• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 338
  • 7
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 351
  • 320
  • 216
  • 168
  • 168
  • 140
  • 97
  • 84
  • 75
  • 72
  • 61
  • 60
  • 60
  • 58
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo das propriedades mecânicas da interface adesiva criada por sistemas adesivos convencional e autocondicionante, associados ou não ao laser Nd:YAG, utilizando a técnica da nanoindentação /

Silva, Patricia Rondon Pleffken da. January 2010 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Banca: Alessandra Bühler Borges / Banca: Andrea Anido Anido / Resumo: O objetivo desta pesquisa foi avaliar a influência do laser Nd:YAG nas propriedades mecânicas (dureza e módulo de elasticidade) da interface adesiva, utilizando a técnica da nanoindentação, empregando-se sistema adesivo convencional Adper Single Bond 2 - 3M ESPE (SB) ou autocondicionante Clearfil SE Bond - Kuraray (CSE). Doze terceiros molares humanos tiveram suas superfícies oclusais desgastadas até a exposição da dentina superficial. Uma cavidade circular padronizada com fresa 3053 foi realizada na superfície oclusal proporcionando 2 mm de dentina remanescente. Os espécimes foram embutidos em resina acrílica, e seccionados no sentido mésio-distal, sendo as 24 hemi-coroas obtidas divididas em quatro grupos: Grupo controle (SBC) - aplicação do sistema SB de acordo com as recomendações do fabricante; Grupo laser (SBL) - aplicação do sistema adesivo SB e tratamento com laser Nd:YAG (140mJ/cm2/60s/não contato); Grupo controle (CSEC) - aplicação do sistema adesivo autocondicionante CSE de acordo com as recomendações do fabricante; Grupo laser (CSEL)- aplicação do sistema adesivo autocondicionante CSE e tratamento com laser Nd:YAG (140mJ/cm2/60s/não contato). Após a polimerização dos sistemas adesivos, foram aplicados dois incrementos da resina composta Filtek Z 350 (3M ESPE). Os corpos-de-prova foram imersos em água destilada e armazenados por 24h em estufa 37ºC e submetidos à nanoidentação em aparelho Nano Indenter® XP (MTS®, MN, EUA).. Os resultados foram submetidos aos testes estatísticos de Análise de Variância (ANOVA), Tukey e t-Student (p<0,05). Concluiu-se que a aplicação do laser Nd:YAG em ambos os sistemas adesivos não alterou o nível de dureza da interface adesiva, no entanto alterou o módulo de elasticidade / Abstract: The aim of this study was to evaluate the influence of Nd: YAG laser on the mechanical properties (hardness and modulus of elasticity) of the adhesive interface, using the technique of nanoindentation, employing conventional adhesive system Single Bond 2 3M ESPE (SB) or selfetching adhesive system Clearfil SE Bond - Kuraray (CSE). On 12 human molars, a flat superficial dentin surface was exposed by abrasion. A standardized circular cavity with bur 3053 was performed on the occlusal surface and dentin thickness was standardized in 2 mm. The specimens were embedded in resin acrylic and sectioned mesio-distally through their long axes, and the 24 hemi-crowns obtained divided into four groups: Control Group (SBC) - the application of SB system according to the manufacturer's recommendations; Laser Group (SBL) - SB adhesive system and treatment with Nd: YAG laser (140mJ/cm2/60s/no contact) Control Group (CSEC) - application of CSE self-etching adhesive system according to the manufacturer's recommendations; Laser Group (CSEL) - application of CSE self-etching adhesive system and treatment with Nd: YAG laser (140mJ/cm2/60s/no contact). After polymerization of the adhesives, were applied two increments of composite resin Filtek Supreme and specimens were immersed in distilled water and stored for 24 hours at 37 ºC and submitted to nanoidentation in Nano Indenter ® XP (MTS ®, MN, USA. Nanoindentation were made on composite resin, adhesive system, hybrid layer and dentin. The results were analyzed by a tree-way ANOVA, Tukey and e t-Students (p<0,05). It was concluded that the application of Nd:YAG laser in both adhesive systems did not change hardness level of hybrid layer, however chanded the elastic modulus / Mestre
52

Avaliação imediata e após 6 meses da resistência de união a dentina de restaurações de resina composta classe I in vivo e in vitro

