• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 1
  • Tagged with
  • 57
  • 57
  • 57
  • 57
  • 57
  • 46
  • 46
  • 45
  • 14
  • 12
  • 12
  • 11
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Batista, Alex Domingues 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
52

A derivatização na determinação de proteínas e aminoácidos em fluidos biológicos / Derivatization in the determination of proteins and amino acids in biological fluids

Orlando Guarilha Junior 06 June 2003 (has links)
No presente trabalho são apresentadas análises de amostras de proteínas totais e aminoácidos empregando-se os reagentes p-benzoquinona e tetraamin cobre (II). No caso do reagente p-benzoquinona, as análises foram feitas através de um sistema inédito em fluxo, no qual a mistura reacional passava através de um reator composto de um tubo capilar de aço inoxidável aquecido num banho de glicerina. Os derivados formados passavam através de uma cela de fluxo acoplada a um espectrofotômetro, onde eram feitas as leituras das absorbâncias. Este método se mostrou mais rápido em relação àquele feito em banho-maria. A utilização de um sistema de análise por injeção em fluxo (FIA) com o reagente tetraamin cobre (II), permitiu que as análises fossem feitas de forma rápida, a baixo custo e com a vantagem de não necessitarem de aquecimento, como no caso da p-benzoquinona. Os resultados das análises de amostras de albumina humana obtidos em ambos os métodos acima apresentaram boa concordância quando comparados àqueles obtidos pelo método Kjeldahl para as mesmas amostras. / This work describes two methods for analysis of total proteins and aminoacids using both p-benzoquinone (PBQ) and tetraamin copper (II) reagents. With the p-benzoquinone reagent the method was performed by an original flow system made with stainless steel capillary tubing, conveniently heated into a glycerin bath, where the reactional mixture travels in its way to the detector. The derivate products are carried out to a flow cell adjusted to a spectrophotometer where the absorbances are measured. This method was efficient, with a fair cost, and providing results very faster than in the batch mode of operation. The second method, using the tetraamin copper (II) reagent, was performed by a common flow injection system (FIA). When compared with the PBQ method, the FIA tetramin copper (II) method was also rapid, efficient, with a fair cost and with the great advantage of simplicity, once it is performed at room temperature. The results obtained with human albumine samples using both methods are in agreement with those ones obtained by the Kjeldahl method for the same samples.
53

Estratégias para aumento de sensibilidade e seletividade de separações cromatográficas em sistemas de análises em fluxo / Strategies to improve sensitivity and selectivity of chromatographic separations in flow analysis systems

