Spelling suggestions: "subject:"arritmias""
51 |
Contribuição das eletrocardiografias convencional, holter e de alta resolução no diagnóstico da cardiomiopatia arritmogênica do ventrículo direito dos cães da raça boxer /Pereira, Evandro Zacché. January 2011 (has links)
Orientador: Aparecido Antonio Camacho / Banca: Wagner Luís Ferreira / Banca: Mirela Tinucci Costa / Resumo: Com o objetivo de investigar a importância de ferramentas que possam identificar as arritmias ou detectar seus possíveis fatores desencadeantes em portadores da cardiomiopatia arritmogênica do ventrículo direito, 25 cães Boxers foram submetidos ao exame eletrocardiográfico convencional (ECG) e variabilidade da frequência cardíaca (VFC), obtida pela avaliação Holter de 24 horas, e 20 foram submetidos ao exame eletrocardiográfico de alta resolução (ECGAR). Os cães foram divididos em três grupos de acordo com o número de extrassístoles ventriculares (EV) obtidas pela avaliação Holter. O GC foi composto por cães apresentando menos de 20 EV/24 horas, o GD1 foi formado por animais com mais de 100 e menos de 1.000 EV/24 horas, enquanto o GD2 foi composto por animais que apresentaram mais de 1.000 EV/24 horas. Levando em consideração a presença de EV e extrassístoles supraventriculares (ESV) no ECG, este teste apresentou 83,33% de sensibilidade, 100% de especificidade, valor preditivo positivo (VPP) de 100% e valor preditivo negativo (VPN) de 86%. Os parâmetros da VFC SDNNIDX (Gc: 194,08 ± 56,29 ms; GD1: 202,20 ± 94,79 ms; GD2: 118,00 ± 43,76 ms) e pNN>50 (Gc: 39,75 ± 12,69 ms; GD1: 46,24 ± 14,08; GD2: 21,52 ± 9,27 ms) foram significativamente menores nos pacientes do GD2. O ECGAR apresentou sensibilidade de 30%, especificidade de 50%, VPP de 37,5% e VPN de 41,67%. Assim, os resultados sugerem que a eletrocardiografia convencional e a VFC são técnicas que podem contribuir substancialmente no diagnóstico da CAVD em cães Boxers, ao contrário da eletrocardiografia de alta resolução que se mostrou ineficaz em identificar a presença de potenciais tardios nos pacientes com esse grau de doença / Abstract: Aiming to investigate the importance of tools that could identify arrhythmias or detect its possible inciting factor in patients affected by arrhythmogenic right ventricular cardiomyopathy, 25 Boxer dogs were submitted to conventional electrocardiogram (ECG), heart rate variability (HRV), obtained by 24-hours Holter evaluation, and 20 were submitted to high resolution electrocardiogram (HRECG). Dogs were divided into three different groups according to the number of ventricular complexes (VC) obtained in Holter analysis. The GC was formed by dogs presenting less than 20 VC/24 hours, the GD1 was formed by animals presenting more than 100 and less than 1.000 VC/24 hours, while the GD2 was composed of dogs presenting over a 1.000 VC/24 hours. Considering the presence of ventricular or supraventricular complexes on the ECG, this test had 83,33% of sensitivity, 100% of specificity, positive predictive value (PPV) of 100% and negative predictive value (NPV) of 86%. The HRV parameters SDNNIDX (Gc: 194.08 ± 56.29 ms; GD1: 202.20 ± 94.79 ms; GD2: 118.00 ± 43.76 ms) and pNN>50 (Gc: 39.75 ± 12.69 ms; GD1: 46.24 ± 14.08; GD2: 21.52 ± 9.27 ms) were significantly lower in the patients of GD2. The HRECG showed 30% of sensitivity, 50% of specificity, PPV of 37,5% and NPV of 41,67%. Thus, the results suggest that conventional ECG and HRV are techniques that can strongly contribute in the diagnosis of ARVD in Boxer dogs, opposed to HRECG that showed itself inefficient to detect the presence of late potentials in patients with this degree of disease / Mestre
|
52 |
Arritmogenese por catecolaminas em miocardio atrial e ventricular de ratos : metodologia e tipos de adrenoceptores envolvidos / Arrythmogenesis by catecholamines in atrial and ventricular rat myocardium : methodology and types of adrenoceptorsBoer, Denile Cominato, 1980- 30 January 2006 (has links)
Orientadores: Jose Wilson Magalhães Bassani, Rosana Almada Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-06T07:47:18Z (GMT). No. of bitstreams: 1
Boer_DenileCominato_M.pdf: 557480 bytes, checksum: e378c01e865d04a595d3f0e7ad3c60dd (MD5)
Previous issue date: 2006 / Resumo: Embora haja demonstração de que a estimulação simpática tenha efeito facilitatório sobre a indução de atividade espontânea em miocárdio há controvérsia sobre a participação dos tipos de adrenoceptores na mediação deste efeito. No presente trabalho, descrevemos um método desenvolvido para determinação, em átrio esquerdo isolado (AE) de rato, da relação concentração-efeito para agentes que exercem efeito arritmogênico por aumento da mobilização celular de 'Ca POT. 2+¿. O método baseou-se na interposição de pausas estimulatórias, durante as quais registraram-se contrações espontâneas (CE), precedidas ou não por trens estimulatórios de alta freqüência (5 Hz). O protocolo estimulatório foi repetido na presença de diferentes concentrações de agonistas. Para cada concentração de agonista, a resposta arrítmica foi considerada como a soma dos números de CE/min, no total de preparações. Foi analisada também a resposta inotrópica, como sendo o incremento de força ou encurtamento de pico, desenvolvidos em AE e miócitos ventriculares (MV), respectivamente. A relação foi ajustada por uma função sigmóide para cálculo de Min (i.e., valor da variável na ausência do agonista), Rmax (resposta máxima) e pD2 (-log da concentração do agonista que produziu uma resposta igual a 50% de Rmax). Este método foi aplicado no estudo dos tipos de adrenoceptores envolvidos na resposta arrítmica a catecolaminas em AE e MV. A Rmax inotrópica à ativação de adrenoceptores 'alfa IND. 1¿ + 'beta IND. 1¿ foi comparável àquela por ativação de apenas receptores 