• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 5
  • 5
  • 5
  • 5
  • 5
  • 1
  • Tagged with
  • 110
  • 55
  • 33
  • 30
  • 30
  • 27
  • 24
  • 23
  • 18
  • 16
  • 15
  • 14
  • 14
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação do destorque do parafuso protético de diferentes tipos de conexões com coroas longas

Rocha, Elissa Almeida 26 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-06-26T12:34:48Z No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T20:35:48Z (GMT) No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) / Made available in DSpace on 2017-08-07T20:35:48Z (GMT). No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) Previous issue date: 2014-08-26 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar a influência de diferentes conexões no destorque do parafuso Neotorque sobre implantes com proporção coroa - implante (2:1), estudo in vitro, após ciclagem mecânica. Trinta implantes de 9 mm x 3,75 mm (Neodent®-Curitiba, Paraná, Brasil) foram utlizados, sendo 10 de cada tipo de conexão (CM,HE, HI) com seus respectivos munhões universais: (CM) ( 3,3/6/3,5), HE e HI ( 4,5,6,3) (Neodent®-Curitiba, Paraná, Brasil). Os implantes foram inseridos individualmente em resina acrílica (JET, Clássico, São Paulo, Brasil) com auxílio de um cilindro calcinável padronizado ( 2,5x1,5). O torque nos parafusos foi feito com torquímetro digital (Lutron TQ – 680, Impac, São Paulo), o grupo HE recebeu 30 N.cm, o grupo CM 15 N.cm e o grupo HI 20N.cm. Posteriormente a aplicação do torque, as coroas foram posicionadas sobre os pilares protéticos com vaselina sólida (Farmax, Divinópolis, Brasil) e em seguida foram submetidos à ciclagem mecânica (Simulador de Fadiga Mecânica, ERIOS, modelo ER – 11000), com aplicação de uma carga de 120N, 75 ciclos/s por 1.000.000 ciclos a 1 Hz, submersos em água destilada. Por fim, o destorque foi mensurado com o auxílio de um torquímetro digital (Lutron TQ-680, Impac, São Paulo/SP). Os valores de média de destorque (desvio padrão) obtidos após ciclagem mecânica foram: CM - 13,4 (1,83) N.cm, HI – 17 (1,69) N.cm e HE – 25,6 (1,95) N.cm. O teste de ANOVA (p<0,05) mostrou que não houve diferença estatisticamente significante entre os grupos (p=0,526) com relação aos diferentes tipos de conexão pilar - implante e a proporção coroa (2) – implante (1) após ciclagem mecânica. Para avaliar cada grupo independentemente em relação a perda de carga do torque de fechamento após ciclagem mecânica, foi realizada o teste t de student independente (p<0,05), obteve-se resultado estatisticamente significante para perda de torque inicial dentro de cada grupo: CM (0,022), HI (0,00) e HE (0,00). Concluiu-se que o tipo de conexão pilar - implante e da proporção coroa – implante (2:1) não influenciou na perda de torque após a ciclagem mecânica; a ciclagem mecânica influenciou na perda de torque dentro de cada grupo de conexão pilar – implante. / The aim of this study was to evaluate the influence of different connections in detorque Neotorque screw implant with crown ratio - implant (2:1), in vitro study, after mechanical cycling. Thirty of 9 mm x 3.75 mm (Neodent®-Curitiba, Paraná, Brazil) were utlizados implants, 10 of each connection type (CM, HE, HI) with their universal posts: (CM) ( 3, 3/6 / 3,5), HE and HI ( 4,5,6,3) (Neodent®-Curitiba, Paraná, Brazil). The implants were inserted individually in acrylic resin (JET, Classic, São Paulo, Brazil) using a standardized burn-cylinder ( 2,5x1,5). The torque on the bolts was done with digital torque meter (Lutron TQ - 680, Impac, São Paulo), the HE group received 30 N.cm, the CM group and 15 N.cm the HI group 20N.cm. Subsequently the application of torque, the crowns were placed on the abutments with petrolatum (Farmax, Divinópolis, Brazil) and then were subjected to mechanical cycling (Simulator Mechanical Stress, Erios, ER Model - 11000), with application of a 120N load, 75 cycles / sec per 1 million cycles at 1 Hz, immersed in distilled water. Finally, the detorque was measured with the aid of a digital torque meter (Lutron TQ-680, Impac, São Paulo / SP). The (standard deviation) values of average detorque obtained after mechanical cycling were: CM - 13.4 (1.83) N.cm, HI - 17 (1.69) and HE N.cm - 25.6 (1, 95) N.cm. The ANOVA test (p <0.05) showed no statistically significant difference between groups (p = 0.526) with respect to different types of abutment connection - implant and the crown ratio (2) - implant (1) after cycling mechanics. To evaluate whether each group compared to the pressure drop in torque after mechanical closure cycling, independent Student t (p <0.05) was performed, there was a statistically significant result for loss of initial torque in each group : CM (0.022), HI (0.00) and HE (0.00). It was concluded that the type of abutment connection - implant and crown ratio - implant (2: 1) no effect on the loss of torque after mechanical cycling; mechanical cycling effect on the loss of torque within each group of connection pillar - implant.
92