Rêgo, Heleine Maria Chagas [UNESP] 23 June 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-23. Added 1 bitstream(s) on 2016-06-07T17:17:18Z : No. of bitstreams: 1 000865416.pdf: 2581195 bytes, checksum: baec4e58131e8a8b1372e9f152ca300b (MD5) / Este estudo avaliou a resistência de união a dentina de restaurações de resina composta de forma imediata (24 horas) e em longo prazo (6 meses), submetidos a diferentes protocolos de envelhecimento. Cem dentes posteriores humanos foram divididos em cinco grupos (n = 20) de acordo protocolo de envelhecimento que receberam e posteriormente subdivididos em dois subgrupos (n = 10) de acordo com o tempo de armazenamento, totalizando dez subgrupos: In vivo (permaneceu em atividade bucal por 24 horas ou 6 meses); Estufa (armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem (submetidos a 27/666 ou 5000/120000 ciclos termomecânicos); Estufa com Pressão Pulpar Simulada (PPS) (restauração realizada sob PPS e em seguida armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem com PPS (restauração realizada sob PPS e em seguida submetidos a 27/666 -24 horas- ou 5000/120000 -6 meses- ciclos termomecânicos). Após a abertura da cavidade, a restauração foi realizada com a aplicação de ácido fosfórico a 37% (Vigodent), sistema adesivo Adper Single Bond 2 (3M ESPE) e resina composta Grandio (Voco), seguindo a orientação dos fabricantes. Após os diferentes tratamentos os espécimes foram seccionados obtendo-se palitos que foram submetidos ao teste de microtração. Os valores obtidos foram submetidos ao teste ANOVA dois fatores (protocolo de envelhecimento e tempo de armazenamento) e em seguida ao Teste de Tukey (5%). Os resultados para os testes de microtração foram (em MPa ±dp): Grupo estufa 24 h, 24,96±0,95A; Grupo ciclagem 24 horas, 23,96 ± 0,56AB; Grupo in vivo 24 horas, 23,21 ± 1,23AB; Grupo ciclagem com PPS 24 horas, 19,49 ± 1,51BC, Grupo ciclagem 6 meses, 18,16 ± 0,80CD; Grupo ciclagem com PPS 6 meses, 17,88 ± 1,25CD; Grupo estufa com PPS 24 horas, 17,65 ± 0,45CD; Grupo estufa 6 meses, 16,68 ± 1,30CD; Grupo estufa com PPS 6 meses, 14,33 ± 1,48D; Grupo in vivo 6 meses,.... / This study evaluated the bond strength of composite resin restorations submitted to different storage aging protocols, immediately and long-term (6 months). One hundred human posterior teeth were divided into five groups (n = 20) according storage aging protocol: Group, Group in vivo, Group water, Group cycling, Group water with Simulated Pulpal Pressure (PPS) and Group cycling with Simulated Pulpal Pressure. As further subdivided into two subgroups (n = 10) according to the time of storage were performed: 24 hours (24 hours in vivo 24 hours in water, 27/666 thermal and mechanical cycles) 6 months (6 months in vivo, 6 months in water and 5000/120000 thermal and mechanical cycles). After the opening of the cavity, the restoration was carried out with the use of phosphoric acid 37% (Vigodent), Single Bond 2 adhesive system (3M ESPE) and composite resin Grandio (Voco), following the lead of the manufacturers. After being held aging protocols for the storage time subgroup belonging specimens were sectioned obtaining sticks were submitted to microtensile test. Data were submitted to ANOVA two factors (aging and storage time) and then Tukey test (5%). The results for the microtensile tests were (MPa) ± SD: Group water 24 hours, 24.96 ± 0.95A; Group cycling 24 hours, 23.96 ± 0.56AB; Group in vivo 24h, 23.21 ± 1.23AB; Group cycling with PPS 24 hours, 19.49 ± 1.51BC, group cycling six months, 18.16 ± 0.80CD; Group cycling with PPS 6 months, 17.88 ± 1.25CD; Group water with PPS 24 hours, 17.65 ± 0.45CD; Group water 6 months, 16.68 ± 1.30CD; Group water with PPS 6 months, 14.33 ± 1,48D; In vivo group 6 months, 14.16 ± 1,51D. It was concluded that the different aging protocols used as storage times influence the bond strength dentin-resin
53

Influência de uma substância antioxidante na união de materiais resinosos à dentina após a realização de clareamento /

Toseto, Roberta Mariano. January 2010 (has links)
Orientador: André Luiz Fraga Briso / Banca: Paulo Henrique dos Santos / Banca: Mirela Sanae Shinohara / Resumo: Este estudo analisou a influência do ascorbato de sódio 10% (AS) na formação de tags e camada híbrida em dentina após clareamento dental. Materiais e métodos: Foram testados 6 grupos. GI- Controle: somente restaurações de Resina Composta (RC); GII- Ascorbato de Sódio (AS) + RC; GIII- clareamento com peróxido de carbamida 10% (PC) + RC; GIV- PC + AS + RC; GV- clareamento com peróxido de hidrogênio 35% (PH) + RC; GVI- PH + AS + RC. Após os tratamentos, os dentes foram seccionados e descalcificados. Os cortes foram montados em lâminas de vidro e corados pelo método Brown & Brenn. A análise em microscopia óptica comum (Axiophot) em 400X, evidenciou os tags e camada híbrida formados. Resultados: Os dados foram tabulados, sendo obtidas as respectivas médias para comprimento dos tags e a espessura da camada híbrida: GI- 10 e 3.1μm, GII- 9.2 e 2.4 μm, GIII- 5.4 e 1.5 μm, GIV- 6.8 e 2.1 μm, GV- 5.7 e 1.6 μm, GVI- 7.1 e 2.1 μm. Conclusão: O clareamento dental com PC ou PH prejudica a formação de tags resinosos e camada híbrida. O uso do AS aumentou o comprimento destas estruturas / Abstract: This study analyzed the influence of 10% sodium ascorbate (SA) on tag and hybrid layer formation in dentin after bleaching. Materials and Methods: Six groups were tested: GI- Control: restoration; GII- Sodium Ascorbate (SA) + restoration; GIII- Bleaching with carbamide peroxide (CP) + restoration; GIV- bleaching with CP + SA+ restoration; GV- bleaching with 35% hydrogen peroxide (HP) + restoration; and GVI- HP + SA + restoration. After treatments, the teeth were sectioned and decalcified. The length of resin tags and thickness of the hybrid layer were analyzed using optical microscopy (Axiophot). Results: The following results were obtained for the groups: GI- 10 and 3.1 μm, GII- 9.2 and 2.4 μm, GIII- 5.4 and 1.5 μm, GIV- 6.8 and 2.1 μm, GV-5.7 and 1.6 μm, GVI-7.1 and 2.1 μm (length of resin tags and thickness of the hybrid layer, respectively). Conclusion: Dental bleaching with CP or HP impairs the formation of resin tags and hybrid layer. The use of SA increases these measures / Mestre
54

