões gengivais associadas à lesões cervicais tratadas com retalho posicionado coronariamente (RPC) sozinho ou associado à restauração de ionômero de vidro modificado por resina (CIV). 2. Avaliar os resultados, após 6 meses de tratamento do enxerto de tecido conjuntivo (ETC) associado ou não à restauração de CIV para tratamento da lesão combinada. 3. Avaliar a possível influência das características anatômicas locais no recobrimento das lesões combinadas tratadas pelas técnicas do retalho posicionado coronariamente e pelo enxerto de tecido conjuntivo. Para o primeiro objetivo, foi realizado um estudo clínico controlado e randomizado que foram incluídos 16 indivíduos apresentando duas recessões gengivais bilaterais associadas à lesões cervicais em caninos ou pré-molares superiores. Os defeitos foram tratados com RPC sozinho ou associado à restauração de CIV. Os resultados não demonstraram diferença significante entre os grupos após 2 anos com relação à redução da recessão gengival, ganho no nível clínico de inserção e sangramento à sondagem. Para o segundo objetivo, foi realizado um estudo clinico controlado e randomizado que foram incluídos 40 indivíduos apresentando uma recessão gengival associada à lesão cervical em caninos ou pré-molares superiores. Os defeitos foram tratados com ETC sozinho ou associado à restauração de CIV. Os resultados não demonstraram diferença estatisticamente significante entre os grupos após 6 meses com relação à redução da recessão gengival, ganho no nível clínico de inserção, ganho de tecido queratinizado e sangramento à sondagem. No entanto, o grupo que recebeu ETC e a restauração de CIV foi estatisticamente melhor na redução da hipersensibilidade dentinária. Para o terceiro objetivo, as características anatômicas locais dos indivíduos dos dois estudos clínicos prévios foram medidas e analisadas através de regressão linear multipla. Os resultados demonstraram correlação estatisticamente significante entre a profundidade da lesão cervical não-cariosa e o a redução na recessão gengival quando RPC foi utilizado de forma isolada. A altura da lesão combinada também apresentou correlação estatisticamente significante com a redução da recessão gengival para ambos os estudos. Além disso, a deiscência óssea apresentou correlação estatisticamente significante quando ETC foi utilizado. Dentro dos limites desse estudo, pode-se concluir que a restauração de ionômero de vidro modificado por resina parece não interferir no recobrimento da lesão combinada após 2 anos de avaliação, quando o retalho posicionado coronariamente foi utilizado e após 6 meses quando o enxerto de tecido conjuntivo foi utilizado. A profundidade da lesão cervical pode ter alguma influência quando RPC é utilizado e a deiscência óssea parece não interferir negativamente no recobrimento quando ETC foi utilizado. / Abstract: Gingival recessions are frequently associated with non-carious cervical lesion. Previous studies have shown results from a combined treatment (periodontal surgery plus restoration of the cervical lesion) to deal with the association of these two lesions. However, there is lack of information regarding the long term evaluation of the combined treatment. Moreover, no additional information regarding other surgical techniques and the influence of the local anatomical characteristics have not been evaluated. Thus, the objectives of this study were: 1. Evaluate the 2-year-follow-up outcome of the treatment of gingival recession associated with non-carious cervical lesions by coronally advanced flap alone (CAF), or in combination with a resin-modified glass ionomer restoration 2. Evaluate the 6-month-follow-up outcome of the treatment of gingival recession associated with cervical lesion by connective tissue graft alone (CTG), or in combination with a resin-modified glass ionomer restoration, and 3. Evaluate the possible influence of local anatomy on the amount of soft tissue coverage achieved and on the clinical attachment gain by the use of CAF and CTG, alone or in combination with resin-modified glass ionomer restoration to treat the combined defect. For the first objective, 16 patients with bilateral Miller Class I buccal gingival recessions, associated with non-carious cervical lesions were selected. The defects received either CAF alone or CAF plus a resin-modified glass ionomer restoration. The results showed that both groups showed statistically significant soft tissue coverage. The differences between groups were not statistically significant in reduction of gingival recession, gain in the clinical attachment level, and bleeding on probing after 2 years. For the second objective, 40 patients with Miller Class I buccal gingival recessions, associated with non-carious cervical lesions were enrolled. The defects were randomly assigned to receive either CTG alone or CTG plus a resin-modified glass ionomer restoration. The results showed that both groups showed statistically significant soft tissue coverage. The differences between groups were not statistically significant in gingival recession, gain in the clinical attachment level, and bleeding on probing, after 6 months. However, the group CTG plus the restoration showed statistically significant reduction in dentin sensitivity when compared to CTG alone. For the third objective, the local anatomical characteristics from the patients enrolled in the 2 previous studies were correlated with the reduction of the gingival recession and the gain in the clinical attachment level using Stepwise Multivariate Linear Regression. The results showed that the cervical lesion depth was significantly correlated with reduction in gingival recession, when considering data from the CAF group. The cervical lesion height was statistically correlated with the reduction in gingival recession when the two groups were analyzed. Additionally, the bone level was statistically correlated with reduction in gingival recession when evaluating the CTG group. Within the limits of the present study it can be concluded that the presence of the resin-modified glass ionomer restoration may not interfere with the amount of coverage achieved either by CAF after 2 years or CTG after 6 months. The cervical lesion depth may have some influence on the final coverage achieved when CAF is applied and the bone level may not play any role when CTG is applied. / Doutorado / Periodontia / Doutor em Clínica Odontológica
134