Cimentos resinosos convencionais e autoadesivos = caracterização das partículas de carga, ultramorfologia e resistência da união resina-dentina / Conventional and self-adhesive resin cements : filler particles characterization, ultramicromorphology and dentin-resin bond strenght

Aguiar, Thaiane Rodrigues 18 August 2018 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T10:52:55Z (GMT). No. of bitstreams: 1 Aguiar_ThaianeRodrigues_D.pdf: 24572936 bytes, checksum: 8141f58fcbce6835d1091f52127552a7 (MD5) Previous issue date: 2011 / Resumo: O emprego dos cimentos resinosos na fixação de peças protéticas têm sido avaliado em muitos estudos, entretanto, trabalhos que simulem os desafios presentes na cavidade bucal e o comportamento a longo prazo dos cimentos resinosos autoadesivos ainda são escassos na literatura. Diante disso, o presente estudo teve como objetivo: 1) verificar a composição inorgânica das partículas de carga e caracterizá-las quanto ao tipo e morfologia; 2) analisar a ultramorfologia da interface de união dentina-cimento resinoso através da microscopia confocal por varredura a laser e da microscopia eletrônica de varredura (MEV); 3) avaliar o efeito do armazenamento por 1 ano ou da ciclagem mecânica (50.000 ciclos) na resistência de união dentina-cimento resinoso. Quatro cimentos resinosos foram avaliados: dois autoadesivos (RelyX Unicem, 3M ESPE e Clearfil SA Luting, Kuraray Medical Inc.) e dois convencionais (RelyX ARC/Adper Scotchbond Multi-Purpose Plus, 3M ESPE e Clearfil Esthetic Cement/Clearfil DC Bond, Kuraray Medical Inc.). Para analisar os principais componentes inorgânicos e avaliar as características das partículas de carga, o conteúdo orgânico dos cimentos resinosos foi removido por solventes orgânicos e as amostras analisadas em MEV/EDX (Espectroscopia de energia dispersiva por raios-X). Terceiros molares humanos foram utilizados na avaliação da ultramorfologia da interface dentina-cimento resinoso e no ensaio de resistência de união à dentina. Na análise da ultramorfologia da área de união, corantes (fluoresceína e rodamina) foram previamente adicionados aos materiais estudados para possibilitar a obtenção das imagens. Para o ensaio de resistência de união, discos de resina composta indireta foram confeccionados visando simular as restaurações indiretas. Após a cimentação, os dentes restaurados foram submetidos a três tratamentos e ao ensaio de microtração: 1- espécimes testados após 24 h (grupo controle); 2- ciclagem mecânica e em seguida testados; 3- armazenados em saliva artificial por 1 ano na forma de "palitos" e testados. Os dados obtidos a partir do ensaio de resistência de união foram analisados estatisticamente (ANOVA e teste Tukey, p<0,05). Nos outros dois estudos, a análise descritiva dos dados obtidos a partir das imagens microscópicas foi realizada. Na avaliação MEV/EDX notou-se elevado conteúdo de silício em todos os materiais. O cimento RelyX ARC apresentou partículas de carga esféricas e irregulares, enquanto os outros materiais demonstraram partículas com formato irregular. Nas fotomicrografias, a hibridização dentinária somente foi observada para os sistemas de cimentação convencional. No ensaio de resistência de união, os tratamentos não influenciaram a resistência de união dos cimentos resinosos à dentina. Os cimentos autoadesivos apresentaram médias de resistência de união significantemente superiores aos chamados convencionais. Embora os materiais avaliados apresentem partículas de carga com distintas composições inorgânicas e interagem com a dentina através de diferentes mecanismos, os tratamentos de envelhecimentos propostos não reduziram a resistência de união à dentina, quando comparados ao grupo controle. Os cimentos autoadesivos não formam camada híbrida na dentina intertubular, nem tags de resina nos túbulos dentinários, entretanto, apresentam partículas de carga com maior tamanho e demonstraram os maiores valores médios de resistência de união à dentina entre os cimentos estudados / Abstract: Resin luting materials to fixed prosthetic restorations have been evaluated in many studies, however, little is known about self-adhesive resin cements, mainly involving long-term durability and when these materials have been submitted to challenges of oral environment. Thus, the purpose of this study was: 1- to verify the filler particles components and to characterize them according to type and morphology; 2- to analyze the ultramorphology of the dentin-resin interfaces using confocal laser scanning microscopy and scanning electron microscopy (SEM) and 3- to evaluate the effect of the storage for 1 year or the mechanical cycling (50.000 cycles) on bond strength of resin cements to dentin. Four resin cements were used in this study: two self-adhesive resin cements (RelyX Unicem, 3M ESPE and Clearfil SA Luting, Kuraray Medical Inc.) and two conventional resin cements (RelyX ARC/Adper Scotchbond Multi- Purpose Plus, 3M ESPE and Clearfil Esthetic Cement/Clearfil DC Bond, Kuraray Medical Inc.). For indentifying the main inorganic components and to evaluate the filler particles characteristics, the organic phase of resin cements was removed using organic solvents and the sample was analyzed by SEM/EDX (Energy-dispersive X-ray spectroscopy). Human third molars were used for micromorphology analysis of resin-dentin interfaces and microtensile bond strength test. For micromorphology analyses of resin-dentin interfaces, two fluorescent dyes (fluorescein and rhodamine B) were incorporated into the materials previously. For microtensile bond strength, pre-polymerized resin discs were prepared to simulate indirect restorations. After bonding procedures, the restored teeth were submitted to three treatments: 1- control group (tested 24 h after specimen preparation); 2- tested after mechanical cycling; 3- beams were storage for one year in artificial saliva and tested. Bond strength data were statistically analyzed by two-way ANOVA and Tukey test (?<0.05). Qualitative analysis was performed for two other studies using microscopic images. For SEM/EDX measurements, high amount of silicon was identified for all cements. The resin cement RelyX ARC showed spherical and irregular particles, while other cements presented irregular shape fillers. Hybrid layer formation was observed only for conventional resin cements in micromorphology analyses. For microtensile test, the treatments did not reduce the bond strength between dentin-resin cement. Self-adhesive resin cements provide significantly higher bond strength than those conventional materials. Despite the resin cements showed filler particles with differences in the inorganic composition and different bonding mechanisms, the mechanical cycling and storage for one year did not affect the bond strength to dentin when it was compared to control group. The self-adhesive resin cements showed no hybrid layer formation in intertubular dentin and nor resin tags in the dentinal tubules were detected. However, these materials showed the biggest filler particles and higher bond strength to dentin than conventional resin cements studied / Doutorado / Dentística / Doutor em Clínica Odontológica
93

