• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 9
  • 9
  • 9
  • 9
  • 8
  • 2
  • 1
  • 1
  • Tagged with
  • 200
  • 119
  • 68
  • 62
  • 56
  • 47
  • 45
  • 44
  • 39
  • 35
  • 30
  • 29
  • 25
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Desenvolvimento de eletrodos revestidos para depósitos resistentes ao desgaste abrasivo

Perotti, Ana Paula January 2012 (has links)
O desgaste de máquinas e seus componentes têm grande influência econômica em diversos setores da indústria. Diante dessa situação, tem sido feitos estudos visando desenvolver novos materiais e revestimentos que apresentem maior resistência ao desgaste. O revestimento é um dos métodos mais utilizados quando se procura garantir a uma superfície alguma propriedade mecânica que não é intrínseca ao metal base. O objetivo deste trabalho é realizar um estudo comparativo de ligas de diferentes composições químicas, através do desenvolvimento de um consumível para soldagem manual ao arco elétrico a ser aplicado especialmente para o recobrimento de superfícies submetidas ao desgaste abrasivo. Os eletrodos desenvolvidos foram compostos pela combinação de cromo-carbono e tungstênio-carbono misturados em um revestimento base com rutilo-carbonato de cálcio-fluorita, resultando em eletrodos revestidos com sete diferentes composições. A comparação e avaliação da resistência à abrasão foi feita com base nos dados obtidos no ensaio de desgaste abrasivo, segundo a norma ASTM G65-91, e também baseada nos resultados da composição química, microestrutura e análise microestrutural dos revestimentos. Os resultados mostraram que os depósitos com maior resistência ao desgaste abrasivo foram obtidos com eletrodos com as composições contendo carbono e 7% de tungstênio e carbono e 1,5% de cromo. Esses mesmos depósitos foram os que apresentaram valores mais elevados de microdureza, e em sua microestrutura pode-se perceber a formação de maior quantidade de carbonetos. / The wear in machines and equipments is one of the main sources of economic losses. Nowadays many studies have been conducted to develop new materials and coverages to produce wear resistance. The hardfacing is one of most common methods to produce a deposit having properties not intrinsic to that of the base material. The main objective of this work is to study the viability of using different alloys compositions to produce covered electrodes for shielded metal arc welding (SMAW) resistant to abrasive wear. The covered electrodes were produced adding chromiumcarbon and tungsten-carbon to rutile-calcium carbide-fluorite base. Comparison and evaluation of wear resistance of the developed electrodes was based in ASTM G65-91 wear tests, deposit chemical compositions and the resultant microstructures. The results shown that electrodes containing additions of C-W 7 % and C-Cr 1.5 % produced best performance of wear test deposits. These compositions produced deposits containing the higher amounts of carbides and exhibit higher hardness values.
102

Estudo da influência das propriedades relacionadas à superfície e à matriz na resistência à abrasão de concretos para pisos / Study on the influence of properties related to the surface and matrix in the abrasion resistance of concrete floors