'beta IND. 1¿, em ambos AE e MV. Já a ativação de adrenoceptores 'alfa IND. 1¿ produziu uma Rmax inotrópica de apenas metade daquela observada pela estimulação 'alfa IND. 1¿ + 'beta IND. 1¿. Da mesma forma, a resposta arrítmica foi semelhante para estimulação de adrenoceptores a1+ß1 e de apenas receptores 'beta IND. 1¿. Entretanto, nenhuma resposta foi obtida pela estimulação de receptores adrenérgico do tipo 'alfa IND. 1¿. Estes resultados indicam que a estimulação de adrenoceptores 'alfa IND. 1¿, apesar de evocar uma resposta inotrópica positiva em ambos AE e MV, não é arritmogênica. A ativação do tipo 'beta¿, por outro lado, parece ser a principal via para estimulação inotrópica simpática e na indução de arritmias. Além disso, concluímos que parece existir antagonismo funcional entre os subtipos de adrenoceptores 'beta¿, manifestado por ações pró- e anti-arrítmicas dos subtipos 'beta IND. 1¿ e 'beta IND. 2¿, respectivamente, em miocárdio (tanto atrial, quanto ventricular) de rato / Abstract: Although it has been shown that sympathetic stimulation facilitates the appearance of myocardial spontaneous activity, it is still not clear which types of adrenoceptors mediate this effect. In this study, we describe a method developed for determination, in isolated rat atria (AE), of the concentration-effect relationship for arrhythmogenic agents that act via promotion of cell 'Ca POT. 2+¿ overload. The method was based on the interposition of stimulatory rest periods, during which spontaneous contractions (CE) were recorded, preceded or not by high frequency (5 Hz) stimulus trains. The stimulation protocol was applied at each agonist concentration, and the arrhythmic response was taken as the sum of the number of CE/min in all preparations. The positive inotropic response was considered as the agonist-dependent increment of developed force or peak shortening in AE and isolated ventricular myocytes (MV), respectively. Concentration-effect curves were determined by fitting a sigmoid function, from which the following parameters were estimated: Min (i.e., value of the variable in the absence of the agonist), Rmax (maximal response) e 'pD IND. 2¿ (-log of the molar agonist concentration that evokes a response equal to 50% of Rmax). This method was applied to investigate the adrenoceptor types involved in the mediation of catecholamine-induced arrhythmogenesis in AE and MV. Inotropic Rmax to activation of 'alfa IND. 1¿ + 'beta IND. 1¿ adrenoceptors was comparable to that of activation of solely 'beta IND. 1¿ adrenoceptors in both AE and MV. However, Rmax to selective 'alfa IND. 1¿ adrenoceptor activation was only half of that produced by 'alfa IND. 1¿ + 'beta IND. 1¿ adrenoceptor stimulation. The arrhythmic responses to 'alfa IND. 1¿ + 'beta IND. 1¿ and 'beta IND.1¿ receptor stimulation were similar, but selective a1 adrenoceptor activation was unable to evoke any spontaneous activity. The results indicate that a1 adrenoceptors, although able to mediate stimulation in both AE and MV, are not involved in arrhythmogenesis. 'beta¿-adrenoceptor activation, thus, seems the main type involved in both inotropic and arrhythmic responses to catecholamines. In addition, our results point out a functional antagonism between 'beta¿-adrenoceptor subtypes: i.e., pro- and anti-arrhythmic effects mediated by 'beta IND. 1¿ and 'beta IND. 2¿-adrenoceptors, respectively in both atrial and ventricular rat myocardium / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
|
53 |
Frequência de arritmias ventriculares após injeção intracoronária de células-tronco da medula óssea em pacientes com cardiomiopatia chagásica / Frequency of ventricular arrhythmia after injection of stem cells from the bone marrowMarques, Adriana Sebba Barroso de Souza 20 December 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:36:47Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Dissertação-Adriana Sebba Barroso de Souza Marques.pdf: 867953 bytes, checksum: 6484d53b38c78accaea85498548eb55f (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:23:56Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Dissertação-Adriana Sebba Barroso de Souza Marques.pdf: 867953 bytes, checksum: 6484d53b38c78accaea85498548eb55f (MD5) / Made available in DSpace on 2014-12-16T09:23:56Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Dissertação-Adriana Sebba Barroso de Souza Marques.pdf: 867953 bytes, checksum: 6484d53b38c78accaea85498548eb55f (MD5)
Previous issue date: 2013-12-20 / Background: Treatment with stem cells in various cardiomyopathies may be related to the increase in arrhythmias. Objective: To determine whether intracoronary injection of stem cells in patients with Chagas cardiomyopathy is associated with increased frequency of ventricular arrhythmias, compared to the control group. Methods: A retrospective cohort study that evaluatedt he medical records of 60 patients Who participated previously on sectional study.The following data was collected : age, sex , and drugs used and Holter variables that demonstrated the presence of arrhythmias.Holter was performed in four stages: randomization , 2 , 6 and 12 months segments. The control group (CG) received medical treatment and intracoronary injection of placebo and the study group (SG) drug treatment and autologous stem cell implant. Results: There was no difference between EG and CG analyzing the criteria of arrhythmia. In the intra-group analysis, significant difference was found between the Holter tests study group in the variable of total ventricular ectopic compared with baseline, being between H1 and H2 p=0.014, between H1 and H3 p=0.004, between H1and H4 p=0.014. The variable non-sustained ventricular tachycardia between H1 and H3 with p = 0.036. Conclusion: The intracoronary