• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 195
  • 178
  • 75
  • 20
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 477
  • 273
  • 92
  • 85
  • 58
  • 57
  • 57
  • 46
  • 46
  • 42
  • 42
  • 40
  • 40
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Nefropatia induzida por contraste após tomografia computadorizada

Selistre, Luciano da Silva January 2009 (has links)
Made available in DSpace on 2013-08-07T19:04:27Z (GMT). No. of bitstreams: 1 000423234-Texto+Completo-0.pdf: 1078063 bytes, checksum: 6a299e1c4b16d08e29d7fca46679d196 (MD5) Previous issue date: 2009 / Contrast-induced nephropathy (CIN) is defined as worsening in renal function after administration of parenteral contrast and exclusiona of other causes. CIN is usually manifested as acute non-oliguric renal failures. Cases of CIN are usually defined by a fixed (0. 5 mg/dl) or proportionate (25%) rise in serum creatinine levels 24-48 hours after exposure to the contrast medium. Prevention strategies are based on the correction of factors leading to the development of CIN and are divided into choice of less nephrotoxic contrast (non-ionic); improvement in the patient’s clinical status through hydration; use of drugs that reduce renal vasoconstriction and oxidative stress; and temporary suspension of drugs with nephrotoxic potential or that are hamful in case of reduced glomerular filtration. This review aims on the management recommendations to prevent its occurrence. / A nefropatia por contraste (NIC) é definida como uma piora na função renal que se segue à administração de contraste parenteral, tendo sido excluídas outras causas. A NIC manifesta-se, usualmente, como uma insuficiência renal aguda não oligúrica. Por definição, deve haver um aumento na creatinina basal de 25-50% ou um aumento superior a 0,5 mg/dl de 24 a 48 horas após o uso vascular de contraste. As medidas de prevenção são baseadas na correção dos fatores que levam ao desenvolvimento da NIC e dividem-se em: escolha de agentes de contrastes menos nefrotóxicos (não-iônicos) e utilização de doses menores; melhora no estado clínico do paciente com hidratação; uso de drogas que reduzam vasoconstrição renal e estresse oxidativo; e suspensão temporária de drogas com potencial nefrotóxico ou prejudiciais, no caso de diminuição da filtração glomerular. Essa revisão tem o objetivo de examinar as principais recomendações de manejo para prevenir sua ocorrência.
112

Avaliação do volume de fluxo portal em pacientes esquistossomóticos: Estudo comparativo entre Ressonância Magnética e Ultra-som Doppler / Evaluation of portal blood flow in patients with schistosomiasis: comparative study between magnetic resonance and doppler ultrasound