Análise da resistência ao desgaste abrasivo de um revestimento duro obtido pela deposição, por soldagem, de uma liga a base de ferro / Analysis of the abrasive wear resistance of a hardfacing obtained through the deposition by the welding of an iron based alloy

Cleyton Fernandes Ferrarini 05 May 1998 (has links)
O presente trabalho apresenta a análise da resistência ao desgaste abrasivo de um revestimento duro e do aço SAE 5160. O revestimento foi obtido pela deposição de uma liga ferrosa através de processo de soldagem \"TIG\" sobre um aço ABNT 1020. Aliga foi desenvolvida com a utilização de CR e Nb como elementos formadores de carbonetos, proporcionando uma microestrutura constituída, no estado bruto de fusão, de uma rede de carbonetos (Cr, Fe)7C3 interdendríticos e NbC dispersos em uma matriz austenítica. Corpos de prova revestidos foram submetidos a tratamentos térmicos de normalização, têmpera, sub-zero e revenido, visando a obtenção de diferentes microestruturas na matriz, enquanto que o aço SAE 5160 foi temperado e revenido de acordo com o procedimento utilizado na confecção de ferramentas agrícolas com este material. A resistência ao desgaste do revestimento foi superior à do aço SAE 5160 nos dois tipos de ensaios de abrasão realizados, sendo os melhores desempenhos apresentados pelo revestimento temperado no ensaio realizado com equipamento do tipo pino sobre lixa e pelo revestimento temperado e revenido no ensaio do tipo roda de borracha/areia seca. A identificação dos mecanismos de remoção de material predominantes nos ensaios abrasivos foi possibilitada pela observação das superfícies desgastadas dos corpos de prova através de microscopia eletrônica de varredura. / The present work presents an analysis of the abrasive wear resistance of a hardfacing and of the SAE 5160 steel. The hardfacing was obtained by the deposition of a iron based alloy through \"TIG\" welding on a ABNT 1020 steel. This alloy was developed with the use of Cr and Nb as carbide forming elements , resulting in a microstructure formed by a carbide net of M7C3 interdendritic in a austenitic matrix. The hardfacing samples suffered heat treatment of normalizing, hardening, tempering and subzero, viewing the achievement of differents microstructure, while the SAE 5160 steel suffered hardening and tempering according to the production process used in the agricutural tool manufacturing. The wear resistance of the hardfacing overcame the SAE 5160 steel in both types of abrasion wear tests, and the best performances were presented by hardening hardfacing in the pin wear test and by the tempering hardfacing in the rubber wheel/dry sand test. The identification of the material removal mechanisms in the abrasive tests was made by the observation of the worn surfaces of the samples through the scanning eletronic microscopy.
135