Alex Domingues Batista 10 December 2014 (has links)
A introdução de separações cromatográficas expandiu a aplicabilidade de sistemas de análises em fluxo. No entanto, a seletividade e sensibilidade de procedimentos são restritos devido à escassa disponibilidade de fases estacionárias que operam a baixas pressões. Sendo assim, foram desenvolvidos quatro procedimentos analíticos visando a melhoria destes aspectos. A primeira proposta explorou pioneiramente colunas de núcleo fundido em sistemas de análises por injeção em fluxo. A separação de metil, etil e propil parabenos foi selecionada com aplicação. As eficiências cromatográficas de quatro colunas (C18, RPamida, F5 e fenil-hexil) foram avaliadas criticamente. Acetonitrila e uma solução de ácido fosfórico pH 2,5 foram utilizadas como fase móvel. A fase RP-amida apresentou melhor desempenho com a separação dos três analitos em 8,0 min, com resoluções > 1,72, simetrias de pico < 1,66, LOD entre 0,12 e 0,39 mg L-1, resposta linear até 5,0 mg L-1 (r > 0,996) e CV para altura dos picos < 3,5 % (n=10). O procedimento foi aplicado à determinação de parabenos em produtos de cuidados pessoais e os resultados concordaram com o procedimento de referência a 95% de confiança. Um procedimento envolvendo o acoplamento de extração em fase sólida (SPE) a um sistema de cromatografia por injeção sequencial (SIC) foi proposto para pré-concentração e separação de oito sulfonamidas. A fase estacionária pentafluorofenilpropil foi selecionada após comparação crítica da eficiência apresentada por três colunas de núcleo fundido e duas colunas de fases monolíticas. Acetonitrila e tampão fosfato (pH 5,0) foram utilizados como fase. Fatores de enriquecimento de até 39,2 foram alcançados com volume de amostra de 500 ?L. O procedimento apresentou tempo de análise < 10,5 min, resoluções > 1,83 com simetrias de pico <= 1,52, LOD entre 4,9 e 27 ?g L-1, faixa de resposta linear entre 30,0 e 1000,0 ?g L-1 (r > 0,997) e CV da altura dos picos, 2,9% (n=6). Um procedimento empregando fase estacionária micelar foi desenvolvido para determinação de melamina em leite. A fase móvel foi composta por uma solução aquosa de dodecil sulfato de sódio (SDS) e 1-propanol (92,5:7,5 v/v). O procedimento de preparo de amostra foi implementado em linha pela diluição da amostra com SDS. Resposta linear foi observada entre 2,0 e 6,0 mg L-1 de melamina com LOD estimado em 0,6 mg L-1 e CV da altura dos picos de 2,9% (n=6). Os resultados para diferentes amostras de leite foram concordantes com aqueles obtidos pelo procedimento cromatográfico de referência em um nível de 95% de confiança. Uma estratégia envolvendo pré-concentração on-column de parabenos em um sistema SIC foi proposta. Resposta linear foi observada entre 0,25 e 1,00 ?g mL-1 (r >= 0,999) e LODs estimados entre 40 e 60 ng mL-1. Tempos de retenção e altura dos picos apresentaram CV < 2,1%. Fatores de enriquecimento entre 30,0 e 34,8 foram alcançados. As estratégias propostas são viáveis para melhoria de seletividade e sensibilidade de separações cromatográficas em sistemas de análises em fluxo, além de apresentarem vantagens frente a procedimentos análogos na literatura / The introduction of chromatographic separations