• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 207
  • 176
  • 39
  • 16
  • 7
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 462
  • 462
  • 166
  • 122
  • 97
  • 94
  • 93
  • 80
  • 76
  • 54
  • 53
  • 53
  • 50
  • 44
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Efeito do laser de baixa intensidade na polpa e nos tecidos apicais e periapicais em dentes de macaco

Crisci, Fernando Simões [UNESP] 05 September 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-09-05Bitstream added on 2014-06-13T19:01:54Z : No. of bitstreams: 1 crisci_fs_dr_arafo.pdf: 2406575 bytes, checksum: 7ed8c4c8f95948faa1e0430e502e380a (MD5) / Universidade Estadual Paulista (UNESP) / O presente estudo avaliou o efeito do laser de baixa intensidade diodo semicondutor de arseneto de gálio e alumínio em exposições pulpares induzidas e nos tecidos apicais e periapicais após tratamento endodôntico em dentes de macacos. Nas exposições pulpares, foi avaliado efeito do laser infra-vermelho associado ao hidróxido de cálcio, variando o tempo de aplicação, onde utilizou-se quatro macacos, totalizando 24 dentes, distribuídos em quatro grupos experimentais: Grupo I: Laser 2,5 segundos (dentes incisivos), Grupo II: Laser 40 segundos (dentes incisivos), Grupo III: Laser 40 segundos (dentes prémolares) e Grupo IV: Controle sem Laser (dentes pré-molares), por um período de 55 dias. Quanto ao efeito do laser sobre a agressividade tecidual do cimento endodôntico óxido de zinco e eugenol (OZE), após tratamento endodôntico nos tecidos apicais e periapicais, foi comparando o laser vermelho com o infravermelho, utilizando quatro macacos, totalizando 24 dentes, distribuídos em três grupos experimentais: Grupo I (Laser Vermelho), Grupo II (laser Infra-Vermelho) e Grupo III (Controle: Sem Laser), por um período de 22 dias. Decorrido os períodos experimentais de cada estudo, os animais foram mortos, os dentes ou peças removidas e preparadas para análise histológica. De acordo com a proposta e as condições específicas deste trabalho, os resultados nos permitem concluir que nas exposições pulpares, a irradiação com laser infra-vermelho (40 segundos) diminuiu a reação inflamatória e induziu a organização tecidual, bem como na formação da barreira mineralizada, apresentando diferenças estatísticas significantes entre os grupos (p<0,05), tendo como melhor resultado a irradiação com laser infra-vermelho (40 segundos), já nos tecidos apicais e periapicais a irradiação... / The present study evaluated the effect of the laser of low intensity diode semiconductor of gallium aluminum arsenide in exposed pulp induced in apical and periapical tissues after endodontic treatment in teeth of monkeys. In the exposed pulp, the effect of the laser infra-red associated to the hydroxide of calcium was evaluated varying the time of application, being used 04 monkeys, totaling 24 teeth, distributed in four experimental groups: Group I: Laser 2,5 seconds (incisive teeth), Group II: Laser 40 seconds (incisive teeth), Group III: Laser 40 seconds (premolar teeth) and Group IV: Control without Laser (premolar teeth), for a period of 55 days. As for the effect of the laser on the tissue aggressiveness of the endodontic zinco oxide and eugenol (OZE) sealer, after endodontic treatment o in the apical and Periapical tissues, the red laser was compared with the laser infra-red, using 04 monkeys, totaling 24 teeth, distributed in 03 experimental groups: Group I (Red Laser), Group II (Infra-red laser) and Group III (it Controls: Without Laser), for a period of 22 days. After the experimental periods of each study, the animals were killed, the teeth or pieces were removed and prepared for histological analysis. In agreement with the proposal and the specific conditions of this study work, the results allow to conclude us that in exposed pulp infra-red laser irradiation (40 seconds.) reduced the inflammatory reaction and induced the tissue organization, as well as the mineralized barrier formation and in apical and periapical tissues infra-red laser irradiation stimulated the cells of the periodontal tissue inducing periapical repair.
342

Regeneração óssea alveolar utilizando osso liofilizado, matrigel e células-tronco mesenquimais em coelhos (Oryctolagus cuniculus)