Durabilidade da resistência adesiva entre uma cerâmica feldspática e cimento resinoso : efeito do tipo de adesivo e do cimento resinoso /

Vanderlei, Aleska Dias. January 2008 (has links)
Orientador: Luiz Felipe Valandro / Banca: Luiz Felipe Valandro / Banca: Marco Antonio Bottino / Banca: Roberto Ruggiero Braga / Resumo: O objetivo do trabalho foi avaliar o efeito de diferentes adesivos e da ciclagem térmica / armazenagem na adesão entre uma cerâmica feldspática e três cimentos resinosos (fotopolimerizável, dual e químico). A hipótese é que quanto menor o pH do adesivo, mais baixa é a resistência adesiva, especialmente na cimentação com cimento resinoso quimicamente ativado. Noventa blocos (6 x 6 x 4mm) de cerâmica feldspática microparticulada (Vita VM7) foram confeccionados. A superfície cerâmica foi tratada com ácido fluorídrico 10%/20 s e silanizada (Porcelain Primer, Bisco). Então, os diferentes adesivos foram aplicados conforme as recomendações do fabricante (Scotchbond Multi-Purpose Plus Adhesive [SBMP], pH = 5,6; Single Bond [SB], pH = 3,4; Prime & Bond NT [PBNT], pH = 1,7). Após, os blocos tratados foram reposicionados em moldes de silicone individuais e os cimentos resinosos (CR) foram aplicados (fotopolimerizável (Variolink base, Ivoclar Vivadent); dual (Variolink base + catalizador, Ivoclar Vivadent); químico (C&B, Bisco)). Assim, nove grupos foram constituídos (N=10 espécimes por grupo): (1) PBNT + CR químico, (2) PBNT + CR dual, (3) PBNT + CR foto, (4) SB + CR químico, (5) SB + CR dual, (6) SB + CR foto, (7) SBMP + CR químico, (8) SBMP + CR dual, (9) SBMP + CR foto. Os espécimes foram armazenados em água destilada (37°C) por 24 h e então seccionados no sentido x e y, a fim de obter corpos de prova (cp) em forma de barras com área adesiva de ±1mm2. Os cp de cada bloco foram aleatoriamente divididos em 2 condições de armazenagem: Seco- ensaio imediato; TCarmazenagem 150 dias (37oC) + ciclagem térmica (12.000x, 5°C-55°C). Considerando os 3 fatores do estudo (adesivo [3 níveis], cimento resinoso [3 níveis] e armazenagem [2 níveis]), foram constituídos 18 grupos (fatorial 3x3x2). O teste de microtração foi realizado numa máquina de ensaio universal... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of different adhesives and of the thermal cycling / storage (TC) on the bond strength of resin cement (RC) (photo/dual/self-cure) to a feldspathic ceramic. The hypothesis is as lower the pH of the adhesive, the lower the bond strength, especially in the cementation with resin cement chemical. Ninety blocks (6 x 6 x 4mm) (N=90) of the feldspathic ceramic (VM7-VITA) were made according to the manufacturer's recommendations. The ceramic surface was conditioned with hydrofluoric acid 10% (Dentsply) for 20 s + silane (Porcelain Primer, Bisco). Three adhesives (Scotchbond Multi-Purpose Plus Adhesive (SBMP, 3M ESPE; pH = 5.6); Single Bond (SB, 3M ESPE; pH = 3.4); Prime & Bond NT (PBNT, Dentsply; pH = 1.7)) were applied. After, three RC with different cure were applied: Photo (Variolink II base, Ivoclar Vivadent); Dual (Variolink II base + catalyst, Ivoclar Vivadent); self-cured (C&B, Bisco). Therefore, nine groups were constituted (N=10 specimens for group): (1) PBNT + RC chemical, (2) PBNT + RC dual, (3) PBNT + RC photo, (4) SB + RC chemical, (5) SB + RC dual, (6) SB + RC photo, (7) SBMP + RC chemical, (8) SBMP + RC dual, (9) SBMP + RC photo. The specimens were stored (37°C/24h) and then sectioned (adhesive area: ± 1 mm²). The specimens of each block were random divided in 2 aging conditions: Dry- microtensile test after cutting; TC- storage 150 days (37oC) + thermo-cycling (x12.000, 5°C-55°C). Considering 3 factors of the study (adhesive [3 levels], resin cement [3 levels] and aging [2 levels]) (factorial 3x3x2), 18 testing groups were composed. The tensile bond strength test was carried in a universal testing machine (cross-head speed: 1 mm/min). The 3-way ANOVA showed that the results of the bond strength were affected by the factors adhesive (P=0,0001) and resin cement (P=0,0003)... (Complete abstract, click electronic access below) / Doutor
55