Leão, Alberto Ribeiro de Souza [UNIFESP] January 2008 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:45:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2008 / Objetivo: Avaliar a concordancia entre o Ultra-som Doppler (USD) e a Ressonancia Magnetica (RM) e a reprodutibilidade inter-observador do USD e RM, na quantificacao do volume de fluxo portal em individuos esquistossomoticos. Metodos: Foi realizado estudo transversal, observacional e auto-pareado, avaliando 21 pacientes portadores de esquistossomose hepato- esplenica, submetidos a mensuracao do fluxo portal atraves da RM (utilizando-se a tecnica Phase-contrast) e USD, por 4 observadores, de forma independente, sendo calculada a concordancia entre os metodos e os observadores, atraves do coeficiente de correlacao intraclasse, teste T-pareado e grau de linearidade de Pearson. Resultados: Observou-se uma baixa concordancia entre os metodos [coeficiente de correlacao intra-classe de 34,5% (IC a 95%)]. A reprodutibilidade inter-observador, na avaliacao pela Ressonancia Magnetica [coeficiente de correlacao intra-classe u 99,2% % (IC a 95%) / coeficiente de Correlacao de Pearson - 99,2% / media do fluxo portal = 0,806] e pelo USD [coeficiente de correlacao intra-classe - 80,6 a 93,0 % (IC a 95%) / coeficiente de Correlacao de Pearson - 81,6 a 92,7% / media do fluxo portal = 0,954; 0,758 e 0,749], foram excelentes. Conclusao: Ha uma baixa concordancia entre o USD e RM na mensuracao do volume de fluxo na veia porta. A RM e o USD sao metodos reprodutiveis na quantificacao do fluxo portal em pacientes portadores de hipertensao porta de origem esquistossomotica, apresentando boa concordancia inter-observador / Purpose: to evaluate the agreement between Doppler Ultrasound (DUS) and Magnetic Resonance Imaging (MRI) and also de reproducibility of both methods in measuring portal volume blood flow in patients with schistosomiasis. Methods: this was a prospective, observational, transversal, auto controlled research design. Twenty-one patients with hepatosplenic schistosomiasis mansoni referred for measurement of portal blood flow by MRI, using phase-contrast technique and Doppler ultra-sonography. The patients were studied independently by four observers and the agreement between both methods and observers was determined using the paired-sample T test, intraclass correlation and Pearson´s correlation coefficient. Results: there was poor agreement between MRI and DUS values (intraclass correlation coefficient 34,5% [CI at 95%]). Nevertheless, inter-observer reproducibility of MRI (intraclass correlation coefficient – 99,2% % [CI at 95%] / Pearson’s correlation coefficient - 99,2% / portal blood flow = 0,806) and DUS measurements (intraclass correlation coefficient - 80,6 to 93,0 % [CI at 95%]/ Pearson’s correlation coefficient - 81,6 to 92,7% / portal blood flow = 0,954; 0,758 and 0,749) were excellent. Conclusion: there is poor agreement between DUS and phase-Contrast MRI technique in measuring portal blood flow volume. Nevertheless, MRI and DUS are reproducible methods for measuring portal blood flow in patients with portal hypertension due to hepatoesplenic schistosomiasis, presenting excellent inter-observer agreement. / BV UNIFESP: Teses e dissertações
113

Análise da penetrabilidade de duas substâncias irrigadoras: estudo em canais simulados / Analysis of penetration two irrigating solutions: a study in simulated canals

Marcus Vinicius Corvelo de Andrade 27 September 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do estudo foi verificar ex vivo a penetração de duas substâncias irrigantes hipoclorito de sódio 5% e Chlor-Xtra (Vista Dental Products, Racine, WI) através da adição de corante em canais simulados de dentes clarificados. Sessenta caninos inferiores unirradiculares humanos foram utilizados. As raízes foram seccionados em 16mm e instrumentadas com limas rotatórias do sistema Protaper até a F2 no comprimento de trabalho de 15mm. As amostras foram submetidas ao processo de clarificação para ficarem transparentes e durante o processo foram criados os canais simulados no terço apical. As raízes foram divididas aleatoriamente em três grupos ( NaOCl 5%, Chlor-Xtra e água) contendo 20 espécime por grupo. As amostras foram irrigadas com 1,5mL de solução contraste( tinta chinesa junto com a solução irrigante do respectivo grupo). E cada amostra foi fotografada e analisada. Os dados foram analisados estatisticamente pelos testes Kruskal-Wallis e Student-Neuman-Keuls. Não houve diferença estatística entre as substâncias irrigantes testadas (p>0,05). A partir da análise dos dados, foi possível concluir que apesar da presença de agentes surfactantes na solução irrigante de Chlor-Xtra não houve uma melhor penetrabilidade nos canais simulados em comparação ao hipoclorito de sódio(NaOCl). / The aim of this work was to asses ex vivo penetration of two irrigation substances sodium hypochlorite 5% and Chlor-Xtra (Vista Dental Products, Racine, WI) by the addition of dye in simulated canals from cleared teeth. Sixty single-rooted human mandibular canines were used. Roots length was standardized to 16 mm and root canal shaping was performed to a working length of 15 mm using Protaper Universal rotary files (Maillefer) up to F2 corresponding to a 25/.08 size/taper. The samples were cleared using clearing technique and and simulated canals were created in apical third at the time of process. Roots were randomly divided into three groups (5% NaOCl, Chlor-Xtra and water) containing 20 specimens per group. Samples were irrigated with 1.5 mL of contrast solution (Chinese ink and irrigating substance of the group). And each sample was photographed and analyzed. Data were statistically analyzed by Kruskal-Wallis and Student-Neuman-Keuls tests. No statistical difference between the tested irrigating solutions was found (p> 0.05). From the data analysis, we conclude that in despite of the presence of surfactants in the irrigating solution Chlor-Xtra did not result better penetration into simulated canals than sodium hypochlorite (NaOCl).
114