Efeito da radioterapia, quimioterapia e quimioradioterapia na dentina radicular após erosão, cárie e abrasão / Effect of radiotherapy, chemotherapy and chemoradiotherapy on root dentin after erosion, caries and abrasion

Fillus, Thaís Marilia 05 February 2018 (has links)
O objetivo do presente estudo foi avaliar as alterações ocorridas na dentina radicular de dentes permanentes provenientes de pessoas submetidas aos diferentes tratamentos antineoplásicos após erosão (in situ), cárie (in situ) e abrasão (in vitro). Foram selecionados dentes extraídos de pacientes que realizaram tratamentos para câncer na região de cabeça e pescoço (CCP) no Hospital das Clínicas de Ribeirão Preto ou no Hospital do Câncer de Barretos Os dentes foram divididos em grupos de acordo com o tratamento antineoplásico: CO- controle: dentes extraídos de pacientes saudáveis; RTX - radioterapia na região de cabeça e pescoço; QTX quimioterapia; QRT quimioradioterapia. Todos os fragmentos de dentina radicular foram aleatoriamente distribuídos entre os voluntários de cada fase. Na primeira fase foi realizada a erosão in situ; na segunda fase foi feito o processo carioso nos substratos dentais in situ e na 3ª fase foi realizado o teste de abrasão por escovação in vitro. As variáveis de resposta quantitativas foram: perfil de desgaste, degrau formado, número, área e perímetro dos túbulos dentinários, rugosidade da superfície, volume perdido e quantificação do tecido desmineralizado; e qualitativamente analisou-se a morfologia da superfície. Na erosão observou-se que o processo erosivo produziu um aumento no número, diâmetro e área dos túbulos de modo geral, sendo que apenas QRT apresentou maior perda estrutural e diferente estatisticamente em relação aos outros grupos (p<0,05). No processo carioso nenhum tratamento proporcionou alteração quantitativa maior que o controle (p>0,05), contudo morfologicamente foi observado que o tecido dentinário submetido à QRT apresentou uma superfície mais amorfa. Na abrasão, o grupo RTX apresentou maior perda estrutural e diferente estatisticamente de todos os grupos (p<0,05), além de morfologicamente apresentar um maior padrão de desgaste. Conclui-se que os tratamentos antineoplásicos alteraram a dentina radicular e afetaram os processos de erosão, cárie e abrasão / The aim of the present study was to evaluate the alterations on root dentin of permanent teeth from individuals submitted to different antineoplastic treatments after erosion (in situ), caries (in situ) and abrasion (in vitro).Teeth extracted from patients who underwent cancer treatments in the head and neck region (HNC) at Hospital das Clínicas de Ribeirão Preto or at Hospital do Câncer de Barretos were selected and divided into groups according to antineoplastic treatment: CO-control: teeth extracted from healthy patients; RTX- radiotherapy in the head and neck region; QTX - chemotherapy; QRT - chemoradiotherapy. All fragments of root dentin were randomly distributed among the volunteers of each stage. In the first phase, erosion was carried out in situ; in the second phase the carious process was performed on the dental substrates in situ and the third phase was performed the in vitro abrasion test by teeth-brushing machine. The quantitative response variables were: wear profile, step, number, area and perimeter of the dentinal tubules, surface roughness, volume loss and quantification of the demineralized tissue; and qualitatively was analyzed the surface morphology. For the erosive process, it was observed an increase in the number, diameter and area of the tubules for all groups, but only QRT presented greater structural loss with statistical difference in relation to the other groups (p <0.05). For the carious process, no treatment provided a quantitative alteration greater than the control (p> 0.05). However, morphologically, it was observed that the dentinal tissue submitted to QRT presented a surface more amorphous. For the abrasion, the RTX group presented higher structural loss and statistically different from the other groups (p <0.05), besides presenting, morphologically, a higher pattern of wear. It was concluded that the antineoplastic treatments changed the root dentin and affected the processes of erosion, caries and abrasion
136