Influência do tratamento de superfície em diferentes substratos na resistência de união à cimento resinoso autoadesivo /

Almeida, Cláudia Cristina Miranda de Souza. January 2019 (has links)
Orientador: Paula Carolina Komori de Carvalho / Coorientador: Rodrigo Othávio de Assunção e Souza / Banca: Carolina Machado Martinelli Lobo / Banca: Eduardo Miyashita / Resumo: As reabilitações orais com próteses fixas na Odontologia passaram por grande evolução ao serem estabelecidos e firmados os conceitos de adesão química. A alta demanda estética desses tratamentos faz com que as cerâmicas que são materiais altamente biocompatíveis e com ótimas propriedades mecânicas, sejam amplamente utilizadas nas reabilitações orais. Nas próteses sobre implantes, o processo de cimentação de restaurações cerâmicas acontece sobre conexões metálicas em titânio (Ti), cobalto-cromo (CoCr) ou infra-estruturas personalizadas em zircônia (Zr). O processo de cimentação necessita de algumas etapas para promover o tratamento de superfície das restaurações indiretas e variam de acordo com a especificidade de cada substrato. O objetivo deste estudo foi avaliar a influência do tratamento de superfície em diferentes substratos de conexões protéticas utilizando primer e sistema adesivo universal contento o monômero funcional 10-MDP na resistência de união à cimento resinoso autoadesivo, por meio de teste mecânico de cisalhamento. Foram confeccionadas 120 amostras (n= 40 de Ti, CoCr e Zr) as quais foram incluidas em blocos de resina acrílica. As amostras foram subdivididas em 12 grupos (n=10), 3 grupos representam o controle e não tiveram a superfície tratada, os demais grupos tiveram a superfície tratada com primer monocomponente ou sistema adesivo universal contendo 10-MDP. Em seguida foi confeccionado um cilíndro de cimento resinoso (2mm de altura X 2,37mm de diâmetro) com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Oral rehabilitations with fixed prostheses in Dentistry had grown with great evolution when the concepts of chemical adhesion were established and signed. The high aesthetic demand of these treatments makes Ceramics, that are highly biocompatible materials and with good mechanical properties, widely used in oral rehabilitation. In implant prostheses, the process of cementation happens between ceramic restorations on metallic connections in titanium (Ti) and / or cobalt chromium (CoCr) or custom zirconia (Zr) infrastructures. During the cementing process of ceramic restorations some surface treatment steps are required, these steps varying according to the type of specific ceramics. The aim of this study was to evaluate the influence of surface treatment on different substrates of prosthetic connections using primer and universal adhesive system containing 10-MDP functional monomer on bond strength to self-adhesive resin cement by mechanical shear test. One hundred and twenty samples (n = 40 Ti, CoCr and Zr) were made and included in blocks of acrylic resin. The samples were subdivided into 12 groups (n = 10), 3 groups represent the control and did not have the surface treated, the other groups had the surface treated with single component primer or universal adhesive system containing 10-MDP. Then a resin cement cylinder (2mm height X 2,37mm diameter) was made with the aid of a teflon device to measure the exact dimensions. Twenty four hours after the cylinders were made, the... (Complete abstract click electronic access below) / Mestre
94

Influência dos cimentos resinosos e sistemas cerâmicos na translucidez e estabilidade de cor de restaurações laminadas / Influence of resin cements luting and ceramic systems in the translucency and color stability of veneers