expanded the applicability of flow systems. However, selectivity and sensitivity of the procedures are limited due the poor options of stationary phases available for low-pressure. Therefore, four procedures were developed aiming the improvement of these aspects. The first proposal exploited pioneered fused-core columns in a flow injection analysis system. The separation of methyl, ethyl and propel parabens was selected as an application. The chromatographic efficiency of four columns (C18, RP-amide, F5 and fenyl-hexyl) were crítically evaluated. Acetonitrile and a phosphoric acid solution at pH 2.5 were used as mobile phase at different proportions for each column. The RP-amide phase presented the best performance by separating the analytes in 8.0 min with resolution > 1.72, peak symmetry < 1.66, LOD between 0.12-0.39 mg L-1, linear response range up to 5.0 mg L-1 (r > 0.996) and coefficients of variation of peak heights < 3.5% (n=10). The procedure was applied to parabens determination in personal care products and the results agreed with the HPLC reference procedure at the 95% confidence level. A procedure coupling solid phase extraction (SPE) to a sequential injection chromatography (SIC) was proposed for preconcentration and separation of eight sulfonamides. The pentafluorophenylpropyl (F5) phase was selected after a critical comparison of the performance achieved by three fused-core columns and two monolithic columns. Acetonitrile and acetate buffer pH 5.0 were used as mobile phase. Enrichment factors up to 39.2 were achieved with a 500 ?L sample volume. The developed procedure showed analysis time < 10.5 min, resolutions > 1.83 with peak symmetry <= 1.52, LODs between 4.9 and 27 ?g L-1, linear response ranges from 30.0 to 1000.0 ?g L-1 (r > 0.997) and CV of peak heights < 2.9% (n=6). Micelar chromatography was for the first time exploited in SIC and the performance was demonstrated by determination of melamine in milk. Mobile phase was composed by a sodium dodecyl sulfate (SDS) solution and propanol (92.5:7.5). The sample pretreatment procedure was on-line implemented by dilution of the sample with SDS. A linear response was observed within 2.0 and 6.0 mg L-1 of melamine with a LOD estimated at 0.6 mg L-1 and coefficients of variation at 2.9% (n=6). Results for different milk samples agreed with those obtained by high performance liquid chromatography at the 95% confidence level. A procedure involved on-column preconcentration of parabens in a SIC system was based on the injection of relatively high volume of an aqueous sample in a reversed-phase column. After preconcentration, a suitable mobile phase was inserted to perform chromatographic separation (acetonitrile/phosphoric acid pH 2.5 (75:25, v/v)). A linear response was achieved from 0.25 to 1.00 ?g mL-1 (r > 0.999) and LOD estimated within 40 and 80 ng mL-1. Coefficients of variation for retention time and peak heights were below 2.1%. Enrichment factors within 30.0 and 34.8 were achieved. The proposed strategies are feasible for improving selectivity and sensitivity of chromatographic separations in flow analysis systems, besides having advantages compared to similar procedures in the literature
54