Angiografia cerebral em cães (Canis familiaris) / Cerebral angiography in dogs(Canis familiaris)

Veiga, Denise de Castro 30 August 2005 (has links)
Cerebral angiography is radiological procedure to demonstrate areas of the vascular supply of the brain through the injection of a positive contrast where proper visualization of the blood stream is obtained. In this experiment, twenty adult dogs were submitted to a cerebral angiography. In the operation room, under general anesthesia, the left carotid artery was exposed and catheterized. The animals were then conducted to the Veterinary Radiological Sector for the cerebral angiography procedure. When good quality images where obtained, positive contrast was administrated and new x-rays were taken. The aim of this study was to evaluate this technique as a alternative radiographic technique in cases where alteration of the blood stream by occupying space such as may brain damages occure. The technique used was effective to obtain clear images, when determining the irrigation area of the brain. / A Angiografia Cerebral é um exame radiológico para demonstração da vascularização através da injeção de um meio de contraste positivo onde obtém-se adequada visualização do suprimento sangüíneo. Neste experimento vinte cães foram submetidos à Angiografia Cerebral, onde no bloco cirúrgico e sob anestesia geral, procedeu-se exposição e cateterização da artéria carótida comum esquerda. Os animais foram, então, conduzidos ao Setor de Radiologia Veterinária para realização do exame radiográfico simples e, após obtidas imagens satisfatórias, administrado o meio de contraste positivo, quando novas tomadas radiográficas foram realizadas. O objetivo foi avaliar a técnica como método complementar ao exame radiográfico simples, em casos de suspeita de alteração do fluxo sangüíneo, por lesões que ocupem espaço no cérebro, onde o primeiro não foi conclusivo. A técnica utilizada mostrou-se efetiva para a obtenção de imagens nítidas para determinação da área de irrigação sangüínea cerebral.
115

Efeitos renais da administração intravenosa de meios de contraste iodado em cães submetidos à tomografia computadorizada: aspectos ultrassonográficos e laboratoriais / Renal effects of intravenous administration of iodinated contrast media in dogs undergoing computed tomography: ultrasonographic and laboratory aspects