Silva, Cristina Vitorino da January 2015 (has links)
O desgaste superficial por abrasão é uma manifestação patológica que decorre do atrito entre partículas secas e a superfície do material, causando uma perda progressiva das camadas mais externas da estrutura. Entender esse mecanismo de deterioração e ainda os parâmetros que influenciam a sua ocorrência são preocupações válidas, visto que ele compromete a durabilidade e a funcionalidade de estruturas, tais como pisos de concreto. Além disso, a correção desta manifestação patológica exige gastos elevados com reparo ou substituição do concreto e, dessa maneira, a necessidade de maiores estudos buscando ações mais efetivas na prática é justificada. Neste particular, estudou-se a influência das propriedades relacionadas à matriz e à superfície na resistência à abrasão dos compósitos. Para tanto, alguns fatores que influenciam na qualidade dos concretos empregados em pisos, como o tipo de cimento (CP IV; CP V-ARI), a relação água/aglomerante (0,40; 0,60), o teor de substituição de sílica ativa (0%; 10%) e o tipo de cura (submersa; caixa aquecida) foram avaliados. Os ensaios adotados para estudar a influência das propriedades de massa no mecanismo de degaste foram os de resistência à compressão uniaxial, resistência à tração na flexão e exsudação. Já os ensaios para verificar a influência das propriedades de superfície na magnitude desse mecanismo foram os de dureza superficial, resistência à abrasão, porosimetria por intrusão de mercúrio, microdureza por indentação, análises em microscópio estereoscópico e a digitalização tridimensional à laser. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento sobre todas as propriedades avaliadas, sendo que o cimento de alta resistência inicial apresentou melhor desempenho em comparação ao cimento pozolânico, considerando uma mesma idade de análise (63 dias). Além disso, verificou-se uma influência estatística significativa da relação a/agl no comportamento dos concretos, onde a relação a/agl 0,6 aumentou os índices de desgaste das amostras em relação as de referência (a/agl 0,4), conforme esperado. Quanto ao tipo de cura, os compósitos curados de forma submersa apresentaram os melhores resultados frente ao desgaste superficial comparando-se àqueles mantidos na cura em caixa aquecida. Finalmente, analisando o teor de substituição de sílica ativa, observou-se que a substituição de 10 % sobre a massa de cimento proporcionou acréscimos estatisticamente significativos na resistência à abrasão das amostras com menor relação a/agl; somando-se a isto, a presença da sílica minimizou o efeito da cura em caixa aquecida na camada superficial das amostras de concreto submetidas ao desgaste. Concluindo, a resistência à abrasão dos concretos mostrou ter uma importante relação não somente com as suas propriedades de massa, mas também com a qualidade da sua camada superficial, uma vez que apresentou forte correlação com as características de superfície avaliadas, como a dureza superficial, a microdureza e a porosimetria ao mercúrio. Além disso, salienta-se que o ensaio de dureza superficial por esclerometria poderia ser adotado como parâmetro para determinação direta da resistência ao desgaste e sugere-se que a exsudação dos pisos de concreto venha a ser o fator principal no controle da qualidade da camada superficial da placa de concreto. / Surface abrasion wear is a pathological manifestation triggered by friction between dried particles and the surface of the material, provoking a progressive loss of the outermost layers. The comprehension of this mechanism of deterioration and also the parameters that influence its occurrence are valid concerns, since it compromises the durability and functionality of structures such as concrete floors. In addition, repair this pathological manifestation or replace the damage concrete require high expenditure. Thus, the necessity of further studies seeking for practical effective actions is justified. In this particular, the aim of this work was to study the influence of properties related to the matrix and the surface of composites on abrasion resistance. For this purpose, some factors that influence the quality of the concrete used in floors, including the cement type (CP IV; CP V-ARI), the water / binder ratio (0.40, 0.60), the replacement content of silica fume (0%, 10%) and the conditions of cure (submerged; heat box) were evaluated. The assays employed in order to study the influence of mass properties on the wear mechanism were the compressive strength, flexural tensile strength and bleeding. As regards to the influence of surface properties on the magnitude of this mechanism, it was verified by testing the surface hardness, abrasion resistance, porosimetry by mercury intrusion, microhardness by indentation, analysis in stereoscopic microscope and three-dimensional laser scanning. The obtained data demonstrated a statistically significant influence of cement type on all assessed properties, with the high early strength cement presenting a better performance as compared to pozzolan cement, considering a similar age of analysis (63 days). Furthermore, there was a statistically significant influence of water / binder ratio on concrete behavior, where the water / binder ratio of 0.6 increased the wear rates of the samples in comparison to the reference (water / binder 0.4), as expected. Regarding to the conditions of cure, the submerged composites showed better results against surface wear as compared to those kept in the heat box. Finally, it was observed that the replacement content of silica fume of 10% on the cement mass provided statistically significant increases in abrasion resistance of samples with lower water / binder ratio. In addition, the presence of silica minimized the effects of curing in a heat box on the surface layer of concrete samples that were submitted to wear. In conclusion, the abrasion resistance of concretes demonstrated an important relationship not only with the mass properties of these structures but also with the quality of their surface layer, since a strong correlation with the evaluated surface features was observed, including surface hardness, microhardness and porosimetry by mercury intrusion. Moreover, it is emphasized that the surface hardness assay by rebound hammer may be used as a parameter for direct determination of wear resistance and it is suggested that bleeding of concrete floors might be the main factor for controlling the surface layer quality of the concrete slab.
103

Estudo comparativo sobre o emprego de 5-fluoruracil a 5% em creme versus sua utilização como agente de peelings superficiais seriados no tratamento do fotoenvelhecimento avançado. / Comparative study on the use of 5 % fluorouracil cream versus its use as superficial peeling agent in the treatment of advanced photoaging