Silami, Francisca Daniele Jardilino 31 March 2017 (has links)
O objetivo desse estudo foi avaliar o grau de conversão, a estabilidade de cor e translucidez de cimentos resinosos para cimentação de laminados cerâmicos em duas espessuras, submetidos a diferentes protocolos de envelhecimento. Foram utilizados 270 incisivos bovinos hígidos, cujas porções radiculares foram cortadas e as porções coronárias foram incluídas em matriz de PVC (25mm de diâmetro) com resina acrílica. As faces vestibulares foram planificadas até a dentina. Foram confeccionados 240 corpos-de-prova em cerâmica prensada (IPS e-max Press e IPS e- maxZirpress, IvoclarVivadent), em duas espessuras (0,5 mm e 1,0 mm), que foram separados aleatoriamente em dois grupos, segundo o tipo de cimento resinoso utilizado para fixação: fotoativado (Variolink II, Ivoclar/Vivadent) ou dual (Rely U 200, 3M ESPE). Após a cimentação, todas as amostras foram mantidas em estufa a 37°C por 24h, após o qual foram realizadas as leituras de cor e translucidez iniciais (Vita EasyShade, VITA). Em seguida, as amostras foram subdivididas em três grupos (n=10) de acordo com o envelhecimento a que foram submetidos: Controle sem envelhecimento; imersão em água destilada por 1 ano e fadiga termomecânica (1.200.000 ciclos, frequência de1,3Hz e ciclagem térmica de 5°C/37°C/55°C). Como controle, foram obtidos 30 corpos-de-prova de cada cimento resinoso (0,5mm) e 30 dentes foram planificados e submetidos aos mesmos processos de envelhecimento, após o qual leituras finais foram realizadas. Foram analisados também o grau de conversão dos cimentos polimerizados através das restaurações (FTIR) e a linha de cimentação em cada um dos grupos (n=3), antes e depois do envelhecimento. Para isso, as amostras, selecionadas aleatoriamente, foram seccionadas no sentido longitudinal e analisadas em estereomicroscópio de dupla coordenada (Nikon Measurescope). Os dados de estabilidade de cor (&Delta;E), translucidez, grau de conversão e linha de cimentação foram submetidas à análise estatística (3-way ANOVA, Tukey, p<0,05). O cimento autoadesivo apresentou maior grau de conversão que o fotoativado (p<0,05) quando utilizada a cerâmica Zirpress, mas produziu maior alteração de cor (p<0,05) e menor translucidez nas restaurações de E-maxPress de 0,5mm. A ciclagem termomecânica não foi significante para alterações óticas dos sistemas cerâmicos testados. Conclui-se que a espessura do laminado cerâmico não altera o grau de conversão dos cimentos resinosos e o tipo de cimento resinoso influencia a estabilidade de cor das restaurações cerâmicas quando submetido ao envelhecimento com água destilada. / The aim of this study is to evaluate the degree of conversion, color stability and translucency of resin cement for luting ceramic veneers with two thicknesses submitted to different aging protocols. Two hundred and seventy bovine incisors were used, which had the root cut, and the coronal were embedded in acrylic resin into PVC rings (25mm diameter). The buccal surface was flattened until dentin. Two hundred and forty pressed ceramic veneers (IPS e-max Press and IPS e-max ZirPress, IvoclarVivadent) were obtained, in two thicknesses (0,5 mm and 1.0 mm), that were randomly separated into two groups according to the type of resin cement used for luting: light-cured (Variolink II, Ivoclar / Vivadent) or dual cured (Rely U 200, 3M ESPE). After the cementation, all samples were maintained at 37 °C for 24 h; after first color and translucency readings (Vita EasyShade, VITA) were made. The samples were separated into 3 groups (n=10) according to the aging that was submitted: control without aging, immersion in distilled water for one year and thermomechanical cycling (1.200.000 cycles, frequency of 1,3Hz and thermal cycling of 5°C/37°C/55°C). As the control group, 30 samples of each resin cement (0,5 mm) and flattened teeth were obtained and submitted to the same aging protocols. After tests, the final color and translucency readings were taken. The degree of conversion of resin cements through veneer restoration, and the cement film thickness (n=3) for each group were analyzed (FTIR), before and after aging. For this, the samples were randomly selected, sectioned longitudinally and examined by a stereomicroscope (Nikon Measurescope). The results of color stability (&Delta;E), translucency, degree of conversion and cement film thicknesses were statistically analyzed (3-way, ANOVA, Tukey, p<0.05). The self-adhesive cement showed the higher degree of conversion than light-activated luting cement (p<0.05) when Zirpress ceramic was used, but produced higher color change (p<0.05) and lower translucency in 0.5mm E-maxPress restorations. The thermomechanical cycling was not significant for optical changes of tested ceramic systems. It was concluded that the thickness of ceramic veneers didnt alter the degree of conversion of resin cement and the type of resin cement has influenced the color stability of ceramic restorations when submitted to water aging.
95

Avaliação da resistência ao cisalhamento da zircônia após diferentes tratamentos de superfície / Evaluation of shear bond strength of zirconia after different surface treatments