Pignone, Víviam Nunes January 2011 (has links)
A regeneração óssea alveolar tem sido um dos principais alvos de estudo na odontologia, tanto humana como veterinária, principalmente na implantodontia e nas cirurgias periodontais e buco-maxilo-faciais. Em função disto, este trabalho foi realizado com o objetivo de avaliar a regeneração óssea alveolar, utilizando como enxerto osso liofilizado e células-tronco mesenquimais (MSCs), oriundas da polpa dentária de um doador macho para enxerto alogênico. Foram utilizados 57 coelhas, Nova Zelândia, sendo um coelho doador das MSCs, distribuídos em sete grupos: controle (G1), osso liofilizado (G2), Matrigel (G3), Matrigel e MSC (G4), osso liofilizado e Matrigel (G5), Osso liofilizado, Matrigel e MSC (G6) e somente MSC (G7). Após a exodontia do incisivo inferior esquerdo, o alvéolo recebia o implante de acordo com cada grupo e avaliados em sete dias. As amostras foram coletadas para análise microscópica, desmineralizadas e não desmineralizadas, PCR, além de terem sido submetidas à análise radiográfica, a qual também era realizada no pré e no pós-operatório imediato. Macroscopicamente, foi observado espessamento do ramo mandibular dos animais dos grupos que receberam Matrigel e aceleração do crescimento dos dentes incisivos remanescentes nos animais que receberam terapia celular. Na análise microscópica, constatou-se que, todos os grupos que receberam como enxerto o osso liofilizado, o tempo de regeneração foi menor, embora o grupo controle tenha apresentado melhor organização na regeneração óssea, sendo que o tratamento com Matrigel resultou ainda em uma reação inflamatória exacerbada, dado este confirmado também nas amostras não desmineralizadas. As radiografias periapicais também apontaram que os grupos que foram tratados com osso liofilizado apresentavam maior área de radiopacidade, sugerindo aceleração do processo de regeneração. Porém, o teste de PCR não detectou a presença do cromossomo Y do doador nas fêmeas receptoras das MSCs. Os resultados sugerem que o uso da terapia celular diminui o tempo de regeneração óssea alveolar e, quando aliada ao osso liofilizado, acelera este processo. Entretanto, decorridos sete dias da aplicação do Matrigel, houve aumento da espessura do ramo mandibular no alvéolo onde foi aplicado, necessitando maior tempo de avaliação para melhor elucidar seu uso clínico. / The alveolar bone regeneration has been a major focus of study in dentistry, both human and veterinary medicine, especially in implant and periodontal surgery and in the bucco-maxillo facial. Because of this, this study was to evaluate alveolar bone regeneration, using lyophilized bone and implant as mesenchymal stem cells (MSCs) derived from the dental pulp of a male donor for allogeneic graft. We used 57 female New Zealand rabbits, one rabbit MSCs from donor, divided into seven groups: control (G1), lyophilized bone (G2), Matrigel (G3), Matrigel and MSC (G4), lyophilized bone and Matrigel(G5), lyophilized bone, MSC and Matrigel (G6) and MSC only (G7). After extraction of the left lower incisor, the socket receiving the implant according to each group and evaluated in seven days. The samples were collected for microscopic analysis, demineralized and non-demineralized, PCR, and they have been subjected to X-ray analysis, which was also held in pre-and postoperatively. Grossly, there was thickening of the mandibular branch of animals that received and accelerate growth of the incisor teeth remaining in the Matrigel animals that received cell therapy. Under microscopic analysis, we found that all groups that received the bone graft as lyophilized, regeneration time was lower, although the control group had a better organization in bone regeneration, and treatment with still resulted in a Matrigel exaggerated inflammatory response, since this is also confirmed in samples not demineralized. The periapical radiographs also showed that the groups were treated with lyophilized bone had a greater area of radiopacity, suggesting acceleration of the regeneration process. However, the PCR test failed to detect the presence of Y chromosome in female recipients of the donor of MSCs. The results suggest that the use of cell therapy reduces the duration and alveolar bone regeneration when combined with lyophilized bone, accelerates this process. However, Matrigel, there was increased thickness after seven days of applying of the mandibular alveolus in which it was applied, requiring longer evaluation to elucidate its clinical use.
343

Análise bacteriológica de infecções pulpares em dentes decíduos. / Bacteriological analysis of pulp infection in deciduous teeth.

Antonio Scalco Fabris 16 May 2011 (has links)
Foram analisados dentes decíduos com cárie dental profunda de 110 crianças, sendo coletadas 103 amostras de polpa necrosada e 7 de fístulas gengivais. Morfotipos bacterianos foram visualizados pelas colorações de Gram e Brenn-Brown, e os DNA foram obtidos e usados na detecção bacteriana por PCR. A predominância de cocos Gram positivos (81,8%) e cocobacilos Gram negativos (49,1%) foram observadas. Em 88 amostras de polpas, microrganismos com maior ocorrência foram: Enterococcus spp. (50%), P. gingivalis (49%), F. nucleatum (25%) e P. nigrescens (11,4%). Foram detectados em fístulas: P. gingivalis (43%), Enterococcus spp. (28,6%), F. nucleatum (14,3%), P. nigrescens (14,3%), e D. pneumosintes (14,3%). Os nossos resultados permitem concluir que a microbiota envolvida nas infecções pulpares em dentes decíduos é similar em termos qualitativos àquela observada em dentes permanentes. Entretanto, a predominância de Enterococcus spp. e P. gingivalis deve ser levado em consideração pelos clínicos em casos necessários de tratamento endodôntico em crianças com dentição decídua. / In this study, deciduous teeth with deep caries from 110 children, with 103 pulp necrosis and 7 gingival fistula samples were evaluated. Bacterial morphotypes were visualized by Gram staining and Brown-Brenn. DNA were obtained and used in bacterial detection by using PCR. The predominance of Gram-positive cocci (81.8%) and Gram-negative coccobacilli (49.1%) were observed. In 88 pulp samples a high frequency of microrganisms were observed: Enterococcus spp. (50%), P. gingivalis (49%), F. nucleatum (25%) and P. nigrescens (11.4%). In fistulas were detected: P. gingivalis (43%), Enterococcus spp. (28.6%), F. nucleatum (14.3%), P. nigrescens (14.3%), and Dialister pneumosintes (14.3%). Our results, suggest that the involved microbiota in pulp infections of deciduous teeth are qualitatively similar than those permanent teeth. However, a predominance of Enterococcus spp. and P. gingivalis was observed, and it must be considered in the endodontic treatment in children with primary dentition.
344