Guimaraes, Carolina Okada Zerbini [UNIFESP] January 2013 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:46:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2013 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Introdução: O 5-fluorouracil (5-FU) e um agente quimioterapico antimetabolito que atua bloqueando a reacao de metilacao do acido deoxiuridilico em acido timidilico, interferindo na sintese do DNA e RNA. A defiCiência de timina provoca desequilibrio no crescimento e morte celular. O uso topico de 5-FU a 5% em creme e aprovado para o tratamento de queratoses actinicas. Outra modalidade de emprego sao os peelings superficiais seriados. Observa-se melhora da textura, rugas e pigmentacao da pele com fotodano avancado. Assim, e util na prevencao das queratoses actinicas e cancer de pele nao-melanoma, com beneficio na aparencia da pele. Objetivos: O objetivo primario foi avaliar a eficacia (clinica e histologica) e a seguranca do 5-FU 5% em creme comparado ao seu uso em peelings seriados no tratamento do fotodano avancado dos antebracos. O objetivo secundario foi avaliar o beneficio estetico na pele fotoenvelhecida relacionado a melhora das alteracoes epidermicas e dermicas, assim como a duracao dos resultados. Metodos: Estudo de intervencao terapeutica, randomizado, comparativo, avaliador-cego, em 32 homens e mulheres, acima de 50 anos, portadores de fotoenvelhecimento moderado a grave dos antebracos. Os esquemas terapeuticos compreenderam o uso do 5- FU 5% em creme, uma vez ao dia, por quatro semanas, num antebraco e a realizacao de quatro peelings de 5-FU seriados semanais no antebraco contralateral. A avaliacao da eficacia foi clinica, atraves de uma escala de fotoenvelhecimento desenvolvida para antebracos, opiniao do paciente e investigador e fotografica cega, por tres observadores. Foram realizadas tres biopsias de pele em cada antebraco (pre, um mes e seis meses postratamentos) e exame histopatologico, pelas coloracoes hematoxilina-eosina e Calleja (fibras elasticas), alem de imuno-histoquimica para avaliar a expressao da proteina p53 epidermica nao selvagem e marcador dermico para procolageno I. A avaliacao de seguranca baseou-se no relato e observacao de eventos adversos. Resultados: Os achados clinicos e histologicos confirmaram os beneficios do 5-FU 5% topico, independentemente da modalidade de uso, na melhora no aspecto geral da pele fotoenvelhecida, reducao do material elastotico da derme. A imuno-histoquimica demonstrou diminuicao da expressao da proteina p53 e aumento da expressao do procolageno I, sem diferencas entre os tratamentos. A avaliacao clinica apos seis meses demonstrou a manutencao dos efeitos observados apos um mes do final dos tratamentos. Os eventos adversos observados, de intensidade leve a moderada e sem diferencas entre os tratamentos, foram: prurido, dor, eritema, xerose, descamacao e crostas. Houve melhor tolerabilidade com a utilizacao dos peelings superficiais seriados. Conclusao: O 5-FU a 5% em creme ou peeling foi eficaz no tratamento do fotodano avancado dos antebracos, promoveu reducao da expressao de p53, e reestruturacao dermica / BV UNIFESP: Teses e dissertações
104

Desenvolvimento de eletrodos revestidos para depósitos resistentes ao desgaste abrasivo

Perotti, Ana Paula January 2012 (has links)
O desgaste de máquinas e seus componentes têm grande influência econômica em diversos setores da indústria. Diante dessa situação, tem sido feitos estudos visando desenvolver novos materiais e revestimentos que apresentem maior resistência ao desgaste. O revestimento é um dos métodos mais utilizados quando se procura garantir a uma superfície alguma propriedade mecânica que não é intrínseca ao metal base. O objetivo deste trabalho é realizar um estudo comparativo de ligas de diferentes composições químicas, através do desenvolvimento de um consumível para soldagem manual ao arco elétrico a ser aplicado especialmente para o recobrimento de superfícies submetidas ao desgaste abrasivo. Os eletrodos desenvolvidos foram compostos pela combinação de cromo-carbono e tungstênio-carbono misturados em um revestimento base com rutilo-carbonato de cálcio-fluorita, resultando em eletrodos revestidos com sete diferentes composições. A comparação e avaliação da resistência à abrasão foi feita com base nos dados obtidos no ensaio de desgaste abrasivo, segundo a norma ASTM G65-91, e também baseada nos resultados da composição química, microestrutura e análise microestrutural dos revestimentos. Os resultados mostraram que os depósitos com maior resistência ao desgaste abrasivo foram obtidos com eletrodos com as composições contendo carbono e 7% de tungstênio e carbono e 1,5% de cromo. Esses mesmos depósitos foram os que apresentaram valores mais elevados de microdureza, e em sua microestrutura pode-se perceber a formação de maior quantidade de carbonetos. / The wear in machines and equipments is one of the main sources of economic losses. Nowadays many studies have been conducted to develop new materials and coverages to produce wear resistance. The hardfacing is one of most common methods to produce a deposit having properties not intrinsic to that of the base material. The main objective of this work is to study the viability of using different alloys compositions to produce covered electrodes for shielded metal arc welding (SMAW) resistant to abrasive wear. The covered electrodes were produced adding chromiumcarbon and tungsten-carbon to rutile-calcium carbide-fluorite base. Comparison and evaluation of wear resistance of the developed electrodes was based in ASTM G65-91 wear tests, deposit chemical compositions and the resultant microstructures. The results shown that electrodes containing additions of C-W 7 % and C-Cr 1.5 % produced best performance of wear test deposits. These compositions produced deposits containing the higher amounts of carbides and exhibit higher hardness values.
105

Uso de técnicas ópticas no monitoramento dos efeitos do laser de Nd:YAG sobre a erosão dentária