Santos, Livia Aguiar 06 May 2011 (has links)
Cerâmicas de alto conteúdo cristalino, como a zircônia policristalina tetragonal estabilizada por ítrio (Y-TZP), apresentam ótimas propriedades mecânicas quando comparadas às cerâmicas convencionais, sendo cada vez mais empregadas como materiais restauradores indiretos. Entretanto, seu sucesso também depende da formação de uma união confiável com os agentes de cimentação. Porém, o aumento do conteúdo cristalino modificou as características de adesão entre cerâmica e cimento resinoso, não existindo um protocolo de cimentação bem estabelecido na literatura. Portanto, este estudo teve como objetivo avaliar o efeito na resistência ao cisalhamento de diferentes tratamentos de superfície sobre a zircônia, utilizando dois cimentos resinosos, assim como avaliar as possíveis diferenças no modo das fraturas. Cento e vinte amostras retangulares de zircônia foram incluídas em resina acrílica e divididas em 12 grupos (n=10), de acordo com os tratamentos de superfície e os cimentos (Panavia F e Rely X U100). Para cada cimento, os grupos experimentais foram formados da seguinte maneira: RU e Pa - controle (sem nenhum tratamento de superfície); ApRU e ApPa (aplicação do Alloy Primer); MzRU e MzPa (aplicação do Metal/Zircônia Primer); JatRU e JatPa (jateamento com partículas de óxido de alumínio de 50µm); JatApRU e JatApPa (jateamento e aplicação de Alloy Primer); JatMzRU e JatMzPa (jateamento e aplicação do Metal/Zircônia Primer). Os corpos de prova foram armazenados em água destilada à temperatura de 37°C por 24 horas, antes do teste de cisalhamento em uma máquina de ensaio universal (EMIC). Os valores foram submetidos primeiro a ANOVA a um critério (resistência ao cisalhamento) e teste de Tukey (p 0,05), independente do tratamento e do sistema de cimentação. Em seguida, ANOVA a dois critérios (tratamento de superfície e sistema de cimentação) e o teste de Tukey foram aplicados para observar com maior precisão a interação entre cimento e tratamento de superfície. Os resultados apresentados foram: RU - 11,71a, ApRU - 21,49b,e, MzRU - 30,38c,d, JatRU - 34,40c, JatApRU - 30,66c,d, JatMzRU - 38,06c, Pa - 11,35a, ApPa - 11,98a, MzPa - 11,46a, JatPa - 33,50c, JatApPa - 23,14b,d,e, JatMzPa - 18,66a,e. Por meio dos resultados obtidos foi possível concluir que a resistência ao cisalhamento pode ser melhorada ao utilizar o jateamento com partículas de óxido de alumínio e, para o RelyX U100, somente a aplicação do Metal/Zircônia Primer resultou em valores de adesão comparavéis ao tratamento mecânico. O cimento RelyX U100 apresentou maior resistência de união quando comparado ao Panavia F. / High crystalline content ceramics, such as yttria stabilized tetragonal zirconia polycrystal (Y-TZP), show great mechanical properties when compared to conventional ceramics, being increasingly used as indirect restorative materials. However, its success also depends on the reliable bond formation with luting agents. Though, the high crystalline content modified the adhesiveness between ceramic and resin cement although there isnt any cementing protocol established in literature. Therefore, the purpose of this study was to evaluate the effect of the shear bond strength after different surface treatments on the zirconia, using two resin cements and to evaluate possible differences in fracture modes. One hundred and twenty rectangular samples of zirconia were embedded in acrylic resin and divided into 12 groups (n=10) according to the surface treatments and the cements (Panavia F and RelyX U100). For each cement, the experimental groups were formed as follow: RU and Pa - control (no surface treatment); ApRU and ApPa (application of Alloy Primer); MzRU e MzPa (application of Metal/Zirconia Primer); JatRU and JatPa (air abrasion with 50µm Al2O3 particles); JatApRU and JatApPa (air abrasion and application of Alloy Primer); JatMzRU and JatMzPa (air abrasion and application of Metal/Zirconia Primer). The specimens were stored in distilled water at 37°C for 24 hours prior to the shear bond strength test in a universal testing machine (EMIC). The data were first analyzed by one-way ANOVA (shear bond strength) and Tukey test (p<0.05), regardless of the treatment and the luting system. Then two-way ANOVA (surface treatment and luting system) and the Tukey test were applied in order to observe more accurately the interaction between cement and surface treatments.The results presented were: RU 11.71a, ApRU 21.49b,e, MzRU 30.38c,d, JatRU 34.40c, JatApRU 30.66c,d, JatMzRU 38.06c, Pa 11.35a, ApPa 11.98a, MzPa 11.46a, JatPa 33.50c, JatApPa 23.14b,d,e, JatMzPa 18.66a,e. Based on the results obtained, it was possible to conclude that the shear bond strength can be improved when air abrasion was used with aluminum-oxide particles and for the RelyX U100, only the application of Metal / Zirconia Primer resulted in adhesion values comparable to mechanical treatment. The RelyX U100 cement showed higher bond strength when compared to Panavia F.
96

Estudo do uso de agregado reciclado de resíduos de construção e demolição em misturas solo-agregado / Study of the use of recycled aggregate of construction and demolition waste in soil-aggregate mixtures