Citotoxicidade e genotoxicidade de cimentos endodônticos

Bin, Claudia Villela [UNESP] 10 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-10Bitstream added on 2014-06-13T19:31:20Z : No. of bitstreams: 1 bin_cv_me_sjc.pdf: 1076251 bytes, checksum: a167eb57ce7c6168b48f17de4f6795bc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O MTA é um cimento amplamente utilizado na endodontia devido ao potencial indutor da mineralização, sendo empregado em procedimentos de proteção do complexo dentino/pulpar, retrobturação, perfurações radiculares e de furca e em dentes com rizogênese incompleta. Inicialmente esse material não foi preconizado como cimento obturador de canais radiculares. Entretanto, recentemente foi criado um cimento endodôntico resinoso contendo MTA (MTA Fillapex) com essa indicação, porém não há estudos sobre este novo material. Como o MTA é utilizado sobre os tecidos periodontal, ósseo e pulpar, é importante conhecer seus efeitos citotóxicos e genotóxicos, uma vez que, alguns cimentos endodônticos podem liberar componentes tóxicos, prejudicando o processo de regeneração e reparação dos tecidos no qual entram em contato. Assim, o objetivo deste trabalho foi avaliar a citotoxicidade e genotoxicidade do MTA obturador (Fillapex) comparando-o com o MTA reparador e com o AH Plus. Fibroblastos de hamster Chinês (V79) foram colocados em contato com diferentes diluições de meios de cultura previamente expostos a esses materiais. A citotoxicidade foi avaliada através do ensaio de MTT, em espectrofotômetro, para a verificação da taxa de viabilidade celular. A genotoxicidade foi avaliada pela formação de micronúcleos (MNT), para detecção de mutações cromossômicas. A taxa de sobrevivência celular e o número de micronúcleos antes e após a exposição aos cimentos foram estatisticamente analisados pelo teste de Kruskal-Wallis e teste de Dunn (p<0,05). Os resultados mostraram que o MTA reparador manteve a viabilidade celular acima de 50% em todas as diluições. Porém, tanto o MTA Fillapex quanto o AH Plus foram altamente citotóxicos e capazes de aumentar a formação de micronúcleos em 8 vezes em relação ao grupo controle na diluição 1:4, mostrando que são cimentos cito e genotóxicos / The MTA is a sealer widely used in endodontics and for be considered a material that inducing mineralization, can be used in procedures for protection of dentin/pulp complex, retrofilling root and furcal perforations and in teeth with incomplete root formation. Initially this material was not recommended as root canal sealer. However, recently a resin sealer based on MTA (MTA Fillapex) was created for this indication, but there are no studies on this new material. As the MTA is used on the periodontal tissues, bone and pulp, it is important to know the cytotoxic and genotoxic effects, as some sealers can release toxic components, impairing the process of regeneration and repair of tissues in which they come into contact. Thus, the purpose of this study was to evaluate the cytotoxicity and genotoxicity of MTA obturator (Fillapex) comparing it with the MTA repairer and AH Plus. Chinese hamster fibroblasts (V79) were placed in contact with different dilutions of culture media previously exposed to such materials. Cytotoxicity was evaluated by MTT assay in spectrophotometer to check the viability rate and cell survival. The genotoxicity was evaluated by micronucleus (MNT) to detect chromosomal mutations. The cell survival rate and number of micronuclei before and after exposure to the cement were statistically analyzed by Kruskal-Wallis and Dunn test (p<0.05). The results showed that MTA reparative remained cell viability above 50% in all dilutions. However, both the MTA Fillapex and AH Plus were highly cytotoxic
345

Clareamento com peróxido de hidrogênio a 35% ativado por diversas fontes de energia : análise térmica e microdureza do esmalte /