Avaliação in situ do efeito do gel contendo euclea natalensis na superfície dentária, antes do desafio erosivo seguido ou não da abrasão / Evaluation in situ of the gel containing natalensis euclea effect on the tooth surface before the erosive challenge with or without abrasion

Xavier, Cheila Nilza Hamina 29 November 2011 (has links)
Este estudo avaliou in situ a ação do gel contendo euclea natalensis na redução da erosão associada ou não abrasão em esmalte e dentina humanos. O estudo foi realizado em duas fases cruzadas de cinco dias cada (SG - sem gel e CG - com gel) nas quais 10 voluntários utilizaram placas palatinas com 4 blocos de esmalte e 4 blocos de dentina, distribuídos em duas fileiras horizontais contendo 4 blocos, correspondendo aos subgrupos: erosão (Eros); erosão + abrasão (30min) (Eros + Abras). Em fases alternadas metade dos voluntários teve a aplicação do gel em todos espécimes do aparelho e na outra metade os espécimes não sofreram tratamento nenhum. O gel foi aplicado durante 5 minutos, sendo o mesmo removido após este tempo. Na etapa experimental os aparelhos foram imersos em refrigerante 4x ao dia, por 5 minutos. A seguir o aparelho foi colocado na boca por 30 minutos. Após este período os voluntários escovaram 4 espécimes da fileira Eros + Abras e recolocaram o aparelho. A outra fileira (Eros) não foi escovada. A análise da perda de estrutura dentária foi realizada por meio de teste de perfilometria e microdureza. Foi utilizada a análise de variância (ANOVA) a 2 critérios (presença ou ausência da aplicação do gel) de acordo com cada substrato e o teste TUCKEY (p<0,05). Não houve associação entre perda de dureza e condições ou grupos testados (p>0,05). O desgaste dentário médio nos blocos de esmalte para o grupo CG foi de 12,86µm eros e 12,13µm eros+abras e para os blocos de dentina foi de 5,95µm eros e 6,16µm eros+abras. A média de desgaste dentário para o grupo SG, em blocos de esmalte foi de 14,08µm eros e 16,29µm eros+abras e, nos blocos de dentina foi de 13,64µm eros e 12,63µm eros+abras. Houve diferença significativa entre os grupos (p<0,05). Concluiu-se que o gel contendo euclea natalensis é capaz de reduzir o desgaste associado ou não a abrasão, independente do tipo de substrato, esmalte ou dentina. / This study investigated the action of in situ gel containing euclea natalensis on reducing erosion associated or not with abrasion in the human enamel and dentin. The study was performed into two phases crossed in five days each (WOG-without gel and WG- with gel) in which ten volunteers used acrylic palatal appliances with four blocks of enamel and four dentin, distributed in two horizontal rows containing four blocks, corresponding to the subgroups: erosion (Eros); erosion + abrasion (30min) (Eros + Abras). In alternating phases half the volunteers had the applying the gel at all specimens. And the other half of the volunteers have not suffered any treatment. The gel was applied during 5 minutes, being removed after this time. In stage experimental, the blocks were subjected to erosion by immersion of the appliances into soft drink for five minutes, 4 times a day. The appliance was then replaced into the mouth for 30 minutes. After this period the volunteers brushed row (eros+abrasion) and replaced into the mouth. The row (eros) was not brushed. The analysis of the dental structure were determined using profilometry and microhardness tests. ANOVA by two criteria (presence or absence of application of gel) in agreement with each the substrate and Tukey test were applied (p <0.05). Microhardness and conditions or groups tested were not found association (p> 0.05). The mean wear in enamel blocks was 12.86µm eros and 12.13µm eros + abras in the WG group and in dentin blocks was 5.95 µm eros and 6.16µm eros+ abras. The mean wear in enamel blocks was 14.08µm eros and 16.29µm eros+abras for the WOG group and in dentin blocks was 13.64µm eros and 12.63µm eros + abras. There was significant difference between groups (p <0.05). It concluded that the gel containing Euclea Natalensis can reduce erosion with or without abrasion, independently of the substrate type, enamel or dentin.
137