Avaliação da citotoxicidade transdentinária dos sistemas adesivos universais

Santos, Andressa Fabro Luciano dos 21 August 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-11-25T16:31:14Z No. of bitstreams: 1 2014_AndressaFabioLucianodosSantos.pdf: 2463096 bytes, checksum: 0f94b500d050b15c1c40a228929105d3 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-26T11:09:56Z (GMT) No. of bitstreams: 1 2014_AndressaFabioLucianodosSantos.pdf: 2463096 bytes, checksum: 0f94b500d050b15c1c40a228929105d3 (MD5) / Made available in DSpace on 2014-11-26T11:09:56Z (GMT). No. of bitstreams: 1 2014_AndressaFabioLucianodosSantos.pdf: 2463096 bytes, checksum: 0f94b500d050b15c1c40a228929105d3 (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade transdentinária de sistemas adesivos universais sobre cultura primária de células pulpares. Setenta discos de dentina foram obtidos de dentes terceiros molares humanos íntegros e divididos em sete grupos considerando sua condutância hidráulica. Os discos foram montados em câmaras pulpares artificiais e sob sua superfície pulpar, foram cultivadas células por 48 horas. Os grupos foram definidos da seguinte forma: G1 - controle (PBS), G2 - convencional de 3 passos (Adper™ Scotchbond™ Multi-purpose); G3 - autocondicionante de passo único (Clearfil™ SE3 Bond); G4 e G5 - autocondicionante de passo único e convencional de 2 passos, respectivamente (Scothbond™ Universal); G6 e G7 - autocondicionante e convencional de 2 passos, respectivamente (Peak® Universal Bond). Decorridos 24 horas, foram avaliados o metabolismo celular pelo teste do MTT e a morfologia pela MEV. O meio de cultura em contato com as células foi coletado e utilizado para análise de morte celular utilizando o sistema de imagem celular GE InCell Analyzer 2000. Os dados foram avaliados pelos testes não-paramétricos de Kruskal-Wallis seguido do teste comparativo de Mann-Whitney (p<0,05). Todos os sistemas adesivos testados reduziram a porcentagem do metabolismo celular, comparados com o grupo controle. Os mais citotóxicos foram os grupos G5 e G2. Os grupos G2, G3, G4, G5, G6 e G7 reduziram o metabolismo em 33,7%, 19,2%, 16,83%, 42,27%, 28,83% e 8,86%, respectivamente. O potencial citotóxico dos adesivos foi G5 > G2 > G6 > G3 > G4 > G7. O G6 produziu o efeito mais fraco de indução de morte por apoptose nas células da polpa, por outro lado, os grupos G2 e G7 resultaram nos maiores valores (16,58% e 15,03%), respectivamente. A maior porcentagem de necrose foi induzida pelo grupo G2 (63,44%), sendo esta estatisticamente diferente de todos os grupos, exceto para o G4. Morte celular por necrose foi o tipo mais prevalente induzida pelos adesivos estudados. Todos os sistemas adesivos testados causaram morte (apoptose e necrose), lesão celular e alterações de morfologia, o que indica potencial citotóxico para as células pulpares. ______________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate the transdentinal cytotoxicity of universal adhesive systems using pulp cells culture. Seventy dentin disks were obtained from intact human third molars and divided into seven groups considering their hydraulic conductance. The disks were adapted on artificial pulp chamber and cells were seeded over their pulpal surface. After 48 hours, the chambers were inverted and the adhesive procedures were performed according to the groups: G1 - control (PBS), G2 – etch-and-rinse 3 step (Adper ™ Scotchbond ™ Multi-purpose); G3 – self-etch single step (Clearfil ™ SE3 Bond); G4 and G5 – etch-and-rinse single step and self-etch 2 steps, respectively (Scothbond ™ Universal); G6 and G7 – etch-and-rinse and self-etch 2 steps, respectively (Peak Universal Bond ®). After 24 hours, cell metabolism was evaluated by MTT assay and morphology by SEM. The culture medium in contact with the cells was collected and used to analyze death cell using the system image GE Incell Cell Analyzer 2000. Data were analyzed by non-parametric Kruskal-Wallis test followed by comparison Mann-Whitney (p <0.05). All adhesive systems reduced the percentage of cell metabolism compared with the control group. The lowest value of SDH production was observed for G5, followed by G2. The reduction of cell metabolism were of 33.7%, 19.2%, 16.83%, 42.27%, 28.83% and 8.86% for G2, G3, G4, G5, G6 and G7, respectively. The cytotoxic potential of the adhesive systems were G5> G2> G6> G3> G4> G7. G6 produced the weakest effect of inducing cell death by apoptosis. On the other hand, G2 and G7 groups produced the highest values (16.58% and 15.03%), respectively. The highest percentage of necrosis was induced by G2 (63.44%), statistically different from all groups, except from the G4. Necrotic cell death was the most prevalent type of cell death for all adhesives tested. All adhesive systems caused cell death (apoptosis and necrosis), reduction of cellular metabolism and alterations on cell morphology, indicating their cytotoxic potential for pulp cells.
56

Avaliação da resistência de união de sistemas adesivos à dentina saturada com água ou etanol