Construção, caracterização e aplicação analítica de microdispositivos enzimáticos

Cerqueira, Marcos Rodrigues Facchini 09 September 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-21T18:21:21Z No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-22T12:39:49Z (GMT) No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) / Made available in DSpace on 2017-03-22T12:39:49Z (GMT). No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) Previous issue date: 2016-09-09 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O foco deste trabalho foi o desenvolvimento e aplicação de microreatores enzimáticos, visando sua aplicação em sistemas de análise por injeção em fluxo. Em cima disso, dois substratos poliméricos foram utilizados para a avaliação de imobilização enzimática: um à base de poli (metil metacrilato) (PMMA) e outro em uma resina do éter diglicídico do bisfenol-A (BADGE). Uma impressora à laser de CO2 foi utilizada para confeccionar os dispositivos nas dimensões desejadas. Para o sucesso da imobilização, os sistemas foram previamente tratados com polietilenoimina (PEI) visando a introdução de grupamentos funcionais reativos na superfície dos materiais de partida. Num primeiro estudo, baseado na modificação de PMMA, a ativação do material foi conseguida após tratamento dos microcanais com PEI em meio de dimetilsulfóxido (DMSO). Já no segundo caso o tratamento com PEI envolveu a simples mistura mecânica dos materiais, objetivando a cura da resina empregada. Após a ativação dos materiais com PEI, as enzimas foram imobilizadas após passagem de uma mistura de glutaraldeído (um agente espaçador) e as enzimas. Dentre as enzimas estudadas estão a glicose oxidase (GOx), a ascorbato-oxidase (AAO), a catalase (CAT), a glutamato dehidrogenase (GDH), além de um sistema híbrido baseado na imobilização simultânea das enzimas glicose oxidase (GOx) e horseradish peroxidase (HPR). A caracterização dos sistemas desenvolvidos foi feita primordialmente por meio da espectroscopia Raman. Além disso, a aplicação de alguns dos sistemas frente a amostras reais e o cálculo de parâmetros cinéticos e operacionais dos microreatores confeccionados foram reralizados. Essas avaliações foram feitas baseadas em sistemas de detecção desenvolvidos no laboratório por técnicas eletroquímicas e por espectroscopia no visível. Como grande benefício dos sistemas desenvolvidos, podem ser destacados a velocidade e a simplicidade de implementação do processo de imobilização e operação. / The focus of this work is the development and application of enzymatic microreactors aiming their application through flow injection analysis systems. On top of that, two polymeric substrates were used for the evaluation of enzyme immobilization: one based on poly (methyl methacrylate) (PMMA) and another baed on a bisphenol-A diglycidyl ether resin (BADGE). A CO2 laser printer was used to fabricate the devices at the desired dimensions. For the success of the immobilization systems have been pretreated with polyethyleneimine (PEI) in order to introduce reactive functional groups on the surface of the starting materials. In a first study, based on PMMA modification, the activation of the material was achieved after treating microchannels with PEI in dimethylsulfoxide (DMSO). In the second case, treatment with PEI involved simply a mechanical mixture of the two materials, in order to cure the resin. After activation of materials with PEI, the enzymes were immobilized after passage of a mixture of glutaraldehyde (a spacer agent) and enzymes. Among the enzymes studied are glucose oxidase (GOx), ascorbate oxidase (AAO), catalase (CAT), dehydrogenase glutamate (GDH), and a hybrid system based on the simultaneous immobilization of the enzymes glucose oxidase (GOx) and horseradish peroxidase (HPR). The characterization of the developed systems was primarily done by Raman spectroscopy. Moreover, application of some of the proposed systems to real samples and calculation of kinetic and operational parameters are presented during the study. These evaluations were made with detection systems based on electrochemical and visible spectroscopy techniques, all developed at the laboratory. One great benefit of the developed systems, are the speed and simplicity of implementation the immobilization process and operation of the devices.
55