injection of stem cells did not increase the incidence of ventricular arrhythmias in patients with Chagas cardiomopatia compared to the control group. / Fundamento: O tratamento com células-tronco nas diversas cardiomiopatias pode estar relacionado ao aumento nas arritmias. Objetivo: Determinar se a injeção intracoronária de células-tronco em portadores de cardiomiopatia chagásica está associada ao aumento da frequência de arritmias ventriculares, comparado ao grupo controle. Método: Estudo de coorte retrospectivo que avaliou o prontuário de 60 pacientes que participaram de estudo transversal anterior. Foram coletados os seguintes dados: idade, sexo, medicamentos utilizados e variáveis do Holter que demonstraram presença de arritmia. O Holter foi realizado em quatro momentos: randomização, 2, 6 e 12 meses de seguimento. O grupo controle (GC) recebeu tratamento medicamentoso e injeção intracoronária de placebo e o grupo estudo (GE) tratamento medicamentoso e implante autólogo de células tronco. Resultados: Não houve diferença entre o GE e o GC nos critérios de arritmia analisados. Na analise intra-grupo foi encontrado diferença com significância entre os exames de HOLTER do grupo estudo na variável total de extrassístoles ventriculares comparado com o basal, sendo entre H1 e H2 p=0.014, entre H1 e o H3 p=0.004, entre H1 e H4 p=0.014. A variável taquicardia ventricular não sustentada entre H1 e H3 com p=0.036. Conclusão: A injeção intracoronária de células-tronco não aumentou a incidência de arritmias ventriculares em pacientes com cardiomopatia chagásica comparada ao grupo controle.
|
54 |
Simulações computacionais de arritmias cardíacas em ambientes de computação de alto desempenho do tipo Multi-GPUBarros, Bruno Gouvêa de 25 February 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-02-24T12:24:27Z
No. of bitstreams: 1
brunogouveadebarros.pdf: 4637517 bytes, checksum: 0db5f859f17bd37484772dd26a331ce5 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-02-24T15:33:28Z (GMT) No. of bitstreams: 1
brunogouveadebarros.pdf: 4637517 bytes, checksum: 0db5f859f17bd37484772dd26a331ce5 (MD5) / Made available in DSpace on 2017-02-24T15:33:28Z (GMT). No. of bitstreams: 1
brunogouveadebarros.pdf: 4637517 bytes, checksum: 0db5f859f17bd37484772dd26a331ce5 (MD5)
Previous issue date: 2013-02-25 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Os modelos computacionais tornaram-se ferramentas valiosas para o estudo e compreensão
dos fenômenos da eletrofisiologia cardíaca. No entanto, a elevada complexidade dos
processos biofísicos e o nível microscópico de detalhes exigem complexos modelos
computacionais. Aspectos-chave da eletrofisiologia cardíaca, tais como condução lenta
e bloqueio de condução tem sido tema de pesquisa de muitos estudos, uma vez que estão
fortemente relacionados à arritmia cardíaca. No entanto, ao reproduzir estes fenômenos
os modelos necessitam de uma discretização sub-celular para a solução das equações
diferenciais e uma condutividade eléctrica do tecido não uniforme e heterogênea. Devido
aos elevados custos computacionais de simulações que reproduzem a microestrutura
fina do tecido cardíaco, estudos prévios têm considerado experimentos de tecido de
pequenas dimensões e têm utilizados modelos simples de células cardíacas. Neste trabalho,
desenvolvemos um modelo (modelo microscópico) da eletrofisiologia cardíaca que capta a
microestrutura do tecido cardíaco usando uma discretização espacial muito fina (8µm) e
utilizamos um modelo celular moderno e complexo baseado em Cadeias de Markov para
a caracterização da estrutura e dinâmica dos canais iônicos. Para lidar com os desafios
computacionais, o modelo foi paralelizado usando uma abordagem híbrida: a computação
em cluster e GPGPUs (General-purpose computing on Graphics Processing Units). Nossa
implementação paralela deste modelo, utilizando uma plataforma multi-GPU, foi capaz de
reduzir os tempos de execução das simulações de mais de 6 dias (em um único processador)
para 21 minutos (em um pequeno cluster de 8 nós equipado com 16 GPUs). Além disso,
para diminuir ainda mais o custo computacional, foi desenvolvido um modelo discreto
equivalente ao modelo microscópico. Este novo modelo foi paralelizado usando a mesma
abordagem do modelo microscópico e foi capaz de executar simulações que demoravam
21 minutos em apenas 65 segundos. Acreditamos que esta nova implementação paralela
abre caminho para a investigação de muitas questões em aberto associadas à natureza
complexa e discreta da propagação dos potenciais de ação no tecido cardíaco. / Computer models have become valuable tools for the study and comprehension of the
complex phenomena of cardiac electrophysiology. However, the high complexity of the
biophysical processes and the microscopic level of details demand complex mathematical
and computational models. Key aspects of cardiac electrophysiology, such as slow
conduction, conduction block and saltatory effects have been the research topic of many
studies since they are strongly related to cardiac arrhythmia. However, to reproduce these
phenomena the numerical models need to use sub-cellular discretization for the solution
of the PDEs and nonuniform, heterogeneous tissue electric conductivity. Due to the
high computational costs of simulations that reproduce the fine microstructure of cardiac
tissue, previous studies have considered tissue experiments of small or moderate sizes
and used simple cardiac cell models. In this work we develop a cardiac electrophysiology
model (microscopic model) that captures the microstructure of cardiac tissue by using
a very fine spatial discretization (8µm) and uses a very modern and complex cell model
based on Markov Chains for the characterization of ion channel's structure and dynamics.