Avaliação da superfície do esmalte após diferentes tempos de jateamento de óxido de alumínio indicados para a colagem de braquetes / Evaluation of enamel surface after different times of aluminium oxide sandblasting indicated for bracket bonding

Gabarrone, Lilian Rocha 01 July 2016 (has links)
Objetivo: avaliar e comparar os efeitos do jato de óxido de alumínio sobre a superfície do esmalte, quando aplicados por tempos diferentes. Material e métodos: 110 pré-molares foram obtidos por meio de doações do Banco de Dentes da FOUSP. Os dentes foram divididos aleatoriamente em 5 grupos (n=22) para a aplicação de jato de óxido de alumínio por diferentes períodos de tempo. Nos grupos A, B, C, D e E o jato de óxido de alumínio de 50 ?m foi aplicado, respectivamente, por 01, 03, 05, 07 e 10 segundos. Avaliações quantitativas da superfície do esmalte foram realizadas pelas análises das alterações do perfil e da rugosidade (Sa) da superfície vestibular antes e após o seu jateamento, por meio do medidor de perfil Form Talysurf Intra (Taylor Hobson - AMETEK Inc, Pennsylvania) e do interferômetro a laser Talysurf CCl Lite (Taylor Hobson - AMETEK Inc, Pennsylvania), respectivamente. Uma avaliação qualitativa da superfície do esmalte foi realizada por meio da microscopia eletrônica de varredura (MEV). Para esta última análise, um exemplar de cada grupo foi selecionado aleatoriamente para que as superfícies de esmalte jateadas fossem devidamente preparadas para as suas leituras. Os dados quantitativos foram comparados pelo teste ANOVA, seguido do teste post hoc de Tukey, adotando-se um nível de significância de 5% (p= 0,05). Resultados: observou-se maior alteração do perfil e da rugosidade conforme se aumentou o tempo de aplicação do jato de óxido de alumínio. Porém, com relação à alteração do perfil, diferenças estatisticamente significantes foram observadas somente entre o grupo A (1s) quando comparado aos grupos D (7s) e E (10s), e entre o grupo B (3s) quando comparado com o grupo E (10s). Quanto à rugosidade, verificou-se diferença estatisticamente significante apenas entre o grupo E (10s) quando comparado aos demais grupos. As cinco imagens obtidas pelo microscópio eletrônico de varredura (MEV) demonstraram bastante semelhança entre si, com padrão de condicionamento marcado por picos e vales, porém as imagens dos esmaltes jateados por 1 e 3 segundos apresentaram esses picos e vales em menor quantidade. Conclusão: a perda de estrutura dentária e a rugosidade da superfície do esmalte aumentaram conforme se aumentou o tempo de aplicação do jato de óxido de alumínio; a aplicação do jato de óxido de alumínio por 1 e 3 segundos promove menos perda de estrutura de esmalte do que quando se jateia o esmalte por 10 segundos; maior rugosidade pode ser obtida com o jateamento de óxido de alumínio por 10 segundos; entretanto, o aspecto morfológico do esmalte dentário é bastante similar, independentemente do tempo de jateamento. / Objective: To evaluate and compare the effects of aluminium oxide sandblasting on enamel surface when applied at different times. Materials & Methods: 110 premolars were obtained from the local tooth bank. The teeth were randomly divided into 5 groups (n = 22) for application of aluminium oxide sandblasting at different times. In Groups A, B, C, D and E, sandblasting with 50-?m aluminium oxide particles was applied for 01, 03, 05, 07 and 10 seconds, respectively. Quantitative assessments of enamel surface were performed by analysing changes in the profile and roughness (Sa) of the buccal surface before and after sandblasting application by using a profile gauge (Form Talysurf Intra, Taylor Hobson - AMETEK Inc, Pennsylvania, USA) and a laser interferometer (Talysurf CCl Lite, Taylor Hobson - AMETEK Inc, Pennsylvania, USA), respectively. A qualitative assessment of enamel surface was performed by means of scanning electron microscopy (SEM). For this latter analysis, a sample of each group was randomly chosen so that the sandblasted enamel surfaces could be adequately prepared to be evaluated. The quantitative data were compared by using ANOVA test, followed by post-hoc Tukey\'s test, at a significance level of 5% (P = 0.05). Results: Profile and roughness were found to be more altered as the sandblasting application time increased. With regard to the profile, however, statistically significant differences were found only in Group A (1s) compared to Groups D (7s) and E (10s), as well as in Group B (3s) compared to Group E (10s). With regard to the roughness, statistically significant difference was also observed only in Group E (10s) compared to the other groups. Five SEM images were demonstrated to be very similar to each other, with the conditioning pattern being marked by peaks and valleys, although SEM images of enamel blasted for 1 and 3 seconds showed peaks and valleys in lesser amount. Conclusion: Both loss of dental structure and enamel roughness increased as the time for application of aluminum oxide sandblasting also increased; application of aluminum oxide sandblasting for 1 and 3 seconds produced less loss of enamel structure compared to the 10-second application; more roughness can be obtained with application of aluminum oxide sandblasting for 10 seconds; however, the morphological aspect of the tooth enamel is very similar, regardless of the application time.
138