Claudia Matsunaga Martin 11 September 2015 (has links)
A nefropatia induzida por contraste (NIC) é uma nefropatia aguda, secundária à administração intravascular de meios de contraste iodado (MCI), cujas propriedades físico-químicas, especialmente a osmolaridade, relacionam-se ao seu desenvolvimento. Dentre os mecanismos fisiopatológicos desta enfermidade destacam-se a vasoconstrição intrarrenal prolongada, consequente redução da perfusão renal, hipóxia e isquemia medulares, associada ao dano tubular renal devido à citotoxicidade do contraste. Frente à existência de poucas informações relacionadas a estes mecanismos na literatura médico-veterinária e a grande demanda de exames de tomografia computadorizada que utilizam contrastes, objetivaram-se caracterizar e comparar os efeitos renais da administração intravenosa de MCI não iônicos de diferentes osmolaridades, em grupos de cães com fatores de risco para o desenvolvimento da NIC, por meio das avaliações ultrassonográficas modo B, Doppler colorido, de amplitude e pulsado, pareada aos exames laboratoriais, a fim de estimar indiretamente o potencial nefrotóxico de cada contraste. Este estudo também objetivou verificar a ocorrência da NIC. Constituíram-se dois grupos de acordo com o MCI utilizado: o grupo GIH (11 cães receberam iohexol [baixa osmolaridade]) e o grupo GID (sete cães receberam iodixanol [isosmolar]). Administrou-se a dose de 600 mgI/kg/IV em ambos. Avaliaram-se os seguintes aspectos renais antes da administração do MCI (momento basal) e após 1,5 horas, 24 horas e 48 horas: morfometria (comprimento e volume), morfologia, ecogenicidade cortical e perfusão renais e resistência vascular intrarrenal (índices hemodinâmicos de resistividade e pulsatilidade), realizou-se ainda exame de urina I e se mensuraram as razões gama-glutamil transferase:creatinina (GGT:C) e proteína:creatinina (RPC) urinárias e a concentração sérica de creatinina. Estipulou-se avaliar os aspectos sonográficos do rim esquerdo, desde que ambos os rins apresentassem características morfométricas, morfológicas, de ecogenicidade cortical e perfusão, semelhantes na abordagem inicial de cada paciente. Os grupos apresentaram comportamentos similares para comprimento, RPC, exame de urina I e creatinina sérica. Constataram-se aumentos significativos do índice de resistividade (IR) e da razão GGT:C urinária e evidências de aumento significativo do volume renal, 1,5 horas após a administração do contraste, somente no grupo que recebeu iohexol. Em relação ao índice de pulsatilidade, embora ambos os grupos tenham apresentado comportamentos não similares, não se detectaram diferenças significativas entre o momento basal e os demais. Concluiu-se que o IR foi capaz de monitorar a hemodinâmica intrarrenal e demonstrar, assim como a razão GGT:C urinária, maior potencial nefrotóxico do iohexol, quando comparado ao iodixanol. Dessa forma, considerou-se o iodixanol uma opção favorável para cães com fatores de risco para o desenvolvimento da NIC. Um cão de 14 anos de idade, portador de insuficiência cardíaca e disfunção renal preexistente, desenvolveu a forma subclínica da NIC, reconhecida pela elevação de 0,5 mg/dL na creatinina sérica basal, 24 horas após a administração intravenosa do iohexol. A redução da perfusão renal verificada 1,5 horas após a utilização do contraste pode ser preditiva de NIC. De modo semelhante ao observado no homem, idade avançada, insuficiência cardíaca e disfunção renal preexistente, principalmente quando associadas, constituem fatores de risco para o desenvolvimento da NIC em cães / Contrast-induced nephropathy (CIN) is a type of acute nephropathy, secondary to intravascular administration of iodinated contrast media (ICM). The physicochemical properties of ICM, particularly the osmolarity of the media, are related to the development of CIN. The most important mechanisms of this nephropathy are intrarenal prolonged vasoconstriction, medular hypoxia, and ischemia associated with renal tubular damage due to contrast cytotoxicity. Owing to the limited information available in veterinary literature regarding these mechanisms and increase in the number of contrast-enhanced computed tomography examinations performed, this study aims to characterize and compare the renal effects of intravenous administration of two nonionic ICM of different osmolarities in groups of dogs with risk factors for CIN development, by using a B-mode, color, power- and pulsed-wave Doppler ultrasonography, and other laboratory tests, in order to indirectly estimate the nephrotoxic potential of each contrast. This study also aims to investigate the occurrence of CIN. The following two groups were established according to the nonionic ICM used: the GIH group (11 dogs administered iohexol [low osmolarity]) and the GID group (seven dogs administered iodixanol [iso-osmolarity]). Both the groups were administered the same dose (600 mgI/kg/IV). The following renal aspects were evaluated before administration of ICM (baseline) and after 1.5 h, 24 h, and 48 h: renal morphometry (length and volume), renal morphology, cortical echogenicity, renal perfusion, and intrarenal vascular resistance (resistive and pulsatility indices); in addition, urinalysis was performed, and urinary gamma-glutamyl transferase:creatinine ratio (GGT:C), urinary protein:creatinine ratio (UPC), and serum creatinine were also measured. The sonographic aspects of the left kidney were evaluated, only if both kidneys presented similar morphometry, morphology, cortical echogenicity, and perfusion during the first assessment of each patient. Both groups showed similar characteristics with respect to the length, UPC ratio, urinalysis, and serum creatinine levels. Significant increases were observed in the resistive index (RI) and urinary GGT:C, and evidence of significant increase was observed in the renal volume only in the GIH group, 1.5 h after contrast administration. No similarity was observed with respect to the pulsatility index in both the groups; however, there were no significant differences between baseline and 1.5-, 24- and 48-h time points. In conclusion, RI can be used to monitor intrarenal hemodynamics, and along with the urinary GGT:C, revealed that iohexol had higher nephrotoxic potential than iodixanol. Thus, iodixanol was considered a favorable option for dogs with risk factors for CIN development. A 14-year-old dog with heart failure and pre-existing renal dysfunction developed subclinical CIN, due to an increase in the serum creatinine (0.5 mg/dL) 24 h after intravenous iohexol administration. The decrease in renal perfusion observed 1.5 h after ICM administration may be predictive of CIN. As observed in humans, advanced age, heart failure, and pre-existing renal dysfunction, especially various associated factors, should be considered as risk factors for the development of CIN in dogs
116