To cope with the computational challenges, the model was parallelized using a hybrid
approach: cluster computing and GPGPUs (General-purpose computing on graphics
processing units). Our parallel implementation of this model using a Multi-GPU platform
was able to reduce the execution times of the simulations from more than 6 days (on a
single processor) to 21 minutes (on a small 8-node cluster equipped with 16 GPUs).
Furthermore, in order to decrease further the computational cost we have developed a
discrete model equivalent to the microscopic one. This new model was also parallelized
using the same approach as the microscopic model and was able to perform simulations
that took 21 minutes to be executed in just 65 seconds. We believe that this new parallel
implementation paves the way for the investigation of many open questions associated
|
55 |
Acurácia do gravador de eventos do marcapasso cardíaco artificial versus Holter na detecção de arritmias ventriculares sintomáticas e assintomáticas / Accuracy of the artificial pacemakers monitoring system versus 72h Holter in the detection of symptomatic and asymptomatic ventricular arrhythmiasStela Maria Vitorino Sampaio 30 September 2015 (has links)
O sistema Holter é considerado padrão ouro para detecção de arritmias cardíacas, possibilitando o seu diagnóstico e sua relação com os sintomas do paciente. As novas gerações de marcapassos (MP) detectam e registram eletrogramas intracavitários e poderiam dispensar o Holter no seguimento dos pacientes. Os diferentes MP dispõem de algoritmos de detecção de arritmias ventriculares (AV) que variam de acordo com o modelo e sua correlação diagnóstica com Holter foi pouco estudada. O objetivo desse estudo foi avaliar 1. a correlação entre o monitor de eventos dos MP e do Holter na detecção de AV e 2. a concordância das AV detectadas nos dois sistemas. Foram estudados129 pacientes portadores de MP com função de detecção de arritmias, com idade média de 68,6+19.1 anos (entre 19 e 94), 54,8% do sexo feminino. Os pacientes foram submetidos à monitorização com Holter por 72 horas. Assim que o sistema foi ligado, os contadores de eventos dos marcapassos foram reiniciados e os relógios sincronizados, para que ambos os sistemas detectassem os eventos simultaneamente. Os MP foram programados para detecção de eventos com o menor valor de frequência ventricular (FV) e o menor número de batimentos sequenciais (BT) possíveis. Depois de 72 horas, os sistemas Holter foram retirados e os registros analisados, assim como os registros simultâneos dos gravadores dos MP. Foram qualificados como eventos arrítmicos no Holter e MP, respectivamente: EV isoladas e \"PVC\"; extra-sístoles em pares e \"couplets\"; TVNS (> 3BT) e \"triplets\"(3BT), \"runs\"(3 a 8 ou > 8 BT) e \"HVR\" (3 ou 4 BT). As correlações de Spearman foram utilizadas para avaliar se o marcapasso acompanha a detecção dos parâmetros do Holter. Os coeficientes de correlação intraclasse e os respectivos intervalos com 95% de confiança, calculados para avaliar a concordâncias entre os parâmetros equivalentes do marcapasso e do Holter. Foram calculados os coeficientes Kappa para avaliar a concordância na detecção de > 10 \"PVC\"/h com > 10 EV/h. Resultados: Os monitores dos marcapassos subestimaram o Holter. Os registros de \"PVC\", \"triplet\" e \"HVR\" por TVNS apresentaram correlações positivas em relação aos parâmetros do Holter, sendo a mais alta aquela entre \"PVC\" e EV (r=0,501). Porém, a concordância entre os tipos de arritmias detectadas foi baixa (CCI < 0,5), exceção feita à concordância de \"triplet\" com TVNS de três batimentos (CCI=0.984). A concordância na detecção de mais de 10 PVC/h e mais de 10 EV/h foi moderada (kappa= 0,483), embora para os MP da Medtronic, o coeficiente de concordância foi alto (kappa=0.877). Para os MP com algoritmo de detecção de sequências de três batimentos com FV menor que 140bpm ( < 140/3), a correlação entre HVR e TVNS foi expressiva (r = 1), sendo a concordância entre esses parâmetros também bastante alta (CCI = 0,800). Conclusões: A correlação e a concordância na detecção de AV registradas nos MP e no Holter foram inconsistentes. Padronização dos algoritmos de detecção de AV, semelhantes os do sistema Holter, é necessária para que os pacientes portadores de dispositivos implantáveis possam se beneficiar dessa função para seguimento clínico e estratificação de risco / The Holter monitoring is considered the gold standard method for detection of cardiac arrhythmias, enabling its diagnosis and its correlation with the patient\'s symptoms. New generations of artificial pacemakers can detect and record intracavitary electrograms and, theoretically, could discard the Holter during the follow-up of the patients. Pacemakers have different ventricular arrhythmias (VA) detection algorithms, varying according to the model. Their diagnosis capacity comparing to Holter monitoring has been poorly studied. The aim of this study was to evaluate 1. the correlation between the event monitor of the pacemaker and the Holter in VA detection and 2. the agreement between the VA detected in both systems. We studied 129 patients with implanted pacemakers, which had arrhythmia detection function, mean age of 68.6 + 19.1 years (19 to 94), 54.8% female. The patients underwent Holter monitoring for 72 hours. Once the system was connected, event counters of pacemakers were reset and the clocks synchronized, so that both