Kabbach, William. January 2008 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: João Carlos Gomes / Banca: Carlos Alberto de Souza Costa / Resumo: O objetivo do presente estudo foi avaliar in vitro a variação de temperatura e a microdureza Knoop superficial do esmalte durante o processo de clareamento dental com peróxido de hidrogênio a 35% sob irradiação da luz halógena com o comprimento de onda de 400 a 500nm (HL), luz emitida por diodo com comprimento de onda de 460 de 480 (LED) e laser de diodo (DL) de alta intensidade e comprimento de onda de 810nm, em dentes humanos extraídos. Inicialmente investigou-se a variação de temperatura superficial através da termografia de infravermelho e a temperatura do interior da câmara pulpar por meio de termopares em incisivos inferiores humanos, quando submetidos ao clareamento dental com peróxido de hidrogênio a 35% nas cores vermelha (HP) e verde (HPM) irradiados por: HL e LED. Quatro grupos (n=10) foram divididos de acordo com o gel clareador e a fonte de luz. Os resultados foram submetidos à análise de variância e teste de Tukey (p < 0,05). Os valores médios e desvios padrão do aumento de temperatura dentro da câmara pulpar com a HL foram de 4.4 ± 2.1 °C para HP, e 4.5 ± 1.2 °C para HPM; enquanto que nos grupos usando LED, foram 1.4 ± 0.3 °C para HP, e 1.5 ± 0.2 °C para HPM. Para todas as temperaturas superficiais a variação máxima dos grupos irradiados com HL foi 6.5 ± 1.5 °C para HP, e 7.5 ± 1.1 °C usando HPM; enquanto para os grupos usando LED, foram 2.8 ± 0.7 °C usando HP, e 3 ± 0.8 °C para HPM. Não houve diferença estatística entre o aumento da temperatura pulpar e superficial entre os grupos usando os diferentes géis (p < 0,05). As médias de temperatura foram significativamente maiores para os grupos usando HL quando comparados com aqueles irradiados com LED (p < 0,05). Ainda foi investigada a variação de temperatura superficial e assim determinado o tempo de demora para ser atingida a variação crítica de temperatura...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vitro study was to evaluate the variation of temperature and Knoop microhardness on enamel surface during the bleaching process whith 35% hydrogen peroxide under irradiation by halogen light whit the wavelength of 400 to 500nm (HL), LED whit the wavelength of 460 to 480nm and high intensity diode laser LED whit the wavelength of 810nm (LD) on extracted human teeth. Initially were investigated the variation of surface temperature (infrared thermography) and the temperature of the interior of the pulp chamber (thermocouples) in human mandibular incisors when subjected to dental bleaching with 35% hydrogen peroxide in the colors red (HP) and green(HPM) irradiated by: HL and LED. Four groups (n = 10) were divided according to the bleaching gel and light source. The results were submitted to the analysis of variance and Tukey test (p < 0.05). The mean values and standard deviations of the temperature increase inside the chamber pulp with HL were 4.4 ± 2.1 °C using HP and 4.5 ± 1.2 °C using HPM; while in LED groups, were 1.4 ± 0.3 °C to HP, and 1.5 ± 0.2 °C using HPM. For all surface temperatures, the maximum variation of the groups irradiated with HL was 6.5 ± 1.5 °C to HP and 7.5 ± 1.1 °C using HPM; while for the groups using LED, were 2.8° ± 0.7 °C using HP, and 3 ± 0.8 °C for HPM. There were no statistical difference between the increase of pulp and superficial temperature between groups using the various gels (p < 0.05). Mean temperatures were significantly higher for groups using HL compared with those irradiated with LED (p < 0.05). Was investigated the variation of surface temperature and thus given the time-delay to hit the critical variation of temperature (5.5 °C for the pulp chamber and 10 °C for periodontal). Forty-five human inferior incisors were divided into 3 groups and submitted to dental bleaching using...(Complete abstract, click electronic access below) / Mestre
346

Avaliação in vitro da fotopolimerização de bráquetes vestibulares e linguais com arco de plasma, led e luz halógena /

Magno, Amanda Fahning. January 2008 (has links)
Orientador: Lídia Parsekian Martins / Banca: Mirian Aiko Nakane Matsumoto / Banca: Dirceu Barnabé Raveli / Resumo: O objetivo dessa pesquisa foi avaliar in vitro a fotopolimerização de bráquetes vestibulares e linguais utilizando o arco de plasma, o diodo emissor de luz (LED) e a luz halógena convencional em tempos diferentes. Dois artigos científicos foram redigidos e utilizados para a avaliação dos propósitos apresentados. Na análise por vestibular, não houve diferenças entre o uso da luz arco de plasma por 6 segundos, do LED por 10 segundos e da luz halógena por 40 segundos. A luz arco de plasma por 3 segundos e o LED por 5 segundos demonstraram resistências ao cisalhamento iguais entre si e significantemente menores em relação às da luz halógena (p<0,001). Os resultados do índice de adesivo remanescente (IAR) mostraram que a interface de fratura dente/bráquete ocorreu com maior freqüência em todos os grupos, entretanto, os dados não puderam ser avaliados estatisticamente em função da distribuição dos escores. Na análise por lingual, as três fontes de luz mostraram-se diferentes entre si (p<0,001). A luz arco de plasma em 6 segundos obteve a menor média de resistência ao cisalhamento, seguida do LED em 10 segundos, que por sua vez apresentou menor média em relação à luz halógena em 40 segundos. O teste quiquadrado demonstrou não haver diferença significativa nos escores do IAR quando empregados os diferentes tipos de luz. Foi concluído, por vestibular, que a luz arco de plasma e o LED podem ser utilizados por tempos reduzidos em relação à luz halógena, sem perda de resistência ao cisalhamento, mas com limites para esta redução. Nos testes por lingual, a luz arco de plasma obteve resistências menores que o LED, o qual demonstrou resistências menores que a luz halógena, porém, estas diferenças não afetaram o padrão de descolagem. / Abstract: The objective of this in vitro study was to evaluate the variation of temperature and Knoop microhardness on enamel surface during the bleaching process whith 35% hydrogen peroxide under irradiation by halogen light whit the wavelength of 400 to 500nm (HL), LED whit the wavelength of 460 to 480nm and high intensity diode laser LED whit the wavelength of 810nm (LD) on extracted human teeth. Initially were investigated the variation of surface temperature (infrared thermography) and the temperature of the interior of the pulp chamber (thermocouples) in human mandibular incisors when subjected to dental bleaching with 35% hydrogen peroxide in the colors red (HP) and green(HPM) irradiated by: HL and LED. Four groups (n = 10) were divided according to the bleaching gel and light source. The results were submitted to the analysis of variance and Tukey test (p < 0.05). The mean values and standard deviations of the temperature increase inside the chamber pulp with HL were 4.4 ± 2.1 °C using HP and 4.5 ± 1.2 °C using HPM; while in LED groups, were 1.4 ± 0.3 °C to HP, and 1.5 ± 0.2 °C using HPM. For all surface temperatures, the maximum variation of the groups irradiated with HL was 6.5 ± 1.5 °C to HP and 7.5 ± 1.1 °C using HPM; while for the groups using LED, were 2.8° ± 0.7 °C using HP, and 3 ± 0.8 °C for HPM. There were no statistical difference between the increase of pulp and superficial temperature between groups using the various gels (p < 0.05). Mean temperatures were significantly higher for groups using HL compared with those irradiated with LED (p < 0.05). Was investigated the variation of surface temperature and thus given the time-delay to hit the critical variation of temperature (5.5 °C for the pulp chamber and 10 °C for periodontal). Forty-five human inferior incisors were divided into 3 groups and submitted to dental bleaching using HP and activated by HL,...(Complete abstract, click electronic access below) / Mestre
347