Pereira, Daísa de Lima January 2014 (has links)
Orientadora: Profa. Dra. Patricia Aparecida da Ana / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Biomédica, 2014. / As lesões de erosão e abrasao em superfícies dentinárias apresentaram sua prevalencia aumentada nos ultimos anos, o que evidencia a necessidade de estrategias preventivas e do desenvimento de um metodo de diagnostico precoce destas lesoes. Desta maneira, a Biofotonica tem muito a contribuir neste aspecto. Este estudo objetivou verificar a possibilidade de diagnostico inicial e de monitoramento da progressao da erosao e abrasao dentinarias por meio de tecnicas opticas, empregando-se um sistema de tomografia por coerencia optica (OCT) e um sistema de imagens por fluorescencia (SIF), assim como avaliar o potencial do laser de Nd:YAG, quando associado ou nao a aplicacao topica de fluor fosfato acidulado (FFA), na prevencao da perda estrutural promovida pela erosao e abrasao da dentina. Para tal, foi realizado um estudo in vitro em que foram preparados 192 blocos de dentina radicular bovina, os quais foram aleatoriamente distribuidos em quatro grupos experimentais (n = 48): G1- sem tratamento; G2- tratamento com fluor fosfato acidulado (FFA, 1,23% F-, pH = 3,3 . 3,9); G3- irradiacao com laser de Nd:YAG (1064 nm, 0,6 W, 10 Hz, 84,9 J/cm2); G4- aplicacao de FFA, seguida de irradiacao com laser de Nd:YAG. Apos os tratamentos, as amostras foram submetidas a um modelo de desafio de erosao e abrasao por escovacao durante 15 dias, sendo avaliadas por OCT e SIF em 5 momentos distintos: antes e apos os tratamentos, e apos 5, 10 e 15 dias de desafio. A avaliacao morfologica superficial foi efetuada empregando-se microscopia eletronica de varredura (MEV). Por meio da tecnica de OCT, observou-se o desenvolvimento de lesoes de erosao/abrasao de 9,8 } 2,9 ¿Êm de profundidade em apenas 5 dias de desafio nas amostras sem tratamento, enquanto que as amostras irradiadas apresentaram lesoes com profundidade media de 6,0 } 2,7 ¿Êm. Em todo o periodo, observou-se que a irradiacao com laser reduziu significativamente (p = 0,00) o desenvolvimento da erosao dentinaria, totalizando area media de lesao de 14265,7 } 11989,0 ¿Êm2, enquanto que o grupo sem tratamento apresentou area de 34111,5 } 9269,8 ¿Êm2. A aplicacao de FFA nao modificou significativamente (p > 0,05) a area ou profundidade das lesões formadas em nenhum dos tempos de desafio. Foram detectadas alteracoes na fluorescencia da dentina decorrentes dos tratamentos e do desafio empregado, sendo relacionadas principalmente a formacao da camada de esfregaco decorrente da escovacao sobre a dentina, a qual foi evidenciada tambem nas analises por MEV. A irradiacao com laser isoladamente promoveu fusao e ressolidificacao da superficie, enquanto se observou discreta ablacao e exposicao de tubulos dentinarios quando associado a aplicacao de FFA. Desta maneira, foi possivel concluir que a tecnica de OCT possibilita o diagnostico precoce e o monitoramento tanto das areas quanto da profundidade das lesoes de erosao e abrasao formadas na dentina, enquanto que a tecnica de SIF permite a deteccao das modificacoes quimicas oriundas deste processo, tais como a formacao da camada de esfregaco. Ainda assim, pode-se concluir que a irradiacao da dentina com laser de Nd:YAG promove reducao da progressao das lesoes de erosao na dentina, e a associacao com FFA nao apresenta nenhum efeito sobre este processo. / Last years showed an increase in the prevalence of erosion and abrasion lesions on dentin surfaces, highlighting even more the need for preventive strategies and development of early diagnosis methods. Several biophotonic methods could be of great utility for this application. This work has two main objectives. The first one is to evaluate the potential of two optical techniques for initial diagnosis and monitoring of dentin abrasion and erosion, using an Optical Coherence Tomography system (OCT) and a fluorescence imaging system (FIS). The second objective is to characterize the effect of the Nd:YAG laser, with or without topical application of acidulated phosphate fluoride (APF), for prevention of structural loss by erosion and abrasion of the dentin. An in vitro study involved 192 blocks of bovine root dentine, which were randomly distributed in four experimental groups (n = 48): G1 without treatment; G2 treatment with acidulated phosphate fluoride (APF, F 1.23%, pH = 3.3 to 3.9); G3 irradiation with Nd: YAG laser (1064 nm, 0.6 W, 10 Hz, 84.9 J / cm2); G4 application of APF followed by irradiation with Nd:YAG laser. After these protocols, all samples were subjected to a model of erosion and abrasion brushing for 15 days, then evaluated by OCT and FIS at 5 different time points: before treatment, after treatment, after 5, 10 and 15 days of erosion/abrasion. Morphological evaluation of the surface was performed using scanning electron microscopy (SEM). After 5 days of erosion/abrasion, the depth of the lesions on untreated samples was measured at 9.8 ± 2.9 microns using OCT, while the irradiated samples (G3) showed an average depth of 6.0 ± 2.7 microns. Throughout the period, it was observed that the laser irradiation significantly reduced the development of dentine erosion (p = 0.00): the average total lesion area was 14265.7 ± 11989.0 ìm2, while the untreated group had an average total area of 34111.5 ± 9269.8 ìm2. The application of APF did not significantly modify the area nor the depth of the lesions formed at any of the time points (p> 0.05). Dentin fluorescence was modified by the treatments and the erosion/abrasion protocol due to the creation of smear layer by brushing on dentin, which was also showed by SEM analysis. Laser irradiation alone promoted melting and re-solidification of the surface, while discrete ablation and exposure of dentinal tubules appeared when laser irradiation was associated with APF application. This study has shown that OCT allows early diagnosis and monitoring of the area as well as the depth of dentin lesions, while FIS is able to detect chemical modifications such as the formation of a smear layer. Furthermore, it can be concluded that dentin irradiation by Nd:YAG laser decreases the erosion process of dentin lesions, while the use of APF has no effect on this process.
106