systems could detect the arrhythmic events simultaneously. The pacemakers were programmed to detect events with the lowest ventricular rate and lowest number of sequential beats allowed for each model. After 72 hours, Holter systems were removed and the records analyzed, as well as the simultaneous records of the pacemakers. Were considered as arrhythmic events: PVC isolated (in the pacemaker described as \"PVC\"); premature beats in pairs (pacemaker described as \"couplets\"); NSVT (pacemaker described as \"triplets\"- 3beats, \"runs\"- 4 to 8 or > 8 beats and \"HVR\"- 3 to 4 beats). Spearman rank correlations were used to assess whether the pacemaker and Holter identified the same parameters. The intraclass correlation coefficients and the respective intervals with 95% confidence were calculated to evaluate the concordance between the equivalent parameters of the pacemaker and Holter. Kappa coefficients were calculated to assess the agreement in the detection of > 10 PVC/h by the pacemakers and by the Holter. Results: The pacemakers underestimated the arrhythmias detection of Holter. Records of \"PVC\", \"triplet\" and \"HVR\" by NSVT showed positive correlations with the Holter parameters, and the highest one was among \"PVC\" and EV (r = 0.501). The agreement between the types of arrhythmias detected was quite low (CCI < 0.5), except for \"triplet\" detected by pacemakers and three beats NSVT by Holter (ICC = 0.984). The correlation detection for more than 10 PVC /h was moderate (kappa = 0.483), except for Medtronic pacemakers (kappa=0.877). When the pacemaker was programmed to detect sequences of three beats with heart rate lower than 140bpm ( < 140/3), the correlation between HVR and NSVT was perfect (r = 1) and the agreement between these parameters was also quite high (ICC = 0.800). Conclusions: The correlation and agreement between pacemakers and Holter monitoring in the detection of VA were not consistent. A standardization of the pacemakers\' detection algorithms is necessary before using this function for clinical follow-up and risk stratification of the patients
|
56 |
Estudo comparativo do uso de anestésicos locais com ou sem vasoconstritor em pacientes com arritmias cardíacas durante tratamento odontológico de rotina / Comparative study using local anesthesic solution with and without vasoconstrictor in patients wiht cardiac arrhytmias during routine dental treatmentMaria Teresa Fernández Cáceres 23 February 2007 (has links)
A utilização de anestésicos locais associados a substâncias vasoconstritoras para tratamento odontológico de rotina de pacientes cardiopatas ainda é controversa, devido ao risco de efeitos cardiovasculares adversos. Objetivo: avaliar possíveis alterações hemodinâmicas relacionadas ao uso de anestésico local com vasoconstritor não adrenérgico em pacientes portadores de arritmias cardíacas comparando ao uso de anestésico sem vasoconstritor. Métodos: Estudo prospectivo randomizado, avaliou 33 pacientes com sorologia positiva para Doença de Chagas e 32 pacientes com Doença Arterial Coronariana, portadores de arritmia ventricular complexa ao Holter (>10 EV/h e TVNS), 21 do sexo feminino; idade 54,73 ± 7,94 anos, submetidos a tratamento odontológico de rotina com anestesia pterigomandibular, divididos em dois grupos: Grupo I -utilizando-se prilocaína a 3% com felipressina 0,03 UI/ml e Grupo II -lidocaína 2% sem vasoconstritor. Foram avaliados o número e complexidade de extrassístoles, a freqüência cardíaca e a pressão arterial sistêmica dos pacientes no dia anterior, uma hora antes, durante e uma hora após o procedimento odontológico. Resultados: Não foram observadas alterações hemodinâmicas relacionadas ao anestésico utilizado, nem diferença estatisticamente significativa entre os grupos. Conclusão: Prilocaína a 3% com felipressina 0,03 UI/ml pode ser utilizada com segurança em pacientes chagásicos e coronarianos com arritmia ventricular complexa. / The use of a local anesthetic solution with a vasoconstrictor agent for routine dental treatment in patients with cardiovascular disease is still controversial. Objetive: to evaluate the possible hemodynamics effects related to the use of a local anesthetic solution associated with a non-adrenergic vasoconstrictor agent, comparatively to another local anesthetic solution without a vasoconstrictor agent, in patients with cardiac arrhythmia. Methods: Prospective, randomized study, evaluated 33 patients with Chagas´s Cardiomyopathy and 32 with Coronary Artery Disease, 21 female; mean age 54,73 ± 7,94 of years old and complex ventricular arrhythmia detected by the 24 hours Holter monitoring. The patients underwent a routine dental treatment with pterygomandibular anesthesia, divided into two groups: Group I - received local anesthesia with 3% prilocaine associated with felypressin 0,03UI/ml and Group II - received 2% lidocaine without vasoconstrictor. Heart rate, number and complexity of premature ventricular beats and systemic blood pressure were monitored the day before, one hour before, during and one hour after dental treatment. Results: There were no changes in the homodynamic parameters related to the anesthetic solution and no significant differences were observed between the two groups. Conclusion: These findings suggest that 3% prilocaine with felypressin 0,03 UI/ml can be safely used in patients with complex ventricular arrhythmia associated with Chagas´s and coronary artery desease.