A ressonância magnética no estudo da desintegração de comprimidos marcados com açaí (Euterpe oleracea)

Souza, Luiz Gustavo Rubi de [UNESP] 29 October 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-29Bitstream added on 2014-06-13T20:29:22Z : No. of bitstreams: 1 souza_lgr_me_botib.pdf: 668467 bytes, checksum: 6af9a46606d8122e4df642943b2d5e06 (MD5) / Universidade Estadual Paulista (UNESP) / Avaliar formas farmacêuticas sólidas in vivo fornece um entendimento mais profundo quando um efeito sistêmico ou local é desejado. Geralmente, estes estudos são realizados por meio da cintilografia e técnicas biomagnéticas. A Ressonância Magnética (RM) vem sendo aplicada em tecnologia farmacêutica sendo que estes estudos são realizados com comprimidos marcados por partículas de óxido de ferro ou por gadolíneo em pó. Este estudo propõe a utilização da RM para monitorar o processo de desintegração in vitro e in vivo de comprimidos contendo açaí (Euterpe oleracea) como agente de contraste natural. O açaí é uma fruta presente em abundância na região norte do Brasil com a propriedade de atuar como agente de contraste oral em imagens obtidas por RM. Comprimidos obtidos com diferentes desintegrantes (croscarmelose sódica, crospovidona e mistura efervescente) foram marcados com açaí e revestidos com uma solução de polímero pH-independente. As formas farmacêuticas foram avaliadas in vitro e in vivo em um equipamento de RM de 0,5 T. Os resultados mostraram que o açaí é um forte agente de contraste e pode ser empregado em estudos farmacêuticos. Foi possível definir a imagem do comprimido e quantificar o processo de desintegração. Não foram encontradas diferenças (p>0,7) no tempo de desintegração avaliado in vitro nas medidas empregando-se comprimidos de crospovidona (14±1 min) e croscarmelose (15±1 min). No entanto, comparando-se com os comprimidos efervescentes (6±1 min), o tempo de desintegração foi significantemente diferente (p<0,01). Foi possível obter as imagens ponderadas em T1 dos comprimidos no estômago humano com qualidade razoável. O tempo de desintegração dos comprimidos in vivo foi 14±1 min. Este estudo mostrou que a RM é uma técnica capaz de monitorar o processo... / The performance of pharmaceutical dosage forms must be fully investigated in vivo to provide more reliable information when a local or systemic effect is desirable. Generally, in vivo investigation on the behavior of dosage forms has been made by using gammascintigraphy and biomagnetic techniques. Magnetic resonance (MR) methods have become established tools in the drug discovery and development process. Most of MR studies have been made with tablets labeled with iron oxide particles or dry gadolinium chelates (Gd- DOTA) powder. The aim of this study was to evaluate the disintegration process of tablets labeled with açai (Euterpe oleraceae) in vitro and in human stomach. Açai is a typical fruit from Amazonia, and has been recognized for its functional properties for use as oral contrast agent for MR. Tablets obtained from different disintegrants (croscarmellose sodium, crospovidone and an effervescent blend) were labeled with açai and were coated by using pHindependent polymer solution. The dosage forms have been evaluated in vitro and in vivo in a 0.5 T magnetic resonance system. The results showed that açai may be employed as a useful contrast agent which for pharmaceutical purposes. It was able to define the image of the tablets and to quantify the disintegration process. The disintegration time evaluated in vitro for tablets obtained from crospovidone (14±1 min) and croscarmellose (15±1 min) it was not significantly different (p>0.7). However, in comparison with tablets obtained with effervescent blend (6±1 min), the disintegration time was significantly different (p<0.01). It was possible to obtain images of the tablets in human stomach in T1 weighting with reasonable quality. The disintegration time of tablets made from croscarmellose sodium obtained from in vivo measurements was 14±1 min. This study showed that MR technique... (Complete abstract click electronic access below)
117