Penetração de peróxido de hidrogênio 38% no interior da câmara pulpar de dentes bovinos e humanos com ou sem restauração submetidos ao clareamento externo /

Camargo, Samira Esteves Afonso. January 2005 (has links)
Orientador: Márcia Carneiro Valera / Banca: Antonio Carlos Bombana / Banca: Claudio Antonio Talge Carvalho / Resumo: Acredita-se que a penetração de peróxido de hidrogênio através do esmalte e dentina pode causar danos à polpa. A proposta deste trabalho foi avaliar a quantidade de peróxido de hidrogênio no interior da câmara pulpar de dentes bovinos e humanos com ou sem restauração, após clareamento pela técnica de consultório. Os dentes foram seccionados 3mm à junção amelo-cementária e divididos em dois grupos: A (setenta terceiros molares humanos) e B (setenta incisivos laterais bovinos) que foram subdivididos em: A1 e B1 restaurados com resina composta (Esthetic-X, Dentsply), A2 e B2 com CIV (Vidrion-R, SSWhite), A3 e B3 com CIV modificado por resina (CIV-MR) (Vitremer, 3M); A4, A5, B4 e B5 não foram restaurados. No interior da câmara pulpar de todos os dentes foi colocado tampão acetato. Os subgrupos A1 a A4 e B1 a B4 foram expostos ao peróxido de hidrogênio 38% (Opalescence XtraBoost, Ultradent) por 40 min. Os subgrupos A5 e B5 permaneceram em água deionizada por 40 min. O tampão acetato foi transferido a um tubo de ensaio reagindo com corante violeta leucocristal e peroxidase. A densidade óptica da solução foi avaliada em espectrofotômetro, os valores de absorbância convertidos em microgramas de peróxido e submetidos aos testes de Dunnett, Kruskal-Wallis, ANOVA e Tukey (5%). Verificou-se maior penetração de peróxido nos dentes bovinos (0,79l0,61æg) e humanos (2,27l0,41æg) restaurados com CIV-MR. A penetração do agente clareador foi maior em dentes humanos para qualquer situação experimental. Concluiu-se que a penetração de peróxido depende do material restaurador e que dentes humanos são mais susceptíveis à penetração do agente clareador para o interior da câmara pulpar do que dentes bovinos. / Abstract: It is believe that externally applied bleachings agents could penetrate into the pulp chamber.This study was conducted to evaluate pulp chamber penetration of peroxide bleaching agent in human and bovine teeh, after office bleach technique. All the teeth were sectioned 3mm apical of the cemento-enamel junction and were divided into 2 groups: A (70 third human molars) and B (70 bovine lateral incisor) that were subdivided in: A1 and B1 restored using composite resin (Esthetic-X, Dentsply), A2 and B2 using glass ionomer cement (Vidrion-R, SSWhite), A3 and B3 using resin-modified glass ionomer cement (Vitremer, 3M); A4, A5, B4 and B5 were not restored. Acetate buffer was placed in the pulp chamber and the treatment agent was applied for 40 min as follow: A1 to A4 and B1 to B4 38% hydrogen peroxide exposure and A5 and B5 immersion into distilled water. The buffer solution was transferred to a glass tube where leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to ANOVA and Dunnett, Kruskal-Wallis, and Tukey tests (5%). A higher level of hydrogen peroxide penetrated into the pulp chamber in resin-modified glass ionomer cements groups, bovine (0,79l0,61æg) and human (2,27l0,41æg). The bleaching agent penetration was higher in human teeth for any experimental situation. The penetration of the hydrogen peroxide depend on restorative materials and that human teeth are more susceptible to penetration of bleaching agent into the pulp chamber than bovine teeth. / Mestre
348

Reação histológica de exposições pulpares em dentes de ratos à aplicação do laser de baixa intensidade somente ou em associação ao capeamento com hidróxido de cálcio /