Guimarães, Leandro Afonso 18 December 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2009. / Submitted by Shayane Marques Zica (marquacizh@uol.com.br) on 2011-06-28T17:41:43Z No. of bitstreams: 1 2009_LeandroAfonsoGuimaraes.pdf: 833040 bytes, checksum: 75f5cf8223c6e84f037d0f03daf98c72 (MD5) / Approved for entry into archive by Guilherme Lourenço Machado(gui.admin@gmail.com) on 2011-06-29T15:22:05Z (GMT) No. of bitstreams: 1 2009_LeandroAfonsoGuimaraes.pdf: 833040 bytes, checksum: 75f5cf8223c6e84f037d0f03daf98c72 (MD5) / Made available in DSpace on 2011-06-29T15:22:05Z (GMT). No. of bitstreams: 1 2009_LeandroAfonsoGuimaraes.pdf: 833040 bytes, checksum: 75f5cf8223c6e84f037d0f03daf98c72 (MD5) / O objetivo geral deste estudo foi o de avaliar a resistência de união (RU) de sistemas adesivos que empregam condicionamento ácido total à dentina, utilizando-se a técnica úmida com água ou a técnica úmida com etanol. A superfície oclusal de vinte terceiros molares extraídos foi preparada removendo-se o esmalte oclusal junto a superfície esmalte-dentina. A superfície dentinária foi exposta e condicionada com ácido fosfórico a 37% por 15 sec, seguida de lavagem abundante e secagem com papel absorvente. A superfície foi mantida úmida (técnica úmida com água) ou saturada com etanol a 100% por 30 seg. (técnica úmida com etanol). Em seguida foram aplicados os sistemas adesivos de acordo: grupo 1: Adper Single Bond 2-SB (técnica úmida com água); grupo 2: Adper Single Bond 2-SB (técnica úmida com etanol); grupo 3: Scotchbond Multipurpose Plus-SBMP ( técnica úmida com água) e grupo 4: Scotcbond Multipurpose Plus-SBMP (técnica úmida com etanol) seguindo a recomendação do fabricante. Foi construída uma coroa de resina composta pela técnica incremental. Após 24 horas de armazenamento em água destilada em estufa (37°C), os espécimes foram preparados para o teste de microtração. Os dados obtidos da RU foram submetidos à análise de variância (ANOVA) a dois critérios (Adesivo x Técnica), seguido do teste de Tukey (p< 0,05). Não houve interação entre adesivo e técnica empregada ( p=0,597).O sistema adesivo SB apresentou maior valor de RU em ambas as técnicas empregadas,úmida com água ou úmida com etanol, comparado ao SBMP (p<0,05). Os resultados não mostraram diferenças estatísticas significantes entre as técnicas para ambos os sistemas adesivos empregados (p>0,05). Estudos adicionais empregando a técnica úmida com etanol , avaliando a longevidade ,utilizando sistemas adesivos comerciais são necessários. _______________________________________________________________________________ ABSTRACT / This study examined the immediate resin-dentin bond strength of etch-and-rinse adhesives bonded to acid-etched dentin saturated with water or ethanol. The occlusal one-third of the crown was removed from twenty unerupted human third molars; a uniform smear layer was created with 600 grit SiC. The dentin surface was acid-etched, left moist and saturated with water (water wet-bonding) or ethanol (ethanol wet-bonding). The total-etch adhesives used were: group 1: Adper Single Bond-SB (water wet-bonding) ; group 2: Adper Single Bond-SB (ethanol wet-bonding); group 3: Adper Scothbond Multipurpose-SBMP (water wet-bonding) or group 4: Adper Scothbond Multipurpose-SBMP (ethanol wet-bonding).These adhesives were then applied to both water-and-ethanol saturated dentin according manufacturer’s direction. Resin composite buildups were constructed incrementally. After storage in water for 24h at 370, the specimens were prepared for microtensile bond strength (μTBS) testing. Data were analyzed by two-way ANOVA and Tukey Multiple comparison test (p<0.05). There was not a statistically significant interaction between adhesive and technique (p = 0.597). The highest bond strength values were observed to SB for both water and ethanol-wet-bonding technique (p<0.05). For both adhesives there was not difference in bond strength values for water and ethanol-wet bonding (p>0.05). The adhesive SB performed better for overall conditions tested compared to SBMP. The ethanol-wet bonding promoted similar immediate bond strengths compared to water-bonding for both adhesives. Further investigations are needed using ethanol-wet bonding to test a long- term bond strengths.
57

Avaliação da Citotoxicidade dos Adesivos Adper™ Single Bond 2, Single Bond™Universal e Silorano Autocondicionante em Células Vero em Cultura

Catunda, Raisa Queiroz 31 January 2014 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-04-08T19:09:06Z No. of bitstreams: 2 DISSERTAÇÃO RAISA QUEIROZ CATUNDA.pdf: 1302963 bytes, checksum: 19093f5f0f4d3fbf5a39dcf14f6805a1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-08T19:09:06Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO RAISA QUEIROZ CATUNDA.pdf: 1302963 bytes, checksum: 19093f5f0f4d3fbf5a39dcf14f6805a1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar, in vitro, a citotoxicidade de três adesivos dentinários (Adper Single Bond 2 -SB, Sistema Adesivo Silorano-SAS e Single Bond Universal -SBU) em células Vero, após diferentes tempos de contato. Métodos: As células foram cultivadas a uma concentração de 2x105 células/ml por 24h e crescidas até formar uma monocamada subconfluente. As células Vero foram expostas a 25μl de extratos obtidos da imersão dos adesivos em meio de cultura (DMEM) por 24h, 48h e 72h, imediatamente após a polimerização. DMEM fresco foi utilizado como controle negativo e o metabolismo celular foi avaliado pelo método MTT [3-(4,5- Di-metiltiazol-2-il)-2,5- brometo difenil- tetrazolio)]. Os dados foram comparados estatisticamente através do teste ANOVA. Resultados: Os valores percentuais de viabilidade variaram de 94,2% em 72h (SBU) até 109,6% em 48h (SB). A média percentual de viabilidade após a exposição aos extrados de SB, SAS e SBU foram 103,2%, 100,63% e 97,43%, respectivamente. Não houve uma diferença significativa entre os grupos experimentais e o controle negativo (p= 0,342). Conclusões: Todos os adesivos testados neste estudo apresentaram nenhuma citotoxicidade à células Vero in vitro.
58

Influência de diferentes fontes de luz e distâncias de ativação no grau de conversão e propriedades mecânicas de sistemas adesivos / Influence of different light sources and distances of light curing tip on the degree of conversion and mechanical properties of dental adhesive systems