Preparação de hidróxidos mistos nanoestruturados de níquel/cobalto e desenvolvimento de sensores FIA amperométricos / Preparation of nanostructured nickel/cobalt mixed hydroxides and development of FIA amperometric sensors

Martins, Paulo Roberto 21 March 2012 (has links)
Nesta tese foram desenvolvidos sensores amperométricos baseados em porfirinas supramoleculares e hidróxido de níquel nanoestruturado e estabilizado na fase alfa, bem como novos materiais baseados em hidróxidos mistos de níquel e cobalto nanoetruturados e estabilizados na fase alfa. Também, um analisador FIA amperométrico, foi desenvolvido em colaboração com o Laboratório de Instrumentação Analítica do IQ-USP, para a determinação e quantificação de SO2 livre em amostras reais, como vinhos, águas de coco e sucos de frutas. Os sensores amperométricos baseados em porfirinas supramoleculares foram empregados na determinação de SO2 livre, presente em sucos de frutas e águas de coco, utilizando um sistema FIA amperométrico. O sistema FIA amperométrico foi constituído de um injetor manual, uma cela amperométrica em fluxo integrada a uma unidade de difusão de gases e um fluxo de uma solução de ácido sulfúrico e de uma solução de eletrólito. Possíveis interferentes como ácido ascórbico, catecol, glicose e benzoato de sódio foram avaliados antes de iniciar as análises das amostras reais. Os resultados das análises foram comparados com o método oficial Monier-Williams. Os níveis de SO2 livre encontrados nas amostras estavam de acordo com o que é preconizado pela Legislação Brasileira. Os eletrodos de FTO, modificados com hidróxido de níquel estabilizado na fase alfa, foram utilizados como sensores amperométricos para a determinação de glicose, usando um sistema FIA amperométrico. Estes sensores apresentaram excelentes respostas lineares em concentrações inferiores a 100 &#181;M. Ainda estes sensores têm apresentado uma sensibilidade específica muito elevada para a glicose, provavelmente associada com a sua natureza nanoestruturada, e consequêntemente sua área superficial aumentada. No entanto o eletrodo modificado apresentou uma tendência de mudar de fase, da fase meta-estável alfa para a fase termodinamicamente estável beta, com o aumento da concentração de glicose. Novos materiais baseados em hidróxidos mistos de níquel e cobalto estabilizados na fase alfa também foram desenvolvidos. A partir de técnicas como difratometria de raio-x e Microbalança Eletroquímica de Cristal de Quartzo (MECQ) foi possível determinar a fase polimórfica dos materiais. Técnicas como AFM e MEV demonstraram que estes materiais são formados por nanopartículas com tamanhos de 5 nm. Estes nanomateriais apresentaram uma maior quantidade de carga específica, em comparação com o hidróxido de níquel puro. E por último um analisador FIA amperométrico automatizado foi desenvolvido para a realização de análises de SO2 livre em amostras líquidas. Este analisador é composto por reservatórios de soluções, sistema de amostragem, sistema de propulsão das soluções, cela FIA amperométrica integrada a uma unidade de difusão de gases, um sensor amperométrico, além de placas controladoras, mini-potenciostato e um software para controlar o equipamento. Uma elevada reprodutibilidade foi alcançada para análises sequenciais de uma amostra, mas quando a amostra foi trocada a reprodutibilidade foi muito baixa, sendo necessário mais desenvolvimento do sistema FIA automatizado nesta área. / New nanomaterials based on mixed nickel and cobalt hydroxides stabilized in the alpha phase, as well as amperometric sensors based on supramolecular porphyrins and stabilized alpha nickel hydroxide were developed in this thesis. An amperometric FIA sulfite analyzer was also developed in colaboration with of Group of Analytical Instrumentation of IQ-USP, for determination of free SO2 present in liquid samples such as wine, coconut water and fruit juices. The amperometric FIA system is constituted by manual injector, amperometric FIA cell with integrated gas diffusion unit and amperometric sensor based on supramolecular porphyrins, whereas sulfuric acid and electrolyte were used as reactive and carrier solution. Some species such as ascorbic acid, cathecol, glucose and sodium benzoate were evaluated as possible interferents before starting the analyses of real samples. The results were compared with those obtained with the official Monier-Williams method. The concentrations of free SO2 found in fruit juices and coconut water were in accordance with Brazilian law. The amperometric FIA sensors for determination of glucose were based on FTO electrodes modified stabilized alpha nickel hydroxide, which presented excellent linear responses at concentrations below 100 &#181;M. These sensors have shown a very high specific sensitivity for glucose probably associated with their nanostructured nature, and consequent enhanced surface area. Nevertheless, the electrode material was shown to have an increasing tendency to change from alpha to the beta phase as function of the glucose concentration. New materials based on mixed nickel and cobalt hydroxides, stabilized in the alpha phase was prepared and characterized by techniques such as X-ray diffraction, thermogravimetric analysis and Electrochemical Quartz Crystal Microbalance to determine their polymorphic phase. The nanostructured nature of the mixed nickel and cobalt hydroxide materials was confirmed by microscopy techniques such as AFM and SEM. These new materials showed a high specific charge, in fact higher than of nanostructured stabilized alpha nickel hydroxide. An amperometric FIA sulfite analyzer system for liquid samples consisting of solution reservoirs, a sampling system, a solution propulsion system, an amperometric FIA cell with integrated gas diffusion unit, an amperometric sensor based on supramolecular porphyrins, in addition to controller boards, a mini-potentiostat and control software, was developed and tested for determination of free SO2. High reproducibility was achieved for sequential analyses of a sample but the reproducibility after exchange of samples was relatively low, needing further developments in the sampling system.
56