Orioli, Monigleicia Alcalde 24 July 2018 (has links)
A construção civil gera impactos ambientais que merecem atenção especial, uma vez que é uma das áreas que mais produz resíduos dentre as atividades econômicas. Os agregados reciclados de resíduos de construção e demolição podem ser utilizados em diversas áreas, apresentando desempenhos mecânico e hidráulico adequados quando comparados aos agregados naturais. Esta pesquisa consiste em estudar a viabilidade o uso de agregado reciclado misto (ARM) e misturas solo-ARM como materiais geotécnicos em camadas de bases e sub-bases de pavimentos. Para isso, foram realizados ensaios de caracterização física e comportamento mecânico. Para comparação, foram estudados também um agregado natural (AN) e uma mistura de solo-AN. Os resultados mostraram que a energia de compactação teve efeito positivo sobre o comportamento do ARM e misturas de solo-ARM. Observou-se ainda que o ARM apresentou ganho de resistência e rigidez devido ao efeito de auto-cimentação. No que se refere à adição de solo, as misturas de solo-ARM apresentaram uma diminuição no valor de CBR em relação a misturas compostas exclusivamente por ARM, contudo houve um aumento nas demais propriedades mecânicas. Com base nos resultados obtidos, pode-se concluir que o ARM e as misturas solo-ARM apresentam características físicas e comportamento mecânico adequados para uso em camadas de base e sub-base de pavimentos urbanos. / Civil construction generates environmental impacts that deserve special attention, since it is one of the areas that produces the most waste among economic activities. The recycled aggregates of construction and demolition waste can be used in several areas, presenting adequate mechanical and hydraulic performances when compared to natural aggregates. This research consists of studying the feasibility of using recycled mixed aggregate (RMA) and soil-RMA mixtures as geotechnical materials in base and sub-base layers of pavements. For that, tests of physical characterization and mechanical behavior were carried out. For comparison, a natural aggregate (NA) and a soil-NA mixture were also studied. The results showed that the compaction energy had a positive effect on the behavior of RMA and soil-RMA mixtures. It was also observed that the RMA showed strength gain and stiffness due to the self-cementing properties. Concerning soil addition, the soil-RMA mixtures presented a decrease in the CBR value in relation to mixtures exclusively composed by RMA, but there was an increase in the other mechanical properties. Based on the results obtained, it can be concluded that the RMA and the soil-RMA mixtures present physical characteristics and mechanical behavior suitable for the use in base and sub-base layers of urban pavements.
97

Influência dos cimentos resinosos e sistemas cerâmicos na translucidez e estabilidade de cor de restaurações laminadas / Influence of resin cements luting and ceramic systems in the translucency and color stability of veneers

Francisca Daniele Jardilino Silami 31 March 2017 (has links)
O objetivo desse estudo foi avaliar o grau de conversão, a estabilidade de cor e translucidez de cimentos resinosos para cimentação de laminados cerâmicos em duas espessuras, submetidos a diferentes protocolos de envelhecimento. Foram utilizados 270 incisivos bovinos hígidos, cujas porções radiculares foram cortadas e as porções coronárias foram incluídas em matriz de PVC (25mm de diâmetro) com resina acrílica. As faces vestibulares foram planificadas até a dentina. Foram confeccionados 240 corpos-de-prova em cerâmica prensada (IPS e-max Press e IPS e- maxZirpress, IvoclarVivadent), em duas espessuras (0,5 mm e 1,0 mm), que foram separados aleatoriamente em dois grupos, segundo o tipo de cimento resinoso utilizado para fixação: fotoativado (Variolink II, Ivoclar/Vivadent) ou dual (Rely U 200, 3M ESPE). Após a cimentação, todas as amostras foram mantidas em estufa a 37°C por 24h, após o qual foram realizadas as leituras de cor e translucidez iniciais (Vita EasyShade, VITA). Em seguida, as amostras foram subdivididas em três grupos (n=10) de acordo com o envelhecimento a que foram submetidos: Controle sem envelhecimento; imersão em água destilada por 1 ano e fadiga termomecânica (1.200.000 ciclos, frequência de1,3Hz e ciclagem térmica de 5°C/37°C/55°C). Como controle, foram obtidos 30 corpos-de-prova de cada cimento resinoso (0,5mm) e 30 dentes foram planificados e submetidos aos mesmos processos de envelhecimento, após o qual leituras finais foram realizadas. Foram analisados também o grau de conversão dos cimentos polimerizados através das restaurações (FTIR) e a linha de cimentação em cada um dos grupos (n=3), antes e depois do envelhecimento. Para isso, as amostras, selecionadas aleatoriamente, foram seccionadas no sentido longitudinal e analisadas em estereomicroscópio de dupla coordenada (Nikon Measurescope). Os dados de estabilidade de cor (&Delta;E), translucidez, grau de conversão e linha de cimentação foram submetidas à análise estatística (3-way ANOVA, Tukey, p<0,05). O cimento autoadesivo apresentou maior grau de conversão que o fotoativado (p<0,05) quando utilizada a cerâmica Zirpress, mas produziu maior alteração de cor (p<0,05) e menor translucidez nas restaurações de E-maxPress de 0,5mm. A ciclagem termomecânica não foi significante para alterações óticas dos sistemas cerâmicos testados. Conclui-se que a espessura do laminado cerâmico não altera o grau de conversão dos cimentos resinosos e o tipo de cimento resinoso influencia a estabilidade de cor das restaurações cerâmicas quando submetido ao envelhecimento com água destilada. / The aim of this study is to evaluate the degree of conversion, color stability and translucency of resin cement for luting ceramic veneers with two thicknesses submitted to different aging protocols. Two hundred and seventy bovine incisors were used, which had the root cut, and the coronal were embedded in acrylic resin into PVC rings (25mm diameter). The buccal surface was flattened until dentin. Two hundred and forty pressed ceramic veneers (IPS e-max Press and IPS e-max ZirPress, IvoclarVivadent) were obtained, in two thicknesses (0,5 mm and 1.0 mm), that were randomly separated into two groups according to the type of resin cement used for luting: light-cured (Variolink II, Ivoclar / Vivadent) or dual cured (Rely U 200, 3M ESPE). After the cementation, all samples were maintained at 37 °C for 24 h; after first color and translucency readings (Vita EasyShade, VITA) were made. The samples were separated into 3 groups (n=10) according to the aging that was submitted: control without aging, immersion in distilled water for one year and thermomechanical cycling (1.200.000 cycles, frequency of 1,3Hz and thermal cycling of 5°C/37°C/55°C). As the control group, 30 samples of each resin cement (0,5 mm) and flattened teeth were obtained and submitted to the same aging protocols. After tests, the final color and translucency readings were taken. The degree of conversion of resin cements through veneer restoration, and the cement film thickness (n=3) for each group were analyzed (FTIR), before and after aging. For this, the samples were randomly selected, sectioned longitudinally and examined by a stereomicroscope (Nikon Measurescope). The results of color stability (&Delta;E), translucency, degree of conversion and cement film thicknesses were statistically analyzed (3-way, ANOVA, Tukey, p<0.05). The self-adhesive cement showed the higher degree of conversion than light-activated luting cement (p<0.05) when Zirpress ceramic was used, but produced higher color change (p<0.05) and lower translucency in 0.5mm E-maxPress restorations. The thermomechanical cycling was not significant for optical changes of tested ceramic systems. It was concluded that the thickness of ceramic veneers didnt alter the degree of conversion of resin cement and the type of resin cement has influenced the color stability of ceramic restorations when submitted to water aging.
98

Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysis

Lobo, Tamile Rocha da Silva 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.
99

Influência do sistema de cimentação e do modo de ativação na resistência ao push-out de pinos de fibra de vidro / Influence of cementation system and activation mode on push-out bond strength of glass fiber posts

Reinaldo de Souza Ferreira 04 December 2009 (has links)
O objetivo deste estudo foi avaliar a influência do tipo de sistema de cimentação (condicionamento ácido total ou autoadesivo), do modo de ativação (autoativado ou dual), do terço do conduto radicular (cervical, médio ou apical) e da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro cimentados em dentes humanos. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Decorridos sete dias, os condutos foram preparados a uma profundidade de 10mm com brocas padronizadas do sistema dos pinos de fibra (WhitePost DC #2) e aleatoriamente divididos em 4 grupos, conforme o sistema de cimentação e o modo de ativação: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (condicionamento ácido total), ativação dual, (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, autoativado, (G3) RelyX U100 (autoadesivo), dual e (G4) RelyX U100, autoativado. Após uma semana, cada raiz foi seccionada em máquina de corte, originando 6 fatias de 1 mm de espessura (n=60). Antes do ensaio de push-out cada fatia foi fotografada em ambas as faces, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram capturadas para determinação do modo de falha. Para automatizar a determinação da espessura de cimento, foi desenvolvida uma macro no software KS 400. Os dados foram estatisticamente analisados com ANOVA 3 fatores (resistência de união) e teste de Kruskall-Wallis (espessura do cimento). Comparações múltiplas foram realizadas com o teste Student-Newman-Keuls. Análise de regressão, modelo linear, foi empregada para verificar a correlação entre espessura do cimento e resistência de união. Todos os testes foram aplicados com &#945; = 0,05. O fator cimento exerceu influência significativa para a resistência de união (p = 0,0402): o RelyX U100 apresentou a maior média. A ativação dual elevou os valores de resistência de união em comparação ao modo quimicamente ativado (p < 0,0001). Houve diferenças significantes entre os grupos, sendo G1 (22,4 4,0 MPa) > G3 (20,4 3,6 MPa) > G4 (17,8 5,2 MPa) > G2 (13,5 4,3 MPa). O terço do conduto não exerceu influência significativa sobre a resistência adesiva (p = 0,4749). As espessuras dos filmes de cimento foram estatisticamente diferentes nos diferentes terços: cervical (102 45 m) > médio (75 29 m) > apical (52 28m). Não foi observada forte correlação entre os valores de espessura e os de resistência ao push-out (r = - 0,2016, p = 0,0033). O tipo de falha predominante foi a mista, exceto para o G2, que apresentou 74% das falhas na interface cimento-pino. Dessa forma, o cimento autoadesivo apresentou melhor desempenho que o convencional, e ambos os sistemas duais, sobretudo o RelyX ARC, apresentaram dependência da fotoativação para atingirem maiores valores de resistência de união. / The aim of this study was to evaluate the influence of adhesive cementation system approach (total-etch or self-adhesive), activation mode (self-cure or dual-cure), canal third (cervical, middle or apical) and cement thickness on push-out bond strength of glass fiber post bonded on human roots. Forty roots were embebed in epoxy resin and endodontically treated (filled with guta percha and non-eugenol endodontic sealer). Following 7 days, the post spaces were prepared with low-speed post drills provided by the manufacturer (WhitePost DC #2, FGM) at a depth of 10 mm and the roots were randomly divided in 4 groups, according to cementation system and activations mode: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (total-etch), dual-cure (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, self-cure, (G3) RelyX U100 (self-adhesive), dual-cure and (G4) RelyX U100, self-cure. After 7 days, each root was sectioned with water-cooled diamond blade, generating six 1-mm thickness slices (n=60). Before push-out bond strength test, digital images of both sides of the slices were captured with digital camera, in order to measure the post radius and the cement thickness. After mechanical test, new images were captured to evaluate the failure mode. A macro was developed in KS 400 software to speed and standardize the evaluation of cement thickness. Results were analyzed using three-way ANOVA (push-out) and Kruskall-Wallis test (cement thickness). Post-hoc multiple comparisons were performed using the Student-Newman-Keuls test. The correlation between resin cement thickness and bond strength was evaluated with regression analysis, linear model. All tests were performed with significance level set at 0.05. Push-out bond strength was significantly influenced by cement type (p= 0.0402): the RelyX U100 cement presented higher mean value. The dual-activated mode increased the bond strength in comparison to self-activated mode (p < 0.0001). Statically differences were observed between groups: G1 (22.4 4.0 MPa) > G3 (20.4 3.6 MPa) > G4 (17.8 5.2 MPa) > G2 (13.5 4.3 MPa). Bond strength was not affected by post space depth (p = 0,4749). The resin cement thicknesses were significantly different in root thirds: cervical (102 45 m) > middle (75 29 m) > apical (52 28m). No strong correlation between cement thickness and push-out bond strength was observed (r = - 0.2016, p = 0.0033). The main failure mode was mixed, except for G2 (74% adhesive failures at post-cement interface). It was concluded tha the self-adhesive cement showed a better performance than the conventional one, and both dual resin systems, specially the RelyX ARC, presented photo-activation dependence to attain greater adhesive bond strength.
100