Desgaste por abrasão de poliuretano utilizado na indústria mínero-metalúrgica

Cruz, Dennis Coelho January 2006 (has links)
Submitted by Stéfany Moreira (stemellra@yahoo.com.br) on 2013-03-07T17:01:16Z No. of bitstreams: 1 DISSERTAÇÃO_DesgasteAbrasãoPoliuretano.pdf: 4181245 bytes, checksum: 2a694a651ae28e23782ca3732c52d3be (MD5) / Approved for entry into archive by Neide Nativa (neide@sisbin.ufop.br) on 2013-03-13T21:01:55Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_DesgasteAbrasãoPoliuretano.pdf: 4181245 bytes, checksum: 2a694a651ae28e23782ca3732c52d3be (MD5) / Made available in DSpace on 2013-03-13T21:01:55Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_DesgasteAbrasãoPoliuretano.pdf: 4181245 bytes, checksum: 2a694a651ae28e23782ca3732c52d3be (MD5) Previous issue date: 2006 / A utilização do poliuretano na indústria mineral está em processo de expansão de mercado. Na sua principal utilização, raspadores e limpadores de correias transportadoras, esse polímero tem mostrado uma boa resistência ao desgaste quando efetua a limpeza de correias transportadoras. Esse trabalho é uma tentativa de se conhecer os diversos mecanismos de desgaste através do ensaio de abrasão, buscando correlacioná-los com situações típicas como, por exemplo, a lâmina dos raspadores. Os resultados dos experimentos permitiram-nos evidenciar as propriedades dos poliuretanos sob o ponto de vista do desgaste, bem como sugeriram-nos estabelecer uma hierarquia para os diferentes poliuretanos estudados. __________________________________________________________________________________________ / ABSTRACT: The use of polyurethane in the mineral industry is in process of market expansion. In its main use, belt cleaners and scraper, this polymer has shown a good wear resistance when it effects the cleanness of conveyor belt. This work is an attempt of if knowing the different wear mechanisms through the abrasion test searching to correlate them with typical situations such as the blade of the belt cleaners. The results of the experiments had allowed to evidence the properties of polyurethane under the point of view of the wear, as well as had suggested to establish a hierarchy for the different studied polyurethane.
107

Influência da técnica de preparo cavitário na microinfiltração marginal em restaurações de dentes decíduos