|
57 |
Relação entre apnéia do sono, isquemia miocárdica, variabilidade da freqüência cardíaca e arritmias em portadores de doença arterial coronária / Relation between sleep apnea, myocardial ischemia, heart rate variability and arrhythmias in patients with coronary artery diseaseCristiana Marques de Araújo 02 May 2007 (has links)
Introdução: É comum a associação entre apnéia do sono e a doença arterial coronária (DAC), devido a fatores predisponentes comuns como sexo masculino e obesidade. Entretanto, ainda não existe uma definição objetiva da relação entre apnéia e DAC. Objetivo: Avaliar se os episódios de isquemia miocárdica, a variabilidade da freqüência cardíaca (VFC) e as arritmias cardíacas de portadores de DAC sofrem alteração na presença da apnéia do sono. Métodos: Cinqüenta e três pacientes portadores de DAC foram submetidos à monitorização eletrocardiográfica ambulatorial de 48 horas e ao estudo do sono na primeira noite da monitorização. Os pacientes foram divididos de acordo com o índice de apnéia e hipopnéia (IAH) em: grupo Controle (IAH<=15) e grupo Apnéia (IAH>15). Os grupos foram comparados quanto à isquemia miocárdica, VFC e arritmias cardíacas ocorridas no período da vigília e do sono. Uma subanálise apenas com pacientes portadores de apnéia grave (IAH>30 - grupo Ap-Grave) foi realizada e comparada ao grupo Controle. A análise estatística foi realizada utilizando-se o teste de Mann-Whitney, teste de Fisher e teste T de student. Resultados: Não foram observadas diferenças nas características clínicas básicas entre os grupos, exceto pelos níveis de pressão arterial mais elevada no grupo Ap-Grave (p<0,05). Nenhum dos pacientes despertou por angina noturna; 75% foram submetidos a cateterismo cardíaco, sem diferença quanto à gravidade da DAC e aos valores da fração de ejeção. Foi registrada isquemia em 39 (73,58%) pacientes, com carga isquêmica de 2892,26 minutos na vigília e 1186 no sono. Na vigília, foi menor a duração dos episódios isquêmicos no grupo Ap- Grave (p<0,05); no período do sono não houve diferença entre os grupos. Não houve diferença nas medidas da VFC e arritmias entre os grupos. Não foram registradas pausas >2 segundos, fibrilação ou flutter atrial, ou qualquer tipo de bloqueio atrioventricular. Conclusão: A apnéia do sono não apresentou relação direta com isquemia miocárdica, variabilidade da freqüência cardíaca e arritmias cardíacas em pacientes portadores de DAC. / Introduction: It is common to associate obstructive sleep apnea (OSA) with coronary artery disease (CAD) given the common predisposing factors; however, there are still controversies on the influence of OSA in the progression of CAD. Objective: To assess if OSA causes any changes in myocardial ischemia episodes, heart rate variability (HRV) and cardiac arrhythmias in patients with CAD. Methods: Fifty-three people with CAD were submitted to ambulatory electrocardiographic monitoring and to polysomnography) simultaneously and divided according to the apnea-hypopnea index (AHI) into two groups: Control (AHI<=15) and Apnea (AHI>15). A sub analysis including only people with severe apnea (AHI>30) was done and compared with the control group. Results: Differences in the basic clinical characteristics between the groups were not found, except for higher blood pressure levels in the Severe Apnea Group (p<0.05). None of the patients woke up because of nocturnal angina. The groups did not differ in relation to the extension of coronary artery disease and ejection fraction values. Myocardial ischemia was recorded in 39 (73.58%) patients. The total ischemic burden was 2892.26 minutes while awake and 1186 minutes while asleep; the groups did not differ during sleep. There was also no significant difference in HRV and arrhythmia measurements between the groups. Pauses >2 seconds, fibrillation or atrial flutter or any type of atrioventricular blocks were not registered. Conclusion: OSA did not present a direct relationship with myocardial ischemia, heart rate variability and arrhythmias in patients with CAD.
|
58 |
The use of human induced pluripotent stem cell-derived atrial cardiomyocytes for studying arrhythmia mechanismsCasini, Marilù 13 May 2024 (has links)
[ES] Cada año, cientos de miles de nuevos casos en todo el mundo son diagnosticados anualmente con fibrilación auricular, estimándose que aproximadamente 33.5 millones de personas viven con esta compleja enfermedad. Sin embargo, se hizo evidente que la fibrilación auricular es una enfermedad multifacética y progresiva. Por lo tanto, se requiere el desarrollo de nuevos modelos experimentales que recapitulen este complejo mecanismo.
Por esta razón, esta tesis ha navegado a través del intrincado panorama del remodelado de la fibrilación auricular desde un punto de vista electrofisiológico, estructural e inmunológico, utilizando un modelo in vitro de cardiomiocitos atriales derivados de células madre pluripotentes inducidas humanas (hiPSC-aCM). El modelo demostró ser capaz de recapitular mecanismos de reentrada, así como remodelados genéticos correlacionados con cambios electrofisiológicos, estructurales e inmunológicos similares a los observados en pacientes con fibrilación auricular, demostrando su valor como modelo para estudiar los mecanismos de iniciación de la arritmia. Además, la tesis exploró enfoques optogenéticos innovadores para la perturbación del potencial de acción en hiPSC-aCM, demostrando su posible uso para la terminación de la arritmia.
En conclusión, esta tesis de doctorado realiza una contribución significativa al desarrollo y prueba de un nuevo modelo in vitro de fibrilación auricular en atrios humanos, proporcionando una base sólida para futuras mejoras en los objetivos terapéuticos y medicamentos. / [CA] Cada any, centenars de milers de nous casos a tot el món són diagnosticats anualment amb fibrilació auricular, estimantse que aproximadament 33.5 milions de persones viuen amb aquesta complexa malaltia. No obstant això, es va fer evident que la fibril·lació auricular és una malaltia multifacètica i progressiva. Per tant, es requereix el desenvolupament de nous models experimentals que recapitulen aquest complex mecanisme.
Per aquesta raó, aquesta tesi ha navegat a través del intrincat panorama del remodelat de la fibrilació auricular des d'un punt de vista electrofisiològic, estructural i immunològic, utilitzant un model in vitro de cardiomiòcits atrials derivats de cèlules mare pluripotents induïdes humanes (hiPSC-aCM). El model va demostrar ser capaç de recapitular mecanismes de reentrada, així com remodelats genètics correlacionats amb canvis electrofisiològics, estructurals i immunològics similars als observats en pacients amb fibril·lació auricular, demostrant el seu valor com a model per estudiar els mecanismes d'iniciació de l'arítmia. A més, la tesi va explorar enfocs optogenètics innovadors per a la pertorbació del potencial d'acció en hiPSC-aCM, demostrant el seu possible ús per a la terminació de l'arítmia.