Gaglianone, Lívia Aguilera, 1985- 17 August 2018 (has links)
Orientador: Giselle Maria Marchi Baron / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T23:11:15Z (GMT). No. of bitstreams: 1 Gaglianone_LiviaAguilera_M.pdf: 1613279 bytes, checksum: 151e990585e268deef7fdff242461689 (MD5) Previous issue date: 2011 / Resumo: O objetivo do presente trabalho foi avaliar a influência de diferentes fontes de luz e distâncias de ativação no grau de conversão (GC) e nas propriedades mecânicas (módulo de elasticidade - ME e resistência à flexão - RF) de cinco sistemas adesivos (Scotchbond MP Plus - SBMP; Single Bond 2 - SB2; One-up Bond F Plus - OUP; Clearfil Protect Bond - CP, e P90 System Adhesive: primer - P90P e adesivo - P90B). Para realização dos testes, no experimento 1, as amostras de cada sistema adesivo foram divididas em três grupos (n=5), de acordo com as distâncias de ativação (2, 4 e 6 mm), enquanto que, no experimento 2, os espécimes foram divididos em dois grupos (n=5), dependendo da fonte de luz utilizada: halógena de quartzo-tungstênio (QTH) ou luz emitida por diodo (LED). Todos os adesivos foram fotoativados por 10s, exceto OUP cujo tempo de polimerização foi aumentado para 30s. Para avaliação das propriedades mecânicas, foram confeccionadas barras (7 mm X 2 mm X 1 mm) a partir de matrizes de silicone. Após 24 horas, o teste de três pontos foi realizado em Máquina de Ensaio Universal, com velocidade de 0,5 mm/min. O GC dos espécimes foi mensurado através do espectrômetro de raios infra-vermelhos transformada de Fourier (FTIR) e calculado comparando os espectros não-polimerizados e polimerizados dos sistemas adesivos. Os dados obtidos para ambos os experimentos foram analisados estatisticamente através de ANOVA 2-critérios e teste de Tukey (p?0,05). No experimento 1, avaliando GC, SB2, P90P e OUP (10s) mostraram diferença significante entre as distâncias testadas. Em todas as condições experimentais, SB2 obteve os melhores resultados de GC e OUP (10s), os piores valores. Contudo, analisando ME e RF, o melhor desempenho foi observado para o SBMP e P90B aos 2, 4 e 6 mm; SB2 foi inferior a todos os demais adesivos. Não houve diferença entre as distâncias de ativação para RF. No experimento 2, SB2, P90P e OUP (30s) mostraram melhor GC com QTH, já com LED, SB2 e P90P obtiveram os piores resultados de GC. Apenas P90B e OUP (30s) não apresentaram diferença estatística entre as fontes de luz. Avaliando ME, somente SBMP e CP mostraram significância estatística entre QTH e LED, enquanto que não houve diferença entre as fontes de luz para RF. Adesivos hidrófobos (SBMP, CP e P90B) obtiveram melhores valores de ME e RF, independentemente da fonte de luz testada. Dessa forma, pode-se concluir que o grau de conversão e as propriedades mecânicas dos sistemas adesivos são influenciados pelos fatores "distâncias de ativação" e "fonte de luz". Entretanto, essa interferência no comportamento do material depende da composição e características de cada sistema adesivo / Abstract: The aim of the present study was to evaluate the influence of different light curing units (LCUs) and distances of light curing tip on the degree of conversion (DC) and mechanical properties (elastic modulus - E and flexural strength - FS) of five adhesive systems (Scotchbond MP Plus - SBMP; Single Bond 2 - SB2; One-up Bond F Plus - OUP; Clearfil Protect Bond - CP, and P90 System Adhesive: primer - P90P and bond - P90B). To perform the tests, in experiment 1, samples of each adhesive were divided into three groups (n=5), according to light tip distance (2, 4 and 6 mm), whereas, in experiment 2, specimens were divided into two groups (n=5), depending on LCU evaluated: quartz tungsten halogen (QTH) and blue light emitting diode (LED). All adhesive systems were irradiated for 10s, except for OUP which had its activation time increased to 30s. For evaluation of mechanical properties, specimens were prepared using bar silicon molds (7 mm X 2 mm X 1 mm). After storage for 24h, the three-point flexural test was performed, at a crosshead speed of 0,5 mm/min, using a universal testing machine. DC was measured using Fourier Transform infrared spectroscopy (FTIR) and it was calculated by comparing the polymerized and unpolymerized spectra obtained from adhesive resins. The data were statistically analyzed (p?0.05) using a two-way ANOVA and Tukey's test. In experiment 1, DC was affected by distances of light curing tip and adhesive system. The distances were statistically significant for SB2, P90P and OUP (10s). For all distances tested, SB2 showed the best DC values and OUP (10s), the worst ones. However, for E and FS, better performance was obtained for SBMP and P90B at 2, 4 and 6mm, while SB2 presented the lowest values. For FS, there was no difference between distances tested. In Experiment 2, DC was also affected by LCUs and adhesive system. SB2, P90P and OUP (30s) showed better DC values for QTH, and with LED, SB2 and P90P presented the worst ones. Only P90B and OUP (30s) were not statistically significant among LCUs. For E, only SBMP and CP showed difference between QTH and LED, whereas, for FS, there was no difference among light sources. Non-solvated adhesives (SBMP, CP and P90B) presented the best E and FS values, regardless of light sources tested. It can be concluded that DC and mechanical properties of adhesive systems are influenced by factors "distances of light curing tip" and "light sources". Nevertheless, this interference is material dependent / Mestrado / Dentística / Mestre em Clínica Odontológica
59

Avaliação da adaptação à dentina de vários agentes de proteção com ou sem sistemarestaurador adesivo, em função de diferentes tratamentos da superfície dentinária. / Evaluation of the marginal finishing of cavity preparations in relation to different instrumentation methods.