Silva, Vlamir Oliveira da [UNESP] 06 December 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-12-06Bitstream added on 2014-06-13T19:43:59Z : No. of bitstreams: 1 silva_vo_dr_arafo.pdf: 540803 bytes, checksum: 7326794dd51a361dd48b2e7c4b355170 (MD5) / O objetivo desse trabalho foi avaliar a influência da forma do preparo cavitário na microinfiltração marginal em restaurações em dentes decíduos. Foram preparadas canaletas medindo 2,0 mm nas faces vestibular e lingual de molares decíduos que foram divididas aleatoriamente em 3 grupos de acordo com a técnica de preparo cavitário: Grupo I - alta rotação associado à ponta diamantada; Grupo II - sistema de abrasão a ar; e Grupo III - laser Er:YAG. Após o condicionamento com ácido fosfórico por 15 segundos, foi utilizado o adesivo Single Bond (3M) e a resina Filtek Flow (3M) para restaurar as canaletas. Os espécimes foram então mantidos em estufa a 37ºC por 6 dias, termociclados (500 ciclos com temperatura variando entre 5 e 55ºC), isolados e colocados em solução de fucsina básica à 0,5% durante 24 horas. Após serem seccionados a microinfiltração foi avaliada em microscópio ótico ligado a uma câmera de vídeo com 10 X de aumento. Para se avaliar a forma das cavidades medimos os ângulos oclusal, cervical e de abertura das cavidades, bem como a largura e a profundidade das mesmas por meio de fotomicrografias obtidas em MEV. Os resultados demonstraram semelhança estatística entre as larguras dos preparos cavitários, porém os ângulos oclusal, cervical e de abertura das cavidades apresentaram-se diferentes estatisticamente e que não houve microinfiltração marginal em nenhum dos grupos avaliados e que a diferença na forma de preparo das cavidades não influenciou na microinfiltração marginal dos espécimes estudados. / The aim of this research was the evaluation of the cavity prepare technique on the marginal microleakage in deciduous teeth. Cavities measuring 2.0 mm were prepared on the buccal and lingual faces and were divided into three groups according to the cavity prepare technique: Group I - High speed associated to diamond bur; Group II - air abrasion system; and Group III - Er:YAG laser. After the phosphoric acid etching for 15 seconds, the Single Bond (3M) adhesive and te Filtek Flow (3M) were used for the restoration of the cavities. Then the sample was stored at 37ºC for 6 days, termocycled (500 cycles with temperature varying from 5 to 55º C), isolated and immersed in a 0.5% funcsin solution for 24 hours. After being sectioned the microleakage was examined with a magnification optical microscope connected to a color video camera. In order to evaluate the shape of the cavities the occlusal, cervical and cavity opening angles were measured, as well as the width and depth of then, using SEM photographs. The results showed that there was no marginal microleakage in any of the evaluated groups and that the difference in the cavity shape did not influence the marginal infiltration on the studied samples.
108

Efeito de protocolos de jateamento na resistência à flexão e transformação de fase cristalina em cerâmicas de Y-TZP

Turci, Priscilla Cristoforides Pereira [UNESP] 24 April 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:49Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-24. Added 1 bitstream(s) on 2015-06-18T12:47:01Z : No. of bitstreams: 1 000829403.pdf: 678241 bytes, checksum: e51ad21d05ccf2fa4a8b92a572ce754a (MD5) / O objetivo deste estudo foi avaliar o efeito de diferentes protocolos de jateamento na resistência à flexão biaxial e transformação de fase cristalina de cerâmica policristalina de Y-TZP. Foram confeccionados 740 discos de zircônia estabilizada parcialmente por ítrio - Cercon®Zirconia (DENTSPLY Ceramco, EUA) e In Ceram 2000 YZ cubes (Vita Zahnfabrik, Alemanha) segundo a norma ISO 6872 (15 mm diâmetro x 2 mm espessura). As amostras foram jateadas com partículas de óxido de alumínio (30 μm) revestido por sílica (RocatecSoft - 3M ESPE) e divididas em 74 grupos (n = 10), incluindo-se os grupos controle (ausência de jateamento)(n = 10) para cada cerâmica, de acordo com os fatores: pressão de jateamento (2, 3 e 4 bar); ângulo formado entre a ponta do jateador e a superfície da cerâmica (45º, 60º, 90º); distância do microjateador à cerâmica (5 e 10 mm) e tempo de jateamento (15 s e 20 s). Foi realizado teste de resistência à flexão biaxial em máquina de ensaio universal (1 mm/min, 1000 kg). Os dados (MPa) foram submetidos a análise de variância e ao teste de Duncan. Parte das amostras (n=3) foram submetidas à difração por raios-X (DRX) para quantificação das fases cristalinas e à microcopia eletrônica de varredura (MEV) para análise da topografia superficial. Pressão (p = 0,00) afetou significativamente os resultados, porém tempo (p = 0,49), distância (p = 0,46) e angulação (p = 0,13) não afetaram a Cercon. Já para Vita YZ, a pressão (p = 0,00) foi estatisticamente significante, porém tempo (p=0,66), distância (p = 0,70) e angulação (p=0,14) não foram. Fase monoclínica foi encontrada nos grupos da Cercon (0 a 11%), enquanto para Vita YZ, nenhuma fase foi encontrada. Para Vita YZ, a pressão 3 bar teve maior resistência à flexão biaxial e 4 bar apresentou menor valor. Angulação de 45° associado a 2 bar foi a melhor combinação (1012,21 ± 108,36 MPa)... / The aim of this study was to evaluate the effect of different sandblasting protocols on biaxial flexural strength and crystalline phase transformation in Y - TZP ceramic. 740 discs of Yttria-Partially-Stabilized Zirconia were made - Cercon ® Zirconia (DENTSPLY Ceramco, USA) and In Ceram 2000 YZ cubes (Vita Zahnfabrik, Germany) according to the standards of ISO 6872 (15 mm diameter x 2 mm thick) . The samples were sandblasted with aluminum oxide - coated silica 30 μm (Rocatec Soft - 3M ESPE ) and divided into 74 groups (n = 10 ) , according: pressure (2, 3 and 4 bar) ; nozzle angle (45°, 60°, 90°); nozzle distance (5 and 10 mm) and time (15 s and 20 s) . The biaxial flexural strength on universal testing machine (1mm/min, 1,000 kg) was performed. Data (MPa) were submitted to ANOVA and to Duncan's test (α = 0.05). Samples (n = 2) were subjected to X- ray diffraction to quantify crystalline phases. Pressure (p = 0.00) significantly affected the results, but deposition time (p = 0.49), nozzle distance (p = 0.46) and nozzle angles (p=0.13) did not affect to Cercon ceramic. Pressure (p = 0.00) affected significantly the results to Vita YZ, but deposition time (p = 0.66), nozzle distance (p = 0.70) and nozzle angles (p = 0.14) did not affect. Some monoclinical phase was achieved in Cercon groups (0 a 11%) and none for Vita YZ. For Vita YZ ceramic, 3 bar pressure had the biggest flexural strength value and 4 bar was the worst one and angle 45° associated to 2 bar were the best combination (1012.21 ± 108.36 MPa) compared to 4 bar (556.65 ± 117.41 MPa) (p < 0.001). EDS analysis demonstrated regular superficial grains. SEM images indicated grain size of 0.712 μm (Vita YZ), and 0.705 μm (Cercon). The Cercon density was 98% compared to the theoretical density of zirconia, while VITA YZ was 99%
109