Análise do comportamento do coeficiente de desgaste nas diferentes camadas dos Dentes de Resina Acrílica / Analysis of the behavior of wear coefficient in the different layers of Acrylic Resin Teeth

Uehara, Priscila Nakasone 08 June 2016 (has links)
O objetivo desse estudo foi analisar o comportamento de desgaste das camadas correspondentes ao esmalte e à dentina. Foram utilizados incisivos centrais superiores de seis modelos comerciais de dentes artificiais para confecção dos corpos de prova (Premium, Magister, Vivodent PE, Biotone, Artiplus IPN e Trilux). O número total de amostras foi igual a cinco para cada marca comercial Para analisar o coeficiente de desgaste dos dentes artificiais o ensaio de desgaste micro-abrasivo foi em função da Distância de deslizamento (S) e da Força normal (N), sob condições de N constante. As crateras de desgaste foram realizadas sem paradas intermediárias para obtenção da evolução do diâmetro da cratera em função do tempo de ensaio. Os tempos de ensaio foram: 5; 8,33 e 11,66 minutos, os pontos para realização dos ensaios foram escolhidos aleatoriamente. Para cada condição de ensaio foram realizadas cinco repetições. As crateras foram analisadas por meio de microscópio óptico e as medições foram realizadas por meio do software ©Leica Microsytems. Para todas as análises, a normalidade da distribuição dos dados e a homogeneidade foram testadas. Análise de Variância (ANOVA) 2-fatores e o Teste de Tukey para comparações múltiplas foram calculados a partir dos valores obtidos no t3. O menor e maior valor obtido de k foram respectivamente k=22,60.10?? (Ar) e k=47,8.10?? (Ma). Para os fatores marca (p=0.0012) e região (p=0.028) as diferenças foram estatisticamente significantes, no entanto para marca x região (p=0.16) não houve diferença significante. De acordo com os resultados apresentados, conclui-se que o comportamento observado do coeficiente de desgaste em todas as amostras, esmalte e dentina, teve como mecanismo o riscamento. Também, foi possível estabelecer diferenças do comportamento ao desgaste dos dentes artificiais de resina acrílica de diferentes marcas comerciais e suas camadas. E o ensaio de micro abrasão com esfera rotativa fixa é apropriado para o estudo de materiais poliméricos utilizados na Odontologia. / The aim of this study was to analyze the wear behavior of the layers of artificial teeth corresponding to the enamel and dentine by means of micro-abrasive wear with \"ballcratering\". Upper central incisors of six artificial teeth commercial brands were used to confection of the test specimens (Premium, Magister, Vivodent PE, Biotone, Artiplus IPN e Trilux). The total number of samples was five to each commercial brand. To analyze the artificial teeth wear coefficient, the micro-abrasive wear testing was performed according to Distance sliding (S) and normal Force (N), under conditions of constant N. The wear craters were made without intermediate stops in order to obtain the evolution of craters diameter in accordance to in the experiment duration. The testing times were: 5; 8,33 and 11,66 minutes, the points to the testing execution were chosen randomly. Three repetitions were used for each testing condition. Craters were analyzed with optical microscopes and measurements were taken with the software ©Leica Microsytems. For all analyses data distribution normality and homogeneity were tested. \"Analysis of Variance\" (ANOVA) 2- factors and Tukey Test to multiple comparisons were calculated from the obtained values in t3. The lowest and biggest values obtained of k were k=22,60.10?? (Ar) and k=47,8.10?? (Ma), respectively. In relation to brand factors (p=0.0012) and region (p=0.028) the differences were statistically significant, however regarding to brand x region (p=0.16) there was no significant difference. According to the results, it can be concluded that the behavior of the wear coefficient in all samples, enamel and dentin presented grooving abrasion. Also, it was possible to observe differences in wear behavior of brands of acrylic resin artificial teeth and its layers. The micro-abrasive wear with \"ball-cratering\" test is appropriate for the study of polymeric materials in Dentistry.
139