Elastografia acoustic radiation force impulse (ARFI), doppler e ultrassonografia contrastada do baço canino /

Maronezi, Marjury Cristina. January 2016 (has links)
Orientador: Marcus Antônio Rossi Feliciano / Coorientador: Wilter Ricardo Russiano Vicente / Coorientador: Júlio Carlos Canola / Banca: Leandro Zuccolotto Crivellenti / Banca: Eliandra Antônia Pires Buttler / Resumo: O baço é um órgão que desenvolve inúmeras funções importantes no organismo e é um dos principais locais para o desenvolvimento de tumores primários, metastáticos e afecções do sistema hematopoiético, por isso realizar uma avaliação apurada neste órgão é de suma importância, em Medicina veterinária, particularmente em cães devido à importância econômica, afetiva e de similaridade cientifica para o homem. Todavia, a maioria dos métodos utilizados para o diagnóstico conclusivo de enfermidades esplênicas são métodos invasivos, sendo que os nãos invasivos perdem em sensibilidade e especificidade, dificultando que se proceda a um correto diagnóstico. Sendo assim, este estudo prospectivo visou avaliar a aplicabilidade das novas técnicas ultrassonográficas para avaliação esplênica de caninos, utilizando a elastografia ARFI (qualitativa e quantitativa), Doppler e ultrassonografia por contraste com microbolhas, com o intuito de determinar valores ainda não descritos na veterinária, as quais forneçam subsídios suficientes para se obter um diagnóstico conclusivo sobre a condição esplênica, nesta espécie. Os resultados obtidos nos cães saudáveis, por meio da ultrassonografia modo B apresentaram-se normais, sendo que na elastografia qualitativa, as porções esplênicas avaliadas apresentaram-se não deformáveis, com parênquima homogêneo de cor cinza escuro (hard). Na elastografia quantitativa os valores médios da velocidade de cisalhamento foram de 2,32 m/s para a cabeça, 2,16 m/s para o corp... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The spleen is an organ develops much important functions in the body and the spleen is one of the main organs prone to the development of primary tumors, metastasis and a broad range of diseases of the hematopoietic system perform assessment of spleen is important. In veterinary medicine, principally in dogs because of economic importance, affective and scientific similarity to humans. However, the most of the methods used for conclusive diagnosis of splenic diseases are invasive methods, noninvasive lose in sensitivity and specificity difficulting proceed to a correct diagnosis. Thus, this study aimed to perform the ultrasound scan of dogs spleen using the elastographic (qualitative and quantitative) Doppler and contrast enhanced ultrasonography. Determining values not described in veterinary, which provide sufficient subsidies to get a conclusive diagnosis of the splenic condition in this species. The results in healthy dogs showed, all splenic segments visualized with the B-mode ultrasonography appeared normal. Different splenic segments examined with qualitative elastography were free of any detectable malformations and the images appeared as homogeneous dark areas. The mean shear velocity values were 2.32 m/s for head, 2.16 m/s for body and 2.25 m/s for tail of the spleen, and they did not vary between the different age groups (P>0.05). In dogs with ehrlichiosis in subclinical phase showed, by B-mode examination, observed splenomegaly with presence of rounded borders and... (Complete abstract click electronic access below) / Mestre
118