En conclusió, aquesta tesi de doctorat realitza una contribució significativa al desenvolupament i prova d'un nou model in vitro de fibril·lació auricular en atris humans, proporcionant una base sòlida per a futures millores en els objectius terapèutics i medicaments. / [EN] Each year hundreds of thousands of new cases worldwide are annually diagnosed with atrial fibrillation (AF), estimating that approximately 33.5 million of people worldwide live with this complex disease. However, it became clear that AF is not only a prevalent cardiac arrhythmia but also a multifaceted and progressive one. Thus, the development of new experimental models that recapitulate this complex mechanism is required.
For this reason, this thesis has navigated through the intricate landscape of AF remodeling under an electrophysiological, structural and immunological point of view using an in vitro model of human induced pluripotent stem cell-derived atrial cardiomyocytes (hiPSC-aCM). The model showed to be able to recapitulate re-entry mechanisms as well as genetic remodeling correlated to electrophysiological, structural and immunological changes similar to those observed in AF patients, demonstrating its value as model for studying initiation arrhythmia mechanisms. Furthermore, the thesis explored innovative optogenetic approaches for action potential perturbation in hiPSC-aCM, demonstrating their possible use for arrhythmia termination.
In conclusion, this PhD thesis makes a significant contribution to the development and testing of a new human atrial in vitro model of AF, providing a strong basis for future improvements of therapeutic target and drugs. / Casini, M. (2024). The use of human induced pluripotent stem cell-derived atrial cardiomyocytes for studying arrhythmia mechanisms [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/204142
|
59 |
Influência da idade e do sexo na frequência cardíaca, nas arritmias cardíacas e nos distúrbios da condução atrioventricular em indivíduos assintomáticos sem evidência de doença cardíaca / Influence of age and sex on heart rate, cardiac arrhythmias and atrioventricular conduction disturbances in asymptomatic individuals without evidence of heart diseasePaula, Rogério Silva de 14 November 2002 (has links)
Há escassos estudos sobre a monitorização eletrocardiográfica ambulatorial em casuísticas brasileiras de indivíduos assintomáticos submetidos ao exame clínico. Com a finalidade de avaliar a freqüência cardíaca, as arritmias cardíacas, e os distúrbios atrioventriculares de condução, foram estudados 625 indivíduos assintomáticos, com exame clínico normal. A idade variou de 15 a 83 (média 42, desvio padrão 11,9) anos; 276 (44,2%) eram homens e 349 (55,8%) mulheres. Os indivíduos foram submetidos ao exame clínico, que incluiu história, exame físico e avaliação laboratorial, além da monitorização eletrocardiográfica ambulatorial de 24 h. Foram estudadas as variáveis obtidas na monitorização eletrocardiográfica ambulatorial nas 24 h de gravação e nos períodos das 6h às 22h, e das 22h às 6h em relação às variáveis do exame clínico-laboratorial. Para a análise dos dados, depois da estatística descritiva, as variáveis contínuas foram examinadas com o emprego da correlação canônica, da regressão linear simples e da regressão linear múltipla. As variáveis categóricas foram analisadas por meio da regressão logística. A freqüência cardíaca mínima nas 24h e no período das 22h às 6h elevou-se com o aumento da idade apenas nos homens. A idade foi a principal influência nas variáveis de freqüência cardíaca na correlação canônica (0,55; p<0,01). A freqüência cardíaca máxima nas 24h e a freqüência cardíaca média nas 24h diminuíram com o aumento da idade. A freqüência cardíaca mínima nas 24h aumentou com a idade em homens e mulheres. A freqüência cardíaca média das 22h às 6h elevou-se com o aumento da idade nos homens e diminuiu nas mulheres. A freqüência cardíaca máxima no eletrocardiograma de esforço não demonstrou correlação com a duração do exercício. A freqüência cardíaca média nas 24 h, das 6h às 22h e das 22h às 6h aumentaram com o aumento do índice de massa corpórea. As arritmias supraventriculares ocorreram em 509 (81%) indivíduos. As extra-sístoles supraventriculares variaram de 1 a 3694 (média de 66,6; desvio padrão de 314,4 e mediana de 5). As arritmias ventriculares ocorreram em 399 (64%) indivíduos. As extra-sístoles ventriculares variaram de 1 a 24.900 (média de 214,8; desvio padrão de 1491,7 e mediana de 3). O bloqueio atrioventricular de segundo grau Mobitz I ocorreu em 2,2% dos indivíduos. A presença de bloqueio atrioventricular de segundo grau Mobitz I revelou associação com o aumento dos triglicérides e com a freqüência cardíaca no eletrocardiograma de repouso menor que 60 batimentos por minuto. As arritmias supraventriculares e ventriculares, embora comuns, foram pouco freqüentes. Os bloqueios atrioventriculares foram pouco freqüentes; entretanto demonstrou-se associação entre bloqueios atrioventriculares e hipertrigliceridemia e com a freqüência cardíaca em repouso inferior a 60 batimentos por minuto. A freqüência cardíaca mínima nas 24h, das 6h às 22h e das 22h às 6h modifica-se com o aumento da idade, modificação essa que foi diferente nos homens e nas mulheres, sem que, entretanto tenha ficado demonstrada relação com a duração do exercício no eletrocardiograma de esforço. Em conclusão, a freqüência cardíaca mínima e máxima se modificaram com o aumento da idade, de modo diferente em homens e mulheres e sofreram influência da massa corpórea. As arritmias foram freqüentes, de baixa densidade e a freqüência aumentou com a idade. A freqüência de distúrbios da condução atrioventricular aumentou com a idade e com o aumento dos triglicérides. / There are few studies on ambulatory electrocardiographic monitoring in brazilian asymptomatic individuals without heart disease. To study heart rate, cardiac arrhythmias, and atrioventricular conduction disturbances, we evaluated 625 asymptomatic individuals with normal clinical examination. The age ranged between 15-83 (mean 42, standard deviation 11,9) years; 276 (44,2%) were men and 349 (55,8%) women. The individuals were submitted to clinical examination, including clinical