Crisci, Fernando Simões. January 2002 (has links)
Resumo: O presente estudo avaliou a reação histológica do efeito do laser de baixa intensidade diodo semicondutor de arseneto de gálio e alumínio (GaA1As, com comprimento de onda de 785 nm, infravermelho, com potência de emissão de 50 mW, densidade de energia de 3 J/cm2, em emissão contínua, por meio de ponta especial de fibra óptica, por um período de 2 segundos) em exposições pulpares induzidas em dentes de ratos. Foram utilizados 60 ratos, dos quais cada animal ofereceu dois dentes (totalizando 120), que foram distribuídos em 5 grupos experimentais: grupo I (controle), exposição capeada com hidróxido de cálcio; grupo II, laser imediato + hidróxido de cálcio; grupo III, laser imediato + hidróxido de cálcio + laser após 24 horas; grupo IV, laser imediato + hidróxido de cálcio + laser após 24 e 48 horas; e grupo V, somente a aplicação do laser. Decorridos os períodos experimentais de sete e 30 dias, os animais foram mortos, as peças removidas e preparadas para análise histológica. De acordo com a proposta e as condições específicas deste trabalho, os resultados nos permitem concluir que as associações laser imediato + hidróxido de cálcio e laser imediato + hidróxido de cálcio + laser 24 horas, foram os grupos que apresentaram os melhores resultados tanto aos sete dias (efeito antiinflamatório), quanto aos trinta dias (efeito no reparo tecidual). / Abstract: The present study evaluated the histological reaction of the low poweer laser effect, diode laser semiconductor of gallium aluminum arsenide (GaA1As, with wavelenght of 785 nm, infra-red, potency of emission of 50 mW, energy density of 3 J/cm2, with continuous emission, through special tip of optic fiber, for a period of two seconds) in exposed pulp induced in teeth of mice. Sixty mice were used, of which each animal offered two teeth (totaling 120), that were distributed in 5 experimental groups: group I(control group) exposed capping with calcium hydroxide; group II, immediate laser + calcium hydroxide; group III, immediate laser + calcium hydroxide + laser after 24 hours; group IV, immediate laser + calcium hydroxide + laser after 24 and 48 hours; and group V, only laser application. After the experimental periods of seven and thirty days, the animals were killed, the pieces were removed and prepared for histological analysis. In agreement with the proposal and the specific conditions of this study, the results allow us conclude that the associations of immediate laser + calcium hydroxide and immediate laser + calcium hydroxide + laser after 24 hours, were the groups that presented the best results in the periods of seven days (anti-inflammatory effect), and thirty days (effect in the tissue repair). / Orientador: Fábio Luiz Camargo Villela Berbert / Coorientador: Lizeti Toledo de Oliveira Ramalho / Banca: Renato de Toledo Leonardo / Banca: Jesus Djalma Pécora / Mestre
349

Abordagem metagenômica de procariotos e presença de genes de resistência a agente antimicrobianos em saliva, biofilme supragengival e canais radiculares com infecções agudas