Margareth da Silva Coutinho 05 April 2000 (has links)
Este estudo quantificou micrometricamente o índice de adaptação à dentina (presença ou ausência de fenda interfacial) de vários agentes protetores à base de hidróxido de cálcio de ativação química - Dycal e de luz visível - Prisma VLC Dycal e Ultra-Blend® plus e cimento de ionômero de vidro convencional - Ketac Bond e fotoativado - Vitrebond; associados a diferentes tratamentos de superfície dentinária, com e sem a presença de sistema restaurador adesivo (Primer & Bond 2.1 + TPH Spectrum). Os tratamentos dentinários foram jatos de ar/água, condicionamento com ácido poliacrílico a 25% por 10s e ácido fosfórico a 37% por 15s. Foram utilizados 200 dentes, os quais numa metade foi desgastado o esmalte e os preparos realizados em dentina e na outra metade repetiu-se o preparo cavitário envolvendo esmalte e dentina. Cavidades tipo classe V foram realizadas com 3mm de diâmetro e 0,8mm de profundidade em dentina e 0,8mm quando envolvido o esmalte. Após o preenchimento da cavidade, os corpos-de-prova foram incluídos em resina epóxica e seccionados longitudinalmente no sentido vestíbulo-lingual. Foram obtidas réplicas em negativo utilizando-se material de moldagem à base de polivinil siloxana (Aquasil), para a avaliação da desadaptação à dentina, por meio de microscópia de luz refletida em campo escuro. Os dados obtidos microscopicamente foram submetidos aos Testes de Kruskal-Wallis e as comparações múltiplas pelo Teste de Dunn. Os resultados demonstraram que quando comparados o comprimento e a largura da desadaptação à dentina dos agentes protetores, entre as condições experimentais com e sem a presença do sistema restaurador adesivo, o cimento de ionômero de vidro fotopolimerizável Vitrebond obteve os melhores resultados, sobrepujando, inclusive, o Ketac Bond ativado quimicamente. Numa posição intermediária vêm o Ultra-Blend® plus e o cimento de hidróxido de cálcio auto-ativado Dycal e, por último, o cimento de hidróxido de cálcio fotopolimerizável Prisma VLC Dycal, que apresentou a maior desadaptação. / The present study evaluated the length and width of interface gaps between dentin and the following lining materials: chemically cured Dycal Advanced Formula II and light cured Prisma VLC Dycal and Ultra-Blend® plus calcium hydroxide bases; chemically cured Ketac Bond and light cured Vitrebond glass ionomer cements. Dentin cavities prepared in human teeth were pre-treated with only an air/water Spray or with a 25% Polyacrylic acid solution for 10s, or a 37% Phosphoric acid solution for 15s. One half of cavities were prepared in dentin (3mm wide, 0.8mm deep) and have been filled with only the linning materials. The other half of the cavities were enamel dentin cavities had a 0.8mm with enamel layer, 3mm wide, 0.8mm deep below the dentinoenamel junction. Theses cavities received a layer of lining material have then been treated with an adhesive system an restored with a composite resin. In order to access the dentinal interfacial adaptation, the specimens were sectioned longitudinally in buccal to lingual direction thorough the center of the restorations. Low viscosity polyvinyl siloxane impression material (Aquasil) was used to obtain negative replicas. The replicas were examined with a Zeiss Photomicroscope and the length and width of the gaps were measured. The values were submitted to Kruskall Wallis Test and Multiple Comparation Dunn Test. Results demonstrated that, on the experimental conditions used, the glass ionomer cements obtained the best results, specially the Vitrebond. The Ultra-Blend plus and Dycal, showed an intermediary position. Prisma VLC Dycal showed the powerest adaptation.
60

Influência da fonte de luz fotoativadora na resistência de união e na micromorfologia da interface adesiva de restaurações de resina composta - Um estudo 'in vitro' com microscopia de fluorescência / Influence of light-curing sources on bond strength and on interfacial micromorphology of resin composite restorations – a fluorescence microscopy study