Desenvolvimento de métodos quantitativos e sistema de screening para a determinação de tetraciclinas em medicamentos veterinários e alimentos de origem animal usando procedimentos de análise por injeção em fluxo / Development of quantitative methods and screening system for the determination of tetracyclines in veterinary pharmaceuticals and animal-derived food using flow injection analysis procedures / Desarrollo de métodos cuantitativos y sistema de screening para la determinación de tetraciclinas en medicamentos veterinarios y alimentos de origen animal utilizando procedimientos de análisis por injección en flujo

Pérez Rodríguez, Michael [UNESP] 26 August 2016 (has links)
Submitted by MICHAEL PÉREZ RODRÍGUEZ null (michaelpr@iq.unesp.br) on 2016-09-16T20:43:06Z No. of bitstreams: 1 TESE MICHAEL VERSÃO FINAL.pdf: 4495815 bytes, checksum: 5d4a4f8ffcd143bb08ad336b289fe7ab (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-09-22T14:44:30Z (GMT) No. of bitstreams: 1 perezrodriguez_m_dr_araiq_par.pdf: 1340231 bytes, checksum: 9e639833f42ff1e6fc87e7f9f965f8fc (MD5) / Made available in DSpace on 2016-09-22T14:44:30Z (GMT). No. of bitstreams: 1 perezrodriguez_m_dr_araiq_par.pdf: 1340231 bytes, checksum: 9e639833f42ff1e6fc87e7f9f965f8fc (MD5) Previous issue date: 2016-08-26 / Pró-Reitoria de Pós-Graduação (PROPG UNESP) / Este trabalho descreve o desenvolvimento de métodos analíticos ambientalmente mais amigáveis utilizando sistemas de screening e procedimentos de análise por injeção em fluxo para a detecção e quantificação de antibióticos, da classe das tetraciclinas, em amostras de medicamentos veterinários e alimentos de origem animal como leite bovino e suplementos de ovos. Os métodos desenvolvidos foram baseados na reação de acoplamento diazo obtida entre as tetraciclinas e o ácido p-sulfanílico diazotado em meio básico, resultando na formação de azo compostos com máximos de absorção em torno de 435 nm, permitindo determinar esses antibióticos por espectrofotometria. As condições analíticas foram otimizadas através de análise multivariada utilizando planejamentos experimentais fatoriais e o desempenho dos métodos propostos foi avaliado através de parâmetros como linearidade, efeito matriz, precisão, exatidão, limite de detecção, limite de quantificação, recuperação e estudo de interferências. O primeiro trabalho desenvolvido fez uso de um procedimento de injeção em fluxo contínuo para a rápida determinação de tetraciclinas em formulações veterinárias comerciais, visando maior eficiência no controle de qualidade na indústria farmacêutica. Na sequência, foi desenvolvido um método de screening mediante análise por injeção em fluxo empregando uma cela capilar de longo caminho óptico (LWCC) para a detecção de resíduos de tetraciclinas em amostras de leite bovino, sem a necessidade de passos de extração dispendiosos e demorados ou complicados tratamentos de amostras. Finalmente, um novo método de microextração líquido-líquido dispersiva assistida por ultrassom (US-DLLME) foi desenvolvido para a simples, rápida e eficiente extração de resíduos de tetraciclinas a partir de amostras de suplemento de ovos e, posterior análise por injeção em fluxo baseada em uma cela capilar de longo caminho óptico (LWCC), empregando um banho de aquecimento com controle de temperatura. Os métodos descritos apresentaram importantes características como simplicidade operacional, possibilidade de automação, rapidez e baixo custo das análises. Além disso, estes métodos seguiram os princípios da química verde, de modo que permitiram realizar determinações ambientalmente mais limpas, através da redução considerável do consumo de reagentes e amostras, evitando ou minimizando o emprego de solventes tóxicos. Também, os métodos desenvolvidos para a análise de resíduos mostraram excelente desempenho para aplicação no controle de qualidade dos produtos alimentares estudados na indústria alimentícia, a fim de proteger os consumidores. / This work describes the development of environmentally friendly analytical methods using screening systems and flow injection procedures for detection and quantification of tetracycline antibiotics in veterinary pharmaceuticals and animal-derived foods such as bovine milk and egg-based protein supplements. The developed methods were based on the diazo coupling reaction between the tetracyclines and diazotized p-sulfanilic acid in basic medium, resulting in the formation of azo compounds that present maximum absorption around 435 nm, which allows determining these antibiotics by spectrophotometry. The analytical conditions were optimized by means of multivariate analysis using factorial experimental designs. Performance of the proposed methods was assessed through parameters such as linearity, selectivity, precision, accuracy, detection limit, quantification limit, matrix effect and recovery. The first developed work used a continuous flow injection procedure for the rapid determination of tetracyclines in commercial veterinary formulations, aiming greater efficiency in quality control in the pharmaceutical industry. Thereafter, it was developed a screening method by flow injection analysis using a liquid waveguide capillary cell (LWCC) for detecting tetracyclines residues in bovine milk samples, without the need for expensive extraction steps that are time-consuming or complicated sample treatments. Finally, a new ultrasound-assisted dispersive liquid-liquid microextraction (US-DLLME) method was developed for simple, rapid, and efficient extraction of tetracyclines residues from egg supplement samples, followed by flow injection analysis based on a liquid waveguide capillary cell (LWCC), using a controlled temperature heating bath. The described methods presented important features such as operational simplicity, possibility of automation, quickness and low cost of the analysis. Furthermore, these methods followed the principles of green chemistry, making possible to perform environmentally cleaner determinations, due to the considerable reduction of reagents and samples consumption, avoiding or minimizing the use of toxic solvents. Besides, the methods developed for residues analysis showed excellent performance for application in the food industry for quality control of the studied food products in order to protect consumers.
57

Preparação de hidróxidos mistos nanoestruturados de níquel/cobalto e desenvolvimento de sensores FIA amperométricos / Preparation of nanostructured nickel/cobalt mixed hydroxides and development of FIA amperometric sensors