Análise in situ da irradiação com laser de Er:YAG no controle da progressão de lesões de erosão e abrasão do esmalte dental / In situ analysis of Er:YAG laser irradiation to control the progression of erosive and abrasive lesions on tooth enamel

Renata Siqueira Scatolin 06 February 2015 (has links)
Este estudo, composto por 2 experimentos in situ, teve como objetivo avaliar o efeito do laser de Er:YAG no controle da progressão de lesões de erosão e abrasão no esmalte dental. Incisivos bovinos foram seccionados (5x3x2,5mm), planificados e polidos. Os fragmentos de esmalte (KHN=330±10%) tiveram parte da superfície coberta com resina composta (área de referência), e posteriormente foram submetidos à formação de lesões erosivas com ácido cítrico 1% (pH = 2,3), 5 minutos, 2x/dia, durante 2 dias. No primeiro experimento, 56 espécimes foram divididos em dois grupos de acordo com o tratamento de superfície: irradiados com laser de Er:YAG (5,2J/cm2, 2Hz, 85mJ, 10s) e não irradiados, e subdivididos de acordo com o tipo de desgaste: erosivos (ácido cítrico) e não erosivos (água deionizada). A realização dos desafios foi realizada através da imersão dos dispositivos em 100mL de ácido cítrico ou água deionizada, 3x/dia, de maneira alternada e independente. O desgaste do esmalte foi determinado por um perfilômetro óptico 3D após: formação inicial da lesão erosiva, tratamento da superfície e fase intraoral. A avaliação de desgaste foi verificada por meio de três leituras de cada área em relação a área de referência. Os dados foram analizados através da análise de variância (ANOVA) e do teste Tukey. No primeiro experimento quando utilizou-se água deionizada (desafios não erosivos) na fase intraoral, os espécimes apresentaram menores valores de desgaste comparados aos grupos que foram erodidos, independentemente de terem sido irradiados ou não com laser de Er:YAG. No entanto, quando erodidos na fase intraoral, o grupo irradiado com laser de Er:YAG não diferiu do grupo não irradiado. O desgaste do esmalte foi avaliado qualitativamente por microscopia eletrônica de varredura em 3 espécimes de cada grupo. No segundo experimento, 48 espécimes foram divididos em dois grupos de acordo com o tratamento de superfície: irradiados com laser de Er:YAG (5,2 J/cm2, 2Hz, 85mJ, 10s) e não irradiados, e subdivididos de acordo com o tipo de desgaste: erosivos (ácido cítrico) e erosivos associado a abrasão (ácido cítrico e escovação). A realização dos desafios, foi realizada através da imersão dos dispositivos em 100mL de ácido cítrico e imersão em ácido cítrico+escovação, de cada um dos lados do dispositivo, 3x/dia. A análises de perfilometria e microscopia eletrônica de varredura foram realizadas como descritas nos procedimentos do primeiro experimento. Os dados obtidos no segundo experimento foram submetidos à análise estatística de forma separada e independente do primeiro experimento, utilizando o teste Kruskal- Wallis e o teste Mann-Whitney. Os resultados deste segundo experimento mostraram que após os desafios erosivos e abrasivos, o grupo que foi irradiado com laser de Er:YAG apresentou menores valores de desgaste quando comparados com o grupo que não foi irradiado. O grupo que sofreu apenas erosão e foi irradiado com laser de Er:YAG não diferiu significativamente quanto aos valores de desgaste do grupo não irradiado. Assim, pode-se concluir que o laser de Er:YAG não controlou o desgaste do esmalte quando submetidos apenas a desafios erosivos, porém, foi capaz de controlar o desgaste do esmalte quando submetidos a processos abrasivos subsequentes. / This study, composed of two in situ experiment, evaluated the effect of Er:YAG laser irradiation to control the progression of erosive and abrasive lesions on enamel. Bovine incisors were sectioned (5x3x2.5mm), flattened and polished. The enamel slabs (KHN = 330 ± 10%) with one fourth of the surface covered with resin composite (reference area) were submitted to initial erosion-like lesion formation with 1% citric acid (pH 2,3), 5 min, 2x/day for 2 days. In the first experiment, 56 slabs were divided into two groups according to the surface treatment: irradiated with Er:YAG laser (5,2 J / cm2, 2 Hz, 85 mJ, 10 s) and non-irradiated, and subdivided according to the type of wear: erosive (citric acid) and non-erosive (deionized water). The challenges were performed by immersing the devices in 100 mL citric acid or deionized water, 3x/day, randomly and independently. Enamel loss was determined by an optical 3D profilometer after: initial erosion, surface treatment and intraoral phase. The average of structure loss was verified by three readings of each experimental area comparing with reference area. Data was analyzed using the analysis of variance (ANOVA) and Tukeys test. In the first experiment, when used deionized water (non-erosive challenges) in intraoral phase, the specimens showed lower values of wear compared with the groups that were eroded with citric acid, whether irradiated or non-irradiated with Er:YAG laser. When erosion with citric acid was performed, Er:YAG laser didnt differ from non-irradiated group. The enamel wear was assessed qualitatively by scanning electron microscopy in 3 specimens of each group. In the second experiment, 48 slabs were divided into two groups according to the surface treatment: irradiated with Er:YAG laser (5,2 J/cm2, 2 Hz, 85 mJ, 10 s) and nonirradiated and subdivided according to the type of wear: erosive (citric acid) and erosive associated with abrasive (citric acid + brushing). The challenges were performed by immersing the devices in 100 mL citric acid and citric acid+brushing on each side of the device. The profilometry and scanning electronic microscopy analysis were performed as described in the procedures of the first experiment. The data from the second study were statistically analyzed separately and independently of the first experiment, using the Kruskal-Wallis test and the Mann-Whitney test.The results of the second experiment showed that after erosive and abrasive challenges, the group irradiated with Er:YAG laser showed lower structure loss than nonirradiated group. The group that suffered erosion and was irradiated, did not differ significantly from the non-irradiated group. Thus, it can be concluded the Er:YAG laser irradiation didnt control the enamel loss when submitted to erosive challenges, however, was able to control the enamel loss when submitted to abrasive challenges.
110