Validação da técnica de angiotomografia helicoidal cerebral em cães hígidos /

Rodriguez Hurtado, Diana Milena. January 2013 (has links)
Orientador: Maria Jaqueline Mamprim / Coorientador: Luiz Carlos Vulcano / Banca: Cibele Figueira Carvalho / Banca: Amalia Agut Giménez / Resumo: Desenvolveu-se a técnica de angiotomografia helicoidal como ferramenta para obter referências de normalidade do suprimento sanguíneo cerebral em cães sadios. O presente trabalho foi realizado em 17 animais, sendo 8 adultos jovens da raça pointer e 9 adultos sem raça definida; machos e fêmeas que apresentaram exames clínico- neurológicos e laboratoriais dentro da normalidade. Realizaram-se imagens simples e com meio de contraste iodado (MCI) não iônico injetado na veia cefálica esquerda, e foram feitas reconstruções multiplanares (MPR). Foi possível evidenciar a maioria das artérias que formam o circulo arterial cerebral, alem de algumas variações anatômicas como a presencia de uma artéria intercarotidea direita e esquerda em 3 cães dos 17 animais, e ausência do ramo direito da artéria cerebral rostral em outros 3 animais, demonstrando assim que a angiotomografia helicoidal é um exame seguro e rápido que pode ser aplicado na rotina tomográfica de cães para correta visualização do suprimento sanguíneo encefálico. Avaliou-se também o efeito do MCI não iônico a uma dose de 900 mg Iodo/kg, no rim utilizando-se ultrassonografia (US) e correlacionou-se com os valores de ureia e creatinina antes e após sua administração. Não foram visibilizadas alterações do parênquima renal em nenhum dos animais. Os valores de creatinina após a injeção do contraste permaneceram dentro da normalidade, porém os valores da ureia apresentaram aumento significativo, Assim, estudos ultrassonográficos correlacionados com exames de laboratório devem ser realizados em maior número de cães para determinar segurança e acurácia dos MCI não iônicos / Abstract: Developed the technique of helical angitomography as a tool to get references from normal blood supply of the brain in healthy dogs. The present study was performed in 17 animals, 8 young adults breed pointer and 9 adult mixed breed; males and females with clinical, neurological and laboratory normal exams. There were simple images and nonionic iodinated contrast media (ICM) IV, injected into the left cephalic vein; were made multiplanar reconstructions (MPR). It was possible to demonstrate the major arteries that make up the arterial polygon of Willis, in addition some anatomical variations as the presence of an artery intercarotid right and left in 3 of 17 animals, and absence of the right branch of the rostral cerebral artery in other 3 animals, demonstrating that the helical angitomography is a safe and fast examination that can be applied in dogs routine tomographic for correct visualization of the cerebral blood supply. We also evaluated the effect of nonionic MCI at a dose of 900 mg Iodine/kg, in the kidney through ultrasound (U.S.) and correlated with the values of urea and creatinine before and after administration. No changes were seen in any of the renal parenchyma. Creatinine values after MCI remained within the normal range, however the values of urea showed on increase significant statistically, therefore ultrasound studies should be conducted to correlated with laboratory testing on a larger number of dogs to determine safety and accuracy of MCI / Mestre
119

Efeito de radiocontrastes sobre determinados sistemas de transporte de membrana celular de eritrócitos humanos

Oliveira, Rubens Marona de January 2004 (has links)
Made available in DSpace on 2013-08-07T19:06:00Z (GMT). No. of bitstreams: 1 000321939-Texto+Completo-0.pdf: 629614 bytes, checksum: 3a028aa2639bbe16eabae0603dd5e3f1 (MD5) Previous issue date: 2004 / Loss of renal function is a recognized complication following the intravascular use of radiocontrast agents. The cell membrane transport systems are possible targets for radiocontrast toxicity. The aim of the present study was to examine the effects of diatrizoate sodium (DS), diatrizoate meglumine (DM), a diatrizoate compound (DC), and Hypaque-M 76® upon membrane transport functions, using the erythrocyte as model. Na+/K+ pump activity was determined, the number of Na+/K+ pumps was estimated, and the cell membrane transports of L-arginine and choline were evaluated in erythrocytes obtained from normal individuals and from patients undergoing cardiac catheterization. Potassium influx was 1. 50±0. 35, 1. 32±0. 37, 1. 28±0. 30, and 1. 01±0. 25 mmol/L cell/h in control, DS, DM and DC groups, respectively (P=0. 004; DC against control group). Exposure to Hypaque-M 76® during cardiac catheterization diminished the activity of Na+/K+ pump (1. 40±0. 36 vs. 1. 27±0. 40 mmol/L cell/h; P=0. 039). The number of Na+/K+ pumps in presence of DS was decreased (156±36 vs. 143±34 pumps/erythrocyte; P=0. 015). L-arginine and choline membrane transports were unchanged, except at very high extracellular radiocontrast concentrations. Results suggest that a selective effect on erythrocytes membrane transport function seems to partake of the cytotoxic picture accompanying radiocontrast-induced acute renal failure. / Perda de função renal é reconhecidamente uma das complicações secundárias ao uso intravascular de radiocontrastes. A membrana celular e os sistemas de transporte são possíveis alvos para a toxicidade destas substâncias. O objetivo do presente estudo foi examinar os efeitos de diatrizoato de sódio (DS), diatrizoato meglumina (DM), um composto de diatrizoatos (CD), e Hypaque- M 76® sobre sistemas específicos de transporte de membrana celular, usando o eritrócito como modelo. A atividade da bomba de Na+/K+ foi determinada, o número de bombas de Na+/K+ foi verificado, e o transporte celular de L-arginina e colina avaliado em eritrócitos obtidos de indivíduos saudáveis e de pacientes que sofreram cateterismo cardíaco. O influxo de potássio foi 1,50±0,35, 1,32±0,37, 1,28±0,30, e 1,01±0,25 mmol/L cel/h nos grupos controle, DS, DM e CD, respectivamente (P=0,004; CD versus grupo controle). Exposição ao radiocontraste composto Hypaque-M 76® durante cateterismo cardíaco diminuiu a atividade de bomba de Na+/K+ (1,40±0,36 vs. 1,27±0,40 mmol/L cel/h; P=0,039). O número de bombas de Na+/K+ ativas em presença de DS foi diminuído (156±36 vs. 143±34 bombas/eritrócito; P=0,015). O transporte de membrana de L-arginina e colina permaneceu inalterado, exceto em concentrações extracelulares de radiocontrastes muito altas. Estes resultados sugerem que efeitos seletivos sobre a função dos sistemas de transporte de membrana analisados parecem participar do quadro de citotoxicidade que acompanha a insuficiência renal aguda induzida pelos radiocontrastes.
120