Paulo Roberto Martins 21 March 2012 (has links)
Nesta tese foram desenvolvidos sensores amperométricos baseados em porfirinas supramoleculares e hidróxido de níquel nanoestruturado e estabilizado na fase alfa, bem como novos materiais baseados em hidróxidos mistos de níquel e cobalto nanoetruturados e estabilizados na fase alfa. Também, um analisador FIA amperométrico, foi desenvolvido em colaboração com o Laboratório de Instrumentação Analítica do IQ-USP, para a determinação e quantificação de SO2 livre em amostras reais, como vinhos, águas de coco e sucos de frutas. Os sensores amperométricos baseados em porfirinas supramoleculares foram empregados na determinação de SO2 livre, presente em sucos de frutas e águas de coco, utilizando um sistema FIA amperométrico. O sistema FIA amperométrico foi constituído de um injetor manual, uma cela amperométrica em fluxo integrada a uma unidade de difusão de gases e um fluxo de uma solução de ácido sulfúrico e de uma solução de eletrólito. Possíveis interferentes como ácido ascórbico, catecol, glicose e benzoato de sódio foram avaliados antes de iniciar as análises das amostras reais. Os resultados das análises foram comparados com o método oficial Monier-Williams. Os níveis de SO2 livre encontrados nas amostras estavam de acordo com o que é preconizado pela Legislação Brasileira. Os eletrodos de FTO, modificados com hidróxido de níquel estabilizado na fase alfa, foram utilizados como sensores amperométricos para a determinação de glicose, usando um sistema FIA amperométrico. Estes sensores apresentaram excelentes respostas lineares em concentrações inferiores a 100 &#181;M. Ainda estes sensores têm apresentado uma sensibilidade específica muito elevada para a glicose, provavelmente associada com a sua natureza nanoestruturada, e consequêntemente sua área superficial aumentada. No entanto o eletrodo modificado apresentou uma tendência de mudar de fase, da fase meta-estável alfa para a fase termodinamicamente estável beta, com o aumento da concentração de glicose. Novos materiais baseados em hidróxidos mistos de níquel e cobalto estabilizados na fase alfa também foram desenvolvidos. A partir de técnicas como difratometria de raio-x e Microbalança Eletroquímica de Cristal de Quartzo (MECQ) foi possível determinar a fase polimórfica dos materiais. Técnicas como AFM e MEV demonstraram que estes materiais são formados por nanopartículas com tamanhos de 5 nm. Estes nanomateriais apresentaram uma maior quantidade de carga específica, em comparação com o hidróxido de níquel puro. E por último um analisador FIA amperométrico automatizado foi desenvolvido para a realização de análises de SO2 livre em amostras líquidas. Este analisador é composto por reservatórios de soluções, sistema de amostragem, sistema de propulsão das soluções, cela FIA amperométrica integrada a uma unidade de difusão de gases, um sensor amperométrico, além de placas controladoras, mini-potenciostato e um software para controlar o equipamento. Uma elevada reprodutibilidade foi alcançada para análises sequenciais de uma amostra, mas quando a amostra foi trocada a reprodutibilidade foi muito baixa, sendo necessário mais desenvolvimento do sistema FIA automatizado nesta área. / New nanomaterials based on mixed nickel and cobalt hydroxides stabilized in the alpha phase, as well as amperometric sensors based on supramolecular porphyrins and stabilized alpha nickel hydroxide were developed in this thesis. An amperometric FIA sulfite analyzer was also developed in colaboration with of Group of Analytical Instrumentation of IQ-USP, for determination of free SO2 present in liquid samples such as wine, coconut water and fruit juices. The amperometric FIA system is constituted by manual injector, amperometric FIA cell with integrated gas diffusion unit and amperometric sensor based on supramolecular porphyrins, whereas sulfuric acid and electrolyte were used as reactive and carrier solution. Some species such as ascorbic acid, cathecol, glucose and sodium benzoate were evaluated as possible interferents before starting the analyses of real samples. The results were compared with those obtained with the official Monier-Williams method. The concentrations of free SO2 found in fruit juices and coconut water were in accordance with Brazilian law. The amperometric FIA sensors for determination of glucose were based on FTO electrodes modified stabilized alpha nickel hydroxide, which presented excellent linear responses at concentrations below 100 &#181;M. These sensors have shown a very high specific sensitivity for glucose probably associated with their nanostructured nature, and consequent enhanced surface area. Nevertheless, the electrode material was shown to have an increasing tendency to change from alpha to the beta phase as function of the glucose concentration. New materials based on mixed nickel and cobalt hydroxides, stabilized in the alpha phase was prepared and characterized by techniques such as X-ray diffraction, thermogravimetric analysis and Electrochemical Quartz Crystal Microbalance to determine their polymorphic phase. The nanostructured nature of the mixed nickel and cobalt hydroxide materials was confirmed by microscopy techniques such as AFM and SEM. These new materials showed a high specific charge, in fact higher than of nanostructured stabilized alpha nickel hydroxide. An amperometric FIA sulfite analyzer system for liquid samples consisting of solution reservoirs, a sampling system, a solution propulsion system, an amperometric FIA cell with integrated gas diffusion unit, an amperometric sensor based on supramolecular porphyrins, in addition to controller boards, a mini-potentiostat and control software, was developed and tested for determination of free SO2. High reproducibility was achieved for sequential analyses of a sample but the reproducibility after exchange of samples was relatively low, needing further developments in the sampling system.

Page generated in 0.0739 seconds