history, physical examination, laboratory evaluation, and continuous 24h ambulatory electrocardiographic monitoring. After the descriptive statistics, the continuous variables were examined with canonic correlation, simple linear regression and multiple linear regression. The categorical variables were analyzed by logistic regression. The minimum heart rate, during the 24h-period and of the 6h-22h period, increased with aging only in men. The age was the main influence on heart rate on canonic correlation (0,55; p<0,01). The maximum and mean heart rate in 24h decreased with aging. The minimum heart rate in 24h increased with the age in men and women. The mean heart rate from 22h to 6h increased with advancing of age in men and decreased in women. The maximum heart rate and the duration of exercise in the stress electrocardiographic examination did not demonstrate correlation with the heart rate on ambulatory electrocardiographic monitoring. The mean heart rate during 24h period, 6h to 22h period and 22h to 6h periods increased with the elevation of the body mass index. Supraventricular arrhythmia occurred in 509 (81%) individuals. Isolated supraventricular arrhythmia rate varied from 1 to 3694 (mean 66,6; standard deviation 314,4 and median of 5) beats. Ventricular arrhythmias were detected in 399 (64%) individuals. The ventricular arrhythmia rate varied from 1 to 24900 (mean 214,8; standard deviation 1491,7; median of 3) beats. Second-degree atrioventricular block, Mobitz I, occurred in 2,2% of the individuals. Second-degree atrioventricular block, Mobitz I, was associated with to the increase of serum triglycerides and the heart rate in the under 60 beats per minute on the rest electrocardiogram. The supraventricular and ventricular arrhythmias were common but a low frequency. The atrioventricular blocks were infrequent. The minimum heart rate in the periods of 24h, from 6 to 22h and from 22h to 6h was modified by aging, but occurred differently in men and women, without demonstrating any relation to the duration the exercise. In conclusion, the minimum and maximum heart rate were modified with the increase of the age, in a different fashion in men and women, and influence of the body mass index. Arrhythmias were frequent, but had low density and increased with the age. The atrioventricular conduction block increased with the increase of age and triglycerides.
|
60 |
Isquemia silenciosa e arritmias ventriculares são preditores independentes de evenos no pós-infarto do miocárdio de baixo riscoSobral Filho, Dário Celestino January 2003 (has links)
pós-infarto agudo do miocárdio (IAM) têm mostrado baixo valor preditivo positivo quando estudados isoladamente. A possibilidade da Eletrocardiografia Dinâmica de 24 horas (ECGD) fornecer dados referentes a isquemia silenciosa (IS), arritmias ventriculares e modulação autonômica do coração pelo estudo da variabilidade da freqüência cardíaca (VFC), levou o autor a empregar este método em pacientes acometidos de IAM com o objetivo de avaliar se estas três variáveis estariam relacionadas a presença de eventos desfavoráveis em evolução a médio prazo. Material e Métodos – Foram selecionados 91 pacientes acometidos de um primeiro IAM não-complicado e realizados exames de ECGD de 24 h por dois dias consecutivos, antes da alta hospitalar. Os parâmetros pesquisados nos exames foram: isquemia silenciosa, identificação e quantificação de arritmias ventriculares e determinação dos índices de VFC pelos métodos do domínio do tempo e do mapa de retorno tridimensional. Foram considerados como desfechos: re-infarto, angina instável, taquicardia ventricular sustentada e morte. Resultados – No seguimento médio de 27,7 meses (DP=15,45), 23 (25%) dos pacientes apresentaram eventos, sendo nove fatais. Os eventos foram mais freqüentes entre os pacientes que apresentaram extra-sístoles ventriculares ≥10/hora (p=0,01) e também naqueles com IS (p=0,02). Em modelo de análise multifatorial, a presença de dislipidemia elevou o valor preditivo positivo dessas variáveis. Nenhum dos índices de VFC esteve significativamente relacionado ao surgimento de eventos. Conclusões – Em pacientes pós-IAM de baixo risco, a presença de arritmias ventriculares freqüentes ou de isquemia silenciosa está relacionada a um prognóstico desfavorável. O estudo da VFC não mostrou utilidade na estratificação de risco destes pacientes. / Introduction and objective – The noninvasive methods used in post-acute myocardial infarction (AMI) risk stratification have been shown to have a low predictive value when studied in isolation. The possibility that ambulatory electrocardiographic monitoring (AEM) may provide data on silent ischemia (SI), ventricular arrhythmias (VA) and autonomic modulation of the heart through the study of heart rate variability (HRV) led the present author to use this method in AMI patients with the aim of assessing whether these three variables could be related to the presence of unfavorable events in the medium term follow-up. Methods – Ninety-one patients with a first, uncomplicated AMI were selected and submitted to AEM for two consecutive days prior to discharge from the hospital. The parameters studied in the examination were as follows: presence of SI, identification and quantification of VA and determination of the HRV indices by the time domain and three-dimensional return map methods. The following were regarded as outcomes: new AMI, unstable angina, sustained ventricular tachycardia and death. Results – In the mean follow-up of 27.7 months (SD=15.45), 23 (25%) of the patients presented events, nine of which were fatal. Events occurred most frequently in the patients who presented ventricular premature contractions >= (p=0.01) and also in those with SI (p=0.04). In the multifactorial analysis the presence of dislipidemia raised the positive predictive value of these variables. None of the HRV indices was significantly correlated with the occurrence of events. Conclusions – In low-risk post-AMI patients the presence of frequent ventricular arrhythmias or silent ischemia is associated with an unfavorable prognosis. The study of HRV was not shown to be useful in the risk stratification of these patients.
|
Page generated in 0.051 seconds