Análise da penetrabilidade de duas substâncias irrigadoras: estudo em canais simulados / Analysis of penetration two irrigating solutions: a study in simulated canals

Marcus Vinicius Corvelo de Andrade 27 September 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do estudo foi verificar ex vivo a penetração de duas substâncias irrigantes hipoclorito de sódio 5% e Chlor-Xtra (Vista Dental Products, Racine, WI) através da adição de corante em canais simulados de dentes clarificados. Sessenta caninos inferiores unirradiculares humanos foram utilizados. As raízes foram seccionados em 16mm e instrumentadas com limas rotatórias do sistema Protaper até a F2 no comprimento de trabalho de 15mm. As amostras foram submetidas ao processo de clarificação para ficarem transparentes e durante o processo foram criados os canais simulados no terço apical. As raízes foram divididas aleatoriamente em três grupos ( NaOCl 5%, Chlor-Xtra e água) contendo 20 espécime por grupo. As amostras foram irrigadas com 1,5mL de solução contraste( tinta chinesa junto com a solução irrigante do respectivo grupo). E cada amostra foi fotografada e analisada. Os dados foram analisados estatisticamente pelos testes Kruskal-Wallis e Student-Neuman-Keuls. Não houve diferença estatística entre as substâncias irrigantes testadas (p>0,05). A partir da análise dos dados, foi possível concluir que apesar da presença de agentes surfactantes na solução irrigante de Chlor-Xtra não houve uma melhor penetrabilidade nos canais simulados em comparação ao hipoclorito de sódio(NaOCl). / The aim of this work was to asses ex vivo penetration of two irrigation substances sodium hypochlorite 5% and Chlor-Xtra (Vista Dental Products, Racine, WI) by the addition of dye in simulated canals from cleared teeth. Sixty single-rooted human mandibular canines were used. Roots length was standardized to 16 mm and root canal shaping was performed to a working length of 15 mm using Protaper Universal rotary files (Maillefer) up to F2 corresponding to a 25/.08 size/taper. The samples were cleared using clearing technique and and simulated canals were created in apical third at the time of process. Roots were randomly divided into three groups (5% NaOCl, Chlor-Xtra and water) containing 20 specimens per group. Samples were irrigated with 1.5 mL of contrast solution (Chinese ink and irrigating substance of the group). And each sample was photographed and analyzed. Data were statistically analyzed by Kruskal-Wallis and Student-Neuman-Keuls tests. No statistical difference between the tested irrigating solutions was found (p> 0.05). From the data analysis, we conclude that in despite of the presence of surfactants in the irrigating solution Chlor-Xtra did not result better penetration into simulated canals than sodium hypochlorite (NaOCl).

Page generated in 0.0554 seconds