Abrasão de ferro fundido cinzento: aplicação a motores automotivos. / Abrasion of gray cast iron: application to automotive engines.

Franco, Luiz Alberto Pereira das Neves 20 October 2015 (has links)
Uma parte significativa das perdas por atrito num motor automotivo resulta da ação de partículas abrasivas. Dentre as fontes possíveis, podem ser citados o próprio meio ambiente - partículas que passam pelo filtro de ar - o desgaste de partes metálicas do motor ou mesmo resíduos de combustão. Essas partículas podem ficar encrustadas em anéis do pistão, ou ficar na interface entre pistão e bloco ou camisa, e são responsáveis por sulcos axiais, na direção do movimento do pistão, observáveis em motores usados. O objetivo deste trabalho foi obter um melhor entendimento dos mecanismos de desgaste relacionados com o sulcamento de camisa/bloco e identificar conjuntos de testes laboratoriais capazes de reproduzi-los sob condições controladas. Amostras de ferro fundido cinzento (FoFo) e de aço AISI 1070 com dureza de matriz próxima daquela encontrada em FoFo (?200HV30) foram submetidas a ensaios de riscamento em tribômetros. Verificou-se que riscos executados com um endentador cônico submetido a cargas na faixa de 20 a 50 mN eram similares aos sulcos observados em camisas ou blocos. Ensaios com outros materiais, como alumínio e latão e mesmo aço de diferentes durezas contribuíram para melhorar o entendimento dos resultados. Não foi observada transição brusca entre mecanismos de abrasão. O cálculo do fator de remoção de material, fab, a partir de perfilometria óptica resultou em valores com dispersão elevada; não foi possível associa-los aos diferentes mecanismos de abrasão observados. Valores obtidos para o coeficiente de atrito no riscamento permitiram fazer uma estimativa inicial de energia gasta nos processos abrasivos do motor. / A significant part of the friction losses in an automotive engine results from the abrasive action of particles. Among possible sources of such particles one can mention the environment - particles that were not retained by the filters - metallic residues from worn parts or even combustion residues. They may be picked up by piston rings and become part of their surfaces or stay loose in the piston/liner interface. Those particles are responsible for axial grooves that are observed in the liners of used engines. The objective of this work was to get a better understanding of the wear mechanisms related to liner/bore grooving and to identify a laboratory testing setup that might reproduce them under controlled conditions. Specimens of Gray Cast Iron (GCI) and of AISI 1070 steel with matrix hardness close to that found in GCI (?200HV30) were submitted to scratch tests in a tribometer. It was found that scratches performed under 20-50 mN indenter load (conical tip) were similar to grooves observed in cylinder liners. Tests with other materials such as aluminum, brass and even steel with different hardness values contributed to a better understanding of the results. No sharp transition between abrasion mechanisms was observed. Calculation of material removal factor fab from optical profilometry resulted in values with a large dispersion; they could not be associated with different abrasion mechanisms. Friction coefficient values obtained from the tests were used to make preliminary estimates of energy consumption due to abrasive processes in the engine.
140

Reciclagem de vidro laminado: utilização na fabricação de isolantes e vernizes com alta resistência à abrasão para pisos de madeira. / Windshield recycling: in the fabrication of isolators and varnishes with high abrasion resistance for wood flooring.