Moraes, Ludmila Coutinho January 2016 (has links)
O objetivo do presente estudo clínico foi compreender o efeito do uso prévio de agentes antimicrobianos na diversidade e a estrutura do microbioma procariótico de saliva, biofilme supragengival e canal radicular de dentes com infecção endodôntica aguda. Realizaram-se coletas microbiológicas de saliva (S), biofilme supragengival (BS) e canal radicular (CR) de pacientes que não utilizaram antibióticos (G1: n=6) e de pacientes que utilizaram antibióticos (G2: n=6). Para a caracterização das comunidades de procariotos por meio de sequenciamento de alto rendimento, foram produzidos pools de seis amostras para cada um dos sítios. A região hipervariável V3-V4 do gene 16S rRNA foi amplificada e a plataforma Illumina MiSeq foi empregada para análise das sequências geradas. Foram determinadas a presença e abundância relativa das unidades taxonômicas operacionais (OTUs) em cada amostra. Procedeu-se a análise de alfa-diversidade para cada amostra, considerando-se as métricas de Simpson, dominância, estimativa de riqueza de Chao-I e o Índice de Shannon. Os valores obtidos foram comparados por meio de testes estatísticos. Para a análise dos índices de beta-diversidade, empregou-se o método de agrupamento UPGMA, com jackknifing e método de comparação UniFrac com peso. A representação gráfica tridimensional da beta-diversidade foi realizada por meio de análise de coordenadas principais. A técnica de PCR gene específico foi empregada para determinar a presença de genes relacionados à resistência bacteriana para agentes beta-lactâmicos (blaTEM, blaZ, ampC, mecA), macrolídeos (ermB, ermC, mefA), tetraciclinas (tetM, tetQ, tetW), lincosamidas (lnuB, lsaB) e vancomicina (vanA, vanD, vanE). A similaridade para a presença/ausência de genes de resistência nas amostras de S, BS e CR em G1 e G2 foi determinada por meio de coeficiente de agrupamento, utilizando-se o método UPGMA com distância Euclidiana. Todos os pacientes apresentavam infecção endodôntica aguda, caracterizada pela presença de dor espontânea, necrose pulpar e dor à percussão vertical. Aumento de volume foi observado em 8/12 pacientes. Os pacientes do Grupo 2 utilizaram beta-lactâmicos previamente à consulta (amoxicilina = 5; cefalexina = 1). Há predomínio de integrantes do domínio Bactéria em todas S, BS e CR. Archaea pertencentes ao gênero Methanobrevibacter foram encontradas apenas em amostras de CR, constituindo menos de 1% do total de OTUs (G1-CR = 0,319%; G2-CR = 0,014%). Há predomínio de bactérias dos filos Firmicutes e Bacteroidetes em amostras de S, BS e CR. Há redução intensa no percentual de OTUs pertencentes ao Filo Firmicutes em amostras de saliva, quando antibiótico foi utilizado (G1-S = 75,371; G2-S = 35,242). Comportamento oposto ocorreu neste ecossistema para integrantes do Filo Bacteroidetes (G1-S = 12,657; G2-S = 33,947). Tanto em G1 quanto em G2, bactérias do gênero Streptococcus predominam em amostras de S e BS. Em canais radiculares, maiores percentuais de OTUs foram observados para os gêneros Porphyromonas e Prevotella. As métricas de alfadiversidade indicam que o uso prévio de antimicrobiano parece oportunizar o estabelecimento de espécies antes menos abundantes, especialmente em saliva (dominância: G1-S>G2-S; índice de Shanon: G1-S<G2-S; índice de Simpson: G1- S<G2-S; índice de Chao-1: G1-S<G2-S). A análise de beta-diversidade mostra proximidade entre G1-BS e G2-BS; há distanciamento entre G1-S e G2-S. As amostras G1-CR e G2-CR estão mais distantes de S e BS, sugerindo maior seleção imposta pelo ecossistema do CR aos procariotos. Os genes de resistência mais frequentemente detectados foram tetM, tetQ, tetM, ermB e mefA. Não foram detectados genes vanA, vanD, vanE, blaZ, mecA, lnuB e ermC. O gene ermB foi frequentemente detectado em amostras de S, BS e CR em ambos os grupos. Em pacientes que não utilizaram antibiótico, o gene tetM e o gene tetQ foram detectados simultaneamente em S, BS e CR (tetM = 4/6; tetQ = 3/6). A análise multivariada não demonstrou nível de agrupamento alto entre amostras de um mesmo paciente, de um mesmo ecossistema, ou de um mesmo grupo. A partir dos resultados do presente estudo, observou-se que a utilização de agente antimicrobiano betalactâmico parece alterar parâmetros composicionais de comunidades de procariotos na cavidade bucal. Entretanto, particularidades relativas a cada ecossistema podem modular a extensão deste efeito, parecendo ser mais intensos em amostras de S do que em BS e CR. / The present clinical study aimed to assess the effect of antibiotics over the diversity and structure in prokaryotic communities of saliva, supragengival biofilm and root canal of teeth with acute primary infections. Samples of saliva (S), supragengival biofilm (BS) and root canal of teeth with acute primary infections (CR) were collected from patients, and were grouped according with the previous use of antibiotic (G1 = no antibiotics; G2 = antibiotics). Pooled samples for each community were evaluated. DNA sequencing was performed with MiSeq (Illumina). The V3-V4 hypervariable region from the 16S rRNA gene was amplified. The presence and relative abundance of the operational taxonomic units (OTUs) was determined for each sample. Alpha-diversity analysis was performed with the Simpson’s index, dominance, Chao-1 richness index and Shannon’s index. Statistical analysis was carried out to compare their values for each community.Beta-diversity was computed through UPGMA clustering and jackknifing. The principal coordinate analysis employed weighted UniFrac. Gene-specific PCR was employed to detect resistance genes to lactamics (blaTEM, blaZ, ampC, mecA), macrolides (ermB, ermC, mefA), tetracyclines (tetM, tetQ, tetW), lincosamides (lnuB, lsaB) e vancomycin (vanA, vanD, vanE). The UPGA clustering analysis with Euclidean distance was applied to investigate the existence of similar groups of samples. A dendrogram was constructed to show the arrangement of the sample groups produced by clustering. All the patients had primary acute endodontic infections, with spontaneous pain, pulp necrosis and tenderness on percussion. Swelling was observed for 8 out of 12 patients. Patients from G2 had lactamics before the urgency appointment (amoxicillin = 5; cephalexin = 1). Bacteria were predominant in S, BS and CR samples. Archaea belonging to the genus Methanobrevibacter were only detected in RC samples and comprised less than 1% of all the OTUs G1-CR = 0.319%; G2-CR = 0.014%). The great majority of the detected OTUs in S, BS, and CR belonged to the phyla Firmicutes and Bacteroidetes. Reduction in the percentage of Firmicutes was observed in G2-S (G1-S = 75.371%; G2-S = 35.242%). A distinct behavior was demonstrated by the Bacteroidetes (G1- S = 12.657%; G2-S = 33.947%). Components belonging to the genus Streptococcus were predominant in S and BS, for both G1 and G2. CR harbored high percentage of species belonging to the genus Porphyromonas and Prevotella. The alpha-diversity indexes demonstrated that the G2-S had an increase in low abundant species (dominance: G1- S>G2-S; Shanon index: G1-S<G2-S; Simpson index: G1-S<G2-S; Chao-1 index: G1-S<G2- S). Beta-diversity showed that G1-BS and G2-BS had close spatial distribution. G1-CR and G2-CR were more distant from S and BS samples. The RC may promote a most intense species selection, due to environmental conditions. The most frequently detected genes associated with resistance to antibiotics were tetM, tetQ, tetM, ermB, and mefA. The genes vanA, vanD, vanE, blaZ, mecA, lnuB, and ermC were not detected in the samples. The gene ermB was frequently detected in S, BS and CR samples. In patients from G1, tetM and tetQ were detected simultaneously in all the three environments (tetM = 4/6; tetQ = 3/6). There was no clustering behavior for samples belonging to different environments in the same patients and between the same environment samples from different groups. An overall analysis from the data allows for suggesting that the use of lactamic agents may alter compositional parameters from prokaryotic communities in the oral cavity to different extents. Specific environmental characteristics from each site may modulate the effect that seemed to be more intense for S than for BS and CR.
350

Desenvolvimento de biomateriais eletrofiados, biorreatores e modelos fenomenológicos para a engenharia de tecidos