Avaliação da adaptação marginal de restaurações cerâmicas inlay após a cimentação

Carvalho, Cristiane Fonseca de [UNESP] 19 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-19Bitstream added on 2014-06-13T20:58:53Z : No. of bitstreams: 1 carvalho_cf_me_sjc.pdf: 1809025 bytes, checksum: bd4ee4f9a60dfdd8304d67de208703e4 (MD5) / O objetivo deste estudo foi avaliar e comparar a adaptação marginal de restaurações, confeccionadas em dois tipos de sistemas cerâmicos: CEREC inLab (VITA) e IPS Empress 2 (Ivoclar-Vivadent) , após a cimentação com cimento resinoso RelyX (3M). Foram preparados 20 pré-molares humanos com cavidade MOD inlay, reproduzidos com silicone de adição, e obtidos modelos em gesso tipo IV, sobre os quais foram confeccionadas as restaurações conforme as recomendações dos fabricantes. Dez inlays no sistema IPS Empress 2 e 10 inlays no sistema CEREC inLab. As restaurações foram cimentadas sob pressão constante de 1,5 Kgf por 10 min, com cimento resinoso, com pré-tratamento. As desadaptações marginais foram avaliadas em MEV, com magnificação de 200x, em 50 pontos eqüidistantes. As médias foram analisadas pelo teste estatístico t(Student) de amostras dependentes.Resultando em uma diferenca estatisticamente significante entre as desadaptaçoes marginais no sistema IPS Empress (93,8'mais ou menos'15,5'mü'm)que se mostraram menores que no sistema CEREC inLab (114,4'mais ou menos'10,6'mü'm). Quando se comparou os valores médios entre as faces proximais (116,51.21,85'mü') e oclusal (112,26'mais ou menos'8,49'mü) do sistema Cerec Inlab, e faces proximais (87,12'mais ou menos'27,98,'mü') e oclusal (100,47'mais ou menos'22,23'mü')do sistema IPS Empress 2, verifica-se que esses valores não diferem estatisticamente. Ainda assim, conclui-se que as médias obtidas são aceitavéis clinicamente. / This study has the proposal to evaluate the marginal adaptation of two system all-ceramic class II inlays one of laboratory-made heat-pressed ceramics (IPS Empress 2) and other computer-aided manufacturing ( CEREC inLab) after cementation with resin cement . Extracted human premolars were prepared to receive mesio occluso distal (MOD) ceramic inlays for 10 IPS Empress restorations and 10 CEREC inLab restorations. The impression material used was a polivinilsyloxane addition silicone by the double impression technique. The impressions of prepared teeth were cast in type IV dental stone. The restaurations were made following the manufacturer's recommendations. The inlays were luted on human premolars with resin cement in accordance with the manufacturer's recommended pré-treatment. The marginal gaps were investigated scanning electron microscopy with magnification of 200x. The results were analyzed by t (student) statistic test.The means marginal gap for IPS Empress 2 wal 93,8'mais ou menos'15,5'mü'm significantly smaller than that od 114,4'mais ou menos'10,6'mü'm calculated a the CEREC in Lab system.The gaps of the inlays at the occlusal margin and of the approximal margin showed no significantly differences in two system. It may be concluded that mensuarement value are clinically acceptable.

Page generated in 0.0551 seconds