Vargas, Isabella Marini 30 March 2007 (has links)
Neste trabalho apresenta-se uma alternativa para utilização de vidros laminados provenientes de rejeitos industriais ou pós-consumo. Reciclando o vidro laminado, por meio de uma série de moagens, pode-se obter dois tipos de rejeitos: vidros de partículas pequenas (200 e 325 mesh), que não conseguem ser reaproveitados pela indústria vidreira, e filme de poli(vinil butiral) - PVB - impregnado com uma pequena quantidade de carga, que tem como destino os aterros. No presente estudo, esses dois resíduos foram aproveitados na fabricação de vernizes curados por radiação ultravioleta empregados para proteção de pisos de madeira. O filme de PVB foi utilizado na formulação de um isolante, em razão de sua alta flexibilidade e boa aderência à madeira, e o vidro de baixa granulometria foi empregado como carga nos vernizes chamados de alto tráfego para o aumento da resistência à abrasão dos mesmos (propriedade fundamental de vernizes para pisos de madeira). Pelos resultados obtidos, verificou-se que o isolante preparado com o filme de PVB em solução alcoólica e misturado a um monômero acrílico trifuncional, como o trimetilolpropano triacrilato (TMPTA), quando aplicado sobre pisos de madeira, obteve-se bons resultados de aderência, arrancamento e flexibilidade, podendo assim substituir os isolantes utilizados atualmente, produtos com cura por radiação ultravioleta, em base aquosa, e que apresentam alto custo por serem preparados com resinas importadas. Foi observado que quanto maior a quantidade de solução de PVB, melhor a flexibilidade do filme e, conseqüentemente, melhor a resistência ao arrancamento do revestimento. Os vidros de baixa granulometria apresentaram resultados muito satisfatórios quando utilizados como carga nos vernizes de alto tráfego, especialmente ao se combinarem com o óxido de alumínio (carga atualmente utilizada nesses sistemas), aumentando ainda mais a resistência à abrasão dos vernizes e também a estabilidade dos vernizes (quanto à sedimentação e à geleificação). Para todas as combinações de cargas preparadas neste trabalho foram bons os resultados obtidos, podendo-se optar pela utilização daquelas com maior quantidade de vidro, uma vez que este, por tratar-se de um resíduo, torna tais combinações mais econômicas. / The present work features an alternative for the utilization of the windshield after its use. The recycling of the laminated glass, through a series of grindings, make possible to obtain two kinds of materials: glasses of small particles (200 and 325 mesh), that cannot be recovered in the glass industry, and a poly(vinyl butiral) - PVB - sheet impregnated with a small amount of filler, that has as final disposal the sanitary landfill. In this study these two materials were introduced in the formulation of ultraviolet curing varnishes used to the protection of wood flooring. The film of PVB was used in the formulation of a primer, due to its high flexibility and good adherence to the wood, and the glass of low granulometry was used as a filler in the so-called high traffic varnish, to increase the abrasion resistance (main property of these varnishes). The results obtained showed that the primer prepared with the PVB sheet in alcoholic solution, mixed with a trifunctional acrylic monomer, like TMPTA, when applied on wood flooring, obtained good results of adherence, scrape adhesion, flexibility and stability and could substitute the primers used nowadays that are UV curing products, however water based ones, and that has a high cost because of the imported resins that are used in their formulations. It was observed that larger the amount of solution of PVB, better the flexibility of the film and, consequently, better its scrape adhesion. The glasses of low granulometry also presented very satisfactory results when used as fillers in the high traffic varnishes, mainly when in combination with aluminium oxide (filler used in these systems), increasing more the abrasion resistance of the varnishes and also their stability (the sedimentation and geleification have showed better results). To all filler combinations studied in this work the results were good and the best one can be the ones that presented the largest amount of glass, since as a residue, make these combinations more economical.

Page generated in 0.0306 seconds