Paim, Ágata January 2017 (has links)
Uma potencial alternativa para o transplante de tecidos é a engenharia de tecidos. Células-tronco mesenquimais e scaffolds eletrofiados são comumente utilizados nesta área devido à capacidade multipotente de diferenciação destas células e à rede de poros interconectados destas estruturas fibrosas. Além disso, bioreatores de perfusão podem ser utilizados para melhorar o transporte de nutrientes e reduzir o acúmulo de metabolitos tóxicos. Neste contexto, uma maneira de estudar e otimizar o sistema de cultivo é utilizar técnicas de modelagem para descrever interações ou processos individuais envolvidos no crescimento celular. Deste modo, o objetivo geral deste estudo é realizar o cultivo de células-tronco mesenquimais da polpa de dente decíduo (DPSCs) utilizando scaffolds tridimensionais eletrofiados de policaprolactona (PCL), biorreatores e técnicas de modelagem. Inicialmente foram testadas diferentes misturas de solventes (clorofórmio e metanol), a fim de produzir scaffolds com poros adequados ao cultivo tridimensional. Os diâmetros de fibra e de poro foram determinados por microscopia eletrônica de varredura (MEV). O crescimento e o metabolismo das células foram avaliados através da determinação da atividade metabólica e das concentrações de glicose e lactato do meio de cultivo, e a infiltração celular foi observada com a marcação do núcleo celular. Depois de estabelecidos os parâmetros de eletrofiação, o efeito da perfusão direta no desprendimento de DPSCs de scaffolds eletrofiados de PCL foi estudado. A atividade metabólica das células foi determinada para diferentes tempos de adesão, vazões e densidades de semeadura, e a tensão de cisalhamento na parede do poro foi calculada para cada vazão. A morfologia das células foi avaliada através de imagens de microscopia confocal e MEV. Paralelamente, foram realizadas simulações utilizando o software OpenFOAM para estudar como os parâmetros e variáveis de entrada (concentração inicial de glicose, porosidade e espessura do scaffold) afetam as saídas (fração volumétrica de células e concentração de substrato) de um modelo de proliferação celular que considera a difusão e o consumo de glicose. As contribuições do teor de oxigêno na cinética de crescimento de Contois e da variação da porosidade com o tempo devido à degradação do polímero também foram avaliadas. Inicialmente, foi observado que apenas um tamanho de poro maior que o diâmetro da célula permitiu a infiltração das células no scaffold. Então, observou-se que o aumento do tempo de adesão acarretou em maior espalhamento das células e, assim como a diminuição da densidade de semeadura e da tensão de cisalhamento, resultou em uma redução do desprendimento das células sob perfusão. Quanto ao modelo fenomenológico, observou-se maior sensibilidade à concentração inicial de glicose e à porosidade do scaffold, e aos parâmetros adimensionais relacionados à proliferação e morte celular e ao consumo de nutrientes. Além disso, o número inicial de células apresentou maior impacto no transporte de massa do que no crescimento celular. Neste estudo, foi possível obter scaffolds eletrofiados e conduções de cultivo dinâmico adequadas ao cultivo tridimensional de DPSCs, e elucidar os efeitos da limitação do transporte de massa e do oxigênio no crescimento celular, e da degradação do polímero no transporte de massa. / A potential alternative to tissue transplant is tissue engineering. Mesenchymal stem cells and electrospun scaffolds are commonly used in this field due to the multipotent differentiation capacity of these cells and the interconnected pore network of these fibrous structures. In addition, perfusion bioreactors can be used to enhance nutrient transport and reduce the accumulation of toxic metabolites. In this context, one way to study and optimize the culture system is to use modeling techniques to describe interactions or individual processes involved in cell growth. Thus, the objective of this study is to perform the three-dimensional culture of mesenchymal stem cells of dental pulp (DPSCs) using electrospun polycaprolactone (PCL) scaffolds, bioreactors and modeling techniques. Initially, different solvent mixtures (chloroform and methanol) were tested to produce scaffolds with pores suitable to three-dimensional culture. Fiber and pore diameter was determined using a scanning electron microscope. Cell growth and metabolism were evaluated through the metabolic activity and the culture medium concentration of glucose and lactate, and the cell infiltration was observed with cell nuclei staining. After the establishment of the elesctrospinning parameters, the effect of direct perfusion on DPSCs detachment from PCL electrospun scaffolds was investigated. The metabolic activity of the cells was determined for different adhesion times, flow rates and seeding densities and the pore wall shear stress was calculated for each flow rate. The cell morphology was evaluated through scanning electron and confocal microscopy imaging. In parallel, simulations with the software OpenFOAM were performed to study how parameters and inputs (initial glucose concentration, porosity and thickness of the scaffold) affect the outputs (cell volume fraction and substrate concentration) of a model of cell proliferation and glucose diffusion and consumption. The contribution of the oxygen in the Contois growth kinetics and the porosity variation with time due to polymer degradation was also evaluated. Initially, it was observed that only a pore size higher than the cell diameter allowed the infiltration of the cells through the scaffold. Then, it was observed that a higher adhesion time leaded to higher cell spreading in static conditions and, similar to smaller seeding densities and shear stresses, reduced cell detachment under perfusion. Regarding the phenomenological model, it was observed that the model is more responsive to the initial glucose concentration and scaffold porosity, and to the dimensionless parameters related to cell proliferation, death and nutrient uptake. Furthermore, the initial cell number had a more significant impact on mass transport than on cell growth. In this study, it was possible to obtain an electrospun scaffold and dynamic culture conditions suitable for the three-dimensional culture of DPSCs, and to elucidate the effects of transport limitations and of oxygen on cell growth, and of polymer degradation on mass transport were elucidated.

Page generated in 0.0899 seconds