Paulo Henrique Perlatti D'Alpino 07 April 2005 (has links)
Propôs-se avaliar a influência de diferentes fontes de luz fotoativadoras na micromorfologia e na resistência de união adesiva de restaurações de resina composta. Selecionaram-se terceiros molares hígidos que receberam preparos cavitários classe I (6,0 mm x 4,5 mm; 2,5 mm profundidade). A resina composta (Filtek Z250 - RC) foi inserida em incremento único após a aplicação e polimerização do sistema adesivo (Adper Single Bond - SB). Os materiais restauradores foram fotoativados com os seguintes aparelhos: XL 3000 (QTH: 540 mW/cm2); Elipar FreeLight 2 (LED: 750 mW/cm2) e Arc Light IIM (PAC: 2.130 mW/cm2). Nove grupos experimentais foram avaliados de acordo com as combinações de fonte de luz para fotoativar SB/RC: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Para a análise da micromorfologia foi utilizada microscopia de fluorescência (Laser de Fóton Duplo), sendo que um corante fluorescente vermelho (Rodamina B) foi adicionado ao sistema adesivo. Além disso, utilizou-se uma solução de corante fluorescente verde (Dextran- Fluoresceína), que foi aplicada na câmara pulpar durante 4 horas, para que se difundisse em direção à interface. Os dentes foram então lavados, incluídos, seccionados e analisados microscopicamente. Os parâmetros analisados foram: espessura da camada de adesivo, espessura e qualidade da camada híbrida, micropermeabilidade, qualidade e habilidade de selamento dos tags de resina e, ainda, localização e extensão de fendas. Para o teste de resistência adesiva, os dentes foram restaurados, de acordo com as combinações de fonte de luz, e armazenados por 24 horas a 37 °C. Em seguida os dentes foram seccionados e submetidos ao teste de microtração. Realizou-se ainda a análise dos parâmetros de cinética de conversão de monômeros (conversão total, taxa máxima de conversão, conversão na máxima taxa, tempo em que ocorreu a máxima taxa e relação conversão na máxima taxa/conversão total) em um espectrofotômetro de raios infravermelho, ao qual foram aplicados os mesmos materiais restauradores que foram polimerizados com as diferentes fontes de luz. Para as avaliações qualitativas foi realizado o teste estatístico Kruskal-Wallis e o teste de Dunnet para comparações múltiplas (&#945; = 0,05). Para as avaliações quantitativas foi realizada análise de variância e teste de Tukey para comparações múltiplas (&#945; = 0,05). Da análise dos resultados, observou-se que as fontes de luz utilizadas influenciaram nos parâmetros de cinética de conversão de monômeros. De forma geral, ocorreu uma relação inversa entre a conversão total e a densidade de potência quando se polimerizou o sistema adesivo. Na resina composta base, houve uma relação direta. Para ambos os materiais houve uma maior taxa máxima de conversão, em um menor tempo, proporcional à densidade de potência dos aparelhos. Quanto aos parâmetros de micromorfologia, não se observou diferença siginificante entre os grupos experimentais em relação à espessura e qualidade de camada híbrida. Em relação à espessura da camada de adesivo, observaram-se maiores espessuras quando o sistema adesivo foi polimerizado com o PAC. Para a micropermeabilidade, também não se observou diferença entre os grupos. Também, não se observou diferença siginificante em relação à qualidade e habilidade de selamento dos tags de resina. Em relação à presença de fendas, quando o PAC polimerizou o sistema adesivo, menores porcentagens de piores escores e menores extensões de fendas foram observadas. A combinação PAC/QTH apresentou valores significantemente maiores de resistência adesiva e LED/QTH, as menores. A espessura da camada de adesivo, localização de fendas e resistência adesiva foram significantemente influenciados pela fonte de luz que polimerizou o sistema adesivo, sendo que, quando o PAC foi utilizado, melhores resultados foram observados. As combinações de mesma fonte de luz apresentaram, de forma geral, resultados similares. As diferentes fontes de luz fotoativadoras influenciam na resistência de união adesiva e em alguns parâmetros da micromorfologia da interface de restaurações de resina composta. / The purpose of the present in vitro study was to evaluate the effect of different light-curing sources on interfacial micromorphology and on bond strength of resin composite restorations. Class I preparations (6.0 mm long, 4.5 mm wide, 2.5 mm deep) were made in extracted human third molars, after abrading cusps, following university approved HAC guidelines. Restorations were placed in bulk, using a dentin bonding agent (DBA) / resin composite (RC): Adper Single Bond / Filtek Z250. Restoratives were light-cured as follows: XL 3000 (QTH: 540 mW/cm2); Elipar FreeLight2 (LED: 750 mW/cm2); Arc Light II (PAC: 2,130 mW/cm2). Nine experimental groups were developed from the different light combinations with respect to curing the DBA/COMP: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Fluorescing agent (Rhodamine B) was added to the DBA, highlighting the bonded interface and surrounding structures. A different colored dye (FTIC-Dextran) was placed in the pulp chamber for 3 hours, allowing time to diffuse toward the different-colored interface. The teeth were then embedded, sectioned, and microscopically analyzed using fluorescence microscopy (Two-Photon Laser) at 40x magnification. Micromorphology quantitative and qualitative evaluations were: quality and thickness of hybrid layer; micropermeability test, adhesive layer thickness; quality and sealing ability of resin tags; location and extension of gaps. For bond strength test, the same experimental groups were obtained. After restorative procedures, the teeth were stored in distilled water for 24 h at 37 °C. After this time period, resin layers were added to the restoration surface (providing same dentin/resin length), and then sectioned and subjected to microtensile test in a universal testing machine. Kinetics conversion parameters were also evaluated in an FT-IR spectrophotometer (total conversion, maximum rate of cure, time when maximum rate occurred, conversion at maximum rate, conversion at maximum rate/ total conversion ratio). The same restorative materials were applied to the ATR device, attached to the spectrophotometer, and then polymerized according to manufacturer’s instructions. Data was statistically analyzed as mentioned below. Statistical analyses revealed that different light sources influenced the kinetics conversion (one-way ANOVA, p< 0,05). It was found an inverse relation between power density and monomer conversion when polymerizing DBA. For resin composite (bottom), there was a positive relation between power density and total conversion. High intensity, broad banded PAC light produced higher maximum rate of cure (in %/s), in shorter times. In terms of micromorphology, no significant difference was found in terms of quality and thickness of hybrid layer (two-way ANOVA, p> 0.05). No significant difference was noted for in quality and in sealing ability of tags (Kruskal Wallis, p> 0.05). QTH/QTH presented higher percentages of best scores for both parameters. Adhesive layers were found to be significantly thicker when PAC light was used to polymerize DBA. Even thought it was also found no significance in micropermeability scores (Kruskal Wallis, p> 0.05), it was found higher percentage of best scores for control QTH/QTH. Photo-polymerizing DBA using PAC produced lower incidence of gap formation, irrespective of RC curing source. Combination PAC/QTH presented significantly higher bond strength and LED/QTH, the lower (two-way ANOVA, Dunnet’s pos-hoc test, p< 0.05). Part of interfacial micromorphology parameters and bond strength were more dependent on the photo-polymerization source used for dentin-bonding agent than for resin composite. Photo- polymerizing DBA using PAC produced best results for adhesive thickness, gap location, and bond strength. Although QTH/QTH, LED/LED, and PAC/PAC combinations produced similar general results, it was found inherent characteristics when analysing tested parameters. Different light curing units influence bond strength and some parameters of micromorphology.

Page generated in 0.1112 seconds