Estudo da resistência à abrasão e erosão do aço ASTM A106GrB submetido a diferentes condições de tempo e temperaturas de esferoidização

Felipe, Gabrieli Borges Ugioni January 2017 (has links)
Dissertação de Mestrado apresentado ao Programa de Pós-Graduação em Ciência e Engenharia de Materiais, da Universidade do Extremo Sul Catarinense - UNESC, como requisito à obtenção do título de Mestre em Ciência e Engenharia de Materiais. / Um dos problemas verificados em trocadores de calor, fabricados em tubos de aço carbono, que trabalham em temperaturas elevadas é a degradação causada por processos erosivos e abrasivos, gerados pela ação de cinzas oriundas da queima de carvão, com aproximadamente 42% de cinzas. Um dos fatores que contribuem para a degradação do material são as mudanças microestruturais, como a esferoidização da cementita perlítica lamelar, quantidade de carbonetos e tamanho médio das partículas. O objetivo desse trabalho foi avaliar o efeito da esferoidização nas temperaturas de 530°C, 630°C e 700°C nos tempos de 50h, 100h e 200h, nas condições de desgaste erosivo a quente, simulando a temperatura real de trabalho (450°C) e abrasivo no aço ASTM A106. Avaliou-se a variação do volume, as microestruturas esferoidizadas, o tamanho de grão e a resistência mecânica a partir da microdureza. As amostras com maior nível de esferoidização, obtidas nas temperaturas de 700°C em tempos de 50 horas e apresentaram maior redução de dureza, o que resultou em maiores perdas de massa. De forma geral, com o aumento da esferoidização, há redução da dureza e aumento do desgaste erosivo, porém com gradativa redução da taxa de desgaste. Isto possivelmente decorre do aumento da ductilidade/tenacidade da matriz, a qual retarda o processo de fragmentação (debris) da superfície do aço ASTM A106 durante o processo erosivo à quente.

Page generated in 0.2542 seconds